AHB Auto Half Barrier Circuit Based on MKII installation
|
|
- Della Hudson
- 5 years ago
- Views:
Transcription
1 AHB Auto Half Barrier Circuit Based on MKII installation This document is not endorsed by Network Rail. It is NOT for installation, commissioning, testing or maintenance purposes, it is for information only. Network Rail s own documents must be followed at all times, however; this contains re-written extracts from railway standards. Copyright F. M. Spowart Version One May 2015
2 AHB Auto Half Barrier Circuit Page Two of Six Treadles (strike-in) to ensure TC occupies IBJ s A B Track circuit Treadle (exit A/B ) Use the basic track layout above with the following flowchart: THESE STYLE BOXES DESCRIBE THE FUNCTION OF THE RELAY THESE STYLE BOXES DESCRIBE THE SEQUENCE OF OPERATION THESE STYLE BOXES DESCRIBE WHAT IS HAPPENING AT LC & SB REPEAT RELAY OF TPR & TR (TRACK CIRCUIT OCCUPIED/CLEAR) STRIKE IN TC STICK RELAY. DROP WITH STRIKE IN TC. WILL NOT REPICK UNTIL EXIT CONDITIONS MET/TIME RELEASE ACTIVATED/OR BARRIERS RAISED USING LCU 10 SECOND TIMER RELAYS. THESE DROP WHEN STRIKE-IN TC OPERATED AND THEN START TO TIME. THIS IS TO ENSURE BARRIERS ACTIVATE AT THE CORRECT DISTANCE TRAIN OCCUPIES TRACK CIRCUIT A A T1PR DROPS A TPSR DROPS A SR PICKS AFTER 10 SECONDS, 1 & 2 TJR S DROP SIGNALLER RECEIVES WORKING INDICATION FOLLOWS JCSR, IF TJR s DON T PICK WITHIN 3 SECS OF EACH OTHER, THIS RELAY WILL PICK TJPSR DROPS COMPARES TIME OF TJR s AND IF 3 SECS DIFFERENCE IT WILL RE- PICK THEM DROPS (CON)JPR AFTER 7.5 SECONDS AFTER AMBER LIGHTS HAVE LIT CUTS FEED OFF TO BARRIER VALVES (CON)JR DROPS AFTER 7.5 SECS (CON)JPR DROPS (CON)SR DROPS AFTER 3 SECONDS HJR DROPS HJPR DROPS RED ROAD LIGHTS SHOW JCSR PICKS AMBER LIGHTS SHOW YODALS SOUND TIMER RELAY ENSURES AMBER ROAD LIGHTS SHOW FOR 3 SECONDS DROPPING ACTIVATES RED ROAD LIGHTS. IT CAN ONLY RE-PICK IF BARRIERS ABOVE 42 DEGREES AND RE-DROPS IF EJR DROPS SEE NEXT PAGE (A) SEE NEXT PAGE (B)
3 AHB Auto Half Barrier Circuit Page Three of Six FROM PREVIOUS PAGE (A) FROM PREVIOUS PAGE (B) BARRIERS FALL BELOW 81 DEGREES RECR PICKS PROVES THE AMOUNT OF ROAD LIGHTS LIT. (UP)KR DROPS SWITCHES ON BOOM LIGHTS BOOM LIGHTS ILLUMINATE IF SUFFICIENT LAMPS ARE LIT IF INSUFFICIENT LAMPS LIT ONE LEFT HAND LAMP OUT ON A POST TOGETHER WITH A RIGHT LAMP OUT ON ANOTHER POST WILL CAUSE THIS RELAY TO REMAIN DE-ENERGISED TO INDICATE LAMPS FAILED TO TECHNICIAN RECPR PICKS BARRIERS FALL BELOW 4 DEGREES RECPR REMAINS DE-ENERGISED SEQUENCE WILL CONTINUE, BUT BARRIERS WILL NOT RAISE AFTER TRAIN HAS PASSED EJR PICKS (SEE LATER) (DN)KR PICKS PROVES BOTH BARRIERS HAVE COMPLETED DESCENT, AND PROVIDES ONE FEED TO EJR TRAIN STRIKES EXIT TREADLE THEN DROPS APPROX 7 SECONDS AFTER LAST PRESS OF ARM A/B QRR PICKS A/B QRSR PICKS & STICKS REGISTERS TREADLE ARM PRESSED REPEAT STICK RELAY OF QRR TRAIN OCCUPIES TRACK CIRCUIT B REPEAT RELAY OF TPR & TR (TRACK CIRCUIT OCCUPIED/CLEAR) B T1PR DROPS B TPSR DROPS EXIT TC STICK RELAY. DROPS WITH EXIT TC. WILL NOT REPICK UNTIL FULL EXIT CONDITIONS MET/TIME RELEASE ACTIVATED/OR BARRIERS RAISED USING LCU TRAIN CLEARS TRACK CIRCUIT A A T1PR PICKS (SEE T1PR ABOVE) SEE NEXT PAGE
4 AHB Auto Half Barrier Circuit Page Four of Six FROM PREVIOUS PAGE A TPSR PICKS A/B QRSR DROPS YODALS TURNED OFF (CON) SR PICKS* HJR PICKS *ONLY IF RECPR PICKED EARLIER JCSR DROPS (CON)JR PICKS (CON)JPR PICKS EJR DROPS & STARTS TIMING TIMER THAT RE-STARTS SEQUENCE IF BARRIERS DO NOT RAISE WITHIN 7.5 SECONDS FROM (CON)JPR DROPPING STICKS (CON)JR BARRIERS RISE ABOVE 4 DEGREES (DN)KR DROPS VALVES & MOTORS ENERGISED IF (UP)KR FAILS TO PICK IN 7.5 SECONDS, EJR WILL DROP HJPR AND RE-ILLUMINATE RED ROAD LIGHTS BARRIERS RISE ABOVE 15 DEGREES HJPR PICKS RED LIGHTS EXTINGUISH RECR DROPS BARRIERS RISE ABOVE 81 DEGREES BARRIERS RISE ABOVE 83 DEGREES RECPR HELD BY HJPR MOTOR FEED CUT OFF & VALVES CLOSED HOLD BARRIERS UP TRAIN CLEARS TRACK CIRCUIT B SEE NEXT PAGE
5 AHB Auto Half Barrier Circuit Page Five of Six FROM PREVIOUS PAGE IF EXIT TRACK FAILS TO CLEAR THEN A/B JR WILL START TIMING, WILL THEN PICK A/B JPR AND AFTER 120 WILL RESTART SEQUENCE UNTIL THE TRACK CLEARS B T1PR PICKS B TPSR PICKS A SR DROPS SIGNALLER RECEIVES RAISED INDICATION NOTE: IF STRIKE-IN TRACK CIRCUIT FAILS WITHOUT PRESENCE OF A TRAIN, THE SEQUENCE WILL BE INITIATED AND BARRIERS WILL REMAIN DOWN. WHEN THE TRACK CLEARS, THE A/B JR WILL START TO TIME OUT AND PICK A/B JPR, RAISE BARRIERS AND RESTORE BARRIERS RAISED INDICATION. THIS WILL HAPPEN IF TRACKS WERE TESTED ON MAINTENANCE UNLESS THE LC WAS TAKEN ON LOCAL CONTROL, THEN LCU UP CIRCUIT WILL MAINTAIN (CON)SR STICK PATH. Indication to the signalbox is sent via either three or four wire operation. Three wire uses a common negative, and the other two wires used for raised and power off indication. No voltage gives working indication. With four wire operation both the negatives are maintained all the time. Only the positive uses one of the two other wires for raised power on and the other wire for raised power off, no voltage gives working indication to the signaller. Relay normal positions when crossing normal (barriers raised): Relay UP Relay DOWN A T1PR A SR A TPSR B SR B T1PR A/B QRR B TPSR A/B QRSR (LCU)DOOR CR A/B JR (Y/Z)CR (BARRIER DOORS) A/B JPR (LCU) (N) CSR (NOT ON LOCAL CONTROL) (DN)KR (PO)PR (POWER ON) JCSR (UP)KR EJR 1 TJR RECR 2 TJR (CON)SR HJR HJPR
6 AHB Auto Half Barrier Circuit Page Six of Six Relay UP (CON)JR (CON)JPR RECPR TJPSR Relay DOWN Relays not mentioned in flowchart above: (CON)YR ZCSR TZSR TZJR (UP) QRCSR or (DN)QRCSR (NS)R (NS)SR (DWL)R (DWL)ECR Combines the directional controls for all four approaches on double-line bi-directional AHB s. Prevents sequence of road lights if LCU lower/hand switch is turned with barriers up and either pedestal door open or Y/Z(DOOR)CR has failed. Track special relay used for a berth track for a regulated signal. Once dropped it requires overrun track circuit occupied or a treadle activated. It is used to prevent a train disappearing due to rusty rails. Timer used for above relay. Used in conjunction with QRSR, it proves the treadle for direction it states has been normalised after passage of a train Non-stopping train repeat of button in SB Stick relay for above Drivers white relay Drivers white light proving relay Differences between Mark I and Mark II installations: Mark One Penguin style pedestal mounted on a concrete pillar, with metal framework, hydraulic power pack with hoses. Removable top and bottom very flimsy plastic covers (called guillotine covers). LCU inside one of the pedestals, with push buttons and lever over auto button. Road lights and bells (later Yodals) fixed to same concrete post as the pedestals. Barrier booms made from wood. Barrier weights inside pedestals. Earlier installations had neon Another Train Coming signs (later abolished). Telephones to signalbox inside flap on pedestals. Relay (CON)R used. ECR s used in light circuits. Mark Two One piece steel 843 type pedestal with two hinged access doors and microswitch on handle side. Contains sealed hydraulic power pack. But better weather protection compared with a Mark One. LCU in post near one of the pedestals containing three-position switch. All four road lights have their own post. Two yodals fixed to two posts. Barrier booms made from tubular metal. Barrier weights on end of barriers. Another Train Coming signs are metal retro reflective type. Telephones on their own posts. Relay changed to a stick relay [(CON)SR] RECR relays used. The circuitry between both varies with some relays abolished/added. >>>END<<<
Morwell. (88 miles 75 chains 47 links, km)
Morwell (88 miles 75 chains 47 links, 144.372 km) 01.06.1877 Opened with line between Morwell and Sale. Staff and Ticket not provided initially. (VR to 62, Leo Harrigan, WTT) (01.04.1878) By this date,
More informationSomerton SOMERTON (13 MILES 42 CHAINS)
Somerton SOMERTON (13 MILES 42 CHAINS) Somerton has had four phases of existence. The first, from 1881 to 1889, was as a simple passenger platform which served the village of Somerton on Sydney Road. Between
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE4120 AUTO MAINS FAILURE MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel:
More information5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL
5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL > Section DSE Model 5220 Automatic Mains Failure & Instrumentation System Operators Manual TABLE OF CONTENTS
More informationMODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM
MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5110 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5220 AUTO MAINS FAILURE MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel:
More informationPSM72H Push-Button Start Module
Capricorn Controls DA02PSM72H1-2 Data & Application Note Page 1 of 6 PSM72H Push-Button Start Module Genset Controls - Timers/Monitors/Trips - Battery Charging Spares & Accessories - Custom Products Ultra
More informationHWP Protection Board
February 2009 HWP Protection Board Features and Operation This board provides the system protection features necessary to keep our HWP (Water Sourced Heat Pump) units safe in the instances when they are
More informationTable Of Contents. Motor Selection Guide Installation Instructions Operators 20-32
Table Of Contents Motor Selection Guide 2-12 - Shades, Shutters and Doors - Retractable Awnings Installation Instructions 13-1 - Operator Adaptors - Operator Limit Adjustment - Wiring Considerations -
More informationKV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: High Voltage AC Test Set KV3-250 mk2 KV4-300 mk2 KV5-100 mk2 KV5-100T mk2 KV5-200 mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge
More informationModel 2300JL Installation Guide
Model 2300JL Installation Guide POWER ACCESS CORPORATION 4 HERSHEY DRIVE, DOCK 4 ANSONIA, CT 06401 800-344-0088 WEBSITE: www.power-access.com EMAIL: salesinfo@power-access.com 1 STANDARD PARTS MODEL 2300JL
More informationModel 2300DL Installation Guide
Model 2300DL Installation Guide POWER ACCESS CORPORATION 4 HERSHEY DRIVE, DOCK 4 ANSONIA, CT 06401 800-344-0088 WEBSITE: www.power-access.com EMAIL: salesinfo@power-access.com 1 STANDARD PARTS MODEL 2300DL
More informationOUTDOOR UNIT CONTROLLER (OUC)
AUCKLAND temperzone Ltd 38 Tidal Road, Mangere, Auckland. Private Bag 93303, Otahuhu, N.Z. Phone 0-9-279 5250 Fax 0-9-275 5637 Email sales@temperzone.co.nz WELLINGTON Phone 0-4-569 3262 Fax 0-4-566 6249
More informationRemote Engine Starter System I User s Information Manual
Remote Engine Starter System I User s Information Manual A Few Words About Safety Your safety, and the safety of others, is very important. Operating this Remote Engine Starter System safely is an important
More informationOperator Manual. Transfer Switch. RSS100 and RSS Cummins Inc. All rights reserved. English
Operator Manual Transfer Switch RSS100 and RSS200 English 8-2007 962 0134 Table of Contents SECTION TITLE PAGE SAFETY PRECAUTIONS................................................... ii 1. INTRODUCTION.........................................................
More informationOperating Instructions Pedestrian Turnstile Type MPT 33
Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11
More informationHGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL
HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL SMARTGEN ELECTRONICS Smartgen Electronic Equipment Co., Ltd No.12 Dongqing Street Zhengzhou Henan Province P.R.China Tel : (0086)-371-67992951
More informationHitachi EAS Air Compressor Piston Seal Repair Kit Instructions
Hitachi EAS Air Compressor Piston Seal Repair Kit Instructions Introduction Is your vehicles air suspension rising slowly, noisily, or perhaps failing to rise at all? EAS Amber light lit, Fault code C1A20,
More informationMANUAL. Note: If the charger indicates START POWER VOLTAGE CHECK PROGRAM lamp and BAD lamp press MODE-button for 2 sec to exit VOLTAGE CHECK PROGRAM.
MODE VOLTAGE CHECK PROGRAM BATTERY START POWER ALTERNATOR MXS 5.0 CHECK BY MANUAL CONGRATULATIONS on the purchase of your new professional switched mode battery charger and battery check instrument. This
More informationCentralised Traffic Control System - Rules 1 to 17
Centralised Traffic Control System - Rules 1 to 17 Applicability VIC Publication Requirement External Only Document Status Issue/Revision # Effective from 2 13 May 2012 0 04 October 2015 Australian Rail
More informationApplication Examples Nano ICCS with Toggle Function
Nano ICCS with Toggle Function Fog lamp controller for vehicles integrated into the PCB Fog lamp must be turned on with an impulse signal. The fog lamp can be activated or deactivated via switch, which
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE704 AUTOSTART CONTROL MODULE OPERATING MANUAL 057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR - 1 - Deep Sea Electronics Plc
More informationStart Up Instructions for the Kiln, Page 1 of 2
Start Up Instructions for the Kiln, Page 1 of 2 1. Turn the Main Breaker at the right side of the panel on. 2. Press the orange [Control Power On] push button. It will light up when pressed. 3. If the
More informationMANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES MV600
MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES MV600 TABLE OF CONTENTS PART I GENERAL DESCRIPTION... PAGE 2 PART II FUNCTIONS... PAGE 2 PART III INSTALLATION... PAGE 3 PART IV INITIAL INSTALLATION
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE710 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44
More informationXCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY
Reso-not TM Damping System XCITE Owner s Manual 1502C HYDRAULIC POWER SUPPLY Xcite Systems Corporation 675 Cincinnati RDS Batavia - 1 Pike Cincinnati, Ohio 45245 Tel: (239) 980-9093 Fax: (239) 985-0074
More informationPROPORTIONAL BAND ZERO ENERGY BAND DEFINITION S1 S2
Honeywell T0C INDIVIDUAL ROOM TEMPERATURE CONTROLLER INSTALLATION GUIDE Cover removal Mounting T0C 00-00 R Wiring T0C.mm (max) Remote Temperature Sensor Screen wire 0 Connect screen wire to terminal or
More informationDeep Sea Electronics Plc
Deep Sea Electronics Plc 5120 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL Author: Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH England Tel: +44 (0) 1723
More informationFire Fighting Diesel Pump Control Panel in Compliance with EN Standard User Manual
Fire Fighting Diesel Pump Control Panel in Compliance with EN 12845 Standard User Manual Electronic Control Panel Display Panel door-lock Control Buttons Siren Figure 1. Diesel Control Panel - External
More informationCambridge International Examinations Cambridge International General Certificate of Secondary Education
www.xtremepapers.com Cambridge International Examinations Cambridge International General Certificate of Secondary Education *2641043214* DESIGN AND TECHNOLOGY 0445/43 Paper 4 Systems and Control October/November
More informationFunction of residual engine heat utilization system
83-300 Function of residual engine heat utilization system Operation No. of Operation Texts and Work Units, Standard Texts and Flat Rates: F10 Auxiliary fuse holder, residual engine heat utilization system
More informationTAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B)
TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B) TECHNICAL MANUAL v1.3 JANUARY 2014 Technical Manual (Updated 6 th January 2014) No Vehicle timer Vehicle delay timer Overrun timer
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE720 AUTOSTART CONTROL MODULE OPERATING MANUAL http://bestgenerator.spb.ru/?page_id=6765 Deep Sea Electronics Plc Highfield House Hunmanby North
More information4.2 Component Identification
Digital Control Panels Deep Sea Electronics 5220 4.1 General 4.2 Component Identification 4.3 The YML5220 Controller 4.4 Description of Controls 4.5 Navigation 4.5.1 General Navigation 4.5.2 The Event
More informationCONTROLLER DIAGNOSTIC GUIDE
Proprietary tice: This document contains proprietary information which not to be reproduced, transferred, to other documents, disclosed to others, used for manufacturing or any other purpose without the
More information. OPERATING INSTRUCTION MANUAL NO. 548-A
WABCO ~. OPERATING INSTRUCTION MANUAL NO. 548-A SATELLITE LOCOMOTIVE REMOTE CONTROL SYSTEM. I,t UNION SWITCH & SIGNAL DIVISION Westinghouse Air Brake Company PITTSBURGH.PA. 15218 SepteITiber, 1963 Al.63-250-848.2
More informationVehicular Swing Gate Operator. Nice. Titan 912L. The Titan 912L Gate Operator is intended for use with vehicular swing
Vehicular Swing Gate Operator Nice Gate Operators Titan 912L The Titan 912L Gate Operator is intended for use with vehicular swing gates. The Titan 912L Gate Operator can be used in Class I, Class II and
More informationVEHICLE AND PEDESTRIAN CONTROL
VEHICLE AND PEDESTRIAN CONTROL Jacksons design and manufacture a wide range of gates in steel, timber or a combination of both to safe guard the continued security of any installation. Regardless of the
More informationWarrenheip WARRENHEIP (69 MILES 56 CHAINS 80 LINKS VIA BACCHUS MARSH)
Warrenheip WARRENHEIP (69 MILES 56 CHAINS 80 LINKS VIA BACCHUS MARSH) 01.02.1873 Open for passengers on Geelong - Ballarat line (Chronological Index) (31.12.1878) By this date, open for general goods (Commissioners
More informationCommercial Vehicle Trip Inspection Schedule School Bus
Accessibility devices Air brake system Alternating overhead lamps (if the vehicle is required to be equipped with them by a law of Manitoba or Canada or by school authority policy, or if there is evidence
More informationUser Instruction manual for Cardale Autoglide
User Instruction manual for Cardale Autoglide NOTE TO INSTALLER: This user manual is supplied for the instruction of the end user. It contains important safety and warranty information. This manual MUST
More informationOwner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR
ECA Electronic Engineering Pty. LTD. Australia Tel: 03-95720 535 Fax: 95 720 536 Owner s Manual For SOLAR BOOM GATE Model: CA-5000 SOLAR ( 2009 / Version 1 ) 1 1 Introduction 1.0 Control PCB Wiring INSTALLATION
More informationTranax Error Code Summary
Tranax Error Code Summary Citywide ATM is in no way liable for the misinterpretation of the error codes herewithin, nor are we responsible for hardware that is ordered to fix a machine problem, without
More informationREVISED ATM72 Auto Transfer Module
Capricorn Controls DA01ATM1-1 Data & Application Note Page 1 of 8 REVISED - - - ATM72 Auto Transfer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom
More informationSYSTEM OPERATION IMPORTANT CAUTIONS
SYSTEM OPERATION The system is turned on by placing the gear shift lever in the reverse position. The green light on the cab Control Box will illuminate to indicate the system is operating. When an object
More informationNEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977
NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977 1. GENERAL. 1.1 These PR notes supersede notes PR 2133 and should only be used in conjunction with
More informationBroadmeadows BROADMEADOWS (10 1/2 MILES)
Broadmeadows BROADMEADOWS (10 1/2 MILES) Broadmeadows is situated at the top of the long climb out of the Moonee Ponds Creek valley. It served the established communities of Keilor (to the west) and Campbellfield
More informationRE5R05A. Technical Bulletin # Computer Diagnostics
Transmission: Subject: Application: Issue Date: Computer Diagnostics Nissan, Infinity July, 2008 Computer Diagnostics There are two separate controller systems that are used for the transmission applications.
More informationSDM72 Start on Demand Modules
Capricorn Controls DA04SDM72-2 Revised Design Page 1 of 6 SDM72 Start on Demand Modules Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products Application
More informationSmartON / SmartON+ Installation and Use Manual
SmartON / SmartON+ Installation and Use Manual Rev. Date Ver. Ver. Notes document document SmartON SmartViewII 1.0 06/04/2007 3.08 2.30 Pre-release 1.01 10/04/2007 3.08 2.30 Release 1.02 04/10/2007 3.09
More informationDo isolate the power supply from other high power systems such as Stereos and Alarms
Thank you for purchasing a Smart Ride Air Management System, AIRBAGIT.COM s premier flagship product. This system will meet all of your custom and utility needs and will provide you years of trouble free
More informationMRG Series Railway Crossing Swing Gate
MRG Series Railway Crossing Swing Gate Page 1 Operation, Installation and Maintenance Instructions Barriers - Pedestrian MRG / Railway Gate Section CONTENTS Description Page 1.0 Safety Precautions 2 2.0
More informationPBS M Marine Push Button Start
PBS M Marine Push Button Start INSTALLATION & USER GUIDE PBS M CONTENTS The following list of components are included in this system: 1 Push Button Start & RFID Reader 1 PBS Harness Pack 1 RFID Antenna
More informationZTC 335 Dual Track Detector Installation Manual
ZTC 335 Dual Track Detector Installation Manual WARNING If you fail to read the installation instructions properly it is possible that you could accidentally damage your ZTC unit. Such damage is NOT covered
More informationAutomatic drain valves
driving commercial vehicles If you notice more than a few drops of water when you drain the supply reservoir, the air dryer or compressor may need servicing. fast fact Even if the air brake system includes
More informationProduct Campaign Bulletin
Nissan Ireland Cedar House Park West Business Park Nangor Road, Dublin 12 Product Campaign Bulletin REFERENCE: MODEL: PIB-NES-EC-14-009 J11 Qashqai SUBJECT: PIB J11 - P1655 and P1656 Stop - Start System
More informationInstallation & Programming Guide
Installation & Programming Guide EMTouch & EMTouch Classic Style Electronic Lever Locksets EMTouch EMTouch Classic Style ASSA ABLOY, the global leader in door opening solutions What s in the Box 4a 4b
More informationFire control. Electromagnetic fire Door Retainers. Available Models
2 Fire control Electromagnetic fire Door Retainers - Operating Voltage: 24Vdc or 240Vac - Holding Force: 55kg or 140kg - Tested and certified to EN 1155 and CE marked - Surface mounts to standard BS wiring
More informationDigital Room Thermostats with Touch Screen LCD
TC40 Touch Series Digital Room Thermostats with Touch Screen LCD Revision Date February 22, 2013 Features Wall-mount Display Control to match any decor Extra large easy-to-read Liquid Crystal Display (LCD),
More informationKing Air B90. Speeds (KIAS)
King Air B90 Speeds (KIAS) V MCA 92 V SSE (101) Derived from C90 V X 101 V Y 114 Down to 103 @ 30 000 V XSE 101 V YSE 110 Down to 101 @ 24 000 V A 169 V R 92 V 1 101 V MO 208 V FE 174 35% 130 100% V LE
More informationLocomotive Driver Desk. Manual
Locomotive Driver Desk Manual Authors: Dr.-Ing. T. Vaupel, D. Richter, M. Berger Translated by Wolfram Steinke Copyright Uhlenbrock Elektronik GmbH, Bottrop 3rd Edition March 2004 All Rights Reserved Duplication
More informationRS-230-DP. Operation Guide
RS-230-DP Deluxe Keyless Entry & Remote Start July 27, 2010 Operation Guide Temporary cover. Color cover is in a separate file. Table Of Contents Introduction...2 The Transmitter...3 Transmitter Functions...3
More informationMaintenance notice proceeding
Maintenance notice proceeding When check, remove and replace car body electric relating parts, please pay attention to the proceedings below. 1. Lighting There is sealed gas in halogen bulb, so please
More informationATA 49 AUXILIARY POWER UNIT
F900EX EASY 02-49-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-49 02-49-00 TABLE OF CONTENTS 02-49-05 GENERAL Introduction Sources APU location 02-49-10 DESCRIPTION Introduction Description Operating principle
More informationOptimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version
Optimal Series Automatic Transfer Switch Installation and User Manual for the OPT2225 Automatic Transfer Switch Full Version File: OPT2225 Rev2.5.doc November, 2004 2 Thank You For Purchasing This DynaGen
More informationFC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE
FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE SENS part number: 101037 Document revision: A Engineering change number: 105073 Date: 1/13/2006 1840 Industrial Circle
More informationTE-HUD User Manual. l ::: J TECH SUPPORT. MetraDealer.com
TE-HUD User Manual ibeamusa.com MetraDealer.com techsupport@metra-autosound.com TECH SUPPORT l ::: J 800-253-8324 It displays driving data on the front windshield such as speed, RPM, water temperature,
More informationIsuzu. Chapter Testing Engine and Transmission Systems Engine And Transmission Code Reading Connectors and Locations
Chapter 10 Isuzu This chapter contains information for testing Isuzu vehicles with the Asian Import Vehicle Communication Software (VCS). The following Isuzu systems may be available for testing: Engine
More informationWelcome To A&M Systems, Inc.
Welcome To A&M Systems, Inc. 1 4121 Eastland Drive Elkhart, IN 46516 Ph: 574-522-5000 Fx: 574-522-9099 Web: www.anmsystems.com 2 95+ Different Actuator Models 350+ Different Door Models 1,000s of Options
More informationTranax Error Code Summary
Error Code Definition Recommended Action 20001 Unable to load a cassette Remove and replace cassette - Check the micro-switch located on the inside left wall of the dispenser 20002 Low Cash Replenish the
More informationMODEL 422 Submersible Pump Controller
MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and
More informationInstallation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System
Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System U.S. Patent No. 7,04,050 For assistance, contact SARGENT
More informationFuse disconnectors for cylindrical fuse-links
Advantages of fuse disconnector PF + N in one module Double connection clamps New method of mounting on the DIN rail and simple replacement LED indicator version Extraction of entire fuse-link when changing
More informationSECTION B1: MACHINE COMPONENTS
SECTION B1: MACHINE COMPONENTS The machine portion of the Injected Metal Assembly system provides the means for: holding, heating and injecting the alloy; distributing and controlling electrical, pneumatic,
More informationCommercial Vehicle Trip Inspection Schedule Heavy Passenger Vehicles and Trailers
Accessibility devices Air brake system Cargo ment Coupling devices Alarm does not operate Equipment does not operate Interlock system does not operate Audible air leak Slow air pressure build-up rate Cargo
More information12 STATION MANUAL CONTROLLER INSTALLATION AND OPERATING GUIDE MODEL HRM-12
Ed Hydro Rain. 12 STATION MANUAL CONTROLLER INSTALLATION AND OPERATING GUIDE MODEL HRM-12 The HRM-12 is a 12 station controller that can be set to water from twenty-four times a day to once every two weeks.
More informationUP Series Miniature Pilot Lights
Available in Various Sizes Five illumination colors: amber, green, red, white, yellow Various sizes and design. Available with a built-in current limiting resistor. Waterproof () types available for and.
More informationMULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3
MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3 OPERATING INSTRUCTION Poka Patrol CNA-4mk3 Poka Patrol CNA-4mk3 To use this product properly and safely, please read this manual carefully before
More informationEasyStart. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual
EasyStart 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter Installation Manual Micro-Air Corporation www.microair.net 124 Route 526 Phone (609) 259-2636 Allentown NJ 08501 Fax (609) 259-6601 Retrofit
More informationInstallation and Operating Manual
MOTORS AND DRIVES SIGNAL ISOLATOR Accessory for BC204 Regenerative Drive Installation and Operating Manual 4/2000 MN1387 TABLE OF CONTENTS Section Page i. Safety Warning..........................................................
More informationAgriWheel Single Gate Kit Low Voltage & Solar. Installation & Operating Instructions
AgriWheel Single Gate Kit Low Voltage & Solar Installation & Operating Instructions Thank you for purchasing you AgriWheel system. Please remove the lids from both the machine and control box and remove
More informationN1387 Series Troubleshooting Guide for N Alternators
N1387 Series Troubleshooting Guide for N1387-1 Alternators Hazard Definitions These terms are used to bring attention to presence of hazards of various risk levels or to important information concerning
More informationEmergency lighting units EM powerled
PRO EZ-3, 4 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with LI interface and automatic test function For self-contained emergency lighting SELV for output
More informationCOMPONENT WORK SAMPLE 14 Integrated Peer Performance MAINTENANCE MANUAL
COMPONENT WORK SAMPLE 14 Integrated Peer Performance MAINTENANCE MANUAL Copyright 2003 VALPAR International Corporation P.O. Box 5767 Tucson, Arizona 85703-5767 All rights reserved. No part of this manual
More informationVehicle makes models and variants known or believed to be using this vehicle system, required diagnostic lead and degree of known compatibility.
WABCO D TYPE (P38 NRR)-System Overview This is a small black ECU which replaced the Wabco C type during the 1999 update to the P38. If the vehicle has White indicators and/ or Air Bags in the seats, it
More informationECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual
ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual Headquarters : No.3, Lane 201, Chien Fu St., Chyan Jenn Dist., Kaohsiung, TAIWAN Tel : + 886-7-8121771 Fax : + 886-7-8121775 URL : http://www.kutai.com.tw
More informationP445 Series Electronic Lube Oil Control
FANs 125, 121 s Section P Product/Technical Bulletin P445 Issue Date 0100 P445 Series Electronic Lube Oil The P445 Series Electronic Lube Oil is designed for use on refrigeration compressors equipped with
More informationInstallation/Owner s Manual 1601 / 1602
CFORMS TO ANSI/UL-325 CERTIFIED TO CAN/CSA C22.2 NO. 247 CLASS HP MODEL SERIAL 53382 VEHICULAR GATE OPERATOR DoorKing, Inc., Inglewood, CA Installation/Owner s Manual 60 / 602 Barrier Gate Operator Use
More informationNSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL
APPLICATION OF DUST CONTROL EQUIPMENT: CAUTION - Warning Improper operation of dust control system may contribute to conditions in the work area or facility that could result in severe personal injury
More informationKD LV Motor Protection Relay
1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage
More informationRemote Engine Starter System User s Information Manual BAM02767
Remote Engine Starter System User s Information Manual BAM02767 A Few Words About Safety Your safety, and the safety of others, is very important. Operating this Remote Engine Starter System safely is
More informationLAN SYSTEM SECTION LAN CONTENTS K ELECTRICAL LAN-1 LAN CAN TEM)... 19
SYSTEM K ELECTRICAL SECTION A SYSTEM B C D CONTENTS E TEM)... 19 F PRECAUTIONS... 3 Precautions for Supplemental Restraint System (SRS) AIR BAG and SEAT BELT PRE-TEN- SIONER... 3 IVMS ()... 4 Overall Description...
More informationEC500 Power Control System
EC500 Power Control System 1 Introduction This section of the handbook will guide you through the operation of the electrical system. Further technical details are contained in sections 3 to 6 or in the
More informationDEEP SEA ELECTRONICS PLC
DEEP SEA ELECTRONICS PLC 703 AUTOMATIC START MODULE OPERATING INSTRUCTIONS Author:- John Ruddock 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 1 - >
More informationSD3-60 AIRCRAFT MAINTENANCE MANUAL
AMM 11.0.0.0AUTO-FEATHERING SYSTEM - DESCRIPTION & OPERATION 1. Description A. General This system is employed to speedily reduce propeller drag by automatically feathering the propeller on an engine which
More information8803214-8803999 DIODE BOARD The diode board is located inside the lower control box. D15 D8 D7 D14 D5 D13 ART_2181 J1 14 8 D9 D10 7 1 R2 R1 R3 R4 TB1 8601 D11 D3 D12 D4 D1 D2 J1 Plug Pin Identification
More informationDIODE BOARD The diode board is located inside the lower control box. D15 D8 D7 D14 D5 D13 ART_2181 J1 14 8 D9 D10 7 1 R2 R1 R3 R4 TB1 8601 D11 D3 D12 D4 D1 D2 J1 Plug Pin Identification PIN # WIRE # SIGNAL
More informationCHAPTER 6 ELECTRICAL SYSTEMS
CHAPTER 6 ELECTRICAL SYSTEMS Page TABLE OF CONTENTS 06-00-01/02 DESCRIPTION General 06-10-01 Description 06-10-01 Controls and Indicators 06-10-02 COMPONENTS Circuit Breaker Panel Locations 06-20-01/02
More informationMAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT
Model No. PEL00582 MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT 1 Please read these instructions carefully before starting installation and retain for future reference. The centre page test record
More information