PROPORTIONAL BAND ZERO ENERGY BAND DEFINITION S1 S2

Size: px
Start display at page:

Download "PROPORTIONAL BAND ZERO ENERGY BAND DEFINITION S1 S2"

Transcription

1 Honeywell T0C INDIVIDUAL ROOM TEMPERATURE CONTROLLER INSTALLATION GUIDE Cover removal Mounting T0C R Wiring T0C.mm (max) Remote Temperature Sensor Screen wire 0 Connect screen wire to terminal or 0 ON System Switches SYSTEM & PARAMETER SELECTION SWITCHES ON OFF ON CONTROL SYSTEM PROPORTIONAL BAND ZERO ENERGY BAND DEFINITION S S DEFINITION S S Xp (system dependent) S S S ZEB S Thermo-Electric OFF ON Actuator (TPM) On / Off ON OFF Modulating ON ON Heat / Cool Changeover OFF OFF -Stage Heating + OFF ON -Stage On/Off Cooling -Stage Cooling + ON OFF -Stage On/Off Heating K ON ON ON K ON ON OFF K OFF OFF ON OFF ON ON ON OFF ON K K ON OFF Heat + Cool Sequence ON ON K OFF OFF OFF OFF ON OFF ON OFF OFF

2 MODULATING CONTROL Up to x M0C actuators (0.VA each) can be connected to each output. Maximum rating of On/off output is 00mA. A V~ contactor or relay must be used to switch higher current or voltage loads.

3 ON/OFF CONTROL Maximum rating of On/off output is 00mA. A V~ contactor or relay must be used to switch higher current or voltage loads.

4 TPM CONTROL (THERMO-ELECTRIC ACTUATORS) Maximum rating of On/off output is 00mA. A V~ contactor or relay must be used to switch higher current or voltage loads.

5 LAYOUT & TERMINAL CONNECTIONS Terminals Potentiometer System Switches Sensor Diagnostic LED. volt supply. volt supply (0v). Valve open. Valve close. Valve common. Valve open / stage on/off control (applications,,,0,,). Valve close / stage on/off control (applications,,,0,,). Heat / Cool changeover input. Heat / Cool changeover input 0. Energy savings input. Energy savings input. Remote sensor input. Remote common (for remote sensor & remote setpoint inputs). Remote setpoint input All terminals are suitable for connection of up to.mm stranded cable. STARTUP & COMMISSIONING SEQUENCE On power up, T0C will undergo a test and synchronisation sequence to enable Installers and Commissioning Engineers to test the system is wired correctly. Test Sequence For all control modes, the test sequence will last 0 seconds, and will consist of switching the control outputs on and off in the sequence illustrated below. The outputs are connected to terminals,,, and. Valve Synchronisation For modulating systems, the test sequence will be followed by a valve synchronisation (taking approximately minutes), where the valves will be driven to the closed position to establish a baseline control reference. For On/off and TPM control systems, the valve closure sequence will last 0 seconds. The synchronisation sequence will be repeated hours after power up, and thereafter every hours. The Diagnostic LED will illuminate in the sequence illustrated for Terminal below, if no faults are detected (see Section entitled Diagnostics & Fault Indication for a complete description). On/off & TPM Systems Terminal Close Valves Terminal Terminal Terminal (secs) Normal Control Only applies for On/off Heat + Cool Sequence system 0 Modulating Systems Terminal Terminal Terminal Close Valves (min approx.) Normal Control Terminal (secs)

6 DIAGNOSTICS & FAULT INDICATION T0C provides simple user diagnostics and fault indication using an LED, positioned at the bottom right side of the printed wiring board. The T0C cover can be removed to view the LED correctly. By pulsing the LED on and off in predefined sequences, T0C is able to indicate valve position, heating or cooling demand, or whether a fault has been detected. The tables and graphs opposite illustrate how to interpret the LED outputs. Fault Indication If a fault is detected, this will be indicated as a higher priority than valve position or cooling / heating demand. Faults are indicated by,, or LED pulses, followed by a second delay, then a repeat of the pulse sequence. Most detectable faults are associated with errors in reading sensor or setpoint values. In the unlikely event of an internal sensor or unit setpoint fault, the only option is to replace the complete controller. However, if a remote sensor fault is indicated, the most likely reason is a bad connection, so all wiring connections should be checked and re-made if necessary. Internal Sensor Remote Sensor Unit Fault Indication 0 0 Fault Internal Sensor out of range Remote Sensor out of range Faulty setpoint measurement Suggested Action Replace controller Check sensor connections Replace controller (secs) Diagnostics Valve Position / Cooling or Heating Demand Valve position or cooling/heating demands are indicated by an initial code sequence of pulses, followed by the position or demand data, and this is repeated on a fixed cycle rate. The duration of the data pulse provides the important information, for example : Valve position : LED on for a duration proportional to the valve position, where 0s on = valve fully open On/off or TPM demand : LED on for an amount proportional to the on period of the cycle, where 0s on = 0 demand T0C will only provide demand or position data on the current operating output, and this will be indicated by the initial pulse sequence of,, or pulses. By reference to the table, the current operating mode and demand can be determined for each of the possible control options. Valve position / Demand Valve position / Demand Valve position / Demand Output Type 0 0 (secs) Output Type 0 0 (secs) Output Type 0 0 (secs) Modulating Control On/off Control TPM Control 0 Valve closed Valve closed Valve Position Modulating Cooling Valve closed Valve closed Valve Position Modulating Heating nd Stage On/off Heating demand st Stage On/off Heating demand Valve Position Modulating Cooling+ On/off Heating nd Stage On/off Cooling demand st Stage On/off Cooling demand Valve Position Modulating Heating+ On/off Cooling Valve closed Valve Position (Cooling Operation) Valve Position (Heating Operation) Modulating Heat / Cool Changeover Valves closed Position of Cooling Valve Position of Heating Valve Modulating Cool + Heat Sequence Valve closed Valve closed Valve Demand On/off Cooling Valve closed Valve closed Valve Demand On/off Heating nd Stage On/off Heating demand st Stage On/off Heating demand Valve Demand On/off Cooling+ -Stage On/off Heating nd Stage On/off Cooling demand st Stage On/off Cooling demand Valve Demand On/off Heating+ -Stage On/off Cooling Valve closed Valve Demand (Cooling Operation) Valve Demand (Heating Operation) On/off Heat / Cool Changeover Valves closed Cooling Valve Demand Heating Valve Demand On/off Cool +Heat Sequence Valve closed Valve closed Valve Demand TPM Cooling Valve closed Valve closed Valve Demand TPM Heating nd Stage On/off Heating demand st Stage On/off Heating demand Valve Demand TPM Cooling+ -Stage On/off Heating nd Stage On/off Cooling demand st Stage On/off Cooling demand Valve Demand TPM Heating+ -Stage On/off Cooling Valve closed Valve Demand (Cooling Operation) Valve Demand (Heating Operation) TPM Heat / Cool Changeover Valves closed Cooling Valve Demand Heating Valve Demand TPM Cool +Heat Sequence

7 ENERGY SAVINGS MODE T0C has an Energy Management System, where the detection of an external input signal will cause the cooling and heating setpoints to change to pre-defi ned setup and setback temperatures, enabling maximum energy effi ciency. This input signal must be in the form of a contact closure, connected to terminals 0 and. In Mode the Setup/Setback values can be set between -K by means of an on-board potentiometer. In cooling only systems (,, ) the setpoint will be increased (setup) by the set value fi xed by the potentiometer. In heating only systems (,, ) the setpoint will be decreased (setback). In heat/cool changeover systems (,, ) the heating setpoint will be decreased in heating mode, and the cooling setpoint will be increased in cooling mode. In cooling + heating systems (,,,, 0,,,, ) the cooling setpoint will be increased by the set value and the heating setpoint will be decreased by the same amount. The effect is to widen the Zero Energy Band. Input Wiring Connections T0C 0 Switch should be rated 0 Vdc 0. ma nominal = Normal Operation = Mode ENERGY SAVINGS : EXAMPLES () Modulating Cooling Potentiometer 0 Valve position Setting K Cooling = Normal Cooling + Cooling Setup = Normal Cooling + K Example: Setup value = k Normal Temp ( C) () Modulating Heating Potentiometer 0 Valve position Setting K Heating = Normal Heating - Heating Setback = Normal Heating - K Example: Setback value = k Normal Temp ( C) () Modulating Cooling +Heating Sequence ZEB Potentiometer 0 Valve position Normal Heating Normal ZEB Normal Cooling ZEB = Normal ZEB + Heating Setback + Cooling Setup = K + K + K = K Temp ( C) Example: Setup/setback value = k Heating Cooling

8 REMOTE SETPOINT ADJUSTMENT T0C allows its setpoint to be adjusted remotely by up to ±K. This is achieved by the connection of a Remote Adjustment module to terminals and, as shown in the wiring schematic. Suitable modules are : QB0 (Remote Adjust), and QC0 (Sensor + Remote Adjust). To ensure measurement stability when wiring these modules, use screened cable, and connect the screen wire to terminal or 0 of the T0C, as shown. QB0 REMOTE SETPOINT ADJUST T0C 0 QB0 Use screened cable Screen wire QC0 SENSOR + REMOTE SETPOINT ADJUST T0C QC0 0 Use screened cable Screen wire REMOTE SENSOR T0C is supplied with an on-board temperature sensor. If remote temperature sensing is required (for example in return air sensing applications), then a suitable Honeywell Remote Sensor can be connected to terminals and as shown in the wiring schematics. T0C auto detects the Remote Sensor on power up, and will use the Remote Sensor measurement in preference to its internal sensor. The power must be switched off then on again for a remote sensor to be detected. Remote Sensors are available as wall-mounted or airfl ow (return air) models : T0C00 Airfl ow Sensor supplied with. m cable QA00 Wall-mounted Sensor QC0 Wall-mounted sensor + Remote Adjust All Remote Sensors require screened cable to be used to ensure stability of temperature measurement. The screen wire must be connected to terminal or 0 of T0C, as shown. If this cable is to be extended then the maximum cable run will be 0m, and the extension must also use screened cable. T0C 0 T0C00 SENSOR T0C00 Use screened cable Screen wire QA00 WALL-MOUNTED SENSOR T0C QA00 0 Use screened cable Screen wire AUTOMATIC HEAT / COOL CHANGEOVER If automatic or central Heat / Cool changeover is required, set both system switches S and S to the off position (see page ). Automatic changeover is initiated by a thermostat positioned on the water fl ow pipe, detecting the presence of heated or chilled water, and sending the appropriate signal to the controller. A suitable product is the S0A00 pipe-thermostat. Central changeover is initiated by a switch, and can be used to centrally switch a group of connected T0C controllers from Heating to cooling operation. See wiring schematics for connection details. Automatic Heat / Cool Changeover T0C 0 S0A00 Central Heat / Cool Changeover T0C T0C T0C Central Switch = Heating = Cooling VALVES, ACTUATORS & OPTIONAL ACCESSORIES Optional Accessories A range of optional accessories are available for use with T0C : F00-00 Range stops F00-00 Wall-plate Q0A0 Fan Speed Switching Subbase QA00 Wall mounted Remote Sensor QB0 Remote Adjust Unit (±K) QC0 Sensor + Remote Adjust Unit (±K) T0C00 Return Air Sensor (.m cable) S0A00 Pipe-mounted Changeover Thermostat Environmental Controls Honeywell Control Systems Ltd. Newhouse Industrial Estate Motherwell, ML SB Scotland honeywell R

T8078C LOW VOLTAGE MODULATING CONTROLLER FEATURES APPLICATIONS PRODUCT SPECIFICATION SHEET

T8078C LOW VOLTAGE MODULATING CONTROLLER FEATURES APPLICATIONS PRODUCT SPECIFICATION SHEET LOW VOLTAGE ODULATING CONTROLLER FEATURES PRODUCT SPECIFICATION SHEET APPLICATIONS The digital electronic controller is designed for individual zone control of terminal units in fan coil and air conditioning

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro STEP 1: Pre-Programming Preparation: Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings. If errors are detected (e.g., failed

More information

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

ZIP Economizer Fault Detection and Diagnostics (FDD) Table Fault Detection and Diagnostics (FDD) Table Fault Detection Problem Diagnostic ction (in addition to alarm stored / transmitted) Potential Cause C Fault Code OT sensor predetermined range O damper returns

More information

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB TB6980/TB7980 1. Introduction The TB6980/TB7980 digital thermostats provide proportional plus integral individual space temperature control in zoned commercial HVAC systems such as hydronic and pressure

More information

MC200CAB/4 Integral Version

MC200CAB/4 Integral Version Issue 2.2 Mar 2017 MC200CAB/4 Integral Version Industrial & Commercial Heating Systems. www.powrmatic.co.uk Setting Instructions WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Reset from Lockout is

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL Model No. DFC-X Support 877-351-4702 DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This manual covers the following products: DFC-X TS-01 DFTD RDU DAT-12 PWM-10V

More information

Flight Systems. Replacement for KASSEC DESCRIPTION

Flight Systems.   Replacement for KASSEC DESCRIPTION DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most

More information

8803214-8803999 DIODE BOARD The diode board is located inside the lower control box. D15 D8 D7 D14 D5 D13 ART_2181 J1 14 8 D9 D10 7 1 R2 R1 R3 R4 TB1 8601 D11 D3 D12 D4 D1 D2 J1 Plug Pin Identification

More information

DIODE BOARD The diode board is located inside the lower control box. D15 D8 D7 D14 D5 D13 ART_2181 J1 14 8 D9 D10 7 1 R2 R1 R3 R4 TB1 8601 D11 D3 D12 D4 D1 D2 J1 Plug Pin Identification PIN # WIRE # SIGNAL

More information

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F Starting System DS-102 Series 200 Elmatik AS P.O.Box 309 NO-3471, Slemmestad T - +47 31 28 37 83 F - +47 31 28 37 93 www.elmatik.no post@elmatik.no CONTENT 1. INTRODUCTION 3 2. TECHNICAL SPECIFICATIONS

More information

SECTION 2 - PROCEDURES. Features. 2.6 MOTOR CONTROLLER. Modes of Operation JLG Lift 2-5

SECTION 2 - PROCEDURES. Features. 2.6 MOTOR CONTROLLER. Modes of Operation JLG Lift 2-5 2.6 MOTOR CONTROLLER. Modes of Operation. 1. Traction Motor Drive. a. Drive in either forward or reverse will start only if the following conditions are satisfied: 1. Function switches off. 2. No procedure

More information

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR 24 Volt AC input Built in 15 second low fire start timer 0-24 Volt DC modulating output Remote temperature selection Calibration trim pot Rated for -40 F (-40 C) DFC-1 STANDARD TEMPERATURE CONTROL DFC-2

More information

RDG160TU Commercial Thermostat

RDG160TU Commercial Thermostat Document No. 129-588 RDG160TU Commercial Thermostat Selecting Location Install the thermostat about 4 feet (120 cm) above the floor on an inside wall. Ensure that there is free airflow around the thermostat.

More information

Digital Room Thermostats with Touch Screen LCD

Digital Room Thermostats with Touch Screen LCD TC40 Touch Series Digital Room Thermostats with Touch Screen LCD Revision Date February 22, 2013 Features Wall-mount Display Control to match any decor Extra large easy-to-read Liquid Crystal Display (LCD),

More information

Temperature Controllers

Temperature Controllers Controllers SCR Power Controllers Introduction to Silicon Controlled Rectifier (SCR) Power Controllers Features and Benefits of SCRs High reliability Because the SCR power controller is a solid-state device,

More information

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER The engine/generator controller is an integrated genset controller contained in a single, easy to install package. The controller contains a microprocessor-based

More information

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide Factory Packaged Controls OE377-26-00058 (AAON Part No. V12090) MODGAS-X Controller Table of Contents GENERAL INFORMATION... 3 Overview...3 Features...3 INSTALLATION & WIRING... 4 Supply Air Temperature

More information

LINEAR ACTUATORS INDEX

LINEAR ACTUATORS INDEX LINEAR ACTUATORS INDEX Linear actuators LMR Series LMR 01 thrust force up to 1 300 N DC motor... page 2 LMR 03 thrust force up to 6 000 N DC motor... page 3 Linear actuators ATL Series ATL 02 thrust force

More information

CM707 (UK Version) PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM707 (UK Version) PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM707 (UK Version) PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET The CM707 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It

More information

Quick Setup Guide for IntelliAg Model YP Air Pro

Quick Setup Guide for IntelliAg Model YP Air Pro STEP 1: Pre-Programming Preparation: The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference

More information

STRA-24 for chilled beams

STRA-24 for chilled beams STRA- Installation and commissioning manual STRA- for chilled beams STRA- is the room controller for the pressure independent (Pi) and constant air volume chilled beams. It is possible to set different

More information

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro STEP 1: Pre-Programming Preparation: The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference

More information

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE MEMBER GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA 01001-2907, USA LSM672 LOAD SHARING MODULE PRODUCT TECHNICAL INFORMATION PTI 4000 AUGUST

More information

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Sheet 1 of 5 Order Number Serial Number PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Issue Date Level B 27/05/1999 Initial issue. Summary of changes Due to RMS continuous product improvement policy

More information

LF Series At A Glance

LF Series At A Glance LF Series Spring Return Direct Coupled Actuator Minimum 35 in-lb Torque For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom

More information

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number ST48-WHUV.12 PID controller Order number 935.15 Wiring diagram Product description This micro-processed controller serves for temperature control at high measuring accuracy. Beside resistance sensors and

More information

DTC B0228, B0413, B0423, Or B3779

DTC B0228, B0413, B0423, Or B3779 2007 Chevrolet Silverado 1500 : Heating, Ventilation, & Air Conditioning > HVAC Systems - Manual > Diagnostic Information And Procedures > DTC B0228, B0413, B0423, Or B3779 DTC B0228, B0413, B0423, Or

More information

HWP Protection Board

HWP Protection Board February 2009 HWP Protection Board Features and Operation This board provides the system protection features necessary to keep our HWP (Water Sourced Heat Pump) units safe in the instances when they are

More information

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output TCAF Series Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output Issue Date March 1, 2018 Features Ultra slim wall-mount unit to match any décor Large easy-to-read Liquid Crystal Display (LCD), with

More information

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data TC2000 TC2001 EUROTHERM ONTROLS Two phase thyristor power switches Product data TC2000 TC2001 Thyristor power switches Compact, two phase thyristor power switches for electrical heating applications from

More information

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS?

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS? ARM V FDBK ENSURE MOTOR IS T ROTATING DURING POWER UP This fault can only happen in the first 3 seconds after power up. The processor looks at the armature voltage. The voltage needs to be near 0. Possible

More information

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V NFB4, NFB4-S, NFX4, NFX4-S On/Off, Spring Return, 4 V Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB4... NFX4...

More information

C.E. Niehoff & Co. C840D Alternator Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

C.E. Niehoff & Co. C840D Alternator Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING. C.E. Niehoff & Co. C840D Alternator Troubleshooting Guide WARNING Before troubleshooting any CEN products, the service technician should: read, understand, and agree to follow all information contained

More information

Temperature Controllers

Temperature Controllers SCR Power Controllers Introduction to Silicon Controlled Rectifier (SCR) Power Controllers Features and Benefits of SCRs High reliability Because the SCR power controller is a solid-state device, it provides

More information

Versatile and Powerful

Versatile and Powerful LM Series Direct Coupled Actuator Versatile and Powerful Minimum 45 in-lb torque in a compact package. For damper areas up to 11 sq-ft* Actuators in bold have BDCM LM Series - At A Glance LMB(X)24-3(-S)(-T)

More information

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide WARNING Before troubleshooting any CEN products, the service technician should: read, understand, and agree to follow all

More information

AA4006 Speed Sensitive Trip Unit. User Manual

AA4006 Speed Sensitive Trip Unit. User Manual AA4006 Speed Sensitive Trip Unit User Manual Software Version 2.00 Issued 01/2005 Don Controls Limited Westfield Industrial Estate Kirk Lane, Yeadon Leeds, LS19 7LX Telephone: +44 (0)845 1304946 Fax: +44

More information

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase ILLUMINATOR LV Emergency Lighting Inverter System 175VA through 750VA Illuminator Series LV Single Phase ILLUMINATOR SERIES LV The Illuminator Series LV is a 175VA-750VA fast transfer Emergency Lighting

More information

ELECTRONIC THERMOSTAT: T901

ELECTRONIC THERMOSTAT: T901 μnistδt ELECTONIC THEMOSTAT: T One contact output DESCIPTION The T series proportional thermostats are microcomputer based, proportional and integral (PI) devices with one contact time proportioning output.

More information

1 Safety instructions. 2 Device components. Dimmer push-button/2-way low voltage. Order No. : Operating instructions

1 Safety instructions. 2 Device components. Dimmer push-button/2-way low voltage. Order No. : Operating instructions Dimmer push-button/2-way low voltage Order No. : 2262 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries,

More information

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Power supply Standard voltages AC: 3-phase

More information

Polygyr -Compact Exhaust Air Temperature Controller

Polygyr -Compact Exhaust Air Temperature Controller Document No. CM1N3405E-P25 Polygyr -Compact Exhaust Air Temperature Controller Features Two outputs for heating and cooling Continuous control signal Application P control Electronic 24 Vac The RCM61.21

More information

ASYN205B Central Synchronizing Controller

ASYN205B Central Synchronizing Controller ASYN205B Central Synchronizing Controller Function 3 phase active power transducer, one auxiliary analog Genset power control Genset voltage frequency control Multi-gensets power balance control Selectional

More information

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document. General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Features and functions Power supply Standard

More information

SE8300 Series Installation Guide 24 Vac Low Voltage

SE8300 Series Installation Guide 24 Vac Low Voltage Installation Guide 24 Vac Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 2 Configurable BI/UI Universal Inputs Overview 3 Setup Screen Display 3 Terminal Identification

More information

ST Wiring diagram. Product description. Temperature controller. Order number

ST Wiring diagram. Product description. Temperature controller. Order number ST7-31.3 Temperature controller Order number 9154.12 Wiring diagram Product description The switching exits of the thermostatic controller can be programmed as -two-point controller with alarm -three-point

More information

Section 55 Chapter 6

Section 55 Chapter 6 Section 55 Chapter 6 REMOTE HYDRAULICS CONTROLLER Calibration and Fault Codes 6-12880NH TABLE OF CONTENTS REMOTE HYDRAULICS CONTROLLER CALIBRATION... 55-5 Requirements For Calibration... 55-5 Aux Set Main

More information

Softstarters. Softstarters Power electronic brakes Type PEB

Softstarters. Softstarters Power electronic brakes Type PEB Softstarters Power electronic brakes Softstarters Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB)

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

RVD110 RVD G2381en. Installation. Commissioning

RVD110 RVD G2381en. Installation. Commissioning 4 319 2788 0 G2381en en Installation Instructions District heating and d.h.w. controller RVD110 RVD130 Installation Place of installation In a dry room, e.g. the heat exchanger room Mounting choices: -

More information

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components DRA automatic stairway lighting Order-No. : 0821 00 Impulse insert Order-No. : 0336 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically

More information

BGH2UNCNTRLHT-01 Universal Hot Surface Ignition Control

BGH2UNCNTRLHT-01 Universal Hot Surface Ignition Control Installation Instructions BGH Issue Date vember 9, 2017 BGH2UNCNTRLHT-01 Universal Hot Surface Ignition Control Application The BASO Gas Products BGH2UNCNTRLHT-01 Universal Series Hot Surface Ignition

More information

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

Explanation 1 Input External Switch 2 Input Hipot Safety Switch on the 1100H+ The 1100H+ has capability, which allows you to set up the tester to control external devices with tester functions. You can also use an input on the tester to start a test. For example, the

More information

LF Series Spring Return Direct Coupled Actuator

LF Series Spring Return Direct Coupled Actuator LF Series Spring Return Direct Coupled Actuator Minimum in-lb torque LF actuator For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including:

More information

Remote Temperature Controllers. Quick Selection Guide

Remote Temperature Controllers. Quick Selection Guide Remote Temperature Controllers Quick Selection Guide A Complete Selection For A Wide Range Of Applications Electronic Standalone Controllers T775 Provide on/off, modulating, or reset control in applications

More information

General Information... 2

General Information... 2 VAV Flow Controller-Actuators CSP 5001/5002 Applications Guide General Information... 2 CSP 5001/5002 Overview...2 Controller, Sensor, and Thermostat Functions...3 Wiring...4 Air Flow Sensor Connection...4

More information

Test. What type of cylinder would you use? A. Single-acting cylinder B. Double-acting cylinder Answer:

Test. What type of cylinder would you use? A. Single-acting cylinder B. Double-acting cylinder Answer: Test This test allows you to establish whether your basic knowledge of pneumatic controls is sufficient for you to attend the advanced course P or whether you should attend the basic level course P. The

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

Constant Voltage/Constant Current Test System

Constant Voltage/Constant Current Test System Description Constant Voltage/Constant Current Test System The Constant Voltage/Current Test System may be used for constant voltage or constant current pulse testing of automotive and aerospace igniters,

More information

Electronic Ballast EVG 2000-T

Electronic Ballast EVG 2000-T Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications

More information

For installation instructions refer to the mounting and dimensions details and the terminal layout drawings on page 5 of this manual.

For installation instructions refer to the mounting and dimensions details and the terminal layout drawings on page 5 of this manual. Provisional Instruction Manual The MSSD33 suspended solids detector is a microprocessor-based instrument to detect the suspended solids/water interface in pipelines. The instrument consists of two components,

More information

Versatile and Powerful

Versatile and Powerful AM Series Direct Coupled Actuator Versatile and Powerful Minimum 180 in-lb torque in a compact package. For damper areas up to 45 sq-ft* All Actuators have BDCM AM Series - At A Glance AMB(X)24-3 (p. 148)

More information

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

ELECTRIC SCHEMATICS LS1 LS2. 1532ES / 1932ES Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243 ELECTRIC SCHEMATICS NOTES: (Unless otherwise specified). Switch S BASE/PLATFORM makes contact from the CENTER to the LEFT position when placed in BASE.. Switch S UP/DOWN makes contact from the CENTER to

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

Differential Temperature Controller

Differential Temperature Controller 3 337 Synco 100 Differential emperature Controller R27 Differential temperature controller for solar storage systems. Compact design with two 2-position control output AC 24 230 V. Use Plant types: Solar

More information

Installation and Operations Manual

Installation and Operations Manual Excalibur Water Systems 2.0 HIGH CAPACITY SUPER FLOW SERIES DUPLEX WATER SOFTENER Installation and Operations Manual 142 Commerce Park Drive, Units M-O, Barrie ON L4N 8W8 www.excaliburwater.com 2.0 High

More information

Service Bulletin Power Sliding Door Operation and Troubleshooting (Replaces , Power Sliding Door Problems, dated April 20, 1999)

Service Bulletin Power Sliding Door Operation and Troubleshooting (Replaces , Power Sliding Door Problems, dated April 20, 1999) Service Bulletin 01-051 Applies To: 1999 2001 Odyssey ALL May 8, 2001 Power Sliding Door Operation and Troubleshooting (Replaces 99-027, Power Sliding Door Problems, dated April 20, 1999) BACKGROUND The

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18) AF Series Spring Return Direct Coupled Actuator Minimum 133 in-lb torque For damper areas up to 35 sq-ft* (For lower torque, see NF, LF, or TF series) Applications Remove for 3/4 to 1.05 shafts ZG106 or

More information

Hoffman Controls. Installation & Operating Instructions. General. Installation. Determining Damper Shaft Rotation. Stop Pin Installation

Hoffman Controls. Installation & Operating Instructions. General. Installation. Determining Damper Shaft Rotation. Stop Pin Installation Hoffman Controls Installation & Operating Instructions General 1. This instruction is a guide for connecting and operating the 200-3 Series Flow Controller with the 207 Series Thermostat and the 241-2

More information

Start-Up, Operation and Service Instructions

Start-Up, Operation and Service Instructions Article I. Krueger Proportional LineaHeat W/ Discharge Temperature Start-Up, Operation and Service Instructions SAFETY NOTE Air-handling equipment will provide safe and reliable service when operated within

More information

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No Document No. 155-521 (For Use with 2-1/2-Inch to 6-Inch Pressure Independent Control Valves) Features Operating voltage: AC/DC 24V Application Control signals: 3-position, DC 0 to 10V, DC 4 to 20 ma Fail-safe

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

Visit for more technical information & downloads

Visit  for more technical information & downloads Visit for more technical information & downloads 000 00 005 009 010 011 012 013 01 No faults Warning: Short circuit in control box, fresh air output Warning: Short circuit in control box, car alarm output

More information

PRODUCT INFORMATION BULLETIN

PRODUCT INFORMATION BULLETIN 724-283-4681 724-283-5939 (fax) PRODUCT INFORMATION BULLETIN DESCRIPTION The, Model 10-7100 is one in a series of critical speed switches that monitor speed and detect motion in all types of machinery

More information

G2515. Installation. Place of installation. Electrical installation. Permissible cable lengths. Securing the controller to the base

G2515. Installation. Place of installation. Electrical installation. Permissible cable lengths. Securing the controller to the base 74 319 726 G2515 en Installation Instructions District heating controller for 2 heating circuits and d.h.w. RVD26 Keep these instructions with the controller! Installation Place of installation In a dry

More information

DRC Travel Drive Control Application Software

DRC Travel Drive Control Application Software Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service DRC Travel Drive Control Application Software RE 9 0/06.06 replaces: 0.0 Technical data sheet Electronic

More information

Crompton Controls. This is. Installation and Maintenance Instructions. S10 & Smooth-BRAKE DC Injection Brake Modules. Tel: +44 (0)

Crompton Controls. This is. Installation and Maintenance Instructions. S10 & Smooth-BRAKE DC Injection Brake Modules. Tel: +44 (0) This is Crompton Controls Installation and Maintenance Instructions S0 & Smooth-BRAKE DC Injection Brake Modules LT0 Issue Tel: + (0)9 8 DC Injection Brake Module Installation and Maintenance Document

More information

FSAF24(-S) US, FSAF120(-S) US

FSAF24(-S) US, FSAF120(-S) US FSAF4(-S) US, FSAF10(-S) US On/Off, Spring Return, Meets 50 F [11 C] for Half Hour, 75 Seconds Torque min. 133 in-lb, for control of air dampers Technical Data FSAF4(-S) US, FSAF10(-S) US Power supply

More information

Engineering Bulletin. IntelliPak RTM (Rooftop Module, 1U48) Subject: Generic Building Automation System (GBAS, UCM Module, 1U51)

Engineering Bulletin. IntelliPak RTM (Rooftop Module, 1U48) Subject: Generic Building Automation System (GBAS, UCM Module, 1U51) Engineering Bulletin IntelliPak RTM (Rooftop Module, 1U48) Subject: Generic Building Automation System (GBAS, UCM Module, 1U51) Issued By: Clarksville Marketing and Sales Support Order No. UN-PRB001-EN

More information

TRIPS AND FAULT FINDING

TRIPS AND FAULT FINDING WWW.SDS.LTD.UK 0117 9381800 Trips and Fault Finding Chapter 6 6-1 TRIPS AND FAULT FINDING Trips What Happens when a Trip Occurs When a trip occurs, the drive s power stage is immediately disabled causing

More information

J1 Plug Pin Identification

J1 Plug Pin Identification D5 D8 D7 D4 D5 D ART_8 J 4 8 D D0 7 R R R R4 TB 80 D D D D4 D D J Plug Pin Identification PIN # WIRE # SIGNAL FUNCTION 0 INPUT Drive Reverse INPUT Drive Forward OUTPUT Brake, Decel Valve signal 4 8 INPUT

More information

System 350 P352AB Electronic Pressure Control Series

System 350 P352AB Electronic Pressure Control Series System 350 P352AB Electronic Pressure Control Series System 350 Product Guide 930 Basic Controls Section Product/Technical Bulletin P352AB Issue Date 0200 The P352AB controls are On/Off electronic pressure

More information

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD General information AC 01.2 Actuator controls in SIL version for controlling multi-turn actuators of the SA/SAR.2 type range and part-turn actuators of the SQ/SQR.2 type range. Information on SIL features

More information

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + - Instruction Manual Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + - Optional - Switch to disconnect solar panel when engine alternator

More information

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview. 11 or 14mm drive output (Option)

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview. 11 or 14mm drive output (Option) Feature rich J+J multi-voltage smart electric actuator with LED status light and function conversion kits. J3C-S85 Overview The J3C-S85 multi-voltage electric valve actuator from the electric actuator

More information

SAX Electronic Valve Actuator

SAX Electronic Valve Actuator SAX Electronic Valve Actuator Non-spring Return, 24 Vac, Proportional Control Technical Instructions Document No. 155-506 Description The SAX Non-spring Return (NSR), Electronic Valve Actuator requires

More information

Injector Solenoid - Test

Injector Solenoid - Test Injector Solenoid - Test System Operation Description: Use this procedure to troubleshoot the electrical system if a problem is suspected with the injectors or if any one of the diagnostic codes in Table

More information

OUTDOOR UNIT CONTROLLER (OUC)

OUTDOOR UNIT CONTROLLER (OUC) AUCKLAND temperzone Ltd 38 Tidal Road, Mangere, Auckland. Private Bag 93303, Otahuhu, N.Z. Phone 0-9-279 5250 Fax 0-9-275 5637 Email sales@temperzone.co.nz WELLINGTON Phone 0-4-569 3262 Fax 0-4-566 6249

More information

Metasys Zoning Package Installation

Metasys Zoning Package Installation Technical Bulletin Issue Date August 28, 2002 Metasys Zoning Package Installation Metasys Zoning Package Installation...2 Introduction... 2 Key Concepts... 3 Installation Overview... 3 Metasys Zoning Package

More information

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING. C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide WARNING Before troubleshooting any CEN products, the service technician should: read, understand, and agree to follow all information

More information

LF24-ECON-R03(-R10) US Operation, Installation and Wiring

LF24-ECON-R03(-R10) US Operation, Installation and Wiring LF24-ECON-R03(-R0) US Operation, Installation and Wiring Operation LF24-ECON-R03(-R0) US The LF24-ECON-R03(-R0) US provides a direct coupling solution for RoofTop Unit(RTU) economizer dampers. Control

More information

V200 V200. Control on water, proportional integral. Simplified Master / Slave operation GENERAL DESCRIPTION

V200 V200. Control on water, proportional integral. Simplified Master / Slave operation GENERAL DESCRIPTION Master Slave 1 Slave (n + 1) Master Slave 1 Slave (n + 1) Simplified Master / Slave operation GENERAL is a CIAT electronic control system designed to control non-independent air conditioning terminal units

More information

P445 Series Electronic Lube Oil Control

P445 Series Electronic Lube Oil Control FANs 125, 121 s Section P Product/Technical Bulletin P445 Issue Date 0100 P445 Series Electronic Lube Oil The P445 Series Electronic Lube Oil is designed for use on refrigeration compressors equipped with

More information

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions with 2-way push switch with 2-way push switch Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the actuator out. If it rotates

More information