Precision-I Laboratory System Universal Digital Monitor

Size: px
Start display at page:

Download "Precision-I Laboratory System Universal Digital Monitor"

Transcription

1 Precision-i Digital Monitor DM-A1 is a revolutionary monitoring device that cater to critical environment applications in Fume Hood control, Laboratory controls, Isolation Room controls and Vivariums controls.it comprises of 3 universal input for monitoing of critical parameters such as temperature, humidity, pressure and fedback from airflow devices. It has 3 digital output that enable it to control stage heaters, airtight dampers and lightings. It 2 analogue outputs enables it to control airflow devices, SCR heaters and lightings intensity in the critcal environment as stated above. Hardware Specifications Inputs 3 Programmable Universal Inputs, 12bit resolution, Supports 0-10Vdc,4-20ma DC, 10K theristor input, Dry contact. Outputs Digital 3 Programmable Digital Output 1 Amp Rated Outputs Analogue 2 Programmable analogue Output, 10bit resolution, Supports 0-10Vdc,4-20ma, 0-5Vdc Power Requirement 5Va,+/- 50Hz, Maximum power consumption 5W Deminsions 83 mm x 160 mm x 50 62mm x 44mm Blue LCD ( Viewable Area) Operating Environment 0-50 Degree Ceilus 10%-90% RH( Non Condensing) Pressure Sensor Specification Specifications Silicon Diaphragm Accuracy Zero Point +/- 0.02%FS Linearity +/- 0.5%FS Sensitvity +/- 0.06%FS Responseime <10 ms Pressure Ranges +/-0.25 mbar (0.1 W.C) +/- 0.5 mbar (0.2 W.C) +/- 1.0 mbar (0.4 WC) Pressure orlerance 100mbar over pressure tolerance 200mbar rupture Contact Factory for Other Pressure Ranges Integration Protocol Modbus F-10 compliant with Lontalk Conformance o Standard Electronics : CE Software/Firmware: LonMark Complant

2 Vpot Master V-Pot emperature Input Pressure Switch RM Pressure Switch EA RM Pressure Switch SA Pressure Switch EA Control Signal( Master ) Heater SCR control Signal Stage Heater OutPut Precision-I Laboratory System Hospital Application Differential Pressure Sensor Air ight Damper Isolation Room Monitor Decon Mode Closes All AD Dampers Air ight Damper Valve Controller Stage Heater O/P or 4-20 ma SCR control O/P Venturi Valves Air Venturi Valves Patient Room Lonalk 3.2 Lonalk 3.2 Air ight Damper Air ight Damper Room Room Differential Pressure Switch Stage Heater O/P or 4-20 ma SCR control O/P Differential Pressure Switch Room Refer o Detail 1 for Network Detail Alarm : Dry Contact to Nurse Call Station Fire Mode Receive set all valves to emergency consitions( By Others) Isolation Room / Intensive Care Unit he above application shows DM-A1 Universal Monitor being configured to control the critical Environment in Isolation Room and Intensive Care Unit. his monitor can be flush mount to the wall on these rooms and provide the following parameter for monitoring purposes through 3 universal inputs on the monitor. hey are as following emperature of room Differential Pressure of Room Humidity Alarms he universal monitor also caters 3 digital outputs that can be used to control heaters and air tight dampers under decontamination conditions. hese air tight dampers can only be activated to close when a password is entered under decontamination conditions. In addition, all alarms conditions will activate a third DO to inform the Nurse Call station of critical conditions in these room. Finally, there are two analogue outputs that are 4-20 ma and or 0-10Vdc to control air flow devices in the room to maintain proper air change and pressure regime

3 Laboratory Application Laboratory Control racking Pair Solutions Differential Pressure Sensor Air Venturi Valves Stage Heater Output Universal Input RH Volumetric Control With Differential Pressure Fine uning ( Casading Control ) Feedback FH General Air Venturi Valves Laboratory Control Inverse Gex Solutions General Venturi Valves 4-20 Ma control output for supply / air device control CV Fan Flow = Fume Hood + General Fume Hood Monitor Control Signal FH V-Pot Input Sash Input( Ai) Dry Contact Input (BMS Control E- Mode) Sash Sensor Fume Hood Air Venturi Valves

4 Control Vpot Master Signal( Master ) V-Pot 1 V-Pot 2 emperature Input Pressure Switch RM Heater SCR control Signal Pressure Switch EA RM Pressure Switch SA Pressure Switch EA Stage Heater OutPut Precision-I Laboratory System Laboratory Application Laboratory Control Animal Virarium Animal Vivarium Application Differential Pressure Sensor Air ight Dampers Air ight Dampers Valve Controller Stage Heater O/P or 4-20 ma SCR control O/P Venturi Valves Air Venturi Valves Lonalk 3.2 Air ight Dampers Lonalk 3.2 Animal Holding Room Refer o Detail 1 for Network Detail Alarm : Dry Contact to Siren Light Installed in front of the animal room Fire Mode ( By Others) Animal Vivarium Control Applications he DM-A1 Universal Monitor can be configured to control the critical Environment in Animal Vivarium. his monitor can be flush mount to the wall on these rooms and provide the following parameter for monitoring purposes through 3 universal inputs on the monitor. hey are as following emperature of room Differential Pressure of Room Room Humidity he universal monitor also caters 3 digital outputs that can be used to control heaters and air tight dampers under decontamination conditions. hese air tight dampers can only be activated to close when a password is entered under decontamination conditions. In addition, all alarms conditions will activate a third DO to the siren or stroke light installed in front of these critical areas. Finally, there are two analogue outputs that are 4-20 ma and or 0-10Vdc to control air flow devices in the room to maintain proper air change and pressure regime. In addition, the monitor has a emergency button that allows the user to change the state of the room when a breakout occurs.

5 Singapore echnical / Sales Support Advance Laboratory System And Engineering Pte Ltd ( ALSE) 80 PlayFair Road Kapo Factory Building Block A, Unit Singapore el: Fax: Sale@advancelabsys.com.sg Local Distributor

6 Laboratory Application Fume Hood Monitor 136'-6" Scale 1 Volt / 1 volt / 1 Volt / 1250cfm Feedback from Airflow Devices Fume Hood Monitor Make Up 1 Volt / 1 volt / 1 Volt / 1250cfm Sash Sensor 0-10K Vdc 76'-0" Lighting Control Electrical Socket Enable Fan Motor he above application shows DM-A1 Universal Monitor being configured to control the critical environment in laboratory as a fume hood Monitor. his monitor can be flush mount to the fume hood cupboards and provide the following parameter for monitoring purposes through 3 universal inputs on the monitor. Sash Sensor / Face Velocity Sensor Flow Feedback From Airflow Devices Fan Status he monitor also caters 3 digital outputs that can be used to control fume hood lightings, fume hood exhaust fan and electrical socket.he 2 analogue output provides scale out to control the airflow devices, Variable Frequency Drives and also signal for exhaust air makeup devices. Additional Features he emergency button is present on the monitor that if depress, it will move the air flow devices to maximum flow. here is also a 50 dba alarm buzzer that will sound under alarm condition. he monitor also is fully configured for easy automatic setup. Display he Liquid Crystal Display will display the following Face Velocity / Flow/ Sash Sensor / Makeup Air Volume Laboratory and Fume Hood Number

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare Accutrol, LLC Product Sheet AVC6000 US Patents 6,991,177 & 7,543,759 Laboratories, Life Sciences, Healthcare AHR Expo AWARDS WINNER epi Innovative features for the AVC6000! Intuitive Graphical User Interface

More information

Acid Resistant AVC6000

Acid Resistant AVC6000 Accutrol, LLC Product Sheet Acid Resistant AVC6000 US Patents 6,991,177 & 7,543,759 Laboratories, Life Sciences, Healthcare Innovative features for the AVC6000! AHR Expo AWARDS WINNER Intuitive Graphical

More information

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare Accutrol, LLC Product Sheet AVC5000 US Patents 6,991,177 & 7,543,759 Laboratories, Life Sciences, Healthcare epi Exceptionally Low Pressure Drop Design System Pressure as low as 0.05" (12.5 Pa) Electronic

More information

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks Accutrol, LLC Product Sheet Cage Rack Valve H-AVC5000 US Patents 6,991,177 & 7,543,759 Specially Made for Vivarium Cage Racks Exceptionally Low Pressure Drop Design System Pressure as low as 0.05" (12.5

More information

Power Switching Devices

Power Switching Devices Watlow has manufactured solid state power controllers for over forty years. Watlow s is a microprocessor-based product that features application flexibility unmatched by any other silicon controlled rectifier

More information

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules Technical Specification Sheet Document No. 149-855 November 04, 2015 BACnet Lab and Pressurized Room Controllers with Off-board Air Modules NOTE: The 570-8xxPA BACnet laboratory controllers have new 67xx

More information

Laboratory Room Controller

Laboratory Room Controller Technical Specification Sheet Rev. 5, April, 2001 Laboratory Room Controller Description The APOGEE Automation System Laboratory Room Controller (LRC) provides Direct Control (DDC) for laboratory space

More information

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators Datasheet 53lb-in (6 Nm), Non-Spring Return Damper Actuators Overview The direct-coupled fail-safe/failin-place electronic actuators are designed for modulating, two position, and floating control of laboratory

More information

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation Instructions M9106AGx-2N0x Issue Date 08/31/01 M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation IMPORTANT: The M9106-AGx-2N0x Series actuator is intended to control

More information

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories HFB Airflow Management Damper Control damper for different airflow and duct pressure control applications Pressure-independent operation Galvanised steel design Circular duct connection equipped with integrated

More information

DPC300 FUME CUPBOARD CONTROLLER

DPC300 FUME CUPBOARD CONTROLLER home DPC300 FUME CUPBOARD CONTROLLER Ultra low face velcoity measurement Millisecond response time Excellent repeatability Total shut off and allround airtight Pressure independent from 5..750Pa Long term

More information

Description. functions including single duct pressure dependent or pressure independent systems.

Description. functions including single duct pressure dependent or pressure independent systems. Description The Meridian Basic control system converts a single zone HVAC unit into a variable air volume/variable air temperature multiple zone system. The microprocessor based Zone Manager calculates

More information

Non-Spring Return SMU... series

Non-Spring Return SMU... series Non-Spring Return SMU... series Product overview New Generation Non-spring return actuator Open/Close, 3-point AC 24 V 5/6 Hz, DC 24 V Auxiliary switch build-in SPD AC..24 V 5/6 Hz AC 23 V 5 Hz (Open/Close)

More information

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description TEK-AIR TECHNICAL PRODUCT DATA SHEET FVC2100/2200 FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER MODEL 2100: Constant face velocity, variable volume MODEL 2200: Constant face velocity, variable volume

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate Highly accurate measurements with calibration certificate Simple and quick

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS DESCRIPTION Honeywell Zephyr Digital Airflow Sensors: HAF Series-High Accuracy, provide a digital interface for reading airflow over the specified full scale flow span and temperature range. Their thermally

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare Accutrol, LLC Product Sheet AVT6000 US Patents 6,991,177 & 7,543,759 Laboratories, Life Sciences, Healthcare Innovative features for the AVT6000! AHR Expo AWARDS WINNER Intuitive Graphical User Interface

More information

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry. Precision Airflow Measurement An ONICON Brand CAMS Combustion Airflow Management System Proven solutions for a tough industry Precision Airflow Measurement An ONICON Brand CAMS TM Combustion Airflow Management System Product Description The Air Monitor

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves. Pressure Control Techniques. Dynamic Range

PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves. Pressure Control Techniques. Dynamic Range Valve Solutions w w w. m k s i n s t. c o m Downstream Pressure Controllers and Valves PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves Isolating and close-loop controlling each variable

More information

Description 1/8-7.5HP

Description 1/8-7.5HP Description 1/8-7.5HP J1000 In our pursuit to create drives optimized for variable speed needs in compact applications, the J1000 is the solution. This micro-drive is simple and reliable with Yaskawa quality.

More information

Pressure Transmitters

Pressure Transmitters Pressure Transmitters H Overview MODUFLEX Pressure and differential pressure transmitters Type series Ranges Medium Output Sensor Notes / application signal SN Pressure up Liquid and 0 10 V/ piezoresistive

More information

AT EVO SERIES BATTERY CHARGER

AT EVO SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY EVO AT Series Battery Charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation

More information

Laboratory Solutions. pricecriticalcontrols.com

Laboratory Solutions. pricecriticalcontrols.com Laboratory Solutions pricecriticalcontrols.com Laboratory Solutions Laboratory Space Controller Native BACnet MS/TP (BTL Listed) High speed room level network Control multiple supply and general exhaust

More information

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper Halton HFB Airflow Management Damper Control damper for different airflow and duct pressure control applications Pressure-independent operation Galvanised steel design Circular duct connection equipped

More information

COMPLETE and FULLY INTEGRATED AIR PRESSURE CONTROL & MONITORING SYSTEMS

COMPLETE and FULLY INTEGRATED AIR PRESSURE CONTROL & MONITORING SYSTEMS COMPLETE and FULLY INTEGRATED AIR PRESSURE CONTROL & MONITORING SYSTEMS BREATHE EASY Controllers Monitors Venturi Valves Sensors and More www.triatek.com Triatek began in 1985 by offering customers forward

More information

ATevo SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER PRODUCT OVERVIEW NEXT GENERATION NEW FEATURES: Interactive LCD display Intelligent self diagnostics NERC Compliant ATevo Battery Charger is the next generation SCR-based utility battery charger. The innovative

More information

PROGRAMMABLE DC POWER SUPPLY MODEL 62000P SERIES

PROGRAMMABLE DC POWER SUPPLY MODEL 62000P SERIES MODEL 62000P PROGRAMMABLE DC POWER SUPPLY MODEL 62000P SERIES : 0 ~ 600V ; : 0 ~ 120A ; : 600W, 1200W, 2400W, 5000W 0.95 / / : (5ms~99hours) 10 100 / / 8 bit TTL 5V APG (Analog Programmable Interface)

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet SF24G-S-S2- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

Acid Resistant AVT6000

Acid Resistant AVT6000 Accutrol, LLC Product Sheet Acid Resistant AVT6000 US Patents 6,991,177 & 7,543,759 Laboratories, Life Sciences, Healthcare Innovative features for the AVT6000! AHR Expo AWARDS WINNER Manufactured in the

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends Application Water-side control of heating and cooling systems for AHUs and water coils. Equal Percentage/

More information

HVAC Products. Introducing the SED2 Variable Frequency Drives

HVAC Products. Introducing the SED2 Variable Frequency Drives HVAC Products Introducing the SED2 Variable Frequency Drives Designed Specifically for HVAC Applications From a global leader in drives technology and innovation, now comes a drive specifically configured

More information

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH EN Dusty / Dusty Ex Operating Instructions Low-Cost Broken Bag Detection SWR engineering Messtechnik GmbH CONTENTS Page 1. Introduction.............................................................. 3 1.1

More information

Material Specification PVC valves shall meet ASTM D1784 cell classification 124 standards. CPVC valves shall meet ASTM D1784 cell classification 23447

Material Specification PVC valves shall meet ASTM D1784 cell classification 124 standards. CPVC valves shall meet ASTM D1784 cell classification 23447 Electrically Actuated Lug Butterfly Valve Type 147 General Size: 2 12 Outer Body: Glass-filled PP Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seals: EPDM, FPM, PTFE/FPM Stem: 316

More information

Temperature Controllers

Temperature Controllers Controllers SCR Power Controllers Introduction to Silicon Controlled Rectifier (SCR) Power Controllers Features and Benefits of SCRs High reliability Because the SCR power controller is a solid-state device,

More information

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data TC2000 TC2001 EUROTHERM ONTROLS Two phase thyristor power switches Product data TC2000 TC2001 Thyristor power switches Compact, two phase thyristor power switches for electrical heating applications from

More information

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM Honeywell Zephyr TM Analog Airflow Sensors HAF Series High Accuracy ±50 SCCM to ±750 SCCM Honeywell Zephyr TM Analog Airflow Sensors HAF Series - High Accuracy Honeywell Zephyr HAF Series sensors provide

More information

Temperature Controllers

Temperature Controllers SCR Power Controllers Introduction to Silicon Controlled Rectifier (SCR) Power Controllers Features and Benefits of SCRs High reliability Because the SCR power controller is a solid-state device, it provides

More information

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Low Pressure Sensor. Overview. Specifications. Installation and Operation Overview The Low Pressure Sensor with display measures building pressure, air velocities and volumes. The heart of the unit is a micro-machined silicon pressure sensor. The unit includes a static pressure

More information

See «Overview of types»

See «Overview of types» echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m Actuating

More information

Air Quality Solutions

Air Quality Solutions Air Quality Solutions Installation & Maintenance Manual Model: IAQ50X Air Measuring Station Indoor Air Quality Damper II-IAQ50X-818/Replaces II-IAQ50X-612 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE

More information

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS HIGH TEMPERATURE SENSORS AS STANDARD FOR PERMANENT INSTALLATION ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS The Ultraflo 2000 is a Transit Time ultrasonic

More information

Silver Series Thermal Dispersion Airflow Measurement Technology

Silver Series Thermal Dispersion Airflow Measurement Technology Thermal Dispersion Airflow Measurement Model STx104-U Unit Ventilator Airflow Measurement System Technical Data Silver Series Thermal Dispersion Airflow Measurement Technology APPLICATIONS Direct outdoor

More information

7 Services Control and monitoring

7 Services Control and monitoring Control and monitoring 7 Services We are the only manufacturer of laboratory equipment who offers you fume cupboards and variable fume cupboard control all from one supplier. Benefit from our know-how

More information

GS2 Series - Introduction

GS2 Series - Introduction GS2 Series - Introduction GS2 Series Drives Rating Hp.25.5 1 2 3 5 7.5 10 kw 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 Single-Phase 115 Volt Class Single/Three-Phase 230 Volt Class Three-Phase 230 Volt Class Three-Phase

More information

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor! PRESSURE SENSORS PRESSURE PDP3 Series 0-2 32 PDP3 Series 0-10, 0-25 34 PG Gauge Series 36 PW Wet-Wet Series (Cable Version) 38 PW Wet-Wet Series (Conduit Version) 40 PW Series Ordering Guidance 42 Selectable

More information

CMR CONTROLS AIR MANAGEMENT SYSTEMS PRESSURE VELOCITY SENSORS AND CONTROLS PRECISION COMPONENTS FOR VENTILATION AND PROCESS AIR CONTROL

CMR CONTROLS AIR MANAGEMENT SYSTEMS PRESSURE VELOCITY SENSORS AND CONTROLS PRECISION COMPONENTS FOR VENTILATION AND PROCESS AIR CONTROL Home AIR MANAGEMENT SYSTEMS PRESSURE VELOCITY SENSORS AND CONTROLS PRECISION COMPONENTS FOR VENTILATION AND PROCESS AIR CONTROL CMR TRANSDUCER manufacture accuracy AND REPEATABILITY IS most important The

More information

EVO AT SERIES BATTERY CHARGER

EVO AT SERIES BATTERY CHARGER EVO AT SERIES BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T PATENT PENDING hindlepowerinc.com 610-330-9000 Evo AT Series battery charger designed with YOU in mind. Evo AT Series battery charger

More information

Pressure Transmitter

Pressure Transmitter FCO318 Differential Pressure Transmitter Accuracy 0.25% of reading Ultra low pressure measurement Wide span adjustment 2-wire ma, 3-wire or 4-wire voltage output Two configurable relays and bi-colour LED

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 920 1920P01 Differential Pressure Sensors for neutral and mildly corrosive liquids and gases QBE63-DP Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and

More information

Application. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203)

Application. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203) TEK-AIR TECHNICAL PRODUCT DATA SHEET FVC2600 SASH SENSING VAV FUME HOOD SYSTEM MODEL 2600: Variable volume control based on sash position utilizes microprocessor based electronics and linear air control

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet SF24G-S- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building

More information

SLIM LINE FUME HOOD MONITOR

SLIM LINE FUME HOOD MONITOR SLIM LINE FUME HOOD MONITOR Phoenix Controls FHM420 Fume Hood Monitor is sized to fit any fume hood and includes icons for simple and universal operation. The FHM420 slim line monitor works in conjunction

More information

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device 2SGT Electronic Pressure Instrument Three Separate Functions in a Single Loop-Powered Device Switch Two Independent, Programmable SPST Solid State Relays Program switch open and close values in engineering

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION Electrical Energy Storage Tester EEST-511-S Semi-Automatic Charge-Discharge Battery Bench 1 channel 50 V / 100A (Ni-CD, Pb, Ni-Mh, Li-ion...) TECHNICAL DESCRIPTION To buy, sell, rent or trade-in this product

More information

RVS-DX Digital Reduced Voltage Motor Starter

RVS-DX Digital Reduced Voltage Motor Starter RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

Smart Products. Maxon Workshop Richard Reyes

Smart Products. Maxon Workshop Richard Reyes Smart Products Maxon Workshop Richard Reyes Critical gas flow control components Pressure Regulators Flow Control Valves Typical regulator MICRO-RATIO valves Basic control concept SMARTLINK technology

More information

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC The Z Series Zero-Fired SCR Power Controllers 60-1200 AMPS 120-600 VAC SCR Power controllers for resistance heating applications. ROBICON 1996 Rev. 7/96 Applications Robicon s Z series power controls are

More information

HUMIDITY / TEMPERATURE TRANSMITTER

HUMIDITY / TEMPERATURE TRANSMITTER HUMIDITY / TEMPERATURE TRANSMITTER SEM161, SEM16 CONFIGURATION USING USB PORT POWERED CONFIGURATOR HUMIDITY, TEMPERATURE, DEW POINT MEASUREMENT INTERCHANGEABLE DIGITAL SENSOR HIGH ACCURACY AND STABILITY

More information

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals IO Input/Output Modules IO-ABM4 Analogue Override Module Description IO-ABM4 Analogue Override Module Intended for applications which require independent manual override of analogue output channels from

More information

PRODUCTS: POWER SUPPLY

PRODUCTS: POWER SUPPLY PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER

More information

ComfortPoint Programmable Lon, VAV/Unitary Controllers

ComfortPoint Programmable Lon, VAV/Unitary Controllers ComfortPoint Programmable Lon, VAV/Unitary Controllers Controller Model Programmable Type Universal Inputs (UI) Table 1. Controller configurations. Digital Inputs (DI) PRODUCT DESCRIPTION INSTALLATION

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC DCV-LC Lab climate control External occupancy detector Lab climate control unit 24VAC + Communication Occupancy DCV-LC 24VAC + Communication AIN Adjustable function AOUT Adjustable function SMART DAMPERS

More information

Aurora Single Phase Emergency Lighting Inverters

Aurora Single Phase Emergency Lighting Inverters Aurora Single Phase Emergency Lighting Inverters True Sine Wave On-Line Single Phase Emergency Lighting Inverters AURORA Series Emergency Lighting AC Inverters are among the most reliable systems available

More information

SCR POWER REGULATORS & HEATING CONTROL PANELS SINGLE-PHASE TWO-PHASE THREE-PHASE 15 ~ 750+ AMPS.

SCR POWER REGULATORS & HEATING CONTROL PANELS SINGLE-PHASE TWO-PHASE THREE-PHASE 15 ~ 750+ AMPS. SCR POWER REGLATORS & SINGLE-PHASE TWO-PHASE THREE-PHASE 15 ~ 750+ AMPS Radix offers a full range of SCR Power Regulators as well as SCR Heater Control Panels. The Panels are manufactured in-house at the

More information

Healthcare Solutions Room Pressure Monitors and Controls

Healthcare Solutions Room Pressure Monitors and Controls Healthcare Solutions Room Pressure Monitors and Controls TOUCHSCREEN ROOM PRESSURE MONITOR The Touchscreen Room Pressure Monitor (PMT) provides precise room pressure monitoring for critical spaces such

More information

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER Evo Series battery charger designed with YOU in mind. Evo Series battery charger is a next generation SCR-based utility battery charger. This evolutionary

More information

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA V Series 120/120VAC Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA On-line, Single Phase, Double Conversion UPS The UniStar V features a field-proven

More information

Thyristor Power Regulators

Thyristor Power Regulators READY TO USE SCR-BASED HIGH PERFORMANCE & ENERGY EFFICIENT 1-PHASE, 2-PHASE AND 3-PHASE POWER REGULATORS SCR POWER REGULATORS FROM 15 AMPS TO 750 AMPS AND HIGHER Description RADIX brings you a full range

More information

Differential pressure sensor

Differential pressure sensor s 1 916 QBM3x20-.. QBM3x20-..D Differential pressure sensor for air and non-aggressive gases QBM3020-.. QBM3120-.. High degree of measuring accuracy Adjustable characteristic curve (pressure-linear or

More information

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature MEMS Mass Flow Sensor D6F-P A Compact, High-performance Flow Sensor with Dust Segregation Structure. Built in Dust Segregation System (DSS) with cyclone flow structure, diverts particulates from sensor

More information

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION... CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. INVERTER OPERATION... 11 6. TROUBLE SHOOTING GUIDE....... 16 7.

More information

AT SERIES EVO BATTERY CHARGER

AT SERIES EVO BATTERY CHARGER AT SERIES EVO BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T hindlepowerinc.com 610-330-9000 AT Series evo. A battery charger designed with YOU in mind. AT Series evo is HindlePower s next generation

More information

Non-Spring Return EconoDrive Floating Actuator

Non-Spring Return EconoDrive Floating Actuator MF4D-0x Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All

More information

2.6. Air Flow Control Valve Type PRD

2.6. Air Flow Control Valve Type PRD 2.6. Air Flow Control Valve Type PRD Page 1/10 Air Flow Control Valve, Type PRD Page 2/10 Air Flow Control Valve Type PRD Description and Design The PRD remains the air valve of choice for critical heating,

More information

SR1V. Industrial Low Cost String Pot

SR1V. Industrial Low Cost String Pot SR1V Industrial Low Cost String Pot User Scalable VDC Output Signal Linear Position Measurement up to 125 inches (3 meters) Designed for Outdoor / Wet environments In-Stock! SR1V is a rugged, low-cost,

More information

USERS MANUAL MCD REMOTE OPERATOR

USERS MANUAL MCD REMOTE OPERATOR USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3

More information

Electromagnetic flowmeter. Descriptions. Specifications

Electromagnetic flowmeter. Descriptions. Specifications Descriptions The EFM Series is the most economical flanged electromagnetic flowmeter on the market. It is used in 3 to 12 pipe in HVAC, municipal or industrial water, wastewater, pump stations and packaged

More information

Superstatic 440. Static Heat- and Cooling Meter. Application

Superstatic 440. Static Heat- and Cooling Meter. Application Superstatic 440 Static Heat- and Cooling Meter Application Design The Superstatic 440 is a static heat- and cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,

More information

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System

More information

TOP QUALITY SOLUTIONS FOR YOUR LABORATORY

TOP QUALITY SOLUTIONS FOR YOUR LABORATORY TOP QUALITY SOLUTIONS FOR YOUR LABORATORY Distributed By Polypropylene Ductless Fume Hood Easily dissembled back wall Tempered glass sliding front window Monitor displays fan s total operation time, for

More information

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes Sorensen XG 1700 Series 1700 W 1700 Watt, 1U Programmable DC Power Supplies 6 600 V Industry Leading Power Density Up to 1700 Watts in 1U Standard Digital Interfaces USB&RS232/485 LXI Ethernet and Isolated

More information

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS DESCRIPTION FT & FIT-1003 Series transducers include Models FT-1003, FT-1003-ZV, FIT-1003-D, FIT-1003-DZV, FIT-1003-M, and FIT-1003-MZV.

More information

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Series. On-line, Single-phase Parallel Redundant UPS System.   6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM Series 6 and 10 kva Rack Mount On-line, Single-phase Parallel Redundant UPS System n Power range and runtime scalability n Full-time Digital Signal Processor Control n LCD/LED mimic panel n Easy-to-set

More information

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For proportional modulation of dampers

More information

Three Phase UPS Systems Range: 10 to 500kVA

Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying

More information

The High Power Stack Horizon

The High Power Stack Horizon Voltage Supply 480-600-690V Current Rating from 150 to 2100A Designed to drive 1-2-3 Phase Loads Internal Fuse with Micro for Fuse Failure Stall Fan Protection for 1100 to 2100A Control Board with Plug

More information

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges and outputs 0 to 5/10 V or 4 to 20 ma. NEMA 4X / IP65 rated enclosure. For monitoring the differential pressure

More information

RoHS Directive-Compliant Motorized Linear Slides EZS Series for Clean Room Use. Features

RoHS Directive-Compliant Motorized Linear Slides EZS Series for Clean Room Use. Features Motorized Actuators RoHS Directive-Compliant Series for Clean Room Use The Series for Clean Room Use is a product designed with the same level of function and performance as the Series but is ideal for

More information

Low Profile DC Power Supply with Zero Voltage Soft Switching

Low Profile DC Power Supply with Zero Voltage Soft Switching Sorensen XFR Series Low Profile DC Power Supply with Zero Voltage Soft Switching Analog programming Zero voltage soft switching Constant voltage or constant current operation with automatic crossover and

More information

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1. LMCB4-SR (-T) Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMCB4-SR LMCB4-SR-T HALOMO Brushless

More information

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits DIN-A-MITE C TOTAL CUSTOMER SATISFACTION 3 Year Warranty SCR Power Controller Delivers Up To 80 Amperes in a Compact Package The DIN-A-MITE C silicon controlled rectifier (SCR) power controller provides

More information

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible

More information

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM Series 6 and 10 kva Tower On-line, Single-phase Parallel Redundant UPS System n Power range and runtime scalability n Full-time Digital Signal Processor Control n LCD/LED mimic panel n Easy-to-set user

More information

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS Powered by MTU G2300QX G2300X ELECTRICAL PRIME STAND BY Output Rating kva 2200 2360 kw 1760 1888 Frequency Hz 50 Rated Speed RPM 1500 Standard Voltage v 400/230

More information

Diesel generator set QSK23 series engine

Diesel generator set QSK23 series engine Specification sheet Diesel generator set QSK23 series engine 545 kw - 725 kw 60 Hz Data Center Continuous Description Cummins commercial generator sets are fully integrated power generation systems providing

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information