1 echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m Actuating force N Nominal voltage AC/DC V Control: modulating DC... V or variable Position feedback DC... V or variable Lenght of stroke, or 3 mm Communication via BELIMO -Bus Conversion of sensor signals Overview of types ype Stroke (adjustable in steps of mm) Operating range Weight SHA- p to max. mm DC... V... mm. kg SHA- p to max. mm DC... V... mm.7 kg SHA-3 p to max. 3 mm DC... V... 3 mm. kg echnical data Electrical data Nominal voltage AC V, /6 Hz / DC V Nominal voltage range AC V / DC V Power consumption In operation 3. nominal force At rest.3 W For wire sizing 6 VA Connection Cable m, x.7 mm Functional data Factory settings Variable Settings Actuating force Min. nominal voltage %, %, 7% reduced... Control Control signal DC... V, input impedance kω Open-close, 3-point (AC only), modulating (DC... 3 V)... Operating range DC... V Start point DC V (See also «Overview of types») End point DC V... Position feedback (Measuring voltage ) DC... V, max., ma Start point DC V End point DC.... V... Position accuracy ±% Stroke See «Overview of types» Direction of stroke at = V At switch position resp. Electronically reversible... Manual override Gearing latch disengaged with push-button, can be locked Stroke adjustment Max., or 3 mm, adjustable in steps of mm, can be limited at both ends with mechanical adjustable end stops Running time s / mm... 6 s / mm... Automatic adjustment of running time, operating range and measuring signal to match the mechanical stroke adjustment Override control Manual triggering of this adaption by pressing the button «Adaption» or with the PC-ool MAX (maximum position) MIN (minimum position) ZS (intermediate position, AC only) = % = % = % Automatic adaption whenever the supply voltage is switched on, or manual triggering... MAX MIN ZS Sound power level < db (A) With a running time of Safety Protection class Degree of protection EMC III Safety extra-low voltage / L Class Supply IP in any mounting position NEMA, L Enclosure ype CE according to /8/EC = (MIN 3%)... % = %... (MAX 3%) = MIN... MAX... s = db (A) 6 s = 3 db (A). 3-SHA-.. en v. 8.8 Subject to changes / 7
2 SHA-.. Multifunctional linear actuators, AC/DC V, N, echnical data (Continue) Safety Certification clus according to L 673-A and L and CAN/CSA E673-: Certified to IEC/EN 673- and IEC/EN Mode of operation yp Rated impulse voltage.8 kv Control pollution degree 3 Ambient temperature range 3... C Non-operating temperature... 8 C Ambient humidity range 9% r.h., non-condensating Maintenance Maintenance-free Dimensions / Weight Dimensions See «Dimensions» on page 6 Weight See «Overview of types» on page Safety notes! he actuator is not allowed to be used outside the specified field of application, especially not in aircraft or any other form of air transport. Assembly must be carried out by trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. he rotary supports and coupling pieces available as accessories must always be used if lateral forces are likely. In addition, the actuator must not be tightly bolted to the application. It must remain movable via the rotary support (refer to «Assembly notes»). If the linear actuator is exposed to severely contaminated atmosphere, appropriate precautions must be taken on the system side. Excessive deposits of dust, soot etc. can prevent the gear rack from being extended and retracted correctly. If not installed horizontally, the gear disengagement pushbutton may only be actuated when there is no pressure on the gear rod o calculate the actuating force required for air dampers and slide valves, the specifications supplied by the damper manufacturers concerning the surface, cross section, design, installation site and the air flow conditions must be observed. If a rotary support and/or coupling piece is used, losses in the actuation force are to be expected. he device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. Product features Mode of operation Converter for sensors Parameterisable actuators Simple direct mounting Conventional operation: he actuator is controlled with a standard modulating signal of DC... V and travels to the position defined by the control signal. Measuring voltage serves for the electrical display of the damper position... % and as slave control signal for other actuators. Operation on the -Bus: he actuator receives its digital positioning signal from the higher level controller via the -Bus and travels to the position defined. Connection serves as communication interface and does not supply an analogue measuring voltage. Connection option for a sensor (passive or active sensor or switching contact). he actuator serves as an analogue/digital converter for the transmission of the sensor signal via -Bus to the higher level system. he factory settings cover the most common applications. Input and output signals and other parameters can be altered with the MF-H parameterising device or the BELIMO Service ool, MF-P. he actuator can be directly connected with the application using the enclosed screws. he head of the gear rod is connected to the moving part of the ventilation application individually on the mounting side or with the Z-KS coupling piece provided. / 7 3-SHA-.. en v. 8.8 Subject to changes
3 SHA-.. Product features Manual override Stroke adjustment High functional reliability Home position Multifunctional linear actuators, AC/DC V, N, (Continue) Manual operation is possible with the pushbutton (the gearing latch remains disengaged as long as the pushbutton is pressed or detented). he stroke of the gear rack can be adjusted on both sides in increments of mm by means of mechanical end stops. he actuator is overload-proof, requires no limit switches and automatically stops when the end stop is reached. When the supply voltage is switched on for the first time, i.e. at commissioning or after pressing the «gear disengagement» switch, the actuator travels to the home position. Pos. Direction of stroke Home position = extended = retracted he actuator then moves into the position defined by the control signal. Accessories Description Data sheet Electrical accessories Parameterising device MF-H - MF-H PC-ool MF-P - MF-P Position sensor SGA, SGF and SGE - SG.. Digital position indication ZAD - ZAD Mechanical accessories Rotary support to compensate lateral forces Z-DS - Z-SH..A.. Coupling piece Z-KS - Z-SH..A.. Mechanical limiter set Z-AS - Z-SH..A.. Elektrische Installation Notes Connect via safety isolating transformer.! Other actuators can be connected in parallel. Please note the performance data! Anschlussschemas Konventioneller Betrieb Betrieb am -Bus Control signal Measuring voltage Sensor Cable colors: = black = red 3 = white = orange. Assembly notes Application without lateral forces Application with lateral forces Caution If a rotary support and/or coupling piece is used, losses in the actuation force are to be expected.! he linear actuator is screwed directly to the housing at three points. Afterwards, the head of the gear rod is fastened to the moving part of the ventilation application (e.g. damper or slide valve). he coupling piece with the internal thread (Z-KS) is connected to the head of the gear rod. he rotary support (Z-DS) is screwed to the ventilation application. Afterwards, the linear actuator is screwed to the previously mounted rotary support with the enclosed screw. Afterwards, the coupling piece, which is mounted to the head of the gear rod, is attached to the moving part of the ventilation application (e.g. damper or slide valve). he transverse forces can be compensated for to a certain limit with the rotary support and/or coupling piece. he maximum permissible swivel angle of the rotary support and coupling piece is, laterally and upwards. 3-SHA-.. en v. 8.8 Subject to changes 3 / 7
4 SHA-.. Multifunctional linear actuators, AC/DC V, N, Functions when operated on -Bus Connection on the -Bus Further actuators and sensors (max. 8) Supply and communication in one and the same 3-wire cable no shielding or twisting necessary no terminating resistors required Power topology here are no restrictions for the network topology (star, ring, tree or hybrid forms are permitted). Connection of active sensors Connection of external switching contact p Further actuators and sensors (max. 8) Further actuators and sensors (max. 8) Supply AC/DC A Output signal DC... V (max. DC... 3 V) Resolution 3 mv Switching current 6 V Start point of the operating range must be parameterised on the actuator as.6 V Connection of passive sensors Further actuators and sensors (max. 8) Sensor emperature range emperature range Resolution Ni C Ω Ω P 3... C Ω Ω NC... 6 C (depending on type) Ω... 6 kω Ω / 7 3-SHA-.. en v. 8.8 Subject to changes
5 SHA-.. Multifunctional linear actuators, AC/DC V, N, Functions with basic values (only in conventional mode) Override control with AC V with relay contacts a b c e.g. N 7 (DC... V) Functions a b c % Override control with AC V with rotary control switch 3 (DC... V) e.g. N 7 Pos % Functions ZS % (intermediate position) ZS % (intermediate position) % 3 % Control mode in according with Control mode in according with Remote control... % Minimum limit Z SGA SGF SGE Positioner Z SGA SGF SGE Positioner [V] (DC... V) min [%] Master/Slave control (position-dependent) Control with... ma via external resistance DC... V Ω () ()... ma DC... V o the following actuator DC... V Master actuator Slave actuator he Ω resistor converts the... ma current signal into a voltage signal DC... V Position indication Functional check ZAD Adapting the direction of rotation Procedure Apply V to connection and Disconnect connection 3: For direction of stroke : Actuator travels in the direction of For direction of stroke : Actuator travels in the direction of Short circuit connections and 3: Actuator runs in the opposite direction 3-SHA-.. en v. 8.8 Subject to changes / 7
6 SHA-.. Multifunctional linear actuators, AC/DC V, N, Functions for actuators with specific parameters Override control and limiting with AC V with relay contacts a b c d e (DC... V) Functions a b c d e CLOSE ) Override control and limiting with AC V with rotary control switch (DC... V) CLOSE ) MIN ZS MAX OPEN e.g. N 7 MIN ZS (intermediate position) MAX OPEN Control mode in acc. with ) Caution! his function is only guaranteed if the start point of the operating range is defined as min..6 V. 3-point control Open-close control a b Direction of stroke switch a b stop stop Dimensions [mm] Dimensional drawings e.g. N 7 ype Max. Stroke A B SHA SHA SHA B A 6 / 7 3-SHA-.. en v. 8.8 Subject to changes
7 SHA-.. Multifunctional linear actuators, AC/DC V, N, Operating controls and indicators 3 Direction of stroke switch Switching over: Direction of stroke changes Push-button and green LED display Off: No voltage supply or fault On: In operation Press button: Switches on stroke adaption, followed by standard operation 3 Push-button and yellow LED display Off: Standard operation without bus On: Adaptation or synchronising process active Flashing: Addressing request sent to maste Press button: No function Flickering communication active Gear disengagement switch Press button: Gear disengaged, motor stops, manual override possible Release button: Gear engaged, synchronisation starts, followed by standard operation Service plug For connecting parameterising and service tools Check voltage supply connection a) Off and 3 On Check the supply connections. Possibly and are swapped over. b) Blinking and 3 Blinking 3-SHA-.. en v. 8.8 Subject to changes 7 / 7
8 SHA-MF.. / SHA A A 3 Ø max. 8mm 3x 3x mm mm mm B 3 Z-KS M8 Z-KS mm mm ± M8 Z-KS mm Z-DS Z-DS. Z-DS. M-SHA-MF../SHA-.. v. 8.7 /
9 SHA-MF.. / SHA-.. AC V DC V DC V DC V DC V SHA-MF.. SHA-.. / M-SHA-MF../SHA-.. v
See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool
echnical data sheet LHA-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control
More informationElectrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V
echnical data sheet SH24A-SR.. Modulating linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m 2 Actuating
More informationElectrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing
echnical data sheet LH4A.. Linear actuators for operating air control dampers and slide valves in ventilation and air-conditioning systems For air control dampers up to approx. m Actuating force 5 ominal
More informationPower consumption In operation At rest For wire sizing
echnical data sheet LHK24A-SZ Modulating SuperCap linear actuator with emergency setting function and extended functionalities for adjusting air dampers and sliders in ventilation and air-conditioning
More informationPower consumption In operation At rest For wire sizing
echnical data sheet SHA.. inear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. m Actuating force 45 ominal voltage
More informationOverview of types. Technical data. Safety notes
echnical data sheet LH4A-S-P.. Linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air dampers up to approx.
More informationPower consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor
echnical data sheet SHK24A Linear actuator with capacitor technology for adjusting air dampers and sliders with emergency control function and extended functionalities in ventilation and air-conditioning
More informationTechnical data. Safety notes
echnical data sheet SM4A-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque Nm Nominal
More informationPower consumption In operation At rest For wire sizing
echnical data sheet SF24G-S- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building
More informationTechnical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch
echnical data sheet Damper actuator NM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up
More informationTechnical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch
echnical data sheet Damper actuator LM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up
More informationPower consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch
echnical data sheet SF24G-S-S2- Modulating spring return actuator with emergency function in the IP66 protective protecti e housing for adjusting air dampers in industrial plants and in technical building
More informationElectrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz
GR24A-5 / -7 GR24A-5 Rotary actuator for rotary valves GR24A-7 Rotary actuator for rotary valves Nominal torque 40Nm Nominal voltage AC/DC 24V Control Open-close echnical data Electrical data Nominal voltage
More informationTechnical data. Safety notes
echnical data sheet SMA-S-P Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque m ominal voltage
More informationPower consumption In operation At rest For wire sizing
echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage AC/DC
More informationPower consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch
echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx 4 m 2 orque 20 m ominal voltage AC/DC
More informationPower consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3
SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage
More informationPower consumption In operation At rest For wire sizing. Non-operating temperature
echnical data sheet DRC4G--7 Rotary actuator for butterfly valves for outdoor applications orque 90 Nm (not constant) Nominal voltage AC/DC 4 V Control: Open-close IP66 Optimum protection against moisture
More informationPower consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor
Technical data sheet GK24G- SuperCap rotary actuator with emergency setting function and extended functionalities in the IP66 protective housing for adjusting air dampers in ventilation and air-conditioning
More informationPower consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive
Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V
More informationPower consumption In operation At rest For wire sizing
echnical data sheet FA actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage
More informationElectrical data Nominal voltage AC 230 V Nominal voltage frequency
echnical data sheet NRA Rotary actuator for ball valves Nominal torque Nm Nominal voltage AC V Control Open-close, -point echnical data Electrical data Nominal voltage AC V Nominal voltage frequency 5/6
More informationPower consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return
echnical data sheet FA-S2 actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage
More informationPower consumption In operation At rest For wire sizing
echnical data sheet SFG- Spring return actuator with emergency function in the IP66 I protective protecti e housing for adjusting air dampers in industrial plants and in technical building installations
More informationTechnical data sheet. Technical data. Safety notes
echnical data sheet NM24P Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..6 m 2 orque 8 Nm Nominal voltage
More informationPower consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...
echnical data sheet SM24P-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..2 m 2 orque 8 Nm Nominal
More informationPower consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point
Actuators Technical data sheet Continuous control of rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in ventilation and air conditioning
More informationElectrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature
echnical data sheet SR24P-R Robustline rotary actuator for butterfly valves and rotary valves in Retrofit applications orque 18 Nm Nominal voltage AC/DC 24 V Control: Open-close or 3-point Optimum protection
More informationMinimum 18 in-lb Torque
CM Series Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM CMB Series - At A Glance CMB24-3 (p. 311) CMB24-3-T (p. 311) CMB120-3 (p. 313) CMB24-SR-R
More informationOverview of types. Technical data
Technical data sheet 6..S+NVFT24-MFT-E Globe valves, 2-way, with flange PN 16, actuator with emergency control function for closed hot water systems up to 150 C in district heating applications approved
More informationNon-Spring Return SMU... series
Non-Spring Return SMU... series Product overview New Generation Non-spring return actuator Open/Close, 3-point AC 24 V 5/6 Hz, DC 24 V Auxiliary switch build-in SPD AC..24 V 5/6 Hz AC 23 V 5 Hz (Open/Close)
More informationElectrical data Nominal voltage AC V / DC V Nominal voltage frequency
Technical data sheet NFG-S2-L Spring-return actuator with emergency control function for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque 10 Nm Nominal
More informationMinimum 27 in-lb Torque
LU Series Actuator Minimum 27 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM LU Series - At A Glance LUB(X)24-3 (p. 351) LUX120-3 (p. 353) LUB(X)24-SR (p. 355) LUX120-SR (p.
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
Technical data sheet DRK24A-5 SuperCap rotary actuator with emergeny control function and extended functionalities for butterfly valves Nominal torque 9 Nominal voltage AC/DC 24 V Control Open-close Design
More informationIn operation At rest For wire sizing
NMQ24A Damper actuator for adjusting air control dampers in ventilation and air-conditioning systems for building services installations orque 8Nm Nominal voltage AC/DC 24V Control: Open-close (not made
More informationElectrical data Nominal voltage AC 24 V Nominal voltage frequency
Technical data sheet Globe valve actuator with emergency control function for 2-way and 3-way globe valves Actuating force N Nominal voltage AC 24 V Control 3-point Nominal stroke 2 mm Design life SuperCaps:
More informationGlobe Valves. Technical Databook Version 1.2. Belimo Asia Pacific
Globe Valves Technical Databook Version 1.2 Belimo Asia Pacific Contents Globe Valves Product Overview Max. Close-off Pressure - Globe Valve Series Globe Valve Actuators Product Overview 4 5 General Information
More informationTechnical data. Safety notes
echnical data sheet MP-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx 6 m orque 8 m ominal voltage
More informationLMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma
LMX0-SR Proportional Control, Non-Spring Return, Direct Coupled,00 to 0 VAC, for to 0 VDC and to 0 ma Torque min. 5 in-lb for control of damper surfaces up to sq ft. Application For proportional modulation
More informationMinimum 27 in-lb torque
LU Series Actuator Minimum 27 in-lb torque For damper areas up to 6.8 sq-ft* All Actuators have BDCM LU Series - At A Glance LUB(X)24-3 (p. 258) LUB(X)24-SR (p. 260) LUX24-MFT (p. 262) Basic Product Flexible
More informationActuators for heating, ventilation, air-conditioning 2. LM-4 -CD. Product Information Damper actuators. i
Actuators for heating, ventilation, air-conditioning. LM-4 -CD Product Information Damper actuators LM i689 he complete range of damper actuators for general use in HVAC systems ype LM NM SM AM GM LF AF
More informationPower consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point
Actuators Technical data sheet Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor
More informationGMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma
Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 360 in-lb for control of damper surfaces up to 90 sq ft. Application For proportional modulation of dampers
More informationVersatile and Powerful
LM Series Direct Coupled Actuator Versatile and Powerful Minimum 45 in-lb torque in a compact package. For damper areas up to 11 sq-ft* Actuators in bold have BDCM LM Series - At A Glance LMB(X)24-3(-S)(-T)
More informationPower consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point
Actuators Technical data sheet Rotary drive Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor Nominal Voltage Control Damper size Damper
More informationP2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends
P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends Application Water-side control of heating and cooling systems for AHUs and water coils. Equal Percentage/
More informationVersatile and Powerful
AM Series Direct Coupled Actuator Versatile and Powerful Minimum 180 in-lb torque in a compact package. For damper areas up to 45 sq-ft* All Actuators have BDCM AM Series - At A Glance AMB(X)24-3 (p. 148)
More informationLMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.
LMCB4-SR (-T) Proportional Control, Non-Spring Return, Direct Coupled, 4V, for to 0 VDC and 4 to 0 ma Torque min. 45 in-lb for control of damper surfaces up to sq ft. LMCB4-SR LMCB4-SR-T HALOMO Brushless
More informationPower consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point
Actuators Technical data sheet Continuous control of spring return actuator Description Spring-return actuator for adjusting and regulating dampers and valves in air conditioning and ventilation. Torque
More informationCurrent consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time
Technical data sheet Rotary actuator SY-4--T Rotary actuators for butterfly valves Torque 50 Nm Nominal voltage AC 4 V Control: Open-close or -point Auxiliary switch Technical data Electrical data Nominal
More informationNMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology
NMQB-MFT, NMQX-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Application For proportional modulation of dampers in HVAC systems. Actuator sizing should
More informationZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators
ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators The ZG-JSL jackshaft linkage is designed to easily attach to any part of a jackshaft and allow easy installation
More information2. A E LM Form-fit versions Linear adapter ZH-LM
Actuators for heating, ventilation, air-conditioning 2. A1-90122 - E LM Form-fit versions Linear adapter ZH-LM OEM at001707 at00205 Linear adapter ZH-LM: For LM2... damper actuators with universal spindle
More informationNMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology
NMB (X) -MFT Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Torque min. 90 in-lb for control of damper surfaces up to sq ft. Technical Data NMB(X)-MFT Power Supply
More informationActuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.
Actuators for heating, ventilation, air conditioning 2. F-2 -CD Product Information Damper actuators with spring return F i6772 Contents Selection table orque 4 Nm F24 F24-S F23 F23-S F24-3 F24-S Nominal
More informationButterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific
Butterfly Valves Technical Databook Version 7.2 Belimo Asia Pacific BFV and Actuators Product Range Overview and Applications BU6..Series Motorised Butterfly Valves page 4 BU6..Series Butterfly Valves
More informationNominal voltage Nominal voltage range Power consumption Wire / tranformer sizing. Connection: Motor LMU24(-S/-F) Cable 1m, 3x0.
LMU24(S/F/) For operation of air control dampers in HVAC system orque: 5Nm Nominal voltage: AC/DC 24V Control: Open/Close or 3point echnical data Electrical data Functional data Working conditions Nominal
More informationGMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC
On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 00 to 40 VAC Torque min. 60 in-lb for control of damper surfaces up to 90 sq ft. Application For on/off and floating point control of dampers
More informationNFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V
NFB4, NFB4-S, NFX4, NFX4-S On/Off, Spring Return, 4 V Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB4... NFX4...
More informationLF Series Spring Return Direct Coupled Actuator
LF Series Spring Return Direct Coupled Actuator Minimum in-lb torque LF actuator For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including:
More informationkvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
Technical data sheet EV..R+BAC Characterised control valve (CCV) with sensor-operated flow rate or power control, power and energy-monitoring Nominal voltage AC/DC 4 V Control modulating For closed cold
More informationLMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
LMB- (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 5 in-lb for control of damper surfaces up to sq ft. Technical Data LMB- on/off-floating Power Supply VAC ±
More informationPower consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω
Actuators Technical data sheet Rotary actuator for control of volumetric flow without spring return Description Actuator for Volumetric flow and pressure control. Torque Motor Nominal Voltage Control Pressure
More informationMinimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.
TF Series Spring Return Direct Coupled Actuator Minimum 18 in-lb Torque For damper areas up to 4.5 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom
More informationMount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)
EFB and EFX Series Spring Return Direct Coupled Actuator Minimum 70 in-lb Torque For damper areas up to 66 sq-ft* (For lower torque, see AFB, AF, NFB, LF, or TF series) Applications New standard clamp
More information[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
Technical data sheet EV..R+KBAC Characterised control valve (CCV) with sensor-operated flow rate or power control, power and energymonitoring function, 2-way, internal thread (Energy Valve), with emergency
More informationCharacterised Control Valves with Actuators
Characterised Control Valves with Actuators echnical Databook Version 6.2 Belimo Asia Pacific Product Overview and able of Contents able of Contents 2 Control Valves and Actuators Product Overview 3 Characterised
More informationAMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
AMB-(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 80 in-lb for control of damper surfaces up to 5 sq ft. Application For on/off and floating point control of dampers
More informationCurrent consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time
Technical data sheet Rotary actuator SY-4--T Rotary actuators for butterfly valves Torque 5 Nm Nominal voltage C 4 V Control: Open-close or -point uxiliary switch Technical data Electrical data Nominal
More informationSpring-Return Damper Actuator NF24(-S)
Spring-eturn Damper Actuator NF24(-S) For operation of air control dampers that perform safety function Torque: 7Nm Nominal voltage: AC/ Control: Open/Close Integrated auxiliary switch NF24-S Technical
More informationLF Series At A Glance
LF Series Spring Return Direct Coupled Actuator Minimum 35 in-lb Torque For damper areas up to 8 sq-ft* Applications Cost effective quality and performance for a range of applications including: Classroom
More informationAMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
AMB4-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 80 in-lb for control of damper surfaces up to 45 sq ft. Application For on/off and floating point control of
More informationOutput signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W
Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges and outputs 0 to 5/10 V or 4 to 20 ma. NEMA 4X / IP65 rated enclosure. For monitoring the differential pressure
More informationFSAF24(-S) US, FSAF120(-S) US
FSAF4(-S) US, FSAF10(-S) US On/Off, Spring Return, Meets 50 F [11 C] for Half Hour, 75 Seconds Torque min. 133 in-lb, for control of air dampers Technical Data FSAF4(-S) US, FSAF10(-S) US Power supply
More information[ ] Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet EP..R+KMP Communicative characterised control valve with sensor-operated flow control and emergency control function, ominal voltage CC 2 V Control Modulating or closed cold and warm
More informationMinimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator
NFB and NFX Series Spring Return Direct Coupled Actuator Minimum 90 in-lb Torque For damper areas up to sq-ft* Applications 1 3/4 1/ New standard clamp fits standard 1/ shafts to 1.05 jackshafts. Mount
More informationBelimo is the Worldwide Leader in Fire and Smoke Actuation
FS Series Fire and Smoke Direct Coupled Actuators Belimo is the Worldwide Leader in Fire and Smoke Actuation Gateway Base II, Hong Kong Belimo first produced actuators for the European fire and smoke damper
More informationPN [ ] D7150NL/BAC D7200WL/BAC D7250WL/BAC D7300WL/BAC [ ]
Technical data sheet D7../C utterfly valve with actuator, Flange, P 16 Torque motor 160 m ominal voltage C 24...240 V / DC 24...125 V Control Open-close, modulating, communicative for mixing and diverting
More informationMount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)
AF Series Spring Return Direct Coupled Actuator Minimum 133 in-lb torque For damper areas up to 35 sq-ft* (For lower torque, see NF, LF, or TF series) Applications Remove for 3/4 to 1.05 shafts ZG106 or
More informationCharacterised Control Valves with Actuators
Characterised Control Valves with Actuators Technical Databook Version 8.6 Belimo Asia Pacific Contents Control Valves and Actuators Product Overview 4 Characterised Control Valve 6 Sizing of Ball Valves
More informationGM Series Direct Coupled Actuator
GM Series Direct Coupled Actuator Minimum 3 in-lb torque** For damper areas up to 8 sq-ft* Applications Linkage is part of inlet vane assembly supplied by manufacturer. Actuator is mounted to vortex frame.
More informationAF Series Spring Return Direct Coupled Actuator
AF Series Spring Return Direct Coupled Actuator Minimum in-lb torque For damper areas up to sq-ft* (For lower torque, see NF or LF series) Applications Direct Coupling - The Belimo Concept Remove for /
More informationAir damper actuators
4 654 OPEN AIR Air damper actuators Linear version, three-position control, AC 24 V or 230 V GDB..3..2 GLB..3..2 Electric motor-driven linear actuators for three-position control, nominal linear force
More informationVAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications
VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications 1 2 3 4 5 6 7 8 Technical data sheet 227CS-024-08-V Actuator without spring return for flow- or pressure
More informationSAX Electronic Valve Actuator
SAX Electronic Valve Actuator Non-spring Return, 24 Vac, Proportional Control Technical Instructions Document No. 155-506 Description The SAX Non-spring Return (NSR), Electronic Valve Actuator requires
More informationDirect Coupled Damper Actuator Model MY9050A1001
AB-4 Specifications/Instructions Direct Coupled Damper Actuator Model MY9050A00 General Model MY9050A00 direct coupled damper actuator is a motorized actuator to open/close a damper. Model MY9050A00 contains
More informationSM24A. Technical data. Dimensions [mm]
SM24A Damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services orque 2Nm Nominal voltage AC/DC 24V Electrical data Nominal voltage AC 24V, 5/6Hz / DC
More informationButterfly Valves. Technical Databook. Belimo Asia Pacific
Butterfly Valves Technical Databook Version 6 Belimo Asia Pacific Index BFV and Actuators Product Range Overview and Applications BU6..Series Motorised Butterfly Valves BU6..Series Butterfly Valves General
More informationMF /MS Series
MF41-6153/MS41-6153 Series 24 Vac, Three-position/Modulating Non-spring Return Rotary Electronic Damper SmartX Actuators General Instructions Description The direct-coupled, 24 Vac, non-spring return electronic
More informationPushing 1) force. Motor Spring [N] [kg]
51.368/1 AVF 124S, 125S: Valve drive SUT with spring return For controllers with continuous output (0...10V) or switched output (2-point or 3-point control). To operate through valves or three-way valves
More informationProduct Cross Reference
AF120 US, AF120-S US AF230 US, AF230-S US AFBUP, AFBUP-S, AFXUP, AFXUP-S Torque 133 in-lb [15 Nm] minimum 180 in-lb. [20 Nm] minimum OPERATION Running Time Noise Level < 75 seconds
More informationGDB..3..1A GLB..3..1A
4 624 OpenAir Air damper actuators Rotary version, three-position control, AC 24 V or AC 230 V GDB31A GLB31A Electric motor-driven actuators for three-position control, 5 / 10 Nm nominal torque, AC 24
More informationAir damper actuators
4 626 OpenAir TM Air damper actuators Rotary version, three-position control, AC 24 V or AC 230 V GBB13...1 GBB33...1 Electromotive rotary actuators for three-position control, nominal torque 20 m, operating
More informationDuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating
General Instructions DuraDrive MF4-653/MS4-653 Series Non-spring Return Rotary Electronic Damper Actuators 4 Vac Three-position/Modulating Description The DuraDrive direct-coupled, 4 Vac, non-spring return
More informationAF Series Spring Return Direct Coupled Actuator
AF Series Spring eturn Direct Coupled Actuator Minimum in-lb torque For damper areas up to 5 sq-ft* (For lower torque, see NF, LF, or TF series) Applications emove for / to.5 shafts ZG6 or ZG 7 bracket
More informationWe reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Features and functions Power supply Standard
More informationSBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions
Operating Instructions BKS24-9A Operating Instructions BKS24-9A Table of contents Operating Instructions 1 Operating controls and indicators 2 2 Preparations for faultless commissioning and operating 3
More informationOutput signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V
Duct Sensor Humidity / Temperature Duct mounted combined humidity (VDC) and temperature sensor. 2% accurate rh, available with dual active outputs or passive for temperature. Nema 4X / IP65 rated enclosure.
More informationNon-Spring Return EconoDrive Floating Actuator
MF4D-0x Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All
More informationElectromotoric actuators
4 573 SQS35.50, SQS35.53, SQS65.5 with spring return function, without manual adjuster ACVATIX Electromotoric actuators for valves with 5.5 mm stroke SQS35.00, SQS35.03, SQS65, SQS65.2, SQS85.00, SQS85.03
More information