1 ISO 9001: 2008 EN ISO 14001: 2004 SECURITY SYSTEMS Bollards INSTALLATION INSTRUCTIONS PNEUMATIC RISING BOLLARDS

2 INDEX Page 1. GENERAL INFORMATION SYSTEM COMPONENTS Construction Control Cabinet Electrical and Electronical Components Pneumatic Components OPERATION INSTRUCTIONS MAINTENANCE PRACTICAL TROUBLESHOOTING PROCEDURES CE DECLERATION ISO 14OO1 : 2004 CERTIFICATE ISO 9001 : 2008 CERTIFICATE

3 1. GENERAL INFORMATION Pneumatic rising bollards are designed especially for high security vehicle entrances and for locations that has to be closed for motorized traffic on specific times (like private roads, controlled parking areas, industrial areas, shopping lanes, marketplaces etc). Whenever a vehicle collision occurs; bollards will destroy the front suspension system, steering linkage and other parts of the drive system so the vehicle will be inactivated. They can be installed as a single unit as well as in groups. Bollards are driven pneumatically and the pneumatic drive unit is placed in an installation cabinet close to the bollards. In case of power failure bollards can be lowered a few more times by the help of the pressurized air in the tank. Typical raise/lower time is 3-5 seconds. Standard unit has raised height of 60 cm but for special requirements up to 90 cm lifted height can be manufactured. With the help of plc/microprocessor controlled electronics, raise/lower function can be achieved by every kind of card readers, biometric readers like fingerprint or hand shape, radio control, on/off switch or keyswitch etc. Besides, safety accessories like loop dedectors, photocells, flashing lights or red/green lights can be integrated to the control electronics very easily. Picture 1. General View of Bollards 1- Pneumatic Bollard 2- Control Cabinet 3- Security Photocell(optional) 4- Red/Green Lights(optional) Environmental Conditions and Power Requirement Between -20 C and +75 C, % 95 non-condensing humidity, 380 V 50~60 Hz Optional Accesories 1. Flashing or red/green lights 2. Radio control receiver, transmitter and antenna 3. Safety photocell, stand and casing 4. Inductive loop detector 5. Drainage Pump (or 220 V, 50~60 Hz, optional ) 6. Card Reader System 7. Uninterrupted Power Supply(UPS) to drive control electronics only PRB Series Pneumatic Rising Bollards TYPE DESCRIPTION PRB cm height when raised,single pneumatic unit, single bollard PRB cm height when raised, single pneumatic unit, two bollards PRB cm height when raised, single pneumatic unit, three bollards PRB cm height when raised, single pneumatic unit, four bollards HRB cm height when raised, single pneumatic unit, five bollards 3

4 2. SYSTEM COMPONENTS 2.1 Construction Lifting section of the bollard is manufactured from hardened steel tube with a diameter of Ø270 mm and wall thickness of 10 mm. Roadway surface area is covered by a heavy duty plate. The bollard and foundation tube is mounted into a reinforced concrete foundation. This foundation has pipings for cables and hoses. Bollard is designed to withstand 20 tons of axle load when lowered. In case of power failure at lifted position, bollard can be lowered/raised a few more times with the help of the already pressurized air in the tank. Parts forming the drive unit, namely, piston, piston rod, reservoir, solenoid or manual valves, etc. are very precisely manufactured so that they can stand the most harsh environmental conditions. All the parts are hot dip galvanized (60µm) or epoxy coated in order to prevent rusting. In addition, the parts which stand above the ground level are electrostatically powder coated or pistol painted to traffic yellow and black. Drawing 1. Foundation Dimensions 4

5 Foundation tube is the construction that guides bollard during raise/lower action. The bottom flange of the pneumatic cylinder is mounted in the tube therefore the tube has also a part which pneumatic hoses pass through. The pneumatic connections can be reached through this rectangular channel by removing top plate. Bollard Dimensions Road Level Drawing 2. Bollard Dimensions and Operating Positions Concrete Foundation Dimensions (Approximate Values) A A B B PNEUMATIC HOSE CONDUIT PROXIMITY SWITCH DATA CABLE CONDUIT DRAINAGE CONDUIT SECTION A-A SECTION B-B Drawing 3. Concrete Foundation Dimension 5

6 2.2 Control Cabinet Material : 2 mm thick sheet metal (electrogalvanized, RAL 7035 electrostatically powder coated and furnaced) Optionally;1.5 mm thick AISI 304 Quality Stainless Steel Dimensions : 150 cm x 220 cm x 150 cm (Cabinet may be manufactured in different dimensions according to requirements) Picture 2. Control Cabinet Views 1- Cabinet Side Cover 2- Open/Close Handle and Lock with Key 3- Electronic s cabinet 4- Cabinet Front Cover 2.3 Electrical ve Electronics Components Control electronics utilized in pneumatic rising bollard is plc/microprocessor controlled. Raise/lower function can be achieved by every kind of card readers, biometric readers like fingerprint or hand shape, radio control, on/off switches or keyswitches etc. Besides, safety accessories like loop dedectors, photocells, flashing lights or red/green lights can be integrated to the control electronics very easily. As control of the bollard is always through an electronic control cabinet, it is possible to interface any control method as part of a complete site security system. Time delay lifting of the pneumatic rising bollard can be adjusted between 0-50 seconds. Power requirement of the pneumatic bollard is 380 V 50~60 Hz (or 220 V 50~60 Hz, optional). 6

7 1. Emergency Stop Button 2. Auto Lower Button 3. Auto Raise Button 4. Switching Power Supply 5. Termic Failure Light 6. Operation Warning Light 7. Phase Failure Light 8. Fuse Group 9. Motor Fuse 10. Contactor 11. Relay Group 12. PLC 13. Motor Fuse 14. Time Relay 15. Terminal 16. UPS Picture 3. Control Cabinet Electrical and Electronics Components Picture 4. Desktop Control unit 17. Emergency Stop Button 18. Auto Raise Button 19. Auto Lower Button 20. Local Enabled(light on) 21. Left-Control at cabinet Right-Control at Keyboard Optional Accesories Control Electronics Security Photocells Red/Green Traffic Lights RF Receiver RF Transmitter Inductive Loop Dedector 7

8 2.4 Pneumatic Drive Group Components 1- Motor 2- Radiator 3- Air Reservoir(tank) 4- Cylinder Block 5- Compressor Block Oil Fill İnlet 6- Oil Level Gauge 7-8-Solenoid Valves 9- Air Filter 10- Air Output Vane Manometer 12-Pressure Breaker 13- Humidity collector (from air) 14-Regulator 15-Oil Supply(for air) 16-Pneumatic hose distributor Picture 5. Pneumatic Components 8

9 Picture Water drain valve. 9

10 3. OPERATION INSTRUCTIONS 1. Open the control cabinet.this machine must operate in an airy and clean place. Picture 6. Opening Control Cabinet 2. Open the oil fill inlet (Picture 5,item 5) and fill cylinder block (Picture 5,item 4) untill the oil level gauge (Picture 5,item 6) indicates up line. Warning:Your compressor is full of oil to start working.therefore you do not need to add any.but we still recommend you to control the oil level. 3. Make all the electrical connections according to the drawings supplied, attached to this manual.(3 phase,neutral,ground,traffic lights,proximity switch,way solenoids(at the bollards) and keyborad) 4. Make the hose connections at the pneumatic Hose Connection (Picture 5,item 16) and the solenoid vanes at the bollards. 5. Open the air output vane (Picture 5,item 10). 6. Turn on the power switch of the Uninterrupted Power Supply (UPS) and turn on the fuse group (Picture 3,item 8). CHECK MOTOR DIRECTION.THERE IS A SIGN ON THE MOTOR WHICH SHOWS THE RIGHT MOTOR DIRECTION.CHECK IT WITH THE PROPELLER TURNING DIRECTION.THEY MUST BE THE SAME.OTHERWISE RADIATOR WILL NOT OPERATE AND COOL THE SYSTEM. 7. Compressor will start working and filling the high pressure tank.wait untill the pressure raises to 10 bars.it will stop automatically. 8. If main control switch on the keyborad (Picture 4, item 21 ) is on left position, then the control of the system is on the control cabinet.but if the switch is on the right position,then the control is on the keyboard. Keep the control on the keyboard, therefore keep the control switch on the keyboard (Picture 4,item 21) on right. 9. Make sure both of the emergency stop buttons (Picture 4, Item 17 and Picture 3,item 1) are not pressed. 10. Check oil level from the gauge (Picture 5, Item 6) on the cylinder block(picture 5, Item 4). It should be around up line (It is not necessary to check oil level if low-oil auto-block system is implemented). 11. To raise bollard; press auto up button (Picture 4, Item 18) once. 12. To lower bollard; press auto down button (Picture 4, Item 19) once. 10

11 13. Humidity collector has a reservoir (Picture 5, Item 13) underneath. It collects water to this reservoir. This reservuar has the vane at the bottom. This vane is used to drain the collected water. Therefore, user must follow the fullness of this reservoir and drain it when necessary.the frequency of this process depends on the humidty of the environment and working hours of the compressor. 14. Oil supply gives oil to air(picture 5, Item 15) which are going to the solenoid vanes. Put oil to its reservoir when necessary.the oil there is not an ordinary oil,it is called oil to condition air for pneumatic pistons. 15. Air filter must be cleaned once a week (Picture 5, Item 9). Please follow the directions above for both entrance and exit bollards. How to connect/disconnect pneumatic hose to the solenid valve? Please follow the steps explained below to achieve this: Valve has one air input in the middle. Pneumatic hose will be connected to valve from there, as in picture 1. Firstly open top lid. Picture 1 Push the hose which is coming from cabinet to the valve. This prosses doesn t need to tighten or loseen any mechanical elements. Only push the hose from the valve s air input,as picture 2. Picture 2 If pneumatic hose is wanted to be disconnected from valve by whichever reason; Valve s air input has type plastic mechanism a spring loaded ring mechanism while pulling the. Push pneu this hose as in picture 3. matic Picture 3 11

12 8. MAINTENANCE Pneumatic Rising Bollard is built entirely of steel components and all parts of body, drive unit, bollard etc are hot dip galvanized (60µm) or epoxy coated against corrosion. Bollard is also permanently installed in a reinforced concrete foundation. Therefore, if bollard is maintained properly, it will work many years trouble free and give realiable service. Oil Check Oil Used: Mobil 306 First oil change to be made after 100 working hours, next changes to be made after every 1000 working hours. Filters Check Filter must be cleaned by pressurized air once a week and must be changed once in every three months. Clack Check Clacks, which are on the heads,have to be loosened and cleaned after every 1000 working hours. During normal operation if compressor s pressure decreases or heads are overheated, then,clacks must be loosened and cleaned.if there are any damages at clacks,they must be replaced by a new one. Clack and leak control; Adjust compressor s pressure (It is already adjusted now). Close all the vanes. Start the compressor.it will stop automaticly when it reaches the desired pressure.wait several munites. Investigate the pressure gage. If the pressure does not decrease,then, there isn t any leak on the compressor. If pressure decreases,then, there is leak from compressor clacks, vanes or other connections. Investigate to reason. Reconstruct or buy new one,to be replaced for the damaged members. Oil Leakage Check System to be eye-controlled for oil leakage once in every 3 months. Pressure Check Manometer pressure values must be checked at every leakage control to see if there is any deviation from the values stated by the manufacturer. UPS Check UPS batteries to be checked in every two years. Maintenance Staff All system controls to be made by qualified technical staff only. Only original equipment manufacturered or recommended by the manufacturer to be used at repair and/or maintenance procedures. Drainage of water from compressor tank. Once in every seven days, open water drain valve (picture 5.1, item 17) and drain the water in the tank. Close the valve again after all the water is drained. 12

13 9. PRACTICAL TROUBLESHOOTING PROCEDURES If there is no movement observed after pressing auto raise/lower buttons; - Make sure emergency stop buttons (Picture 4, Item 17 and Picture 3, Item 1) are not pressed. - Make sure all fuses (Picture 3, Item 8) are in upwards position. - Make sure keyboard control switch is on the proper position. If there are unexpected behaviours in system, quickly stop the system by pressing emergency stop button (Picture 4, Item 17). In case of power failure, - Bollards will continue to work for a few more times as there is already pressurized air in the reservoir. Please follow the directions above for both entrance and exit bollards. If the system is not still running after all these controls please contact with the manufacturer. Diagram for Finding Failure for Compressor Failure Probable Reason What must be done? 1.If air supply decreases There is leakage at the first level suction clacks. Loosen the clacks, clean them or change with a new one. There is adherance at the discharge piston. Dismount the piston then clean and lubricate it. Dirty air is sucked. Clean the filter. 2.If intercooler pressure is too low There is leakage at the first level suction clacks. Dismount the clacks, clean them or change with new one. 3. If intercooler pressure is too high There is blockage eitherat the discharge piston or release Dismount the piston then clean and oil lubricte it. valve. There is leakage at the second grade absorb clacks. Loosen the clacks, clean them or change with new one. 4. If there is excessive heat at the compressor. Intercooler and cooling fin is dirty. Clean the compressor by pressurized air. Calck is to be damaged. Oil lubriction is not enough. Renew to old one, fill oil until line is on the dip rode. 5. If oil consumption is too high Oil level is too high. Empty oil untill designated oil level. Piston ring had been abrasioned Renew the old elements. and/or piston and cylinder had been aged. 6. If there is noise and vibration at the compressor. Piston is hitting cylinder s head. Put a new gasket between the cylinder and cylinder s head. Piston is hitting the calck. Inspect to clack s gasket. Balance wheel or air blower had been loosen. Tighten bolts and nuts. 7. If there is evacuation at the first level safety release valve. There is leakage at the second level suction clacks. Safety release valve had been loosened. Dismount the clacks, clean them or change with a new one. Dismount the valve. Clean the valve and then assemble it to the initial place. 13

14 DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98 / 37 EEC, ATTACHMENT II, PART B) Manufacturer: OPTİMA MÜHENDİSLİK LİMİTED ŞİRKETİ KERESTECİLER SANAYİ SİTESİ 3. CADDE NO:8 SARAY KAZAN / ANKARA/ TÜRKİYE Declares that the products, HRR SERIES HYDRAULIC RISING ROADBLOCKERS HTK SERIES HYDRAULIC TYRE KILLERS HRB SERIES HYDRAULIC RISING BOLLARDS HDAB SERIES HYDRAULIC DROP ARM BARRIERS ELECTROMECHANICAL SLIDING GATE OPERATORS PRB SERIES PNEUMATIC RISING BOLLARDS PRR SERIES PNEUMATIC RISING ROAD BLOCKERS are constructed to be incorporated in a machine or to be assembled with other machinery to construct a machine considered modified by the directive 98 / 37 EEC are in confirmity with the regulations of the following EEC directives. Directive 98 / 37 EEC directive for machines Directive 73 / 23 EEC and directive 93 / 68 EEC low voltage Directive 89 / 336 EEC and directive 92 / 31 EEC and directive 93 / 68 EEC electromagnetic compatibility. And also are in confirmity with the following national standards. - TS EN / January 1996 Standard - TS EN / January 1996 Standard - TS EN 563 / April 1997 Standard - TS EN 418 / November 1995 Standard - TS EN / December 1995 Standard - TS EN / April 1995 Standard - TS EN / February 1998 Standard - TS EN / April 1997 Standard 4 April 2001 Ankara TURKEY İsmail Tamer ÜLGEN President Mechanical Engineer, B. Sc. 14

15

16

INDEX. 2.1 Construction and Foundation Control Cabinet Electrical and Electronics Components Hydraulic Units...

INDEX. 2.1 Construction and Foundation Control Cabinet Electrical and Electronics Components Hydraulic Units... ISO 9001: 2008 EN ISO 14001: 2004 SECURITY SYSTEMS Road Blockers INSTALLATION INSTRUCTIONS SURFACE TYPE HYDRAULIC RISING ROAD BLOCKER INDEX Page 1. GENERAL INFORMATION....3 2. SYSTEM COMPONENTS....5 2.1

More information

INDEX 1. GENERAL INFORMATION SYSTEM COMPONENTS OPERATION INSTRUCTIONS MAINTENANCE... 14

INDEX 1. GENERAL INFORMATION SYSTEM COMPONENTS OPERATION INSTRUCTIONS MAINTENANCE... 14 ISO 9001: 2008 EN ISO 14001: 2004 SECURITY SYSTEMS Bollards INSTALLATION INSTRUCTIONS HYDRAULIC RISING BOLLARDS INDEX 1. GENERAL INFORMATION... 2 Page 2. SYSTEM COMPONENTS... 3 2.1 Construction... 3 2.2

More information

1.GENERAL WARNINGS. Safely keep this handbook for any further consultation INSTALLATION WARNINGS

1.GENERAL WARNINGS. Safely keep this handbook for any further consultation INSTALLATION WARNINGS ISO 9001: 2008 EN ISO 14001: 2004 SECURITY SYSTEMS Turnstiles INSTALLATION INSTRUCTIONS E100 / V100 / V200 / V300 / V400 / V500 SERIES TRIPOD TURNSTILES C100 SERIES CORRIDOR TYPE MOTORIZED TURNSTILES M100

More information

ROAD BLOCKERS BOLLARDS ARM BARRIERS TYRE KILLERS.

ROAD BLOCKERS BOLLARDS ARM BARRIERS TYRE KILLERS. ROAD BLOCKERS BOLLARDS ARM BARRIERS TYRE KILLERS www.ozak-t.com About us OZAK, founded in 1974, is the first and leading pedestrian and vehicle passage control systems manufacturer in Turkey. ÖZAK s manufacturing

More information

RISING BOLLARDS SECURITY BARRIERS

RISING BOLLARDS SECURITY BARRIERS RISING BOLLARDS SECURITY BARRIERS GateSet GSB5000 Series Hydraulic Rising Bollards Systems are designed to provide secure solutions for vehicle access control and regulation of city traffic. With its powerful

More information

TECHNICAL DATA HYDRAULIC UNIT

TECHNICAL DATA HYDRAULIC UNIT GB INSTRUCTIONS MANUAL RISING BOLLARD OIL-HYDRAULIC AUTOMATION COMPONENTS strabuc 918 RELEASE KEY PLUG FOR RELEASE HOLE BOLLARD COVER 12 V WARNING LIGHTS REFLECTORS COMPLETELY RETRACTABLE POST WITH ELECTROPHORESIS

More information

Automatic concealed bollards 275 H600 and 275 H800 with pit

Automatic concealed bollards 275 H600 and 275 H800 with pit Automatic concealed bollards 275 H600 and 275 H800 with pit Technical installation manual CE Declaration of conformity Warnings for the installer Bollard technical data Preparing and installing the bollard

More information

Securitex SBR120 & SBR121 Road Blocker

Securitex SBR120 & SBR121 Road Blocker Securitex SBR120 & SBR121 Road Blocker Technical Manual Securitex Electronic Systems Engineering Traffic Security Engineering division 2005-10-16 0 Introduction The Securitex Road blocker SRB120 and SRB121

More information

INSPECTIONS AND MAINTENANCE

INSPECTIONS AND MAINTENANCE GB INSTRUCTIONS MANUAL STRABUC 930 ARMOURED OIL-HYDRAULIC RISING BOLLARD COMPONENTS strabuc 930 RELEASE KEY PROTECTION PLUG TO ACCESS RELEASE HOLE BOLLARD COVER 12V WARNING LIGHTS REFLECTORS RISING POST

More information

SHALLOW MOUNT ROAD BLOCKER/MODEL SHIELD

SHALLOW MOUNT ROAD BLOCKER/MODEL SHIELD /MODEL SHIELD Technical information: Solid steel construction with hot dib galvanized & RAL coating. Width: Height: Construction height: Electrical engine: Electrical system: Operating time: Operating

More information

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional - Oleodinamica BAYT 980 Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL POLO 44 - optional - BAYT 980 560 code 4425 Post with fixing base the gate opener Made in Italy INSTALLATION MANUAL GB INSTRUCTIONS

More information

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind) Barrier Gate Manual (DZX2. Control Board) (The third version) (Pictures for reference only, the product prevail in kind) Contents. Brief Introduction... 2. Functions and Features... 3. Technical Data...2

More information

INSTALLATION MANUAL (cod )

INSTALLATION MANUAL (cod ) is a bollard designed for the management of traffic areas, parkings and protection of public and private accesses. It has an hydraulic system is engineered in our factory to achieve minimum noise and maximum

More information

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a bi-directional wafer valve equipped with two metallic coved rubber sleeves designed for use in the handling of abrasive slurries, mainly in industries

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a bi-directional wafer valve equipped with two metallic coved rubber sleeves designed for use in the handling of abrasive slurries, mainly in industries

More information

KAVASS SECURITY TECH LIMITED

KAVASS SECURITY TECH LIMITED KAVASS SECURITY TECH LIMITED Tel:+86-571-88690663 Email: info@ikavass.com Web: www.ikavass.com Head office: 6th F, T5 EFC, 89# Lianchuang St.,Yuhang Dist., Hangzhou Zhejiang China. Factory: 46# Tianyang

More information

Dry installed pump type LANDY BTP.

Dry installed pump type LANDY BTP. OPERATION & MAINTENANCE MANUAL Dry installed pump type LANDY BTP. Landustrie Sneek BV Pieter Zeemanstraat 6 Tel. 0031 515-486888 P.O. BOX 199 Fax. 0031 515-412398 NL-8600 AD Sneek info@landustrie.nl The

More information

PROCUREMENT SPECIFICATION MODEL TT210 BOLLARD HYDRAULIC BARRICADE SYSTEM

PROCUREMENT SPECIFICATION MODEL TT210 BOLLARD HYDRAULIC BARRICADE SYSTEM PROCUREMENT SPECIFICATION MODEL TT210 BOLLARD HYDRAULIC BARRICADE SYSTEM 1.0 SCOPE The specification defines the procurement of a BOLLARD HYDRAULIC BARRICADE SYSTEM, Model TT210, consisting of (one, two,

More information

Carlift Series PHP 220F

Carlift Series PHP 220F PHP 220F Hydraulic Car Lift / Console Type Without Pit The easiest solution to access parking floors. Load capacity: max. 2.00 kg, wheel load 2 kg Optional Load capacity: max..000 kg, wheel load 70 kg

More information

SPEEDROLLER SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL. Edition : May 2011

SPEEDROLLER SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL. Edition : May 2011 SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL SPEEDROLLER Edition : May 2011 1 8 2 3 4 Main components 1 drive 2 wind roller with hood (optional) 3 door panel 4 aluminium hinge profile 5 window section

More information

Oil-hydraulic operator for swinging gates

Oil-hydraulic operator for swinging gates COMBI 740 Oil-hydraulic operator for swinging gates Below ground Version with two-way locking device Version with brake in open/close cycles Version with 110 and 175 shaft rotation Instruction manual GB

More information

NMSB XX K12 Sliding Crash Gate

NMSB XX K12 Sliding Crash Gate NMSB XX K12 Sliding Crash Gate The Nasatka Maximum Security Barrier NMSB XX (pronounced 20) is a DOS listed K12 cantilevered sliding crash gate engineered for high-threat security facilities. The gate

More information

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,

More information

CONTENTS. Road blocking systems Bollards... Road Blocker... Speed Bump... Tire-Killer & Control Plates...

CONTENTS. Road blocking systems Bollards... Road Blocker... Speed Bump... Tire-Killer & Control Plates... ROAD BLOCKERS Being a member of «TSM Group» Corporation, TiSO produces a variety of products including all types of turnstiles, gates, emergency exit doors, blocking, anti-ram systems, and fire-resistant

More information

BOVIBOOSTER WDone & WDtwo

BOVIBOOSTER WDone & WDtwo BOVIBOOSTER WDone & WDtwo User Guide BBWDone BBWDtwo PowerDos15 D2NBAx D2NBDL Always wear suitable protective equipment when working on the BOVIBOOSTER Always disconnect the electrical supply when working

More information

T E C H N I C A L S P E C I F I C A T I O N WORKSHOP LUBRICATION TRUCK

T E C H N I C A L S P E C I F I C A T I O N WORKSHOP LUBRICATION TRUCK 11350 T E C H N I C A L S P E C I F I C A T I O N WORKSHOP LUBRICATION TRUCK High Quality Product - MADE IN GERMANY Custom-made According to customer-specific requirements The Mobile Workshop can be used

More information

BARRY BARRIER GATE AUTOMATION

BARRY BARRIER GATE AUTOMATION BARRY BARRIER GATE AUTOMATION Installation Manual 1. WARNINGS AND GENERAL SAFETY INSTUCTIONS This manual contains important safety information. An incorrect installation or an improper use may cause serious

More information

BioJet 2100C. 1. Introduction 2

BioJet 2100C. 1. Introduction 2 Contents 1. Introduction 2 2 Warnings and important notes 3 2.1 Safety rules concerning the delivery device MS-60 3 2.2 Safety rules concerning the vacuum filter unit model P2 3 2.3 Safety rules concerning

More information

6L Oil-less Air Compressor 53103

6L Oil-less Air Compressor 53103 6L Oil-less Air Compressor 53103 Operating Instructions Please read and save these instructions before attempting to assemble, install, operate or maintain the product. Protect yourself and others by observing

More information

HYDRAULIC GROUPS 1.1KW 1~ / 6.1CC. Article Code: 1GH008

HYDRAULIC GROUPS 1.1KW 1~ / 6.1CC. Article Code: 1GH008 TECHNICAL MANUAL FOR HYDRAULIC GROUPS 1.1KW 1~ / 6.1CC WITH NEGATIVE SECURITY Article Code: 1GH008 THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE

More information

MST. model. alvaradomfg.com

MST. model. alvaradomfg.com alvaradomfg.com FULL HEIGHT TURNSTILES model The is the most trusted, secure and reliable full height turnstile available. It is installed in thousands of locations around the world and offers key product

More information

Kentaur Road Barriers

Kentaur Road Barriers Kentaur Road Barriers «We have installed Kaba Road Barriers to secure our premises. They allow for flexible and efficient management of access authorisation for both pedestrians and vehicles. The new units

More information

USER MANUAL MPS 1-5KW SERIES

USER MANUAL MPS 1-5KW SERIES USER MANUAL MPS 1-5KW SERIES Low Series Frequency Solar and Wind Power Charging Inverter CONTENTS 1 WWW.NEXTGENNRG.COM 1. Introduction... 3 2. Profile Structure 4 2.1. Working Principle 4 2.2.Product Features..5

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a bi-directional full flanged valve equipped with two metal reinforced rubber sleeves designed for use in the handling of abrasive slurries, mainly

More information

PROCUREMENT SPECIFICATION MODEL TT207S/FM PHALANX* SURFACE MOUNT HYDRAULIC BARRICADE SYSTEM

PROCUREMENT SPECIFICATION MODEL TT207S/FM PHALANX* SURFACE MOUNT HYDRAULIC BARRICADE SYSTEM PROCUREMENT SPECIFICATION MODEL TT207S/FM PHALANX* SURFACE MOUNT HYDRAULIC BARRICADE SYSTEM 1.0 SCOPE This specification defines the procurement of a PHALANX* HYDRAULIC BARRICADE SYSTEM, Model TT207S/FM,

More information

UNIDIRECTIONAL Knife Gate Valve

UNIDIRECTIONAL Knife Gate Valve 12/04/2016 UNIDIRECTIONAL Knife Gate Valve Unidirectional knife gate valve. Mechanically welded body. Various seat and packing materials available. Face to face dimension in accordance with standard, it

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a bi-directional full flanged valve equipped with two metal reinforced rubber sleeves designed for use in the handling of abrasive slurries, mainly

More information

Installation Instructions

Installation Instructions Installation Instructions MX3635-01 Rev. E Models HydraSwing 40s HydraSwing 40F 4,000 lb (1,814 kg) 10-15 seconds HydraSwing 40 4,000 lb (1,814 kg) 15-20 seconds HydraSwing 40 Twin 4,000 lb (1,814 kg)/leaf

More information

Typical applications are the control of barriers/booms in the parking and access control environments.

Typical applications are the control of barriers/booms in the parking and access control environments. Barrier Logic Model - BL110B The BL110B is a barrier logic unit which has been developed to control barriers using magnetic motors with ease of installation. The BL110B accepts inputs from card readers

More information

PANcharge1k Battery Charger User's Manual

PANcharge1k Battery Charger User's Manual PANcharge1k Battery Charger User's Manual Ver.1.00E Table of Contents 1. Important Safety Instructions... 3 1-1 General Safety Precautions... 3 1-2 Battery Precautions... 3 1-3 Electromagnetic Disturbance...

More information

Barrier. Delimitation car height lower level car height lower level

Barrier. Delimitation car height lower level car height lower level KLAUS Multiparking GmbH Hermann-Krum-Straße 2 D-88319 Aitrach Fon +49 (0 ) 75 65 5 08-0 Fax +49 (0 ) 75 65 5 08-88 info@multiparking.com www.multiparking.com PRODUCT DATA Outdoor Grounding 5 520 for vehicle

More information

Ropox Shower & Changing Bed

Ropox Shower & Changing Bed Ropox Shower & Changing Bed Pre-install / install guide General information Product information It is important to read this manual before mounting and daily use. Product : Ropox Shower & Changing Bed,

More information

StrongArmCRASH M30 ( K4) M50 ( K12) Patent Pending. Patent Pending

StrongArmCRASH M30 ( K4) M50 ( K12) Patent Pending. Patent Pending CRASH StrongArmCRASH TM M30 ( K4) Patent Pending M50 ( K12) Patent Pending StrongArmCRASHTM ULTIMATE HARDENED SECURITY StrongArm M30 & M50 take barrier arms to the extreme. These machines stop a 15,000

More information

PowerLink GW series Eddy Current Dynamometer User Manual

PowerLink GW series Eddy Current Dynamometer User Manual PowerLink GW series Eddy Current Dynamometer User Manual XiangYi (Hong Kong) Power Testing Instrument Co. Ltd. 0 GW Series Eddy Current Dynamometer User Manual Transport, Storage, use of environmental

More information

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm) ALVARADO EDCX Bullnose Waist High Turnstile Technical Specifications Dimensions Unit Height: Unit Width: Unit Depth: 40.5 (1029 mm) 25 (635 mm) 36.5 (927.1 mm) Materials Cabinet: Formed and welded 14 gauge

More information

TURNSTILES REVOLVING DOORS SPEEDGATES PRESTIGE TURNSTILES

TURNSTILES REVOLVING DOORS SPEEDGATES PRESTIGE TURNSTILES TURNSTILES REVOLVING DOORS SPEEDGATES PRESTIGE TURNSTILES ISO 9001:2015 2017 COMPANY PROFILE Established in 1990, Turnstar provides a total solution for all physical access control and time & attendance

More information

EDC-E. Waist HIGH Turnstiles. alvaradomfg.com

EDC-E. Waist HIGH Turnstiles. alvaradomfg.com Waist HIGH Turnstiles alvaradomfg.com Descriptive SPECIFICATIONS The is an extended length cabinet turnstile with extended length turnstile arms. It is a rugged, multi-purpose turnstile used to provide

More information

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS SLIDING GATE OPENER DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS The strongest solution for sliding gates PL600/PL1000 electro-mechanical sliding gate openers are designed

More information

CAUTION CM-SE CM-S21 CM-S41

CAUTION CM-SE CM-S21 CM-S41 CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and

More information

PRODUCT DATA kg

PRODUCT DATA kg Car KLAUS Multiparking GmbH Hermann-Krum-Straße D- Aitrach Fon + (0 ) 0-0 Fax + (0 ) 0- info@multiparking.com www.multiparking.com PRODUCT DATA 000 kg Garage without door (basement garage) 0 0 0 Free space

More information

pneumatic outflow control

pneumatic outflow control Technical Information pneumatic outflow control Pneumatically driven control elements for precise flow limitation of wastewater and rainwater partly filled pneumatic outflow control IDM-based fully filled

More information

USER MANUAL FOR AUTOMATIC A/C CHARGING STATIONS

USER MANUAL FOR AUTOMATIC A/C CHARGING STATIONS USER MANUAL FOR AUTOMATIC A/C CHARGING STATIONS Nano Nano 2 Nano Hybrid ITECH Creative Technology INDEX 1 INTRODUCTION... 2 1.1 Safety instructions... 2 2 EQUIPMENT... 2 3 USE... 4 3.1 Control panel...

More information

Hand pump PUMP1000-4L-CONTROL. User manual

Hand pump PUMP1000-4L-CONTROL. User manual Hand pump PUMP1000-4L-CONTROL User manual Safety guidelines and symbols High product safety Follow instructions Definition of guidelines and symbols Warning Caution Our products correspond to the current

More information

(1032 mm) 30.5 (775 mm) 44 ( mm)

(1032 mm) 30.5 (775 mm) 44 ( mm) ALVARADO EDCX-EK Waist High Turnstile Technical Specifications Dimensions Unit Height: Unit Width: Unit Depth: 40.625 (1032 mm) 30.5 (775 mm) 44 (1117.6 mm) Materials Cabinet: Formed and welded 14 gauge

More information

INSTALLATION MANUAL GB

INSTALLATION MANUAL GB GB INSTALLATION MANUAL @GB; 66 FITTING INSTRUCTIONS Important: Keep to the instructions outlined in the pages and diagrams that follow to achieve a perfect installation. NUPI 66 is an oil-hydraulic actuator

More information

AUTOBREN ROAD SWEEPER TS7 DESCRIPTIVE DATA SHEET REV

AUTOBREN ROAD SWEEPER TS7 DESCRIPTIVE DATA SHEET REV AUTOBREN ROAD SWEEPER TS7 DESCRIPTIVE DATA SHEET REV. 14.02.2014 1. GENERAL VEHICLE INFORMATIONS - Suitable vehicle to operate on road and apron with chassis of commercial origin; -Collection system exclusively

More information

Operating Instructions Type MPT 53

Operating Instructions  Type MPT 53 Operating Instructions www.turnstiles.us Type MPT 53 Contents 1. Delivery... 2 2. Safety...3-4 3 Description and operation... 5 4. Technical Data 6 5. oundation...6-9 6. Assembly and installation...10-13

More information

1-24. Oil-hydraulic. Oil-hydraulic road barrier for traffic control from 3 to 8 metres

1-24. Oil-hydraulic. Oil-hydraulic road barrier for traffic control from 3 to 8 metres GB Instructions manual pages 1-24 Oil-hydraulic Oil-hydraulic road barrier for traffic control from 3 to 8 metres Stainless steel and painted versions Version with aluminium fence Version with articulated

More information

GB Instructions Manual

GB Instructions Manual GB Instructions Manual pages - 8 CMYK- 0 0 KYMC- 0 0 KYMC- 0 0 0 KYMC- 8 KYMC- 0 KYMC- 0 0 0 KYMC- 0 0 0 0 Underground oil-hydraulic operator for swinging gates or 7 shaft rotation Compact all-in-one oil-hydraulic

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC) SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC) TABLE OF CONTENTS 1 EC Declaration of incorporation...1 2 General description...2

More information

MST FULL HEIGHT TURNSTILES TYPICAL INSTALLATION SITES COMMON APPLICATIONS DESCRIPTIVE SPECIFICATIONS ALVARADOMFG.COM

MST FULL HEIGHT TURNSTILES TYPICAL INSTALLATION SITES COMMON APPLICATIONS DESCRIPTIVE SPECIFICATIONS ALVARADOMFG.COM DESCRIPTIVE SPECIFICATIONS The is the most trusted, secure and reliable full height turnstile available. It is installed in thousands of locations around the world and offers key product features and benefits

More information

Plunger Heads Use and Maintenance Manual

Plunger Heads Use and Maintenance Manual Plunger Heads Use and Maintenance Manual UK Positive displacement dosing pump Type PDP Series A-I 175 A-I 250 A-I 350 General instructions We thank you for choosing this product and recommend you read

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES P G 036-21342-002 Rev. C (0902) TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) U R MA N U F A CT R E C E CE R T I F R T I UN I TA RY A R I F I

More information

VEHICLE AND PEDESTRIAN CONTROL

VEHICLE AND PEDESTRIAN CONTROL VEHICLE AND PEDESTRIAN CONTROL Jacksons design and manufacture a wide range of gates in steel, timber or a combination of both to safe guard the continued security of any installation. Regardless of the

More information

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Product Catalog NQ Series Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Page Intentionally Blank Contents Standard Features...1 Available Options...3 Oversized Pumps... 3 High Flow Unit

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

INSTRUCTION MANUAL. Air Curtains Rund (M, G)

INSTRUCTION MANUAL. Air Curtains Rund (M, G) INSTRUCTION MANUAL Air Curtains Rund (M, G) SECURITY ADVISE SIMBOLS Attention, Danger, Safety Advice! Danger from electric current of high voltage! Injuries risk! Danger! Do not step underneath: Heavy

More information

GLM SERIES CONTROL Users Manual Rev:

GLM SERIES CONTROL Users Manual Rev: GLM SERIES CONTROL Users Manual Rev: 808062 Connecting Power Page 2 Motor Terminal Wiring Diagrams Page 3 Getting Started / Setup Page 4 1. Obstruction Detection Devices Page 4 2. Checking Power and Direction

More information

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

Operator's Manual. Models (¾) (1) (1½ ) (2 ) (3) (4) (6) (8) OdisMatic Hydraulic Filter Series 851 Operator's Manual Models 85107 (¾") 85101 (1") 85115 (1½ ) 85102 (2 ) 85103 (3") 85104 (4") 85106 (6") 85108 (8") Content 1. Technical Specifications. 2. Materials.

More information

T E C H N I C A L S P E C I F I C A T I O N

T E C H N I C A L S P E C I F I C A T I O N 11340 T E C H N I C A L S P E C I F I C A T I O N TANK BODY for save transportation of diesel and petrol (gasoline) Volume: approx. 16.000 ltr. incl. 3% expansion High Quality Product MADE IN GERMANY 100%

More information

[Small diaphragm vacuum pumps]

[Small diaphragm vacuum pumps] [Small diaphragm vacuum ] The small vacuum shown on this page produce vacuum using a diaphragm. They can be used either as vacuum pump or as a small compressor, and they are able to deliver 100% oil-free

More information

Quadro Outdoor T2 S/D

Quadro Outdoor T2 S/D Quadro Outdoor T2 S/D Our solution for high demands outdoor operation no columns or any other barrier in the area of the doors Made in Germany Areas of application: private houses, residential buildings,

More information

CHECKING AND MAINTENANCE:

CHECKING AND MAINTENANCE: GB INSTALLATION MANUAL APROLI 480 OIL-HYDRAULIC OPERATOR FOR GARAGE DOORS SECTION VIEW OF THE OIL-HYDRAULIC OPERATOR WITH LAMP AND COVER UPPER SECTION SUPPORT LAMP REFLECTOR LIGHT DIFFUSION COVER 230 V-25

More information

Manual pneumatic operated valves for fixed installations, CO2 and inert gases. Series B0430

Manual pneumatic operated valves for fixed installations, CO2 and inert gases. Series B0430 Manual pneumatic operated valves for fixed installations, CO2 and inert gases B B0430 Working pressure p max. 250 bar Temperature range - 20 C + 60 C Seat orifice size 12 mm Material Valve body brass Inlet

More information

PNEUMATIC PUMP Series

PNEUMATIC PUMP Series PNEUMATIC PUMP Series 3103... User and Maintenance Manual Original text translation TABLE OF CONTENTS 1. INTRODUCTION 2. GENERAL DESCRIPTION 3. PRODUCT-MACHINE IDENTIFICATION 4. TECHNICAL CHARACTERISTICS

More information

TRAFFIC AND PARKING SYSTEMS SPIKES, BARRIER GATES AND COMPONENTS

TRAFFIC AND PARKING SYSTEMS SPIKES, BARRIER GATES AND COMPONENTS TRAFFIC AND PARKING SYSTEMS SPIKES, BARRIER GATES AND COMPONENTS Your comprehensive product offering for traffic and parking applications. TRAFFIC AND PARKING SYSTEMS PRODUCT LINE SPIKES, BARRIER GATES

More information

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS SECTION 08350 HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1

More information

ARKAL SCREEN LINE H - SERIES Hydraulically Operated Self-Cleaning Screen Filter SERVICE & MAINTENANCE MANUAL

ARKAL SCREEN LINE H - SERIES Hydraulically Operated Self-Cleaning Screen Filter SERVICE & MAINTENANCE MANUAL ARKAL SCREEN LINE H - SERIES Hydraulically Operated Self-Cleaning Screen Filter SERVICE & MAINTENANCE MANUAL Table of Contents Subject Page No. Introduction... 2 Safety Instructions... 3 Description &

More information

E R A I GATE AUTOMATION DIVISION

E R A I GATE AUTOMATION DIVISION S E R A I GATE AUTOMATION DIVISION INSTALLATION MANUAL MC/5C - 03.5C UNDERGROUND MOTOR 230 Vac FOR WING GATES UP TO 3,00m AND 300 Kg EACH WING + FOUNDATION BOX IN HOT-GALVANISED STEEL Thank you for choosing

More information

AUTOMATIC CONTROL VALVES. TIS asia

AUTOMATIC CONTROL VALVES. TIS asia AUTOMATIC CONTROL VALVES VALVES DEDICATED TO THE WATER DISTRIBUTION NETWORK AND HYDROPOWER SECTOR WE DO NOT SELL JUST VALVES, WE SELL A SOLUTION FOR THE EFFICIENCY OF THE WATER NETWORK TIS asia MADE IN

More information

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION SERIES 1000-X OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION Publication S1000X-110 VER0215-1 For information on this product and

More information

SECTION LIFT ARM PARKING GATES

SECTION LIFT ARM PARKING GATES St. Anthony of Padua Catholic Church Phase I The Woodlands, Texas JRA Proj. No. 15004 Issued for Bidding - 1/20/2016 SECTION 11 12 33.13 LIFT ARM PARKING GATES PART 1 - GENERAL 1.01 SUMMARY A. Section

More information

10AC DIPLOMAT SERIES RFC SYSTEMS

10AC DIPLOMAT SERIES RFC SYSTEMS 10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA

More information

PROCUREMENT SPECIFICATION MODEL TT207S PHALANX* TYPE HYDRAULIC BARRICADE SYSTEM

PROCUREMENT SPECIFICATION MODEL TT207S PHALANX* TYPE HYDRAULIC BARRICADE SYSTEM 1.0 SCOPE PROCUREMENT SPECIFICATION MODEL TT207S PHALANX* TYPE HYDRAULIC BARRICADE SYSTEM This specification defines the procurement of a PHALANX* HYDRAULIC BARRICADE SYSTEM, Model TT207S, consisting of

More information

VAL6 KBE5S. Service Manual

VAL6 KBE5S. Service Manual VAL6 KBE5S Service Manual 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel Tank Capacity 9 gallons Fuel Consumption 0.85gallon/h Power Source 120V, 60Hz single phase Power

More information

SPECIAL SPECIFICATION 5273 Dragnet Vehicle Arresting Barrier

SPECIAL SPECIFICATION 5273 Dragnet Vehicle Arresting Barrier 2004 Specifications CSJ 2374-01-153, etc. SPECIAL SPECIFICATION 5273 Dragnet Vehicle Arresting Barrier 1. Description. This Item governs for the furnishing and installation of Dragnet Vehicle Arresting

More information

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual NYOTA 115 Electro-mechanical sliding gate operator Instruction manual GB INSTRUCTIONS FOR THE INSTALLATION OF THE AUTOMATION NYOTA 115 FOR A CORRECT INSTALLATION AND GOOD PERFORMANCE OF NYOTA 115 READ

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

S3 General Installation

S3 General Installation Wilfley Drylock Assembly General Installation Operating & General Servicing Clearance Settings Safety Precautions Spare Parts Ordering Assembly Instructions Model S3 General Installation Inspection upon

More information

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11 Part A, Section 3 This section covers the following unit configurations. Model All Voltage 1, 2, 3 Pump All Manifold All Control Vista Standard (V) A 3-0 A 3-1 Section A 3 WARNING: Allow only qualified

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Head with piston Use and Maintenance Manual

Head with piston Use and Maintenance Manual Head with piston Use and Maintenance Manual UK Type Positive displacement dosing pump PDP Series A-I 175 A-I 250 A-I 350 General instructions We thank you for choosing this product and recommend you read

More information

SIMPLEX BIG 2B PARTS WASHERS WITH ROTARY BASKET, PLC AND TOUCHSCREEN EQUIPMENT SIMPLEX BIG 2B

SIMPLEX BIG 2B PARTS WASHERS WITH ROTARY BASKET, PLC AND TOUCHSCREEN EQUIPMENT SIMPLEX BIG 2B SIMPLEX BIG 2B PARTS WASHERS WITH ROTARY BASKET, PLC AND TOUCHSCREEN Simplex Big is a system ideal for the automatic washing of medium and large size mechanical parts. The washing is carried out by the

More information

6 Litre Oil-Less Air Compressor

6 Litre Oil-Less Air Compressor Operator s Manual 6 Litre Oil-Less Air Compressor WARNING! Before using this appliance, read the Operator s manual and follow all its safety rules and instructions. SPECIFICATION HWKAC1 1.1 kw / 1.5 HP

More information

INSTALLATION M ANUAL

INSTALLATION M ANUAL INSTALLATION MANUAL Table of Contents UL Listings Installing the Warning Sign / Precautions Methods of Installation / Compact Installation Mounting the Secondary Entrapment / Welding Gate Arn Mounting

More information

MODEL 890 SERIES SURFACE MOUNTED VEHICLE BARRICADE

MODEL 890 SERIES SURFACE MOUNTED VEHICLE BARRICADE MODEL 890 SERIES SURFACE MOUNTED VEHICLE BARRICADE OPERATIONS & MAINTENANCE MANUAL Corporate Office & Tech Support: 5900 S. Lake Forest Drive, Suite 230 McKinney, TX 75070 Phone: (972) 385-7899 Toll Free:

More information

A408 GB. Pneumatic oil and diesel pumps 1:1

A408 GB. Pneumatic oil and diesel pumps 1:1 03 594 A408 GB Pneumatic oil and diesel pumps 1:1 G Operating instructions for Pneumatic oil and diesel pump 1:1 Contents 1. General details 2 1.1 Intended use 2 1.2 Design and functional description 2

More information