1 GB INSTALLATION MANUAL

2 APROLI 480 OIL-HYDRAULIC OPERATOR FOR GARAGE DOORS SECTION VIEW OF THE OIL-HYDRAULIC OPERATOR WITH LAMP AND COVER UPPER SECTION SUPPORT LAMP REFLECTOR LIGHT DIFFUSION COVER 230 V-25 W LAMP SCREW SEAT FOR FIXING THE COVER/UPPER SECTION ELECTRIC TERMINAL COVER OIL CONTAINER ELECTRIC TERMINALS ELECTRIC MOTOR TOP END CAP FADINI OIL A 15 BY AGIP HYDRAULIC LOBE PUMP S AIR BLEED SCREW O.33 HP ELECTRIC MOTOR OIL RESERVOIR TWO-WAY LOCKING VALVE PRESSURE VALVE ASSEMBLY C A B FADINI OIL A 15 BY AGIP MANUAL RELEASE LEVER TWO-WAY LOCKING VALVE ASSEMBLY PISTON SLEEVE FADINI OIL A 15 BY AGIP GEAR BOX HOUSING 1 st PISTON WITH STEEL INSERT TOOTHED SHAFT SHAFT SUPPORT SPACER BEARING/ GEAR TEETH RACK COVER 2 nd PISTON WITH STEEL INSERT SCREW SEAT FOR FIXING THE COVER/BOTTOM END FADINI OIL A 15 BY AGIP BOTTOM SECTION CYLINDER END CAP PIC. 1 2

3 INSTRUCTIONS FOR THE INSTALLATION OF APROLI 480 TO A GARAGE DOOR WITH COUNTERWEIGHTS WEATHER STRIP DOOR HANDLE WALL FRAME DOOR JAMB COUNTERWEIGHT WHEEL DOOR UPPER EDGE GARAGE DOOR GUIDE ARM TELESCOPIC ARM LATERAL SUPPORT COUNTERWEIGHT COUNTERWEIGHT CASE WEATHER STRIP APROLI 480 WITH COVER BOTTOM DOOR WHEEL WEATHER STRIP 100x5 mm REINFORCEMENT PLATE TO BE FIXED TO THE DOOR FRAME FIXING BRACKET M PIC. 2 No change to the existing door is required for the installation of this operator. Automatic or semi-automatic operations. Hand operation can be made possible by releasing the system through the lever B both from inside or outside the building. (Pic.1) ESSENTIAL COMPONENTS FOR THE APPLICATION OF THE OPERATOR ON TO A GARAGE DOOR HAVING COUNTERWEIGHT (PIC.3) TERMINAL BOARD COVER TELESCOPIC ARM AIR BLEED S TRANSMISSION BAR WITH SHAFT FITTING SLEEVE (SQUARE HOLE) WELDED TO IT TELESCOPIC ARM MAX. PRESSURE SAFETY VALVE OPEN. RED A TRANSMISSION BAR LATERAL SUPPORT FIXING M BRACKET MAX. PRESSURE SAFETY VALVE CLOSE. GREEN C PIC. 3 3

4 It is recommended to follow the drawings in this manual to install APROLI 480 on to garage doors in order to automate them. The operator is designed for the installation in the centre of the existing door by means of a bracket M that is fixed to the door with screws. Pic.4 15 DOOR FRAME WALL FRAME DOOR JAMB DOOR GUIDE ARM OF THE EXISTING DOOR FIXING M COUNTERWEIGHT CASE AND ROLLER GUIDE TUBE PERPENDICULARLY FITTED REINFORCEMENT PLATE 100x5 mm PIC. 4 Should the upper and lower fixing ends of the bracket M not coincide with the upper and lower edges of the door, it is recommended to rivet, screw or spot weld an iron reinforcement plate (100 mm - 5 mm thickness) vertically across the door so to connect the top and bottom edges of the door as shown in pic TELESCOPIC ARM TO BE PARALLEL FIXED TO THE EXISTING DOOR ARM 20 FIXING PLATE TO WELD REINFORCEMENT OPEN APROLI 480 CLOSED DOOR POSITION 100 x 5 DOOR JAMB/ COUNTERWEIGHT CASE PIC. 5 Once the bracket M has been fixed, it is to be determined whether the telescopic arms are to overlap the existing door arms or be fixed parallel to them. See pic. 5 and 6. Then proceed to weld the fixing plates as indicated by the distances in pic.5 4

5 40 40 TELESCOPIC ARM OVERLAPPING THE DOOR ARM WHEN THERE IS NO SPACE BETWEEN ARM AND COUNTERWEIGHT 5 EXISTING GUIDE ARM FIXING ABOVE THE ARM PIVOT FIXING ON TO THE GUIDE ARM OPERATOR IN THE OPEN POSITION 40 BRACKET M TELESCOPIC ARM OVERLAPPING THE DOOR ARM WHEN THERE IS NO SPACE BETWEEN ARM AND COUNTERWEIGHT 10 FIXING ON TO THE GUIDE ARM PIC. 6 Once the bracket and the operator have been fixed to the door, proceed to temporarily fix the two telescopic arms to the torsion shaft, considering that the shaft must be allowed to rotate 5 degrees less than the end of the permitted stroke, as further explained in pic.7 END OF PISTON STROKE WHEN NO FURTHER TURNING IS ALLOWED HYDRAULIC LOCKING/ UNLOCKING LEVER B ROTATE IN THE ARROW DIRECTION BY 5 mm TO GET mm PIC. 7 Rotate the shaft to the end of the permitted stroke by means of pliers. Then rotate the shaft back by 5 mm. This allows more power to the operator when it is required to close the door. Pic. 7. Please note the door must be in closed position when this operation is done. 5

6 CLOSED DOOR FIXING PLATE TELESCOPIC ARM B LEVEL LEVEL LATERAL SUPPORT LATERAL SUPPORT PROVIDED WITH THE EQUIPMENT TORSION BAR PIC. 8 Fit the two telescopic arms to the torsion bars and make sure that they are perfectly perpendicular to them at the same distance from the door. Adjust the two supports to achieve the above and put some wooden spacers to bring the lateral supports to the required distance. A spirit level will ensure that the torsion bars are perfectly horizontal. See pic. 8. The lever «B» must be in the released position. FIXING PLATE TELESCOPIC ARM WITH SLIDING BAR TELESCOPIC ARM WITH SLIDING BAR CUT TO MEASURE AND WELD LEVEL LEVEL CUT TO MEASURE AND WELD LATERAL SUPPORT TORSION BAR WITH SLEEVE CIRCULAR WELDING PIC. 9 Fit the two telescopic arms and the torsion bars in the correct position and make sure that they are levelled and parallel, door in the closed position. Partially weld the torsion bars to the lifting arms and operate the door by hand. Verify that it can open fully in a quiet and smooth way. The lever «B» in the released position. Pic.8. 6

7 Once satisfied that the installation is correct and smooth, remove the two torsion bars and the sliding bars in order to firmly fix them by welding all around. Pic.9 FIX THE COVER ONLY AFTER COMPLETING THE INSTALLATION IN THIS POSITION THE DOOR MUST BE WELL BALANCED. SHOULD IT NOT, ADD SOME EXTRA COUNTERWEIGHT 45 PIC. 10 A good test to verify how well balanced the door is in both directions, ie. lifting and lowering, is to position it 45 degrees from ground level, as shown in picture 10. Add counterweight to improve running smoothness and balance if required. MAXIMUM PRESSURE VALVE OPEN RED IN COLOUR A S B AIR BLEED RELEASE LEVER TURN IT ANTI-CLOCKWISE The two safety pressure valves are identified by colours: «A» Open is red; «C» close is green. They are located in the front of the motor/pump unit, easy to reach for setting operations in order to meet the power requirements.pic.11 Once the valves are set, you can fit the cover and the other accessories. Pic.10 MAXIMUM PRESSURE VALVE CLOSE GREEN COLOUR C MORE POWER LESS POWER The setting of the safety pressure valves is to be done so to achieve the exact amout of power required to safely operate the door. The more you turn the screw clockwise, the more you increase the power of the operator. PIC. 11 7

8 RELEASE LEVER B RUBBER STOP OPEN RECOMMENDED STARTING POSITION BEFORE CLOSE CYCLE RUBBER STOP 25 RUBBER STOP ON THE OUTSIDE OF THE DOOR PIC. 12 The highest power is required to start the close cycle. Therefore it is recommended to fit rubber stops to the door. This will cushion the door at the end of the up stroke and will keep the door inclined by 5 degrees for a better start. See Pic.12. RELEASE LEVER CLAMP B LOCKABLE HATCH DOOR RELEASE CORD DOOR SECTION To release Aproli 480 for hand operations it is available a device as described above, on request. Turn the key sharply; this will pull the cord and the lever open. As an option you can fit the door with a service hatch. Pic.13 HATCH RELEASE LEVER DOOR FROM OUTSIDE PIC. 13 There are two solutions to get access to the operator release lever for hand operations of the door. Either a lock is fitted at a suitable distance from the release lever, to which it is connected by a steel flexible cord as in Pic.13; or a 12 cm x 12 cm lockable hatch is provided and fitted to allow a hand to pass from outside to inside and release the lever «B». 8

9 The electric cable which supplies power to the motor/pump is connected by means of terminals, which are located above the oil container, next to the earth screw connection. The cable must be led along the door to the point where the telescopic arm is welded to the bar. It is recommended that the cable is allowed to dangle free by 130 cm so that the door can go fully up to the end of the permitted stroke. POSITION OF THE EARTH SCREW CONNECTION ELPRO 6 exp CLOSE OPEN APROLI 480 WITH COVER ELECTRIC CABLE TO DANGLE FREE LENGTH 1.30 METRES PIC. 14 COURTESY LIGHT EXTRA CAPACITOR IN CASE OF POWER SHORTAGE OR TO IMPROVE THE POWER OF THE OPERATOR WHEN HEAVY DOORS ARE INVOLVED TO REVERSE THE DIRECTION OF THE SHAFT ROTATION SWOP WIRES ROUND No. 10 AND No. 12 DO NOT CHANGE No.11 PIC ELPRO 6 exp It is essential to make sure that the shaft rotates in the required direction during the first running test. Should it rotate in the opposite direction, change wire No. 10 with No. 12. Pic. 15 9

10 ELECTRICAL WIRING DIAGRAM OF THE OIL-HYDRAULIC GARAGE DOOR OPERATOR APROLI 480 TO THE ELECTRONIC CONTROL PANEL BIRIO A8 AERIAL RADIO CONTROL PLUG-IN CARD SUPPORT 24 V OUTPUT LED ON VOLTAGE SUPPLIED TRANSFORMER FUSE 630 ma meth 8VA 0 24 ASTRO 43/2 RADIO RECEIVER PLUG-IN PC BOARD 1 CHANNEL 1 2 ON OFF MOTOR RUN OPEN & CLOSE TIME DWELL TIME 3 4 ALL OPERATIONS OPEN, STOP & CLOSE RADIO CONTACT 6 exp All the electrical connections to the control panel are to be made as per Drawing 1795 Elpro 6 exp having the following features: terminals for the keyswitch open-stop-close, photocells, safety edge, courtesy light, remote control to terminals 3 & 4 where the first pulse opens the door, the second stops it and the third re-cycles to open or close. 230 V SINGLE-PHASE SUPPLY VOLTAGE 230 V - 25 W MAX. COURTESY LIGHT SINGLE-PHASE MAX. 400W ELECTRIC MOTOR EARTH 24 V OUTPUT A.C. - COURTESY LIGHT FOR TWO MINUTES. ON - FLASHING LAMP. OFF - AUTOMATIC RE-CLOSING. ON - SEMI-AUTOMATIC.OFF Should more pairs of photocells be required than the recommended quantity, fit an auxiliary transformer outside the control box. NOTE WELL: THIS PANEL IS TESTED TO OPERATE GATES ONLY THROUGH FADINI ACCESSORIES. NO GUARANTEE FOR ACCESSORIES OF OTHER MAKE OR SPECIAL APPLICATIONS. MAX. PERMITTED LOAD: 1 PAIR PHOTOCELLS 1 RADIO RECEIVER LIMIT SWITCH. OPEN. N.C. LIMIT SWITCH. COMMON LIMIT SWITCH. CLOSE. N.C. N.O. CONTACT. OPEN SWITCH STOP CLOSE AND RADIO N.C. CONTACT. PHOTOCELLS AND SAFETY EDGE PLUG-IN ASTRO 43 DIP-SWITCH CAPACITOR 12,5 µf M1 FUSES 5 A BUTTON ON THE COVER LID PC BOARD DRWG IT IS ILLUMINATED WHEN VOLTAGE IS SUPPLIED STOP OPEN CLOSE COMMON KEYSWITCH PRIT 19 ELECTRICAL CONNECTIONS KEYSWITCH PRIT 19 PIC COMUNE 230 V - 25 W MAX. FLASHING LAMP

11 0 I.T.F. GARAGE DOOR OPERATOR COMPLETE WITH ALL THE RECOMMENDED ACCESSORIES FOR A GOOD PERFORMANCE VOLTS MAINS SUPPLY R1 R2 R2 R1 ASTRO 43 INNESTO 9 NĊ. C N.A. GND ANT open Amp. CIRCUIT BREAKER 2 - MIRI 4 FLASHING LIGHT 25 Watts FITTED WITH BIRIO A8 AERIAL 3 - PLUG-IN RADIO RECEIVER CARD ASTRO 43 SAW 4 - ELECTRONIC CONTROL BOX Elpro 6 exp 5 - START PUSH BUTTON 6 - KEYSWITCH PRIT SAFETY EDGE. LOW PROFILE 8 - PHOTOCELL TRIFO 11. RECEIVER 9-25 Watt LAMP 10 - OPERATOR APROLI COVER TO PROTECT THE VALVES 12 - FIXING BRACKET 13 - PHOTOCELL TRIFO 11. PROJECTOR 14 - RADIO TRANSMITTER ASTRO 43 TWO BUTTONS 14 PIC

12 SPECIAL GARAGE DOORS SAFETY SWITCH CEI SINGLE-PHASE 1.30 m ELECTRIC CABLE TO DANGLE FREE REINFORCEMENT PLATE 100x5 mm PIC. 18 When very large doors are involved with a service door in the middle, it is recommended to install two operators Aproli 480 on to the door sides without connecting the shaft inner ends. Fixing dimensions and measurements are as explained before in the previous application drawings. It is also recommended to fit the service door with a safety microswitch as shown in pic.18 When two operators are required for one door, it is recommended to install the control panel Elpro 13 CEI and one pair of photocells Trifo 11. These are to be fixed on to the counterweight case 40 cm from ground level. APPLICATION OF APROLI 480 ON A JACK-KNIFE DOOR 6 exp STEP BY STEP UPPER HINGES CENTER HINGES 80 / 100 mm ELECTRIC CABLE LOOP LENGTH 1.30 m SLIDING GUIDE FOR ROLLER REINFORCEMENT PLATE 100 x 5 mm PIC. 19 ROLLER WITH SLIDING GUIDE For jack-knife doors, the same instructions apply as for single-panel doors as explained in the previous pages. Only please note that with articulated doors as the above type, it is recommended to fix the operator so that the shaft and the torsion bars are mm below the door hinge centre line. Pic.19 12

13 APPLICATION OF APROLI 480 ON TO A DOOR WITH UPPER TRACK, FULLY INDOOR UPPER FIXING BY THE SIDE OF THE DOOR SLIDING GUIDE WARNING LAMP ON STARTING WITH RADIO AERIAL UPPER GUIDE COUNTERWEIGHT IN THE MIDDLE OF THE DOOR UPPER ROLLER FOR HORIZONTAL UPPER TRACK COUNTERWEIGHT REINFORCEMENT PLATE 100 x 5 mm LOWER ROLLER SLIDING IN THE LATERAL PERPENDICULAR CASING PIC. 20 WALL FRAME For the installation of Aproli 480 on to garage doors with upper track follow the same instructions as explained before; the shaft ie. the torsion fulcrum must coincide with the centre line of the door, right in the middle between upper and lower guide rollers. See Pic. 20 S UNSCREW BY ONE TURN TO BLEED AIR OUT OF THE OIL TANK IMPORTANT AFTER INSTALLATION APROLI 480 UNDO BY ONE TURN S OIL FADINI A 15 BY AGIP STICKER FITTED TO THE OIL TANK PIC. 21 Please note, once Aproli 480 has been fixed, unscrew the air bleed screw by one turn. This screw is fitted on the cap of the oil container, where the voltage supplying cable is led to the motor. Pic.21 Should the operator «Aproli 480» be removed for maintenance or repairing tighten the screw «S» to prevent oil from coming out during handling. 13

14 UNSCREW LAMP REFLECTOR E PRESSURE SWITCH ELECTRIC CABLE LAMP PIC. 22 ELECTRIC MOTOR VOLTAGE SUPPLY CABLE ELECTRIC CABLE PRESSURE SWITCH SAFETY EDGE WITH PRESSURE SWITCH NEVER CUT THE ELECTRIC CABLES - It is most important that the electric cables are removed from their terminals by loosening the fastening screws. Never cut the electric cables. Also make sure that the 230 V mains switch is off before removing the cables. See page 11 pic Only by keeping to these fitting instructions a reliable installation and correct performance of the equipment can be achieved. The installation is fully under the responsibility of the installation agent, even if only Fadini products have been used as indicated in this booklet. It is advisable that the system is installed in full compliance with these instructions and in observance of the existing laws for automatic gate equipment. - The information, specifications and drawings contained herein are subject to any change that the manufacturer considers as needed. 14

15 OIL-HYDRAULIC OPERATOR FOR GARAGE DOORS WITH COUNTERWEIGHTS APROLI 480 TECHNICAL SPECIFICATIONS APROLI FIXING BRACKET M DOOR OPERATOR LINEAR DESIGN APROLI 480 ELECTRIC TERMINAL OUTPUT 4 LAMP AND LAMP REFLECTOR 5 PROTECTION COVER 6 LIGHT DIFFUSION TOP COVER 7 BOTTOM COVER 91 C A APROLI 480 s.n.c. Via Mantova, 177/A Cerea (VR) Italy - Tel r.a. - Fax MOTOR W (absor.) VOLTS Rev/min. Nm 2 PHASE HP (to use) A Hz µf Protection Standards IP 55 Max. working pressure 4 MPa (40 Bar) OIL FADINI A15 BY AGIP MADE IN ITALY DATA STICKER ELECTRIC MOTOR x PIC. 23 OIL-HYDRAULIC PUMP Pump flow rate l/min. Working pressure...2 MPa (20 bar) Maximum pressure...4 MPa (40 bar) Working temperature C +80 C Opening time...18 s Recommended door size...7 m 2 Shaft rotation...max. 205 Hydraulic oil...oil Fadini A15 by Agip Static weight of operator Kg Weight of Aproli 480 with accessories...24 Kg Max. torque Nm Max. gate weight Kg ELECTRIC MOTOR Power output KW (0.33 HP) Supply voltage V Frequency...50 Hz Absorbed power W Absorbed current A Capacitor µf Motor revolution r.p.m. IP Protection Standard...IP 55 Motor rated torque Nm Lamp V - 25 W Intermittent service...s 3 PERFORMANCE Duty cycle...18 sec. Opening 30 sec. Dwell 18 sec. Closing Time of one complete cycle...66 sec. Complete cycles...no. 47/hour Annual cycles - 8 hours service per day...no

16 CHECKING AND MAINTENANCE: To achieve an optimum performance and longer life of the equipment and in observance of the safety regulations, it is recommended that inspections and proper maintenance are made by qualified technicians to the whole installation ie, both the mechanical and electronic parts, as well as wiring: - Mechanical parts: maintenance every 6 months approx. - Eletronic apparatus and safety equipment: maintenance every month. IMPORTANT WARNING NOTES - Before installing the equipment carry out a Risk Analysis and fit any required device in compliance with EN and EN Safety Norms. - It is recommended to keep to the instructions here outlined. Check the specifications on the motor sticker with your mains supply. - Dispose properly of the packaging: cardboard, nylon, polystyrene, through specializing companies. - Should the operator be removed, do not cut the electric cable. This must be properly removed from the terminal board in the junction box. - Switch off the mains switch before removing the junction box cover where the electric cable is terminated. - All the system must be earthed by using the yellow/green wire, marked by its specific symbol. - It is recommended to read the regulations, suggestions and remarks quoted in the booklet Safety Norms. Made in Italy The growth of MECCANICA FADINI has always been based on the development of guaranteed products thanks to our TOTAL QUALITY CONTROL system which ensures constant quality standards, updated knowledge of the European Standards and compliance with their requirements, in view of an ever increasing process of improvement. The CE mark certifies that the operator conforms to the essential requirements of the European Directive art. 10 EEC 73/23, in relation to the manufacturer s declaration for the supplied items, in compliance with the body of the regulations ISO 9000= UNI EN Automation in conformity to EN 12453, EN safety standards. EUROPEAN MARK CERTIFYING CONFORMITY TO THE ESSENTIAL REQUIREMENTS OF THE STANDARDS 98/37/EC DECLARATION OF CONFORMITY SAFETY NORMS EN 12453, EN STANDARDS CEI EN STANDARDS WARRANTY CERTIFICATE ON THE CUSTOMER S REQUEST AUTOMATIC GATE MANUFACTURERS s.n.c. Distributor s box The manufacturers reserve the right to change the products without any previous notice and are not liable for possible damages to people and properties. Via Mantova, 177/A Cerea (Verona) Italy - Tel r.a. - Fax info@fadini.net -

INSTALLATION MANUAL GB

INSTALLATION MANUAL GB GB INSTALLATION MANUAL @GB; 66 FITTING INSTRUCTIONS Important: Keep to the instructions outlined in the pages and diagrams that follow to achieve a perfect installation. NUPI 66 is an oil-hydraulic actuator

More information

Oil-hydraulic operator for swinging gates

Oil-hydraulic operator for swinging gates COMBI 740 Oil-hydraulic operator for swinging gates Below ground Version with two-way locking device Version with brake in open/close cycles Version with 110 and 175 shaft rotation Instruction manual GB

More information

TECHNICAL DATA HYDRAULIC UNIT

TECHNICAL DATA HYDRAULIC UNIT GB INSTRUCTIONS MANUAL RISING BOLLARD OIL-HYDRAULIC AUTOMATION COMPONENTS strabuc 918 RELEASE KEY PLUG FOR RELEASE HOLE BOLLARD COVER 12 V WARNING LIGHTS REFLECTORS COMPLETELY RETRACTABLE POST WITH ELECTROPHORESIS

More information

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional - Oleodinamica BAYT 980 Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL POLO 44 - optional - BAYT 980 560 code 4425 Post with fixing base the gate opener Made in Italy INSTALLATION MANUAL GB INSTRUCTIONS

More information

INSPECTIONS AND MAINTENANCE

INSPECTIONS AND MAINTENANCE GB INSTRUCTIONS MANUAL STRABUC 930 ARMOURED OIL-HYDRAULIC RISING BOLLARD COMPONENTS strabuc 930 RELEASE KEY PROTECTION PLUG TO ACCESS RELEASE HOLE BOLLARD COVER 12V WARNING LIGHTS REFLECTORS RISING POST

More information

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual NYOTA 115 Electro-mechanical sliding gate operator Instruction manual GB INSTRUCTIONS FOR THE INSTALLATION OF THE AUTOMATION NYOTA 115 FOR A CORRECT INSTALLATION AND GOOD PERFORMANCE OF NYOTA 115 READ

More information

GB INSTALLATION MANUAL

GB INSTALLATION MANUAL GB INSTALLATION MANUAL MEC 800 SPECIAL OIL-HYDRAULIC OPERATOR FOR SWINGING GATES. EXTERNAL APPLICATION. ESSENTIAL COMPONENTS TO FIT THE OPERATOR TO A GATE LEAF FIXING BOLT FLEXIBLE TUBE 0.5 meter STRAIGHT

More information

DRIVE 700 OVERALL DIMENSIONS

DRIVE 700 OVERALL DIMENSIONS GB INSTALLATION MANUAL DRIVE 700 INSTRUCTIONS TO INSTALL THE SYSTEM FOR A PERFECT APPLICATION AND PERFORMANCE OF DRIVE 700 SYSTEM IT IS RECOMMENDED TO KEEP TO THE INSTRUCTIONS AND THE DIAGRAMS IN THIS

More information

Instructions manual. Below ground oil-hydraulic operator for swinging gates. pages 17-32

Instructions manual. Below ground oil-hydraulic operator for swinging gates. pages 17-32 Below ground oil-hydraulic operator for swinging gates STANDARD VERSION: 110 or 17 Leaf Rotation Compact, internal drive unit and hydraulic jack Normal version or version with two-way Locking device Models

More information

BAYT 980. Oil-hydraulic Road Traffic Barrier. BAYT 980 painted version BAYT 980 stainless steel version inox

BAYT 980. Oil-hydraulic Road Traffic Barrier. BAYT 980 painted version BAYT 980 stainless steel version inox BAYT 980 Oil-hydraulic Road Traffic Barrier BAYT 980 painted version BAYT 980 stainless steel version inox GB Oil-hydraulic road traffic barrier BAYT 980 The Bayt 980 operator is a road barrier used to

More information

GB Instructions Manual

GB Instructions Manual GB Instructions Manual pages - 8 CMYK- 0 0 KYMC- 0 0 KYMC- 0 0 0 KYMC- 8 KYMC- 0 KYMC- 0 0 0 KYMC- 0 0 0 0 Underground oil-hydraulic operator for swinging gates or 7 shaft rotation Compact all-in-one oil-hydraulic

More information

1-24. Oil-hydraulic. Oil-hydraulic road barrier for traffic control from 3 to 8 metres

1-24. Oil-hydraulic. Oil-hydraulic road barrier for traffic control from 3 to 8 metres GB Instructions manual pages 1-24 Oil-hydraulic Oil-hydraulic road barrier for traffic control from 3 to 8 metres Stainless steel and painted versions Version with aluminium fence Version with articulated

More information

I - Libretto di istruzioni GB - Instructions manual F - Notices de montage

I - Libretto di istruzioni GB - Instructions manual F - Notices de montage I - Libretto di istruzioni GB - Instructions manual F - Notices de montage GB Instructions manual pages 1-20 BOLLARD WITH RETRACTABLE CYLINDRICAL POST OIL-HYDRAULICALLY OPERATED the gate opener made in

More information

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES E5 D811007 15-09-99 Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES 122 This product complies with recognised technical standards and safety regulations. We declare that this product is in conformity

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the 770

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION 770 EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the

More information

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR Installation Manual MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR 02_2016 1. WARNINGS AND GENERAL SAFETY INSTUCTIONS This manual contains important safety information. An incorrect installation or an improper

More information

a p prove d ELECTROMECHANICAL SLIDING GATE OPENER

a p prove d ELECTROMECHANICAL SLIDING GATE OPENER EN 25 EN 25 ELETROMEHNIL SLIING GTE OPENER G The Junior gear box is built completely of die cast aluminium, and the coupling is supported by shielded roller bearings. ll of the internal operational components

More information

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2. PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL Flashing Light Push Button Control box Gate 2 Gate 1 Declaration of Conformity Applicant: Powertech Electronics Inc. Manufacturer:

More information

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL Flashing Light Push Button Control box Declaration of Conformity Applicant: Powertech Electronics Inc. Manufacturer: Timotion

More information

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR Installation manual English mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR 1. WARNINGS AND GENERAL SAFETY INSTRUCTIONS This manual contains important safety information. An incorrect installation or an

More information

SWING GATE OPENERS 24V DC GEAR MOTOR

SWING GATE OPENERS 24V DC GEAR MOTOR SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL USER MANUAL Flashing Light Push Button Control box Gate 2 Gate 1 Index 1. Warnings 2 4. Technical Characteristics 16 2. Product Description 2.1 Applications

More information

E R A I GATE AUTOMATION DIVISION

E R A I GATE AUTOMATION DIVISION S E R A I GATE AUTOMATION DIVISION INSTALLATION MANUAL MC/5C - 03.5C UNDERGROUND MOTOR 230 Vac FOR WING GATES UP TO 3,00m AND 300 Kg EACH WING + FOUNDATION BOX IN HOT-GALVANISED STEEL Thank you for choosing

More information

Automation Swing Gate Opener

Automation Swing Gate Opener Automation Swing Gate Opener Operating and installation instructions SP EIFFEL 400 V1.0 Rev 08/01 CONTENTS 0) GENERAL SAFETY REGULATIONS...Page 0 1) DESCRIPTION...Page 03 ) TECHNICAL SPECIFICATIONS 3)

More information

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

SARGON S - M - L. All rights reserved INSTALLATION MANUAL INSTALLATION MANUAL Our compliments for your excellent choice. SARGON LINE S (300mm) M (400mm) and L (600mm) electro-mechanical gear motor has been produced for reliability and high quality. This Manual

More information

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy INSTALLATION MANUAL FOR SWING SHUTTERS KAF212 FACE S.r.l. Viale delle Industrie, 74 31030 Dosson di Casier Treviso Italy INDEX Subject Page 1. General safety instruction 2 1.1 EC marking and European directives

More information

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m V200 USER MANUAL SWING GATE OPENER 100kg 1.m 100kg 1.m Content Important Safety Advice... Content of the Kit... Connection Diagram... Installation Guide... Actuator... Control box... AC cable wiring...

More information

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16 Installation manual ASTER AUTOMATION FOR SWING GATES 11_16 Contents 1. GENERAL SAFETY PRECAUTIONS... page 01 2. INTENDED USE AND APPLICATION... page 01 2.1 Kit contents... page 01 2.2 Technical features...

More information

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION

More information

FITTING AND CONNECTION INSTRUCTIONS

FITTING AND CONNECTION INSTRUCTIONS LEPUS is an oil-bathed motor-reducer created for sliding gates automation. The motor-reducer irreversibility allows a perfect and safe gate closing avoiding the setup of an electrolock and in case of power

More information

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF: CAME UNITED KINGDOM LTD UNIT 3 ORCHARD PARK INDUSTRIAL ESTATE, TOWN STREET, SANDIACRE, NOTTINGHAM NG10 5BP TEL: 0115 921 0430 FAX: 0115 921 0431 TECHNICAL HELPLINE 0115 921 0430 INTERNET - www.cameuk.com

More information

BARRY BARRIER GATE AUTOMATION

BARRY BARRIER GATE AUTOMATION BARRY BARRIER GATE AUTOMATION Installation Manual 1. WARNINGS AND GENERAL SAFETY INSTUCTIONS This manual contains important safety information. An incorrect installation or an improper use may cause serious

More information

HATO 120 / 200 SECTIONAL DOOR OPERATOR USER S MANUAL HATO 120/200 SECTIONAL DOOR OPERATOR USER S MANUAL

HATO 120 / 200 SECTIONAL DOOR OPERATOR USER S MANUAL HATO 120/200 SECTIONAL DOOR OPERATOR USER S MANUAL HATO 120/200 SECTIONAL DOOR OPERATOR USER S 2 OUTLINE 1. Safety instructions...4 2. Description and features... 4 3. Technical specifications... 4 4. Check... 5 5. Installation and adjustment... 5 6. Programming...

More information

contents Installation Maintenance DOOR OPERATOR SLIDING-1300/2100 Installation and Operating Manual DoorHan, 2012

contents Installation Maintenance DOOR OPERATOR SLIDING-1300/2100 Installation and Operating Manual DoorHan, 2012 DOOR OPERATOR contents general information SAFETY INSTRUCTIONS operator unit Installation Electrical Connections Programming of Remote Controls Release Operation Maintenance Troubleshooting Warranty Card

More information

FEATURES AND SPECIFICATIONS

FEATURES AND SPECIFICATIONS FEATURES AND SPECIFICATIONS The is a high quality hydraulic operator for residential and condominium use with leaf length up to 3 m. Available in the following versions: AC (with lock in opening and closing)

More information

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack UNDERGROUND OPERATOR FOR SWINGING GATES COMPAS 2 WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack Our products if installed by qualified personnel capable to

More information

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

F ERNI K I T THE FERNI-S KIT CONSISTS OF: CAME UNITED KINGDOM LTD ORCHARD PARK INDUSTRIAL ESTATE TOWN STREET, SANDIACRE, NOTTINGHAM, NG10 5BP TEL: 0115 921 0430 FAX: 0115 921 0431 INTERNET - www.cameuk.com E-MAIL - enquiries@cameuk.com TECHNICAL

More information

Nuova CEVA Automation. Via G.B. Signini 43. Briga Novarese (NO) ITALY Tel Fax

Nuova CEVA Automation. Via G.B. Signini 43. Briga Novarese (NO) ITALY Tel Fax General Features The rotary limit switch is a device which allows you to control the movement of industrial and building machines. The shaft is connected to the motor, so that, after a certain number of

More information

BISON 20 OM BISON 25 OTI

BISON 20 OM BISON 25 OTI L8542939 11/2011 rev 0 BISON 20 OM BISON 25 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 2 x 1,5 GND 13 8 7 5 RG 58 4 3 4 x 0,35 6 1 2 4 3 x 1,5 min 230V 2 x 0,35

More information

ARACHNE 230V 24V- 12V

ARACHNE 230V 24V- 12V SWING GATES OPERATOR SERIE ARACHNE 12V-24V-220V INSTRUCTIONS MANUAL SAFETY Our compliments for your excellent choice. Your new electromechanical gear motor has been produced according to a high quality

More information

Installing the gate post bracket with the cardboard arm template

Installing the gate post bracket with the cardboard arm template ......... Installing the gate post bracket with the cardboard arm template... Installing gate posts brackets and arms for Push-to-Open or Pull-to-Open gates... Connection of Power Source 240Vac or Solar...

More information

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) Manufacturer: Address: Declares that: FAAC S.p.A. Via Benini, 1-40069 Zola Predosa BOLOGNA - ITALY 740-24V mod. operator is built to be integrated

More information

VIS IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev /2011 RT

VIS IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev /2011 RT VIS GB IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev. 01-07/2011 RT TECHNICAL DATA LIFE home integration reserves the right to change the specifications at any time without notice, maintaining

More information

Typical Installation Schematic

Typical Installation Schematic The 760 Gate Automation System The FAAC 760 automation system consists of a monoblock hydraulic unit and foundation box assembly. The system is designed for underground installation, and will not alter

More information

BULL 424 ESA BULL 624 ESA

BULL 424 ESA BULL 624 ESA L8542677 01/2012 rev 1 BULL 424 ESA BULL 624 ESA UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 140 260 92 83 330 330 210 326 2 X BULL.P3 34 mm = = 3 3 4 P P D 102 mm

More information

Nuova CEVA Automation. Via G.B. Signini 43. Briga Novarese (NO) ITALY Tel Fax

Nuova CEVA Automation. Via G.B. Signini 43. Briga Novarese (NO) ITALY Tel Fax General Features The rotary limit switch is a device, which allows you to control the movement of industrial and building machines. The shaft is connected to the motor, so that, after a certain number

More information

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS VH IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack Our products if installed by qualified personnel capable

More information

Installing the gate post bracket with the cardboard arm template

Installing the gate post bracket with the cardboard arm template ......... Installing the gate post bracket with the cardboard arm template... Installing gate posts brackets and arms for Push-to-Open or Pull-to-Open gates... Connection of Power Source 240Vac or Solar...

More information

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S L8542676 04/2012 rev. 2 BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 140 260 100 91 330 330 210 326

More information

TITANO 400V SLIDING GATE OPENER

TITANO 400V SLIDING GATE OPENER TITANO 400V SLIDING GATE OPENER USE AND MAINTENANCE MANUAL V07 /2018 TECHNICAL FEATURES א א א א QK-T3000 QK-T4000 QK-T6000 (VAC) 400 Three Phase א א א א (W) 700 750 1500 א א א א (A) 1,7 2,2 3,7 א א C -30/+70

More information

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI L8542965 03/2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 470 327 F A 500 825 B 243.5 2 C 445 210 15 ±5 205 92 50 2 3 4 I D2 D2 D1 5 T 6 D A

More information

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10 Contents EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10 WARNINGS FOR THE INSTALLER... p. 10 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS... p. 11 1.1. DIMENSIONS... p. 11 2. ELECTRIC DEVICES (standard

More information

IMPORTANT NOTICE FOR THE INSTALLER

IMPORTANT NOTICE FOR THE INSTALLER EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the 6

More information

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI L8543019 04/2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 458 250 A F 645 477 B 195 470 270 2 C 13 ±5 156 70 2 3 4 D2 R D2 I D1 T 5 W D H G R

More information

Automatic concealed bollards 275 H600 and 275 H800 Control station

Automatic concealed bollards 275 H600 and 275 H800 Control station Automatic concealed bollards 275 H600 and 275 H800 Control station Technical installation manual CE Declaration Warnings for the installer Bollard electrical connection Technical specifications for control

More information

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI L8542968 07/2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI 1 458 250 A F 645 477 B 195 470 270 2 C 13 ±5 156 70 2 3 4 D2 R D2 I D1 T 5 W D H G R

More information

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel: Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation

More information

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions 3581050/5 IM-P358-05 CH Issue 5 EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions 1 Safety information 2 General 3 Installation 4 Commissioning 5 Maintenance IM-P358-05

More information

Installation Manual. Swing Gate System. Leading the way...

Installation Manual. Swing Gate System. Leading the way... Installation Manual 402 Swing Gate System Leading the way... Contents EC DECLARATION OF CONFORMITY FOR MACHINES... p. 2 WARNINGS FOR THE INSTALLER... p. 2 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS...

More information

Single or Double 240VAC motor control for domestic and industrial gates and doors.

Single or Double 240VAC motor control for domestic and industrial gates and doors. COBO30 Double 240V Motor Drive Controller Features For 240Volt Motors Auto Closing Open Only Security Closing and Extended Lock Pulse (user selectable) Travel Timer Push Button Input Photo Cell Input Option

More information

SWING GATE OPENERS 24V DC GEAR MOTOR

SWING GATE OPENERS 24V DC GEAR MOTOR SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL USER MANUAL Flashing Light Push Button Control box Gate 2 Gate 1 Index Warnings 2 5. Technical Characteristics 21 1. Product Description and Applications

More information

USE AND MAINTENANCE MANUAL

USE AND MAINTENANCE MANUAL LATERAL TURNOVER 360 ORIGINAL INSTRUCTIONS INTRODUCTION This manual includes instructions for assembly, maintenance (regular and extraordinary), and for possible faults with remedies. The instructions

More information

LIFTMASTER MAGIC BUTTON FS10 & LPK5 FAST SLIDER

LIFTMASTER MAGIC BUTTON FS10 & LPK5 FAST SLIDER R MAGIC BUTTON FS0 & LPK5 FAST SLIDER OPERATORS MANUAL FEATURES High speed -800mm/second Corrosion resistant - Hot dip galvanised base with stainless steel cover Speed flexibility - Slow start / slow stop

More information

access

access 184 Table of Contents Access Garage door Motors Dexxo Pro 800 RTS... 188 Dexxo Pro 1000 RTS... 189 Dexxo Optimo RTS... 190 Receiver Axroll NS... 191 Freeroll ESE RTS, RTS receiver for roller garage doors...

More information

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information. Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount

More information

Sectional And Tilting Door Opener

Sectional And Tilting Door Opener Sectional And Tilting Door Opener Installation Instructions and User Guide FS 600 FS 1000 FS 1200 600N 1000N 1200N FS 600-Speed FS 1000-Speed 600N 1000N S/N WARNING Please read the manual carefully before

More information

SCUTI INSTALLATION INSTRUCTIONS FOR AUTOMATING COUNTER BALANCED DOORS USING THE SCUTI OPERATOR

SCUTI INSTALLATION INSTRUCTIONS FOR AUTOMATING COUNTER BALANCED DOORS USING THE SCUTI OPERATOR INSTALLATION SCUTI INSTALLATION INSTRUCTIONS FOR AUTOMATING COUNTER BALANCED DOORS USING THE SCUTI OPERATOR GENERAL INFORMATION The Scuti kit consists of a self contained power mono-bloc, with installation

More information

VER KIT. Installation Instructions TECHNICAL HELPLINE

VER KIT. Installation Instructions TECHNICAL HELPLINE CAME UNITED KINGDOM LTD UNIT 3 ORCHARD PARK INDUSTRIAL ESTATE, TOWN STREET, SANDIACRE, NOTTINGHAM NG10 5BP TEL: 0115 921 0430 FAX: 0115 921 0431 TECHNICAL HELPLINE 0115 921 0430 INTERNET - www.cameuk.com

More information

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax V2 S.p.A. Corso Principi di Piemonte, 65/67 12035 RACCONIGI (CN) ITALY tel. +39 01 72 81 24 11 - fax +39 01 72 84 050 info@v2home.com - www.v2home.com IL n.131 EDIZ. 28/08/2012 Bingo I GB F E P D NL ATTUATORE

More information

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012 OPERATOR contents General Information Safety instructions Operator unit operator Installation Electrical Connections adjustment of extreme positions operator programming Release operation Maintenance Trouble

More information

Automatic concealed bollards 275 H600 and 275 H800 with pit

Automatic concealed bollards 275 H600 and 275 H800 with pit Automatic concealed bollards 275 H600 and 275 H800 with pit Technical installation manual CE Declaration of conformity Warnings for the installer Bollard technical data Preparing and installing the bollard

More information

Automations for garage doors and rolling shutters

Automations for garage doors and rolling shutters Automations for garage doors and rolling shutters Technology Versatility Low consumption BLINKO Flashing LED Technological solutions for safe operation All V2 operators for garage doors allow: - Precise

More information

HÖRMANN DSA 100 DSA 100 L DSA 200 DSA 200L. page 1

HÖRMANN DSA 100 DSA 100 L DSA 200 DSA 200L. page 1 HÖRMNN Spindle drive operator for hinged gates DS 100 DS 100 L DS 200 DS 200L Installation Instructions page 1 1 Overview of spindle drive operator for hinged gates E F a e f C b c D d g Table 1: Drive

More information

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5 REV 12a Table of Contents General Safety....... 2 Preparation for Installation....... 3 Parts List....... 4 Optional Accessories Part List...... 5 Technical Specifications & Feature...... 5 Installation

More information

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS SLIDING GATE OPENER DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS The strongest solution for sliding gates PL600/PL1000 electro-mechanical sliding gate openers are designed

More information

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017 SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. OPERATOR TECHNICAL SPECIFICATIONS DESCRIPTION DIMSIONS

More information

INSTALLATION MANUAL (cod )

INSTALLATION MANUAL (cod ) is a bollard designed for the management of traffic areas, parkings and protection of public and private accesses. It has an hydraulic system is engineered in our factory to achieve minimum noise and maximum

More information

INSTRUCTIONS FOR INSTALLATION

INSTRUCTIONS FOR INSTALLATION HYDRAULIC OPERATOR MODO 110-110/L FOR SINGLE- OR DOUBLE-WING SWING GATES INSTRUCTIONS FOR INSTALLATION GENERAL WARNINGS These warnings constitute an integral and essential part of the product and must

More information

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO Istruzioni, instructions Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO 1 Istruzioni, instructions Attention! This manual is for qualified

More information

Porte 150 Users Manual Swing Gate Opener 24V DC

Porte 150 Users Manual Swing Gate Opener 24V DC Porte 150 Users Manual Swing Gate Opener 24V DC for residential use only Signal Light Push-button Control Box 14 Contents 1. Important Safety Information 2. Product Description and Application 2.1 Application

More information

Moments. It doesn t fall because of the presence of a counter balance weight on the right-hand side. The boom is therefore balanced.

Moments. It doesn t fall because of the presence of a counter balance weight on the right-hand side. The boom is therefore balanced. Moments The crane in the image below looks unstable, as though it should topple over. There appears to be too much of the boom on the left-hand side of the tower. It doesn t fall because of the presence

More information

OPERATOR SHAFT-120. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION

OPERATOR SHAFT-120. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION OPERATOR CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION ELECTRICAL CONNECTIONS ADJUSTMENT OF EXTREME POSITIONS OPERATOR PROGRAMMING RELEASE OPERATION MAINTENANCE TROUBLE

More information

Rotary Limit Switches Driver FRS Series

Rotary Limit Switches Driver FRS Series Rotary Limit Switches Driver FRS Series TM Limit Switches Driver FRS Series Main Features Driver rotary limit switch Series FRS is a device which allows you to control the movement of industrial and building

More information

Electromechanical gear motor for sliding gates ACHILLES

Electromechanical gear motor for sliding gates ACHILLES Electromechanical gear motor for sliding gates ACHILLES 1 Attention! This manual is for qualified installers only and not for the end user. It is the installer s job to explain to the user how the automatism

More information

OPERATING AND MAINTENANCE INSTRUCTIONS HYDRAULIC ELECTRICAL PUMPS HAM (Manual control) HAE (Electrical control)

OPERATING AND MAINTENANCE INSTRUCTIONS HYDRAULIC ELECTRICAL PUMPS HAM (Manual control) HAE (Electrical control) OPERATING AND MAINTENANCE INSTRUCTIONS HYDRAULIC ELECTRICAL PUMPS HAM (Manual control) HAE (Electrical control) Part Nr : HA M 4 6 2 1 B C 1. Essential safety requirements. 2. Technical Characteristics.

More information

Rotary Limit Switches Driver FRM Series

Rotary Limit Switches Driver FRM Series Rotary Limit Switches Driver FRM Series TM Limit Switches Driver FRM Series Main Features The rotary limit switch is a device which allows you to control the movement of industrial and building machines.

More information

STAND MODEL FOR MACH M2

STAND MODEL FOR MACH M2 Mounting instructions Directions for use STAND MODEL FOR MACH M2 Stand lamps: Mach M2... Mach M2 F... Order No. 170 120 1300 Order No. 170 230 1300 GmbH u. Co. KG, Flossmannstrasse 28, D-85560 Ebersberg

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Emergency Cord Switch Type PRS Device identification No.: 91.054 033.001, /.101 and /.201 OPERATING INSTRUCTIONS 2 CE Sign and Conformity The device meets the requirements of the valid European and national

More information

TMT Boxer 24v slider motor installation notes from EasyGate

TMT Boxer 24v slider motor installation notes from EasyGate TMT Boxer 24v slider motor installation notes from EasyGate Install Physical Gate Stops Physical Gate Stops MUST be installed at each end of your gate. If the Limit Switch on the boxer motor fails to stop

More information

Assembly instructions Rev. 10/08 ENG

Assembly instructions Rev. 10/08 ENG Assembly instructions Rev. 10/08 ENG 8500 SF 24V belt driven garage door opener Kg Max traction: 70 kg max. 8 m 2 Power; 230 V / 50 Hz UK HELP-LINE: 0845 136 2012 Mo-Fri: 0900-1900 Sat: 0900-1700 Sun:1000-1600

More information

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm INSTLLTION MNUL The LPH is provided with a mechanical locking system that grants the operator locking in the opened and closed position avoiding any needs for electric locks and/or magnetic locks. The

More information

AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G G2080I

AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G G2080I AUTOMATION FOR STREET BARRIERS GARD 8 SERIES INSTALLATION MANUAL G2080 - G2080I IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION

More information

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING Sliding Gate Opener Model: DKC400Y Installation Manual WARNING Read and thoroughly understand all instructions before installing or operating this automatic gate opener. Failure to do so may cause serious

More information

SKC400U SLIDING GATE OPENER OWNER S MANUAL

SKC400U SLIDING GATE OPENER OWNER S MANUAL SKC400U SLIDING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the SKC400U Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained

More information

PY600AC Sliding Gate Opener User Manual

PY600AC Sliding Gate Opener User Manual PY600AC Sliding Gate Opener User Manual 2017 Dear users, Thank you for choosing this product. Please read the manual carefully before assembling and using it. Please do not leave out the manual if you

More information

ACROBAT SWING STAND MODEL

ACROBAT SWING STAND MODEL Mounting instructions Directions for use ACROBAT SWING STAND MODEL Stand lamps: Mach 120... Mach 120F... Mach 130... Mach 130F... Mach LED 120... Mach LED 120F... Mach LED 130... Mach LED 130F... Order

More information

INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator

INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator Serial #: Date Installed: Your Dealer: READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE. SAVE THESE INSTRUCTIONS. Introduction

More information

Type of installation. external motor. underground motor. Leaf max length (m) Leaf max length (m) Max leaf weight (kg) V V V

Type of installation. external motor. underground motor. Leaf max length (m) Leaf max length (m) Max leaf weight (kg) V V V Type of installation external motor Residential 391 24V 390 230V 390 24V 412 230V 413 230V 415 415 24V S418 402 422 422 PED. S450H Condominium 415 L 415 L 24V 422 422 PED. 400 S450H Industrial 400 Leaf

More information

Rolling Door Operator User s Manual

Rolling Door Operator User s Manual Rolling Door Operator User s Manual MODEL: RSI-500KG Rolling Steel Ind. Brooklyn NY Tel. 718 272-4444 OUTLINE 1. Important safety information 1 2. Main technical parameters 1 3. Introduction 1 4. Installation

More information

Lifting device for standard removable versions

Lifting device for standard removable versions Operating manual Lifting device for standard removable versions Type 1889 haacon hilft heben haacon hebetechnik gmbh Josef-Haamann-Str. 6 D-97896 Freudenberg/Main Tel: +49 (0) 93 75/84-0 Fax: +49 (0) 93

More information