NEBBinar: A TAB Professional s Wish List: Equipment Procedures & Issues. March 27, 2014

Size: px
Start display at page:

Download "NEBBinar: A TAB Professional s Wish List: Equipment Procedures & Issues. March 27, 2014"

Transcription

1 NEBBinar: A TAB Professional s Wish List: Equipment Procedures & Issues March 27,

2 Moderator Tom Hanlon NEBB s TAB Committee Tom has forty years of experience in refrigeration systems control system design, installation, start-up, project management, technical consultation, and systems commissioning. His level of experience allows him to act as an Owner s Representative on commissioning, retro-commissioning and sustainability projects. Has worked as an application engineer and project manager for ten years with Johnson Controls; fifteen years as an independent NEBB Testing-Balancing Commissioning Agency; six years as project manager for Trane Arkansas and recently managed multiple commissioning and sustainability projects as a contract provider for TME Inc. Tom is currently Commissioning Project Manager with the Cromwell Firm, managing and executing multiple Commissioning and Retrocommissioning projects. 1

3 Speaker Rodney Hinton NEBB s TAB Committee Rodney Hinton is the VP of Palmetto Air & Water Balance, has been involved in the South Carolina Construction industry for over 30 years. His experience includes Air Barrier Testing, Mechanical Design, Mechanical Construction, Test & Balance, Commissioning and Retro Commissioning. He is a member of the NEBB Test, Adjust and Balancing Committee. He is a Member of ASHRAE. He has been a NEBB Certified professional since 1991 and has co-authored several standards regarding TAB and BET for NEBB. 2

4 Speaker Leonard Maiani NEBB s Technical Director Leonard Maiani joined NEBB as Technical Director in January He brings over 48 years of industry experience. He began his career in the Testing, Adjusting & Balancing business in Cleveland, Ohio 1n He then spent 15 years working in Houston, Texas as a Construction Administrator and TAB professional in various organizations. In 1989, he started Maiani Construction Services in 1989 in the Pacific Northwest and, after 27 years, turned the business over to his son and joined the NEBB staff. 3

5 Agenda Overview of Testing, Adjusting and Balancing NEBB TAB Update: New Procedural Standards-Update-Release Instrument Consolidations Enhanced equipment reporting Equipment Procedures-Issues: Fan Powered VAV-Series & Parallel Energy Recovery-Heat Recovery Systems. Types, Procedures, Issues Question and Answers 4

6 Agenda Overview of Testing, Adjusting and Balancing NEBB TAB Update: New Procedural Standards-Update-Release Instrument Consolidations Enhanced equipment reporting Equipment Procedures-Issues: Fan Powered VAV-Series & Parallel Energy Recovery-Heat Recovery Systems. Types, Procedures, Issues Question and Answers 5

7 NEBB TAB Procedural Standards Update Format Change: Shall, Should, May eliminated. Now Required New Procedural Standards-Update-Release 6

8 NEBB TAB Procedural Standards (continued) The NEBB Procedural Standards for Testing Adjusting and Balancing of Environmental Systems establish a uniform and systematic set of criteria for the performance of the testing, adjusting and balancing of environmental or Heating, Ventilating and Airconditioning (HVAC) systems. Today s buildings provide highly controlled, sustainable energy efficient indoor environments. These buildings include very sophisticated mechanical systems created by a team of skilled professionals. A key member of this team is the NEBB Test, Adjust, and Balance (TAB) Certified Firm. 7

9 This Eighth Edition represents an update from past editions but remains divided into two distinct Parts: Standards and Procedures. These TAB Procedural Standards have been developed using language defined by Required as it relates to the standards and procedures described in this manual. It is important to note this wording throughout this manual and how it pertains to the NEBB standards and procedures. These standards and procedures are intended as the minimum NEBB requirements that a NEBB TAB Certified Firm must follow when performing Testing, Adjusting, and Balancing procedures. Contract documents may supersede the NEBB requirements. These TAB Procedural Standards have been carefully compiled and reviewed by the NEBB Technical Committees. 8

10 9 Instrument Requirements Changed Tuned-up

11 Enhanced Equipment Reporting-Example: Air Handling Unit (Unitary-Belt Driven) Design Data Unit designation / Area Served Unit type / arrangement / location Manufacturer Model number Total design airflow Total outlet airflow Outside airflow Fan rpm Fan motor HP (kw) Fan motor rpm Fan motor voltage Fan motor phase Total SP / External SP 10

12 11 Enhanced Equipment Reporting-Example: Air Handling Unit (Unitary-Belt Driven) Actual-Field Data Unit serial number Supply airflow Return airflow Outside airflow. Minimum, Maximum External suction SP External discharge SP External SP Fan motor manufacturer Fan motor frame Fan motor HP (kw) Fan motor rpm Fan motor operating HZ, Static Pressure Setpoint Fan motor calculated BHP (kw) Fan motor rated voltage Fan motor rated amperage Fan motor service factor Fan motor operating voltages Fan motor operating amperages Sheave manufacturer Motor sheave OD / bore Fan sheave OD / bore Adjustable sheave operating diameter Sheave centerline distance Fan rpm Belt manufacturer Number belts / size Number filters / type / size All coil and filter pressure drops ( P)

13 Agenda Overview of Testing, Adjusting and Balancing NEBB TAB Update: New Procedural Standards-Update-Release Instrument Consolidations Enhanced equipment reporting Equipment Procedures-Issues: Fan Powered VAV-Series & Parallel Energy Recovery-Heat Recovery Systems. Types, Procedures, Issues Question and Answers 12

14 Fan-Powered Terminal Units warm plenum air parallel cool primary air series 13

15 Parallel, Fan-Powered 100% heating tempering maximum primary airflow % airflow to space plenum air primary air minimum primary airflow 0% design heating load space load design cooling load 14

16 Design Data Parallel, Fan-Powered VAV terminal designation Terminal Type (Series / Parallel) Primary maximum airflow Primary minimum airflow(s) Size Fan airflow Number Filters / Size DDC address Plenum terminal mixing fan primary air supply air 15

17 Parallel, Fan-Powered Actual-Field Data Final maximum cooling airflow Final minimum cooling airflow Final primary heating airflow Fan airflow Fan speed (High, Medium, Low, Variable etc.) DDC flow correction / calibration factor(s) (where available) Include connected Grille, Register, and Diffuser data for each VAV address. Comply with 5.9 Air Outlet Test Data primary air Plenum terminal mixing fan supply air 16

18 Parallel, Fan-Powered Common Issues Issues Bad primary inlet conditions, restricted airflow - difficult DDC calibration. Remedy Specify hard duct connections, inspect installation before TAB, assist Ca & Cx. primary air Plenum terminal mixing fan Poor or no fan speed control. Difficult to set design heating airflows. Review submittals, shop drawings. Insure speed controls, speed selection methods are provided. supply air 17

19 Parallel, Fan-Powered Common Issues (continued) Issues Bad primary inlet conditions, restricted airflow - difficult DDC calibration. Poor or no fan speed control. Difficult to set design heating airflows.. Remedy Location.Location Lo cation. Review drawings, suggest terminals located in hallways, common areas. Suggest ECM motors. Quiet operation, slow ramp-up no contactor noise. Infinite adjustment. Definitive reporting. Indicate fan airflow versus DDC air flow. primary air Plenum terminal mixing fan supply air 18

20 Series, Fan-Powered 100% % airflow to space heating plenum air tempering primary air maximum primary airflow minimum primary airflow 0% design heating load space load design cooling load 19

21 Series, Fan-Powered Design Data VAV terminal designation Terminal Type (Series / Parallel) Primary maximum airflow Primary minimum airflow(s) Size Fan airflow Number Filters / Size DDC address terminal mixing fan primary air Actual-Field Data Final maximum cooling airflow Final minimum cooling airflow Final primary heating airflow Fan airflow Fan speed (High, Medium, Low, Variable etc.) DDC flow correction / calibration factor(s) (where available) Include connected Grille, Register, and Diffuser data for each VAV address. Comply with 5.9 Air Outlet Test Data plenum supply air 20

22 Series, Fan-Powered Design Data VAV terminal designation Terminal Type (Series / Parallel) Primary maximum airflow Primary minimum airflow(s) Size Fan airflow Number Filters / Size DDC address terminal mixing fan primary air Actual-Field Data Final maximum cooling airflow Final minimum cooling airflow Final primary heating airflow Fan airflow Fan speed (High, Medium, Low, Variable etc.) DDC flow correction / calibration factor(s) (where available) Include connected Grille, Register, and Diffuser data for each VAV address. Comply with 5.9 Air Outlet Test Data plenum supply air 21

23 Series, Fan-Powered Issues Bad primary inlet conditions, restricted airflow - difficult DDC calibration. Remedy Specify hard duct connections, inspect installation before TAB, assist Ca & Cx. primary air terminal mixing fan Poor or no fan speed control. Difficult to set design heating airflows. Noise.Noise. Less of an issue than parallel, still a problem!! Review submittals, shop drawings. Insure speed controls, speed selection methods are provided. plenum supply air 22

24 Series, Fan-Powered Issues Less common, requires more definitive balancing. DDC control system only reports primary air. Remedy Location.Location Location. Review drawings, suggest terminals located in hallways, common areas Suggest ECM motors. Quiet operation, slow ramp-up no contactor noise. Infinite adjustment. Fine balance required at plenum entrance to terminal. Definitive reporting. Indicate fan airflow versus DDC air flow. primary air plenum terminal mixing fan supply air 23

25 Energy Recovery Systems- Types Heat Recovery (Sensible) (Plate) Energy Recovery (Total) (Rotary Wheel) 24

26 Plate-type / Air to Air Heat Exchangers (Heat Only) Design Data Unit designation / Service Unit Location Manufacturer Model number Outside Airflow Supply Airflow Building Return/ Exhaust Airflow Unit Exhaust Airflow Plate Exchanger P (Primary & Secondary) All Filter Pressure Drops P Outside Air DB & WB Temperatures Supply Air DB & WB Temperatures Return Air DB & WB Temperatures Exhaust Air DB & WB Temperatures All Fan Data As Per Section 5.6 or

27 Plate-type / Air to Air Heat Exchangers (Heat Only) Actual-Field Data Unit serial number Outside Airflow Supply Airflow Building Return/ Exhaust Airflow Unit Exhaust Airflow Plate Exchanger P (Primary & Secondary) Outside Air DB & WB Temperatures Supply Air DB & WB Temperatures Return Air DB & WB Temperatures Exhaust Air DB & WB Temperatures All Plate and Filter Pressure Drops ( P) Number filters / Type / Size All Fan Data As Per Section 5.6 or

28 Plate-type / Air to Air Heat Exchangers Issues Limited or no access to unit for evaluation. Plugged heat exchanger passages. Burst (or breached) plate frame passages. Systems are commonly used in lab or dirty environments. Freeze-ups in the air passages!!! By-pass dampers?? Remedy Insure during prebalance inspections / site visits confirm that all testing requirements can be accomplished. Caution installing contractor to develop and maintain an aggressive filter verification program during start-up and construction phase operation. Remedy Insure caution is used during early use of units. Large differential pressures at the plates can cause rupture between airstreams..!!!! Insure that all exhaust ducts are properly sealed, properly routed and room or space relationships are as per spec. 27

29 Energy Recovery Systems- Types Heat Recovery (Sensible) (Plate) Energy Recovery (Total) (Rotary Wheel) 28

30 Wheel-type / Air to Air Exchangers (Heat or Total Exchange) Design Data Unit designation / Service Unit Location Manufacturer Model number Outside Airflow Supply Airflow Building Return/ Exhaust Airflow Unit Exhaust Airflow Transfer Wheel Purge Airflow Transfer Wheel P (Both Air Paths) All Filter Pressure Drops P Outside Air DB & WB Temperatures Supply Air DB & WB Temperatures Return Air DB & WB Temperatures Exhaust Air DB & WB Temperatures All Fan Data As Per Section 5.6 or

31 Wheel-type / Air to Air Exchangers (Heat or Total Exchange) Actual-Field Data Unit designation / Service Unit Location Manufacturer Model number Outside Airflow Supply Airflow Building Return/ Exhaust Airflow Unit Exhaust Airflow Transfer Wheel Purge Airflow Transfer Wheel P (Both Air Paths) All Filter Pressure Drops P Outside Air DB & WB Temperatures Supply Air DB & WB Temperatures Return Air DB & WB Temperatures Exhaust Air DB & WB Temperatures All Fan Data As Per Section 5.6 or

32 Wheel-type / Air to Air Exchangers (Heat or Total Exchange) 31

33 Wheel-type / Air to Air Exchangers (Heat or Total Exchange) Issues Limited or no access to unit for evaluation. Plugged and contaminated wheel surfaces. Exchange wheel deflection. Frost wheel. Bypass dampers?? Remedy Insure during pre-balance inspections / site visits confirm that all testing requirements can be accomplished. Caution installing contractor to develop and maintain an aggressive filter verification program during start-up and construction phase operation. Remedy Insure caution is used during early use of units. Large differential pressures at the wheel or using just the supply or exhaust track can cause damaging the wheel cassett..!!!! 32

34 Wheel-type / Air to Air Exchangers (Heat or Total Exchange) Issues Insure wheel seals are properly adjust by approved factory start-up. Insure purge air correct purge air settings are made prior to balancing. Conduct temperature and static pressure profiles after all airflow adjustments are successfully completed. Remedy Leaking or not properly adjusted seals will cause air transfer within the unit, resulting in less than desired airflow. Lack of purge air adjustments will cause excessive air transfer within the unit, resulting in less than desired airflow. Seals 33

35 Summary: State of Our Industry NEBB s updated Procedural Standards are a reflection of the more complex and demanding HVAC systems. Training and testing of our TAB Professionals and Technicians is increasing in intensity, frequency and rigor. NEBB is working tirelessly in our expanding sustainable environments to insure energy conservation and healthy indoor environments. Future topics..hydronic Systems 34

36 Contact Information Tom Hanlon, NEBB s TAB Committee Telephone: thanlon@cromwell.com Rodney Hinton, NEBB s TAB Committee Telephone: rhinton@palmettoairbalance.com Leonard Maiani, NEBB s Technical Director Telephone: leonard@nebb.org. 35

37 Thank you for joining the webcast. To improve future NEBBinars, please take a minute to answer a brief survey that will be sent to you. 36

38 NEBB. All rights reserved.

VAV AIRFLOW CONTROL. Reliable Without Limitations? Ron Simens, Facility Dynamics Engineering. 21 st National Conference on Building Commissioning

VAV AIRFLOW CONTROL. Reliable Without Limitations? Ron Simens, Facility Dynamics Engineering. 21 st National Conference on Building Commissioning Reliable Without Limitations? Ron Simens, Facility Dynamics Engineering 21 st National Conference on Building Commissioning AIA Quality Assurance The Building Commissioning Association is a Registered

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3042 on exhaust and ventilation with specific criteria for projects involving design of Laboratory Exhaust and Systems.

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

Demand Based Static Pressure Reset Control for Laboratories

Demand Based Static Pressure Reset Control for Laboratories Accutrol, LLC Product Sheet Demand Based Static Pressure Reset Control for Laboratories Accutrol, LLC 21 Commerce Drive, Danbury, CT 06810 203-445-9991 www.accutrolllc.com Contents and specifications are

More information

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4

More information

BALANCE REPORT DSF#: 06A3T

BALANCE REPORT DSF#: 06A3T 0B E. Grand Ave. Eau Claire, WI 570 Eau Claire: (75) 835-783 Madison: (608) 5-6 FAX: (75) 73-59 Email: tbservicesltd@charter.net Testing & Balancing System Analysis Air Hydronics Sound Vibration BALANCE

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

Element D Services Heating Ventilating and Air Conditioning ODG010107

Element D Services Heating Ventilating and Air Conditioning ODG010107 Element D Services Heating Ventilating and Air Conditioning ODG010107 D304203 Vivarium Exhaust and Ventilation System Part 1. General 1. This section supplements Design Guideline Element D3042 on exhaust

More information

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician: START-UP INSTRUCTION OPTIMUM 36000 To 72000 BTU S PACKAGE UNITS 3 To 6 Ton START-UP CHECKLIST Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD R CONTENTS MODEL: KYODO / KYODO-R... 1 INTRODUCTION... 1 APPLICATION... 1 VARIABLE AIR VOLUME SYSTEM... 1 FEATURES... 2 MATERIALS... 3 AIR VOLUME CONTROL

More information

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404) 500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage

More information

WAC Air Curtains Technical Guide

WAC Air Curtains Technical Guide TGWAC-2 WAC Air Curtains Technical Guide FOR WIND STOPPING, INSECT CONTROL, AND ENVIRONMENTAL SEPARATION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS TABLE OF CONTENTS Introduction......................................................................2

More information

Commissioning chilled water TES systems

Commissioning chilled water TES systems Commissioning chilled water TES systems Chilled water thermal energy storage systems should be as simple as possible. The success of a project depends on documenting and continually evaluating the owner

More information

ENERGY STAR Certified Homes Clearing the Air: Ventilation. March 2, 2016

ENERGY STAR Certified Homes Clearing the Air: Ventilation. March 2, 2016 ENERGY STAR Certified Homes Clearing the Air: Ventilation March 2, 2016 Agenda Value and components of ventilation & indoor air quality Live demo of RESNET-approved tools Best practices for Raters Question

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MiniCOREVentilator ENERGY RECOVERY CORE INSTALLATION INSTRUCTIONS MC500-1ERV JANUARY 10, 2018 SUPERSEDES: NONE INSTALLATION INSTRUCTIONS FOR MINICORE VENTILATOR (MCV) WITH FACTORY INSTALLED OPTIONS USED

More information

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician: START-UP INSTRUCTION START-UP CHECKLIST SERIES 5 36000 To 72000 BTU S PACKAGE UNITS 3 To 6 Ton Date: _ Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up

More information

FOR USE IN SOLUTION AIR HANDLING UNITS

FOR USE IN SOLUTION AIR HANDLING UNITS AMS-60 AIRFLOW MONITORING DEVICE APPLICATION GUIDE Supersedes: NOTHING Form 102.20-AG1 (303) FOR USE IN SOLUTION AIR HANDLING UNITS GENERAL The YORK AMS-60 is an airflow monitoring device which combines

More information

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone. INSTALLATION & OPERATION MANUAL Fan Powered Terminals VAV TERMINALS IOM FAN POWERED TERMINALS Receiving Inspection After unpacking the terminal, check it for shipping damage. If any shipping damage is

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

Element D Services Heating Ventilating and Air Conditioning ODG010107

Element D Services Heating Ventilating and Air Conditioning ODG010107 Element D Services Heating Ventilating and Air Conditioning ODG010107 D304202 Laboratory Exhaust and Ventilation Part 1. General 1. This section supplements Design Guideline Element D3042 on air handling

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -HS, Vektor -MS and Vektor -CS with Variable Geometry Nozzle September 017 Vektor -HS, Vektor -MS and Vektor -CS Greenheck s Variable Geometry Nozzle exhaust systems allow

More information

Air Handling Unit Construction Checklist

Air Handling Unit Construction Checklist Air Handling Unit Construction Checklist Project: Date: AHU Tag: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing.

More information

Sound Application Guide: Description and Ratings

Sound Application Guide: Description and Ratings Sound Application Guide: Description and Ratings AHRI SOUND STANDARD: DESCRIPTION AND RATINGS Table of Contents Overview..........................................................................4 AHRI

More information

Low Rigor ISP Study Summary Fan Coil Unit EC Motors

Low Rigor ISP Study Summary Fan Coil Unit EC Motors Low Rigor ISP Study Summary Fan Coil Unit EC Motors ISP Study Target Application: Fan Coil Unit Motors for Systems Designed from 2012 through 2014 ISP Report Finalization Date: 08/03/2017 1 RESEARCH SUMMARY

More information

Need a. Bathroom Fan?

Need a. Bathroom Fan? Need a Bathroom Fan? ASX CEILING FANS Features ASX VCDD and VCDK Ceiling Ventilators have been designed to give quality conscious architects, design engineers, builders and specifiers the ultimate in heavy

More information

Performance Rating of Airto-Air Heat Exchangers for Energy Recovery Ventilation Equipment

Performance Rating of Airto-Air Heat Exchangers for Energy Recovery Ventilation Equipment AHRI Standard 1060 (I-P) 2011 Standard for Performance Rating of Airto-Air Heat Exchangers for Energy Recovery Ventilation Equipment IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does

More information

Central Station Air-Handling Units

Central Station Air-Handling Units 2008 STANDARD FOR Standard 430 Central Station Air-Handling Units ISHRAE ( INDIAN SOCIETY OF HEATING, REFRIGERATING & AIR CONDITIONING ENGINEERS 4100 N. FAIRFAX DR., STE. 200 ARLINGTON, VIRGINIA 22203

More information

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser The ZC 107 Zone Control System was designed to provide the perfect comfort control within the home. At the same time it was designed to make an airconditioning system work more efficiently and thereby

More information

Johnson Controls Rooftop Units

Johnson Controls Rooftop Units Johnson Controls Rooftop Units NexusPremier 25-50 Tons NexusPremier Rooftops: 25-50 Tons Unmatched Efficiency NexusPremier commercial rooftop units from Johnson Controls offer class-leading standard efficiency

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning Laboratory Exhaust and PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3042 on exhaust and ventilation with additional criteria for projects involving design of laboratory

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

FDCLP2 Constant Volume Series Flow, Low Profile

FDCLP2 Constant Volume Series Flow, Low Profile The Price low profile series fan powered terminal unit is an ideal product for use in typical series fan powered applications with limited ceiling space. The is designed for constant air volume applications,

More information

Variable Air Volume Distribution Units CII, September 1 st, Home

Variable Air Volume Distribution Units CII, September 1 st, Home Variable Air Volume Distribution Units CII, September 1 st, 2010 1 VAV It s All About Measuring Airflow Accurate air flow measurement allows you to: Provide the absolute minimum air flow needed for ventilation.

More information

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION P R O D U C T S P E C I F I C AT I O N S I N D O O R A I R Q U A L I T Y ERV ENERGY RECOVERY VENTILATOR 60 HZ Bulletin No. 20245 March 200 Supersedes April 2009 Indoor / Outdoor 500 to 0,000 cfm Capacity

More information

SINGLE DUCT AIR TERMINAL UNITS

SINGLE DUCT AIR TERMINAL UNITS SINGLE DUCT AIR terminal units SINGLE DUCT AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units

More information

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15, 20 & 25 TONS MODELS: J07 thru 25NC, 2-PIPE J10 thru 20ND, 4-PIPE

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15, 20 & 25 TONS MODELS: J07 thru 25NC, 2-PIPE J10 thru 20ND, 4-PIPE SUBMITTAL DATA SHEET SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15, 20 & 25 TONS MODELS: J07 thru 25NC, 2-PIPE J10 thru 20ND, 4-PIPE JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR:

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

Air Measuring Products AMD AMS IAQ

Air Measuring Products AMD AMS IAQ Air Measuring Products AMD AMS IAQ January 1 2012 Air Measuring Products Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. By measuring the

More information

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016 Modular Air Handling U n i t R a n g e Up to 3,500 Litres / sec Low profile & Plant room application AirDesign 2015 AirDesign 2016 Second Edition Draft Version A-. Air Design is a proud Australian based

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

Greater Cleveland Regional Transit Authority

Greater Cleveland Regional Transit Authority Greater Cleveland Regional Transit Authority Summary of Proposed Award Vanpool Program Presented to: Operations Committee August 2, 2016 What is a Vanpool? A vanpool is a group of people (larger than 5)

More information

TSS Single-Duct VAV Terminals

TSS Single-Duct VAV Terminals TSS Single-Duct VAV Terminals Model TSS construction features Standard Construction Mechanical-lock construction ensures lowest possible casing leakage Roll-formed inlet collar with integral stiffening

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

ENERGY RECOVERY SYSTEM 60 HZ

ENERGY RECOVERY SYSTEM 60 HZ I N D O O R A I R Q U A L I T Y E N G I N E E R I N G D A T A ENERGY RECOVERY SYSTEM 60 HZ Bulletin No. 210517 April 2008 Supersedes 210368 April 2007 300 to 6200 cfm Capacity MODEL NUMBER IDENTIFICATION

More information

PRODUCT ANNOUNCEMENT. There is a better way to measure air flow. The New Fluke 922 Airflow Meter

PRODUCT ANNOUNCEMENT. There is a better way to measure air flow. The New Fluke 922 Airflow Meter PRODUCT ANNOUNCEMENT There is a better way to measure air flow The New Fluke 922 Airflow Meter Fluke announces the new 922 Airflow Meter, making airflow measurements easy by combining three tools: differential

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

Rosemex Products 96 VENTILATION INDUCTION UNIT

Rosemex Products 96 VENTILATION INDUCTION UNIT 10 Rosemex Products 96 VENTILATION INDUCTION UNIT 1 INDEX Unit features... 1-4 Nomenclature... 5 System comments... 5 Selection procedures... 5-6 Vertical selection tables... 7-12 Low Vertical selection

More information

NEBB STANDARDS SECTION-6, PART 2 PROCEDURES

NEBB STANDARDS SECTION-6, PART 2 PROCEDURES NEBB STANDARDS SECTION-6, PART 2 PROCEDURES SECTION 6 BASIC TAB MEASUREMENTS 6.1 INTRODUCTION The purpose of this Section is to describe the procedures used in making basic TAB measurements. These recommended

More information

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI Air Terminal Units Models MQTH, MQFCI and MQFVI Catalog 903-1 Model MQTH Model MQFCI Model MQFVI Table of Contents Single Duct Air Terminal Units.... 3 Introduction....3 MQTH-500 Single Duct Air Terminal

More information

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GN Series Single Packaged Gas/Electric Units with R-410A R6GN 10.8 EER Commercial System 12½ and 15 Ton Units These units offer flexibility in the replacement market. The 12½

More information

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume PennBarry Fan Guide Specification Laboratory Exhaust System: Model vplume This document 2018 PennBarry vplume is a commercial lab exhaust fan that ensures a greater margin of safety by effectively dispersing

More information

SDL Single-Duct, Low-Height, VAV Terminals

SDL Single-Duct, Low-Height, VAV Terminals SDL -Duct, Low-Height, VAV Terminals SDL -Duct, VAV Terminals: Fit more comfort in less space Owners SDL terminals offer the typical benefits provided by single-duct units, while performing at extremely

More information

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 Product Data FMA4X, FMA4P APARTMENT FAN COIL UNIT 1 1/2 TONS THROUGH 3 TONS APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits

More information

Energy Performance Information Request Timeline

Energy Performance Information Request Timeline Energy Performance Information Request Timeline Project Title: UT Project # Project Manager: Submitted by: Day Submitted: The timeline below outlines a comprehensive list of required documents and when

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

Division Project No. 10L2G

Division Project No. 10L2G LINCOLN HILLS SCHOOL HVAC STUDY DEPARTMENT OF CORRECTIONS MERRILL, WISCONSIN Division Project No. 10L2G April 29, 2011 By RAASCH ASSOCIATES, INC. 400 AMS COURT GREEN BAY, WISCONSIN 54313 920-434-2128 Page

More information

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES FFMA BASE SERIES FAN COIL SIZES 018 TO 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split- system

More information

Factory Option Codes L M E S P R D V F F H E

Factory Option Codes L M E S P R D V F F H E I N D O O R A I R Q U A L I T Y P R O D U C T S P E C I F I C AT I O N S ENERGY RECOVERY SYSTEM FOR L-SERIES ROOFTOP UNITS - 60 HZ Bulletin No. 10533 January 011 Supersedes October 010 800 to 600 cfm Capacity

More information

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101) 500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5

More information

SECTION WELDING FUME EXHAUST SYSTEM

SECTION WELDING FUME EXHAUST SYSTEM SECTION 233500 WELDING FUME EXHAUST SYSTEM PART 1 - GENERAL 1.1 WORK INCLUDES Welding fume exhaust system and controls Accessories Additional System Equipment Engineering Support Commissioning 1.2 RELATED

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381) FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1-1/2, 2, 2-1/2, and 3 Tons Upflow application only Accessory field- installed electric heat kits available in, 7., or 10 kw 208/230-1-

More information

PHR5. Product Specifications

PHR5. Product Specifications PHR5 Product Specifications UP to 15.5 SEER, UP to 12.5 EER, PACKAGE HEAT PUMP UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced R

More information

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls UNIT OBJECTIVES After studying this unit, the reader should be able to Describe and identify power- and non-power-consuming Describe

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES Product Data CC5A, CD5A Heating/Cooling Coil Sizes A018 thru W060 The CC5A and CD5A evaporator coils incorporate proven standards for reliable system operation and performance throughout the life of a

More information

VAV TERMINAL UNITS. VVD VAV Diffusers

VAV TERMINAL UNITS. VVD VAV Diffusers Introduction ASLI VAV diffusers, VVD are variable air volume diffuser for supply air in variable air volume system. In many conventional HVAC systems, multiple work spaces are controlled by a single thermostat.

More information

SINGLE DUCT AIR TERMINAL UNITS

SINGLE DUCT AIR TERMINAL UNITS AIR terminal units AIR TERMINAL UNITS MODEL NUMBER LEGEND XXXXX XXX -XXXX Model TH TL THECO Inlet Size (04, 05, 06, etc.) Generation 5, 6, 7 The METALAIRE single duct terminal units are at the core of

More information

Energy Recovery Laboratory Exhaust

Energy Recovery Laboratory Exhaust Energy Recovery Laboratory Exhaust Model Vektor -ERS For Vektor-M, MH and MS Systems January 2018 Model Vektor -ERS Greenheck s Vektor -ERS is a pre-engineered laboratory exhaust energy recovery system.

More information

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15 ENVIRONMENTALLY SOUND REFRIGERANT FMA4X, FMA4P Product Specifications APARTMENT FAN COILS ALL MODELS 1 1/2, 2, 2 1/2, and 3 Tons Upflow application only Accessory field installed electric heat kits available

More information

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Air Measuring Products. AMS Thermal Dispersion Pressure Differential Air Measuring Products AMS Thermal Dispersion Pressure Differential August 2014 1 Airflow Measuring Technologies Greenheck airflow measuring products are available with either differential pressure based

More information

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404) 500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor

More information

AVXC20. High-Efficiency, Comfortnet-Compatible, Variable-Speed, Inverter Drive Split System Air Conditioner. Cooling Capacity : 23,600 53,000 BTU/h

AVXC20. High-Efficiency, Comfortnet-Compatible, Variable-Speed, Inverter Drive Split System Air Conditioner. Cooling Capacity : 23,600 53,000 BTU/h AVXC20 Cooling Capacity : 23,600 53,000 High-Efficiency, Comfortnet-Compatible, Variable-Speed, Inverter Drive Split System Air Conditioner Contents Nomenclature... 2 Product Specifications... 3 Expanded

More information

Si Series Model CE Residential Geothermal Heat Pump

Si Series Model CE Residential Geothermal Heat Pump Si Series Model CE Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features CE Model 025-071 5 Models: 025,

More information

Performance Rating of Single Package Vertical Air-Conditioners And Heat Pumps

Performance Rating of Single Package Vertical Air-Conditioners And Heat Pumps ANSI/AHRI Standard 390 2003 Standard for Performance Rating of Single Package Vertical Air-Conditioners And Heat Pumps IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify

More information

Submittal. Holder Construction Company. Reviewed. Reviewed as Noted. Rejected. 1. Updates per Bulletin #4

Submittal. Holder Construction Company. Reviewed. Reviewed as Noted. Rejected. 1. Updates per Bulletin #4 Holder Construction Company 230 Peachtree Street NW, Suite 1250 Atlanta, GA 30303 Submittal Project Telephone #404.688.6233 Project Name: Submittal Number: Submittal Description: Submittal Review Date:

More information

CAS. Product Specifications

CAS. Product Specifications CAS Product Specifications COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 to 150 models Terminal

More information

MODULAR AIR HANDLING UNITS GAH SERIES

MODULAR AIR HANDLING UNITS GAH SERIES MODULAR AIR HANDLING UNITS GAH SERIES 15 Models with Air Flows from 2,250 Cu.m/hr upto 77,800 Cu.m/hr Suitable for both Standard and District Cooling Applications GAH-TC-10-13 CONTENTS Design 2 Various

More information

VCD-23. Flange Options. Size Limitations

VCD-23. Flange Options. Size Limitations Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators

More information

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES FFMA Base Series Fan Coil Sizes 018 thru 037 Product Data A13417 FEATURES The FFMA Series Fan Coil unit is primarily designed for apartment applications as an upflow only indoor fan coil for split -system

More information

M E M O R A N D U M. DATE: September 13, 2012 TO: Orcutt Winslow Partnership 3003 N. Central Ave. Phoenix, AZ Tracy Lee FROM: Michael Olson, CPD

M E M O R A N D U M. DATE: September 13, 2012 TO: Orcutt Winslow Partnership 3003 N. Central Ave. Phoenix, AZ Tracy Lee FROM: Michael Olson, CPD DATE: September 13, 2012 M E M O R A N D U M TO: FROM: Orcutt Winslow Partnership 3003 N. Central Ave. Phoenix, AZ 85012 Tracy Lee Michael Olson, CPD PROJECT NO. 10251 PROJECT: RE: Ashlyn Dyer Therapy

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT 50JZ (50Hz.)-C1SB 50JZ 7 to 14 kw (024-048) STANDARD EFFICIENCY SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB

More information

ANSI/AHRI Standard 881 (SI) with Addendum Standard for Performance Rating of Air Terminals

ANSI/AHRI Standard 881 (SI) with Addendum Standard for Performance Rating of Air Terminals ANSI/AHRI Standard 881 (SI) with Addendum 1 2011 Standard for Performance Rating of Air Terminals Approved by ANSI on October 27, 2011 WITH ADDENDUM 1, PERFORMANCE RATING OF AIR TERMILS June 2012 Note:

More information

Model 8144NC Fresh Air Ventilator

Model 8144NC Fresh Air Ventilator Model 8144NC Fresh Air Ventilator Installation and Operating Instructions MOUNTING BRACKETS WIRE ENTRY LOCATION INTEGRAL PRESSURE PORTS (PORT ON INLET SIDE NOT SHOWN) OVAL OUTLET COLLAR FOR 6" DIAMETER

More information

Products for Indoor Air Quality and Control

Products for Indoor Air Quality and Control Products for Indoor Air Quality and Control Constant Volume Fan Powered Units AC_J Series ECM Motor Technical Guide Page 1 Table of Contents General Information Page Number ECM Motor Introduction 3 Design

More information

Tranquility. Large Vertical. Revised: 08 February, Submittal Data - S-I Units. Performance Data. Electrical Data. Unit Designation: Job Name:

Tranquility. Large Vertical. Revised: 08 February, Submittal Data - S-I Units. Performance Data. Electrical Data. Unit Designation: Job Name: Tranquility Large Vertical (TLV) Series Submittal Data Models TLV08-300 50Hz - HFC-10A English Language/S-I Units Submittal Data - S-I Units Unit Designation: Job Name: Architect: Engineer: Contractor:

More information

INFINITY ZONING QUICK START GUIDE

INFINITY ZONING QUICK START GUIDE Infinity Zoning Quick Start Page 1 of 7 INFINITY ZONING QUICK START GUIDE INTRODUCTION Infinity Zoning incorporates cutting edge technology that sets it apart from any other zoning system on the market

More information

Engineering Bulletin. Recirculation Energy Recovery Unit Controls CLCH-PRB009-EN

Engineering Bulletin. Recirculation Energy Recovery Unit Controls CLCH-PRB009-EN Engineering Bulletin Recirculation Energy Recovery Unit Controls Introduction The following represents just one of many configurations that are possible with the Trane Climate Changer air handler with

More information

Start-Up, Operation and Service Instructions

Start-Up, Operation and Service Instructions Article I. Krueger Proportional LineaHeat W/ Discharge Temperature Start-Up, Operation and Service Instructions SAFETY NOTE Air-handling equipment will provide safe and reliable service when operated within

More information

Constant Airflow Regulators & Registers

Constant Airflow Regulators & Registers Constant Airflow Regulators & Registers The Simple Solution The model CAR-II Constant Airflow Regulator is a modulating orifice that automatically regulates airflows in duct systems to constant levels.

More information

FMU4X, FMC4X FMU4Z, FMC4Z

FMU4X, FMC4X FMU4Z, FMC4Z HORIZONTAL FAN COILS FMU4Z and FMC4Z 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2, 2 1/2, and 3 Tons Horizontal application only Accessory field installed electric heat kits available in 3, 5,

More information

Greater Cleveland Regional Transit Authority

Greater Cleveland Regional Transit Authority Greater Cleveland Regional Transit Authority SUMMARY OF PROPOSED AWARD Furnishing up to Two Hundred Forty (240) Low Floor 40-ft. Coaches, Training, Special Tools and Spare Parts over a Five (5) Year Contract

More information

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Venturi FX VFX Series v100 Issue Date: 11/22/16 2016 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Safety Precautions... 1 Caution to Contractors...1

More information