with auxiliary motor and battery-operated emergency retraction set cover panel installation between guide rails

Size: px
Start display at page:

Download "with auxiliary motor and battery-operated emergency retraction set cover panel installation between guide rails"

Transcription

1 WAREMA external venetian blind with auxiliary motor and battery-operated emergency retraction set cover panel installation between guide rails Installation instructions For qualified technicians only Valid from 25 June 2012 Document no. [M _0] EN

2 Table of contents Table of contents Introduction... 3 Information on safety... 3 Explanation of symbols and signs... 3 Important safety information... 4 Information on the target group and application of these instructions... 6 Product information... 6 Parts description... 6 Technical data/accessories... 7 Intended use... 7 Wind speed limits... 8 CE conformity... 9 Installation Tools Unpacking the external venetian blind Scope of delivery Marking the position of the external venetian blind Installing the guide rails Preparing the cover panel Preparing the feedthrough for the power line Installing the cover panel Attaching and centring the top rail Performing a functional check with the external venetian blind Final tasks [M _0] - EN / Page 2 of 24 Subject to change without notice

3 Introduction 1 Introduction 1.1 Information on safety 1.2 Explanation of symbols and signs Safety information and symbols are contained in the appropriate parts of the text. It is important to follow these instructions in the interests of personal safety. Failure to comply with these instructions when operating the product may result in personal injury and/or property damage. Failure to comply with these instructions relieves WAREMA of liability. Warnings are marked with these symbols in the instructions. Read the instructions carefully before starting with the installation. Read and observe all warnings. Please observe all safety, installation, operating and setting instructions. Observe all warnings on the product. Symbol Use/explanation DANGER Identifies an imminent danger that may result in death or serious injury if not prevented. WARNING Identifies a potential danger that may result in death or serious injury if not prevented. CAUTION Identifies a potential danger that may result in minor injury or property damage if not prevented. Read the installation instructions. Note Important information on how to proceed and on the content of these instructions. Activity/step List [M _0] - EN / Page 3 of 24 Subject to change without notice

4 Introduction 1.3 Important safety information The safety instructions and warnings described here are intended to safeguard your health as well as protect the product. Please read the following points carefully. Damage resulting from inappropriate use or the failure to observe these instructions or safety information is not covered by the guarantee. Liability will not be accepted for secondary damage. General conditions If the external venetian blind with auxiliary motor and battery-operated emergency retraction set is used at escape doors and emergency windows to protect against summer heat and glare and to provide privacy, the batteryoperated emergency retraction set is activated in case of an emergency to clear the escape route. Danger to life and product damage from incorrect procedure during commissioning! If the following points are not followed, no warranty can be granted for functional problems, soiling and damage. The external venetian blind must remain out of service until the commissioning has been released. Raise the external venetian blind fully to clear the escape route. The external venetian blind is sufficiently raised if the external venetian blind disappears into the cover panel (if present), or if the escape door or emergency window can be opened. Installation preparations Correct functioning of the external venetian blind with auxiliary motor and batteryoperated emergency retraction set and, therefore, unblocking of the escape doors and emergency windows in case of an emergency are only ensured if you follow our safety instructions closely. Danger to life and limb if the WAREMA control is not used! It must be ensured that the external venetian blind is only activated by the associated electronic battery-operated control. Manipulations by third parties must be excluded. It is important that the external venetian blind is not blocked by dirt or obstacles. Danger to life from restrictions of the escape route while during installation of the external venetian blind with auxiliary motor and battery-operated emergency retraction set! Before beginning installation, inform the safety officer that the escape route is available only to a limited extent. It must be ensured that the building can be evacuated along a different escape route. Risk of injury and damage to the product from incorrect installation! Comply with the specified installation steps and instructions. Install the product only if it is in technically perfect condition. Before installation, check the mounting substructure to make sure it can bear the loads. Widely cordon off the installation site and the projection area of the external venetian blind. [M _0] - EN / Page 4 of 24 Subject to change without notice

5 Introduction Packaging Risk of damage to the product Risk of suffocation! Do not leave the packaging material lying around, and keep children away from small parts. Plastic film, polystyrene, small parts, etc., can be very dangerous for children to play with. Electrical connection Electric shock from incorrect installation! The electrical installation must be performed by a certified electrician in accordance with the electrical installation regulations published by the Association of German Electrical Engineers (VDE 0100) or the standards and regulations of the country in which the product is being installed. The specialist must observe the installation instructions included with the electrical appliances. Before commissioning the product, remove all lines that are not required. Disconnect any devices that are not needed for operation. Risks posed by the product Risk of crushing and injury! When raising and lowering the product and when making the electrical connection of the system, do not reach into movable parts (e.g. between the bottom rails and/or slats). Transport Risk of injury from unmonitored or improper operation of the external venetian blind. Install the operating elements of the product and the emergency push button of the external venetian blind with auxiliary motor and battery-operated emergency retraction set outside of the projection area but within view of the product at a height that meets the national regulations for the disabled. Instruct customers on how to use the product. Product damage and property damage from carelessness during operation! The projection area of the external venetian blind must be kept clear of fixed and movable obstacles. Risk of injury and product damage from inappropriate transport! The gross axle weight rating and gross weight rating of the transport vehicle must not be exceeded. A loaded vehicle may handle differently. Secure the transported goods appropriately and safely. Protect the packaging of the product against moisture. Soaked packaging may work loose and cause accidents. [M _0] - EN / Page 5 of 24 Subject to change without notice

6 Introduction/product information 1.4 Information on the target group and application of these instructions Target group These installation instructions are intended for qualified fitters. Knowledge of safety at work, accident prevention regulations, working with ladders and scaffolding, handling and transporting long and heavy items, using fixation materials, assessment of the building fabric, commissioning and operation of the product is required. If any of these qualifications are unavailable, the work must be carried out by a specialist fitting company. 2 Product information 2.1 Parts description The electrical installation must be performed by a certified electrician in accordance with the electrical installation regulations published by the Association of German Electrical Engineers (VDE 0100) or the standards and regulations of the country in which the product is being installed. Contents These instructions are part of the operating instructions and are an integral part of this product. These instructions contain important information on transport, handling, installation and commissioning of this item. They describe the basic installation of the WAREMA external venetian blind with auxiliary motor and battery-operated emergency retraction set, mounted in the cover panel between the guide rails. Other versions or special solutions are not dealt with. Permissible activities Aside from the activities described for the product in these installation instructions, alterations, additions and maintenance work on the product are not permitted without the written approval of WAREMA. Fig. 1: 1 Top rail 8 Guide rail 2 Bracket 9 Bottom rail 3 External venetian blind drive (motor) 10 Lifting tape 4 Top rail bracket 11 Emergency push button* 5 Auxiliary motor 12 Battery-operated control* 6 Cover panel 13 Tilting tape 7 Guide rail bracket Parts overview for external venetian blind with auxiliary motor and battery-operated emergency retraction set, mounted in cover panel between the guide rails dd * The emergency push button and the batteryoperated control together make up the emergency retraction set [M _0] - EN / Page 6 of 24 Subject to change without notice

7 Product information 2.2 Technical data/accessories Weight Flat slat Beaded slat Dim-out slat Tab. 1: Value Weights for external venetian blind Approx. 2.7 kg/m² Approx. 3.1 kg/m² Approx. 3.2 kg/m² Additional data on electric drive (external venetian blind drive) Parameter Rated torque Power Current consumption Rated speed Rated voltage Frequency D339 9 Nm 131 W 0.57 A 26 rpm 230 VAC 50 Hz Degree of protection IP 54 Short-term operation (S2) Limit switch range Tab. 2: 4 minutes 97 revolutions Details on the external venetian blind drive The technical data on the control can be found in the associated installation instructions. Accessories A wide range of control devices is available for the sun shading system to give you optimum control of the product. These controls can be combined with the batteryoperated control of the external venetian blind with auxiliary motor and battery-operated emergency retraction set. However, this must be clarified on a case by case basis. Do not use the external venetian blinds in icy or frosty weather. Liability cannot be accepted for damage to the sun shading system resulting from the operation under icy conditions. We recommend the use of an ice monitoring system. 2.3 Intended use The external venetian blind with auxiliary motor and battery-operated emergency retraction set is an external sun shading system used at escape doors and emergency windows to protect against summer heat and glare and to provide privacy. In the projection area of the external venetian blind, there must be no obstacles/protruding parts (for example, door stop), especially on the door leaf, that would prevent raising of the external venetian blind while also opening the escape door at the same time. If this cannot be prevented, other technical measures must ensure that the closure on the door leaf can be opened before the escape route is cleared by the external venetian blind with auxiliary motor and batteryoperated emergency retraction set. However, this must always be planned and approved by the architect/planner or the local building authority. Inappropriate use may result in significant danger. All external venetian blinds for external use are designed for a wind load of 1.1 kn/m² (DIN 1055). The directive entitled "Wind loads for construction of closures and awnings when retracted Section 5.1.1" 1 defines the positions at which these products can be installed without requiring special precautions. To ensure that the external venetian blind with auxiliary motor and battery-operated emergency retraction set can be activated reliably, the external venetian blind must always be operated via the associated electronic battery-operated control. Additional loads on the external venetian blind with auxiliary motor and battery-operated emergency retraction set, such as from suspended objects, could damage the product or cause it to fall (for example, tearing of the lifting tapes), or cause the external venetian blind with auxiliary motor and battery-operated emergency retraction set to fail, and are therefore also not permitted. The intended use also includes observing these instructions and the installation conditions. 1 Published by the Bundesverband Rollladen + Sonnenschutz e.v. and Bundesverband Konfektion Technischer Textilien e.v. - BKTex [M _0] - EN / Page 7 of 24 Subject to change without notice

8 Product information Compliance with legal provisions and countryspecific regulations on site is the responsibility of the ordering party/building owner. There may be regional regulations and conditions that prohibit use of the external venetian blind with auxiliary motor and battery-operated emergency retraction set. However, each and every case cannot be investigated by WAREMA. Use of the battery-operated control for external venetian blinds with auxiliary motor and batteryoperated emergency retraction set is only permissible in normal room climates. The intended use only applies in the specified temperature range (as per the technical data in the installation instructions). Use in damp locations (such as swimming pools) is not permissible. The heating from outside influences must be less than the intrinsic warmth. 2.4 Wind speed limits For external venetian blinds, the use of wind speed limits (see Tab. 3) depends on the particular product type. If the wind speed limits are reached, the external venetian blind must be retracted. It is recommended that the wind sensors be set to the lowest value, e.g. to 13.5 m/s for Beaufort 7. Basis of Table 3: Slat facade distance: 100 mm Slat thickness: 0.4 mm Order height: < 2400 mm Order width Width up to 1500 mm Width up to 2000 mm Width up to 2500 mm Width up to 3000 mm Width up to 3500 mm Tab. 3: Beaded slat with rail guidance m/s (7 Bft.) m/s (7 Bft.) m/s (7 Bft.) m/s (7 Bft.) m/s (6 Bft.) Flat slat with rail guidance m/s (7 Bft.) m/s (6 Bft.) m/s (6 Bft.) m/s (6 Bft.) m/s (5 Bft.) Recommended wind speed limits (details in m/s and Beaufort number) The table values (Beaufort number) should be modified in the following cases: 1. Facade distance > 100 to 300 mm: Reduce value by 1 > 300 to 500 mm: Reduce value by 2 > 500 mm: Table not applicable 2. Material thickness < 0.4 mm: Reduce value by 1 The external venetian blinds will only meet the requirements of the stated wind speed limits when mounted if: the recommended number of brackets, holders and guides are mounted the instructions from the manufacturers for the dowels are followed When mounting on wood, a wind speed limit cannot be given due to the variability of this building material. [M _0] - EN / Page 8 of 24 Subject to change without notice

9 Product information 2.5 CE conformity CE conformity is certified, and the corresponding EC declaration of conformity is part of these product-specific operating and maintenance instructions. To maintain this state and to ensure that the product can be safely installed and commissioned, you must adhere to the installation instructions. The CE declaration of conformity of the battery-operated control is contained in the separate installation instructions. Name: WAREMA Renkhoff SE Year of declaration of conformity: 2011 Head office: Hans-Wilhelm-Renkhoff-Straße Marktheidenfeld Germany Standard: DIN EN Product: External venetian blinds Intended use For outdoor installation Wind class: 0 2 Noise emission level: < 70 db (A) 3 2 Specification of wind class 0, since standard test stands cannot be used in the applicable test standard due to mechanical inadequacies of the test description. Depending on the model and the installation location, the product can be used up to the wind speed limit specified above (see Tab. 3). 3 In a standard installation of the product on a test stand, the noise emission level is <70 db(a). This value may vary depending on the installation. [M _0] - EN / Page 9 of 24 Subject to change without notice

10 3 Installation 3.1 Tools The installation tasks may only be performed by a qualified specialist (for example, roller shutter and venetian blind builder/roller shutter and sun shading system mechatronics technician); this means that the authorised qualified specialist described below must have these special qualifications. At least two people are required for the installation. Application drawings must be followed. WARNING Risk of injury and falling! Climbing aids must be positioned securely, provide enough support and have a sufficiently high load-bearing capacity. When working at great heights, the appropriate provisions must be made to protect against falling. Under no circumstances should persons use the external venetian blind as a means of support. Tool/aid Size Use Tape measure/spirit level Pencil/pointed object Power drill Drill bits (collection) Drill bits (depending on the substructure) 10 Pencilling in of fixing points Fixing holes Drilled holes (depending on substructure) Power line feedthrough Conical drill 33 Plug-in grommet STM 32 Cross-head screw driver Ratchet with nut/open-end spanner Ratchet with nut/open-end spanner Ratchet with nut/open-end spanner Test cable Tab. 4: Size 2 Size 8 Size 10 Size 13 Tools and their use End cap Clamping plates/fixing bracket Attaching side cover to angle bracket Angle bracket to angle bracket Receiver Guide rail bracket Trial run of external venetian blind [M _0] - EN / Page 10 of 24 Subject to change without notice

11 3.2 Unpacking the external venetian blind Find another use for the discarded packaging material or take it to your local recycling centre. CAUTION Risk of product damage from failure to exercise care when unpacking! Be careful not to damage the lifting and tilting tapes when removing the packaging material. Remove the packaging material (plastic film) of the blind at the top rail. Carefully unpack the external venetian blind and individual parts. Remove the spacers between the top rail and the slats. External venetian blinds with auxiliary motor Cover panel and loose side cover Guide rails Guide rail bracket Instructions/handover report Battery pack Screw DIN 933 M 8 x 30 (for attaching the guide rail bracket to the receiver for guide rail type 7/8/10) Screw DIN 7380 M 8 x 30 (for attaching the guide rail bracket to the receiver for guide rail type 9) Washer DIN 125 A 8.4 (for attaching the guide rail bracket to the receiver) Nut DIN 985 M 8 (for attaching the guide rail bracket to the receiver) Screw DIN x 20 (for attaching the side cover to the angle bracket) Washer DIN 9021 A 6.4 (for attaching the side cover to the angle bracket) Parts description Top rail bracket Dispose of the packaging material correctly. 3.3 Scope of delivery Check the scope of delivery. n x Emergency push button Check the scope of delivery using the delivery note. Check the parts to make sure they are not damaged. If any items are damaged or not as specified in the order, stop the installation and contact WAREMA. 1 x 1 x Tab. 5: Battery-operated control Overview of additional parts delivered for external venetian blind with auxiliary motor and batteryoperated emergency retraction set [M _0] - EN / Page 11 of 24 Subject to change without notice

12 3.4 Marking the position of the external venetian blind Guide rail type 7 Guide rail type 7 and type 8 Guide rail type 9 dd dd dd H External venetian blind height Fig. 2: Dimensional drawing for external venetian blind with auxiliary motor and battery-operated emergency retraction set (all dimensions in mm) dd Guide rail type 9 and type 10 B Order dimension L Slat size BL Fig. 3: Cover panel length Guide rail positions (all dimensions in mm) Transfer the position of the external venetian blind to the mounting substructure. dd for cover panel type 06/08 37 for cover panel type 09 [M _0] - EN / Page 12 of 24 Subject to change without notice

13 3.5 Installing the guide rails Marking and drilling the fixing points DANGER Risk of injury from falling external venetian blinds! Select fixing material that is suitable for the substructure. Observe the listed weights when planning the fixing material. You must use the specified number of guide rail brackets/guide rail fixations. The fitter is responsible for the correct selection of fixing materials and adhering to the installation specifications of the fixing material manufacturer. Mounting substructure Masonry (concrete B15) Aluminium/PVC with steel core Fixation suggestion Screw DIN 571-A2 6 x 60 Washer DIN 9021-A2 A6.4 Dowel S8 Screw DIN 7976-A2 6.3 x 38* Washer DIN 9021-A2 A6.4 Wood Screw DIN 571-A2 6 x 50* Transom and mullion facade Tab. 6: Washer DIN 9021-A2 A6.4 Threaded bolt M 8 EPDM sealing washer Stop nut DIN 934 M 8 Washer DIN 9021 A8.4 Nut DIN 934 M 8 Fixation suggestions for guide rail brackets type H101/H115 (selected mounting substructures) * Screw with seal coating prevents water from penetrating into the screw connection. Guide rail type Permissible guide rail brackets Guide rail length dd dd dd dd dd dd dd dd H101 H115 Fixing points (base plate with offset) dd dd To 3000 mm To 5000 mm Tab. 7: 2 pieces 3 pieces Number of guide rail brackets H101/115 depending on the guide rail length [M _0] - EN / Page 13 of 24 Subject to change without notice

14 Measure the guide rail brackets and pencil them in onto the mounting substructure. (See also Fig. 3/p. 12). Transfer the fixing template of the guide rail brackets onto the substructure. Securing the guide rail Check the position of the receivers on the guide rail against the mounted guide rail brackets. Pencil in the fixing positions centrally to permit corrections later on. Drill the fixing holes depending on the substructure. * The first guide rail bracket from the top must be approx. 100 mm below the cover panel Attaching the guide rail brackets If the positions do not match: Release the nuts DIN 934 M 6 on the receivers. Push the receivers into position. Tighten the nuts DIN 934 M 6 again. Check the position of the angle brackets on the guide rails. Check that the substructure is even by holding a suitable tool (e.g. a spirit level) against it and correct any unevenness. Fix the guide rail brackets to the substructure using suitable fasteners. If the positions do not match: Release the nuts M 6 on the angle bracket. Slide the angle bracket into position. Tighten the nuts M 6 again. [M _0] - EN / Page 14 of 24 Subject to change without notice

15 Aligning the guide rails Connect the guide rail brackets. Insert screws DIN 7380 M 8 x 30 (for guide rail type 9) or DIN 933 M 8 x 30 (for guide rail type 7/8/10) with washers DIN 125 A 8.4. The head of the screw must face toward the slat. Mount the screws with nuts DIN 985 M 8 and with washers DIN 125 A 8.4. Do not tighten the nuts yet. Align the guide rails and tighten nuts M 8. If needed, define assist points in the upper area of the guide rails for measuring the diagonals. Check the guide rails to ensure they have the same height (B) and are parallel (X1 = X2 ± 1 mm). Measure diagonals "D1" and "D2". If D1 = D2, the guide rails are parallel and at right angles. 3.6 Preparing the cover panel WARNING Risk of injury from wrong top rail brackets in external venetian blind with auxiliary motor and battery-operated emergency retraction set! In external venetian blinds with auxiliary motor and battery-operated emergency retraction set, special top rail brackets are used that prevent twisting or shifting of the top rail. Cover panel type Replace the installed top rail brackets with the supplied top rail brackets (accessories). dd dd Cover panel type Drilling the outlet opening for the on-site power line Cover panel type 09 Dimension X 06/08 80 mm mm Tab. 8: Position for outlet opening in the cover panel dd Before installing the cover panel, check whether it makes sense to install the external venetian blind from above. If so, fall protection must be attached to the guide rails (such as adhesive tape). [M _0] - EN / Page 15 of 24 Subject to change without notice

16 Mark the position of the outlet opening for the onsite power line in the cover panel. Drill the outlet opening with 33 (see Tab. 8)! Deburr the drilled hole and remove the shavings from the cover panel. Press in the plug-in grommet. Open the top rail brackets for the emergency retraction set (in accessories). Mount the top rail brackets for the emergency retraction set in the same position. 3.7 Preparing the feedthrough for the power line WARNING Short circuit due to damage to the power line from unclean feedthrough. Avoid or remove sharp edges around the feedthrough. For cover panels that will later be plastered on the front side, we recommend additional brackets for stiffening. Changing the top rail brackets Remove the mounted top rail brackets. Execute the on-site feedthrough according to the applicable standards and regulations (e.g. use of plug-in grommets). The VDE (German Association for Electrical, Electronic & Information Technologies) regulations and the legal requirements and standards of each country for sealing line feedthroughs must be followed. CAUTION Product damage! 1 Auxiliary motor L Slat size 2 Top rail bracket/bracket 3 Tilting tape/lifting tape 4 External venetian blind drive (motor) Fig. 4: X End distance = 250 mm Dimensional drawing for top rail bracket/bracket (all dimension in mm) dd When drilling, take any electrical cables, water pipes, and so on into consideration. Measure and pencil in the feedthrough. Drill the feedthrough with a 10 mm drill bit. Drill the feedthrough to its full width with a 20 mm drill bit. Check the position of top rail brackets/brackets against Fig. 4. If necessary, shift the brackets in the cover panel to the correct position. [M _0] - EN / Page 16 of 24 Subject to change without notice

17 3.8 Installing the cover panel Each cover panel is labelled (see Fig. 5). Screw the loose side cover onto the angle bracket with the washers DIN 9021 A 6.4 and screws DIN 933 M 6 x 20. Do not tighten the screws yet as the side cover still needs to be moved. Slide the cover panel on the loose side cover. Fig. 5: 1 Internal testing position Labelling on cover panel dd WA number and order number Position the cover panel on the opposite side against the angle bracket. Position the cover panel on the opposite side against the angle bracket. Attach the cover panel to the angle bracket with washers DIN 9021 A 6.4 and screws DIN 933 M 6 x 20. Align the cover panel. Tighten the screws of the loose side cover. [M _0] - EN / Page 17 of 24 Subject to change without notice

18 Insert the on-site power line through the plug-in grommet. Connect the plug-in connector to the on-site power line. Removing the end caps for the guide rails Release the screws on both sides. Note the accompanying document entitled "Setting instructions and wiring diagram". Pull the end caps out of the guide rails. 3.9 Attaching and centring the top rail Check every position in which the external venetian blind with auxiliary motor and battery-operated emergency retraction set is mounted to ensure that the right top rail brackets (for the emergency retraction set) were installed (see Fig. 6). If the described procedure is not possible, notches must be introduced into the guide rails (installation openings). Follow the accompanying installation notes. Lowering the external venetian blinds Connect the motor line with STAK 3 with the STAK 3 test cable. Close the safety catch. Plug the power plug into the power socket. Lower the external venetian blinds (at least to the level of the cover panel). Remove the test cable. [M _0] - EN / Page 18 of 24 Subject to change without notice

19 Inserting the external venetian blind into the guide rails CAUTION Product damage through on-site power line! Keep the on-site power line out of the range of movement of the external venetian blind. Attaching the top rail to the top rail brackets WARNING Risk of injury from falling top rail! Do not release the external venetian blinds until the top rail brackets have been closed. Position the top rail against the guide rail end or installation opening. The order number on the top rail must face the facade. Introduce the slats from beneath or through the installation opening into the guide rails. 1 Top rail 3 Screw DIN 7985 M 5 x 16 2 Top rail bracket 4 Screw DIN7985 M 4 x 10 Fig. 6: Attaching the top rail to the top rail brackets Attach the top rail (1) to the top rail brackets (2). The order number on the top rail must face the facade. dd Close the top rail brackets (2). Centre the top rail (1) between the top rail brackets (2). [M _0] - EN / Page 19 of 24 Subject to change without notice

20 Securing the top rail 3.10 Performing a functional check with the external venetian blind The motors are preset at the factory. It is not permissible to change the limit positions. 1 Screw DIN 7985 M 5 x 16 Fig. 7: Securing the top rail Tighten the screws (1). Raise the external venetian blind to the upper limit position. Installing the end caps for the guide rails Press the end caps into the guide rails. dd DANGER Danger to life and product damage from incorrectly set limit positions! Do not change the lower limit position of the motor. It is not permitted to change the factory setting. The escape door could be blocked if it becomes impossible to raise the sun shading system. Connect the programming cable to the plug-in connector of the external venetian blind drive. Check the limit positions of the external venetian blind by lowering and raising it multiple times. In the lower limit position, the bottom rail should not rest on an object. The blind must hang freely in the lifting tapes. Screw in the screws on both sides. Close the installation opening in the guide rail again. Follow the accompanying installation notes. [M _0] - EN / Page 20 of 24 Subject to change without notice

21 Raise the external venetian blind with auxiliary motor and battery-operated emergency retraction set fully to the upper limit position to clear the escape route. The external venetian blind is sufficiently raised if the external venetian blind disappears into the cover panel (if present), or if the escape door or emergency window can be opened. Remove the test cable. Do not use the external venetian blind with auxiliary motor and battery-operated emergency retraction set until the battery-operated control has been taken into service. DANGER Danger to life and short circuit from damage to motor line! Damage can lead to a short circuit and/or the required emergency retraction time is not reached. Keep the motor line away from all moving parts. To secure the motor line, press it into the line clamps on the top rail Final tasks DANGER Danger to life from unintended use (see p. 7)! The installation location and installation situation have been checked for suitability. If Section 2.3 is not met in its full scope, the safety officer must be informed. DANGER Danger to life from functional problems due to incorrect implementation of the installation steps. Check the installation steps (checklist). Improve on the installation steps if necessary. Check the implementation of the installation steps that are needed for the reliable functioning of the external venetian blinds against the following checklists. Installation step... performed (from these installation instructions) The motor line is secured in such a way that it cannot come into contact with moving parts. A functional check of the external venetian blind was performed and the external venetian blind exhibited smooth running behaviour without a jerking motion. The motor limit positions have not been changed P To ensure reliable operation, follow all of the other points in the instructions as well. Hand over to the customer the operating and maintenance instructions with the inspection log for checking the external venetian blind with auxiliary motor and battery-operated emergency retraction set (one instruction manual per external venetian blind). [M _0] - EN / Page 21 of 24 Subject to change without notice

22 DANGER Functional problems and product damage due to incorrect operation in frosty conditions! The external venetian blind can freeze when temperatures drop below the specified temperature (+ 3 C). Do not operate the external venetian blind if it is frozen. Avoid applying force to the external venetian blind if it is frozen. The external venetian blind can become damaged. In wintry temperatures, retract the product to the upper limit position and take it out of service. If the external venetian blind is controlled by a higher level control without ice monitoring, the control can optionally be set in such a way that the external venetian blind stays in the upper limit position and can no longer be lowered by the control or local operating elements. We recommend the use of an ice monitoring system. Install and connect the battery-operated control and other components according to the installation instruction. Connect the external venetian blind drive according to the included setting instructions and wiring diagram. Train the operator in how to operate the external venetian blind with auxiliary motor and batteryoperated emergency retraction set. This is only possible after the battery-operated control has been installed. Hand over the installation instructions of the battery-operated control to the operator. Fig. 8: Attaching the label dd Notify the operator that the label should be applied in the area of the operating element. [M _0] - EN / Page 22 of 24 Subject to change without notice

23 [M _0] - EN / Page 23 of 24 Subject to change without notice

24 WAREMA Renkhoff SE Hans-Wilhelm-Renkhoff-Straße Marktheidenfeld, Germany info@warema.de

with auxiliary motor and battery-operated emergency retraction set cable guidance

with auxiliary motor and battery-operated emergency retraction set cable guidance WAREMA external venetian blind with auxiliary motor and battery-operated emergency retraction set cable guidance Installation instructions For qualified technicians only Valid from 22 June 2012 Document

More information

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions Drive Unit e-drive1 Installation instructions 04/2014 English translation of the original German installation instructions Contents Foreword... 3 Availability... 3 Structural features in the text... 3

More information

Assembly and Operating Instructions

Assembly and Operating Instructions A35AE FU...A150AE FU en Assembly and Operating Instructions Plug-in drives Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be kept safe for

More information

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA 5.52.714.00.1.0 Edition 03.2004 GB Operating and Maintenance Manual for HADEF overhead crane as jointed crane TA Subject to changes. 1 HADEF Table of Contents 1 General Page 3 2 Product description Page

More information

Mod: KLD6-12/35XLAS-N

Mod: KLD6-12/35XLAS-N 12/2011 Mod: KLD6-12/35XLAS-N Production code: 1914070 INSTRUCTION MANUAL LOGIC LINE PLUS HOOD Reseller Stamp for Warranty Dear customer, Above all, thank you for choosing our product and we would like

More information

0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table

0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table Type overview FSR with guide cables or rods Type key FSR P S 0 0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table Cover panel without back-fold: S = small,

More information

GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds

GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds Venetian blind motor: GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds DE FR ES IT Original-Montage- und Betriebsanleitung Original assembly and operating instructions Notice

More information

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type RSBW Assembly and Maintenance Manual Type RSBW Hatschekstr. 36 69126 Heidelberg Germany Tel +49(0)6221 30470 Tel +49(0)6221 304731 info@stieber.de www.stieber.de Stieber Clutch Date of issue: 16/03/2017 GB

More information

GEIGER-GJ56.. For Venetian blinds and exterior blinds

GEIGER-GJ56.. For Venetian blinds and exterior blinds Venetian blind motor: GEIGER-GJ56.. For Venetian blinds and exterior blinds DE FR ES IT Original-Montage- und Betriebsanleitung Original installation and operating instructions XXX Manuel d utilisation

More information

Planar surface gantry EXCM-30. Instructions. Mechanical installation b [ ]

Planar surface gantry EXCM-30. Instructions. Mechanical installation b [ ] Planar surface gantry EXCM-30 Instructions Mechanical installation 804447 605b [8044434] EXCM-30 Translation of the original instructions LOCTITE is a registered trademark of its respective trademark holder

More information

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Installation Guide WBP-Box-IEN103320 IMEN-WBP-BOX Version 2.0 EN SMA Solar Technology AG Table of Contents Table of Contents

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

GEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds

GEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds Motor for Venetian blinds: GEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds DE FR ES IT Original-Montage- und Betriebsanleitung Original assembly and operating instructions Notice originale de montage

More information

HST -LS Interlocking device (Translation of Original Manual)

HST -LS Interlocking device (Translation of Original Manual) Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image

More information

GEIGER-SOLIDline* GEIGER-Touch (GU45..M) for rolling shutters, awnings and screens. Bedienungsanleitung. Operating Instructions. Manuel d utilisation

GEIGER-SOLIDline* GEIGER-Touch (GU45..M) for rolling shutters, awnings and screens. Bedienungsanleitung. Operating Instructions. Manuel d utilisation Tubular motor: GEIGER-SOLIDline* Motor control: GEIGER-Touch (GU45..M) for rolling shutters, awnings and screens DE Bedienungsanleitung Operating Instructions FR Manuel d utilisation ES Manual de instrucciones

More information

GEIGER-SoftPerfection (GR45..E03) for rolling shutters with stoppers and anti-lift device

GEIGER-SoftPerfection (GR45..E03) for rolling shutters with stoppers and anti-lift device Tubular Motor: GEIGER-MODULARline Motor Control: GEIGER-SoftPerfection (GR45..E03) for rolling shutters with stoppers and anti-lift device DE FR ES IT Bedienungsanleitung Operating Instructions Manuel

More information

Oil-free piston compressors KK and piston vacuum pumps KV

Oil-free piston compressors KK and piston vacuum pumps KV Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols

More information

RolTop Roller Blind Drive

RolTop Roller Blind Drive Roller Blind Drive Table Of Contents 13 Operating and installation instructions 1 14 General for instructions 1 14.1 Standards and Directives 1 14.2 Intended use 1 24 Technical data and dimensions 7 24.1

More information

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type AS Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx

More information

2 TONNE TROLLEY JACK

2 TONNE TROLLEY JACK 2 TONNE TROLLEY JACK 61829 IMPORTANT: Please read these instructions carefully to ensure the safe and effective use of this product and save these instructions for future reference. This manual has been

More information

GEIGER-GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply

GEIGER-GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply Venetian blind motor: GEIGER-GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply DE FR ES IT Original-Montage- und Betriebsanleitung Original assembly and operating

More information

Wilo-Control SC-Fire Jockey

Wilo-Control SC-Fire Jockey Pioneering for You Wilo-Control SC-Fire Jockey de en fr Einbau- und Betriebsanleitung Installation and operating instructions Notice de montage et de mise en service nl Inbouw- en bedieningsvoorschriften

More information

Layher Ladders Instructions for Assembly and Use. Quality management certified according to DIN EN ISO 9001:2000 by TÜV-CERT.

Layher Ladders Instructions for Assembly and Use. Quality management certified according to DIN EN ISO 9001:2000 by TÜV-CERT. Layher Ladders Instructions for Assembly and Use Quality management certified according to DIN EN ISO 9001:2000 by TÜV-CERT Ladders CONTENTS 1. INTRODUCTION................................. 3 2. GENERAL.......................................

More information

Assembly instructions

Assembly instructions Please carefully read the assembly instructions before beginning the installation, operation and maintenance of the solar facility. Noncompliance could cause injury to persons or damage to the equipment.

More information

Energy-Saving Under-Cabinet Light. Assembly and safety advice Z30802A-BS Z30802B-BS

Energy-Saving Under-Cabinet Light. Assembly and safety advice Z30802A-BS Z30802B-BS 6 Energy-Saving Under-Cabinet Light Assembly and safety advice 6 Z30802A-BS Z30802B-BS GB / IE Assembly and safety advice Page 3 Table of contents Introduction Proper use...page 4 Description of parts...page

More information

DOCUMENT TYPE = FITTING INSTRUCTIONS ORIGINAL LANGUAGE = ENGLISH. Maximum door weight = 40kg per leaf total system 80kg

DOCUMENT TYPE = FITTING INSTRUCTIONS ORIGINAL LANGUAGE = ENGLISH. Maximum door weight = 40kg per leaf total system 80kg Evolve SIM Kit DOCUMENT TYPE = FITTING INSTRUCTIONS ORIGINAL LANGUAGE = ENGLISH 80kg Maximum door weight = 40kg per leaf total system 80kg Maximum door width 2 x 2mtr Track = 675-1058mm (Up to 2035 mm

More information

WATERFLUX 3070 Quick Start

WATERFLUX 3070 Quick Start WATERFLUX 3070 Quick Start Battery powered electromagnetic water meter Electronic Revision ER 4.3.0_ up to ER 4.3.4_ (SW.REV 4.2.2_ up to 4.2.5_) KROHNE CONTENTS WATERFLUX 3070 1 Safety instructions 4

More information

Operating instructions

Operating instructions Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future

More information

Instruction manual Electric glass door lock Touch-to-open

Instruction manual Electric glass door lock Touch-to-open Instruction manual Electric glass door lock Touch-to-open OPERATING INSTRUCTIONS Touch to open electric glass door lock Operating instructions draft 09-2017_v1 Content 1 General 1.1 Performance Description

More information

Exchange of rollers from the XTS-Mover

Exchange of rollers from the XTS-Mover Service documentation for AT901-0050-0550 and AT9011-00x0-0550 Version: Date: 1.0 0.10.017 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1. Documentation issue

More information

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: ) EN Instructions for Fitting, Operating and Maintenance Canopy Door 1 818 012 RE / (St.: 12.2010) 12.2010 ENGLISH Contents 1 Safety Instructions... 3 1.1 Qualified persons... 3 1.2 Symbols and signal words

More information

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL MOTORTECH Tools & Test Equipment for Ignition Systems P/N 01.10.019 Rev. 01/2013 Copyright Copyright 2012 MOTORTECH GmbH. All rights reserved. Distribution

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

Adjustable Speaker Mount GRAVIS 8

Adjustable Speaker Mount GRAVIS 8 Adjustable Speaker Mount GRAVIS 8 User's Manual Translation of the original instructions Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstraße 14 D-30179 Hannover TEL +49 (0)

More information

Adjustable Speaker Mount GRAVIS 12

Adjustable Speaker Mount GRAVIS 12 Adjustable Speaker Mount GRAVIS 12 User's Manual Translation of the original instructions Version 3.3 Released: 19.01.2017 Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstraße

More information

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 0283, 0293 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 The operating instructions...2 2 Intended

More information

Installation Instructions. Ultimate Screen. English Version 2.3

Installation Instructions. Ultimate Screen. English Version 2.3 Installation Instructions Ultimate Screen English Version 2.3 REMARKS. This manual simply describes the rules governing use and installing of the Ultimate Screen Blind. For different versions we would

More information

Instructions for Fitting, Operating and Maintenance

Instructions for Fitting, Operating and Maintenance EN Instructions for Fitting, Operating and Maintenance Retractable Door 1 818 024 RE / 10.2011 ENGLISH Contents 1 Safety Instructions... 3 1.1 Qualified persons... 3 1.2 Symbols and signal words used...

More information

Operating Instructions CYR52

Operating Instructions CYR52 BA01300C/07/EN/02.14 71261315 Products Solutions Services Operating Instructions CYR52 Ultrasonic cleaning Document information Warnings The structure, signal words and safety colors of the signs comply

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

Translation of the Original operating instructions Lifting device Z 70 /...

Translation of the Original operating instructions Lifting device Z 70 /... Translation of the Original operating instructions Lifting device Z 70 /... Content 1. Lifting device / Correct use according to regulations 2. Basic principles 3. General information 4. Special remarks

More information

Operating manual. Custom made gearboxes

Operating manual. Custom made gearboxes Operating manual Custom made gearboxes DSS-Nr. 100389549 DSS-Rev. 001 Datum 16.01.2018 Contents Contents 1 General information 3 1.1 Using the operating manual 3 1.2 Warnings in this operating manual 4

More information

Printed: Doc-Nr: PUB / / 000 / 00

Printed: Doc-Nr: PUB / / 000 / 00 ORIGINAL OPERATING INSTRUCTIONS Hilti HTE-P 33 dispenser It is essential that the operating instructions are read before the tool is operated for the first time. Always keep these operating instructions

More information

3 TONNE TROLLEY JACK

3 TONNE TROLLEY JACK 3 TONNE TROLLEY JACK 16407 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any subsequent

More information

These installation and maintenance instructions must be read in full and completely understood before the installation!

These installation and maintenance instructions must be read in full and completely understood before the installation! These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions

More information

Original Operating Manual

Original Operating Manual matev GmbH Nürnberger Str. 50 90579 Langenzenn T +49 (0) 9101 9087-0 F +49 (0) 9101 9087-20 info@matev.eu www.matev.eu Original Operating Manual Snow blade SRM-FB 120 CD Angle adjustment mechanical Version

More information

TRIC A On-Roof Installation for EURO- Collectors*

TRIC A On-Roof Installation for EURO- Collectors* INSTALLATION INSTRUCTIONS TRIC A On-Roof Installation for EURO- Collectors* Fig. 1 Vertical and horizontal on-roof (roof parallel) installation examples Content 1 General Safety Notes. Horizontal Installation.

More information

Instruction Manual. Sewage lifting station compli 300

Instruction Manual. Sewage lifting station compli 300 Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803

More information

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019 Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 DE-74363 Güglingen Telefon: +49(0)7135-102-0 Service: +49(0)7135-102-211 Telefax: +49(0)7135-102-147 E-Mail:

More information

Mini slide EGSC-BS-KF. Operating instructions b [ ]

Mini slide EGSC-BS-KF. Operating instructions b [ ] Mini slide EGSC-BS-KF en Operating instructions 8081968 2017-11b [8081970] Translation of the original instructions EGSC-BS-KF-EN Identification of hazards and instructions on how to prevent them: Danger

More information

Toothed belt axis ELGC-TB-KF. Operating instruction [ ]

Toothed belt axis ELGC-TB-KF. Operating instruction [ ] Toothed belt axis ELGC-TB-KF en Operating instruction 8068220 2017-02 [8068222] Original instructions Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which can

More information

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm² Type 3271 and Type 3277 Pneumatic Actuators Actuator areas: 175v2, 350v2, and 750v2 cm² Translation of original instructions Type 3271 (left) and Type 3277 (right) Pneumatic Actuators Mounting and Operating

More information

SAFETY PRODUCTS. ASK-Series Safety Mat Product Manual

SAFETY PRODUCTS. ASK-Series Safety Mat Product Manual SAFETY PRODUCTS ASK-Series Safety Mat Product Manual 2TLC010047M0201_D ORIGINAL INSTRUCTIONS Read and understand this document Please read and understand this document before using the products. Please

More information

ASSEMBLY AND OPERATING MANUAL LTW PIPE GRAB TYPE GZ 5,0 t

ASSEMBLY AND OPERATING MANUAL LTW PIPE GRAB TYPE GZ 5,0 t manufacturer: LTW Tiefbauvertriebs GmbH Holter Weg 11 D 41836 Hückelhoven-Brachelen phone: +49 (0) 24 62 / 2009 0 fax: +49 (0) 24 62 / 2009 15 e-mail: info@ltw-verbau.de homepage: http:\ \ www.ltw-shoring.com

More information

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 ) Installation, Operating & Maintenance Instructions UHV gate valve with pneumatic actuator Series 108 DN 63 200 mm (I. D. 2½ 8 ) This manual is valid for the following product ordering numbers: 108.. -.

More information

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution Medium Voltage Distribution PIX Withdrawable Voltage Transformer Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual Nr. Edition 11/2011 www.schneider-electric.com Schneider

More information

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION Specifications Outer Dimensions Inner Dimensions Lockbox Inner Dimensions Panel Features Includes 21 W x 15 D x 59 H 20-1/2 W x 12 D x 49-1/2 H 20-1/2 W x 11 D x 7-5/8 H Dual Security System for Keyed

More information

RO Automatic trailer coupling. Repair instructions. 5KPVM02000 Towing Hitch Automatic Rockinger RO244A

RO Automatic trailer coupling. Repair instructions. 5KPVM02000 Towing Hitch Automatic Rockinger RO244A utomatic trailer coupling Repair instructions 5KPVM02000 Towing Hitch utomatic Rockinger RO244 5KPVM02010 Towing Hitch utomatic Rockinger foot operated RO244L Contents 1 General Validity and application

More information

AUTOMATE Li-ion Solar Charging Power Panel

AUTOMATE Li-ion Solar Charging Power Panel AUTOMATE Li-ion Solar Charging Power Panel SOLAR POWERED AUTOMATE Li-ion Solar charging power panel provides supplemental power to all Li-ion wirefree motors or rechargeable battery packs. The monosilicon/crystal

More information

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10. 27 Elster GmbH Edition.7 Translation from the German 344297 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve Contents Solenoid valve... Contents... Safety....

More information

LOG CHOP. Hydraulic Wood Guillotine. Owners Illustrated Instruction Book & Parts List

LOG CHOP. Hydraulic Wood Guillotine. Owners Illustrated Instruction Book & Parts List LOG CHOP Hydraulic Wood Guillotine Owners Illustrated Instruction Book & Parts List Grovebury Road, Leighton Buzzard, Bedfordshire. LU7 4UX. UK. Tel:01525 375157. Fax:01525 385222. Email: enquires@brownsagricultural.co.uk

More information

Enelion Vertica. Installation manual. 22 kw. for the specialists

Enelion Vertica. Installation manual. 22 kw. for the specialists Enelion Vertica kw Installation manual for the specialists ver..6 Enelion 05.07 Enelion VERTICA General notes At various points in this manual you will see notes and precautionary warnings regarding possible

More information

ExitSafe. Operating instructions Retain for future reference _EN_1118

ExitSafe. Operating instructions Retain for future reference _EN_1118 ExitSafe 283880001 Operating instructions Retain for future reference. 181234601_EN_1118 Translation from the original German version. All other documents in different languages are translations of the

More information

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of

More information

Porte 150 Users Manual Swing Gate Opener 24V DC

Porte 150 Users Manual Swing Gate Opener 24V DC Porte 150 Users Manual Swing Gate Opener 24V DC for residential use only Signal Light Push-button Control Box 14 Contents 1. Important Safety Information 2. Product Description and Application 2.1 Application

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI Type FSO, FSO-GR, FS, HPI Hatschekstr.36 69126 Heidelberg Deutschland Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 23.08.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\M1124E_0_FSO_FSO-GR_FS_HPI.docx

More information

OPERATING INSTRUCTIONS. Operating Instructions

OPERATING INSTRUCTIONS. Operating Instructions OPERATING INSTRUCTIONS Operating Instructions Version S-12.1-2010 2 Congratulations on the purchase of your new L-Tec Outdoorlift from L-TEC-Swiss AG. Your L-Tec Outdoorlift has been developed to offer

More information

Northern Sales & Distribution Centre

Northern Sales & Distribution Centre User Manual Industrial Door Northern Sales & Distribution Centre The Door Centre, Discovery Park, Crossley Road, Stockport, SK4 5BW /indupart /indupart /indupart /company/indupart-ltd Foreword This user

More information

CENTAFLEX-K Assembly and operating instructions 014K S... M EN Rev. 1

CENTAFLEX-K Assembly and operating instructions 014K S... M EN Rev. 1 Assembly and operating instructions Contents 1 General remarks... 5 2 Safety... 6 2.1 Qualification of deployed personnel... 6 2.2 Warning notes... 6 2.2.1 Signal words... 6 2.2.2 Symbols... 7 2.3 Application

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL BACK HINTEN en ORIGINAL INSTALLATION AND OPERATING MANUAL Garage door operator S 9060 base+ S 9080 base+ Space for warranty label Dear customer, congratulations on your purchase of a product of SOMMER

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend: General technical data: 1.) Anodised aluminium housing with a connecting rod made of aluminium (in the case of motor types G..B, G..C, G..D and G..E, the connecting rod is Ø18, for all other motor types

More information

Bowl Feeder BF10 / BF15 Translation of operating and installation instructions

Bowl Feeder BF10 / BF15 Translation of operating and installation instructions Bowl Feeder BF10 / BF15 Translation of operating and installation instructions Copyright by Afag GmbH This operation instruction applies to: Bowl feeder right 12 Bowl feeder left 12 Type Order number BF10

More information

Mechanical Operating Instructions

Mechanical Operating Instructions Mechanical Operating Instructions SE 5.24 WS / SE 5.24 51172095 / 04.2006 Bau muster Zertifizierung geprüft EN 13241-1 OPERATING INSTRUCTIONS 52210111 consisting of: M : Mechanical Operating Instructions

More information

s_enn Exterior Stainless Steel Shading System by Draper

s_enn Exterior Stainless Steel Shading System by Draper Installation Instructions s_enn Exterior Stainless Steel Shading System by Draper Caution 1 Never push the bottom rail of the system up by hand. This can cause irreparable damage. Access equipment must

More information

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 3009/16 en Ed.02.2016 Read these Operating Instructions before performing any transportation, installation, commissioning, maintenance or

More information

Bowl feeder BF20 / BF25 / BF30 BF35 / BF40 / BF50

Bowl feeder BF20 / BF25 / BF30 BF35 / BF40 / BF50 Bowl feeder BF20 / BF25 / BF30 BF35 / BF40 / BF50 Translation of operating and installation instructions Copyright by Afag GmbH This operation instruction applies to: Type Order number BF20 BF25 BF30 BF35

More information

FLENDER ARPEX Plate packs with close-fitting bolt connection. ARW-4 Sizes to Assembly instructions An 4239 en 12/2015.

FLENDER ARPEX Plate packs with close-fitting bolt connection. ARW-4 Sizes to Assembly instructions An 4239 en 12/2015. FLENDER ARPEX Plate packs with close-fitting bolt connection ARW-4 Sizes 101-4 to 292-4 Assembly instructions FLENDER couplings FLENDER ARPEX Plate packs with close-fitting bolt connection ARW-4 Sizes

More information

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007 User Manual TABLE MAGNIFIER TL-70 MANUAL DEVELOPED IN GERMANY myhansecontrol.com User-friendly Manual ID: #05007 Contents Overview... 4 Device parts... 5 Scope of delivery/device parts...6 Preface... 7

More information

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use! Operating instructions Pneumatic Crimper AC 100 Date of issue: 05/2010 Keep for future use! SAFETY SAFETY Basic information The basic prerequisite for ensuring safe use and continuous operation of the

More information

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE W.CHRISTIE (INDUSTRIAL) LTD CHRISTIE HOUSE, MEADOWBANK ROAD, ROTHERHAM, SOUTH YORKSHIRE, S61 2NF, UK T: +44(0)1709 550088 F: +44(0)1709 550030 E:

More information

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04)

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04) INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS 300 6720613720-00.1 SD UK/IE CONTENTS Contents Contents 2 1 Safety instructions and explanation of symbols 5 1.1 General safety instructions

More information

Original Operating Manual

Original Operating Manual matev GmbH Nürnberger Str. 50 90579 Langenzenn T +49 (0) 9101 9087-0 F +49 (0) 9101 9087-20 info@matev.eu www.matev.eu Original Operating Manual Front Power System und Front PTO shaft FPS- JD X 950 R for

More information

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only Signal Light Push-button Control Box Gate 2 Gate 1 Contents 1. Important Safety Information 2. Product Description and Application

More information

Original operating manual

Original operating manual matev GmbH Nürnberger Str. 50 90579 Langenzenn T +49 9101 9087-0 F +49 9101 9087-20 info@matev.eu www.matev.eu Original operating manual Engine PTO Shaft FPS-PTO JD-3R for John Deere, type 3033R, 3038R,

More information

Operating Instructions for Roll-Up Door Operators / MDF

Operating Instructions for Roll-Up Door Operators / MDF Operating Instructions for Roll-Up Door Operators / MDF GB Roll-Up Door Operator / MDF / Rev. 0.0 1 1. Contents 3. General safety instructions 1. Contents 2 2. Key to symbols 2 3. General safety instructions

More information

SECTION 14: AERIAL LIFT PROGRAM

SECTION 14: AERIAL LIFT PROGRAM SECTION 14: AERIAL LIFT PROGRAM Fisher Auto Parts is committed to promoting a safe and healthy environment for all employees and customers. Protection from accidental loss of any resources, especially

More information

Spindle axis ELGC-BS-KF. Operating instructions [ ]

Spindle axis ELGC-BS-KF. Operating instructions [ ] Spindle axis ELGC-BS-KF en Operating instructions 8067243 2017-01 [8067245] Original instructions Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which can lead

More information

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR The EU Toy Directive was revised in order to take into account the new technological developments and increasing child safety requirements.

More information

MC500R HYDRAULIC LIFT MANUAL

MC500R HYDRAULIC LIFT MANUAL MANUAL K&L SUPPLY CO., INC 1040 Richard Avenue Santa Clara, CA USA 95050 TEL: 1-800-727-6767 FAX: 1-408-727-4842 Website: www.klsupply.com K&L SUPPLY CO., INC developed this document for its Licensees

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

Bowl feeder WV401-1 / Translation of operating and installation instructions

Bowl feeder WV401-1 / Translation of operating and installation instructions Bowl feeder WV401-1 / 402-1 Translation of operating and installation instructions Copyright by Afag GmbH This operation instruction applies to: Bowl feeder WV401-1 Bowl feeder WV402-1 Type 230 V / 50

More information

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Turbocharger / VTR..0, VTR..1 Original assembly instructions English Assembly Instructions Turbocharger / VTR..0, VTR..1 Original assembly instructions English This document is valid for the VTR..0/..1 series: VTR160, VTR200, VTR250, VTR320, VTR400 VTR161, VTR201, VTR251,

More information

Explosion protected terminal boxes type, GHG 72.

Explosion protected terminal boxes type, GHG 72. 1 Technical data 1.1 Plastic terminal boxes GHG 721... ATX type examination certificate BVS 13 ATX 013 X Marking acc. to 94/9/G and standard ATX x (d e mb) II T5* -55 T amb +55 Gb x (d e mb) II T6* -55

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Installation, Operating and Maintenance Instructions Retractable Door / Art.-Nr.:

Installation, Operating and Maintenance Instructions Retractable Door / Art.-Nr.: Installation, Operating and Maintenance Instructions Retractable Door 06.2008 / Art.-Nr.: 1 818 024 ENGLISH CONTENTS PAGE 1 SAFETY REQUIREMENTS 3 1.1 Symbols and key words used 3 1.2 Designated use 3 1.3

More information

SCOPELITE TIMING LIGHT OPERATING MANUAL

SCOPELITE TIMING LIGHT OPERATING MANUAL SCOPELITE TIMING LIGHT OPERATING MANUAL MOTORTECH Tools & Test Equipment for Ignition Systems P/N 01.10.020-EN Rev. 11/2015 Copyright Copyright 2015 MOTORTECH GmbH. All rights reserved. Distribution and

More information

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D. Installation, Operating & Maintenance Instructions HV gate valve with pneumatic actuator Series 110 DN 250 320 mm (I. D. 10" 12") This manual is valid for the following product ordering numbers: 11048-.

More information

Cordless Rechargeable Saw Instructions for Use

Cordless Rechargeable Saw Instructions for Use Technical data Voltage: DC 10.8V Weight: 1.25Kg Stroke rate: 0-2100/min Stroke: 15mm Cutting capacity: max diameter in wood 80mm / in soft metal 7mm Charging time: Between 5.0-5.5 Hours Battery: 1.3Ah

More information