UWT Lot. Table of contents. Continuous level measuring system SLS 3000 Technical information / Instruction manual. Page

Size: px
Start display at page:

Download "UWT Lot. Table of contents. Continuous level measuring system SLS 3000 Technical information / Instruction manual. Page"

Transcription

1 Table of contents 1 Page Introduction G Function / Approvals G Technical data G Electrical connection G Signal description G Parameter adjustment G Commissioning, Mounting, Safety instructions G Interface measurement with rope G Error code G Maintenance, Service interval G Rope change G1 Tape change G1 Remarks for use in Hazardous Locations G1 Subject to technical change. All dimensions in mm (inches). All units in this information are CE-certifi ed. We assume no liability for typing errors. Different variations to those specifi ed are possible. Please contact our technical consultants. gi0 page G 1

2 1 Introduction / Function / Approvals Introduction Function The UWT-LOT is an electromechanic level measuring instrument for continuous measuring of levels heights or volumes in hoppers, silos or tanks. It is used for monitoring the level in applications such as - powders - small grain bulk goods - coarse grain bulk goods Features - Suitable for most types of bulk goods - Resistant to: Dielectricity and conductivity of the bulk good Dust in the silo Changes in moisture of the product Products that are prone to sticking - No mechanical loading on the silo roof, the sensor weight only comes into contact with the surface of the material. - Easy installation and commissioning - High-tech measurement, easy to understand - Very accurate measurement - Output 0/-0mA - Range of measurement Rope version 0m (0ft) (on request up to 0m (0ft) possible) Tape version m (ft), Overall height of the silo m 0ft) - Approval for use in Hazardous Areas category 1/ D (zone 0/1) - Micro processor controlled measurement with intelligent monitoring - Internal tape cleaner for difficult materials - Different sensor weights, suitable for every application - Robust die cast housing, protection class IP UWT - LOT level measurement systems have withstood the test of time in various industries such as - Chemical industries - Food industry - Building materials industry - Plastics industry The UWT - LOT is mounted on the top of the silo. A sensor weight is wound down into the silo. It is mounted at the end of a rope or tape which is wound on a motor driven roller. Upon contact with material, the motor changes the winding direction and the sensor weight is wound back to the upper stop position. The unit is divided into two independently sealed chambers (tape chamber and electronic chamber). Only the tape chamber is in contact with the inside of the silo during measurement. If the sensor weight is in the upper stop position, it seals the opening between the unit and the silo. Pulses are generated during downward movement and the number of pulses can be processed directly by - a PLC (Programmable logic controller) or - a counter (see chapter "Display / Evaluation"). 0/-0mA output: The pulses are internally converted into an analogue current signal. The current signal can be adjusted according to the application which means that a volumetric signal based on the silo geometry is possible. The current signal is updated, when the sensor weight cimes into contact with the material. The measurement results from an external signal (contact or V DC). For automatic starting there is an integrated timer. The measurement is controlled by a microprocessor. A comparison between the distance the weight moves downwards, and the distance the weight moves upwards, is done. When there is a discrepancy a signal output is activated. This guarantees, that the sensor weight is always in the upper stop position. Approvals For the Lot, the approvals for Hazardous Locations (dust explosion) category 1/ D (zone 0/1) based on directive //EG are available. CE EMC EN -A1 General purpose EN -1 page G gi0

3 Technical data Dimensions For detailed dimensions of UWT - LOT see price list (pages P1 - P). fl ange dimensions similar to DN 0 PN1 1 Sensor weight must not go into the socket! The socket pipe prevents the sensor weight from colliding with the socket edges during upward movement of the weight. The lifetime of the rope is increased, due to less loading on the rope. Version with large socket pipe is available. Dimensions silo fl ange Socket Socket pipe Sensor weight Folding cover sensor weight If the sensor weight is used for measuring very light and loose bulk material, there is a risk that it could descend into the product. This can be prevented by using the folding cover which has a large surface area. The folding cover can be folded to fi t through the mounting socket DN0. Pin for sensor weight The sensor weight can be equipped with a pin Ømm (Ø0, ), which prevents the sensor weight from sliding on the bulk material. gi0 page G

4 1 Technical data Mechanical data Housing: Aluminium RAL 0 gentian blue Flange : black Protection class: IP according to EN 0 Process connection: Overall weight: Measuring rope: Measuring tape: Flange based on DN 0 PN1 Aluminium approx. 1kg (.Ibs) Stainless steel ø1mm (ø0.0 ) 1.01 (1) Stainless steel x0.mm (0. x0.00 ) 1. (01) Measuring interval Accuracy of measurement: Counting pulse: Connection diagram: cm (. ) / pulse (Option: 1cm (0. ) / pulse) Pulse output; 1 pulse (version with cm (. ) pulse) pulses (version with 1cm (0. ) / pulse) Current output: 1% Count: 0.1s ON; s OFF; Reset: 0.s Inside of the lid, datasheet Measuring range: Measuring speed: Sensor weight: max. 0m (0ft) Rope version max. m (ft) Tape version (for max. overall height of silo m (0ft) approx. 0. m/s (0.ft/sec) average (upward and downward movement) 1kg (.Ibs) Rope version 1.kg (.0Ibs) Tape version Sensor weight material: PVC or PA or 1.01 (0) Folding cover made from PET (canvas) Deviation of vertical mounting: max. off the vertical Pressure connection: Electrical data Power supply: Installed load: Quick coupling incl. opposite part for hose diameter mm (0. ); max. operating pressure 0.bar (.psi) 0V 0-0Hz V 0-0Hz both voltages +% / -1% 10VA Connection terminal: max..mm (AWG 1) Protection class: I Heating: Thermostat controlled 0V, 0W; Signal output: Operating conditions Silo pressure: Process temperature: Ambient temperature: Minimum time between measuring starts: rope/tape operating time: Upper stop position / Malfunction Floating relay contact max. 0V AC, A, 00VA bar (-...+.psi) - C..+0 C ( F) optional - C..+0 C ( F) - C.. +0 C (-0 C (- F) with ATEX 1/D) measuring height m (1.ft )-> min measuring height m (.ft) -> min measuring height 0m (.ft) -> min measuring height 0m (.ft) -> 1min see page G Cable entry: Signal output: pcs. Mx1. +1 pc. blind plug for cable diameter -1 mm ( ) pcs. NPT 1/ conduit connection pcs. NPT / conduit connection counting pulse and reset pulse fl oating relay contact max. 0V AC, A, 00VA fl oating current output 0/ - 0mA, ±0.1mA max. load 00Ω page G gi0

5 Electrical connection 1 Counting pulse Reset pulse Malfunction (opens when malfunction) Upper top position (closes when the sensor weight is at the top) internal connection heating Supply voltage Current output 0/-0mA fl oating active Start of measurement and measurement interruption when fi lling internal connection motor max 0V A 00VA Timing of counting pulse Start Reset max 0V A 00VA Counting pulse max A 0V or V /0-0Hz Observe supply voltage on type plate max 00Ω Connection factory provided Start contact Pulse 0...sec Start +V Pulse 0...sec alternative Measurement interruption in case of fi lling (e.g. contact at the fi lling coupling) Remove factory provided connection at terminal and Counting pulse output version 1cm (0. ) pulse Counting pulse Reset pulse Electrical connection version ATEX 1/D For use in Hazardous Locations (dust explosion), category 1/ D the applicable installation regulations (VDE 01) must be observed. Electronic switch Relay contact external fuse max. 1A Timing of counting pulse Start Reset max 0V 0.A DC or AC Counting pulse External equipotential bonding terminal, connect to equpotential bonding of the plant gi0 page G

6 1 Signal description Terminal connections The following supply lines are required: Power supply x 1.mm² (AWG 1) (max..mm² (AWG 1)) for N, L and PE provide fuse (max. A) Start of measurement x 1,mm² (AWG 1) (max.,mm² (AWG 1)) Measurement interruption in case x 1.mm² (AWG 1) of filling: (max..mm² (AWG 1)) Evaluation counting x 1.mm² (AWG 1) and reset pulse: (max..mm² (AWG 1)) Evaluation current x 1.mm² (AWG 1) signal 0/-0mA: (max..mm² (AWG 1)) Relay output,upper stop position max,mm² (AWG 1) and malfunction Signal description Measurement start: Terminal and via fl oating contact. or Terminal and via V DC voltage (current consumption approx. ma, observe the polarity) Duration of starting signal: 0. to s Measurement Terminals and interruption in case via fl oating opening contact. of filling: When the terminal und are opened, the sensor weight returns to the upper stop position. By connection to the end switch, the fi lling coupling prevents the burying of the sensor weight. Counting pulse: Terminal and The counting pulse communicates the measured value to the connected evaluation device During the downward movement of the sensor weight, this pulse is generated every cm (or 0.ft) (option 1cm). Reset pulse: Terminal and After start of measurement, a reset pulse is given about 0.s later. It resets the connected evaluation device (counter/ PLC,...). Current signal Terminal (+) and (-) output: The current signal is a measure for the level (application adjustable). The current signal is updated, when the sensor weight touches the bulk good and is updated. Upper stop Terminal 1 and 1 position This signal allows the user to determine (Option) whether the measurement has come to its end. In this case the sensor weight is in its upper stop position, terminals 1 and 1 are linked. Malfunction: Terminal 1 and 1 (Option) In case of a recognized failure (or lack of supply voltage) the contact will be opened. Description of the error reports, see page G. The malfunction signal output can prevent a torn-off sensor weight from falling into the material. When the signal "Malfunction" is given, the device must always be checked on site. page G gi0

7 Parameter adjustment not active when malfunction button jumps to next adjustment item 1 Counting pulse Reset pulse Operation/ malfunction Upper stop position DISPLAY RUN button - jumps to measurement display during parameters adjustment - starts measurement - cancels an error code on the display LEDs Buttons RUN button increases the value to be adjusted - button decreases the value to be adjusted Cone height C Air distance A 0% max. move distance M 0% Siloheight H Sensor weight Rope Version Tape PVC 0mm (. ) 0mm (. ) PVC ATEX 1/D 00mm (. ) 00mm (. ) PA 0mm (1. ) mm (. ) PA ATEX 1/D 00mm (. ) 00mm (. ) Folding cover 00mm (1. ) 0mm (.1 ) Folding cover TEX 1/D 0mm (. ) 0mm (. ) Stainless steel 0mm (. ) 0mm (1.1 ) Spider stainless steel 0mm (.0 ) 0mm (1. ) Ensure the sensor weight can move down at least 00mm (. ) The maximum move distance ensures that the weight does not enter for example agitators. Measurement value: 0,00m (0,0 ) 1> max.move distance M: RUN Measurement starts; display shows actual measurement distance 0..0m (0..0ft) (1m (1ft)) * 0..m (0..ft) ** Note: If the maximum move distance M is adjusted lower than the silo height S, the measured value is always more than 0%. > Silo height H: 0..0m (0..0ft) (0m (0ft)) * 0..m (0..0ft) ** When using of the digital pulse output (terminal //, see page G) the parameters silo height H, air distance A and cone height C have no infl uence on the measurement value. > Air distance A: > Cone height C: 0..0m (0..0ft) (0m (0ft)) * 0..m (0..0ft) ** 0..0m (0..0ft) (0m (0ft)) * 0..m (0..0ft) ** Adjustment of the cone height C: C =0 Current signal output referring to material level C >0 Current signal output referring to material volume Store changes? Yes / No* * Factory-provided **Values for tape version gi0 page G

8 1 Parameter adjustment Advanced parameter adjustment (only when necessary) The following parameters can be adjusted when required: Measurement value: 0.00m (O.00") A> Software version B> Current output mode C> Current at error D> Timer E> Running mode F> Manual control RUN -0 ma* 0-0 ma 0- ma 0-0 ma 0 ma* ma 0 ma remains 0.1h...h off normal* short upwards downwards Store all changes? Yes / No* * Factory provided push + and button together for 1sec Measurement starts: Display shows actual moving distance 0% 0% Setting -0 ma 0-0 ma 0- ma 0-0 ma Current output at level 0% 0% ma 0 ma 0 ma 0 ma In case of malfunction the current output returns to the adjusted value. 0 ma 0 ma Timer Automatic start of measurement with timer function. Timing interval between two measurements can be adjusted. The timer will be started: - if the sensor weight is at the upper stop position after a measurement. - after external measurement start terminal // - after linking of the terminals / (measurement interruption when fi lling) Position off causes no automatic measurement start. For automatic measurement at a predetermined time of day, a start unit connected to terminals // is necessary. To avoid needless wear and tear, the unit should not be started more than necessary. Running mode ma 0 ma Adjustment normal The sensor weight returns to the upper stop polition after every mesurement. Adjustment short (Only possible in case of use of the 0/-0mA output). The sensor weight stops one meter above material level after it has touched the material. This reduces the wear and the measurement time. Every 0 measurements the sensor weight moves back to the upper stop position to adjust the measurement value. Then it moves back to the position it was before. ATTENTION running mode short 1. To avoid the burying of the sensor weight during the fi lling of the silo, the function measurement interrupt in case of fi lling (terminals /, see page G) must be used. Before the fi lling starts, the sensor weight must be in the upper stop position.. The sensor weight must not hang in the fl ow of incoming material. Manual control Push + button: The motor moves the sensor weight upwards while the button is pushed. Push - button: The motor moves the sensor weight downwards while the button is pushed. CAUTION: Avoid the sensor weight reaching the outlet position of the silo. page G gi0

9 Safety instructions / Mounting Safety instructions Mounting 1 - Installation, maintenance and commissioning must be carried out only by qualifi ed technical personnel. - For terminal connection of the device, the local regulations or VDE00 (Regulations of German electrotechnical Engineers) must be observed. - Use a fuse for the supply voltage (max. A). - Provide protection for relay contacts and output transistors to protect the device against inductive load surges. - Compare the supply voltage applied with the specifi cations given on the name plate before switching the device on. - Make sure that not more than mm (0.1 ) of the pigtails are bared (danger of contact with live parts). - Make sure that the boots for protecting cable terminations are not longer than mm (0.1 ) (danger of contact with live parts). - Make sure that the screwed cable gland safely seals the cable and that it is tight (danger of water intrusion). - A voltage-disconnecting switch must be provided near the device. - In the case of a defect, the distribution voltage must automatically be cut off by a RCCB protection switch so as to protect the user of the device from indirect contact with dangerous electric tensions. - In the case of non-qualifi ed maintenance or handling, the safety of the device cannot be guaranteed. - Switch off the supply voltage before opening the device. - Before opening the lid ensure, that no dust deposits or clouds are present. The unit is mounted vertically with the fl ange on the silo. Avoid the sensor weight catching on the socket which could damage the rope. The mounting position must be chosen so: - built ups that might fall down so not damage the sensor weight or the rope. Ensure proper distance from silo wall. - fi lling of the silo might cover the sensor weight with material (prevent measuring during fi lling or observe proper distance to infeed). - upward and downward movement of the sensor weight must not be obstructed, even if the weight oscillates; observe proper distance to stanchions and built-in fi ttings The electrical connections are made in accordance with the connection diagram. Make sure, that the cable in the screwed cable gland is sealed tightly. Do up both lids of the housing tightly, to prevent water enterint the housing. When the unit is used outdoors, use of the weather protection cover is recommended to protect the unit against moisture and temperature extremes. There must be at least 00mm (. ) space for the sensor weight to move down in case of a full silo. Observe the lower edge of the sensor weight at "upper stop position" (dimensions see page G). Special safety instructions for the use in hazardous areas (dust explosion) at 1/ D (zone 0/1) see page G1. Commissioning Warning: In the case of non-qualified maintenance or handling, the safety of the device cannot be guaranteed. 1. Connect the unit with supply voltage, evaluation units and starting units (see page G).. Cable conduit fi ttings, which are not used, must be sealed with a closing element.. Compare supply voltage and frequency with the specifi cations on the type plate.. Turn on the supply voltage. The sensor weight will move into the upper steop position automatically.. Adjust the parameters (see pages G and G).. The unit is now ready for use. Measuring can begin. Socket Sensorweight Cornices Distance gi0 page G

10 1 Interface measurement with the rope version Function It is possible to measure solid matter in water (interface measurement) usch as mud, sand, sediment etc using the. This is made possible by using a special weight that can be adjusted to the required weight for the interface. Additionally an adjustment screw on the underside of the housing is for fi ne tuning. Together these two adjustments mean that the can be set to the exact level of the interface. The sensor weight has been specially developed for interface applications and has a number of metal and plastic discs which can be inserted into the core of the weight, so that the weight sits on the interface level. The rope is plastic coated, to prevent corrosion. All parts of the SLS that come into contact with the material are either made of stainless steel or are specially laquered. Adjustment 1. Coarse adjustment After mounting and wiring of the, the instrument, the sensor weight must be lowered into the liquied in manual mode (see page G) The weight must not fl oat. This can be checked mechanically by looking at the pulley arm. If the weight is fl oats when it reaches the liquid, then the pulley arm will move briefl y upwards. The sensor weight then needs to be made heavier by replacing one or more of the plastic discs with stainless steel discs. This is achieved by unscrewing the lid of the sensor weight and swopping the plastic discs with stainless steel discs. It is important that the sensor weight is completely fi lled with discs, otherwise the trapped air could provide too much buoyancy. After the course adjustment, then the fi ne adjustment can be carried out. Mechanical chamber Pulley arm sensor weightt stainless steel and plastic discs. Fine adjustment: The fi ne adjustment is made using the screw adjustment on the underside of the housing. The following adjustments can be made (when looking at the bottom of the housing) Folgende Einstellung kann mit Gehäuseansicht von unten durchgeführt werden: o Screw anti clockwise sensor weight becomes more sensitive ie "lighter" o Screw clockwise sensor weight becomes less sensitive ie "heavier" Lid Fine adjustment screw Cable glands page G gi0

11 Error codes Switch off the supply voltage and ensure, that it can not be switched on again, before repairs are completed Error code Possible reason Performance of the device Solutions Error code Error code Internal pulse sensors are not identifi ed by the software Rope/tape break. Motor blocked or broken. The motor stops. When the pulse sensors can be identifi ed again, the sensor weight moves to the upper stop position. The motor stops. This code is displayed: when error code occurs and minutes have elapsed and the sensor weight has not reached the upper stop position. Connect the internal plug for the pulse sensor. Repair the tape break (see page G/G1). Look for the reason of motor blocking. 1 Error code No pulses come from the return pulley. Return pulley moves too heavily. Motor defect. The motor moves the sensor weight upwards, until it reaches the upper stop position. Repair the stiff movement of the return pulley. Change motor. Error code Sensor weight buried or jammed. The motor moves seconds upwards, then it waits for seconds. After that the motor moves shortly downwards and then upwards again. If the sensor weight is still jammed, this cycle repeats times. After that the delay time will be increased to one hour. Release the sensor weight. Check that the sensor weight can move freely. Error code Supply voltage too low. Adjust to correct supply voltage. Error code Sensor weight blocked in "upper stop position" or distance sensor weight < 00mm (. ) The unit tries to start times. If the sensor weight is not able to be release, the error code is displayed. (The signal output indicates no error.) Release sensor weight. Increase the min. moving distance to > 00mm (. ) Error code Service interval See chapter "service interval" page G By pushing the RUN button an error code shown on the display can be canceled. (not acive when malfunction) Counting pule LEDs Reset pulse Operation/ malfunction Upper stop position Fuse F1.A Internal plug for pulse sensors DISPLAY Control of the measurement The device compares the distance of downwards movement of the sensor weight (until it reaches the surface of the bulk good) with the distance of upwards movement, until it reaches the upper stop position. When the values are different, this is an indication of a buried or jammed sensor weight. Furthermore, the pulses generated by the return pulley during the measurement are monitored. When there are missing or too irregular pulses this indicates that the return pulley moves too heavily or that the motor is blocked. Returnpulley Upper stop position" Sensor weight gi0 page G

12 1 Maintenance / Service interval Maintenance The UWT- LOT measuring device features a high degree of functional reliability and it requires virtually no maintenance during normal operation. However, it is recommended that the following checks arer regularly carried out. Open the rope-/tape chamber lid. Remove any excess material in the rope-/tape chamber. Check the rope-/tape for wear and tear. Do up the rope-/tape chamber lid tightly. If the rope-/tape is worn or torn, it must be changed (possibly shortened). Available spare parts are: - loose rope - rope-/tape roller (with 0m (.ft) rope or m (.ft) tape) - mounting set for sensor weight - sensor weights Rope/tape chamber Rope/tape roller Rope/ tape Sensor weight Service interval (Error code ) Error code is created automatically after the following number of measurements. Rope version: Tape version: To further guarantee faultless performance, it is strongly recommended to change the rope/tape (see pages G or G1). Rope/Tape durability Number of measurements Rope version approx Tape version approx These values refer to lifetime tests without material infl uence. The sensor weight meets an incline surface, so that an oscillating movement of the sensor weight is caused. Based on these values, the following graph has been produced. When the message appears, the following will occur: - The malfunction relay (terminal 1/1) indicates error. - The message Error appears on the display. Following situation stays, until the message is cancelled with the RUN -button: - Measurements can be resumed. - The malfunction relay (terminal 1/1) still indicates error. - The internal timer does not work. - The message Error remains on the display. - The internal counter, which counts the number of measurements, does not work. When the message is canceled with the RUN -button, the next message will appear after another (0 000) measurements. Operating time in years Rope version Tape version Measurements per day page G gi0

13 Rope change NOTE: Only the manufacturer is allowed to repair devices with ATEX-approval for use in Hazardous Locations (dust explosion) cat. 1/ D (zone 0/1). Switch off power supply, ensure that power cannot be accidentally restored/switched back on. Remove the device from the silo. Open the lid to the rope chamber. Remove the rope roller ( screws). Wind up a new rope or mount a new cable roller (observe the direction of winding), leave about 1. m (.0 ) of rope unwound. Mount the sensor weight in accordance with the drawing. Rope chamber Rope roller 1 Feed sensor weight into the socket, mount the device on the silo again. Check the feeding of the rope inside the rope chamber. Do up the rope chamber lid tightly. Switch on power supply. The sensor weight moves automatically at the upper stop position. The device is now ready for use. Measuring can begin. Rope Sensor weight A new software adjustment is not necessary. Rope Sensor weight Hose shrink Tubing Knot the rope tight Lighter or hot air gi0 page G 1

14 1 Tape change NOTE: Only the manufacturer is allowed to repair devices with ATEX-approval for use in hazardous locations (dust explosion) cat. 1/ D (zone 0/1). Take care when working with the tape. Danger of injury caused by sharp edges. Tape chamber Tape roller Do not kink the tape. Switch off power supply, ensure that power cannot be accidentally restored/ switched back on. Tape feeding bolts Remove the device from the silo. Open the lid to the tape chamber. Remove the tape roller ( screws). Mount a new tape roller (observe the direction of winding), leave about 1. m (.0 ) of tape unwound. Ensure that the tape feeds inside the tape feeding bolts. Remove tape cleaner (including sealing), to feed the tape through the socket pipe. Mount the sensor weight in accordance with the drawing. Feed sensor weight into the socket, mount the device on the silo again. Check the feeding of the tape inside the tape chamber. Do up the lid to the tape chamber tightly. Switch on power supply. The sensor weight moves automatically in the upper stop position. Tape Socket pipe Tape cleaner withspring: mounted with screws Sealing Rubber nozzle Cone Screw, nut Spring The tape cleaner must be able to move upwards against the pressure spring The device is now ready for use. Measurements can begin. A new software adjustment is not necessary. tubes tape fi xing parts screws Sensor weight page G 1 gi0

15 Remarks: ATEX Remarks for use in hazardous locations (dust explosions) according to ATEX 1 Zone classifi cation The approval according to ATEX (directive //EC) for the Hazardous Locations (dust explosion) category 1/ D (zone 0/1) determines the following classifi cation: Device category acc. to //EG Useable in zone 1 D 0, 1, D 1, D*) *) when conductive dust, additional requirements. Container wall Zone (Category ) Zone 1 (Category ) Zone 0 (Category 1) outside container inside container General notes Marking Devices with EX approval are marked on the type plate. Process pressure for ATEX Process and ambient temperature The device construction allows process over-pressure up to 0. bar (.psi) (see type plate). These pressures are allowed for test purposes. The defi nition of the ATEX is only valid for a containerover-pressure of between bar ( psi). Outside of these pressures the approval is not valid. The permitted temperature ranges are marked on the type plate. gi0 page G 1

16 1 Remarks: ATEX Maximum surface temperature The following information shows the maximum surface temperature at the warmest part of the unit which could occure dureing failure (according to ATEX defi nition). The data is valid, if it can be guaranteed during installation, that the area shown with the dotted line, has a maximum temperature of 0 C at normal use. Max. Surface Temperature Ambient Temperature in Zone 1 Processtemperature in Zone 0 0 C (1 F) 0 C ( F) 0 C (10 F) 0 C ( F) 0 C ( F) 0 C (1 F) 1 C (0 F) 0 C (10 F) 0 C (1 F) 1 C (0 F) 0 C (1 F) 1 C (0 F) 0 C ( F) 1 C (0 F) 1 C (0 F) 0 C ( F) 0 C ( F) 10 C ( F) 10 C ( F) 10 C ( F) 10 C ( F) C (0 F) C (0 F) 10 C (0 F) 10 C (0 F) 10 C ( F) 10 C ( F) 10 C ( F) 10 C ( F) 10 C ( F) 10 C ( F) 00 C ( F) 00 C ( F) C ( F) C ( F) 0 C ( F) 0 C ( F) Container wall max. 0 C (1 F) Zone 1 Zone 0 Safety instruction for Hazardous Locations For devices used in Hazardous Locations (dust explosion) zone 0/1 the relevant installation regulations must be observed. The requirements of the EN (e. g. regarding dust deposits and temperatures) must be observed WARNING: When using a metal sensor weight or when using a plastic sensor weight, which is not mounted by an additional plastic rope on the metallic rope/tape (and therefore does not have a safe isolation distance between bulk material surface and grounded rope/tape): It must be ensured, that no static discharge can occur when the sensor weight touches the surface of the bulk material. If this can not be safely ensured, the safe use of the unit is NOT possible. The responsibility for this lies with the users. In case of inclarity an assessment from a notifi ed body is necessary. An alternative version with a plastic sensor weight and additional plastic rope can be chosen. When using a conduit system (with NPT thread) instead of a cable gland, the regulations of the country where the unit is installed, must be observed. The conduit must have a tapered thread either NPT 1/ or NPT / in accordance with the unit and ANSI B Unused inlets must be sealed with a metal closing element. A strain relief must be provided for the connection cables. Use only with closed lid. Switch off the supply voltage before opening the device. Before opening the lid, ensure that no dust deposits or clouds are present. Only the manufacturer is allowed to repair devices with ATEX-approval. page G 1 gi0

introduction function electrical connection signal describtion parameter adjustment commissioning, mounting, safety items error codes

introduction function electrical connection signal describtion parameter adjustment commissioning, mounting, safety items error codes list of contents page introduction G1 function G1 technical data G2 - G3 electrical connection G4 signal describtion G5 parameter adjustment G6 - G7 commissioning, mounting, safety items G8 error codes

More information

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/ Series DBOB-Continuous Level Measuring System Bulletin L-DBOB Specifications - Installation and Operating Instructions 7-9/32 [185.00] 5-45/64 [145.00] 8-21/32 [220.00] 5-45/64 [145.00] 10-1/32 [255.00]

More information

Continuous level measuring system NB 4000 Selection list

Continuous level measuring system NB 4000 Selection list Table of contents Page Overview P2 Specification / application P3 P4 Options / Accessories P6 Dimensions / materials P7 Spare parts P9 Electrical installation P11 Subject to change. All dimensions in mm

More information

Continuous Level Measuring System. LevelMax. Instruction Manual

Continuous Level Measuring System. LevelMax. Instruction Manual Continuous Level Measuring System 1 Table of contents Page Safety notes / Technical support Introduction Dimensions and materials Options / Accessories Technical data Mounting Mounting with aiming fl ange

More information

Continuous level measuring system NB 3000 Selection list

Continuous level measuring system NB 3000 Selection list Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------

More information

Continuous level measuring system NB 3000 Selection list. Overview

Continuous level measuring system NB 3000 Selection list. Overview Table of contents Page Overview P2 ------------------------------------------------------------------------------------------------------------------- Specifications P3 -------------------------------------------------------------------------------------------------------------------

More information

Continuous level measuring system. LevelMax. Selection Guide. Overview 2

Continuous level measuring system. LevelMax. Selection Guide. Overview 2 Table of contents Page Overview 2 ------------------------------------------------------------------- Specification / application 3 ------------------------------------------------------------------- 4

More information

Level MONITORING. Continuous Level Measurement ILS

Level MONITORING. Continuous Level Measurement ILS Level MONITORING Continuous Level Measurement ILS Continuous Level Measurement ILS Reliable continuous level MEASUREMENT DEVICES FOR ANY KIND OF BULK SOLIDS STORED IN SILOS AND CONTAINERS A sensor weight,

More information

Kondunivo Table of contents

Kondunivo Table of contents Kondunivo Table of contents Page Introduction G Technical data G Mounting G Electrical connection G Adjustment G Switching logic G Maintenance G Error search G Subject to technical change and price change.

More information

Capanivo Series CN 4000

Capanivo Series CN 4000 Capanivo Series CN 4000 Instruction manual 010516 1 UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de Scope of this instruction

More information

Nivobob 1. Table of contents. Continuous level measuring system NB 4000 Technical information / Instruction manual. Page

Nivobob 1. Table of contents. Continuous level measuring system NB 4000 Technical information / Instruction manual. Page Nivobob 1 Table of contents Page Safety notes / Technical support ------------------------------------------------------------------------------------------------------ Introduction ------------------------------------------------------------------------------------------------------

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3 Operating Instructions Pneumatic Control Valve Low Temperature Type 8026 Series GS3 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 03/2006

More information

Operating Instructions. Angle Seat Control Valve. Type 7020

Operating Instructions. Angle Seat Control Valve. Type 7020 Operating Instructions Angle Seat Control Valve Type 7020 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 02/2006 Manual-7020e.doc Art.-No:

More information

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4 Table of contents Page Specifications 2 Applications 4 ------------------------------------------------------------------------------------------------------------ CN 4020 5 Short extension length ------------------------------------------------------------------------------------------------------------

More information

Table of contents Page Safety notes / Technical support Introduction Technical data Approvals Options Mounting Electrical installation 1 Signal output 1 Sensitivity setting 1 Maintenance 1 Notes for use

More information

DIAMOND POINT VIBRATING PROBES

DIAMOND POINT VIBRATING PROBES DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527

More information

Table of contents Page Safety notes/ Technical support Introduction Technical data Approvals Options/ accessories Mounting Electrical installation 1 Settings 1 Signal output logic 1 Maintenance 1 Notes

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

OPTISWITCH 4000/5000. Vibration level switches for liquids

OPTISWITCH 4000/5000. Vibration level switches for liquids OPTISWITCH 4000/5000 Technical Datasheet Vibration level switches for liquids Operates up to 250 C / 480 F and 64 bar / 925 psi Pump dry-run detection High reliability due to permanent fault monitoring

More information

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0312 Rev B TABLE OF

More information

CVR-625. Compact Vibrating Rod Instruction Manual

CVR-625. Compact Vibrating Rod Instruction Manual CVR-625 Compact Vibrating Rod Instruction Manual BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS

More information

Operating instructions According to Directive 2014/34/EU (ATEX) Annex II p group II, equipment category 1/2D

Operating instructions According to Directive 2014/34/EU (ATEX) Annex II p group II, equipment category 1/2D 1. Introduction Fig.1 MAX. ( Process ) MIN. ( Ambient ) The Rotative Level Control RL-A AD1/2* are used to detect the level of materials such as dust or granules in containers. They are supplied with plastic

More information

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications Table of contents Page Overview Specifications Applications P2 P4 P6 --------------------------------------------------------------------------------------------------------- RN..001 Short extension length

More information

Level limit switch Series RN 3000 / 6000 Selection list

Level limit switch Series RN 3000 / 6000 Selection list Table of contents Page Overview Specifications Applications P2 P4 P6 -------------------------------------------------------------------------------------------------------- RN..001 Short extension length

More information

Level limit switch Series RN 3000 / 6000 Selection list

Level limit switch Series RN 3000 / 6000 Selection list Table of contents Overview 2 Specifications 4 Applications 6 Page -------------------------------------------------------------------------------------------------------- RN..001 8 Short extension length

More information

Level limit switch Series RN 3000 / 6000 Selection list. Overview

Level limit switch Series RN 3000 / 6000 Selection list. Overview Rotonivo Table of contents Page Overview Specifications Applications P2 P4 P6 -------------------------------------------------------------------------------------------------------- RN..00 Short extension

More information

Overview. Specifications. Applications

Overview. Specifications. Applications Vibranivo Level limit switch 1 Series VN 00 / 000 / 000 / 000 Table of content Page Overview P Specifications P Applications P ------------------------------------------------------------------------------------------------------------

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

Level limit switch Series RN 4000 Selection list. Overview / Specification / Applications

Level limit switch Series RN 4000 Selection list. Overview / Specification / Applications Table of contents Page Overview / Specification / Applications P2 ----------------------------------------------------------------------------------------------------------- Selection P3 -----------------------------------------------------------------------------------------------------------

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators Fig. 1 Type 3761 Positioner Mounting and Operating Instructions EB 8386 EN Edition July 2007 Contents Contents Page 1 Design and

More information

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids Technical Information Soliphant T FTM260 Level limit switch Cost-effective vibration limit switch for fine-grained solids Application Soliphant is a rugged level limit switch for use in silos containing

More information

GP Rev a ( ) DCN0533

GP Rev a ( ) DCN0533 TABLE OF CONTENTS 1.0 INTRODUCTION.....3 Function Range of Application Typical Installations 2.0 TECHNICAL DATA.....5 General Dimensions Mechanical Data Electrical Data Operating Conditions 3.0 MOUNTING......8

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

OPERATING INSTRUCTIONS. LEISTER Varimat V Hot Air Automatic Welding Machine

OPERATING INSTRUCTIONS. LEISTER Varimat V Hot Air Automatic Welding Machine GB OPERATING INSTRUCTIONS Hot Air Automatic Welding Machine Please read operating instructions carefully before use and keep for further reference. APPLICATION Automatic Overlap Welding Machine For overlap

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 5868/5869 EN Electric Control Valves Types 3213/5857, 3213/5824, Types 3214/5824, 3214/3374, 3214/3274 with safety function: Types 3213/5825, 3214/5825, 3214/3374, 3214/3274 Pneumatic Control Valves Types 3213/2780-1,

More information

Manual for Inverter system type PCI05

Manual for Inverter system type PCI05 - 1- Manual for Inverter system type PCI05 SAFETY INSTRUCTIONS This manual must be read before installation, use or work on the product. This product contains dangerous voltages that when touched can cause

More information

Positive displacement batch controller

Positive displacement batch controller 8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total

More information

Level Limit Switch soliphant FTM 930/931/932/ Z

Level Limit Switch soliphant FTM 930/931/932/ Z Technical Infmation TI 042F/00/e Level Limit Switch soliphant FTM 930/931/932/ Z F Universal Application with Bulk Materials and Dust Ex Area Application The Soliphant has a wide range of safe applications

More information

FF03. Rotary Blade Level Switch for bulk goods. Level Measurement and Monitoring

FF03. Rotary Blade Level Switch for bulk goods. Level Measurement and Monitoring Level Measurement and Monitoring FF03 Rotary Blade Level Switch for bulk goods For bulk good with grain size up to 150 mm and bulk weight from 0,01 up to more than 2,0 t/ m³ Robust aluminium diecast housing

More information

Level limit switch Series RN 3000 / 6000 Technical information / Instruction manual

Level limit switch Series RN 3000 / 6000 Technical information / Instruction manual Rotonivo 1 Series RN 000 / 000 Table of contents Page Safety notes/ Technical support --------------------------------------------------------------------------------------------------------- Introduction

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document. General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Features and functions Power supply Standard

More information

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX) Operating Instructions VEGASWING 61, 63 with oscillator SW E60N (EX) Contents Contents Safety information... 2 Note Ex area... 2 1 Product description... 3 2 Function and application... 4 2.1 Principle

More information

H-1274 OR-T 200. Battery-hand tool for plastic strapping. Before using the tool, read the operating instructions carefully. 08/07

H-1274 OR-T 200. Battery-hand tool for plastic strapping. Before using the tool, read the operating instructions carefully. 08/07 H- OR-T 00 Battery-hand tool for plastic strapping Before using the tool, read the operating instructions carefully. 08/0 ORGAPACK OR-T 00 Technical data TABLE OF CONTENTS General information Page. Information

More information

Rotary blade level indicators Level limit switches for bulk goods. Accessories

Rotary blade level indicators Level limit switches for bulk goods. Accessories Storm tape Weather protection hood for outdoor use as protection against overheating in the case of strong radiation from the sun. -SH Weather protection hood with storm tape... 8,-- Material PVC, RAL

More information

TOWA SEIDEN INDUSTRIAL CO., LTD.

TOWA SEIDEN INDUSTRIAL CO., LTD. INSTRUCTION MANUAL SOUNDING LEVEL METER MODEL: TLX-120AP/200AP Meanings of indications for safety used in this Instruction Manual are as follows. WARNING: Indicates that improper handling assumes the risk

More information

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Power supply Standard voltages AC: 3-phase

More information

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

NIVOCONT R VIBRATING ROD LEVEL SWITCHES For solids NIVOCONT R VIBRATING ROD LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES O U R P R O F E S S NIVOCONT R VIBRATING ROD LEVEL SWITCHES MAIN FEATURES Extension up

More information

JUMO dtrans p20 DELTA

JUMO dtrans p20 DELTA Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision

More information

Operating Instructions OPTISWITCH 4000 C with transistor output

Operating Instructions OPTISWITCH 4000 C with transistor output Operating Instructions OPTISWITCH 4000 C with transistor output Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbolism used... 3 2 For your safety 2.1 Authorised

More information

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN Pneumatic or Electropneumatic Positioner for Rotary Actuators Type 3761 Fig. 1 Type 3761 Positioner Mounting and Operating Instructions EB 8386 EN Edition June 2004 Contents Contents Page 1 Design and

More information

Soliswitch FTE30. Technical Information

Soliswitch FTE30. Technical Information Technical Information Soliswitch FTE30 Level limit switch Economical paddle limit switch with type-examination certificate to ATEX dust Ex-approval zone 20 Application The universal paddle level limit

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN Globe Valve Type 3241 Fig. 1 Type 3241 Globe Valve Mounting and Operating Instructions EB 8015-1 EN Edition July 2012 Contents Contents Page 1 Design and principle of operation.................... 4 2

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Siemens AG 009 Supplementary electronics for 4-wire connection Design Dimensions (W x H x D) in mm (inch) Electrical connection 80 x 10 x 60 (3.15 x 4.7 x.36) Screw terminals (Pg 13.5 cable inlet)

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z Installation and operating instructions Solar charge controller MPPT 10 A / 20 A EN 1 Contents 1. About these instructions... 3 1.1 Applicability... 3 1.2 Users... 3 1.3 Description of symbols... 3 2.

More information

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23. Pressure Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS23.100 and PGS23.160 k Applications for further approvals see page 7 WIKA data sheet PV 22.02

More information

SolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH

SolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH EN SolidFlow Product Information Monitoring of Solids SWR engineering Messtechnik GmbH Using SolidFlow is a sensor especially developed for measuring the flow rate of solids conveyed in metallic ducts.

More information

Operating Instructions Type MPT 53

Operating Instructions  Type MPT 53 Operating Instructions www.turnstiles.us Type MPT 53 Contents 1. Delivery... 2 2. Safety...3-4 3 Description and operation... 5 4. Technical Data 6 5. oundation...6-9 6. Assembly and installation...10-13

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5

More information

INSTALLATION GUIDE Ultrasonic Sensors Series UX micro

INSTALLATION GUIDE Ultrasonic Sensors Series UX micro INSTALLATION GUIDE Ultrasonic Sensors Series UX micro For further information please see the data sheet at www.waycon.biz/products/ultrasonic-sensors/ FIRST STEPS WayCon Positionsmesstechnik GmbH would

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

DCE 100 Series Dust Filter

DCE 100 Series Dust Filter Installation, Operation and Maintenance Manual DCE 100 Series Dust Filter Publication 2638B (GB) 0702 1419-8000A Donaldson Torit DCE reserve the right to alter design without notice. Freedom from patent

More information

Point level measurement Capacitance switches

Point level measurement Capacitance switches Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.

More information

Operating Instructions Pedestrian Turnstile Type MPT 33

Operating Instructions Pedestrian Turnstile Type MPT 33 Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11

More information

OPTIMASS 3000 Technical Datasheet

OPTIMASS 3000 Technical Datasheet OPTIMASS 3000 Technical Datasheet Sensor for mass flow First choice for low flow applications Certified secondary pressure containment A common footprint for all three sizes, in Hastelloy or Stainless

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

PROCAP Capacitance Level Sensors

PROCAP Capacitance Level Sensors PROCAP Capacitance Simple. Rugged. Reliable. Triple thread screw on/off cover - No more bolts! Unsurpassed sensitivity and stability No interference from RF signals Switch selectable high/low fail-safe

More information

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION SERIES 1000-X OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION Publication S1000X-110 VER0215-1 For information on this product and

More information

Table of contents Series VN 00 / 000 / 000 / 000 Page Safety notes / Technical support G --------------------------------------------------------------------------------------------------------- Introduction

More information

EStrong-series Emergency Stop

EStrong-series Emergency Stop Original instructions EStrong-series Emergency Stop ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand

More information

HS5D Miniature Interlock Switches

HS5D Miniature Interlock Switches Head removal detection for safer performance. Head removal detection function turns OFF the main circuit (-) when the head of the is removed. The is the same size as contact interlock switches (HS5B).

More information

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._ Please read these Installation Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to brake failure, resulting in damage to other parts. Contents:

More information

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting.

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting. evel instruments Siemens AG 2009 Overview Configuration Horizontal mounting (recommended mounting position, particularly for adhesive applications) Vertical mounting with lower density is a compact vibrating

More information

Solenoid Valves Type 3963

Solenoid Valves Type 3963 Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate

More information

H-1465 OR-T 300. Battery-hand tool for plastic strapping. Before using the tool, read the operating instructions carefully. 08/07

H-1465 OR-T 300. Battery-hand tool for plastic strapping. Before using the tool, read the operating instructions carefully. 08/07 H- OR-T 00 Battery-hand tool for plastic strapping Before using the tool, read the operating instructions carefully. 08/0 ORGAPACK OR-T 00 TABLE OF CONTENTS TECHNICAL DATA Technical data General information

More information

LTX RF LEVEL SENSOR. Instruction Manual

LTX RF LEVEL SENSOR. Instruction Manual LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004

More information

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD General information AC 01.2 Actuator controls in SIL version for controlling multi-turn actuators of the SA/SAR.2 type range and part-turn actuators of the SQ/SQR.2 type range. Information on SIL features

More information

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT-161609 Read before commencement of all work! This ignition unit must be mounted in accordance with the applicable

More information

Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch

Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety

More information

Pressure chlorine changeover unit C 7520

Pressure chlorine changeover unit C 7520 BW 2 24 04 / 1 Content 1. Scope of delivery 2. Device description 3. Installation 4. Operation 5. Shutdown 6. Maintenance 7. Troubleshooting 1 Scope of delivery The chlorine gas changeover unit C 7520

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 The single-battery-supplied emergency lamps of the ECOLUX 6608 lighting series are employable as safety lighting

More information

Pressure Transmitters

Pressure Transmitters Transmitters Wetted parts are all made of stainless steel for high resistance to chemicals Stainless steel diaphragm welded with casing No seals and thus low leakage rate even with difficult gases High

More information

Freefall metal detection system Vistus with separator FL

Freefall metal detection system Vistus with separator FL Freefall metal detection system Vistus with separator FL The space-saving model Separator FL benefits For maximum space-saving: the low installation height allows for especially short complete systems

More information

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for

More information

Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)

Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S) Technical Information TI 9F/00/en Level Limit Switch soliphant II FTM 0 (D/S), FTM (D/S), FTM (D/S) Universal vibration limit switch for fine-grained bulk solids Suitable for dust explosion hazardous areas

More information

Factor 2) 160:1 6) /(30) FA10 (FA14) :1 6) /(30) FA10 (FA14) 27 86

Factor 2) 160:1 6) /(30) FA10 (FA14) :1 6) /(30) FA10 (FA14) 27 86 to [ft-ib] Valve Max. valve Valve attachment Gearbox Reduct. torque 1) Modulating torque 4) to [ft-ib] Flange acc. to MSS SP 101 Factor 2) Turns for 90 Gearboxes Input shaft Input mounting fl ange for

More information

GP50 Vibrating Fork Level Switch. Vibrating level switch for powders and granular solids K-TEK Products

GP50 Vibrating Fork Level Switch. Vibrating level switch for powders and granular solids K-TEK Products Operating instruction manual OI/GP50-EN Rev. B GP50 Vibrating Fork Level Switch Vibrating level switch for powders and granular solids K-TEK Products Introduction This operating instruction manual provides

More information

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4DL. Guard Lock Safety-door Switch. Model Number Structure Guard Lock Safety-door Switch Two new types added to series: Mechanical-lock models that lock automatically when the Operation Key is inserted, and solenoid-lock models that lock when voltage is applied

More information

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see Technical data) Page 1/15 JUMO dtrans p20 Process pressure transmitter Brief description The device with the HART interface combines maximum precision with simple operation. It is used to measure the system pressure of

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Level Measurement Point level measurement - Vibrating switches

Level Measurement Point level measurement - Vibrating switches Overview Configuration Horizontal mounting (recommended mounting position, particularly for adhesive applications) Vertical mounting is a compact vibrating level switch for material detection in liquid

More information

PROCAP Capacitance Level Sensors

PROCAP Capacitance Level Sensors PROCAP Capacitance Level Sensors Simple. Rugged. Reliable. Triple thread screw on/off cover - No more bolts! Unsurpassed sensitivity and stability No interference from RF signals Switch selectable high/low