ATLANTES FREEDOM. Household Style Marine Toilet. Model A7, A8 and A9 Manufactured after July 2005)

Size: px
Start display at page:

Download "ATLANTES FREEDOM. Household Style Marine Toilet. Model A7, A8 and A9 Manufactured after July 2005)"

Transcription

1 ATLANTES FREEDOM Household Style Marine Toilet Model A7, A8 and A9 Manufactured after July 2005) THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this product. Equipment damage, injury to personnel or death could result from improper installation. Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment, or injury or death to personnel that may result from improper installation or operation of this product. WARNING: HAZARD OF FLOODING - Always shut off seacocks before leaving the boat unattended. Double clamp all below waterline hose fittings and check frequently for integrity. HAZARD OF SHOCK OR FIRE - Always use recommended fuse, circuit breaker and wire size. A7 and A8 Models with Flush Lever A9 Model with Wall Switch Flush Control Panel INTRODUCTION The Atlantes is Raritan s best electric macerating toilet. All working parts fit inside the one-piece porcelain bowl on Integral Intake Pump models. The powerful centrifugal macerating pump thoroughly breaks down waste in preparation for treatment or holding. Three systems are available: Integral Intake Pump - for above waterline installations only. Remote Intake Pump - for above and below waterline installations. Freshwater Solenoid Valve - for flushing with pressurized fresh water com 1

2 OPERATION Flush Lever The A7 model The A7 model is designed to work as a momentary unit using only microswitches to activate the motors. It is also a fail safe mode for the toilet control in the A8 model. The A8 model The A8 model contains an electronic toilet control which provides timed operation while still having momentary functionality if toilet control is removed. Operation: pull handle forward: Model A8 - starts a timed flush, intake pump starts followed by discharge pump. Model A7 - Hold to add water. push handle backward: In both models runs just the discharge pump for a dry bowl flush. EMPTY BOWL FLUSH FLUSH LEVER POSITIONS Timed FLUSH FILL WATER Pull Handle Push Handle The A9 model The A9 model contains an electronic box and functions with wall mounted flush control. Wall mounted Flush Control NORMAL FLUSH Press Normal Flush - starts a timed flush, intake pump starts followed by discharge pump. WATER SAVER FLUSH Press Water Saver Flush starts a timed flush using half the water of a normal flush EMPTY BOWL FLUSH Press and hold Empty Bowl Flush touch pad until all water is removed from bowl. MOMENTARY FLUSH Press and hold Momentary Flush touch pad to flush bowl momentarily. NOTE: To discontinue a timed flush press and release any button. Wall Mounted Flush Control 2

3 Cleaning Instructions IMPORTANT: Do not use cleaners that contain ammonia, ethyl acetate, phosphoric acid or concentrated chlorine bleach. These may cause damage to the toilet. We recommend using Raritan C.P. (#1PCP22), a bio-enzymatic toilet bowl cleaner. Cleaning In-Line Strainer (Sea Water Models only) 1. Shut off intake seacock. 2. Unscrew bowl. 3. Remove filter. 4. Clean bowl and filter, wipe with a clean dry cloth. 5. Clean gasket and gasket contact surfaces thoroughly. 6. Replace gasket, filter and bowl. 7. Open seacock. 8. Check for leaks. Filter Bowl Unscrew C.P. Clean gasket and gasket contact surfaces thoroughly Tighten MAINTENANCE Refilling Optional Atlantes Deodorant System (ADS) Intake pump models only Using Raritan Concentrate (#CON22) helps keep the bowl clean and lubricates internal parts. Pour 8 oz. (237ml) of concentrate into tank and fill with water. 3

4 WINTERIZING IMPORTANT Improper winter lay up is a major cause of marine toilet failure. Use only nontoxic antifreeze. Flush toilet several times to clear waste from system. Dispose of all antifreeze in accordance with local and federal regulations. Winterize holding tanks, plumbing, treatment systems (MSD s), etc. independently following manufacturer s instructions. Pressurized Freshwater Models Parts Required 1 1/2" (38mm) I.D. piece of discharge hose, approximately 3 (1m) long Two buckets Nontoxic antifreeze approximately 1 quart (1 liter). Steps 1. Close discharge seacock. 2. Shut off intake water at source. 3. Turn off power to unit. 4. Disconnect and drain discharge hose. 5. Disconnect intake hose from intake water source and drain. 6. Connect hose to toilet s discharge and place in other bucket. 7. Pour antifreeze in toilet bowl. 8. Turn on power to unit and flush until antifreeze is removed from bowl and water is drained from solenoid valve and hose. 9. Disconnect power to toilet. Nontoxic Antifreeze Pressurized Freshwater Model Atmospheric Vacuum Breaker Discharge Hose Solenoid Valve Intake Water Source Shut Off Valve Allow water to drain into bucket Integral and Remote Intake Pump Models Parts Required 3/4" (19mm) I.D. piece of intake hose approximately 3 (1m) long. 1 1/2" (38mm) I.D. piece of discharge hose approximately 3 (1m) long. Two buckets Nontoxic antifreeze approximately 1 quart (1 liter). 4

5 Sea Water Model (Integral Pump) Sea Water Model (Remote Pump) Nontoxic Antifreeze Steps 1. Close intake and discharge seacocks. 2. Turn off power to unit. 3. Disconnect and drain intake hose, discharge hose and In-Line Strainer. 4. Connect short hoses to toilet s intake and discharge. 5. Place one bucket under hose connected to toilet s discharge. 6. Pour nontoxic antifreeze in other bucket. 7. Place hose connected to intake pump into bucket with antifreeze. 8. Turn on power to unit and flush toilet until antifreeze begins to be discharged from toilet. 9. Disconnect power to toilet. WINTERIZING Nontoxic Antifreeze RECOMMISSIONING 1. Using buckets, hoses and approximately one gallon (3.8 liters) of clean fresh water, flush antifreeze out of the toilet (see Winterizing Instructions). Dispose of antifreeze in accordance with local and federal regulations. 2. Reconnect intake and discharge hoses and open water source valve. 3. Proceed to System Start-Up. SYSTEM START-UP 1. Open seacock(s). NOTE: Pressurized freshwater models; open water source valve. 2. Turn on power to toilet. 3. Flush toilet per Operation Instructions. 4. Check for leaks. 5

6 SPECIFICATIONS Parts Included All Complete Toilets Toilet Bowl Seat and Cover A7 and A8 Model A9 Model - Wall Switch Flush Control Panel Straight Discharge (except -01 models) Vinyl Caps (2) Nylon Shoulder Washer (2) Sea Water Model In-Line Strainer with fittings Intake Pump Pressurized Freshwater Models Solenoid Valve with fittings Atmospheric Vacuum Breaker Additional Parts Required (minimum) Two stainless steel mounting bolts or lag screws (minimum 1/4" [6mm]) and washers) 1 1/2" (38mm) I.D. discharge hose 3/4" (19mm) I.D. reinforced intake hose 3/4" (19mm) hose clamps 1 1/2" (38mm) hose clamps Wire Wire Connectors Fuse/circuit breaker Minimum Tools Required (will depend on fasteners) Screwdrivers Wrenchs Drill bits Jig Saw Wire cutters Wire connector crimpers Hose cutters Tape measure Level Width: 2 3/4" (7cm) Depth of base: Normal: 15" (38cm) Elongated: 18 (46cm) Height: 4 1/2" (11.5 cm) SPECIFICATIONS Width of base: 14" (36cm) Depth of top: Normal bowl: 19 1/2"" (50cm) Elongated bowl: 21 (53.8cm) Height w/ seat and cover: 17 3/" (44cm) 6

7 Plumbing Pressurized water source Maximum suction of intake pump (maximum height above waterline) Maximum height NOTES: for Wiring of discharge vented loop Minimum flow rate - 3 gallons per minute (11.3 liters per minute) Minimum pressure - 5psi (34.5 kpa) 4 ft. (1.2 M) from Intake Pump 6 ft. (1.7 M) from floor 1. Distances are from source to unit and back to source Recommended conductor wire minimum (mm ) for 3% voltage drop Atlantes w/intake pump - Recommended Wire and Fuse/Circuit Breaker Size Units Voltage o Recommended conductor sizes are based on 5 C rated insulation. Refer to ABYC Standards for other insulation ratings. For 0/240 VAC units use 24VDC specifications from transformer to unit. Circuit Breaker/fuse size (amps) Amp. nominal voltage VDC VDC SPECIFICATIONS 32 VDC Branch to Remote intake pump (if used) VDC VDC VDC 14 CONVERSIONS Wire - to mm mm Feet to Meters Feet Meter Atlantes w/solenoid valve - Recommended Wire and Fuse/Circuit Breaker Size Units Voltage Circuit Breaker/fuse size (amps) Amp. nominal voltage VDC VDC VDC

8 INSTALLATION Mounting Toilet Mounting surface must be flat and solid. 1. Install seat on toilet. 2. Place toilet where it will be located. Make sure there is room to route hoses. Make sure seat will open properly. 3. Using a pencil, mark location of bowl mounting holes. 4. A. If hoses will be routed through floor, trace one side of toilet on floor. B. If hoses will be routed through wall, trace one side of toilet on wall. 5. Remove toilet and mark location for hoses on deck or wall. 6. Cut necessary holes using enclosed template through wall or floor. 7. Drill holes for toilet mounting bolts/ screws. NOTE: Use 1/4" [6mm] size bolts/screws. To select proper Screw or Bolt length, measure thickness of deck plus 1 1/8'' (29mm). TIP: Secure toilet to floor after installation is complete. CAUTION: Do Not over tighten mounting bolts. Damage to the toilet bowl may occur. Tighten both mounting bolts evenly and slowly. C A B C D E F A.Vinyl cap - #VCap (supplied) B. 1/4-20 S/S Bolt, or 1/4 S/S Self Tapping Screw, or 1/4 S/S Lag bolt C. Flat Washer, Stainless Steel D. Nylon Shoulder Washer - #F071 (supplied) E. S/S Lock washer (used on top and bottom for Nut and Bolt) F. 1/4-20 S/S Nut 8

9 A9 Models Only Mounting Atlantes Wall Mounted Flush Control IMPORTANT: Locate where wires can be routed. NOTE: The control panel cable length is 14' (427cm) Minimum depth of 2 1/2" (6.3cm) from surface is required. Parts Included Back plate assembly Bezel #4 x 1/2" screws for surface mounting (4) #6-32 x 7/8" screws for receptacle box mounting (2) Gasket Tools Required Flat blade screw driver Level For surface mount 2 1/8" (54mm) hole saw Drill with 5/64" (2mm) drill bit Surface Mounting 1. Attach template provided to mounting surface. Make certain it is level. 2. Drill four 5/64" (2mm) holes. 3. Drill one 2 1/8" (54mm) hole with hole saw. 4. Install gasket on back plate. 5. Connect control panel cable (See Wiring). 6. Secure back plate to surface using #4 x 1/2" screws (4). NOTE: Before securing back plate see J1 Jumper settings for Wall Mounted Flush Control under Changing Flush Times 7. Attach bezel to back plate. Receptacle Box Mounting 1. Cut out surface the size of receptacle box. 2. Mount receptacle box. 3. Install gasket on back plate. 4. Connect control panel cable (See Wiring). 5. Secure back plate to receptacle using #6-32 x 7/8" screws (4). NOTE: Before securing back plate see J1 Jumper settings for Wall Mounted Flush Control under Changing Flush Times 6. Attach bezel to back plate /2" (6.3cm) min. #4 x 1/2" screws #6-32 x 7/8" screws INSTALLATION

10 INSTALLATION Mounting In-Line Strainer (Sea Water Models Only) Make sure strainer bowl is tight. 1. Locate strainer where it will be accessible. 2. Mark and drill mounting holes. NOTE: Minimum 1/4" (6mm) size bolts/screws are recommended. 3. Install fittings provided (PLA14) on strainer s inlet and outlet ports using PTFE tape (included). 4. Mount strainer according to flow marking on strainer top. Mounting Remote Intake Pump (Remote Pump Models Only) 1. Remote intake pump must be mounted on a flat solid surface in an area that is dry and well ventilated. 2. Mark and drill mounting holes. NOTE: Minimum 1/4" (6mm) size bolt/screws are recommended. 3. Mount pump. Do not over tighten bolts. Flow Marking Mounting Water Solenoid Valve (Pressurized Freshwater Models Only) 1. Locate water solenoid valve on a solid flat surface in an area that is dry and well ventilated. 2. Mark and drill holes for water solenoid valve mounting bracket. NOTE: Minimum 1/4" (6mm) size bolt/screws are recommended. 3. Mount bracket. 4. Install fittings provided (PLA14) on water solenoid valve s inlet and outlet ports using PTFE tape (included). 5. Attach water solenoid valve to bracket. Hoses must be installed according to flow markings on valve body. Mounting Atmospheric Vacuum Breaker (Pressurized Freshwater Model only) 1. Install fittings as shown. 2. Locate mounting area that is a minimum of 6" (15.3cm) above toilet. 3. Secure where top is in horizontal position. From Pressurized Freshwater Source IN OUT PLA14 To inlet port of vacuum breaker Min. of 6" (15.3 cm)

11 PLUMBING WARNING: Hazard of Flooding Toilets mounted at or below the waterline must have a vented loop installed in the discharge line. The top of the vented loop must be a minimum of 4" (cm) above the waterline at the boats greatest angle of heel (see vented loop manufacturer s instructions). Sea Water Models must also have a vented loop installed between the intake pump and the toilet bowl. Double clamp all below waterline connections. IMPORTANT Fittings and 90 bends should be kept to a minimum. In-Line Strainer must be installed on Sea Water Models per Installation Instructions. Failure to do so may void Warranty. Discharging untreated sewage is forbidden in all U. S. waters within the three-mile limit. Thru-hull fittings and seacocks must be installed where they are easily accessible. Use only quality reinforced hoses. Secure all hoses properly. To retain water in bowl see section Retaining Bowl Water in installation/wiring section. Atlantes with Integral Pump and Atlantes Deodorant System installed above waterline. Waterline Vented Loop Discharge Seacock Vented Loop Lectra/San Discharge Seacock T-Check Valve must be installed Atlantes with Remote Intake Pump installed below waterline. Vented Loop Lectra/San Remote Intake Pump In-Line Strainer Atlantes In-Line Strainer Vented Loop Atlantes Plastic Tubing Clamp Intake Seacock Intake Seacock Waterline Atlantes Deodorant System Waterline Atlantes with Water Solenoid Valve (#A5F* or A6F*) for water system connection with holding tank. Atmospheric Vacuum Pump Out Breaker INSTALLATION Drawings are not to scale and intended only as a general reference. Discharge Lines 1. Connect quality 11/2 (38mm) I.D. sanitation hose to discharge fitting. 2. Run hose to appropriate Marine Sanitation Device. NOTE: Discharge hose runs longer than (4.9m) should install a vented loop near toilet to force waste beyond vented loop to drain by gravity. Solenoid Valve Waterline Holding Tank 11 Shut-off Valve Atlantes Potable Water Supply Discharge Fitting Discharge Hose 6" (15cm) Min. Waterline

12 INSTALLATION Intake Lines Pressurized Freshwater Models WARNING: Hazard of potable water contamination. An atmospheric (anti-siphon) vacuum breaker must be used with any installation using a potable water source. Install a shut off valve in intake line before water solenoid valve. 1. Connect hose from shut off valve to inlet port of water solenoid valve. NOTE: To avoid malfunction of water solenoid due to debris in water, installation of Freshwater Strainer (190601) is recommended. 2. Connect hose from outlet port of water solenoid valve to inlet port of vacuum breaker. 3. Connect hose from outlet port of vacuum breaker to bowl elbow. NOTE: Vacuum breaker must be last mechanical component before bowl elbow. From Pressurized Freshwater Source (Shut Off Valve) Outlet Port Inlet Port IN OUT To Inlet Port of Vacuum Breaker Sea Water Models Intake pump fittings are interchangeable to allow more flexibility during installation. Inlet ports are located on either side of intake pump. Outlet port (to toilet bowl) is at top of intake pump. 1. Slide fitting clips to open position. 2. Select inlet port to be used. (Integral models - only one port is available) 3. Install appropriate fittings into inlet and outlet ports. NOTE: The 90 fitting can be rotated Install the plug fitting into unused inlet port. (Integral models - plug is pre-installed) IMPORTANT: Be sure not to install plug fitting into outlet port! Damage will occur! 5. Slide fitting clips back to closed position. 6. Connect hose from seacock to inlet port of In- Line Strainer. Use hose clamp provided. 7. Connect hose from outlet port of In-Line Strainer to inlet port of intake pump. Use hose clamp provided. IMPORTANT: Double clamp all below waterline hose connections! Remote Pump Models - Connect hose from outlet port of intake pump to bowl elbow located on back of toilet bowl. (Integral pump model is Open Outlet Port Arrow Inlet Ports Closed To Bowl From Seacock From Strainer Plug To Intake Pump

13 already connected). WIRING WARNING: Hazard of Shock and Fire Always use proper wire and fuse/circuit breaker. See Specification Chart. Secure wire properly. Do not connect appliances to toilet circuit. Make sure power is off before proceeding. Use proper wire terminals for all wire connections. 1. Determine proper wire size by measuring distance from power source to toilet motor back to power source. 2. Select proper gauge wire and fuse/circuit breaker size from Specifications. 3. Install fuse/circuit breaker in positive line at source. 4. Connect positive wire from fuse/circuit breaker to red (POS) at rear of bowl. 5. Connect wire from battery negative or power source ground buss to black (NEG) at rear of bowl. Remote Intake Pump: Connect red and black 8 wire at back of bowl labeled remote pump - red wire (POS) to orange wire and black wire (NEG) to black wire of remote intake pump. Red Battery POS Black Battery NEG Red Battery POS Black Battery NEG T-check Valve (In-Line) Black Red Black Org Remote Intake Pump INSTALLATION / WIRING Pressurized Freshwater Solenoid Valve: Connect black and orange wire from back of bowl to water solenoid valve. Water solenoid is not polarity sensitive. 0/240 VAC Units: For proper wire gauge and circuit breaker from Transformer (#RTAH24D) to unit refer to 24 VDC specifications. To connect power to transformer refer to Installation Instructions included with #RTAH24D. Red Battery POS Black Battery NEG Orange Black Solenoid Valve Atlantes with Wall mounted Flush Control Panel (A9 Models): Unroll cable from toilet control and route to opening on the wall. Attach cable to the back of Atlantes Wall mounted Flush Control Panel. Secure cable every 18 inches (46cm). Do not damage insulation. Toilet Control 13

14 Flush Lever Toilets (A8 Models): NOTE: A discharge vented loop MUST be installed to retain water in the bowl. To retain water in bowl turn extend flush switch ON (located on Toilet Control). Inlet pump will continue to run a few seconds after discharge pump has stopped. Unit with factory installed internal vented loop is preset to ON position. CHANGING FLUSH TIMES Flush Lever Toilets (A8 Models): The normal flush is factory pre-set for approximately seconds. Installations that require longer flush times can be changed by setting switch number 2 and 3 per flush time adjustment chart Retaining Bowl Water Wall Switch Flush Control Panel (A9 Models): NOTE: A discharge vented loop MUST be installed to retain water in the bowl. To retain water in bowl set switch 1 of J1 to ON. Intake pump will continue to run a few seconds after discharge pump has stopped. Changing Flush Time Wall Switch Flush Control Panel (A9 Models): Normal flush can be set to flush for,, 14 or seconds by setting switches 2 and 3 located behind the wall switch flush control panel. Water Saver Flush will be half of the time set by these jumpers. INSTALLATION \ WIRINGRetaining Bowl Water Adjusting the flush time can be done from either the Toilet Control or from the Wall Switch. However, one must to be set to off and then flush times can be adjusted. Having both set to on will cause one to override the other. For ease of changing settings, it is suggested that the Flush Control be set to off and adjustments be made from the rear of the wall swith. If you wish to insure that water comes into the bowl at the end of the flush, be sure to set switch 1 to the on position. Toilet Control $1*( 72,/(7 &21752/ 5$5,7$1 )520 /67,17$.( %/8( 72 /67 ',6&+ :+,7( )/86+&21752/ 3$1(/ 1(* %/$&. (;7(1')/ )) )/86+7,0( Flush Time Adjustment J1 Switch Settings SWITCH NUMBER 2 3 ON ON OFF FLUSH TIME SECONDS ON OFF ON 14 OFF OFF 14

15 Upgrading from A7 to A8: 1. Turn off power 2. Remove mounting screws and slide bowl forward slightly 3. Locate and gently pull the 4 wires for the toilet control leaving some slack to make connections 4. Install all four wires on toilet control following the correct color code 5. Set timer to desired settings - see changing flush times 6. Check operation by turning on power 7. Install box in place by pressing firmly reclosable fastner 8. Mount the bowl INSTALLATION / WIRING 15

16 TROUBLESHOOTING Unit does not activate or flush: No power to unit Check main circuit breaker/switch check wiring to unit Overload/jammed discharge Reset A9 model by turning off power if unit runs for few second only and stops again see how to clear jam/clog Unit runs as soon as power is turned on: Reversed polarity Check and correct polarity Stuck handle Make sure handle is not stuck in on position Failed timer control Disconnect timer control and check Bowl does (see replacing not retain timer) water: A vented loop (external or internal is required to retain water in the bowl) Check jumper settings for extended flush Clogged vent check and clear vent in the loop Water in the vent line ventline must be run to avoid dips or low Poor spots or no flow from rim of the bowl: Clogged intake strainer check and clean strainer basket Air leak in suction line repair No activation of inlet pump/solenoid Check if pump or solenoid has power replace or repair if power but no activation Bowl fills up/ poor discharge out of bowl Low voltage below 11.5V Clogged discharge pump See how to clear Jam/clog Clogged discharge line/clogged vent check and repair Failed water solenoid Check if water solenoid shuts off completely, repair if needed Replacing/checking toilet control: 1. Turn off power 2. Remove mounting screw and slide bowl forward slightly 3. Remove control from reclosable fastner 4. Pull box out until all wires are accessible 5. Disconnect wires using needle nose pliers, do not pull on wires, pull connectors 6. Install new control 7. Check operation by turning on power 8. Install box in place by pressing firmly on reclosable fastner 9. Mount the bowl How to clear Jam/clog A7 Model: Disconnect POS and NEG wires at battery Note: Do not disconnect any wires at toilet control box Connect NEG to POS and POS to NEG Push handle back until discharge starts to run Repeat several times, this causes motor to run in reverse and should clear most clog s Reconnect NEG to NEG and POS to POS A8 and A9 models: Disconnect POS and NEG wires at battery Note: Do not disconnect any wires at toilet control box Connect NEG wire to POS from battery MOMENTARILY connect POS from toilet to NEG from battery until discharge starts running Reconnect NEG to NEG and POS to POS Tip for Removing Intake Pump Plug Set screw must be loosened with 1/8" hex key before removing the intake pump from motor

17 F7 AM660W AM661 F147VT 22B 501*W (A8) 502*W (A9) AM667 AM666 AM662 AM660 AM664 AM663 36AW CH43 AM519 CH43 TOILET CONTROL - MODELS A8 AND A9 22AW C254 AM141 AM140 F148VT WALL MOUNTED FLUSH CONTROL E AM130A F5NP AM031 F6 AM114 AM2 F W SOLENOID VALVE PLA14 CWPS*A ATW640+ CWPSMB AM030+ AL030+ (elongated) M23A CH20B F4 24 F145VT AM1 AM1 AM028 F089 ETB3 F W 2420 PLA AM001+ AL001+ (elongated bowl) F M23A 2135 F2VT F ATMOSPHERIC VACUUM BREAKER PLA13 AM665 F111 M23A AM601* F089 AM5 26B 60*A 1118 F035 F A 2305 PLA14 PLAVB0-5 F1 AM515 F W EXPLODED PARTS 1118 F M23A F143VT HSBI RNI M31 M31 M30 HLWQB F069 AM020B W (optional) SEA WATER STRAINER ASSEMBLY 3000 Optional T-Check Valve Optional Deodorant System D W CH CH E D W W G C H F

18 PARTS LIST PART # DESCRIPTION 1118 (4) 1/4" Locking Star Washer 1119 (2) 1/4-20 x 3/4 Hex screw 22AW 90 Discharge w/flange 22B Straight Discharge 26B (2) 1/4-20 Nut S/S 36AW Spud Assembly 36E Bowl Elbow 20W Upper Housing Assembly 2135 (4) Cone Seal 2200W Middle Housing Assembly 2225 O-Ring 2300W Lower Housing Assembly 2305 Lower Housing 23 Diaphragm 2315 Piston (4) 2320 Piston Seat (4) 2325A Bearing Plate Assembly /4" Hose Barb 90 Fitting 24 3/4" Hose Barb Straight 2415 Plug Fitting 2420 (3) Fitting Clip 2425 (3) O-Ring 60*A Pump Motor 31-2 Motor Shaft Seal Bowl Elbow (Freshwater Units not shown) AM001+ Atlantes Bowl (white) AL001+ Atlantes Elongated Bowl (white) AL030+ Atlantes Elongated Seat and Cover (white) AM020B Pump Mounting Bracket AM028 (2) Bushing AM030+ Atlantes Seat & Cover (white) AM031 Discharge Connection (3 pieces) AM1 Discharge Pump Back AM114 Discharge Pump "0" Ring AM130A Discharge Pump Body AM140 Discharge Cover AM141 Discharge Cover O-Ring AM1 Grinder Impeller AM2 Grinder Teeth AM5 Terminal Block Bracket AM203 Remote Inlet Pump Base (not shown) AM515 Atlantes Pump Mounting Bracket AM519 Intake Hose from diaphragm pump AM601* Discharge Motor C254 Joker Valve CH20B # SS Flat Washer CH43 (2) Hose Clamp S/S ETB3 Terminal Block F005 (2) 1/4-20 x 5/ SS Hex Socket Set Screw F035 (3) Isolation Nut F069 (2) 1/4" Fiber Washer F071 Nylon Shoulder Washer (not shown) F089 (3) 1/4-20 x 1 3/4" Rnd. Hd. Screw S/S F4 Panel Nut Brass Hex 5/8-32 x 7/8 x 1/8 F5NP (2) 1/4-28 set screw with nylon patch F6 (2) Plastite screw #6 x 3/4 F8 (2) Screw #4 x 7/8 F111 (4) -32 S/S Nut F1 (2) 8-32 x 1/4 Screw F142VT (8) -32 x 5/8" Pan Hd. S/S Screw (not shown) F143VT (2) -32 x 1" Pan Hd. SLTD S/S Screw F144 (6) # S/S Flat Washer F145VT -32 x 1 3/4" Pan Hd. SLTD S/S Screw F146VT (2) 1/4-20 x 1 1/4" Rnd Hd. Screw S/S W/VT F147VT (2) 3/8- x 1 1/2" Rnd Hd. Screw S/S F148VT (8) 8-32 x 7/" S/S Truss Hd. Screw F2VT (4) Mounting Bolt F172 (4) Plastite Screw # x 1/2 HLWQB (4) 1/4" Split Lock Washer HSB1 (2) 1/4-20 Brass Screw M23A (19) # Lockwasher S/S M30 (4) 1/4-20 Brass Nut M31 (8) 1/4" Brass Flat Washer RNI (2) Nylon Shoulder Washer VCAP (2) Vinyl Cap (screw head covers - not shown) 18 LEVER FLUSH CONTROL (A7 and A8 Series) AM600W Flush Switch Assembly, w/wire harness F7 (5) #4 x 1/4 Phlps. Pan Hd. Screw S/S AM660 Enclosure AM661 Cover AM662 Lever (internal) AM663 Enclosure Bushing AM664 Handle Shaft AM665 Flush Handle, S/S AM666 Spring AM667 (2) Snap Action Switch AM668 (2) Clip Bearing (not shown) WALL MOUNTED FLUSH CONTROL (A9 Series) 26A 1/4-20 X 1 1/4 Rnd. Hd. Screw S/S Cable for Flush Control (14 ft.) AM028 Bushing AM6W Flush Control wire harness assembly ATW* Flush Control PCB Assy. ATW640 Flush Control with Bezel Back Plate (White) ATW640A Flush Control with Bezel Back Plate (Bone) ATW640B Flush Control with Bezel Back Plate (Black) F153 #4 1/2 Oval slotted F170 6/32-7/8 screw OTHER PARTS 300 Swawater Strainer Assembly AM019S Silicone Cap, used on A9 only, in place of Flush lever (not shown) AJ138 Nylon Washer, used on A9 only (not shown) SOLENOID VALVE CWPS*A 1/2" GC Solenoid Valve CWPSMB Mounting Bracket for CWPS* PLA14 (2) 1/2" MPT to 3/4" Barbed Nipple ATMOSPHERIC (ANTI-SIPHON) VACUUM BREAKER PLA13 1/2" NPT to 3/4" Hose Elbow PLA14 1/2" MPT to 3/4" Barbed Nipple PLAVB0-5 Atmospheric (anti-siphon) Vacuum Breaker OPTIONAL T-CHECK VALVE PARTS LIST D Valve Body D1 Outlet Adapter E O Ring W T-Check Valve Assembly Complete W Siphon Check Valve CH8 Check Valve Spring CH Check Ball OPTIONAL DEODORANT/SALT FEED PARTS LIST (ADS) Salt Feed Tank Salt Feed Tank Cap C Plastic Tubing Clamp F Bulkhead Fitting G Bulkhead Fitting Nut H Bulkhead Fitting Seal W Assembly (includes part #'s C, F, G, H, ) PVC Clear Tubing 1/4" ADDITIONAL ACCESSORIES AVAILABLE FROM RARITAN 1PCP22 C.P., Cleans Potties, Bio-enzymatic toilet cleaner, 22 oz. bottle AHDA1W Internal Vented Loop CON22 Raritan Concentrate 22 oz. bottle SH Sanitation Hose (sold by the foot) VL 1 1/2 Vented Loop 1 1/2" VL 3/4 Vented Loop 3/4" YV "Y" Valve RTAH24DA Trnsfrmr./Rctfr. for 0/240 VAC (not shown) Parts are NOT included with Wall Switch Flush Control Models +CHOICE OF COLOR *SPECIFY VOLTAGE

19 19 NOTES

20 LIMITED WARRANTY Raritan Engineering Company warrants to the original purchaser that this product is free of defects in materials or workmanship for a period of one year from the product s date of purchase. Should this product prove defective by reason of improper workmanship and/or materials within the warranty period, Raritan shall, at its sole option, repair or replace the product. 1. TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with a detailed description of the problem, to Raritan at 530 Orange St., Millville, N.J , or 31 SW 2nd Ave. Ft. Lauderdale, FL When requesting warranty service, purchaser must present a sales slip or other document which establishes proof of purchase. THE RETURN OF THE OWNER REGISTRA- TION CARD IS NOT A CONDITION PRECEDENT OF WARRANTY COVERAGE. However, please complete and return the owner Registration Card so that Raritan can contact you should a question of safety arise which could affect you. 2. THIS WARRANTY DOES NOT COVER defects caused by modifications, alterations, repairs or service of this product by anyone other than Raritan; defects in materials or workmanship supplied by others in the process of installation of this product; defects caused by installation of this product other than in accordance with the manufacturer s recommended installation instructions or standard industry procedures; physical abuse to, or misuse of, this product. This warranty also does not cover damages to equipment caused by fire, flood, external water, excessive corrosion or Act of God. 3. ANY EXPRESS WARRANTY NOT PROVIDED HEREIN, AND ANY REMEDY FOR BREACH OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR OPERATION OF LAW, IS HEREBY EXCLUDED AND DISCLAIMED. ALL IMPLIED WARRAN- TIES SUCH AS THOSE OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, IF APPLICABLE, AS WELL AS ANY IMPLIED WARRANTIES WHICH MIGHT ARISE BY IMPLICATION OF LAW, ARE EXPRESSLY LIMITED TO A TERM OF ONE YEAR. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG A LIMITED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. 4. UNDER NO CIRCUMSTANCES SHALL RARITAN BE LIABLE TO PURCHASER OR ANY OTHER PERSONS FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER ARIS- ING OUT OF BREACH OF WARRANTY, BREACH OF CONTRACT, OR OTHERWISE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE- QUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU 5. No other person or entity is authorized to make any express warranty, promise or affirmation of fact or to assume any other liability on behalf of Raritan in connection with its products except as specifically set forth in this warranty. 6. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. L kgs Specifications Subject to Change Without Notice Printed in USA Orange Street Millville, NJ USA Telephone: FAX: SW Second Avenue, Fort Lauderdale, FL USA Telephone: FAX:

ATLANTES Household Style Marine Toilet - Water Saver Feature Model (Model A5 and A6 - Manufactured after June 2002)

ATLANTES Household Style Marine Toilet - Water Saver Feature Model (Model A5 and A6 - Manufactured after June 2002) ATLANTES Household Style Marine Toilet - Water Saver Feature Model (Model A5 and A6 - Manufactured after June 2002) THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION

More information

SeaEra Toilet OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS

SeaEra Toilet OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS SeaEra Toilet OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS WARNING: WARNING: WARNING: THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION.

More information

SeaEra QC Toilet. Series QC, Model 162 (manufactured after June 2014) OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS

SeaEra QC Toilet. Series QC, Model 162 (manufactured after June 2014) OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS SeaEra QC Toilet Series QC, Model 162 (manufactured after June 2014) OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS WARNING: WARNING: WARNING: THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE

More information

SeaEra QC Toilet Series QC, Model 162 (manufactured after June 2014) OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS

SeaEra QC Toilet Series QC, Model 162 (manufactured after June 2014) OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS SeaEra QC Toilet Series QC, Model 162 (manufactured after June 2014) OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS WARNING: WARNING: WARNING: THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE

More information

ATLANTES. Household Style Marine Toilet - Water Saver Feature Model (Model A5 and A6)

ATLANTES. Household Style Marine Toilet - Water Saver Feature Model (Model A5 and A6) ATLANTES Household Style Marine Toilet - Water Saver Feature Model (Model A5 and A6) THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING:

More information

ATLANTES FREEDOM TM TOILET VORTEX-VAC TM

ATLANTES FREEDOM TM TOILET VORTEX-VAC TM THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION. WARNING: WARNING: ATLANTES FREEDOM TM TOILET VORTEX-VAC TM Installation and Maintenance Instructions

More information

PH SUPERFLUSH INSTALLATION AND MAINTENANCE INSTRUCTIONS

PH SUPERFLUSH INSTALLATION AND MAINTENANCE INSTRUCTIONS PH SUPERFLUSH INSTALLATION AND MAINTENANCE INSTRUCTIONS THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING: Raritan Engineering Company,

More information

Hold n Treat Holding Tank Processor Installation and Maintenance Instructions

Hold n Treat Holding Tank Processor Installation and Maintenance Instructions Hold n Treat Holding Tank Processor Installation and Maintenance Instructions THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING: Raritan

More information

PH SUPERFLUSH AND PH POWERFLUSH Installation, Operation and Maintenance Instructions

PH SUPERFLUSH AND PH POWERFLUSH Installation, Operation and Maintenance Instructions PH SUPERFLUSH AND PH POWERFLUSH Installation, Operation and Maintenance Instructions THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING:

More information

PURASAN. OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS (Models PST*02 and PST*03 [*specify 12,24,32] Manufactured after September, 2004)

PURASAN. OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS (Models PST*02 and PST*03 [*specify 12,24,32] Manufactured after September, 2004) PURASAN OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS (Models PST*02 and PST*03 [*specify 12,24,32] Manufactured after September, 2004) THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ

More information

JETT TOILET SYSTEM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INTRODUCTION MAINTENANCE

JETT TOILET SYSTEM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INTRODUCTION MAINTENANCE JETT TOILET SYSTEM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING: Raritan Engineering

More information

Hold n Treat SYSTEM Installation and Maintenance Instructions

Hold n Treat SYSTEM Installation and Maintenance Instructions Hold n Treat SYSTEM Installation and Maintenance Instructions THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING: Raritan Engineering

More information

PHII AND PHEII MARINE TOILETS INSTALLATION AND MAINTENANCE INSTRUCTIONS

PHII AND PHEII MARINE TOILETS INSTALLATION AND MAINTENANCE INSTRUCTIONS PHII AND PHEII MARINE TOILETS INSTALLATION AND MAINTENANCE INSTRUCTIONS THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING: Raritan Engineering

More information

SMART TOILET CONTROL

SMART TOILET CONTROL SMART TOILET CONTROL Installation and Maintenance Instructions Part# THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION. WARNING: WARNING: Raritan

More information

Hold n Treat SYSTEM with PURASAN EX Installation and Maintenance Instructions

Hold n Treat SYSTEM with PURASAN EX Installation and Maintenance Instructions Hold n Treat SYSTEM with PURASAN EX Installation and Maintenance Instructions THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING:Raritan

More information

Internal PVC Rod-Style Fluid Level Sensor

Internal PVC Rod-Style Fluid Level Sensor Internal PVC Rod-Style Fluid Level Sensor New Providence Marine Systems INTERNAL PVC ROD SENSOR Copyright 2006 Topic Table of Contents Page 1:Introduction 2 2:Installation Guide 3 3:Limited Warranty 5

More information

PURASAN EX Hold n Treat OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS

PURASAN EX Hold n Treat OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS PURASAN EX Hold n Treat OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS WARNING: (Models PST*EX [*specify 12,24] Manufactured after December 2013) THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST

More information

PURASAN EX Hold n Treat OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS

PURASAN EX Hold n Treat OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS PURASAN EX Hold n Treat OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS WARNING: (Models PST*EX [*specify 12,24] Manufactured after December 2013) THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST

More information

crown head CENTRIFUGAL DISCHARGE SERIES AUTOMATIC MARINE TOILET INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

crown head CENTRIFUGAL DISCHARGE SERIES AUTOMATIC MARINE TOILET INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS crown head CENTRIFUGAL DISCHARGE SERIES AUTOMATIC MARINE TOILET INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION

More information

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS PumpAgents.com - Click here for Pricing/Ordering Model 36600-Series ELECTRIC BILGE PUMPS FEATURES Self-Priming Diaphragm Design Allows Dry Running Quiet Operation Built-in Hydraulic Pulsation Dampener

More information

TANK MONITOR SYSTEMS DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR INSTALLATION AND OPERATION MANUAL

TANK MONITOR SYSTEMS DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR INSTALLATION AND OPERATION MANUAL DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR INSTALLATION AND OPERATION MANUAL 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

External Non-Contact Fluid Level Sensor

External Non-Contact Fluid Level Sensor External Non-Contact Fluid Level Sensor NON-CONTACT SENSOR Tek Tanks Limited The Old Stables Tel: +44 (0)1420 520830 West End Farm Fax:+44 (0)1420 520840 Upper Froyle sales@tek-tanks.com Hampshire GU34

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

8700 Series MasterFlush. Macerator Toilet Operation manual. Mazerier-WC Bedienungsanleitung WC dilacérateur Mode d emploi...

8700 Series MasterFlush. Macerator Toilet Operation manual. Mazerier-WC Bedienungsanleitung WC dilacérateur Mode d emploi... EN Macerator Toilet Operation manual DE Mazerier-WC Bedienungsanleitung.... 13 FR WC dilacérateur Mode d emploi... 22 ES Inodoro triturador Manual de instrucciones.......... 32 NL Toilet met versnijdingspomp

More information

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13 GRINDER PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #2701-0005 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications) Flow Max Installation and Owner s Manual (For Aftermarket Applications) Table of Contents Introduction... 2 Parts List... 2 Resources Required... 3 Installation... 3 General Installation Instructions...

More information

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD PART NUMBER 393-008-020 Rev. C Table of Contents TABLE OF CONTENTS 393-008-020

More information

Intended Use: Explanation of Signal Word Consequences

Intended Use: Explanation of Signal Word Consequences SAFETY INFORMATION & INSTRUCTION MANUAL Please read, understand, and follow all safety information contained in these instructions prior to the use of this device. Retain these instructions for future

More information

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part # 29 July 2005 2003-04.5 Dodge Cummins OEM Bypass Lift Pump Kit # 1050227-1 - 2003-04½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part # 1050227 PLEASE READ ALL INSTRUCTIONS CAREFULLY

More information

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1099-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing

More information

G1000 Feeder IMPORTANT INFORMATION

G1000 Feeder IMPORTANT INFORMATION INSTALLATION GUIDE G1000 Feeder IMPORTANT INFORMATION Table of Contents Introduction...3 Installation...3 Exploded Parts Diagram...10 Operation...11 Feeder Overview...11 Filling the Feeder...11 Use of

More information

Illumifalls Patio Pond

Illumifalls Patio Pond Illumifalls Patio Pond REMINDER CALL 1-888-755-4497 BEFORE RETURNING TO STORE. Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-888-755-4497,

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Installation and Maintenance Instructions Limited One Year Warranty T&S warrants to the original purchaser (other than for purposes of resale) that such product is free from defects in material and workmanship

More information

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY NAVAL NAVAL I.I. Code No. 0816176 Rev. 1 INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS Certified Made in the U.S.A Exposed Closet Flushometer 1-1/2" Top

More information

ESE Series Cast Iron Sewage Pumps

ESE Series Cast Iron Sewage Pumps Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................

More information

Dual Flow Manifold Systems Instruction Manual

Dual Flow Manifold Systems Instruction Manual 3M TM Water Filtration Products Dual Flow Manifold Systems Instruction Manual For DF1XX and DF2XX High Flow Series manifolds and water filtration systems Installer: Please leave this manual with owner/operator.

More information

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL Flow Max Fluid Pump by Duraself OEM INSTALLATION MANUAL TABLE OF CONTENTS System and Safety Information 2 Resources Required 3 Installation 3 General Installation Instructions 3 Mounting Instructions 3

More information

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM) PumpAgents.com - Click here for Pricing/Ordering Models 41700 / 51700 - Series Washdown Pump WASHDOWN PUMP 0 PSI (5.5 BAR) 7.5 GPM (29 LPM) 6.0 GPM (23 LPM) FEATURES High Pressure / High capacity Pumpgard

More information

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODELS #1073-0001, 1075-0001 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

Rev: Flow Max 115V AC Fluid Pump

Rev: Flow Max 115V AC Fluid Pump Flow Max 115V AC Fluid Pump by Duraself Installation and Owner s Manual (For Aftermarket Applications) Table of Contents Introduction... 2 Parts List... 2 Resources Required... 3 Installation... 3 General

More information

StormPro BCV400 Sewage Ejector Pump

StormPro BCV400 Sewage Ejector Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including

More information

Mega-Flow External Damper Fans

Mega-Flow External Damper Fans Mega-Flow External Damper Fans With Cone Owner s Manual Hired-Hand, Mfg., Inc. PO Box 140 1733 County Road 68 Bremen, Alabama 35033 Part No. 4801-5402 Rev 4/08 Owners Manual Mega-Flow External Damper Fans

More information

Features and Benefits Wide Bottom: Translucent Bottle: 2 1/2 Gallon Bottle: Removable Bottle: Large cap: 15 Feet of Coiled Hose:

Features and Benefits Wide Bottom: Translucent Bottle: 2 1/2 Gallon Bottle: Removable Bottle: Large cap: 15 Feet of Coiled Hose: 12 Volt Battery Powered Sprayer This unit uses a lead acid battery. The charge capacity of the battery can be greatly diminished if fully discharged. Care should be given to charge the battery between

More information

AutoSparge. Lauter Tun Level Control. Operation, Assembly & Maintenance Manual

AutoSparge. Lauter Tun Level Control. Operation, Assembly & Maintenance Manual AutoSparge Lauter Tun Level Control Operation, Assembly & Maintenance Manual Congratulations on your purchase, and thank you for selecting the AutoSparge lauter tun level control from Blichmann Engineering.

More information

Colt Series C400, C500

Colt Series C400, C500 Colt Series C400, C500 RP/IS-A-C400/C500 C400 OSY Reduced Pressure Zone Assemblies Reduced Pressure Detector Assemblies Sizes: 2 1 2" 10" (65 250mm) Installation Service Repair Kits Maintenance For other

More information

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA Reduced Pressure Zone Assemblies Reduced Pressure Detector Assemblies Sizes: 2 1 2" 10" (65 250mm) Installation Service Repair Kits Maintenance RP/IS-957/957RPDA

More information

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14 SEWAGE PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1261-0001 Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

Neptune X6 12/24V SAE 316L Stainless Steel Low Profile Through-Hull Mounted Underwater LED Light Manual

Neptune X6 12/24V SAE 316L Stainless Steel Low Profile Through-Hull Mounted Underwater LED Light Manual Neptune X6 12/24V SAE 316L Stainless Steel Low Profile Through-Hull Mounted Underwater LED Light Manual Thank you for purchasing Dr. LED s Neptune X6 underwater LED light. This 1500+ lumen Neptune X6 underwater

More information

PRE-PLUMBED SEWAGE SYSTEM

PRE-PLUMBED SEWAGE SYSTEM PRE-PLUMBED SEWAGE SYSTEM Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1910-0009 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN AUTOMATIC S33A1 & S33A1C WARNING risk of electric shock.

More information

Models EST12, EST24 and EST32 Installation and Maintenance Instructions

Models EST12, EST24 and EST32 Installation and Maintenance Instructions Models EST12, EST24 and EST32 Installation and Maintenance Instructions THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING: Raritan Engineering

More information

Models EST12, EST24 and EST32 Installation and Maintenance Instructions

Models EST12, EST24 and EST32 Installation and Maintenance Instructions Models EST12, EST24 and EST32 Installation and Maintenance Instructions THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION WARNING: Raritan Engineering

More information

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14 F PRO SPRAYER by 12 Volt Electric Sprayer Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14 Table of Contents Feature and Benefits... 3 Specifications... 3 Complete Sprayer Diagram... 4 Complete Sprayer

More information

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS AEROMOTIVE Part # 17242 Generic Fuel System Kit INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend that

More information

AEROMOTIVE Part # & Generic Fuel System Kit INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # & Generic Fuel System Kit INSTALLATION INSTRUCTIONS AEROMOTIVE Part # 17135 & 17136 Generic Fuel System Kit INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend

More information

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps Installation Operation Repair Parts PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps Specifications Motor Type: 12 VDC, permanent magnet, totally enclosed, non-ventilated Leads: 14 AWG, 12

More information

Installation Instructions / Warranty

Installation Instructions / Warranty Installation Instructions / Warranty Axor Citterio 39133XX1 Axor Citterio 39135XX1 Axor Citterio 39233XX1 Axor Citterio 39235XX1 Axor Citterio Widespread Lavatory Faucet Axor Citterio Widespread Bidet

More information

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES APCO ASR-400/450 SEWAGE AIR RELEASE VALVES Instruction D12005 December 2012 Instructions These instructions provide installation, operation and maintenance information for the APCO ASR- 400/450 Sewage

More information

ILCS EDGE System Installation Manual

ILCS EDGE System Installation Manual ILCS EDGE System Installation Manual 0900885 Rev: A (12/06) Page 1 of 12 TABLE OF CONTENTS System Overview... 3 System Components... 3 System Diagram... 4 Pre-Installation... 5 Control Box & Power Supply

More information

VSP SERIES Installation, Operation and Maintenance Manual

VSP SERIES Installation, Operation and Maintenance Manual VSP SERIES Installation, Operation and Maintenance Manual VARIABLE SPEED PERISTALTIC METERING PUMPS VSP-12 and VSP-20 Models READ ALL WARNINGS CAREFULLY BEFORE INSTALLING PUMP PUMP DATA/SPECIFICATIONS

More information

Value Super Filter Max Installation Manual

Value Super Filter Max Installation Manual Value Super Filter Max Installation Manual Barrie, Ontario, Canada, L4N 4Y8 www.excaliburwater.com EXCALIBUR VALUE SUPER FILTER MAX INSTALLATION MANUAL INSTALLATION PROCEDURES: The Value Super Filter Max

More information

DODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

DODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part # 2/15/2006 2000-2002 Dodge Cummins OEM Bypass Lift Pump Kit # 1050229-1 - 2000-02 DODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part # 1050229 PLEASE READ ALL INSTRUCTIONS CAREFULLY

More information

AEROMOTIVE Part # & ½ L DOHC Return Style Fuel System Kit INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # & ½ L DOHC Return Style Fuel System Kit INSTALLATION INSTRUCTIONS AEROMOTIVE Part # 17145 & 17146 98 ½-04 4.6L DOHC Return Style Fuel System Kit INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair

More information

Scale Feeder Manifold Water Filtration System Instruction Manual

Scale Feeder Manifold Water Filtration System Instruction Manual 3M TM Water Filtration Products Scale Feeder Manifold Water Filtration System Instruction Manual For SF1XX High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator.

More information

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Dual/Triple Manifold Water Filtration Systems Instruction Manual 3M TM Water Filtration Products Dual/Triple Manifold Water Filtration Systems Instruction Manual High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator. 3M Water

More information

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids. Model #7575 Recommended Installation, Maintenance and Inspection Instructions 007 Tank Monitor 7575 Important safety instructions - save these instructions in a readily accessible location. WARNING Never

More information

Items # and #

Items # and # D I S P E N S E R T E C H N I C A L M A N U A L Items #91160-00 and #91161-00 1. System Description... 1 2. Equipment Included with the Green Earth II XL System... 2 3. Components Included with Green Earth

More information

AEROMOTIVE Part # Mustang 5.0L Fuel System Kit INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # Mustang 5.0L Fuel System Kit INSTALLATION INSTRUCTIONS AEROMOTIVE Part # 17103 83-93 Mustang 5.0L Fuel System Kit INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Limited One Year Warranty T&S warrants to the original purchaser (other than for purposes of resale) that such product is free from defects in material and workmanship for a period of one (1) year from

More information

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG BUNN COMBO BREWER DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG Designs, materials, weights, specifications, and dimensions for equipment or replacement

More information

RipTide. Brewing Pump. Assembly, Operation, & Maintenance

RipTide. Brewing Pump. Assembly, Operation, & Maintenance RipTide Brewing Pump Assembly, Operation, & Maintenance Congratulations on your purchase, and thank you for selecting the RipTide brewing pump from Blichmann Engineering. We are confident that it will

More information

Electric Pilot System Assembly, Operation, & Maintenance

Electric Pilot System Assembly, Operation, & Maintenance Electric Pilot System Assembly, Operation, & Maintenance Congratulations on your purchase, and thank you for selecting the Electric Pilot System from Blichmann Engineering Pro Series. We are confident

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Limited One Year Warranty T&S warrants to the original purchaser (other than for purposes of resale) that such product is free from defects in material and workmanship for a period of one (1) year from

More information

6. Electrical. 7. Settings. 8. Quick

6. Electrical. 7. Settings. 8. Quick Grundfos Variable Speed Circulator Pump Pumps Incorporating the VS, Variable Speed Control 1. Shipment Inspection Page 2 2. General Page 2 3. Operational Limits Page 3 4. Pump Installation Page 4 5. Installation

More information

Installation, Operation & Maintenance Manual. For Pro-Fill kits with part numbers beginning in BG

Installation, Operation & Maintenance Manual. For Pro-Fill kits with part numbers beginning in BG Installation, Operation & Maintenance Manual For Pro-Fill kits with part numbers beginning in BG BL-175 6/26/2009 General Information & Precautions This publication provides detailed instructions for installing

More information

AEROMOTIVE Part # and F-Body Fuel System Kit INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # and F-Body Fuel System Kit INSTALLATION INSTRUCTIONS AEROMOTIVE Part # 17101 and 17102 93-97 F-Body Fuel System Kit INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We

More information

ETF-600 Sensor Operated Lavatory Faucet

ETF-600 Sensor Operated Lavatory Faucet INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED LAVATORY FAUCET ETF-600 I.I. Code No. 0816318 ETF-600 Sensor Operated Lavatory Faucet Includes Instructions for Installation of Optional Back Checks

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL Models S120U & S240U Read all instructions before assembling or using the SunHeater system. Retain this manual for future use. TABLE OF CONTENTS Important Safety Information...2

More information

Artesian Owners Manual

Artesian Owners Manual Artesian Owners Manual Energy-Efficient, Self Priming Centrifugal Pumps Discharge Inlet Important Safety Instructions Please read all instructions completely before you install or operate your new pump.

More information

# and # FAST Fuel System Kits

# and # FAST Fuel System Kits 1 INSTRUCTIONS #307500 and #307501 Fuel System Kits Thank you for choosing products; we are proud to be your manufacturer of choice. Please read this instruction sheet carefully before beginning the installation.

More information

MetroPrime 22MPC Self-Priming Centrifugal Pump

MetroPrime 22MPC Self-Priming Centrifugal Pump Page 1 of 6 prevent priming or reduce pump capacity. OPERATION The 22 MPC-Metropolitan Pump is a self-priming centrifugal pump and only requires priming prior to its initial start. The pump will retain

More information

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL AL- Model Number Date Code / Serial Number Date of Purchase LIMITED WARRANTY ALITA warrants to the original retail consumer purchaser ( Customer ) that

More information

Manual Concentrate Management System

Manual Concentrate Management System Form 887 05/15 Manual Concentrate Management System with Automatic Flush INSTALLATION AND OPERATION MANUAL Unit Serial Number All quality FoamPro products are ruggedly designed, accurately machined, carefully

More information

SAFETY INFORMATION & INSTRUCTION MANUAL

SAFETY INFORMATION & INSTRUCTION MANUAL SAFETY INFORMATION & INSTRUCTION MANUAL Please read, understand, and follow all safety information contained in these instructions prior to the use of this device. Retain these instructions for future

More information

INSTALLATION, OPERATING AND SERVICE MANUAL

INSTALLATION, OPERATING AND SERVICE MANUAL INSTALLATION, OPERATING AND SERVICE MANUAL ECONO-mist WATER SOFTENER Demand Regeneration 7-LMC56-75B 7-LM56-75B 7-LM56-100B 7-LM56-150B 7-LM56-200B Congratulations on purchasing your new Lancaster Water

More information

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. PEDESTAL SUMP PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1084-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing

More information

Installation Instructions / Warranty

Installation Instructions / Warranty Installation Instructions / Warranty Interaktiv Retroaktiv 4-Hole Roman Tub Trim Interaktiv & Retroaktiv 4-Hole Roman Tub Trim These instructions cover the following trim kits: Interaktiv Solaris Stratos

More information

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD. Series 4000SS RP/IS-A-4000SS 4000SS Reduced Pressure Zone Assemblies Sizes: 8" 10" (200 250mm) Installation Service Repair Kits Maintenance For other repair kits and service parts, send for Ames Repair

More information

User Guide IGD Series

User Guide IGD Series US User Guide IGD Series DANGER PRIOR TO USE, READ AND UNDERSTAND PRODUCT SAFETY INFORMATION. Failure to follow the instructions may result in ELECTRICAL SHOCK, EXPLOSION, or FIRE, which may result in

More information

Installation Instructions

Installation Instructions Installation Instructions AMP RESEARCH Power Step by Bestop Automatic Retracting Running Board Vehicle Application Nissan Titan King Cab 2004 and newer (5 ft.) Part Number: 75106-01 Nissan Titan Crew Cab

More information

AEROMOTIVE Part # Street Rod Fuel Pump System INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # Street Rod Fuel Pump System INSTALLATION INSTRUCTIONS AEROMOTIVE Part # 17201 Street Rod Fuel Pump System INSTALLATION INSTRUCTIONS CAUTION: Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend

More information

www. hydrofuse.com Installation Manual Fertilizer Machine V1.3

www. hydrofuse.com Installation Manual Fertilizer Machine V1.3 www. hydrofuse.com Installation Manual Fertilizer Machine V1.3 Introduction Hydrofuse is a new concept in fertilizing that works with existing irrigation (sprinkler) systems and automatically dispenses

More information

Artesian2 Owners Manual

Artesian2 Owners Manual Artesian2 Owners Manual Energy-Efficient, Self Priming Centrifugal Pumps Discharge Inlet Important Safety Instructions Please read all instructions completely before you install or operate your new pump.

More information

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets INSTALLATION INSTRUCTIONS BATTERY POWERED SENSOR OPERATED HAND WASHING FAUCETS EBF-750 I.I. Code No. 0816324 EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets Includes Instructions

More information

Installation Instructions / Warranty

Installation Instructions / Warranty Installation Instructions / Warranty 13550181 Rough, Two-Hole Thermostatic Roman Tub 13550181 min 4 3/8 max 18 3/4 2 3/16 2 3/16 Technical Specification Operating pressure: max. 145 psi Recommended operating

More information

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source.

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source. OWNER S MANUAL RK2 Systems Pro Pump Energy-Efficient, Self Priming Centrifugal Pumps Important Safety Instructions Please read all instructions completely before you install or operate your new pump. Save

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Thank you for purchasing ROLTECTM Electric Hopper Conversion. Agri-Cover, Inc. proudly manufactured this hardware using superior quality materials and workmanship. With proper

More information

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual Installation, Operation & Maintenance Manual Picture may differ from your specific application For Pro-Fill kits with part numbers beginning in BG BL-175 9-20-13 General Information & Precautions This

More information