WCS2000 / WCS2000S. Features: WCS Series
|
|
- Lisa Snow
- 6 years ago
- Views:
Transcription
1 Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion resistance Vibration isolators between the engine/alternator and base frame Integrated wiring design Base fuel tank for at least 8 hours running Equipped with an industrial muffler Engine oil pump 50 radiator Top lifting and steel base frame with forklift holes Drainage for fuel tank Complete protection functions and safety labels IP44 (soundproof sets), IP54 (control system) Water jacket preheater, oil heater and double air cleaner, etc. are available. Output Ratings Generating Set Model Prime Standby WCS2000/S 1875kVA/1500kW 2063kVA/1650kW Ratings at 0.8 power factor. Ratings and Performance Data Dimensions and Weights Engine Make & Model: QSK60-G3 Generating Set Model Length (L) mm (in) Width (W) mm (in) Height (H) mm (in) Dry kg (lb) Alternator Model: Alternator Brand: Control System: PI734E STAMFORD PLC-8610 / PLC-7420 WCS2000 WCS2000S Dry = With Lube Oil Wet = With Lube Oil and Coolant Noise Level@7m: / Frequency & Phase: 50Hz & 3PH Engine Speed: RPM 1500 Structure Type: Fuel Tank Capacity: L Fuel Consumption: l/h WCS2000 WCS2000S WCS2000 WCS2000S at 100% load at 75% load A C / Also available in the following voltages: 415/240V-380/220V-220/127V-200/115V; ESP: Standby Power Standby duty, operation under variable load, without over load; PRP: Prime Power-Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 hours; The data is only for your reference but not for use of sales. M: Mechanical speed governor, E/ECU: Electronic speed governor; NA: Naturally aspirated, TC: Turbocharged, TCA: Turbocharged and air-air aftercooled. TCW: Water-cooled Turbocharged; The weights are approximate and without fuel
2 Engine model: QSK60-G3 GENERAL ENGINE DATA Type... Aspiration... 4-Cycle; 60 Vee; 16-Cylinder Diesel Turbocharged and Low Temperature Aftercooled (2 Pump / 2 Loop) Bore x Stroke... mm x mm (in x in) 159 x 190 (6.25 x 7.48) Displacement... litre (in 3 ) 60.2 (3673) Compression Ratio : 1 Dry Weight Fan to Flywheel Engine (with SAE 0 Flywheel and Flywheel Housing)... kg (lb) 7185 (15835) Wet Weight Fan to Flywheel Engine... kg (lb) 7540 (16620) Moment of Inertia of Rotating Components with FW 6043 Flywheel (SAE 0)... kg m 2 (lb m ft 2 ) (375.5) with FW 6037 Flywheel (SAE 00)... kg m 2 (lb m ft 2 ) (622.4) Center of Gravity from Front Face of Block... mm (in) 1001 (39.4) Center of Gravity Above Crankshaft Centerline... mm (in) 219 (8.6) Maximum Static Loading at Rear Main Bearing... kg (lb) 1134 (2500) ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... N m (lb ft) (7634) EXHAUST SYSTEM Maximum Back Pressure at 1500 RPM (Standby Power)... mm Hg (in Hg) 51 (2) AIR INDUCTION SYSTEM Maximum Intake Air Restriction with Dirty Filter Element... kpa (in H 2 O) 6.2 (25) with Clean Filter Element... kpa (in H 2 O) 3.7 (15) COOLING SYSTEM (Separate Circuit Aftercooling Required) Coolant Capacity Engine... litre (US gal) 157 (42) Aftercoolers... litre (US gal) 34 (9) Minimum Pressure Cap (for Cooling Systems with less than 2m [6 ft.] Static Head)... kpa (psi) 76 (11) Maximum Static Head of Coolant Above Engine Crank Centerline... m (ft) 18.3 (60) Jacket Water Circuit Requirements: Maximum Coolant Friction Head External to Engine 1500 rpm... kpa (psi) 48 (7) Maximum Top Tank Temperature for Standby / Prime Power... C ( F) 104 / 100 (220 / 212) Thermostat (Modulating) Range... C ( F) ( ) Aftercooler Circuit Requirements: Maximum Coolant Friction Head External to Engine 1500 rpm... kpa (psi) 35 (5) Maximum Inlet Water Temperature to 25 C (77 F)... C ( F) 49 (120) Maximum Inlet Water Temperature to Aftercoolers... C ( F) 65 (150) Thermostat (Modulating) Range... C ( F) ( ) LUBRICATION SYSTEM Oil Idle Speed... kpa (psi) 138 Governed Speed... kpa (psi) (50-70) Maximum Oil Temperature... C ( F) 121 (250) Oil Capacity with OP6073 Oil Pan: Low-High... litre (US gal) (61-69) Total System Capacity (with Combo Filter)... litre (US gal) 280 (74) FUEL SYSTEM Type Injection System... Cummins HPI-PT Maximum Restriction at PT Fuel Injection Pump with Clean Fuel Filter... mm Hg (in Hg) 120 (4.0) with Dirty Fuel Filter... mm Hg (in Hg) 203 (8.0)
3 Engine model: QSK60-G3 Maximum Allowable Head on Injector Return Line (Consisting of Friction Head and Static Head)... mm Hg (in Hg) 229 (9.0) Maximum Fuel Inlet Temperature... C ( F) 70 (160) Maximum Fuel Flow to Injection Pump... litre / hr (US gph) 1515 (400) Maximum Drain Flow... litre / hr (US gph) 1400 (370) ELECTRICAL SYSTEM Cranking Motor (Heavy Duty, Positive Engagement)... volt 24 Battery Charging System, Negative Ground... ampere 40 Maximum Allowable Resistance of Cranking Circuit... ohm Minimum Recommended Battery Capacity Cold 10 C (50 F) and Above... 0 F CCA 1800 Cold 0 C to 10 C (32 F to 50 F)... 0 F CCA 1800 Cold -18 C to 0 C (0 F to 32 F )... 0 F CCA 2200 COLD START CAPABILITY Minimum Ambient Temperature for Cold Start with watt Coolant Heater to Rated Speed... C ( F) TBD (TBD) Minimum Ambient Temperature for Unaided Cold Start to Idle Speed... C ( F) -12 (10) Minimum Ambient Temperature for NFPA 110 Cold Start (90 F Minimum Coolant Temperature)... C ( F) 10 (50) PERFORMANCE DATA All data is based on: Engine operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer; not included are battery charging alternator, fan, and optional driven components. Engine operating with fuel corresponding to grade No. 2-D per ASTM D975. ISO 3046, Part 1, Standard Reference Conditions of: Barometric Pressure : 100 kpa (29.53 in Hg) Air Temperature : 25 C (77 F) Altitude : 110 m (361 ft) Relative Humidity : 30% Air Intake Restriction : 381 mm H 2 O (15 in H 2 O) Exhaust Restriction : 51 mm Hg (2 in Hg) Steady State Stability Band at any Constant Load... % +/ Estimated Free Field Sound Pressure Level of a Typical Generator Set; Excludes Exhaust Noise; at Rated Load and 7.5 m ( rpm... dba 93.4 (est.) Exhaust Noise at 1 m Horizontally from Centerline of Exhaust Pipe Outlet Upwards at dba 108 (est.) STANDBY POWER PRIME POWER 60 hz 50 hz 60 hz 50 hz Governed Engine Speed... rpm Engine Idle Speed... rpm Gross Engine Power Output... kw m (BHP) 1790 (2399) 1615 (2165) Brake Mean Effective Pressure... kpa (psi) 2379 (345) 2144 (311) Piston Speed... m / s (ft / min) 9.5 (1869) 9.5 (1869) Friction Horsepower... kw m (HP) 146 (196) 146 (196) Not Not Engine Jacket Water Flow at Stated Friction Head External to Engine: Applicable for Applicable for 4 psi Friction Head... litre / s (US gpm) 26.5 (420) 26.5 (420) 1800 RPM 1800 RPM Maximum Friction Head... litre / s (US gpm) 25.2 (400) 25.2 (400) Operation Operation Engine Data Intake Air Flow... litre / s (cfm) 2255 (4780) 2150 (4555) Exhaust Gas Temperature... C ( F) 440 (820) 415 (775) Exhaust Gas Flow... litre / s (cfm) 5525 (11700) 5105 (10815) Air to Fuel Ratio... air : fuel 26.9:1 28.7:1 Radiated Heat to Ambient... kw m (BTU / min) 160 (9020) 145 (8165) Heat Rejection to Engine Jacket Radiator... kw m (BTU / min) 460 (26000) 420 (23950) Heat Rejection to Exhaust... kw m (BTU / min) 1120 (63700) 1020 (57950) Heat Rejection to Fuel*... kw m (BTU / min) 35 (2000) 35 (2000) Engine Aftercooler Data Heat Rejection to Aftercooler Radiator... kw m (BTU / min) 405 (22925) 355 (20175) Aftercooler Water Flow at Stated Friction Head External to Engine: 2 psi Friction Head... litre / s (US gpm) 7.1 (112) 7.1 (112) Maximum Friction Head... litre / s (US gpm) 6.9 (109) 6.9 (109) * This is the maximum heat rejection to fuel, which is at low load N.A. - Data is Not Available N/A - Not Applicable to this Engine TBD - To Be Determined
4 Alternator model: PI734E CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G. A.V.R. MX341 MX321 VOLTAGE REGULATION ± 1 % ± 0.5 % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) INSULATION SYSTEM PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS MAIN STATOR RESISTANCE MAIN ROTOR RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE R.F.I. SUPPRESSION CLASS H IP DOUBLE LAYER LAP TWO THIRDS Ohms PER PHASE AT 22 C STAR CONNECTED 2.17 Ohms at 22 C 17.5 Ohms at 22 C Ohms PER PHASE AT 22 C BS EN & BS EN ,VDE 0875G, VDE 0875N. refer to factory for others WAVEFORM DISTORTION MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR NO LOAD < 1.5% 1 BEARING 3556 kg 1747 kg 1494 kg NON-DISTORTING BALANCED LINEAR LOAD < 5.0% 2250 Rev/Min BALL C3 BALL C3 2 BEARING 3506 kg 1747 kg 1432 kg WR² INERTIA SHIPPING WEIGHTS in a crate PACKING CRATE SIZE kgm kg 3575kg 216 x 105 x 154(cm) 50 Hz kgm x 105 x 154(cm) 60 Hz TELEPHONE INTERFERENCE THF<2% TIF<50 COOLING AIR 2.69 m³/sec 5700 cfm 3.45 m³/sec 7300 cfm VOLTAGE STAR 380/ / / / / / / /277 kva BASE RATING FOR REACTANCE VALUES Xd DIR. AXIS SYNCHRONOUS X'd DIR. AXIS TRANSIENT X''d DIR. AXIS SUBTRANSIENT Xq QUAD. AXIS REACTANCE X''q QUAD. AXIS SUBTRANSIENT XL LEAKAGE REACTANCE X2 NEGATIVE SEQUENCE X0 ZERO SEQUENCE
5 Control System function list Control System PLC-7420 PLC-7420 is an advanced control module based on micro-processor, containing all necessary functions for protection of the genset and the breaker control. It can monitor the mains supply, breaker control. and automatically start the engine when the mains is abnormal. Accurately measure various operational parameters and display all values and alarms information on the LCD. In addition, the control module can automaticallyshut down the engine and indicate the engine failure. FEATURES Microprocessor control, with high stability and credibility Monitoring and measuring operational parameters of the mains supply and genset Indicating operation status, fault conditions, all parameters and alarms Multiple protections; multiple parameters display, like pressure, temp. etc. Manual, automatic and remote work mode selectable Real time clock for time and date display, overall runtime display, 250 log entries Overall power output display Integral speed/frequency detecting, telling status of start, rated operation, overspeed etc. Communication with PC via RS485 OR RS232 interface, using MODBUS protocol General accessory Operator Interface Measurement and Instrumentation Shutdown Protection and Indication Threshold Warning&Indication Paralleling Capability MODEL AVR Electronic Governing Glow plug control Cycle Cranking MODBUS Networking Fault History manual start/stop Auto/remote start Regular Test Auto operation LED Manual operation LED Common Shutdown LED Common warning LED Fail to start LED Emergency stop(local) Alphanumeric screen Remote start input active LED Alarm reset Oil pressure Water Temperture Engine Speed Engine Engine Altamator Altamator Mains Expression Hours Run Number of Starts Battery Voltage Coolant Temperature 3PhaseL-L Voltage&Frequency 3phase Current Frequency kwh Apparent Power Active Power and Reactive Power Power Factor Per PhasekW, kwr Per Phase kva Phase Voltage Output Power Grid Line Voltage Grid Phase Voltage Grid Frequency Low Fuel Level High Fuel Level Low Oil Pressure High Water Temperature Failure to Stop Failure to Start Controlable start circles/times Overspeed Under&Over Voltage Under&Over Frequency Overcurrent Earth Leakage Reverse Power Reverse kwr Low Oil Pressure Low Water Temperature High Water Temperature Low Water Level Low/High Battery Voltage Failure to Charge Overcurrent Overload Genset Under/Over Voltage Genset Under/Over Frequency under/over Speed High Engine Temperature Earth Leakage Synchroscope(Independent Bus) Active and Reactive Power Control Synchroscope(Shared Bus) Synchronization Dector Peak Lopping PLC-8610 PLC-7420 Power Transfer Function Environment Automatic Transfer Hard Closed Transition Soft Closed Transtion Gen/Mains Breaker Gen/Mains Breaker Status Protection Speed/Voltage Control Power Indication Fuel&solenoid Valve Control Startor Control Preheating Mains Transfer Switch (Standard) Mains Transfer Switch (Emergency) Operating Temperature ( ) Ambient Temperature ( ) Humidity 80% Monitoring Function Grid Over/Under Voltage Control Grid Over/Under Frequency Control Remote Start Output(Load/No-load) Optional Relay Output Remote Telecom Control with All Functions Engine Instrument Monitoring Altemator Output Instrument Monitoring Connection Point with All-around Setting For 6 Users 3 Users Input Connection Point LCD Light Control of Low Light Operation Environment Safe PIN Code RS232/485 Interface Language Selection Multi-Language Function Standard Optional Impossible
6 Control System Digital, intelligent control system allows easier operation. PLC-8610 (Optional) FEATURES Microprocessor control, with high stability and credibility Monitoring and measuring operational parameters of the genset Indicating operation status, fault conditions, all parameters and alarms Multiple protections; multiple parameters display, like pressure, temp. etc. Manual, automatic and remote work mode selectable RS232 & RS485 can be used at the same time Real time clock for time and date display, overall runtime display, 250 log entries PLC-8610 is a microprocessor based control unit containing all necessary functions for protection of the genset and the breaker control. Furthermore, it contains all necessary three-phase measuring circuits and presents all values and alarms on the LCD display. The module has the function of load sharing which enables the module to share the active load (kw) equally when operating in parallel with other gensets. The load sharing is performed so each genset takes a portion of the load that is calculated in percent according to the nominal power.
7 Optional Engine Alternator Generator Set Fuel System Canopy Water Jacket Preheater Oil Preheater Winding Temperature Measuring Instrument Alternator Preheater PMG Anti-damp and anti-corrosion treatment Anti-condensation heater Tools with the machine Low fuel level alarm Automatic fuel feeding system Fuel T-valves Lubricating System Exhaust System Cooling System Control Panel Voltages Oil with the machine Protection board from hotness Front heat protection Coolant (-30 C) Remote control panel PLC-8610 PLC-7420 ATS 415/240V 400/230V 380/220V 220/127V V PowerLink reserves the right to make changes in model, technical sepcification, color, configuration and accessories without prior notice. Please contact the salesman before ordering. WCS Series / May.2013
GMS1400C / GMS1400CS. Features: EC Series
Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion
More informationGMS100C / GMS100CS. Features: EC Series
Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion
More informationGMS450C / GMS450CS. Features: EC Series
Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion
More informationWPS1000 / WPS1000S. Features: EP Series
EP Series WPS000 WPS000S Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates
More informationWPS60 / WPS60S. Features: EP Series
EP Series WPS60 WPS60S Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates
More informationWPS625 / WPS625S. Features: EP Series
EP Series WPS625 WPS625S Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates
More informationWPS1250 / WPS1250S. Features: EP Series
EP Series WPS50 WPS50S Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates
More informationWPS100 / WPS100S. Features: EP Series
Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion
More informationEngine Performance 1500 RPM
CUMMINS ENGINE COMPANY, INC Columbus, Indiana 471 ENGINE PERFORMANCE CURVE Basic Engine Model: QST-G3 Engine Critical Parts List: CPL: 284 Curve Number: FR-188 Date: 23Dec3 Q 1 Displacement :.48 liter
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1760KW MODEL#FDK-CG1760/H1
More informationWPS60/S EP Series. Features:
Features: Rotate speed governor: Mechanical governor Excitation system: self-excited SHUNT A.V.R model: R220/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1320KW MODEL#FDK-CC1320/H1
More informationPRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour
Cummins Inc. Columbus, Indiana 47201 Engine Data Sheet Basic Engine Model: 1-G8 Engine Critical Parts List: CPL: 2816 Curve Number: FR-10302 Date: 3Oct01 1 Displacement : 1 liter (912 in 3 ) Bore : 137
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 660KW MODEL#FDK-CG660/H1
More informationWPS150/S EP Series. Features:
Features: Rotate speed governor: Mechanical governor Excitation system: self-excited A.V.R model: R250/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 550KW MODEL#FDK-CG550/H1
More informationWPS100/S EP Series. Features:
Features: Rotate speed governor: Mechanical governor Excitation system: self-excited A.V.R model: R250/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance
More informationEngine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me
WGP-C30/S CUMMINS Series Rotate speed governor: Mechanical governor Excitation system: Self excited, SHUNT A.V.R model: AS480 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed
More informationWPS20/S EP Series. Features:
Features: Rotate speed governor: Mechanical governor Excitation system: self-excited SHUNT A.V.R model: R220 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance
More informationWPS350/S EP Series. Features:
Features: Rotate speed governor: Electronic Excitation system: self-excited, SHUNT A.V.R model: R250/R450 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-840026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 880KW MODEL#FDK-CG880E/H1
More informationGMS200C/S EC Series. Features:
Features: Rotate speed governor: Electrical governor S6700E Excitation system: Self excited A.V.R model: AS440 Emergency stop switch ATS (automatic transfer switch) receptacle 2xV sealed for life maintenance
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 600KW #FDK-CC600/H2 60HZ/1800RPM
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 800KW MODEL#FDK-CC800/H2
More informationGMS100C/S EC Series. Features:
Features: Rotate speed governor: Mechanical governor Excitation system: Self excited A.V.R model: SX440 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance
More informationGMS350C/S EC Series. Features:
Features: Rotate speed governor: Electircal governor FP801 Excitation system: Self excited, SHUNT A.V.R model: AS440 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life
More informationWPS250/S EP Series. Features:
Features: Rotate speed governor: Electronic Excitation system: self-excited, SHUNT A.V.R model: R250/R450 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance
More informationTriton 80kW. Standy Rating: Triton 80kW. Triton Power Corp 8511 NW 61st Street Miami, FL T: F:
Triton 80kW Standy Rating: Triton 80kW Triton Power Corp 8511 NW 61st Street Miami, FL 33166 T: 305-592-6800 F: 305-592-5900 www.tritonpower.com Cummins Inc. Columbus, Indiana 47201 Engine Data Sheet Basic
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86--8426 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR KW MODEL#FDK-CC/H2 6HZ/18RPM
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-2-8426 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 8KW MODEL#FDK-CG8/H1 HZ/1RPM
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 400KW MODEL#FDK-CC400E/H2
More informationCurve Number: FR Engine Critical Parts List: CPL 2893 Date: 19Jun00. Aspiration : Turbocharged and Aftercooled
Curve Number: FR-90766 Engine Critical Parts List: CPL 2893 Date: 19Jun00 Displacement : 5.88 litre (359.0 in 3 ) Bore : 102 mm (4.02 in.) Stroke : 120 mm (4.72 in.) No. of Cylinders : 6 Aspiration : Turbocharged
More informationMODEL PERFORMANCE. ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... lb ft (N m) 1000 (1356)
CPL INSTALLATION DIAGRAM Engine: Engine With Radiator : GENERAL DATA Type... 4 Cycle; In-line; 6 Cylinder Diesel Aspiration... Turbocharged and Air to Air Aftercooled Bore x Stroke... in x in (mm x mm)
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-2-8426 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 72KW MODEL#FDK-CG72/H1 HZ/1RPM
More informationGKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!
Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 550KVA Generator Set Specification. Ultra Silent, Extended Life! Page - 1 - of 5 3-Phase, 50Hz@1500RPM
More informationGRUPO ELECTROGENO 150 KVA
GRUPO ELECTROGENO 150 KVA 1.- Características Técnicas del Motor. Modelo Sistema de refrigeración Sistema de Admisión Cilindros Sistema Eléctrico Combustible Gobernador CUMMINS Radiador incorporado Filtro
More informationGKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!
Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 660KVA Generator Set Specification NO: GKP660KVA2012 c 2012 The Generator King (Pty) Ltd. Ultra Silent,
More informationS5L1D-G4 Wdg Technical Data Sheet
- Technical Data Sheet Standards STAMFORD industrial alternators meet the requirements of the relevant parts of the IEC EN 60034 and the relevant section of other international standards such as BS5000,
More informationModel: TD200 UCI274J / / /
you can depend on Model: TD Ratings Range 6Hz Standby: kw 17- kva 213- Prime: kw 16-18 kva -2 Standby Rating Prime Rating Generator Voltage PH Hz kw/kva Amps kw/kva Amps Shown with optional equipment Features
More informationHCI634H - Winding 311 and 312. Technical Data Sheet
HCI634H - Winding 311 and 312 Technical Data Sheet HCI634H SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international
More informationD09. 6 Advertised BHP 343 (460) 2100
CUMMINS ENGINE COMPANY, INC Columbus, Indiana 47202-3005 ENGINE PERFORMANCE CURVE Basic Engine Model: Curve Number: -C460 FR-1914 Engine Family: CPL Code: Date: D09 1921 19Jan95 Construction 1 Displacement:
More informationHCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet
- Winding 311 and 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationP734H - Technical Data Sheet
P734H - Technical Data Sheet Standards STAMFORD industrial alternators meet the requirements of the relevant parts of the BS EN 60034 and the relevant section of other international standards such as BS5000,
More informationHCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet
HCI634J - Winding 311 and 312 Technical Data Sheet HCI634J SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international
More informationHCI634H - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet
HCI634H - Winding 311 and 312 Technical Data Sheet HCI634H SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international
More informationHCI634G - Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000,
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1320KW MODEL#FDK-MIT1320/H1
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1540KW MODEL#FDK-MIT1540/H1
More informationUCI274H - Technical Data Sheet Winding 06
- Technical Data Sheet Winding 06 SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationHCM634K - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet
- Winding 311 and 312 Technical Data Sheet SPECIFICATIONS & OPTIONS WINDING 311 and 312 STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: www.fdkenergy.com Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 33KW
More informationHCI634H - Technical Data Sheet
HCI634H - Technical Data Sheet HCI634H SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationUCI274C - Technical Data Sheet Winding 06
- Technical Data Sheet Winding 06 SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationPI734G - Winding 312. Technical Data Sheet APPROVED DOCUMENT
- Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards
More information(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with
SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1100KW MODEL#FDK-MIT1100/H1
More informationPI736F - Winding 312. Technical Data Sheet
PI736F - Winding 312 Technical Data Sheet PI736F SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
More informationUCI224F - Winding 14. Technical Data Sheet APPROVED DOCUMENT
UCI224F - Winding 14 Technical Data Sheet UCI224F SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international
More informationUCI274E - Winding 14 APPROVED DOCUMENT. Technical Data Sheet
UCI274E - Winding 14 Technical Data Sheet UCI274E SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international
More informationHCM534D - Winding 14 APPROVED DOCUMENT. Technical Data Sheet
- Winding 14 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards
More informationHCM434E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT
HCM434E - Winding 311 Single Phase Technical Data Sheet HCM434E SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd
More informationUCM274E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT
UCM274E - Winding 311 Single Phase Technical Data Sheet UCM274E SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd
More informationHCI 534E/544E - Technical Data Sheet
HCI 34E/44E - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationHCI 434E/444E - Technical Data Sheet
HCI 434E/444E - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationUCM224D - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT
UCM224D - Technical Data Sheet UCM224D SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other
More informationHCI434C/444C - Winding 17 APPROVED DOCUMENT. Technical Data Sheet
- Winding 17 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 34 and the relevant section of other international
More informationUCI224F - Winding 25. Technical Data Sheet APPROVED DOCUMENT
- Winding 25 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as
More informationUCI224E - Winding 06. Technical Data Sheet APPROVED DOCUMENT
- Winding 06 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as
More informationUCI274E - Winding 06 APPROVED DOCUMENT. Technical Data Sheet
- Winding 06 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as
More informationUCI224C - Winding 06. Technical Data Sheet APPROVED DOCUMENT
UCI224C - Winding 06 Technical Data Sheet UCI224C SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international
More informationUCDI224E - Technical Data Sheet
UCDI224E - Technical Data Sheet UCDI224E SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationUCM274E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
UCM274E - Winding 311 Technical Data Sheet UCM274E SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd
More informationPI044G - Winding 06 APPROVED DOCUMENT. Technical Data Sheet
- Winding 06 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international
More informationPI144J - Winding 05 APPROVED DOCUMENT. Technical Data Sheet
- Winding 05 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international
More informationUCM274C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
UCM274C - Winding 311 Technical Data Sheet UCM274C SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd
More informationUCI274D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
UCI274D - Winding 311 Technical Data Sheet UCI274D SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE Stamford industrial generators meet the requirements of BS EN 60034 and the relevant
More informationHCM534F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
- Winding 311 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and certifications
More informationPI044D - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE
More informationPI144G - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE
More informationPI044H - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE
More informationPI044F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE
More informationPI044E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE
More informationPI144E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE
More informationPI144F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE
More informationUCI224E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This Stamford industrial generators meet the requirements of eliminates
More informationUCI224F - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This Stamford industrial generators meet the requirements of eliminates
More informationPM734E - Winding 28. Technical Data Sheet APPROVED DOCUMENT
- Winding 28 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and certifications
More informationUCI224G - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
- Winding 311 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other
More informationUCDI274J - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
UCDI274J - Winding 311 Technical Data Sheet UCDI274J SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE Stamford industrial generators meet the requirements of BS EN 60034 and the relevant
More informationPI144D - Winding 17. Technical Data Sheet APPROVED DOCUMENT
PI144D - Winding 17 Technical Data Sheet PI144D SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 34 and the relevant section of other international standards
More informationLVI634E - Technical Data Sheet
LVI634E - Technical Data Sheet LVI634E SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationUCI224E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
UCI224E - Winding 311 Technical Data Sheet UCI224E SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE Stamford industrial generators meet the requirements of BS EN 60034 and the relevant
More informationBCI164C - Technical Data Sheet Winding 06
- Technical Data Sheet Winding 06 SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationUCDI274J - Technical Data Sheet
UCDI274J - Technical Data Sheet UCDI274J SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationUCI274H - Technical Data Sheet
UCI274H - Technical Data Sheet UCI274H SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationHCI434E/444E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet
HCI434E/444E - Technical Data Sheet HCI434E/444E SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This Stamford industrial generators meet
More informationHCI534F/544F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet
HCI34F/44F - Technical Data Sheet HCI34F/44F SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This Stamford industrial generators meet
More informationUCI224C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
UCI224C - Winding 311 Technical Data Sheet UCI224C SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE Stamford industrial generators meet the requirements of BS EN 60034 and the relevant
More informationUCI224D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS
UCI224D - Winding 311 Technical Data Sheet UCI224D SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE Stamford industrial generators meet the requirements of BS EN 60034 and the relevant
More informationUCI274D - Technical Data Sheet
UCI274D - Technical Data Sheet UCI274D SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationPPU Diesel Power 50/60Hz Containerized Generator Set
50Hz at 0.8 Power Factor 380-400V 3-Phase Rated Voltage 60Hz at 0.8 Power Factor 480V 3-Phase Rated Voltage PRIME STANDBY 800kW/1,000kVA 880kW/1,100kVA GENERATOR SET PERFORMANCE Application A factory designed
More information