GMS450C / GMS450CS. Features: EC Series

Size: px
Start display at page:

Download "GMS450C / GMS450CS. Features: EC Series"

Transcription

1 Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion resistance Vibration isolators between the engine/alternator and base frame Integrated wiring design Base fuel tank for at least 8 hours running Equipped with an industrial muffler Engine oil pump 50 radiator Top lifting and steel base frame with forklift holes Drainage for fuel tank Complete protection functions and safety labels IP54 (soundproof sets), IP56 (control system) Water jacket preheater, oil heater and double air cleaner, etc. are available. Output Ratings Generating Set Model Prime Standby GMS450C/S 450kVA/360kW 495kVA/396kW Ratings at 0.8 power factor. Ratings and Performance Data Dimensions and Weights Engine Make & Model: KTA19-G3 Generating Set Model Length (L) mm (in) Width (W) mm (in) Height (H) mm (in) Dry kg (lb) Alternator Model: Alternator Brand: Control System: HCI544C STAMFORD PLC-920 / PLC-7420 GMS450C GMS450CS Dry = With Lube Oil Wet = With Lube Oil and Coolant Noise Level@7m: Frequency & Phase: 50Hz & 3PH Engine Speed: RPM 1500 Structure Type: Fuel Tank Capacity: L Fuel Consumption: l/hr (100% Load) GMS450C GMS450CS GMS450C GMS450CS Prime Standby A R Also available in the following voltages: 415/240V-380/220V-220/127V-200/115V; ESP: Standby Power Standby duty, operation under variable load, without over load; PRP: Prime Power-Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 hours; The data is only for your reference but not for use of sales. M: Mechanical speed governor, E/ECU: Electronic speed governor; NA: Naturally aspirated, TC: Turbocharged, TCA: Turbocharged and air-air aftercooled. TCW: Water-cooled Turbocharged; The weights are approximate and without fuel

2 Engine model: KTA19-G3 GENERAL ENGINE DATA Type... 4-Cycle; In-line; 6-Cylinder Diesel Aspiration... Turbochar ged and A ftercooled Bore x Stroke... in x in (mm x mm) 6.25 x 6.25 (159 x 159) Displacement... in 3 (liter) 1150 (18.9) Compression Ratio : 1 Dry Weight Fan to Flywheel Engine... lb (kg) 4000 (1814) Heat Exchanger Cooled Engine... lb (kg) 4421 (2005) Wet Weight Fan to Flywheel Engine... lb (kg) 4159 (1886) Heat Exchanger Cooled Engine... lb (kg) 4723 (2142) Moment of Inertia of Rotating Components with FW 4001 Flywheel... lb m ft 2 (kg m 2 ) 170 (7.2) with FW 4006 Flywheel... lb m ft 2 (kg m 2 ) 199 (8.4) Center of Gravity from Rear Face of Flywheel Housing (FH 4018)... in (mm) 28.4 (721) Center of Gravity Above Crankshaft Centerline... in (mm) 9.0 (229) Maximum Static Loading at Rear Main Bearing... lb (kg) 2000 (908) ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... lb ft (N m) 1000 (1356) EXHAUST SYSTEM Maximum Back Pressure... in Hg (mm Hg) 3 (76) AIR INDUCTION SYSTEM Maximum Intake Air Restriction with Dirty Filter Element... in H 2 O (mm H 2 O) 25 (635) with Normal Duty Air Cleaner and Clean Filter Element... in H 2 O (mm H 2 O) 10 (254) with Heavy Duty Air Cleaner and Clean Filter Element... in H 2 O (mm H 2 O) 15 (381) COOLING SYSTEM Coolant Capacity Engine Only... US gal (liter) 8.0 (30) with HX 4073 Heat Exchanger... US gal (liter) 17.5 (66) Maximum Coolant Friction Head External to Engine 1800 rpm... psi (kpa) 10 (69) 1500 rpm... psi (kpa) 8 (55) Maximum Static Head of Coolant Above Engine Crank Centerline... ft (m) 60 (18.3) Standard Thermostat (Modulating) Range... F ( C) (82-93) Minimum Pressure Cap... psi (kpa) 10 (69) Maximum Top Tank Temperature for Standby / Prime Power... F ( C) 220 / 212 (104 / 100) Minimum Raw Water 90 F to HX 4073 Heat Exchanger... US gpm (liter / min) 54 (204) Maximum Raw Water Inlet Pressure at HX 4073 Heat Exchanger... psi (kpa) 50 (345) LUBRICATION SYSTEM Oil Idle Speed... psi (kpa) 20 Governed Speed... psi (kpa) ( ) Maximum Oil Temperature... F ( C) 250 (121) Oil Capacity with OP 4019 Oil Pan : High - Low... US gal (liter) (38-32) Total System Capacity (Including Bypass Filter)... US gal (liter) 13.2 (50) Angularity of OP 4019 Oil Pan Front Down Front Up Side to Side... 30

3 Engine model: KTA19-G3 FUEL SYSTEM Type Injection System... Direct Injection Cummins PT Maximum Restriction at PT Fuel Injection Pump with Clean Fuel Filter... in Hg (mm Hg) 4.0 (102) with Dirty Fuel Filter... in Hg (mm Hg) 8.0 (203) Maximum Allowable Head on Injector Return Line (Consisting of Friction Head and Static Head)... in Hg (mm Hg) 6.5 (165) Maximum Fuel Flow to Injection Pump... US gph (liter / hr) 60 (227) ELECTRICAL SYSTEM Cranking Motor (Heavy Duty, Positive Engagement)... volt 24 Battery Charging System, Negative Ground... ampere 35 Maximum Allowable Resistance of Cranking Circuit... ohm Minimum Recommended Battery Capacity Cold 50 F (10 C) and Above... 0 F CCA 600 Cold 32 F to 50 F (0 C to 10 C)... 0 F CCA 640 Cold 0 F to 32 F (-18 C to 0 C)... 0 F CCA 900 PERFORMANCE DATA All data is based on: Engine operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer; not included are battery charging alternator, fan, and optional driven components. Engine operating with fuel corresponding to grade No. 2-D per ASTM D975. ISO 3046, Part 1, Standard Reference Conditions of: Barometric Pressure : 100 kpa (29.53 in Hg) Air Temperature : 25 C (77 F) Altitude : 110 m (361 ft) Relative Humidity : 30% Steady State Stability Band at any Constant Load... % +/ Estimated Free Field Sound Pressure Level of a Typical Generator Set; Excludes Exhaust Noise; at Rated Load and 7.5 m (24.6 ft); 1800 rpm / 1500 rpm... dba N.A. Exhaust Noise at 1 m Horizontally from Centerline of Exhaust Pipe Outlet Upwards at dba N.A. STANDB Y POWER PRIME POWER 60 hz 50 hz 60 hz 50 hz Governed Engine Speed... rpm Engine Idle Speed... rpm Gross Engine Power Output... BHP (kw m ) 685 (511) 600 (448) 620 (463) 540 (403) Brake Mean Effective Pressure... psi (kpa) 262 (1806) 275 (1896) 237 (1634) 248 (1710) Piston Speed... ft / min (m / s) 1875 (9.5) 1562 (7.9) 1875 (9.5) 1562 (7.9) Friction Horsepower... HP (kw m ) 85 (63) 60 (45) 85 (63) 60 (45) Engine Water Flow at Stated Friction Head External to Engine: 3 psi Friction Head... US gpm (liter / s) 196 (12.4) 162 (10.2) 196 (12.4) 162 (10.2) Maximum Friction Head... US gpm (liter / s) 175 (11.0) 145 (9.1) 175 (11.0) 145 (9.1) Engine Data with D ry Type Exhaust M anifold Intake Air Flow... cfm (liter / s) 1370 (647) 1130 (533) 1295 (611) 1030 (486) Exhaust Gas Temperature... F ( C) 915 (491) 990 (532) 880 (471) 975 (524) Exhaust Gas Flow... cfm (liter / s) 3630 (1713) 3155 (1489) 3345 (1579) 2850 (1345) Air to Fuel Ratio... air : fuel 26.4 : : : : 1 Radiated Heat to Ambient... BTU / min (kw m ) 4185 (74) 3665 (64) 3805 (67) 3315 (58) Heat Rejection to Coolant... BTU / min (kw m ) (313) (274) (283) (247) Heat Rejection to Exhaust... BTU / min (kw m ) (328) (287) (302) (263)

4 Alternator model: HCI544C CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G. A.V.R. MX321 MX341 VOLTAGE REGULATION ± 0.5 % ± 1.0 % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) CONTROL SYSTEM SELF EXCITED A.V.R. AS440 VOLTAGE REGULATION ± 1.0 % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT INSULATION SYSTEM PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS STATOR WDG. RESISTANCE ROTOR WDG. RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE R.F.I. SUPPRESSION WAVEFORM DISTORTION MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR WR² INERTIA SHIPPING WEIGHTS in a crate PACKING CRATE SIZE CLASS H IP DOUBLE LAYER LAP TWO THIRDS Ohms PER PHASE AT 22 C SERIES STAR CONNECTED 17 Ohms at 22 C Ohms PER PHASE AT 22 C BS EN & BS EN ,VDE 0875G, VDE 0875N. refer to factory for others NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% 1 BEARING 1263 kg 584 kg 502 kg kgm kg 166 x 87 x 124(cm) 50 Hz 1.55 Ohms at 22 C 2250 Rev/Min BALL (ISO) BALL (ISO) 2 BEARING 1275 kg 584 kg 473 kg kgm kg 166 x 87 x 124(cm) TELEPHONE INTERFERENCE THF<2% TIF<50 COOLING AIR VOLTAGE SERIES STAR 380/ m³/sec 400/ cfm 415/ / / m³/sec 440/ cfm 460/ /277 VOLTAGE PARALLEL STAR 190/ / / / / / / /138 VOLTAGE SERIES DELTA 220/ / / / / / / /138 kva BASE RATING FOR REACTANCE VALUES Xd DIR. AXIS SYNCHRONOUS X'd DIR. AXIS TRANSIENT X''d DIR. AXIS SUBTRANSIENT Xq QUAD. AXIS REACTANCE X''q QUAD. AXIS SUBTRANSIENT XL LEAKAGE REACTANCE X2 NEGATIVE SEQUENCE X0 ZERO SEQUENCE REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO 0.08s 0.012s 2s 0.017s 1/Xd 60 Hz

5 Control System function list Control System PLC-920 (Optional) PowerLink PLC-920 generator controllers integrating digital, intelligent and network techniques are used as the automatic control systems for diesel generators. It can carry out functions including pre-alarm, warning & electrical trip, fail monitoring and controls etc. FEATURES Parameter configuration via RS-232 serial communication; Log last 50 events & alarm information with measured values; Statistics records; Remote start/stop; Speed sensing from alternator voltage or magnetic pickup; Configurable 3 inputs and 6 outputs; ECU powers, ECU stop, STOP or fuel solenoid selection; Automatic transfer switching control and engine control; Adjustable start, load and stop timers. SPECIFICATION Dimensions: 111mm*81mm*61mm Protection: IP65 at front panel Operating temperature: -20 to 70 Max. Operating current is 360mA Sender measurement: 0 to 1300 ohm FUNCTION Pre-Alarm Engine temperature Oil pressure Over/under voltage Over/under frequency Over/under speed Warning & Electrical trip Over current Short circuit Error Over/under speed Speed loss Battery low Battery high Maintenance Over current Short circuit Engine stop Can bus Charge alternator Panel cut-out: 81mm*70mm Weight: approximately 0.3kg DC battery supply voltage: 8 to 32Vdc CT secondary: 5A Accuracy: 1%FS, resolution: 1 ohm Fail monitoring Emergency stop Multiple engage fail Failed to start Low oil pressure High temperature Speed failure Voltage Charging fail Shutdown Warning Controls Fuel and stop solenoid ECU power and stop Starter motor Automatic generator start Preheat External alarm horn Engine cooling Idle mode General accessory Operator Interface Measurement and Instrumentation Shutdown Protection and Indication Threshold Warning&Indication Paralleling Capability Power Transfer Function Environment Monitoring Function MODEL AVR Electronic Governing Glow plug control Cycle Cranking MODBUS Networking Fault History manual start/stop Auto/remote start Regular Test Auto operation LED Manual operation LED Common Shutdown LED Common warning LED Fail to start LED Emergency stop(local) Alphanumeric screen Remote start input active LED Alarm reset Oil pressure Water Temperture Engine Speed Engine Engine Altamator Altamator Mains Expression Hours Run Number of Starts Battery Voltage Coolant Temperature 3PhaseL-L Voltage&Frequency 3phase Current Frequency kwh Apparent Power Active Power and Reactive Power Power Factor Per PhasekW, kwr Per Phase kva Phase Voltage Output Power Grid Line Voltage Grid Phase Voltage Grid Frequency Low Fuel Level High Fuel Level Low Oil Pressure High Water Temperature Failure to Stop Failure to Start Controlable start circles/times Overspeed Under&Over Voltage Under&Over Frequency Overcurrent Earth Leakage Reverse Power Reverse kwr Low Oil Pressure Low Water Temperature High Water Temperature Low Water Level Low/High Battery Voltage Failure to Charge Overcurrent Overload Genset Under/Over Voltage Genset Under/Over Frequency under/over Speed High Engine Temperature Earth Leakage Synchroscope(Independent Bus) Active and Reactive Power Control Synchroscope(Shared Bus) Synchronization Dector Peak Lopping Automatic Transfer Hard Closed Transition Soft Closed Transtion Gen/Mains Breaker Gen/Mains Breaker Status Protection Speed/Voltage Control Power Indication Fuel&solenoid Valve Control Startor Control Preheating Mains Transfer Switch (Standard) Mains Transfer Switch (Emergency) Operating Temperature ( ) Ambient Temperature ( ) Humidity 80% Grid Over/Under Voltage Control Grid Over/Under Frequency Control Remote Start Output(Load/No-load) Optional Relay Output Remote Telecom Control with All Functions Engine Instrument Monitoring Altemator Output Instrument Monitoring Connection Point with All-around Setting For 6 Users 3 Users Input Connection Point LCD Light Control of Low Light Operation Environment Safe PIN Code RS232/485 Interface Language Selection Multi-Language Function PLC-920 PLC-7420 Standard Optional Impossible

6 Control System Digital, intelligent control system allows easier operation. PLC-7420 FEATURES Microprocessor control, with high stability and credibility Monitoring and measuring operational parameters of the mains supply and genset Indicating operation status, fault conditions, all parameters and alarms Multiple protections; multiple parameters display, like pressure, temp. etc. Manual, automatic and remote work mode selectable Real time clock for time and date display, overall runtime display, 250 log entries Overall power output display Integral speed/frequency detecting, telling status of start, rated operation, overspeed etc. Communication with PC via RS485 OR RS232 interface, using MODBUS protocol PLC-7420 is an advanced control module based on micro-processor, containing all necessary functions for protection of the genset and the breaker control. It can monitor the mains supply, breaker control. and automatically start the engine when the mains is abnormal. Accurately measure various operational parameters and display all values and alarms information on the LCD. In addition, the control module can automaticallyshut down the engine and indicate the engine failure.

7 Optional Engine Alternator Generator Set Fuel System Canopy Water Jacket Preheater Oil Preheater Winding Temperature Measuring Instrument Alternator Preheater PMG Anti-damp and anti-corrosion treatment Anti-condensation heater Tools with the machine Low fuel level alarm Automatic fuel feeding system Fuel T-valves Trailer Lubricating System Exhaust System Cooling System Control Panel Voltages Oil with the machine Protection board from hotness Front heat protection Coolant (-30 C) Remote control panel PLC-920 PLC-7420 ATS 415/240V 400/230V 380/220V 220/127V V PowerLink reserves the right to make changes in model, technical sepcification, color, configuration and accessories without prior notice. Please contact the salesman before ordering. EC Series / May.2013

8 Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion resistance Vibration isolators between the engine/alternator and base frame Integrated wiring design Base fuel tank for at least 8 hours running Equipped with an industrial muffler Engine oil pump 50 radiator Top lifting and steel base frame with forklift holes Drainage for fuel tank Complete protection functions and safety labels IP54 (soundproof sets), IP56 (control system) Water jacket preheater, oil heater and double air cleaner, etc. are available. Output Ratings Generating Set Model Prime Standby GMS450C/S N/A 450kVA/360kW Ratings at 0.8 power factor. Ratings and Performance Data Dimensions and Weights Engine Make & Model: NTTA855-G7A Generating Set Model Length (L) mm (in) Width (W) mm (in) Height (H) mm (in) Dry kg (lb) Alternator Model: Alternator Brand: Control System: HCI544C STAMFORD PLC-920 / PLC-7420 GMS450C GMS450CS Dry = With Lube Oil Wet = With Lube Oil and Coolant Noise Level@7m: Frequency & Phase: 50Hz & 3PH Engine Speed: RPM 1500 Structure Type: Fuel Tank Capacity: L Fuel Consumption: l/hr (100% Load) GMS450C GMS450CS GMS450C GMS450CS Prime Standby A R Also available in the following voltages: 415/240V-380/220V-220/127V-200/115V; ESP: Standby Power Standby duty, operation under variable load, without over load; PRP: Prime Power-Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 hours; The data is only for your reference but not for use of sales. M: Mechanical speed governor, E/ECU: Electronic speed governor; NA: Naturally aspirated, TC: Turbocharged, TCA: Turbocharged and air-air aftercooled. TCW: Water-cooled Turbocharged; The weights are approximate and without fuel

9 Engine model: NTAA855-G7A GENERAL ENGINE DATA Type Aspiration Bore x Stroke - in. in. (mm mm) Displacement - in.3(l) Compression Ratio Firing Order Dry Weight --Engine Only - lb. (kg) Wet Weight --Engine Only - lb. (kg) Moment of Inertia of Rotating Components - With FW1109 flywheel - lb. ft.2 (kg m Center of Gravity from Rear Face of Flywheel Housing - in.(mm) Center of Gravity Above Crankshaft Centerline - in.(mm) ENGINE MOUNTING Maximum Allowable Bending Moment at Rear Face of Block - lb. ft. (N m) EXHAUST SYSTEM Maximum Allowable Back Pressure - in.hg (kpa) Standard Exhaust Pipe Diameter - in. (mm) AIR INDUCTION SYSTEM Maximum Allowable Intake Air Restriction --With Clean Filter Element - in. H2O (kpa) --With Dirty Filter Element - in. H2O (kpa) Maximum Intake Pressure Fall from Turbo to Intake Manifold - PSI (kpa) Maximum Intake Manifold Temperature Rise - F ( C) Minimum Dirt Holding Capacity - g/cfm ( g/l/s ) Maximum Allowable Intake Air Temperature T - F ( C) COOLING SYSTEM Coolant Capacity - Engine Only - U.S. gal (L).. - With Radiator - U.S. gal (L) Maximum Coolant Friction Head External to Engine - PSI (kpa) Maximum Static Head of Coolant (exclusive of Pressure Cap) - PSI (kpa) Maximum Static Head of Coolant Above Engine Crank Centerline -ft. (m) Standard Thermostat (Modulating) Range - F ( C) Minimum Allowable Pressure Cap -PSI (kpa) Maximum Coolant Temperature - F ( C) Maximum Top Tank Temperature - F ( C) Minimum Top Tank Temperature - F ( C) Minimum Coolant Expansion Space - % of System Capacity Minimum Coolant Makeup Capacity - U.S. gal (L).. LUBRICATION SYSTEM Oil Idle Speed - PSI Governed Speed - PSI (kpa) Maximum Allowable Oil Temperature - F ( C) Maximum Oil Consumption - U.S.qt./h (L/h) Oil Pan Capacity - Low / High - U.S. gal. (L) Total System Capacity - U.S. gal. (L) Angularity of Oil Pan - Front Down/Front Up/Side to Side FUEL SYSTEM Type Injection System Maximum Allowable Restriction to Fuel Pump -- With Clean Fuel Filter - in.hg (kpa) -- With Dirty Fuel Filter - in.hg (kpa) Maximum Allowable Head on Injector Return Line -- With Check Valve - in.hg (kpa) 4-Cycle;In-line; 6-Cylinder Turbocharged, Air-Air Cooled ( ) 855 ( 14 ) 14.0: ( 1270 ) 2910 ( 1320 ) ( 4.99 ) 27.7 ( 704 ) 5.5 ( 140 ) 1000 ( 1356 ) 3.0 ( 10 ) 5.0 ( 127 ) 15 ( 3.74 ) 25 ( 6.22 ) 5.0 ( 17 ) 43 ( 24 ) 25 ( 53 ) 30 ( 17 ) 5.5 ( 20.8 ) 16.0 ( 60.6 ) 6 ( 41 ) 15 ( 103 ) 46 ( 14.0 ) ( ) 7.0 (48.2 ) 205 ( 96 ) 212 ( 100 ) 160 ( 71 ) ( 4.2 ) 15Min ( 103 ) Min ( ) 250 ( 121 ) 0.25 ( 0.24 ) 7.5/9.5 ( 28.4 / 36.0 ) 10.2 ( 38.6 ) 38 /38 /38 Direct Injection Cummins PT 4.0 ( 13.5 ) 8.0 ( 27.1 ) 6.5 ( 22.0 )

10 Engine model: NTAA855-G7A -- Without Check Valve - in.hg (kpa) Minimum Fuel Supply Line Size - in. (mm) Minimum Fuel Return Line Size - in. (mm) Maximum Fuel Pump Supply - U.S.gal/h (L) Fuel Rail Pressure - PSI (kpa) Maximum Fuel Temperature F ( C) ELECTRICAL SYSTEM Minimum Recommended Battery Capacity ( 24V ) -- Cold Soak (No Load) - CCA... - Minimum Reserved Capacity - CCA Cold Soak (With Load) - CCA... - Minimum Reserved Capacity - CCA... Maximum Allowable Resistance of Cranking Circuit - ohm Standard Cranking Motor (Heavy Duty, Positive Engagement) - volt Standard Battery Charging System, Negative Ground - ampere PERFORMANCE DATA Idle Speed - r/min Maximum No-Load Governed Speed - r/min Maximum over Speed Capability - r/min Minimum Crankshaft Rotation for unaided Cold Start -r/min Minimum Torque for unaided Cold Start - lb. ft. (N m) Exhaust Sound Pressure at 1m from Exhaust Outlet -1500r/min -dba All data is based on : N/A (8.5) (16) (13) (426) (1196) (71) (509) --Engine Operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer, fan, and optional driven components. --Engine operating with fuel corresponding to grade No.2-D per ASTM D ISO 3046, Part1, Standard Reference Conditions of : Barometric Pressure:100kPa(29.5in.Hg); Altitude: 110m (361ft.); Air Temperature: 25 C (77 F) ; Relative Humidity: 30%. --This Data Sheet includes both air-cooled (Fan/Radiator) & raw water cooled (Heatexchanger/Raw Water Pump) type engine. N.A. 50Hz Governed Engine Speed - r/min 1500 Gross Engine Power Output - HP (kw) 545 (407) Torque lb. ft. (N m) 1911 (2591) Brake Mean Effective Pressure - PSI (kpa) 337 (2326) Piston Speed - ft./min (m/s) 1500 (7.62) Friction Horsepower - HP (kw) 30 (22) Intake Air Flow - CFM (L/s) 1164 (549) Engine Water Flow - GPM (L/min.) 79 (5 ) Raw Water Flow - GPM (L/s) 54 (3.4 ) Fuel Consumption - U.S.gal/h (L/h) 28.5 (108 ) Oil Flow - GPM (L/s) 35 (2.2 ) Exhaust Gas Temperature (After Turbine) - F ( C) 884 ( 473 ) Exhaust Gas Flow (After Turbine) - CFM (L/s) 2619 (1240) Air to Fuel Ratio 24.2 : 1 Heat Radiation - BTU (kw) 2900 (51) Heat Rejection to Coolant - BTU (kw) (305) Heat Rejection to Ambient - BTU (kw) (254)

11 Alternator model: HCI544C CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G. A.V.R. MX321 MX341 VOLTAGE REGULATION ± 0.5 % ± 1.0 % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) CONTROL SYSTEM SELF EXCITED A.V.R. AS440 VOLTAGE REGULATION ± 1.0 % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT INSULATION SYSTEM PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS STATOR WDG. RESISTANCE ROTOR WDG. RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE R.F.I. SUPPRESSION WAVEFORM DISTORTION MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR WR² INERTIA SHIPPING WEIGHTS in a crate PACKING CRATE SIZE CLASS H IP DOUBLE LAYER LAP TWO THIRDS Ohms PER PHASE AT 22 C SERIES STAR CONNECTED 17 Ohms at 22 C Ohms PER PHASE AT 22 C BS EN & BS EN ,VDE 0875G, VDE 0875N. refer to factory for others NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% 1 BEARING 1263 kg 584 kg 502 kg kgm kg 166 x 87 x 124(cm) 50 Hz 1.55 Ohms at 22 C 2250 Rev/Min BALL (ISO) BALL (ISO) 2 BEARING 1275 kg 584 kg 473 kg kgm kg 166 x 87 x 124(cm) TELEPHONE INTERFERENCE THF<2% TIF<50 COOLING AIR VOLTAGE SERIES STAR 380/ m³/sec 400/ cfm 415/ / / m³/sec 440/ cfm 460/ /277 VOLTAGE PARALLEL STAR 190/ / / / / / / /138 VOLTAGE SERIES DELTA 220/ / / / / / / /138 kva BASE RATING FOR REACTANCE VALUES Xd DIR. AXIS SYNCHRONOUS X'd DIR. AXIS TRANSIENT X''d DIR. AXIS SUBTRANSIENT Xq QUAD. AXIS REACTANCE X''q QUAD. AXIS SUBTRANSIENT XL LEAKAGE REACTANCE X2 NEGATIVE SEQUENCE X0 ZERO SEQUENCE REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO 0.08s 0.012s 2s 0.017s 1/Xd 60 Hz

12 Control System function list Control System PLC-920 (Optional) PowerLink PLC-920 generator controllers integrating digital, intelligent and network techniques are used as the automatic control systems for diesel generators. It can carry out functions including pre-alarm, warning & electrical trip, fail monitoring and controls etc. FEATURES Parameter configuration via RS-232 serial communication; Log last 50 events & alarm information with measured values; Statistics records; Remote start/stop; Speed sensing from alternator voltage or magnetic pickup; Configurable 3 inputs and 6 outputs; ECU powers, ECU stop, STOP or fuel solenoid selection; Automatic transfer switching control and engine control; Adjustable start, load and stop timers. SPECIFICATION Dimensions: 111mm*81mm*61mm Protection: IP65 at front panel Operating temperature: -20 to 70 Max. Operating current is 360mA Sender measurement: 0 to 1300 ohm FUNCTION Pre-Alarm Engine temperature Oil pressure Over/under voltage Over/under frequency Over/under speed Warning & Electrical trip Over current Short circuit Error Over/under speed Speed loss Battery low Battery high Maintenance Over current Short circuit Engine stop Can bus Charge alternator Panel cut-out: 81mm*70mm Weight: approximately 0.3kg DC battery supply voltage: 8 to 32Vdc CT secondary: 5A Accuracy: 1%FS, resolution: 1 ohm Fail monitoring Emergency stop Multiple engage fail Failed to start Low oil pressure High temperature Speed failure Voltage Charging fail Shutdown Warning Controls Fuel and stop solenoid ECU power and stop Starter motor Automatic generator start Preheat External alarm horn Engine cooling Idle mode General accessory Operator Interface Measurement and Instrumentation Shutdown Protection and Indication Threshold Warning&Indication Paralleling Capability Power Transfer Function Environment Monitoring Function MODEL AVR Electronic Governing Glow plug control Cycle Cranking MODBUS Networking Fault History manual start/stop Auto/remote start Regular Test Auto operation LED Manual operation LED Common Shutdown LED Common warning LED Fail to start LED Emergency stop(local) Alphanumeric screen Remote start input active LED Alarm reset Oil pressure Water Temperture Engine Speed Engine Engine Altamator Altamator Mains Expression Hours Run Number of Starts Battery Voltage Coolant Temperature 3PhaseL-L Voltage&Frequency 3phase Current Frequency kwh Apparent Power Active Power and Reactive Power Power Factor Per PhasekW, kwr Per Phase kva Phase Voltage Output Power Grid Line Voltage Grid Phase Voltage Grid Frequency Low Fuel Level High Fuel Level Low Oil Pressure High Water Temperature Failure to Stop Failure to Start Controlable start circles/times Overspeed Under&Over Voltage Under&Over Frequency Overcurrent Earth Leakage Reverse Power Reverse kwr Low Oil Pressure Low Water Temperature High Water Temperature Low Water Level Low/High Battery Voltage Failure to Charge Overcurrent Overload Genset Under/Over Voltage Genset Under/Over Frequency under/over Speed High Engine Temperature Earth Leakage Synchroscope(Independent Bus) Active and Reactive Power Control Synchroscope(Shared Bus) Synchronization Dector Peak Lopping Automatic Transfer Hard Closed Transition Soft Closed Transtion Gen/Mains Breaker Gen/Mains Breaker Status Protection Speed/Voltage Control Power Indication Fuel&solenoid Valve Control Startor Control Preheating Mains Transfer Switch (Standard) Mains Transfer Switch (Emergency) Operating Temperature ( ) Ambient Temperature ( ) Humidity 80% Grid Over/Under Voltage Control Grid Over/Under Frequency Control Remote Start Output(Load/No-load) Optional Relay Output Remote Telecom Control with All Functions Engine Instrument Monitoring Altemator Output Instrument Monitoring Connection Point with All-around Setting For 6 Users 3 Users Input Connection Point LCD Light Control of Low Light Operation Environment Safe PIN Code RS232/485 Interface Language Selection Multi-Language Function PLC-920 PLC-7420 Standard Optional Impossible

13 Control System Digital, intelligent control system allows easier operation. PLC-7420 FEATURES Microprocessor control, with high stability and credibility Monitoring and measuring operational parameters of the mains supply and genset Indicating operation status, fault conditions, all parameters and alarms Multiple protections; multiple parameters display, like pressure, temp. etc. Manual, automatic and remote work mode selectable Real time clock for time and date display, overall runtime display, 250 log entries Overall power output display Integral speed/frequency detecting, telling status of start, rated operation, overspeed etc. Communication with PC via RS485 OR RS232 interface, using MODBUS protocol PLC-7420 is an advanced control module based on micro-processor, containing all necessary functions for protection of the genset and the breaker control. It can monitor the mains supply, breaker control. and automatically start the engine when the mains is abnormal. Accurately measure various operational parameters and display all values and alarms information on the LCD. In addition, the control module can automaticallyshut down the engine and indicate the engine failure.

14 Optional Engine Alternator Generator Set Fuel System Canopy Water Jacket Preheater Oil Preheater Winding Temperature Measuring Instrument Alternator Preheater PMG Anti-damp and anti-corrosion treatment Anti-condensation heater Tools with the machine Low fuel level alarm Automatic fuel feeding system Fuel T-valves Trailer Lubricating System Exhaust System Cooling System Control Panel Voltages Oil with the machine Protection board from hotness Front heat protection Coolant (-30 C) Remote control panel PLC-920 PLC-7420 ATS 415/240V 400/230V 380/220V 220/127V V PowerLink reserves the right to make changes in model, technical sepcification, color, configuration and accessories without prior notice. Please contact the salesman before ordering. EC Series / May.2013

GMS1400C / GMS1400CS. Features: EC Series

GMS1400C / GMS1400CS. Features: EC Series Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion

More information

WCS2000 / WCS2000S. Features: WCS Series

WCS2000 / WCS2000S. Features: WCS Series Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion

More information

GMS100C / GMS100CS. Features: EC Series

GMS100C / GMS100CS. Features: EC Series Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion

More information

WPS60 / WPS60S. Features: EP Series

WPS60 / WPS60S. Features: EP Series EP Series WPS60 WPS60S Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates

More information

WPS625 / WPS625S. Features: EP Series

WPS625 / WPS625S. Features: EP Series EP Series WPS625 WPS625S Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates

More information

WPS1000 / WPS1000S. Features: EP Series

WPS1000 / WPS1000S. Features: EP Series EP Series WPS000 WPS000S Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates

More information

WPS100 / WPS100S. Features: EP Series

WPS100 / WPS100S. Features: EP Series Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion

More information

WPS1250 / WPS1250S. Features: EP Series

WPS1250 / WPS1250S. Features: EP Series EP Series WPS50 WPS50S Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates

More information

GMS200C/S EC Series. Features:

GMS200C/S EC Series. Features: Features: Rotate speed governor: Electrical governor S6700E Excitation system: Self excited A.V.R model: AS440 Emergency stop switch ATS (automatic transfer switch) receptacle 2xV sealed for life maintenance

More information

GMS350C/S EC Series. Features:

GMS350C/S EC Series. Features: Features: Rotate speed governor: Electircal governor FP801 Excitation system: Self excited, SHUNT A.V.R model: AS440 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life

More information

GMS100C/S EC Series. Features:

GMS100C/S EC Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: Self excited A.V.R model: SX440 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance

More information

WPS60/S EP Series. Features:

WPS60/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited SHUNT A.V.R model: R220/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life

More information

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me WGP-C30/S CUMMINS Series Rotate speed governor: Mechanical governor Excitation system: Self excited, SHUNT A.V.R model: AS480 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed

More information

WPS150/S EP Series. Features:

WPS150/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited A.V.R model: R250/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information

WPS100/S EP Series. Features:

WPS100/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited A.V.R model: R250/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information

WPS20/S EP Series. Features:

WPS20/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited SHUNT A.V.R model: R220 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information

WPS350/S EP Series. Features:

WPS350/S EP Series. Features: Features: Rotate speed governor: Electronic Excitation system: self-excited, SHUNT A.V.R model: R250/R450 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance

More information

WPS250/S EP Series. Features:

WPS250/S EP Series. Features: Features: Rotate speed governor: Electronic Excitation system: self-excited, SHUNT A.V.R model: R250/R450 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance

More information

Engine Performance 1500 RPM

Engine Performance 1500 RPM CUMMINS ENGINE COMPANY, INC Columbus, Indiana 471 ENGINE PERFORMANCE CURVE Basic Engine Model: QST-G3 Engine Critical Parts List: CPL: 284 Curve Number: FR-188 Date: 23Dec3 Q 1 Displacement :.48 liter

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 600KW #FDK-CC600/H2 60HZ/1800RPM

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 400KW MODEL#FDK-CC400E/H2

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 800KW MODEL#FDK-CC800/H2

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 550KW MODEL#FDK-CG550/H1

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 660KW MODEL#FDK-CG660/H1

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1320KW MODEL#FDK-CC1320/H1

More information

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour Cummins Inc. Columbus, Indiana 47201 Engine Data Sheet Basic Engine Model: 1-G8 Engine Critical Parts List: CPL: 2816 Curve Number: FR-10302 Date: 3Oct01 1 Displacement : 1 liter (912 in 3 ) Bore : 137

More information

Triton 80kW. Standy Rating: Triton 80kW. Triton Power Corp 8511 NW 61st Street Miami, FL T: F:

Triton 80kW. Standy Rating: Triton 80kW. Triton Power Corp 8511 NW 61st Street Miami, FL T: F: Triton 80kW Standy Rating: Triton 80kW Triton Power Corp 8511 NW 61st Street Miami, FL 33166 T: 305-592-6800 F: 305-592-5900 www.tritonpower.com Cummins Inc. Columbus, Indiana 47201 Engine Data Sheet Basic

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86--8426 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR KW MODEL#FDK-CC/H2 6HZ/18RPM

More information

MODEL PERFORMANCE. ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... lb ft (N m) 1000 (1356)

MODEL PERFORMANCE. ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... lb ft (N m) 1000 (1356) CPL INSTALLATION DIAGRAM Engine: Engine With Radiator : GENERAL DATA Type... 4 Cycle; In-line; 6 Cylinder Diesel Aspiration... Turbocharged and Air to Air Aftercooled Bore x Stroke... in x in (mm x mm)

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-2-8426 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 8KW MODEL#FDK-CG8/H1 HZ/1RPM

More information

HCI434C/444C - Winding 17 APPROVED DOCUMENT. Technical Data Sheet

HCI434C/444C - Winding 17 APPROVED DOCUMENT. Technical Data Sheet - Winding 17 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 34 and the relevant section of other international

More information

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet - Winding 311 and 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-840026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 880KW MODEL#FDK-CG880E/H1

More information

HCI634H - Winding 311 and 312. Technical Data Sheet

HCI634H - Winding 311 and 312. Technical Data Sheet HCI634H - Winding 311 and 312 Technical Data Sheet HCI634H SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

HCI 534E/544E - Technical Data Sheet

HCI 534E/544E - Technical Data Sheet HCI 34E/44E - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

HCI 434E/444E - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet HCI 434E/444E - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

HCI634G - Technical Data Sheet

HCI634G - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000,

More information

HCI634H - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI634H - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet HCI634H - Winding 311 and 312 Technical Data Sheet HCI634H SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet HCI634J - Winding 311 and 312 Technical Data Sheet HCI634J SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

Curve Number: FR Engine Critical Parts List: CPL 2893 Date: 19Jun00. Aspiration : Turbocharged and Aftercooled

Curve Number: FR Engine Critical Parts List: CPL 2893 Date: 19Jun00. Aspiration : Turbocharged and Aftercooled Curve Number: FR-90766 Engine Critical Parts List: CPL 2893 Date: 19Jun00 Displacement : 5.88 litre (359.0 in 3 ) Bore : 102 mm (4.02 in.) Stroke : 120 mm (4.72 in.) No. of Cylinders : 6 Aspiration : Turbocharged

More information

HCM634K - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCM634K - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet - Winding 311 and 312 Technical Data Sheet SPECIFICATIONS & OPTIONS WINDING 311 and 312 STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

HCM434E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

HCM434E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT HCM434E - Winding 311 Single Phase Technical Data Sheet HCM434E SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd

More information

UCDI224E - Technical Data Sheet

UCDI224E - Technical Data Sheet UCDI224E - Technical Data Sheet UCDI224E SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1760KW MODEL#FDK-CG1760/H1

More information

UCM274E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCM274E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT UCM274E - Winding 311 Single Phase Technical Data Sheet UCM274E SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd

More information

UCI224F - Winding 25. Technical Data Sheet APPROVED DOCUMENT

UCI224F - Winding 25. Technical Data Sheet APPROVED DOCUMENT - Winding 25 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as

More information

UCI274E - Winding 14 APPROVED DOCUMENT. Technical Data Sheet

UCI274E - Winding 14 APPROVED DOCUMENT. Technical Data Sheet UCI274E - Winding 14 Technical Data Sheet UCI274E SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

UCM224D - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCM224D - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT UCM224D - Technical Data Sheet UCM224D SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other

More information

HCI634H - Technical Data Sheet

HCI634H - Technical Data Sheet HCI634H - Technical Data Sheet HCI634H SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life! Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 550KVA Generator Set Specification. Ultra Silent, Extended Life! Page - 1 - of 5 3-Phase, 50Hz@1500RPM

More information

UCI274H - Technical Data Sheet Winding 06

UCI274H - Technical Data Sheet Winding 06 - Technical Data Sheet Winding 06 SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

UCI224F - Winding 14. Technical Data Sheet APPROVED DOCUMENT

UCI224F - Winding 14. Technical Data Sheet APPROVED DOCUMENT UCI224F - Winding 14 Technical Data Sheet UCI224F SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

UCDI274J - Technical Data Sheet

UCDI274J - Technical Data Sheet UCDI274J - Technical Data Sheet UCDI274J SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

UCM274E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCM274E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet UCM274E - Winding 311 Technical Data Sheet UCM274E SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd

More information

UCI274C - Technical Data Sheet Winding 06

UCI274C - Technical Data Sheet Winding 06 - Technical Data Sheet Winding 06 SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

UCI274H - Technical Data Sheet

UCI274H - Technical Data Sheet UCI274H - Technical Data Sheet UCI274H SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

UCI274D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI274D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet UCI274D - Winding 311 Technical Data Sheet UCI274D SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE Stamford industrial generators meet the requirements of BS EN 60034 and the relevant

More information

UCI224G - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224G - Winding 311 APPROVED DOCUMENT. Technical Data Sheet - Winding 311 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other

More information

UCM274C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCM274C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet UCM274C - Winding 311 Technical Data Sheet UCM274C SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd

More information

UCDI224F - Technical Data Sheet

UCDI224F - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,

More information

UCI224E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCI224E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This Stamford industrial generators meet the requirements of eliminates

More information

HCI 534C/544C - Technical Data Sheet

HCI 534C/544C - Technical Data Sheet HCI 34C/44C - Technical Data Sheet HCI34C/44C SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

PI144D - Winding 17. Technical Data Sheet APPROVED DOCUMENT

PI144D - Winding 17. Technical Data Sheet APPROVED DOCUMENT PI144D - Winding 17 Technical Data Sheet PI144D SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 34 and the relevant section of other international standards

More information

HCM534F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCM534F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet - Winding 311 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and certifications

More information

PI044D - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044D - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE

More information

PI144G - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144G - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE

More information

PI044H - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044H - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE

More information

PI044F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE

More information

PI044E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE

More information

PI144E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE

More information

PI144F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE

More information

UCI274D - Technical Data Sheet

UCI274D - Technical Data Sheet UCI274D - Technical Data Sheet UCI274D SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

UCI224F - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCI224F - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This Stamford industrial generators meet the requirements of eliminates

More information

HCM534D - Winding 14 APPROVED DOCUMENT. Technical Data Sheet

HCM534D - Winding 14 APPROVED DOCUMENT. Technical Data Sheet - Winding 14 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards

More information

UCI224E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet UCI224E - Winding 311 Technical Data Sheet UCI224E SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE Stamford industrial generators meet the requirements of BS EN 60034 and the relevant

More information

UCI274D - Technical Data Sheet

UCI274D - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,

More information

UCI274G - Technical Data Sheet

UCI274G - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,

More information

LVI634E - Technical Data Sheet

LVI634E - Technical Data Sheet LVI634E - Technical Data Sheet LVI634E SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

UCDI274K - Technical Data Sheet

UCDI274K - Technical Data Sheet - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000,

More information

UCDI274J - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCDI274J - Winding 311 APPROVED DOCUMENT. Technical Data Sheet UCDI274J - Winding 311 Technical Data Sheet UCDI274J SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE Stamford industrial generators meet the requirements of BS EN 60034 and the relevant

More information

UCI224C - Technical Data Sheet

UCI224C - Technical Data Sheet UCI224C - Technical Data Sheet UCI224C SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

UCI224C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet UCI224C - Winding 311 Technical Data Sheet UCI224C SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE Stamford industrial generators meet the requirements of BS EN 60034 and the relevant

More information

HCI 434E/444E - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet HCI 434E/444E - Technical Data Sheet HCI434E/444E SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

UCI224D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

UCI224D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS UCI224D - Winding 311 Technical Data Sheet UCI224D SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE Stamford industrial generators meet the requirements of BS EN 60034 and the relevant

More information

P734H - Technical Data Sheet

P734H - Technical Data Sheet P734H - Technical Data Sheet Standards STAMFORD industrial alternators meet the requirements of the relevant parts of the BS EN 60034 and the relevant section of other international standards such as BS5000,

More information

BCI164D - Technical Data Sheet

BCI164D - Technical Data Sheet BCI164D - Technical Data Sheet BCI164D SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

HCI 534F/544F - Technical Data Sheet

HCI 534F/544F - Technical Data Sheet HCI 34F/44F - Technical Data Sheet HCI34F/44F SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

HCI 434D/444D - Technical Data Sheet

HCI 434D/444D - Technical Data Sheet HCI 434D/444D - Technical Data Sheet HCI434D/444D SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

BCI164B - Technical Data Sheet

BCI164B - Technical Data Sheet BCI164B - Technical Data Sheet BCI164B SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

PI044G - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

PI044G - Winding 06 APPROVED DOCUMENT. Technical Data Sheet - Winding 06 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

HCI 534E/544E - Technical Data Sheet

HCI 534E/544E - Technical Data Sheet HCI 34E/44E - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

HCI434E/444E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

HCI434E/444E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet HCI434E/444E - Technical Data Sheet HCI434E/444E SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This Stamford industrial generators meet

More information

HCI534F/544F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

HCI534F/544F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet HCI34F/44F - Technical Data Sheet HCI34F/44F SPECIFICATIONS & OPTIONS STANDARDS WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This Stamford industrial generators meet

More information

PI144J - Winding 05 APPROVED DOCUMENT. Technical Data Sheet

PI144J - Winding 05 APPROVED DOCUMENT. Technical Data Sheet - Winding 05 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

UCDI274K - Technical Data Sheet

UCDI274K - Technical Data Sheet UCDI274K - Technical Data Sheet UCDI274K SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

UCI224F - Technical Data Sheet

UCI224F - Technical Data Sheet UCI224F - Technical Data Sheet UCI224F SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

PI734G - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734G - Winding 312. Technical Data Sheet APPROVED DOCUMENT - Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards

More information

HCI 534E/544E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCI 534E/544E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet HCI 34E/44E - Winding 311 Technical Data Sheet HCI34E/44E SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant

More information

HCI 534C/544C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCI 534C/544C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet HCI 34C/44C - Winding 311 Technical Data Sheet HCI34C/44C SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant

More information

HCI 434F/444F - Technical Data Sheet

HCI 434F/444F - Technical Data Sheet HCI 434F/444F - Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information