(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Size: px
Start display at page:

Download "(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with"

Transcription

1 SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel: Fax: Web: DATA SHEET DIESEL GENERATOR 8KW MODEL#FDK-CG8/H1 HZ/1RPM CUMMINS MODEL: QST3-G3 General Features: All qualified generator sets are subjected to a comprehensive performance test which includes % load, 7% load, 1% load, 11% load and to check, verify that all control systems, alarm and shut-down protection. Equipped with battery charger and 24V high performance maintenance-free lead-acid starting batteries and connecting cables. Stainless galvanized zinc plates with strong corrosion-proof. Vibration isolators between the engine/alternator and base frame. Equipped with industrial silencer and flexible exhaust hose. Designed to comply with ISO828/GB282. Powered by Cummins engine and coupled with Stamford alternator. Water jacket preheater, oil heater and double air cleaner, etc. are available. FDK Diesel Generator Set Data Genset Model FDK-CG8/H1 Engine Make Cummins Original Prime Power 72KW/9KVA Engine Model QST3-G3 Standby Power 8KW/1KVA Alternator model Stamford HCI634H Output Frequency / Rated speed Hz/1rpm Control System DSE732 Rated Voltage 23V/4V Phase Three (1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with ISO828-1.A 1% overload is available for a period of 1 hour within 12-hour period of operation, in accordance with ISO (2) Standby power: The rating is applicable for supplying emergency power in variable load applications for up to 2 hours per year in accordance with ISO Overload is not allowed. (3) Rated voltage: available with customer requirement. Engine Specifications Engine Model (DETAILED in APPENDIX) QST3-G3 Aspiration Turbo-charged Engine Manufacturer Cummins ORIGINAL USA Cylinder quantity 12 Cylinder Arrangement Vee Cycle 4 Bore x Stroke (mm x mm) Displacement 3.48L Compression Ratio 14.:1 Prime power / Speed (KW/RPM) 86kw/1 Standby power/ Speed (KW/RPM) 89kw/1 ISO91:28 FDK reserves the right to change the specifications and designs without noice.

2 Type Injection System Bosch P8 Direct Injection SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel: Fax: Web: Fuel Consumption at 1% load 194 at 1rpm (g/kwh) Piston Speed 9.9m/s Starter motor DC24V Friction Energy Output 82kw Low idle 7-9pm Total Lubrication System Capacity (L) 14 Coolant Capacity (L) 8 Alternator Specifications Alternator model HCI634H Number of phase 3 Alternator manufacturer Exciter type STAMFORD Single bearing, Brushless, Self-excited Rated voltage 4V (Available with custom requirements) Power factor.8 Rated output prime power 94KVA Voltage regulation NL-FL ±1% Rated speed 1 rpm Insulation grade H Rated frequency Hz Protection grade Alternator option: Leroy Somer, MECC, Marathon, Engga, Faraday IP23 Control System DSE732 (DETAILED in INSTRUCTION) DSE732 is an advanced control module based on micro-processor, containing all necessary functions for protection of the genset and the breaker control. It can monitor the mains supply, breaker control and automatically start the engine when the mains are abnormal. Accurately measure various operational parameters and display all values and alarms information on the LCD. In addition, the control module can automatically shut down the engine and indicate the engine failure. FEATURES Microprocessor control, with high stability and credibility. Monitoring and measuring operational parameters of the mains supply and genset. Indicating operation status, fault conditions, all parameters and alarms. Multiple protections; multiple parameters display, like pressure, temp. etc. Manual, automatic and remote work mode selectable. Real time clock for time and date display, overall runtime display, 2 log entries. Overall power output display. Integral speed/frequency detecting, telling status of start, rated operation, overspeed etc. Communication with PC via RS48 OR RS232 interface, using MODBUS protocol. Soundproof Enclosure Specification FDK silent generator is designed by professional acoustic engineers based on years of experience. Now we can make the noise of the generator less than 8-8dB(A) at 1m, or 7-7dB(A) at 7m, 6-6dB(A) at 1m. FEATURES Multi-way air intake and exhaust guarantee the power performance of the generator. Large-scale impedance combined type silencer effectively reduce noise of the generator. Internal high performance rubber damper and flexible materials reduce vibration. Base mounted fuel tank supports the generator running for 8 hours. ISO91:28 FDK reserves the right to change the specifications and designs without noice.

3 SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel: Fax: Web: Optional Generator set Alternator Low environment Temp ATS Open generator set Stamford Water heater CHINT Silent generator set Marathon Oil heater SCHNEIDER Trailer generator set Mecc Alte Battery heater ABB ABB MCCB circuit breaker Leroy Somer Farady Engga Fuel system Control system Voltage Synchronized system 12hrs base tank AMF function 41/24V CHINT Cabinet 24hrs base tank ATS control cabinet 4/23V SCHNEIDER Cabinet Dual wall base fuel tank DSE732 38/22V DSE861 Module Outside fuel tank DSE71 22/127V COMAQ Module GU62A 2/11V DEIF Module Dimension & Weight Open Soundproof Version Overall Size: Overall Size: L W H (mm) L W H (mm) Weight (kg) 74 Weight (kg) 97 Sales Promises FDK provides a full line of brand new and high quality products. Each and every unit is strictly factory tested before shipment. Quality warranty is according to our standard conditions: 12 months from BL date or 1 running hours, whichever comes first. Service and parts are available from FDK or distributors in your location. FDK guarantee use BRAND NEW & GENUINE MACHINE. ISO91:28 FDK reserves the right to change the specifications and designs without noice.

4 CUMMINS ENGINE COMPANY, INC Columbus, Indiana 4721 ENGINE PERFORMANCE CURVE Basic Engine Model: QST3-G3 Engine Critical Parts List: CPL: 284 Curve Number: FR-188 Date: 23Dec3 G-DRIVE Q3 1 Displacement : 3.48 liter (186 in 3 ) Bore : 14 mm (.1 in.) Stroke : 16 mm (6. in.) No. of Cylinders : 12 Aspiration : Turbocharged and Aftercooled Engine Speed Standby Power Prime Power Continuous Power RPM kwm BHP kwm BHP kwm BHP Engine Performance 1 RPM OUTPUT POWER FUEL CONSUMPTION Litre/hour % kwm BHP STANDBY POWER kg/ kwm h lb/ BHP h liter/ hour U.S. Gal/ hour PRIME POWER CONTINUOUS POWER RPM Gross Engine Power Output - kwm CONVERSIONS: (liters = U.S. Gal x 3.78) (kwm = BHP x.746) (U.S. Gal = liters x.2642) (BHP = kwm x 1.34) These guidelines have been formulated to ensure proper application of generator drive engines in A.C. generator set installations. Generator drive engines are not designed for and shall not be used in variable speed D.C. generator set applications. STANDBY POWER RATING Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. Under no condition is an engine allowed to operate in parallel with the public utility at the Standby Power rating. This rating should be applied where reliable utility power is available. A Standby rated engine should be sized for a maximum of an 8% average load factor and 2 hours of operation per year. This includes less than 2 hours per year at the Standby Power rating. Standby ratings should never be applied except in true emergency power outages. Negotiated power outages contracted with a utility company are not considered an emergency. PRIME POWER RATING Applicable for supplying electric power in lieu of commercially purchased power. Prime Power applications must be in the form of one of the following two categories: UNLIMITED TIME RUNNING PRIME POWER Prime Power is available for an unlimited number of hours per year in a variable load application. Variable load should not exceed a 7% average of the Prime Power rating during any operating period of 2 hours. The total operating time at 1% Prime Power shall not exceed hours per year. A 1% overload capability is available for a period of 1 hour within a 12-hour period of operation. Total operating time at the 1% overload power shall not exceed 2 hours per year. LIMITED TIME RUNNING PRIME POWER Limited Time Prime Power is available for a limited number of hours in a non-variable load application. It is intended for use in situations where power outages are contracted, such as in utility power curtailment. Engines may be operated in parallel to the public utility up to 7 hours per year at power levels never to exceed the Prime Power rating. The customer should be aware, however, that the life of any engine will be reduced by this constant high load operation. Any operation exceeding 7 hours per year at the Limited Time Prime Power rating should use the Continuous Power rating. CONTINUOUS POWER RATING Applicable for supplying utility power at a constant 1% load for an unlimited number of hours per year. No overload capability is available for this rating. Data shown above represent gross engine performance capabilities obtained and corrected in accordance with ISO-346 conditions of 1 kpa (29.3 in Hg) barometric pressure [11 m (361 ft) altitude], 2 C (77 F) air inlet temperature, and relative humidity of 3% with No. 2 diesel or a fuel corresponding to ASTM D2. See reverse side for application rating guidelines. The fuel consumption data is based on No. 2 diesel fuel weight at.8 kg/liter (7.1 lbs/u.s. gal). Power output curves are based on the engine operating with fuel system, water pump and lubricating oil pump; not included are battery charging alternator, fan, optional equipment and driven components. TECHNICAL DATA DEPT. NON CERTIFIED

5 G-DRIVE Q3 2 QST3-G3 Derate 1 RPM CURVE NO: FR-188 DATE: 23Dec STANDBY Ambient Temp. ( C/ F) Altitude (m) /122 4/14 3/86 2/77 Reference Standards: BS-14 and DIN-6271 standards are based on ISO-346. Operation At Elevated Temperature And Altitude: PRIME /122 Ambient Temp. ( C/ F) 4/14 3/86 2/77 For sustained operation above these conditions, derate by an additional 1% per m (164 ft), and 1% per 1 o C (18 o F) Altitude (m) 3 /122 Ambient Temp. ( C/ F) Note: Derates shown are based on 1 in H 2 air intake restriction and 2 in Hg exhaust back pressure CONTINUOUS 4/14 3/86 2/ Altitude (m)

6 CUMMINS ENGINE COMPANY, INC Columbus, Indiana 4721 ENGINE PERFORMANCE CURVE Basic Engine Model: QST3-G3 Engine Critical Parts List: CPL: 284 Curve Number: FR-188 Date: 23Dec3 G-DRIVE Q3 3 Displacement : 3.48 liter (186 in 3 ) Bore : 14 mm (.1 in.) Stroke : 16 mm (6. in.) No. of Cylinders : 12 Aspiration : Turbocharged and Aftercooled Engine Speed Standby Power Prime Power Continuous Power RPM kwm BHP kwm BHP kwm BHP Engine Performance 18 RPM OUTPUT POWER FUEL CONSUMPTION U.S. Gallons/hour % kwm BHP STANDBY POWER kg/ kwm h lb/ BHP h liter/ hour U.S. Gal/ hour PRIME POWER CONTINUOUS POWER RPM Gross Engine Power Output - BHP CONVERSIONS: (liters = U.S. Gal x 3.78) (kwm = BHP x.746) (U.S. Gal = liters x.2642) (BHP = kwm x 1.34) These guidelines have been formulated to ensure proper application of generator drive engines in A.C. generator set installations. Generator drive engines are not designed for and shall not be used in variable speed D.C. generator set applications. STANDBY POWER RATING Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. Under no condition is an engine allowed to operate in parallel with the public utility at the Standby Power rating. This rating should be applied where reliable utility power is available. A Standby rated engine should be sized for a maximum of an 8% average load factor and 2 hours of operation per year. This includes less than 2 hours per year at the Standby Power rating. Standby ratings should never be applied except in true emergency power outages. Negotiated power outages contracted with a utility company are not considered an emergency. PRIME POWER RATING Applicable for supplying electric power in lieu of commercially purchased power. Prime Power applications must be in the form of one of the following two categories: UNLIMITED TIME RUNNING PRIME POWER Prime Power is available for an unlimited number of hours per year in a variable load application. Variable load should not exceed a 7% average of the Prime Power rating during any operating period of 2 hours. The total operating time at 1% Prime Power shall not exceed hours per year. A 1% overload capability is available for a period of 1 hour within a 12-hour period of operation. Total operating time at the 1% overload power shall not exceed 2 hours per year. LIMITED TIME RUNNING PRIME POWER Limited Time Prime Power is available for a limited number of hours in a non-variable load application. It is intended for use in situations where power outages are contracted, such as in utility power curtailment. Engines may be operated in parallel to the public utility up to 7 hours per year at power levels never to exceed the Prime Power rating. The customer should be aware, however, that the life of any engine will be reduced by this constant high load operation. Any operation exceeding 7 hours per year at the Limited Time Prime Power rating should use the Continuous Power rating. CONTINUOUS POWER RATING Applicable for supplying utility power at a constant 1% load for an unlimited number of hours per year. No overload capability is available for this rating. Data shown above represent gross engine performance capabilities obtained and corrected in accordance with ISO-346 conditions of 1 kpa (29.3 in Hg) barometric pressure [11 m (361 ft) altitude], 2 C (77 F) air inlet temperature, and relative humidity of 3% with No. 2 diesel or a fuel corresponding to ASTM D2. See reverse side for application rating guidelines. The fuel consumption data is based on No. 2 diesel fuel weight at.8 kg/liter (7.1 lbs/u.s. gal). Power output curves are based on the engine operating with fuel system, water pump and lubricating oil pump; not included are battery charging alternator, fan, optional equipment and driven components. TECHNICAL DATA DEPT. NON CERTIFIED

7 G-DRIVE Q3 4 3 QST3-G3 Derate 18 RPM Ambient Temp. ( C/ F) CURVE NO: FR-188 DATE: 23Dec STANDBY Altitude (ft) Ambient Temp. ( C/ F) /122 4/14 3/86 2/77 Reference Standards: BS-14 and DIN-6271 standards are based on ISO-346. Operation At Elevated Temperature And Altitude: For sustained operation above these conditions, derate by an additional 8% per m (164 ft), and 1% per 1 o C (18 o F) PRIME /122 4/14 3/ Altitude (ft) Note: Derates shown are based on 1 in H 2 air intake restriction and 2 in Hg exhaust back pressure CONTINUOUS /122 Ambient Temp. ( C/ F) 4/14 3/86 2/ Altitude (ft)

8 Cummins Engine Company, Inc. Engine Data Sheet DATA SHEET : DS-188 ENGINE MODEL : QST3-G3 CONFIGURATION NUMBER : D731GX3 DATE : 23Dec3 PERFORMANCE CURVE : FR-188 INSTALLATION DIAGRAM CPL NUMBER Fan to Flywheel : Engine Critical Parts List : 284 G-DRIVE Q3 GENERAL ENGINE DATA Type... 4-Cycle; Vee; 12-Cylinder Diesel Aspiration... Turbocharged and Aftercooled Bore x Stroke... mm x mm (in x in) 14 x16 (.1 x 6.) Displacement... liter (in 3 ) 3.48 (186) Compression Ratio Dry Weight Fan to Flywheel Engine... kg (lb) 2967 (64) Wet Weight Fan to Flywheel Engine... kg (lb) 362 (67) Moment of Inertia of Rotating Components with FW Flywheel... kg m 2 (lb m ft 2 ) 8.7 (26) Center of Gravity from Rear Face of Flywheel Housing (FH 31)... mm (in) 84 (33.3) Center of Gravity above Crankshaft Centerline... mm (in) 19 (7.7) Maximum Static Loading at Rear Main Bearing... kg (lb) 9 (21) ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... N m (lb ft) 31 (2286) EXHAUST SYSTEM Maximum Back Pressure... mm Hg (in Hg) 76 (3.) AIR INDUCTION SYSTEM Maximum Intake Air Restriction with Dirty Filter Element... mm H 2 O (in H 2 O) 63 (2) with Normal Duty Air Cleaner and Clean Filter Element... mm H 2 O (in H 2 O) 24 (1) with Heavy Duty Air Cleaner and Clean Filter Element... mm H 2 O (in H 2 O) 381 (1) COOLING SYSTEM Coolant Capacity Engine Only... liter (US gal) 8 (22.4) Maximum Coolant Friction Head External to Engine 18 rpm... kpa (psi) 69. (1.) 1 rpm... kpa (psi) 48. (7.) Maximum Static Head of Coolant Above Engine Crank Centerline... m (ft) 14 (46) Standard Thermostat (Modulating) Range... C ( F) 82-9 (18-23) Minimum Pressure Cap... kpa (psi) 69. (1) Maximum Top Tank Temperature for Standby / Prime Power... C ( F) 14 / 1 (22 / 212) LUBRICATION SYSTEM Oil Idle Speed... kpa (psi) 166 Governed Speed... kpa (psi) ( ) Maximum Oil Temperature... C ( F) 121 (2) Oil Capacity with OP 133 Oil Pan : High - Low... liter (US gal) (3-3) Total System Capacity (Including Bypass Filter)... liter (US gal) 14 (4.7) Angularity of OP 133 Oil Pan Front Down Front Up... 3 Side to Side... 3

9 FUEL SYSTEM G-DRIVE Type Injection System... Bosch P8 Direct Injection Q3 Maximum Restriction at Lift Pump with Clean Fuel Filter... mm Hg (in Hg) 12 (4) 6 with Dirty Fuel Filter... mm Hg (in Hg) 23 (8) Maximum Allowable Head on Injector Return Line (Consisting of Friction Head and Static Head)... mm Hg (in Hg) 8 (2) Maximum Fuel Flow to Injection Pumps (LB and RB Combined) 18 RPM... liter / hr (US gph) 7 (1) 1 RPM... liter / hr (US gph) (14) Maximum Drain Flow (@ Minimum load) 18 RPM... liter / hr (US gph) (14) 1 RPM... liter / hr (US gph) 3 (14) Maximum Fuel Inlet Temperature... C ( F) 66 (1) ELECTRICAL SYSTEM Cranking Motor (Heavy Duty, Positive Engagement)... volt 24 Battery Charging System, Negative Ground... ampere 3 Maximum Allowable Resistance of Cranking Circuit... ohm.2 Minimum Recommended Battery Capacity Cold 1 C ( C) and Above... F CCA 12 Cold C to 1 C (32 F to F)... F CCA 128 Cold -18 C to C ( F to 32 F)... F CCA 18 COLD START CAPABILITY Minimum Ambient Temperature for Aided (with Coolant Heater) Cold Start within 1 seconds to Rated Speed... C ( F) 1 () Minimum Ambient Temperature for Aided (with Grid Heater) Cold Start... C ( F) -1 (14) Minimum Ambient Temperature for Unaided Cold Start... C ( F) (32) PERFORMANCE DATA All data is based on: Engine operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer; not included are battery charging alternator, fan, and optional driven components. Engine operating with fuel corresponding to grade No. 2-D per ASTM D97. ISO 346, Part 1, Standard Reference Conditions of: Barometric Pressure : 99 kpa (29.3 in Hg) Air Temperature : 2 C (77 F) Altitude : 11 m (361 ft) Relative Humidity : 3% Steady State Stability Band at any Constant Load... % +/-.2 Estimated Free Field Sound Pressure Level of a Typical Generator Set; Excludes Exhaust Noise; at Rated Load and 7. m (24.6 ft); 18 / 1 rpm... dba 96.1 / 93.2 (est.) Exhaust Noise at 1 m Horizontally from Centerline of Exhaust Pipe Outlet Upwards at 4 ; (18 / 1 rpm)... dba / (est.) STANDBY PRIME POWER 6 hz hz 6 hz hz Governed Engine Speed... rpm Engine Idle Speed... rpm Gross Engine Power Output... kw m (BHP) 17 (13) 89 (12) 91 (122) 86 (18) Brake Mean Effective Pressure... kpa (psi) 226 (32) 238 (342) 1993 (289) 2117 (37) Piston Speed... m / s (ft / min) 9.9 (1949) 8.3 (1634) 9.9 (1949) 8.3 (1634) Friction Horsepower... kw m (HP) 82 (11) 8 (78) 82 (11) 8 (78) Engine Water Flow at Stated Friction Head External to Engine: psi Friction Head... liter / s (US gpm) 1. (246) 12. (198) 1. (246) 12. (198) Maximum Friction Head... liter / s (US gpm) 1. (238) 12. (19) 1. (238) 12. (19) Engine Data with Dry Type Exhaust Manifold Intake Air Flow... liter / s (cfm) 127 (269) 93 (198) 119 (22) 86 (183) Exhaust Gas Temperature... C ( F) 481 (897) 63 (146) 464 (867) 41 (1) Exhaust Gas Flow... liter / s (cfm) 328 (694) 272 (7) 3 (636) 243 (1) Air to Fuel Ratio... air : fuel 27.3 : : : : 1 Radiated Heat to Ambient... kw m (BTU / min) 11 (67) 1 (84) 1 (92) 9 (2) Heat Rejection to Coolant... kw m (BTU / min) 49 (2794) 4 (2297) 4 (279) 37 (212) Heat Rejection to Exhaust... kw m (BTU / min) 69 (399) 6 (376) 61 (3489) 8 (3283) N.A. - Data is Not Available N/A - Not Applicable to this Engine TBD - To Be Determined ENGINE MODEL : DATA SHEET : DATE : QST3-G3 DS Dec3 CUMMINS ENGINE COMPANY, INC. Columbus, Indiana CURVE NO. : FR-188

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 660KW MODEL#FDK-CG660/H1

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 550KW MODEL#FDK-CG550/H1

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-840026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 880KW MODEL#FDK-CG880E/H1

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1320KW MODEL#FDK-CC1320/H1

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86--8426 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR KW MODEL#FDK-CC/H2 6HZ/18RPM

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 800KW MODEL#FDK-CC800/H2

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 400KW MODEL#FDK-CC400E/H2

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1760KW MODEL#FDK-CG1760/H1

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 600KW #FDK-CC600/H2 60HZ/1800RPM

More information

Engine Performance 1500 RPM

Engine Performance 1500 RPM CUMMINS ENGINE COMPANY, INC Columbus, Indiana 471 ENGINE PERFORMANCE CURVE Basic Engine Model: QST-G3 Engine Critical Parts List: CPL: 284 Curve Number: FR-188 Date: 23Dec3 Q 1 Displacement :.48 liter

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-2-8426 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 72KW MODEL#FDK-CG72/H1 HZ/1RPM

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: www.fdkenergy.com Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 33KW

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1320KW MODEL#FDK-MIT1320/H1

More information

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour Cummins Inc. Columbus, Indiana 47201 Engine Data Sheet Basic Engine Model: 1-G8 Engine Critical Parts List: CPL: 2816 Curve Number: FR-10302 Date: 3Oct01 1 Displacement : 1 liter (912 in 3 ) Bore : 137

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1540KW MODEL#FDK-MIT1540/H1

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1100KW MODEL#FDK-MIT1100/H1

More information

Triton 80kW. Standy Rating: Triton 80kW. Triton Power Corp 8511 NW 61st Street Miami, FL T: F:

Triton 80kW. Standy Rating: Triton 80kW. Triton Power Corp 8511 NW 61st Street Miami, FL T: F: Triton 80kW Standy Rating: Triton 80kW Triton Power Corp 8511 NW 61st Street Miami, FL 33166 T: 305-592-6800 F: 305-592-5900 www.tritonpower.com Cummins Inc. Columbus, Indiana 47201 Engine Data Sheet Basic

More information

Curve Number: FR Engine Critical Parts List: CPL 2893 Date: 19Jun00. Aspiration : Turbocharged and Aftercooled

Curve Number: FR Engine Critical Parts List: CPL 2893 Date: 19Jun00. Aspiration : Turbocharged and Aftercooled Curve Number: FR-90766 Engine Critical Parts List: CPL 2893 Date: 19Jun00 Displacement : 5.88 litre (359.0 in 3 ) Bore : 102 mm (4.02 in.) Stroke : 120 mm (4.72 in.) No. of Cylinders : 6 Aspiration : Turbocharged

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 176KW MODEL#FDK-P176/H1 50HZ/1500RPM PERKINS MODEL: 1106A-70TAG4 General Features: All qualified generator

More information

GRUPO ELECTROGENO 150 KVA

GRUPO ELECTROGENO 150 KVA GRUPO ELECTROGENO 150 KVA 1.- Características Técnicas del Motor. Modelo Sistema de refrigeración Sistema de Admisión Cilindros Sistema Eléctrico Combustible Gobernador CUMMINS Radiador incorporado Filtro

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 605KW MODEL#FDK-D605/H1

More information

Engine Make. (1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Engine Make. (1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 176KW MODEL#FDK-D176E/H1

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 88KW MODEL#FDK-P88/H1 50HZ/1500RPM

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 18KW MODEL#FDK-P18/H1 50HZ/1500RPM

More information

MODEL PERFORMANCE. ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... lb ft (N m) 1000 (1356)

MODEL PERFORMANCE. ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... lb ft (N m) 1000 (1356) CPL INSTALLATION DIAGRAM Engine: Engine With Radiator : GENERAL DATA Type... 4 Cycle; In-line; 6 Cylinder Diesel Aspiration... Turbocharged and Air to Air Aftercooled Bore x Stroke... in x in (mm x mm)

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 440KW MODEL#FDK-P440/H1

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 2000KW MODEL#FDK-P2000/H1

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 360KW MODEL#FDK-P360/H1

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 580KW MODEL#FDK-P580/H1

More information

Model: TD200 UCI274J / / /

Model: TD200 UCI274J / / / you can depend on Model: TD Ratings Range 6Hz Standby: kw 17- kva 213- Prime: kw 16-18 kva -2 Standby Rating Prime Rating Generator Voltage PH Hz kw/kva Amps kw/kva Amps Shown with optional equipment Features

More information

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me WGP-C30/S CUMMINS Series Rotate speed governor: Mechanical governor Excitation system: Self excited, SHUNT A.V.R model: AS480 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD GUANGZHOU SANQ DIESEL GENERATOR SET CO., LTD Tel:86-13729889887 Fax:86-20-84550026 Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 1320KW MODEL#FDK-P1320/H1

More information

WCS2000 / WCS2000S. Features: WCS Series

WCS2000 / WCS2000S. Features: WCS Series Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion

More information

D09. 6 Advertised BHP 343 (460) 2100

D09. 6 Advertised BHP 343 (460) 2100 CUMMINS ENGINE COMPANY, INC Columbus, Indiana 47202-3005 ENGINE PERFORMANCE CURVE Basic Engine Model: Curve Number: -C460 FR-1914 Engine Family: CPL Code: Date: D09 1921 19Jan95 Construction 1 Displacement:

More information

GMS200C/S EC Series. Features:

GMS200C/S EC Series. Features: Features: Rotate speed governor: Electrical governor S6700E Excitation system: Self excited A.V.R model: AS440 Emergency stop switch ATS (automatic transfer switch) receptacle 2xV sealed for life maintenance

More information

GMS1400C / GMS1400CS. Features: EC Series

GMS1400C / GMS1400CS. Features: EC Series Features: Excitation system: self-excited (AREP and PMG are optional) ATS (automatic transfer switch) receptacle Lockable battery isolator switch Stainless galvanized zinc plates with strong corrosion

More information

GMS100C/S EC Series. Features:

GMS100C/S EC Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: Self excited A.V.R model: SX440 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance

More information

Dongfeng Cummins Techical Operations

Dongfeng Cummins Techical Operations Dongfeng Cummins Techical Operations ENGINE MODEL: 6BT5.9-G2 CURVE & DATASHEET: FR93146 REV 01 15OCT2013 Generator Engine Performance Data DONGFENG CUMMINS ENGINE Co.,LTD Xiangfan, Hubei Province, China

More information

GMS350C/S EC Series. Features:

GMS350C/S EC Series. Features: Features: Rotate speed governor: Electircal governor FP801 Excitation system: Self excited, SHUNT A.V.R model: AS440 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life

More information

WPS350/S EP Series. Features:

WPS350/S EP Series. Features: Features: Rotate speed governor: Electronic Excitation system: self-excited, SHUNT A.V.R model: R250/R450 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance

More information

WPS60/S EP Series. Features:

WPS60/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited SHUNT A.V.R model: R220/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life

More information

Dongfeng Cummins Techical Operations

Dongfeng Cummins Techical Operations Dongfeng Cummins Techical Operations : Curve and Datasheet:FR20322 Rev01 Date of Issue: 2010/03 450 Dongfeng Cummins Co.,Ltd Generator Performance Data FR20322 @ 1500RPM & 1800RPM : CPL: 3690 Compression

More information

WPS100/S EP Series. Features:

WPS100/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited A.V.R model: R250/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information

*CPL1858 Non Certified **CPL1937 CARB Certified

*CPL1858 Non Certified **CPL1937 CARB Certified CUMMINS ENGINE COMPANY, INC Columbus, Indiana 47202-3005 ENGINE PERFORMANCE CURVE Basic Engine Model: -240G Engine Family: CPL Code: D43 1858 * / 1937** Curve Number: FR-2304 Date: 12Jul94 1 Displacement:

More information

TECHNICAL DATA DEPT. CERTIFIED WITHIN 5% CHIEF ENGINEER

TECHNICAL DATA DEPT. CERTIFIED WITHIN 5% CHIEF ENGINEER CUMMINS ENGINE COMPANY, INC Columbus, Indiana 47202-3005 Engine Performance Curve Basic Engine Model: Curve Number: 6CTA8.3 FR2-9626 Engine Family: CPL Code: Date: D41 1366 18Apr95 13 Displacement: 504.5

More information

WPS250/S EP Series. Features:

WPS250/S EP Series. Features: Features: Rotate speed governor: Electronic Excitation system: self-excited, SHUNT A.V.R model: R250/R450 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance

More information

WPS20/S EP Series. Features:

WPS20/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited SHUNT A.V.R model: R220 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information

WPS150/S EP Series. Features:

WPS150/S EP Series. Features: Features: Rotate speed governor: Mechanical governor Excitation system: self-excited A.V.R model: R250/R438 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed for life maintenance

More information

Dongfeng Cummins Techical Operations

Dongfeng Cummins Techical Operations Dongfeng Cummins Techical Operations ENGINE MODEL: 6BTAA5.9-G12 CURVE & DATASHEET: FR94438 REV 01 20MAY2014 FUEL CONSUMPTION L/H FUEL CONSUMPTION L/H Industrial Engine Performance Data DONGFENG CUMMINS

More information

CUMMINS ENGINE COMPANY, INC. Engine Data Sheet

CUMMINS ENGINE COMPANY, INC. Engine Data Sheet CUMMINS ENGINE COMPANY, INC. Engine Data Sheet Firepump Pg. No. F 43 Engine Model: FIRE PUMP NTTA855-F BIG CAM Data Sheet: FR-1373 Gross Power BHP (kw): 481 (359) @ 2100 Date: 08Mar95 Configuration Number:

More information

Cummins Techical Operations

Cummins Techical Operations Cummins Techical Operations ENGINE MODEL 6BTA5.9-C180 CURVE & DATASHEET FR91536 REV 00 15JUL2006 Basic Engine Model: 6BTA5.9-C180 Engine Performance Curve Engine Family: CPL Code: D40 8541 Displacement:

More information

TPD2250H6.3 TECHNICAL DATA

TPD2250H6.3 TECHNICAL DATA TECHNICAL DATA DIESEL GENERATING SET TONTEK POWER LIMITED GREEN POWER SUPPLIER 50HZ www.tontekpower.com Page: 1/10 Specifications may change without Notice TPD2250H6.3 2250KVA/1800KW POWERED BY CUMMINS

More information

USP&ECummins Series Diesel Generator Set

USP&ECummins Series Diesel Generator Set Powered by Cummins KTA19-G3 565KVA at 60Hz, 480V USP&ECummins Series Diesel Generator Set Genset Model U450-60 Prime Power(60HZ) Standby Power(60HZ) Frequency/Speed Voltage Phases Manufacturer 410KW /

More information

USP&E Cummins Series Diesel Generator Set

USP&E Cummins Series Diesel Generator Set Powered by Cummins KTAA19-G6A 600KVA at 50Hz, 400V USP&E Cummins Series Diesel Generator Set Genset Model U530-50 Prime Power(50HZ) 480KW / 600KVA 528KW / 660KVA Standby Power(50HZ) Frequency/Speed Voltage

More information

DIESEL GENERATOR SET MTU 18V2000 DS1400

DIESEL GENERATOR SET MTU 18V2000 DS1400 DIESEL GENERATOR SET MTU 18V2000 DS1400 Continuous Power: 1000 KVA 380V - 415V/50 Hz/Air Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product Highlights // Benefits - Low

More information

USP&E Cummins Series Diesel Generator Set

USP&E Cummins Series Diesel Generator Set USP&E GLOBAL LLC Powered by Cummins KTA38-G9 1125KVA at 50Hz, 400V USP&E Cummins Series Diesel Generator Set Genset Model U1000 Prime Power(50HZ) 900KW / 1125KVA Standby Power(50HZ) 990KW / 1406KVA Frequency/Speed

More information

Cummins Techical Operations ENGINE MODEL 6CTA8.3-C240 CURVE & DATASHEET FR91499 Rev00 Jun/2006 CUMMINS engine 6CTA8.3-C240

Cummins Techical Operations ENGINE MODEL 6CTA8.3-C240 CURVE & DATASHEET FR91499 Rev00 Jun/2006 CUMMINS engine 6CTA8.3-C240 Cummins Rev Engine Performance Curve Basic Engine Model: Curve Number: 6CTA8.3-C240 Pg. No : Engine Family: CPL Code: Date: 40399 Displacement: 8.3 L Aspiration: Turbocharged & Aftercooled Bore: 114 mm

More information

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life! Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 660KVA Generator Set Specification NO: GKP660KVA2012 c 2012 The Generator King (Pty) Ltd. Ultra Silent,

More information

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life! Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 550KVA Generator Set Specification. Ultra Silent, Extended Life! Page - 1 - of 5 3-Phase, 50Hz@1500RPM

More information

SIVASA Doosan Series. SD250 Technical Data

SIVASA Doosan Series. SD250 Technical Data Powered by Doosan P086TI 250KVA at 60Hz, 220V General feature: Assembled by Doosan diesel engine and Leroy Somer alternator. Three filters as standard, fuel and water separator as optional. Radiator and

More information

USP&E Cummins Series Diesel Generator Set

USP&E Cummins Series Diesel Generator Set Powered by Cummins KTA50-G3 1250KVA at 50Hz, 400V USP&E Cummins Series Diesel Generator Set Genset Model U1100-50 Prime Power(50HZ) 1000KW / 1250KVA Standby Power(50HZ) 1100KW / 1375KVA Frequency/Speed

More information

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V4000 DS2500 DIESEL GENERATOR SET MTU 16V4000 DS2500 380V 11 kv/50 Hz/Standby Power with overload/ta-luft Optimized MTU 16V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary.

More information

DIESEL GENERATOR SET MTU 12V1600 DS660

DIESEL GENERATOR SET MTU 12V1600 DS660 DIESEL GENERATOR SET MTU 12V1600 DS660 400 230 V/659 kva/50 Hz/Standby Power Series 1600 MTU 12V1600 Optional equipment and finishing shown. Standard may vary. Product Highlights // Benefits - Industry-leading

More information

Weifang Ricardo Generator

Weifang Ricardo Generator Weifang Ricardo Generator Genset Model:HR-40GF Standard Features and Characteristics Quality Standards Model HR-40GF The HIGHTECHPOWER generator set compliance with main standards, Rated Power 40kw/50kva

More information

DIESEL GENERATOR SET MTU 16V2000 DS1100

DIESEL GENERATOR SET MTU 16V2000 DS1100 DIESEL GENERATOR SET MTU 16V2000 DS1100 Standby Power: 1100 KVA 380V - 415V/50 Hz/Air Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product Highlights // Benefits - Low

More information

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 16V2000 DS1000 DIESEL GENERATOR SET MTU 16V2000 DS1000 Prime Power: 910 KVA 380V - 415V/50 Hz/Air Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product Highlights // Benefits - Low fuel

More information

CGT Stamford UCI 274 E1

CGT Stamford UCI 274 E1 PERKINS 1106A-70TAG1 CGT Stamford UCI 274 E1 Generator model: UP-P150S-50 50Hz 3-Phase Power Factor Cos Φ = 0.8 MODEL Standby Power(50Hz) Prime Power(50Hz) UP-P150S-50 118kW / 148kVA 108kW / 135kVA Key

More information

DIESEL GENERATOR SET MTU 20V4000 DS3100

DIESEL GENERATOR SET MTU 20V4000 DS3100 DIESEL GENERATOR SET MTU 20V4000 DS3100 380V 11 kv/50 Hz/Standby Power/NEA (ORDE) Optimized MTU 20V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS

More information

DIESEL GENERATOR SET DS03200D5S

DIESEL GENERATOR SET DS03200D5S DIESEL GENERATOR SET DS03200D5S 380V 11 kv/50 Hz/Standby/Fuel Consumption Optimized MTU 20V4000G63L/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS

More information

PGDLS352KW 380/ / / / / / / / /

PGDLS352KW 380/ / / / / / / / / PGDLS352KW 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps HCI 444F 380/220 3 320/400 352/440 607.8 FPA31-3007 208/120 3 320/400

More information

DIESEL GENERATOR SET DP03000D5S

DIESEL GENERATOR SET DP03000D5S DIESEL GENERATOR SET DP03000D5S 380V 11 kv/50 Hz/Prime/TA-Luft Optimized MTU 20V4000G63L/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits

More information

TECHNICAL DATA DEPT. CERTIFIED WITHIN 5% CHIEF ENGINEER

TECHNICAL DATA DEPT. CERTIFIED WITHIN 5% CHIEF ENGINEER CUMMINS ENGINE COMPANY, INC Columbus, Indiana 47202-3005 ENGINE PERFORMANCE CURVE Basic Engine Model: Curve Number: -370E FR-1811 Engine Family: CPL Code: Date: D09 1807 12Aug93 55 Displacement: 855 in.

More information

USP&E Cummins Series Diesel Generator Set

USP&E Cummins Series Diesel Generator Set Powered by Cummins QSK19-G3 650KVA at 50Hz, 400V USP&E Cummins Series Diesel Generator Set Genset Model U570-50 Prime Power(50HZ) 520KW / 650KVA Standby Power(50HZ) 572KW / 715KVA Frequency/Speed 50Hz/1500rpm

More information

PGDLS / / / / / / / / /

PGDLS / / / / / / / / / PGDLS460 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps HCI 544D 380/220 3 416/520 460/575 790.1 FPA35-4002 208/120 3 416/520

More information

DIESEL GENERATOR SET MTU 20V4000 DS2650

DIESEL GENERATOR SET MTU 20V4000 DS2650 DIESEL GENERATOR SET MTU 20V4000 DS2650 380V 11 kv/50 Hz/Prime Power/TA-Luft Optimized MTU 20V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS

More information

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2250 DIESEL GENERATOR SET MTU 16V4000 DS2250 380V 11 kv/50 Hz/Standby Power/Fuel Consumption Optimized MTU 16V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT

More information

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850 PGDLS200 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 380/220 3 184/230 200/250 349.5 FPA27-18010 208/120 3 184/230 200/250

More information

DIESEL GENERATOR SET MTU 12V4000 DS2000

DIESEL GENERATOR SET MTU 12V4000 DS2000 DIESEL GENERATOR SET MTU 12V4000 DS2000 380V 11 kv/50 Hz/Standby Power with overload/nea (ORDE) Optimized MTU 12V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary.

More information

TECHNICAL DATA DEPT. CERTIFIED WITHIN 5% CHIEF ENGINEER

TECHNICAL DATA DEPT. CERTIFIED WITHIN 5% CHIEF ENGINEER CUMMINS ENGINE COMPANY, INC Columbus, Indiana 47202-3005 ENGINE PERFORMANCE CURVE Basic Engine Model: Curve Number: ESP lll FR-1833 Engine Family: CPL Code: Date: D09 1844 12Aug93 139 Displacement: 855

More information

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ CUMMINS Series BC125CS CUMMINS Series Features Photos are for reference only Compact structure & high-strength chassis Easy for operation

More information

2500 Prime 2200 Continuous

2500 Prime 2200 Continuous Generator set data sheet Model: Frequency: Fuel type: kw rating: DQLD 60 Hz Diesel 2750 Standby 2500 Prime 2200 Continuous Exhaust emission data sheet: Sound performance data sheet: Cooling performance

More information

Generator set data sheet Prime. Fuel consumption. Engine Standby rating Prime rating Continuous rating. Fuel flow

Generator set data sheet Prime. Fuel consumption. Engine Standby rating Prime rating Continuous rating. Fuel flow Generator set data sheet Model: Frequency: Fuel type: kw rating: Emissions level: DQLC 60 Hz Diesel 500 Standby 335 Prime 950 Continuous Exhaust emission data sheet: Sound performance data sheet: Cooling

More information

Ratings TAG2A (1500 rpm)...1: TAG2A (1800 rpm)...1: TAG3A (1500 rpm)...1: TAG3A (1800 rpm)...

Ratings TAG2A (1500 rpm)...1: TAG2A (1800 rpm)...1: TAG3A (1500 rpm)...1: TAG3A (1800 rpm)... 527-746 kwm (Gross) @ 1500/1800 rpm 566-839 kwm (Gross) @ 1500/1800 rpm ElectropaK Basic technical data Number of cylinders............................................................6 Cylinder arrangement.......................................

More information

DIESEL GENERATOR SET MTU 20V4000 DS3250

DIESEL GENERATOR SET MTU 20V4000 DS3250 DIESEL GENERATOR SET MTU 20V4000 DS3250 Standby Power: 3250 KWel 13.8kV/60 Hz/Water Charge Air Cooling/Fuel Consumption Optimized Optional equipment and finishing shown. Standard may vary. Product Highlights

More information

DIESEL GENERATOR SET DS01650D5S

DIESEL GENERATOR SET DS01650D5S DIESEL GENERATOR SET DS01650D5S 380V 11 kv/50 Hz/Standby/NEA (ORDE) Optimized MTU 12V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits

More information

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V4000 DS2500 DIESEL GENERATOR SET MTU 16V4000 DS2500 380V 11 kv/50 Hz/Standby Power/Fuel Consumption Optimized MTU 16V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product

More information

DIESEL GENERATOR SET DG00660D5

DIESEL GENERATOR SET DG00660D5 DIESEL GENERATOR SET DG00660D5 400 230 V/600 kva/50 Hz/Prime Series 1600 MTU 12V1600 Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits - Industry-leading average

More information

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 16V2000 DS KVA DIESEL GENERATOR SET MTU 16V2000 DS1100 Data Center Continuous Power: 1000 KVA 380V - 415V/50 Hz/Air Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product Highlights //

More information

2500 Prime 2100 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2

2500 Prime 2100 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 Generator set data sheet Model: DQLF Frequency: 60 Hz Fuel type: Diesel kw rating: 2750 Standby 2500 Prime 2100 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 Exhaust emission data sheet:

More information

PGDLS / / / / / / / / /

PGDLS / / / / / / / / / PGDLS268 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps LSA46.2VL12 HCI 444D 380/220 3 250/313 268/335 474.8 FPA31-2403 HCI 444D

More information

@Perkins. Technical Data Series TAG1A TAG2A TAG3A. Diesel Engine - Electropak. Basic technical data

@Perkins. Technical Data Series TAG1A TAG2A TAG3A. Diesel Engine - Electropak. Basic technical data Technical Data Basic technical data Number of cylinders.................................................... 6 Cylinder arrangement................................... Vertical, In line Cycle....................................4

More information

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps PGCLS400 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps LSA47.2S4 HCI444F 380/220 3 350/438 400/500 664.7 FPA31-3208 208/120 3

More information

TAG2A TAG3A. Series kwm 1500/1800 rpm kwm 1500/1800 rpm ElectropaK. Ratings. Basic technical data

TAG2A TAG3A. Series kwm 1500/1800 rpm kwm 1500/1800 rpm ElectropaK. Ratings. Basic technical data 4006-23TAG2A 527-746 kwm (Gross) @ 1500/10 rpm 4006-23TAG3A 566-839 kwm (Gross) @ 1500/10 rpm ElectropaK 4000 Series Basic technical data Number of cylinders....................................................6

More information

Ultra-low sulphur diesel (15 ppm sulphur)

Ultra-low sulphur diesel (15 ppm sulphur) Generator set data sheet Model: Frequency: Fuel type: kw rating: DQLH 60 Hz Ultra-low sulphur diesel (15 ppm sulphur) 2750 Standby 2500 Prime 2100 Continuous Emissions level: EPA Stationary non-emergency

More information

DIESEL GENERATOR SET MTU 12V4000 DS1750

DIESEL GENERATOR SET MTU 12V4000 DS1750 DIESEL GENERATOR SET MTU 12V4000 DS1750 380V 11 kv/50 Hz/Standby Power/Fuel Consumption Optimized MTU 12V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product

More information

DIESEL GENERATOR SET DP01800D5S

DIESEL GENERATOR SET DP01800D5S DIESEL GENERATOR SET DP01800D5S 380V 11 kv/50 Hz/Prime/Fuel Consumption Optimized MTU 12V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS //

More information

DIESEL GENERATOR SET MTU 20V4000 DS3600

DIESEL GENERATOR SET MTU 20V4000 DS3600 DIESEL GENERATOR SET MTU 20V4000 DS3600 3.3-11 kv/50 Hz/Standby Power/NEA (ORDE) + Tier 2 Optimized MTU 20V4000G94F/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product

More information

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 12V4000 DS1650 DIESEL GENERATOR SET MTU 12V4000 DS1650 380V 11 kv/50 Hz/Grid Stability Power/Fuel Consumption Optimized MTU 12V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary.

More information

DIESEL GENERATOR SET MTU 20V4000 DS4000

DIESEL GENERATOR SET MTU 20V4000 DS4000 DIESEL GENERATOR SET MTU 20V4000 DS4000 11 kv/50 Hz/Prime Power for Stationary Emergency/Fuel Consumption Optimized MTU 20V4000G44LF/Water Charge Air Cooling Optional equipment and finishing shown. Standard

More information