Model ST401G Sampling System

Size: px
Start display at page:

Download "Model ST401G Sampling System"

Transcription

1 User s Manual Model ST401 Sampling System R 6th Edition

2 Blank Page

3 INTRODUCTION <INTRODUCTION> This manual explains the installation, operation and use of the sampling system. Read through this manual before operation for your safety and to obtain the specified performance from the sampling system. Refer to the manuals shown below for the handling of ph converter system and free available chlorine analyzer used with this sampling system. Model Title IM No. PH400 ph Converter IM 12B7C1-02E PH450 ph/orp Converter IM 12B07C05-01E PH8EFP KCl filling type ph Sensor IM 12B7J1-0lE Free Available Chlorine Analyzer IM 12F5A1-0lE (Non-reagent Type) PUS 400 Ultrasonic Oscillator IM 19C1B3-01E PH8HF Flow-Through Type Holder IM 12B07N01-01E i Safety, Protection, and Modification of the Product In order to protect the system controlled by the product and the product itself and ensure safe operation, observe the safety precautions described in this user s manual. We assume no liability for safety if users fail to observe these instructions when operating the product. If this instrument is used in a manner not specified in this user s manual, the protection provided by this instrument may be impaired. If any protection or safety circuit is required for the system controlled by the product or for the product itself, prepare it separately. Be sure to use the spare parts approved by Yokogawa Electric Corporation (hereafter simply referred to as YOKOAWA) when replacing parts or consumables. Modification of the product is strictly prohibited. The following symbols are used in the product and user s manual to indicate that there are precautions for safety: Notes on Handling User s Manuals Please hand over the user s manuals to your end users so that they can keep the user s manuals on hand for convenient reference. Please read the information thoroughly before using the product. The purpose of these user s manuals is not to warrant that the product is well suited to any particular purpose but rather to describe the functional details of the product. No part of the user s manuals may be transferred or reproduced without prior written consent from YOKOAWA. YOKOAWA reserves the right to make improvements in the user s manuals and product at any time, without notice or obligation. If you have any questions, or you find mistakes or omissions in the user s manuals, please contact our sales representative or your local distributor. Media No. 6th Edition :Dec (YK) All Rights Reserved Copyright 1996, Yokogawa Electric Corporation

4 ii <INTRODUCTION> Warning and Disclaimer The product is provided on an as is basis. YOKOAWA shall have neither liability nor responsibility to any person or entity with respect to any direct or indirect loss or damage arising from using the product or any defect of the product that YOKOAWA can not predict in advance. Notes on Hardware Appearance and Accessories Check the following when you receive the product: Appearance Contact our sales representative or your local distributor if the product s coating has come off, it has been damaged. Model and Suffix Codes The name plate on the product contains the model and suffix codes. Compare them with those in the general specification to make sure the product is the correct one. If you have any questions, contact our sales representative or your local distributor. Symbol Marks Throughout this user s manual, you will find several different types of symbols are used to identify different sections of text. This section describes these icons. WARNIN Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. IMPORTANT Indicates that operating the hardware or software in this manner may damage it or lead to system failure. NOTE Draws attention to information essential for understanding the operation and features.

5 After-sales Warranty Do not modify the product. <INTRODUCTION> iii During the warranty period, for repair under warranty consult the local sales representative or service office. Yokogawa will replace or repair any damaged parts. Before consulting for repair under warranty, provide us with the model name and serial number and a description of the problem. Any diagrams or data explaining the problem would also be appreciated. If we replace the product with a new one, we won t provide you with a repair report. Yokogawa warrants the product for the period stated in the pre-purchase quotation Yokogawa shall conduct defined warranty service based on its standard. When the customer site is located outside of the service area, a fee for dispatching the maintenance engineer will be charged to the customer. In the following cases, customer will be charged repair fee regardless of warranty period. Failure of components which are out of scope of warranty stated in instruction manual. Failure caused by usage of software, hardware or auxiliary equipment, which Yokogawa Electric did not supply. Failure due to improper or insufficient maintenance by user. Failure due to modification, misuse or outside-of-specifications operation which Yokogawa does not authorize. Failure due to power supply (voltage, frequency) being outside specifications or abnormal. Failure caused by any usage out of scope of recommended usage. Any damage from fire, earthquake, storms and floods, lightning, disturbances, riots, warfare, radiation and other natural changes. Yokogawa does not warrant conformance with the specific application at the user site. Yokogawa will not bear direct/indirect responsibility for damage due to a specific application. Yokogawa Electric will not bear responsibility when the user configures the product into systems or resells the product. service and supplying repair parts will be covered for five years after the production ends. For repair for this product, please contact the nearest sales office described in this instruction manual.

6 Blank Page

7 <CONTENTS> v Model ST401 Sampling System 6th Edition CONTENTS INTRODUCTION...i After-sales Warranty...iii 1. OVERVIEW System configuration ST401-FC ST401-PH ST401-PF SPECIFICATIONS INSTALLATION, PIPIN, AND WIRIN Unpacking Installation place Installation Piping Wiring OPERATION ST401-FC4-N-A (With free available chlorine analyzer) ST401-PH - -A (With ph converter system) ST401-PF - -A (With ph converter system and free available chlorine analyzer) ST401-FC4-N-A/AZC (With auto zero calibration for free available chlorine analyzer) ST401-PF - -A/AZC (With auto zero calibration for free available chlorine analyzer and ph converter system) MAINTENANCE Confirmation of flow rates of sample Leakage check of each built-in equipment Customer Parts List... CMPL 12A00V02-00E Revision Information...i

8 Blank Page

9 1. OVERVIEW < 1. Overview > 1-1 Model ST401 is a compact sampling system which can be used with the ph converter system and the model non-reagent type free available chlorine analyzer. The measurement can be started after only simple installation because the ST401 is provided with a pressure-reducing valve and ball valve, and shipped with customer ordered devices. 1.1 System configuration There are three types of sampling system. With free available chlorine analyzer, with ph converter (with the ultrasonic cleaner according to order) and with both non-reagent type free available chlorine analyzer and ph converter. The model name and suffix codes are shown in Table 1.1. The outline is shown in item 1.2 to 1.4. Table 1.1 Model and Codes Model Suffix Code Option Code Description ST Sampling system System) -FC4 -PH4 -PH5 -PF4 -PF With free available chlorine analyzer () (note 1) With ph converter (PH400) (note 2) With ph converter (PH450) (note 2) With free available chlorine analyzer () and ph converter (PH400) (note 1) (note 2) (note 3) With free available chlorine analyzer () and ph converter (PH450) (note 1) (note 2) (note 3) Ultrasonic oscillator (for ph meter) -N -U Not supplied Supplied -A... Always -A Option /R /AN /S /ARS /AZC1 /AZC2 /AZC3 /AZC4 /RR /SCT /TT3 Piping connections on the back Without instrument With stainless steel stand (note 4) With arrester (power and signal lines only) (note 5) With auto zero calibration for 100 V AC (note 6) With auto zero calibration for 110 V AC (note 6) With auto zero calibration for 200 V AC (note 6) With auto zero calibration for 220 V AC (note 6) With remote range switching (note 7) With stainless tag plate With 500 ml KCl reserve tank for ph sensor (note 2) Model ST401 refers only to a sampling system and does not include a free available chlorine analyzer and/or a ph meter(sensor,holder,converter and ultrasonic oscillator). (Instrument should be purchased separately.) Note that the ST401 Sampling System accepts the following models of note 1 or note 2 only, and depending on system configuration. Note 1: Non-reagent type free available chlorine analyzer (refer to S 12F5A1-E) When ordering, option code /ST (integration into ST401 sampling system) must be specified. Note 2: 4-wire type ph converter system (refer to S 12B7C1-E, S 12B07C05-01E, S 12B07B02-E,S 12J5C2-E) ph sensor: PH8EFP-03-TN-TT1-N-T*A (when suffix code of -PH4, -PF4 specified.) PH8EFP-03-TN-TT3-N-T*A (when suffix code of -PH4, -PF4 and option code of /TT3 specified.) PH8EFP-03-TN-TT1-N-*A (when suffix code of -PH5, -PF5 specified.) PH8EFP-03-TN-TT3-N-*A (when suffix code of -PH5, -PF5 and option code of /TT3 specified) ph holders: PH8HF-PP-JPT-T-NN-NN*A/MF1 (without cleaning system) PH8HF-S3-JPT-T-NN-NN*A/MF1 (without cleaning system) PH8HF-PP-JPT-T-S3-C1*A/MF1 (with ultrasonic cleaning) PH8HF-S3-JPT-T-S3-C1*A/MF1 (with ultrasonic cleaning) ph converter: PH400- -EA*B (when suffix code of -PH4, -PF4 specified.) PH450-A-E (when suffix code of -PH5, -PF5 specified.) Ultrasonic oscillator: PUS400-NN-NN- -E (which power supply rating should be same as the ph converter.) Note 3: Power supply rating of non-reagent type free available chlorine analyzer should be same as the ph converter. Note 4: Specify if needed, instead of the standard stanchion made of carbon steel. Note 5: Available only when the suffix code -FC4, -PH4 or -PH5 is specified. Note 6: Available when free available chlorine analyzer is specified singly or in combination with ph meter, by suffix code, -FC4, -PF4 or -PF5. Note 7: Available when free available chlorine analyzer is specified singly by suffix code, -FC4. An arrester is supplied automatically with this option.

10 1-2 < 1. Overview > Dimensions, wiring and piping diagram for the ST401 are shown on following pages. For figure numbers to be referred corresponding each models and codes are shown in the Table 1.2 below. Table 1.2 uses following signs. FC: free available chlorine analyzer, ph: ph meter, US: ultrasonic oscillator, ARS: arrester, AZC: auto zero calibration, TT3: 500 ml KCl reserve tank for ph sensor, RR: remote range switching, R: piping connections on the back, Yes: installed, No: not installed, Op: optionally installed Table 1.2 Index of dimensions, wiring and piping diagram Model and codes FC ph US ARS AZC TT3 RR R Dimensions Wiring Piping ST401-FC4-N-A(/ARS) Yes No No Op No No No No Page 4 Page 36 Page 43 ST401-FC4-N-A/R(/ARS) Yes No No Op No No No Yes Page 5 Page 36 Page 43 ST401-FC4-N-A/AZC (/ARS) Yes No No Op Yes No No No Page 6 Page 36 Page 43 ST401-FC4-N-A/R/AZC (/ARS) Yes No No Op Yes No No Yes Page 7 Page 36 Page 43 ST401-FC4-N-A/RR Yes No No Yes No No Yes No Page 8 Page 37 Page 43 ST401-FC4-N-A/R/RR Yes No No Yes No No Yes Yes Page 9 Page 37 Page 43 ST401-FC4-N-A/AZC /RR Yes No No Yes Yes No Yes No Page 10 Page 37 Page 43 ST401-FC4-N-A/R/AZC /RR Yes No No Yes Yes No Yes Yes Page 11 Page 37 Page 43 ST401-PH4- -A(/ARS) No Yes Op Op No No No No Page 12 Page 38 Page 44 ST401-PH4- -A/TT3(/ARS) No Yes Op Op No Yes No No Page 13 Page 38 Page 44 ST401-PH4- -A/R(/ARS) No Yes Op Op No No No Yes Page 14 Page 38 Page 44 ST401-PH4- -A/R/TT3(/ARS) No Yes Op Op No Yes No Yes Page 15 Page 38 Page 44 ST401-PH5- -A(/ARS) No Yes Op Op No No No No Page 16 P. 39, 40 Page 44 ST401-PH5- -A/TT3(/ARS) No Yes Op Op No Yes No No Page 17 P. 39, 40 Page 44 ST401-PH5- -A/R(/ARS) No Yes Op Op No No No Yes Page 18 P. 39, 40 Page 44 ST401-PH5- -A/R/TT3(/ARS) No Yes Op Op No Yes No Yes Page 19 P. 39, 40 Page 44 ST401-PF4- -A Yes Yes Op No No No No No Page 20 Page 41 Page 44 ST401-PF4- -A/TT3 Yes Yes Op No No Yes No No Page 21 Page 41 Page 44 ST401-PF4- -A/R Yes Yes Op No No No No Yes Page 22 Page 41 Page 44 ST401-PF4- -A/R/TT3 Yes Yes Op No No Yes No Yes Page 23 Page 41 Page 44 ST401-PF4- -A/AZC Yes Yes Op No Yes No No No Page 24 Page 41 Page 45 ST401-PF4- -A/TT3/AZC Yes Yes Op No Yes Yes No No Page 25 Page 41 Page 45 ST401-PF4- -A/R/AZC Yes Yes Op No Yes No No Yes Page 26 Page 41 Page 45 ST401-PF4- -A/R/TT3/AZC Yes Yes Op No Yes Yes No Yes Page 27 Page 41 Page 45 ST401-PF5- -A Yes Yes Op No No No No No Page 28 Page 42 Page 44 ST401-PF5- -A/TT3 Yes Yes Op No No Yes No No Page 29 Page 42 Page 44 ST401-PF5- -A/R Yes Yes Op No No No No Yes Page 30 Page 42 Page 44 ST401-PF5- -A/R/TT3 Yes Yes Op No No Yes No Yes Page 31 Page 42 Page 44 ST401-PF5- -A/AZC Yes Yes Op No Yes No No No Page 32 Page 42 Page 45 ST401-PF5- -A/TT3/AZC Yes Yes Op No Yes Yes No No Page 33 Page 42 Page 45 ST401-PF5- -A/R/AZC Yes Yes Op No Yes No No Yes Page 34 Page 42 Page 45 ST401-PF5- -A/R/TT3/AZC Yes Yes Op No Yes Yes No Yes Page 35 Page 42 Page 45

11 1.2 ST401-FC4 < 1. Overview > 1-3 ST401-FC4 is composed with the non-reagent type free available chlorine analyzer (converter and detector) and sampling system. Refer to figure 3.1 to 3.8 for the configuration. NOTE Put ceramic beads in the cell of detector before the measurement. Refer to the manual IM 12F5A1-01E "Model Free Available Chlorine Analyzer (Non-reagent type)" 1.3 ST401-PH ST401-PH u is composed of the PH400 or PH450 ph converter, PH8EFP ph sensor, PH8HF flow-through type ph holder, and sampling system. Moreover, PUS400 ultrasonic cleaner can be built in (optional). Refer to Figure 3.9 to 3.16 for the configuration. NOTE The ph sensor is packed separately. Install and wire as per the manual IM 12B7J1-01E "PH8EFP ph Sensor (KCl filling type)". Refer to Figure 3.36 to 3.43 for the wiring. When option code /TT3 is specified, the 500 ml KCl reserve tank for ph sensor will be installed in the system before factory shipping. 1.4 ST401-PF ST401-PF is composed of ph converter system (converter, sensor, and flow-through type holder), free available chlorine analyzer (converter and detector), and sampling system. Please refer to Figure 3.17 to 3.32 for the configuration. Moreover, the ph converter system can built in ultrasonic cleaner if specified at order time. NOTE The ph sensor is packed separately. Install and wire as per the manual IM 12B7J1-01E "PH8EFP ph Sensor (KCl filling type)". Refer to Figure 3.36 to 3.43 for the wiring also. When option code /TT3 is specified, the 500 ml KCl reserve tank for ph sensor will be installed in the system before factory shipping. Put ceramic beads in the cell of detector before the measurement. Refer to the manual IM 12F5A1-01E "Model Free Available Chlorine Analyzer (Non-reagent type)".

12 Blank Page

13 2. SPECIFICATIONS Measurement: < 2. Specifications > 2-1 chlorine concentration of tap water, ph of or tap water industrial water. Instruments integrated: non-reagent type free available chlorine analyzer, PH400 or PH450 4-wire ph converter system, Refer to respective user s manual. Calibration method: Chlorine analyzer: ph meter: Cleaning system: Manual/auto zero calibration Manual calibration Chlorine analyzer: Not provided ph analyzer: Ultrasonic cleaning Sample (process) conditions: Pressure: 100 to 750 kpa (Under 100 kpa, consult Yokogawa) Flow rate: Chlorine analyzer: 0.1 to 10 l/min ph analyzer: 3 to 10 l/min Temperature: 0 to 50 C Ambient conditions: Temperature: -5 to 50 C (Protection against freeze should be provided when necessary in winter.) Humidity: Storage temperature: 5 to 95% RH, non-condensing (10 to 90 % for ph converter system) -30 to 70 C (-25 to 70 C when using PUS400) Dimensions: Chlorine analyzer integrated: ph analyzer integrated: Both integrated: Materials: 530(W) approx. 1312(H) 550(D) mm 530(W) approx. 1320(H)* 550(D) mm 530(W) approx. 1320(H)* 550(D) mm *) Approx. 1370(H) when option code of /TT3 specified. Piping: Stanchion: Hard PVC, polypropylene resin Carbon steel or stainless steel Finish: Color: Baked polyurethane resin coating Equivalent to Munsell 0.6Y3.1/2.0 I

14 2-2 < 2. Specifications > Installation site: Indoors or in cabinet: not exposed to the weather. Minimal vibration and shock allowed. space required. No corrosive gases present. Moderate humidity. Piping connection: Sample inlet: Drain: Cable inlet: Cable size: Power supply: VP16 VP40 Watertight plastic cable gland equivalent to JIS A15 9 to 12 mm OD 100 V AC ±10%, 50/60 Hz 110 V AC ±10%, 50/60 Hz 200 V AC ±10%, 50/60 Hz 220 V AC ±10%, 50/60 Hz (depending on system configuration) When option code /RR specified, two measurement range set in the can be switched remotely. Remote range switching contact input: Applied voltage when contact input is opened: 5 V DC (Range 1) Applied current when contact input is closed: 20 μa (Range 2) Remote range switching contact output: Contact type: Contact rating: dry contact output 250 V AC, 1A, 125 VA (resistance load) 220 V DC, 1A, 60 W (resistance load) Contact Status at Power OFF Contact Status at Power ON During Nonactivated During Activated Open Open Closed Power consumption: Note : Open: Range 1, Closed: Range 2 Approx. 45 VA (with non-reagent type free available chlorine analyzer, ph converter system, and ultrasonic oscillator) (depending on system configuration) Apparent power of solenoid valve for auto zero calibration When activated: When non-activated: Weight: 22/17 VA (50/60 Hz) 35/27 VA (50/60 Hz) Approx. 45 kg (depending on system configuration)

15 < 3. INSTALLATION, PIPIN AND WIRIN > INSTALLATION, PIPIN, AND WIRIN 3.1 Unpacking The ST401 sampling system is sufficiently packed for shipment to prevent damage during transportation. Unpack carefully near the place of installation. 3.2 Installation place Install the ST401 sampling system at a location as below: (1) Free from rain water such as indoor or in a cubicle (2) Low vibration (3) Low corrosive gas (4) Low humidity (5) Low temperature variation and the temperature is maintained at or as near to room temperature as possible (6) Sufficient maintenance space and easy maintenance access 3.3 Installation Install the sampling system on a well-drained concrete foundation or the equivalent with anchor bolts (M12). Refer to external dimensions (Figure 3.1 to 3.32) for the position of the anchor bolts. Keep sufficient maintenance space around the sampling system.

16 3-2 < 3. INSTALLATION, PIPIN AND WIRIN > 4 - Ø15 holes For anchor bolts Approx. 200 Unit: mm 530 Approx. 200 (Note) NV1 Power line/output signal (Cable O.D. 9 to 12 mm) (100 ) (20) View A Front Approx.500 A chlorine converter chlorine detector Approx Sample inlet VP16 pipe Drain outlet 530 : Pressure reducing valve NV1 : Needle valve : Ball valve (Note) Option code: /ARS (with arrester) Weight : Approx. 35kg Figure 3.1 ST401-FC4-N-A(/ARS) With free available chlorine analyzer, (arrester), (bottom piping)

17 < 3. INSTALLATION, PIPIN AND WIRIN > 3-3 Unit: mm 4 - Ø15 holes For anchor bolts Approx Approx. 200 (Note) Power line/output signal (Cable O.D. 9 to 12 mm) NV (100 ) (20) View A Front Approx.500 A chlorine converter chlorine detector Approx Sample inlet VP16 pipe Drain outlet : Pressure reducing valve NV1 : Needle valve : Ball valve (Note) Option code: /ARS (with arrester) Weight : Approx. 35kg Figure 3.2 ST401-FC4-N-A/R(/ARS) With free available chlorine analyzer, (arrester), (back piping)

18 3-4 < 3. INSTALLATION, PIPIN AND WIRIN > Unit: mm 4 - Ø15 holes For anchor bolts Approx Approx (100 ) (20) View A A chlorine converter chlorine detector (option) (Note) NV1 Activated charcoal filter Sample inlet VP16 pipe Power line/output signal (Cable O.D. 9 to 12 mm) Drain outlet Front Approx.500 SV1 530 SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve : Ball valve (Note) Option code: /ARS (with arrester) Weight : Approx. 40kg Figure 3.3 ST401-FC4-N-A/AZC (/ARS) With free available chlorine analyzer, auto zero calibration, (arrester), (bottom piping)

19 < 3. INSTALLATION, PIPIN AND WIRIN > 3-5 Unit: mm 4 - Ø15 holes For anchor bolts Approx Approx. 200 chlorine converter chlorine detector (option) (Note) Activated charcoal filter Approx.1312 NV1 SV1 Power line/output signal (Cable O.D. 9 to 12 mm) (100 ) (20) View A Front Approx.500 A Sample inlet VP16 pipe Drain outlet SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve : Ball valve (Note) Option code: /ARS (with arrester) Figure 3.4 ST401-FC4-N-A/R/AZC (/ARS/) With free available chlorine analyzer, auto zero calibration, (arrester), (back piping) Weight : Approx. 40kg

20 3-6 < 3. INSTALLATION, PIPIN AND WIRIN > 4 - Ø15 holes For anchor bolts Approx Approx. 200 Unit: mm (100 ) (20) View A Front Approx.500 ph converter PH400 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank ph sensor PH8EFP chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph holder PH8HF Activated charcoal filter Approx.1320 NV1 BV4 SV1 Sample inlet VP16 pipe Drain outlet BV2 250 BV3 Figure SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve to BV4 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) Weight : Approx. 50kg ST401-FC4-N-A/RR With free available chlorine analyzer, remote range switching, (bottom piping)

21 < 3. INSTALLATION, PIPIN AND WIRIN > 3-7 Unit: mm 4 - Ø15 holes For anchor bolts 350 (100 ) Approx Approx (20) Approx NV1 Power line/output signal (Cable O.D. 9 to 12 mm) View A Front Approx.500 A chlorine converter chlorine detector Termimal box for "with arrester" and "remote range setting" Sample inlet VP16 pipe Drain outlet Figure 3.6 : Pressure reducing valve NV1 : Needle valve : Ball valve Weight : Approx. 35kg ST401-FC4-N-A/R/RR With free available chlorine analyzer, remote range switching, (back piping)

22 3-8 < 3. INSTALLATION, PIPIN AND WIRIN > Unit: mm 4 - Ø15 holes For anchor bolts 350 (100 ) Approx Approx (20) View A A chlorine converter chlorine detector Termimal box for "with arrester" and "remote range setting" Activated charcoal filter Approx NV1 SV1 Sample inlet VP16 pipe Power line/output signal (Cable O.D. 9 to 12 mm) Drain outlet Front Approx.500 Figure SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve : Ball valve Weight : Approx. 40kg ST401-FC4-N-A/AZC /RR With free available chlorine analyzer, auto zero calibration, remote range switching, (bottom piping)

23 < 3. INSTALLATION, PIPIN AND WIRIN > 3-9 Unit: mm 4 - Ø15 holes For anchor bolts 350 (100 ) Approx Approx. 200 Activated charcoal filter NV1 SV1 Sample inlet VP16 pipe Power line/output signal (Cable O.D. 9 to 12 mm) (20) View A Front Approx.500 A chlorine converter chlorine detector Termimal box for "with arrester" and "remote range setting" Approx Drain outlet SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve : Ball valve Weight : Approx. 40kg Figure 3.8 ST401-FC4-N-A/R/AZC /RR With free available chlorine analyzer, auto zero calibration, remote range switching, (back piping)

24 3-10 < 3. INSTALLATION, PIPIN AND WIRIN > Unit: mm Approx Approx Ø15 holes For anchor bolts (20) ph ultrasonic oscillator PUS400 (Note 1) (Note 2) Approx.1320 Power line/output signal (Cable O.D. 9 to 12 mm) (100 ) 600 View A Front Approx.500 A ph converter PH400 KCl tank ph sensor PH8EFP ph holder PH8HF Sampe inlet VP16 pipe Drain outlet 530 Figure 3.9 : Pressure reducing valve : Ball valve (Note 1) Suffix code: -U (with ultrasonic oscillator) (Note 2) Suffix code: -U (with ultrasonic oscillator) or Option code: /ARS (with arrester) Weight : Approx. 35kg ST401-PH4- -A(/ARS) With ph converter, (ultrasonic oscillator), (arrester), (bottom piping)

25 < 3. INSTALLATION, PIPIN AND WIRIN > 3-11 Unit: mm Approx Approx Ø15 holes For anchor bolts 350 (100 ) (20) ph ultrasonic oscillator PUS400 (Note 1) (Note 2) Approx.1370 Power line/output signal (Cable O.D. 9 to 12 mm) View A Front Approx.500 A ph converter PH400 KCl tank 500 ml ph sensor PH8EFP ph holder PH8HF Sampe inlet VP16 pipe Drain outlet 530 Figure 3.10 : Pressure reducing valve : Ball valve (Note 1) Suffix code: -U (with ultrasonic oscillator) (Note 2) Suffix code: -U (with ultrasonic oscillator) or Option code: /ARS (with arrester) Weight : Approx. 35kg ST401-PH4- -A/TT3(/ARS) With ph converter, (ultrasonic oscillator), 500 ml KCl tank, (arrester), (bottom piping)

26 3-12 < 3. INSTALLATION, PIPIN AND WIRIN > Unit: mm Approx Approx Ø15 holes For anchor bolts (20) ph ultrasonic oscillator PUS400 (Note 1) ph sensor PH8EFP (Note 2) ph holder PH8HF Approx.1320 Power line/output signal (Cable O.D. 9 to 12 mm) (100 ) 600 View A Front Approx.500 A ph converter PH400 KCl tank Sample inlet VP16 pipe Drain outlet : Pressure reducing valve : Ball valve Figure (Note 1) Suffix code: -U (with ultrasonic oscillator) (Note 2) Suffix code: -U (with ultrasonic oscillator) or Option code: /ARS (with arrester) Weight : Approx. 35kg ST401-PH4- -A/R(/ARS) With ph converter, (ultrasonic oscillator), (arrester), (back piping)

27 < 3. INSTALLATION, PIPIN AND WIRIN > 3-13 Unit: mm Approx Approx Ø15 holes For anchor bolts (20) ph ultrasonic oscillator PUS400 (Note 1) ph sensor PH8EFP (Note 2) ph holder PH8HF Approx.1370 Power line/output signal (Cable O.D. 9 to 12 mm) (100 ) 600 View A Front Approx.500 A ph converter PH400 KCl tank 500 ml Sample inlet VP16 pipe 80 Drain outlet 530 : Pressure reducing valve : Ball valve (Note 1) Suffix code: -U (with ultrasonic oscillator) (Note 2) Suffix code: -U (with ultrasonic oscillator) or Option code: /ARS (with arrester) Weight : Approx. 35kg Figure 3.12 ST401-PH4- -A/R/TT3(/ARS) With ph converter, (ultrasonic oscillator), 500 ml KCl tank, (arrester), (back piping)

28 3-14 < 3. INSTALLATION, PIPIN AND WIRIN > Unit: mm Approx Approx Ø15 holes For anchor bolts (20) ph ultrasonic oscillator PUS400 (Note 1) (Note 2) Approx.1320 Power line/output signal (Cable O.D. 9 to 12 mm) (100 ) 600 View A Front Approx.500 A ph converter PH450 KCl tank ph sensor PH8EFP ph holder PH8HF Sampe inlet VP16 pipe Drain outlet 530 Figure 3.13 : Pressure reducing valve : Ball valve (Note 1) Suffix code: -U (with ultrasonic oscillator) (Note 2) Suffix code: -U (with ultrasonic oscillator) or Option code: /ARS (with arrester) Weight : Approx. 35kg ST401-PH5- -A (/ARS) With ph converter, (ultrasonic oscillator), (arrester), (bottom piping)

29 < 3. INSTALLATION, PIPIN AND WIRIN > 3-15 Unit: mm Approx Approx Ø15 holes For anchor bolts 350 (100 ) (20) ph ultrasonic oscillator PUS400 (Note 1) (Note 2) Approx.1370 Power line/output signal (Cable O.D. 9 to 12 mm) View A Front Approx.500 A ph converter PH450 KCl tank 500 ml ph sensor PH8EFP ph holder PH8HF Sampe inlet VP16 pipe Drain outlet 530 Figure 3.14 : Pressure reducing valve : Ball valve (Note 1) Suffix code: -U (with ultrasonic oscillator) (Note 2) Suffix code: -U (with ultrasonic oscillator) or Option code: /ARS (with arrester) Weight : Approx. 35kg ST401-PH5- -A/TT3(/ARS) With ph converter, (ultrasonic oscillator), 500 ml KCl tank, (arrester), (bottom piping)

30 3-16 < 3. INSTALLATION, PIPIN AND WIRIN > Unit: mm Approx Approx Ø15 holes For anchor bolts (20) ph ultrasonic oscillator PUS400 (Note 1) ph sensor PH8EFP (Note 2) ph holder PH8HF Approx.1320 Power line/output signal (Cable O.D. 9 to 12 mm) (100 ) 600 View A Front Approx.500 A ph converter PH450 KCl tank Sample inlet VP16 pipe Drain outlet : Pressure reducing valve : Ball valve? Figure (Note 1) Suffix code: -U (with ultrasonic oscillator) (Note 2) Suffix code: -U (with ultrasonic oscillator) or Option code: /ARS (with arrester) Weight : Approx. 35kg ST401-PH5- -A/R (/ARS) With ph converter, (ultrasonic oscillator), (arrester), (back piping)

31 < 3. INSTALLATION, PIPIN AND WIRIN > 3-17 Unit: mm Approx Approx Ø15 holes For anchor bolts (20) ph ultrasonic oscillator PUS400 (Note 1) ph sensor PH8EFP (Note 2) ph holder PH8HF Power line/output signal (Cable O.D. 9 to 12 mm) (100 ) 600 View A Front Approx.500 A ph converter PH450 KCl tank 500 ml Approx.1370 Sample inlet VP16 pipe Drain outlet : Pressure reducing valve : Ball valve (Note 1) Suffix code: -U (with ultrasonic oscillator) (Note 2) Suffix code: -U (with ultrasonic oscillator) or Option code: /ARS (with arrester) Weight : Approx. 35kg Figure 3.16 ST401-PH5- -A/R/TT3(/ARS) With ph converter, (ultrasonic oscillator), 500 ml KCl tank, (arrester), (back piping)

32 3-18 < 3. INSTALLATION, PIPIN AND WIRIN > 4 - Ø15 holes For anchor bolts Approx Approx. 200 Unit: mm (20) ph converter PH400 chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) NV1 BV (100 ) 600 View A Front Approx.500 A ph sensor PH8EFP ph holder PH8HF Approx.1320 Sample inlet VP16 pipe Drain outlet Figure : Pressure reducing valve NV1 : Needle valve, BV2 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) ST401-PF4- -A With free available chlorine analyzer, ph converter, (ultrasonic oscillator), (bottom piping) Weight : Approx. 45kg

33 < 3. INSTALLATION, PIPIN AND WIRIN > 3-19 Unit: mm Approx Approx Ø15 holes For anchor bolts 350 (100 ) (20) ph converter PH400 chlorine converter ph ultrasonic oscillator PUS400 (Note) chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) NV1 BV View A Front Approx.500 A KCl tank 500ml ph sensor PH8EFP ph holder PH8HF Approx.1370 Sample inlet VP16 pipe Drain outlet Figure : Pressure reducing valve NV1 : Needle valve, BV2 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) ST401-PF4- -A/TT3 With free available chlorine analyzer, ph converter, (ultrasonic oscillator), 500 ml KCl tank, (bottom piping) Weight : Approx. 45kg

34 3-20 < 3. INSTALLATION, PIPIN AND WIRIN > 4 - Ø15 holes For anchor bolts Approx Approx. 200 Unit: mm (100 ) (20) View A Front Approx.500 ph converter PH400 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph sensor PH8EFP ph holder PH8HF Approx.1320 NV1 BV2 Sample inlet VP16 pipe Drain outlet Figure 3.19 : Pressure reducing valve NV1 : Needle valve, BV2 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) ST401-PF4- -A/R With free available chlorine analyzer, ph converter, (ultrasonic oscillator), (back piping) Weight : Approx. 45kg

35 < 3. INSTALLATION, PIPIN AND WIRIN > 3-21 Unit: mm Approx Approx Ø15 holes For anchor bolts 350 (100 ) (20) View A Front Approx.500 ph converter PH400 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank 500ml chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph sensor PH8EFP ph holder PH8HF Approx.1370 NV1 BV2 Sample inlet VP16 pipe Drain outlet Figure 3.20 : Pressure reducing valve NV1 : Needle valve, BV2 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) Weight : Approx. 45kg ST401-PF4- -A/R/TT3 With free available chlorine analyzer, ph converter, (ultrasonic oscillator), 500 ml KCl tank, (back piping)

36 3-22 < 3. INSTALLATION, PIPIN AND WIRIN > 4 - Ø15 holes For anchor bolts Approx Approx. 200 Unit: mm (100 ) (20) View A Front Approx.500 ph converter PH400 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank ph sensor PH8EFP chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph holder PH8HF Activated charcoal filter Approx.1320 NV1 BV4 SV1 Sample inlet VP16 pipe Drain outlet BV2 250 BV3 Figure SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve to BV4 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) ST401-PF4- -A/AZC With free available chlorine analyzer, auto zero calibration, ph converter, (ultrasonic oscillator), (bottom piping) Weight : Approx. 50kg

37 < 3. INSTALLATION, PIPIN AND WIRIN > 3-23 Unit: mm Approx Approx Ø15 holes For anchor bolts (100 ) (20) View A Front Approx.500 ph converter PH400 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank 500ml ph sensor PH8EFP chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph holder PH8HF Activated charcoal filter Approx.1370 NV1 BV4 SV1 Sample inlet VP16 pipe Drain outlet BV2 250 BV3 Figure SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve to BV4 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) Weight : Approx. 50kg ST401-PF4- -A/TT3/AZC With free available chlorine analyzer, auto zero calibration, ph converter, (ultrasonic oscillator), 500 ml KCl tank, (bottom piping)

38 3-24 < 3. INSTALLATION, PIPIN AND WIRIN > Unit: mm 4 - Ø15 holes For anchor bolts Approx Approx (100 ) (20) View A Front Approx.500 ph converter PH400 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank ph sensor PH8EFP chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph holder PH8HF Activated charcoal filter Approx.1320 NV1 BV4 SV1 Sample inlet VP16 pipe Drain outlet BV2 BV Figure 3.23 SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve to BV4 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) Weight : Approx. 50kg ST401-PF4- -A/R/AZC With free available chlorine analyzer, auto zero calibration, ph converter, (ultrasonic oscillator), (back piping)

39 < 3. INSTALLATION, PIPIN AND WIRIN > 3-25 Unit: mm Approx Approx Ø15 holes For anchor bolts 350 (100 ) (20) View A Front Approx.500 ph converter PH400 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank 500ml ph sensor PH8EFP chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph holder PH8HF Activated charcoal filter Approx.1370 NV1 BV4 SV1 Sample inlet VP16 pipe Drain outlet BV2 BV SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve to BV4 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) Weight : Approx. 50kg Figure 3.24 ST401-PF4- -A/R/TT3/AZC With free available chlorine analyzer, auto zero calibration, ph converter, (ultrasonic oscillator), 500 ml KCl tank, (back piping)

40 3-26 < 3. INSTALLATION, PIPIN AND WIRIN > 4 - Ø15 holes For anchor bolts Approx Approx. 200 Unit: mm (20) ph converter PH450 chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) NV1 BV (100 ) 600 View A Front Approx.500 A ph sensor PH8EFP ph holder PH8HF Approx.1320 Sample inlet VP16 pipe Drain outlet Figure : Pressure reducing valve NV1 : Needle valve, BV2 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) ST401-PF5- -A With free available chlorine analyzer, ph converter, (ultrasonic oscillator), (bottom piping) Weight : Approx. 45kg

41 < 3. INSTALLATION, PIPIN AND WIRIN > 3-27 Unit: mm Approx Approx Ø15 holes For anchor bolts 350 (100 ) (20) ph converter PH450 chlorine converter ph ultrasonic oscillator PUS400 (Note) chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) NV1 BV View A Front Approx.500 A KCl tank 500ml ph sensor PH8EFP ph holder PH8HF Approx.1370 Sample inlet VP16 pipe Drain outlet Figure : Pressure reducing valve NV1 : Needle valve, BV2 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) ST401-PF5- -A/TT3 With free available chlorine analyzer, ph converter, (ultrasonic oscillator), 500 ml KCl tank, (bottom piping) Weight : Approx. 45kg

42 3-28 < 3. INSTALLATION, PIPIN AND WIRIN > 4 - Ø15 holes For anchor bolts Approx Approx. 200 Unit: mm (100 ) (20) View A Front Approx.500 ph converter PH450 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph sensor PH8EFP ph holder PH8HF Approx.1320 NV1 BV2 Sample inlet VP16 pipe Drain outlet Figure 3.27 : Pressure reducing valve NV1 : Needle valve, BV2 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) ST401-PF5- -A/R With free available chlorine analyzer, ph converter, (ultrasonic oscillator), (back piping) Weight : Approx. 45kg

43 < 3. INSTALLATION, PIPIN AND WIRIN > 3-29 Unit: mm Approx Approx Ø15 holes For anchor bolts 350 (100 ) (20) View A Front Approx.500 ph converter PH450 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank 500ml chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph sensor PH8EFP ph holder PH8HF Approx.1370 NV1 BV2 Sample inlet VP16 pipe Drain outlet Figure 3.28 : Pressure reducing valve NV1 : Needle valve, BV2 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) ST401-PF5- -A/R/TT3 With free available chlorine analyzer, ph converter, (ultrasonic oscillator), 500 ml KCl tank, (back piping) Weight : Approx. 45kg

44 3-30 < 3. INSTALLATION, PIPIN AND WIRIN > 4 - Ø15 holes For anchor bolts Approx Approx. 200 Unit: mm (100 ) (20) View A Front Approx.500 ph converter PH450 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank ph sensor PH8EFP chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph holder PH8HF Activated charcoal filter Approx.1320 NV1 BV4 SV1 Sample inlet VP16 pipe Drain outlet BV2 250 BV3 530 SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve to BV4 : Ball valve Figure (Note) Suffix code: -U (with ultrasonic oscillator) Weight : Approx. 50kg ST401-PF5- -A/AZC With free available chlorine analyzer, ph converter, (ultrasonic oscillator), auto zero calibration, (bottom piping)

45 < 3. INSTALLATION, PIPIN AND WIRIN > 3-31 Unit: mm Approx Approx Ø15 holes For anchor bolts (100 ) (20) View A Front Approx.500 ph converter PH400 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank 500ml ph sensor PH8EFP chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph holder PH8HF Activated charcoal filter Approx.1370 NV1 BV4 SV1 Sample inlet VP16 pipe Drain outlet BV2 250 BV3 Figure SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve to BV4 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) Weight : Approx. 50kg ST401-PF5- -A/TT3/AZC With free available chlorine analyzer, auto zero calibration, ph converter, (ultrasonic oscillator), 500 ml KCl tank, (bottom piping)

46 3-32 < 3. INSTALLATION, PIPIN AND WIRIN > 4 - Ø15 holes For anchor bolts Approx Approx. 200 Unit: mm (100 ) (20) View A Front Approx.500 ph converter PH450 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank ph sensor PH8EFP chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph holder PH8HF Activated charcoal filter Approx.1320 NV1 BV4 SV1 Sample inlet VP16 pipe Drain outlet BV2 BV SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve to BV4 : Ball valve Figure 3.31 (Note) Suffix code: -U (with ultrasonic oscillator) Weight : Approx. 50kg ST401-PF5- -A/R/AZC With free available chlorine analyzer, (auto zero calibration), ph converter, (ultrasonic oscillator), (back piping)

47 < 3. INSTALLATION, PIPIN AND WIRIN > 3-33 Unit: mm Approx Approx Ø15 holes For anchor bolts 350 (100 ) (20) View A Front Approx.500 ph converter PH450 A chlorine converter ph ultrasonic oscillator PUS400 (Note) KCl tank 500ml ph sensor PH8EFP chlorine detector Power line/output signal (Cable O.D. 9 to 12 mm) ph holder PH8HF Activated charcoal filter Approx.1370 NV1 BV4 SV1 Sample inlet VP16 pipe Drain outlet BV2 BV Figure 3.32 SV1 : 3-way solenoid valve : Pressure reducing valve NV1 : Needle valve to BV4 : Ball valve (Note) Suffix code: -U (with ultrasonic oscillator) Weight : Approx. 50kg ST401-PF5- -A/R/TT3/AZC With free available chlorine analyzer, auto zero calibration, ph converter, (ultrasonic oscillator), 500 ml KCl tank, (back piping)

48 Piping < 3. INSTALLATION, PIPIN AND WIRIN > Pressure range of measuring water is from 100 to 750 kpa (1 to 7.5 kg/cm 2 ) and the flow rate is from 0.1 to 10 l/min. Measuring water pipe should be hard PVC and VP16 (22 mm O.D.). Drain pipe should be hard PVC and VP40 (48 mm O.D.). Use proper sized or other fittings which suit those pipe sizes. Refer to external dimension (Figure 3.1 to 3.32) for the piping. Drain pipe should be inclined, to prevent build up of deposits and blockage. Horizontal piping should be as short as possible and should have a slope. NOTE When the system is used for measurement in heavily contaminated water other than tap water and industrial water, the filter of the pressure reducing valve may be clogged early. In that case take measures to avoid contamination, e.g., changing the sampling point. 3.5 Wiring WARNIN Do not supply the electric power until the wiring is completed. Electric shock may cause serious injury or death (1) Power supply The converter unit should be directly wired if only the ph converter system or the free available chlorine analyzer is installed in the sampling system. Refer to Figure 3.33 to 3.41 for the wiring of each equipment. A terminal box is installed when there are two or more converters including ultrasonic cleaner, or when arrestor option is specified. The power supply of ph converter, ultrasonic cleaner, and free available chlorine converter is wired from this terminal box. Connect the power supply wiring to corresponding terminals of the terminal box, refer to Figure 3.33 to Figure The terminal screw is M4. Use suitable terminal. (2) Analog output and contact output Refer to the manuals of ph converter and free available chlorine converter for their analog output and contact output wiring. Connect each wiring to corresponding terminals of the terminal box, refer to Figure 3.33 to Figure 3.43.

49 < 3. INSTALLATION, PIPIN AND WIRIN > 3-35 chlorine converter () chlorine detector () Customer wiring Power *1 round MAINT FAIL Output signal *2 *2 *3 M1 M2 F1 F2 + - POWER OUTPUT T1 T2 RE ME C1 C2 W2 W1 *1 T1 T2 RE ME C1 C2 Solenoid valve (SV1) Option for "/AZC " (with auto zero calibration) *1: Be sure to ground the case ground terminal, or if this is not possible then connect to of power wiring. Avoid two-point ground. (Case is connected to signal ground inside converter). *2: Use cable with 9 to 12 mm OD. *3: Use two-core shielded cable with 9 to 12 mm OD. To avoid two-point ground, connect shield to ground at one end only. Figure 3.33 AR2x2 2 1 CB1 AR1 AR1,2 : arresters CB1: Circuit breaker Figure 3.34 Wiring Diagram of ST401-FC4-N-A(/AZC ) - + S - + round Power Analog output MAINT FAIL chlorine converter () M1 M2 F1 F2 + - POWER OUTPUT T1 T2 RE ME C1 C2 W2 W1 Solenoid valve (SV1) chlorine detector () T1 T2 RE ME C1 C2 Dedicated cable Output Option for "/AZC " (with auto zero calibration) (Note) * Dotted wiring is external wiring and should be prepared by customer. * Use two-core shielded cable with 9 to 12 mm OD for output wiring. Avoid two-point ground. * round the terminal of power wiring. Wiring Diagram of ST401-FC4-N-A/ARS(/AZC )

50 3-36 < 3. INSTALLATION, PIPIN AND WIRIN > chlorine converter chlorine detector R 4 - COM - V V + L SP1 N AR2x O2 O1 R2 R1 R2 R1 CB1 2 1 AR1 S R2 R1 W2 W1 OUTPUT POWER T1 T2 RE ME C1 C2 M1 M2 F1 F2 MAINT FAIL (Customer wiring) T1 T2 RE ME C1 C2 Dedicated cable Solenoid valve (SV1) Option for "/AZC " (with auto zero calibration) AR1,2 : arresters CB1: Circuit breaker Power round Remote range switching input Range switching output Analog output (Note) * Dotted wiring is external wiring and should be prepared by customer. * Use two-core shielded cable with 9 to 12 mm OD for output wiring. * Remote range switching Voltage when contact input opened: 5 V DC Current when contact input closed: 20μA Avoid two-point ground. * round the terminal of power wiring. External wiring (Remote range switching input) External wiring (Remote range switching output) External wiring (Analog output) External wiring should be prepared by customer. External wiring (Power) (Power) (Range swiching input) (Output signal) Figure 3.35 Wiring Diagram of ST401-FC4-N-A/RR(/AZC )

51 < 3. INSTALLATION, PIPIN AND WIRIN > 3-37 Customer wiring *2 ph converter (PH400) S1 - S3 FAIL R1 R2 S E T2 T1 SE RE Sensor cable (Customer wiring) ph sensor (PH8EFP) (Customer installation) Flow-Through type holder (PH8HF) *3 - + *1 Power Customer wiring round*1 *1: Be sure to ground the case ground terminal, or if this is not possible then connect to of power wiring. Avoid two-point ground. (Case is connected to signal ground inside converter). *2: Use cable with 9 to 12 mm OD. *3: Use two-core shielded cable with 9 to 12 mm OD. Avoid two-point ground. Figure 3.36 Wiring Diagram of ST401-PH4-N-A (PH400) Customer wiring ph converter (PH400) S1 - S3 FAIL R1 R2 S E T2 T1 SE RE Sensor cable (Customer wiring) ph sensor (PH8EFP) (Customer installation) ph holder (PH8HF) RN - + Ultrasonic oscillator cable YEL YEL YEL YEL RN YEL YEL Ultrasonic oscillator (PUS400) U1 U2 S CB1 RN YEL YEL (Note) * Dotted wiring is external wiring and should be prepared by customer. * Use two-core shielded cable with 9 to 12 mm OD for output wiring. CB1: Circuit breaker Avoid two-point ground. * round the terminal of power wiring. Power, round Figure 3.37 Wiring Diagram of ST401-PH4-U-A (PH400)

52 3-38 < 3. INSTALLATION, PIPIN AND WIRIN > ph converter (PH400) S1 - S3 FAIL R1 R2 S E T2 T1 SE RE Sensor cable (Customer wiring) ph sensor (PH8EFP) (Customer installation) ph holder (PH8HF) AR2x2 - + S Ultrasonic oscillator cable Ultrasonic oscillator (Suffic code: -U) (PUS400) 2 1 CB1 AR1 U1 U2 S AR1,2: arresters CB1: Circuit breaker round (Note) * Dotted wiring is external wiring and should be prepared by customer. * Use two-core shielded cable with 9 to 12 mm OD for output wiring. Avoid two-point ground. * round the terminal of power wiring. Figure 3.38 Power Output Wiring Diagram of ST401-PH4- -A/ARS (PH400) ph converter (PH450) Sensor cable (Customer wiring) ph sensor (PH8EFP) (Customer installation) (S)16 (E)15 (SE)14 IMPLOW Customer Jumper Flow-Through type holder wiring (RE)13 (Note) (PH8HF) *2 (T2)12 *3 63 (T1)11 62(-) ma1 61(+) 1L 2N *1 Power Customer wiring round*1 (Note) For the jumper wiring, refer to user s manual of PH450. *1: Be sure to ground the case ground terminal, or if this is not possible then connect to of power wiring. Avoid two-point ground. (Case is connected to signal ground inside converter). *2: Use cable with 9 to 12 mm OD. *3: Use two-core shielded cable with 9 to 12 mm OD. Avoid two-point ground. Figure 3.39 S1 to S3 S4 Wiring Diagram of ST401-PH5-N-A (PH450)

53 < 3. INSTALLATION, PIPIN AND WIRIN > 3-39 YEL YEL Customer wiring RN YEL YEL RN YEL YEL ph converter (PH450) (S)16 (E)15 (SE)14 IMPLOW (RE)13 (T2)12 63 (T1)11 62(-) ma1 61(+) 1L 2N S1 to S3 S4 Jumper Sensor cable (Note 1) (Customer wiring) ph sensor (PH8EFP) (Customer installation) ph holder (PH8HF) Ultrasonic oscillator cable Ultrasonic oscillator (PUS400) U1 U2 S CB1 RN YEL YEL (Note 1) For the jumper wiring, refer to user s manual of PH450. (Note 2) * Dotted wiring is external wiring and should be prepared by customer. * Use two-core shielded cable with 9 to 12 mm OD for output wiring. CB1: Circuit breaker Avoid two-point ground. * round the terminal of power wiring. Power, round Figure 3.40 Wiring Diagram of ST401-PH5-U-A (PH450) AR2x2 2 1 CB1 AR1 - + S - + AR1,2: arresters CB1: Circuit breaker round ph converter (PH450) (S)16 (E)15 (SE)14 IMPLOW (RE)13 (T2)12 63 (T1)11 62(-) ma1 61(+) 1L 2N S1 to S3 S4 Jumper (Note 1) Sensor cable (Customer wiring) ph sensor (PH8EFP) (Customer installation) ph holder (PH8HF) Ultrasonic oscillator cable Ultrasonic oscillator (Suffic code: -U) (PUS400) (Note 1) For the jumper wiring, refer to user s manual of PH450. (Note 2) * Dotted wiring is external wiring and should be prepared by customer. * Use two-core shielded cable with 9 to 12 mm OD for output wiring. Avoid two-point ground. * round the terminal of power wiring. U1 U2 S Figure 3.41 Power Output Wiring Diagram of ST401-PH5- -A/ARS (PH450)

Model PH8HG Drop-in Guide Pipe

Model PH8HG Drop-in Guide Pipe User s Manual Model PH8HG Drop-in Guide Pipe R 3rd Edition Blank Page INTRODUCTION This manual covers the PH8HG drop-in guide pipe. Other related items are described in the following manuals:

More information

General Specifications

General Specifications eneral Specifications Model TB Surface Scattering Light Meter S 12E04A02-01E eneral There have been increasing demands for both industrial use and portable water of good quality because of rapid industrial

More information

Model TB400G Surface Scattering Light Turbidity Meter [Style: S3]

Model TB400G Surface Scattering Light Turbidity Meter [Style: S3] User s Manual Model TB400G Surface Scattering Light Turbidity Meter [Style: S3] IM 12E04A02-02E IM 12E04A02-02E 7th Edition INTRODUCTION i Structure of this Manual This manual describes the specifications,

More information

Model FU20 ph/orp Sensor

Model FU20 ph/orp Sensor User s Manual Model FU20 ph/orp Sensor 4th Edition INTRODUCTION This user s manual provides information for the installation and use of the FU20 ph/orp sensor. The FU20 is the choice for

More information

Model FC400G Free Available Chlorine Analyzer (Non-Reagent Type)

Model FC400G Free Available Chlorine Analyzer (Non-Reagent Type) User s Manual Model FC400G Free Available Chlorine Analyzer (Non-Reagent Type) R 4th Edition Blank Page INTRODUCTION i Safety, Protection, and Modification of the Product In order to protect

More information

Model PH8EHP ph Sensor for High Purity Water

Model PH8EHP ph Sensor for High Purity Water User s Manual Model PH8EHP ph Sensor for High Purity Water R 7th Edition Blank Page INTRODUCTION This manual covers the PH8EHP ph Sensor for High Purity Water. Other related items are described in the

More information

User s Manual Model PH10RP KCl Replenish-free ph Sensor

User s Manual Model PH10RP KCl Replenish-free ph Sensor User s Manual Model PH10RP KCl Replenish-free ph Sensor 1st Edition Safety Precautions Introduction This instruction manual covers the PH10RP KCl Replenish-free ph sensor for the PH100. Other related EXA100

More information

Model OR8ERG KCl Refillable type ORP Sensor

Model OR8ERG KCl Refillable type ORP Sensor User s Manual Model OR8ERG KCl Refillable type ORP Sensor R 4th Edition Blank Page INTRODUCTION This manual covers the OR8ERG KCl Refillable type ORP Sensor. Other related items are described in the following

More information

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation User s Manual 701934 Power Supply Yokogawa Electric Corporation 2nd Edition Foreword Revisions Thank you for purchasing the 701934 Power Supply. This user's manual contains useful information about the

More information

General Specifications

General Specifications General Specifications Chemical Cleaning ph Measuring System GS B7A-E General Process ph measuring systems have played an important role in many fields including the chemical, food, metal, and paper pulp

More information

Model PH8HF, PH8HFF Flow-Through Type Holder

Model PH8HF, PH8HFF Flow-Through Type Holder User s Manual Model PH8HF, PH8HFF Flow-Through Type Holder 5th Edition INTRODUCTION This manual covers the PH8HF, PH8HFF Flow-Through Type Holder. Other related items are described in the

More information

Model OR8ERG KCl Refillable type ORP Sensor

Model OR8ERG KCl Refillable type ORP Sensor User s Manual Model OR8ERG KCl Refillable type ORP Sensor R 5th Edition INTRODUCTION This manual covers the OR8ERG KCl Refillable type ORP Sensor. Other related items are described in the

More information

General Specifications

General Specifications General Specifications DO0G Sensor for Dissolved Oxygen Analyzer GS 2J05D0-0E GENERA The DO0G sensor for dissolved oxygen is designed for use in water treatment plants such as sewage treatment works, effluent

More information

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation User s Manual 700938 Power Supply Yokogawa Electric Corporation 3rd Edition Introduction Revisions Thank you for purchasing the 700938 Power Supply. This Instruction Manual contains useful information

More information

User s Manual Power Supply IM E. 5th Edition

User s Manual Power Supply IM E. 5th Edition User s Manual 700938 Power Supply 5th Edition Thank you for purchasing the 700938 Power Supply. This user s manual contains useful information about the instrument s functions and operating procedures

More information

Model RC400G Residual Chlorine Analyzer

Model RC400G Residual Chlorine Analyzer User s Manual Model RC400G Residual Chlorine Analyzer [Style: S3] 8th Edition Introduction The RC400G Residual Chlorine Analyzer is a process analyzer for continuous measurement of free chlorine concentration

More information

General Specifications

General Specifications General Specifications DO30G Sensor for Dissolved Oxygen Analyzer GS 2J05D03-0E GENERA The DO30G sensor for dissolved oxygen is designed for use in water treatment plants such as sewage treatment works,

More information

Model PH8ERP KCl Refillable type ph Sensor

Model PH8ERP KCl Refillable type ph Sensor User s Manual Model PH8ERP KCl Refillable type ph Sensor R 7th Edition Blank Page INTRODUCTION This manual covers the PH8ERP KCl Refillable type ph Sensor. Other related items are described in the following

More information

General Specifications

General Specifications General Specifications Sensor Holders GS 12J5C2-E GENERAL Various types of analyzers are used to control quality and wastewater in a wide variety of production processes. Holders are used to set up analyzers

More information

Model PH8HH ph Holder for High Purity Water

Model PH8HH ph Holder for High Purity Water User s Manual Model PH8HH ph Holder for High Purity Water R 3rd Edition Toc-1 Model PH8HH ph Holder for High Purity Water 3rd Edition CONTENTS 1. Overview... 1-1 1.1 Standard Specifications...

More information

General Specifications

General Specifications General Specifications Sensor Holders GS 12J05C02-00E GENERAL Various types of analyzers are used to control quality and wastewater in a wide variety of production processes. Holders are used to set up

More information

Model FC500G Free Available Chlorine Analyzer (Non-Reagent Type)

Model FC500G Free Available Chlorine Analyzer (Non-Reagent Type) User s Manual Model FC500G Free Available Chlorine Analyzer (Non-Reagent Type) TM 5th Edition Introduction This user s manual describes the specifications, installation, operation, maintenance, and troubleshooting

More information

Read and understand this manual for safely usage.

Read and understand this manual for safely usage. TS02-0183 INSTRUCTION MANUAL FOR GUARD TYPE LEVEL SENSOR MODEL:FC Read and understand this manual for safely usage. This manual describes the product of standard specification. Read the other manual for

More information

HF2 Gauge Installation Guide Scantech

HF2 Gauge Installation Guide Scantech HF2 Gauge Installation Guide 2013-09-13 Scantech 2 Contents Property Note... 5 Conventions...5 Safety Precautions...5 Contact... 7 Placing the Gauge in Its Allocated Space... 9 Positioning the Gauge...9

More information

Model GD-K77D4X-XX Supplement to the GD-K77D Operator s Manual

Model GD-K77D4X-XX Supplement to the GD-K77D Operator s Manual Model GD-K77D4X-XX Supplement to the GD-K77D Operator s Manual Part Number: 71-0217RK Revision: 0 Released: 3/1/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

General Specifications

General Specifications General Specifications Model DT450G Dust Monitor GENERAL Powder is used in many industries including ceramics,cement, chemicals, pharmaceutical and food. In their processes, powder is collected in order

More information

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to PRM-4 Phase Sequence and Motor Rotation Tester Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com PRM-4 Phase Sequence and Motor Rotation Tester English Users Manual

More information

Read and understand this manual for safely usage.

Read and understand this manual for safely usage. TS02-0180 INSTRUCTION MANUAL FOR AIR BUBBLER SYSTEM LEVEL MEASUREMENT MODEL:LA100 MODEL:LA110 MODEL:LA1000 Read and understand this manual for safely usage. This manual describes the product of standard

More information

General Specifications

General Specifications General Specifications Sensor Holders GS 12J05C02-00E GENERAL Various types of analyzers are used to control quality and wastewater in a wide variety of production processes. Holders are used to set up

More information

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition User's Manual MV100 Rechargeable Battery Model Yokogawa Electric Corporation 1st Edition Thank you for purchasing the MV100 Rechargeable Battery Model. This user s manual describes the rechargeable batteries.

More information

VM-5 SERIES MONITOR MODEL VM-5Z3 POWER SUPPLY UNIT INSTRUCTION MANUAL

VM-5 SERIES MONITOR MODEL VM-5Z3 POWER SUPPLY UNIT INSTRUCTION MANUAL MANUAL NO. 20009E1.3 Published in Nov.2000 Revised in Mar. 2010 VM-5 SERIES MONITOR MODEL VM-5Z3 POWER SUPPLY UNIT INSTRUCTION MANUAL SAFETY CONVENTIONS VM-5Z3 For safe operation... Thank you for using

More information

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER THT-500-A/R No.THT51E1 2017.12 Thank you for purchasing our THT-500-A/R, Temperature and Humidity Transmitter (mounted within control panel). This

More information

General Specifications

General Specifications General Specifications Models RM and RH Resistance Temperature Sensor GS 06B03B01-00E GENERAL Model RM and RH Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50 ) in

More information

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to RS-3 PRO RS-1007 PRO CAT IV Analog Clamp meter Series Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com RS-3 PRO RS-1007 PRO CAT IV Analog Clampmeter Series English

More information

Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual

Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual Part Number: 71-0192RK Revision: A Released: 1/27/17 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

Galaxy VM. Battery Breaker Box Installation 09/

Galaxy VM. Battery Breaker Box Installation 09/ Galaxy VM Battery Breaker Box Installation 09/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred

More information

Lumitester PD-30. Instruction Manual. Table of Contents

Lumitester PD-30. Instruction Manual. Table of Contents Table of Contents Lumitester PD-30 Instruction Manual Thank you very much for purchasing the Lumitester PD-30. All of this Instruction Manual must be read before operation of this product for safe and

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

General Specifications

General Specifications General Specifications PH4/OR4 Sensor Series ph and ORP Sensors GS B10B00-01EN GENERAL Yokogawa s line of ph sensors has been strengthened by the inclusion of the polymer electrolyte ph sensor PH4P/PH4PT,

More information

Differential Pressure Transmitter

Differential Pressure Transmitter Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused

More information

General Specifications

General Specifications General Specifications PH4/OR4 Sensor Series ph and ORP Sensors GS B10B00-01EN GENERAL Yokogawa s line of ph sensors has been strengthened by the inclusion of the polymer electrolyte ph sensor /T, HF-resistant

More information

General Specifications

General Specifications General Specifications Model RS and RN Resistance Temperature Sensor GS 06B04D01-00E GENERAL Model RS and RN Resistance Temperature Sensors (RTSs) have a platinum resistance element (Pt 100 or 50 ) in

More information

Model PH8EFP KCl Filling type ph Sensor

Model PH8EFP KCl Filling type ph Sensor User s Manual Model PH8EFP KCl Filling type ph Sensor R 6th Edition Blank Page INTRODUCTION This manual covers the PH8EFP KCl Filling type ph Sensor. Other related items are described in the following

More information

SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E. FILE No. A

SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E. FILE No. A FILE No. A11-017 AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL Model name: RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E PRINTED IN JAPAN, Jan. 2012, TDOC CONTENTS 1. Safety Precautions..................................3

More information

Specification for Remanufacture Alstom Model 5 Switch Machine

Specification for Remanufacture Alstom Model 5 Switch Machine Alstom Model 5 Switch Machine This page is intentionally left blank for the purpose of double sided printing Alstom Model 5 Switch Machine - Page 2 of 9 - (262) 658-3590 TABLE OF CONTENTS 1 SCOPE AND INTENT.5

More information

Integrated temperature test and calibration bench Model CBS-SC4000

Integrated temperature test and calibration bench Model CBS-SC4000 Calibration technology Integrated temperature test and calibration bench Model CBS-SC4000 WIKA data sheet CT 92.33 Applications Testing and calibration of temperature measuring instruments such as: - Mercury

More information

Model PH8EFP KCl Filling type ph Sensor

Model PH8EFP KCl Filling type ph Sensor User s Manual Model PH8EFP KCl Filling type ph Sensor R 7th Edition Blank Page INTRODUCTION This manual covers the PH8EFP KCl Filling type ph Sensor. Other related items are described in the following

More information

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free TX900 Microwave Leakage Detector 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Users Manual TX900 Microwave Leakage Detector

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

Type D0800. Bantam Cartridge Holder OPERATION MANUAL AND PARTS LIST SERIES 494. Mo de l # Vo ltag e D D /12/08

Type D0800. Bantam Cartridge Holder OPERATION MANUAL AND PARTS LIST SERIES 494. Mo de l # Vo ltag e D D /12/08 Type D0800 Bantam Cartridge Holder OPERATION MANUAL AND PARTS LIST SERIES 494 Mo de l # Vo ltag e D0800 120 D0805 240 60119 3/12/08 Table of Contents Safety Information...3 Alert Signals...3 Warnings...3

More information

FX2N-2LC SPECIAL FUNCTION BLOCK

FX2N-2LC SPECIAL FUNCTION BLOCK SPECIAL FUNION BLOCK USER S GUIDE JY992D8561E Cautions on Safety (Make sure to read this paragraph before using the unit.) Thoroughly read this manual, a separate USER S MANUAL and all attached documents

More information

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS CP-UM-306E ECM3000 Control Motor User's Manual WARNING Be sure to turn the power OFF before mounting, removing, or wiring the ECM3000 or opening the cover. Touching electrically charged parts such as power

More information

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date: ISP-500B Oil-free Scroll Vacuum Pump Instruction Manual View our inventory Serial Number: Record of Pump Information Purchase date: In Service date: Dealer information: IM-500B 1/3/07 Page 1 of 26 Important

More information

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004 U00X ULTRASONIC LEVEL SWITCH INSTALLATION AND OPERATIONS MANUAL Ultrasonic Liquid Level Switches For Non-Hazardous Locations For Models: U002, U003 & U004 READ THIS MANUAL PRIOR TO INSTALLATION This manual

More information

FR1118- P10. User s Manual

FR1118- P10. User s Manual FR1118- P10 User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury.

More information

COMPOSITE ACCESS COVER INSTALLATION GUIDE

COMPOSITE ACCESS COVER INSTALLATION GUIDE COMPOSITE ACCESS COVER INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information

More information

Tina 4A Connection block

Tina 4A Connection block Original instructions Tina 4A Connection block Instructions valid for versions of the product from ver. H ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read

More information

Filterpack FR-BFP2-(H)0.4K to (H)15K

Filterpack FR-BFP2-(H)0.4K to (H)15K INVERTER INSTRUCTION MANUAL FR-BFP2-(H)0.4K to (H)15K 1. Product Checking... 1 2. Applicable Inverter... 1 3. Installation... 2 3.1 Inverter Installation (installation of the )...2 4. Wiring... 4 5. Main

More information

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to LM-100 LM-120 Light Meters Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com LM-100 / LM-120 Light Meters English Users Manual LM100_Rev002 2008 Amprobe Test Tools.

More information

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973) SERVICE MANUAL STARTER Portable Meter ST300 ST300C ST300D ST400D Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ 07054 (973) 377-9000 SERVICE MANUAL STARTER Portable Meter ST300 ST300C ST300D

More information

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user. CP-UM-5706E Product by Germany s Elster GmbH High-Performance Gas Solenoid Valve for Industrial Applications GV-A User's Manual WARNING Before wiring, installing, or removing the unit, be sure to turn

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CC with Built-in Microcomputer and Digital Display Withstands a pressure of 49 kpa and highly reliable. Incorporates a two-turn pressure adjuster ensuring easy pressure setting.

More information

Pressure Transmitter

Pressure Transmitter Specifications/Instructions Pressure Transmitter General Model PY7100A pressure transmitter is a small pressure transmitter using a semiconductor strain gauge. It detects the pressure of chilled/hot water,

More information

Tina 11A Connection block

Tina 11A Connection block Original instructions Tina 11A Connection block ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION 11/05 Form #273 OPERATING INSTRUCTION MODEL 4105 Disital Earth Resistance Tester 2150 joshua's Path, Suite 302, Hauppauge, NY 11788 Phone : 1-800-645-5398 or 1-639-231-7050 Fax : 1-639-434-3128 E-mail

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor ABB MEASUREMENT & ANALYTICS DATA SHEET 7835 Hydrazine monitor 2 78 35 H YDR AZ I N E MON I TOR DS / 78 3 5-E N RE V. L Measurement made easy Advanced transmitter Auto-ranging with remote range indication

More information

AS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g.

AS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g. Speed Controller with One-touch Fittings In-line In-line Type y Easo t use RoHS Brass Stainless steel Reduces flow setting time! Push-lock type Knob O.D.: Almost doubled! Easy to lock ø9.4 Unlock ø5 Lock

More information

PHscan10S Pocket ph Tester Instruction Manual

PHscan10S Pocket ph Tester Instruction Manual PHscan10S Pocket ph Tester Instruction Manual BANTE INSTRUMENTS CO., LTD PHscan10S Pocket ph Tester 1 Thank you for selecting the PHscan10S pocket ph tester. This manual provides a step-by-step guide to

More information

COMPRESSED AIR LOADER MODEL: AL-1

COMPRESSED AIR LOADER MODEL: AL-1 COMPRESSED AIR LOADER MODEL: AL-1 Document: AL-1 IM 10-22-2011 TABLE OF CONTENTS Important Notices and Precautions 3 Quick Installation 4 Product Description 4 Principle of Operation 5 Unpacking and Inspection

More information

FX-1100 Series MASS BURETTE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD.

FX-1100 Series MASS BURETTE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD. FX-1100 Series MASS BURETTE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD. 1. This document may not be reproduced, in whole or part, in any form or by any means without the prior written permission

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS Table of Contents Safety... 2 Specifications... 3 Functions... 4 Operation... 5 Maintenance... 7 Warranty... 7 SAFETY SPECIFICATIONS OPERATION MAINTENANCE WARNING SYMBOLS AND DEFINITIONS This is the safety

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

Galaxy Receiving and Unpacking 09/

Galaxy Receiving and Unpacking 09/ Galaxy 5500 20 120 kva 400 V Receiving and Unpacking 09/2015 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS

More information

General Specifications

General Specifications General Specifications Model SS400 MLSS Analyzer GS 12E6A1-E General The Model SS400 MLSS Analyzer is a measuring system best suited to continuously and consistently measure the concentration of mixed

More information

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA) Instruction Manual Installation Manual Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA) Thank you for your purchase of Teral (Volute) Submersible Turbine Pump. To the customers

More information

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual 25500181 Rev. A0 415 Printed in U.S.A. Copyright 2015 Federal Signal Corporation Limited Warranty The Alerting and Notification Systems

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Please read this manual completely before installing or operating this unit! BAGR7 Blue Air reserves

More information

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter Basic performance oriented general vacuum ejector unit Series Nozzle diameter: ø.5, ø, ø1. acuum switch and vacuum break valve, etc. are unitized, so types matching the work purpose is selectable. Features

More information

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model User's Manual High Voltage Megohmmeter Analog Insulation Tester plus AC Voltage and Continuity Tests Model 380353 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects

More information

EVS RP6020. Instruction Manual

EVS RP6020. Instruction Manual Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.

More information

Lumitester PD-20 Control Kit

Lumitester PD-20 Control Kit 日本語による取扱説明は 17 ページからとなります Lumitester PD-20 Control Kit Operation manual Thank you for purchasing the Lumitester PD-20 Control Kit. To use this kit safely and correctly, read this operation manual carefully

More information

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by: Storage System Ultrasound Probe Cabinet Operator's Manual Manufactured by: CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA 319.248.6757 / 800.445.6741 WWW.CIVCO.COM Copyright 2018 All

More information

CYCLONE PocketMax PP-1000 Compact Battery Pack for Portable Flashes. User Manual

CYCLONE PocketMax PP-1000 Compact Battery Pack for Portable Flashes. User Manual CYCLONE PocketMax PP-1000 Compact Battery Pack for Portable Flashes User Manual Thank you for choosing Bolt. The PocketMax battery pack will provide up to 1,000 flashes at full power and boost the recycle

More information

Instruction Manual. Models FD30 / PB30. Fittings for the DO30G. IM 12J06K04-E-E 6th edition

Instruction Manual. Models FD30 / PB30. Fittings for the DO30G. IM 12J06K04-E-E 6th edition Instruction Manual Models FD30 / PB30 Fittings for the DO30G 6th edition 2 Table of contents 1. Introduction...3 2. Unpacking and checking...3 3. Warranty and service...3 4. Genral specifications...4 4-1.

More information

KEWTECH. KT56 digital multi function tester. Instruction manual

KEWTECH. KT56 digital multi function tester. Instruction manual KEWTECH KT56 digital multi function tester Instruction manual Contents 1 Safety Notice 1 2 Features and Principles of Measurement 3 3 Introduction 6 4 Specifications 7 5 Instrument layout 9 6 Operating

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE TABLE OF CONTENTS SECTION 1 General Information: Model Description Pg 2 Serial Numbers Description of Operation SECTION 2 Safety Instructions: Pg

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and Safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe

More information

OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200

OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200 OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200 ISSUE 4 April 2007 TABLE OF CONTENTS Page 1.0. GENERAL INFORMATION 2 1.1. DEFINITION 2 1.2. PRINCIPE OF OPERATION 2 2.0. TECHNICAL DESCRIPTION

More information

SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER

SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER SELKIRK CORP MODEL G - CHIMNEY LINER These instructions are supplemental to the General Installation Instructions for Selkirk Model G, PS, IPS and ZC Single Wall, Double Wall Air & Fiber Insulated Positive

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide

More information

/OVAL OPERATION MANUAL. Eggs DELTA Pulse. Vortex Flow Monitor MODEL : FLP? L A G 1 2 FLP? L?

/OVAL OPERATION MANUAL. Eggs DELTA Pulse. Vortex Flow Monitor MODEL : FLP? L A G 1 2 FLP? L? Vortex Flow Monitor /OVAL Eggs DELTA Pulse OPERATION MANUAL MODEL : FLP? L A G 1 2 FLP? L? SA G 1 2 FLP? L? G 1 2 P N A Every Sparling/OVAL vortex flow monitor Eggs DELTA Pulse is fabricated and shipped

More information

User Manual Pocket Pro, Pro + ph

User Manual Pocket Pro, Pro + ph User Manual Pocket Pro, Pro + ph DOC022.52.80394 1 Specifications Specification Dimensions (W x D x H) Enclosure rating Weight Specifications are subject to change without notice. Details 37 x 30 x 170

More information

Digital Flow Switch (Sensor Part) Operation Manual

Digital Flow Switch (Sensor Part) Operation Manual Digital Flow Switch (Sensor Part) Operation Manual For Air PF2A 50/5 Series PF2A 5/ 52/ 55 Series For Water PF2W /520/50 Series PF2W 5 Series For Water (High Temperature Fluid Type) PF2W T/520T/50T Series

More information

INSTRUCTION & INSTALLATION

INSTRUCTION & INSTALLATION INSTRUCTION & INSTALLATION MANUAL MODELS: CCL-eHOME T1C16 CCL-eHOME T1C32 CCL-eHOME T2C16 CCL-eHOME T2C32 WALLBOX ehome SERIES WALLBOX ehome Instruction and Installation manual This document is copyrighted,

More information

ECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED

ECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED ECscan10H Pocket Conductivity Tester Instruction Manual BANTE INSTRUMENTS LIMITED ECscan10H Pocket Conductivity Tester 1 Introduction Thank you for selecting the ECscan10H pocket conductivity tester. This

More information

INSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08

INSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08 RoHS READ THE INSTRUCTION MANUAL BEFORE USING INSTRUCTION MANUAL MANOSTAR TRANSMITTER No. TR--E08 1-2-,Nishi-shiriike-cho,Nagata-ku,Kobe,Hyogo 65-001 JAPAN TEL. +81(78)-61-6000 FAX. +81(78)-61-6020 INTRODUCTION

More information

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

717 Series. Pressure Calibrators. Instruction Sheet. Introduction Introduction 717 Series Pressure Calibrators Instruction Sheet The Fluke 717 Series Pressure Calibrators are compact, battery-powered, 5-digit instruments that perform the following calibration and measurement

More information

Updated: October 2012

Updated: October 2012 T: (630) 794-5100 EMERGENCY POWER FUEL SYSTEMS Earthsafe Systems, Inc. 7320 S. Madison Willowbrook, IL 60527 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com Updated: October 2012 The information

More information