1 HF2 Gauge Installation Guide Scantech

2 2

3 Contents Property Note... 5 Conventions...5 Safety Precautions...5 Contact... 7 Placing the Gauge in Its Allocated Space... 9 Positioning the Gauge...9 Moving the Gauge... 9 Stabilizing the Gauge Connection to Power Supply External connections...14 Pneumatic Connection...17 Specifications...19 Mechanical specifications...19 Front View...19 Side View Mounting Dimensions Environmental, Electrical and Operational Specifications...20 Transport Storage

4 4

5 Property Note This document contains information proprietary to Scantech. It may not be copied or transmitted by any means, disclosed to others, or stored in any retrieval system or media without the prior written consent of Scantech or one of its authorized agents. The information contained in this document is, to the best of our knowledge, entirely correct. However, Scantech assumes no responsibility or liability arising out of the application or use of any information, product, service or example described in this document. Scantech reserves the right to change, modify, or improve this document or the product described herein, as seen fit by Scantech at any time, without further notice. Scantech customers are advised to obtain the latest version of device specifications before relying on any published information and before placing orders for products or services. Conventions The following conventions are used in this manual Note NOTE This symbol denotes additional information. The precautions listed in this note are advisable. Caution TAKE CARE This symbol calls attention to a condition or possible situation that can damage or destroy the product or the user s work. You must take the precautions listed in the warning. HOT SURFACE This warning indicates a hot surface. Warning To prevent fingers or other body parts from being burned, you must take the precautions listed in the warning. Danger HIGH VOLTAGE This symbol and title warn of hazards due to electrical shocks (> 60V) when touching products or parts of them. Failure to observe the precautions indicated and/or prescribed by the law may endanger the user's life/health and/or result in damage to the material. Unless otherwise stated, do not perform maintenance when the sytem is powered. Safety Precautions DO NOT OPERATE, SERVICE, OR REPAIR THIS EQUIPMENT UNLESS YOU FULLY UNDERSTAND ALL APPLICABLE SECTIONS OF THIS MANUAL. DO NOT ALLOW OTHERS TO OPERATE, SERVICE, OR REPAIR THIS EQUIPMENT UNLESS THEY FULLY UNDERSTAND ALL APPLICABLE SECTIONS OF THIS MANUAL. 5

6 HF2 Property Note FAILURE TO FOLLOW ALL APPLICABLE WARNINGS AND INSTRUCTIONS MAY RESULT IN SEVERE PERSONAL INJURY OR PROPERTY DAMAGE. Warning Sign Description Attention: This icon indicates the risk of death or serious personal injury may result if precautions are ignored. High Voltage: This icon indicates High Voltage exists inside the cover. Opening the cover improperly may result in personal injury or device failure. Ionizing Radiation: This icon indicates Ionizing Radiation may exist in the area; improper maintenance may cause exposure to radiation and be a health hazard. Entanglement: This icon indicates moving parts can crush and cut. Lock out power before servicing. Independent grounding should be provided to the system. DO NOT use the cover of other machines as grounding for the system. DO NOT use tapped piping or building walls as grounding for the system. FAILURE TO FOLLOW THIS PRECAUTION MAY RESULT IN SEVERE PERSONAL INJURY OR EQUIPMENT DAMAGE. The system is NOT a waterproof design. DO NOT expose this equipment to environments or areas exposed to water or other liquids. Transportation/installation of this equipment on site, power supply connection to this equipment and commission of this equipment should be performed under supervision of a SCANTECH Technician. TURN OFF electrical power to equipment before opening the cabinet door or the detector head cover for maintenance purposes. There are HIGH VOLTAGE devices inside the detector heads. ONLY professional personnel with proper training can open the detector heads. 6

7 HF2 Property Note All the moving parts except detector heads are protected by covers; DO NOT operate the equipment when the covers or other protective devices are removed. DO NOT place any body part near or on moving parts. Although radiation testing by an authorized organization confirms that during normal operation the equipment's x-ray emissions are much lower than a level considered harmful, personnel should not expose body parts directly under the x-ray beam Contact Scantech S.A.S. Savoie Technolac BP Le Bourget du Lac FRANCE Tel: support@scantech.fr 7

8 HF2 Property Note 8

9 Placing the Gauge in Its Allocated Space Positioning the Gauge For full usability of the gauge, some conditions must be checked. 1. Ensure that the air curtain fans blow in the opposite direction to the measured material flow direction. 2. Ensure that the scanning limit of the gauge covers the full range of the measured material width. 3. Note: Some equipments such as corona treaters emit ozone. Exposure to ozone causes severe corrosion to the equipment's mechanical and electronic components. Ensure that this type of equipment is located downstream and at least 3 meters distance away from Scantech's equipment 4. Ensure that the gauge is protected from exposure to high humidity, liquids, and dirty environments. 5. Ensure that there is enough space around the equipment to open the cabinet and remove the covers of beams. 6. Ensure that the emergency stop button and the main power breaker remain accessible after installation. Moving the Gauge The gauge must be transported with a lifting beam, in order to avoid permanent damage to the frame. Before you begin a lifting beam slings 1. Ensure the doors are closed and secured. 2. Ensure the light tower is removed. 3. Ensure the heads are positionned near the closet. 4. Pass the slings in the eye rings located at the top of the frame. 9

10 HF2 Placing the Gauge in Its Allocated Space 5. Danger CRUSH HAZARD If not properly secured, the gauge may fall The lifting engine must be controlled by properly qualified personnel Use only adequate slings and equipment. Please refer to mechanical specification table for the weight of your scanner Caution DAMAGE Usage of unproper tool for moving the gauge can cause permanent damage to the frame of the gauge. DO NOT move the gauge with a fork lift under the gauge frame. Lift the gauge to the installation site. The distance L between the two slings must respect the following formula: L > (Length - 90 mm) For a model LF mm gauge: L > = 2410 mm. The distance L between the two slings must be greater than 2410 mm. 10

11 HF2 Placing the Gauge in Its Allocated Space Stabilizing the Gauge The Gauge is provided with mounting feets which must be adjusted to the requirements of the line. Before you begin 6 M16 bolts 6 M8 bolts 1. Ensure that the connection components to which the gauge is attached are adapted. They must be: level vibration-stiff free from paint, rust, grease and oil and have a plane machined surface. 2. Ensure that the process guide rolls guide the measured material parallel to the plane of the passline of the gauge. 11

12 HF2 Placing the Gauge in Its Allocated Space 3. Obtain four bolts and washers to mount the gauge to the connection. Scantech does not provide mounting bolts. 4. Position the gauge over the pre-drilled holes. 5. Adjust the measured material pass line to be in the middle between the upper and lower heads by adjusting the leveling screws at the base of the gauge. 12

13 Connection to Power Supply This procedure describes the steps to connect the equipment to the mains supply. Before you begin Danger ELECTRIC SHOCK Lethal electrical levels are present on mains power. Only properly qualified personnel are permitted to make the electrical installation. Mains power must be cut off before the start of this task. You must wear individual protection equipments to perform this task. Do not use detachable mains supply cord to power the equipment. Danger ELECTRIC SHOCK The gauge should be provided with independent grounding. Failure to provide correct grounding may result in severe personal injury or equipment damage. Do not use the covers of other machines as grounding for the system. Do not use tapped pipes or walls of building as grounding for the system. In addition to these practices, some localities and industries require applicable electrical and safety codes, laws and standards. 1. Ensure that the supply voltage details on the nameplate are correct for the plant. 2. Ensure that the equipment does not share the power supply with other equipments with high frequency harmonics or highly magnetic fields. 3. Open the door of the cabinet of the gauge. 4. Pass the power cable through a cable gland at the bottom of the cabinet. 5. Connect the power to the terminal XC1 as follows Terminal Color Name XC1-N BLUE NEUTRAL XC1-L BLACK PHASE XC1-GND YELLOW/GREEN GROUND 6. Secure the cable with the cord anchorage. 13

14 HF2 Connection to Power Supply External connections Terminal Mark Description Input/ Output Specification XC3-17 XC3-18 Length Tick +24V Length Tick Input Input Resistance: 10 kohms Max input voltage: 28 V Max Freq: 100 Hz Protection: 0.1 A Dry contact NO between 24V and input XC3-19 XC3-20 Roll Change +24V Roll Change Input Input Resistance: 10 kohms Max input voltage: 28 V Max Freq: 100 Hz Protection: 0.1 A Dry contact NO between 24V and input XC3-21 XC3-22 Web Break +24V Web Break Input Input Resistance: 10 kohms Max input voltage: 28 V Max Freq: 100 Hz Protection: 0.1 A Dry contact NO between 24V and input XC3-23 XC3-24 Web Break +24V Web Break Input Input Resistance: 10 kohms Max input voltage: 28 V Max Freq: 100 Hz Protection: 0.1 A Dry contact NO between 24V and input XC3-25 XC3-26 Spare +24V Spare Input Input Resistance: 10 kohms Max input voltage: 28 V Max Freq: 100 Hz Protection: 0.1 A Dry contact NO between 24V and input XC3-27 GND 0V Output Ground XC3-28 N/C XC3-29 XC3-30 Alarm Alarm Output Voltage: 24V Max output current: 150 ma XC3-31 XC3-32 Spare Digital Output Spare Out Output Voltage: 24V Max output current: 150 ma XC3-33 XC3-34 Analog Line Speed Analog Speed 0V Input Input type: Voltage Max voltage range: 0-10V Max Freq: 10 khz Protection: Seperate Voltage Regulator 14

15 HF2 Connection to Power Supply Terminal Mark Description Input/ Output Specification XC3-35 XC3-36 Analog Spare Input Analog Spare Input 0V Input Input type: Voltage Max voltage range: 0-10V Max Freq: 10 khz Protection: Seperate Voltage Regulator XC3-37 XC3-38 Average Average 0V Output Output type: Voltage Max voltage range: 0-10V Max Freq: 10 khz Protection: Seperate Voltage Regulator XC3-39 XC3-40 Analog Spare Output Analog Spare 0V Output Output type: Voltage Max voltage range: 0-10V Max Freq: 10 khz Protection: Seperate Voltage Regulator 15

16 HF2 Connection to Power Supply 16

17 Pneumatic Connection Compressed air supply is required for the Vortex cooling system. The user should provide compressed air that is free of oil, water, or contamination. Caution PERFORMANCE DEGRADATION Unfiltered compressed air with oil/water/dust contamination will degrade the cooling performance of the system and may induce greater consumption of air. Provide only filtered air. Name Pressure Max Capacity Specification 0.4MPa < P < 0.6 MPa 24m³/h 17

18 HF2 Pneumatic Connection 18

19 Specifications Mechanical specifications Front View Side View Mounting The gauge frame must be mounted on a metal platform or metal support on a concrete floor. 19

20 HF2 Specifications Dimensions Type Mass (kg) Length (mm) Width (mm) Height (mm) HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF HF Environmental, Electrical and Operational Specifications Operating Temperature 0 C to 50 C Relative Humidity 20-80% non-condensing Maximum operating altitude 2000 meters above sea Electrical Supply AC V 400VA 50-60Hz single phase Network Communication TCP/IP over 100Mb/s CAT5E ethernet cable Atmosphere without corrosive gases or dust Transport You should observe the following criteria for transportation: Don't open packing until on final position Don't tilt the packing boxes for more than 15 during handling. Follow the instruction labels "up" and "down" during transit. Don't use a forklift truck for moving the gauge box. Use an overhead crane with sufficent capacity. 20

21 HF2 Specifications Lift the packing boxes only at the specifically identified lifting points. Lifting devices such as eyebolts, slings, and spreaders must be rated, selected, and used for the entire load being lifted. Avoid heavy pressure and jolting of the boxes. Transportation conditions should conform to the requirements of the packing boxes and of the modules regarding their environmental conditions. Warning CRUSH HAZARD The packing boxes can be heavy.if not properly secured, they may fall Use proper lifting methods and wear steel-toed shoes at all times. Storage You should store the gauge according to the following specification until mounted finally: In enclosed dry rooms Protected from dust At a maximum ambient temperature of 50 C Free from vibration to avoid bearing damage The cabinet must be closed and the head covers must be in place. Provide the covering so that condensation water, if any, can flow off. Place the equipment on suitable support or in shelves to prevent effects of soil moisture. If seaworthy packed, do not open or damage this packing during transport or storage. 21

22 HF2 Specifications 22

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input 208-240 Vac Output 208-120 Vac User Guide UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY

More information

Rotary - TR/TRT/T5C - Installation

Rotary - TR/TRT/T5C - Installation Haas Technical Documentation Rotary - TR/TRT/T5C - Installation AD0005 Rev K Applies to machines built from: January, 2007 Scan code to get the latest version of this document Translation Available Rotary

More information

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual DC power supply connect to VF-AS1/PS1 Optional initial charger Instruction manual NOTE 1. Make sure that this instruction manual is delivered to the end user of the optional initial charger. 2. Read this

More information

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

Galaxy VM. Battery Breaker Box Installation 09/

Galaxy VM. Battery Breaker Box Installation 09/ Galaxy VM Battery Breaker Box Installation 09/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred

More information

TOD-BCU-PNUS2. Installation Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System) For Installation Company Use

TOD-BCU-PNUS2. Installation Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System) For Installation Company Use For Installation Company Use For Maintenance and Inspection Use Model TOD-BCU-PNUS2 Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System) Installation Manual The content of this Installation

More information

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.: Operating manual HDA eco Box 12/24V DC Automatic Dispenser Item No.: 110 500 900 Translation of the original operating manual Important! Copyright The operating manual is always to be read before commissioning

More information

Powerware Vdc Extended Battery Cabinet User s Guide.

Powerware Vdc Extended Battery Cabinet User s Guide. Powerware 9125 48 Vdc Extended Battery Cabinet User s Guide www.powerware.com FCC Part 15 Class A EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class A digital

More information

Cougar B Series Electric Vibrators 3 Frame

Cougar B Series Electric Vibrators 3 Frame Cougar B Series Electric Vibrators 3 Frame Go to Cougar B Series Electric Vibrators web page Operator s Manual M3929 Important MARTIN ENGINEERING HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION

More information

Butterfly valves Figure 56 Installation & Maintenance Instructions

Butterfly valves Figure 56 Installation & Maintenance Instructions KEYSTONE Please read these instructions carefully This symbol indicates important messages and safety instructions. Hazard potentials: disregarding of instructions improper use of product insufficiently

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation User s Manual 700938 Power Supply Yokogawa Electric Corporation 3rd Edition Introduction Revisions Thank you for purchasing the 700938 Power Supply. This Instruction Manual contains useful information

More information

EJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions

EJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions EJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 3009/16 en Ed.02.2016 Read these Operating Instructions before performing any transportation, installation, commissioning, maintenance or

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are

More information

EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE

EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the

More information

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type AS Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx

More information

ION JET NOZZLE NIH-55

ION JET NOZZLE NIH-55 ION JET NOZZLE NIH-55 INSTRUCTION MANUAL - Read this instruction manual and make sure you thoroughly understand its contents before attempting to operate, inspect or service this product. - The users and

More information

FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE

FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information

More information

FBD-NT Press Brake Installation Guide

FBD-NT Press Brake Installation Guide FBD-NT Press Brake Installation Guide Summary...2 Environmental conditions...2 Power supply...2 Machine installation...3 Location...4 Carrying...5 Using a crane...5 Using rollers...6 Foundation...7 Cleaning...7

More information

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4 Braking Resistor Units 3G3IV-PCDBR2 B/4 B Braking Units Thank you for choosing an OMRON Braking Resistor Unit and Braking Unit. Proper use and handling

More information

ANTI-SYPHON VALVE INSTALLATION GUIDE

ANTI-SYPHON VALVE INSTALLATION GUIDE ANTI-SYPHON VALVE INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information contained

More information

Cougar B Series Electric Vibrators 4 Frame

Cougar B Series Electric Vibrators 4 Frame Cougar B Series Electric Vibrators 4 Frame Go to Cougar B Series Electric Vibrators web page Operator s Manual M3930 Important MARTIN ENGINEERING HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION

More information

MANUAL. Single charger

MANUAL. Single charger MANUAL Single charger HST-PR-2830 & HST-PR-2830USA for HS-Technik batteries HST-PR-18xx HST-PR-14xx issue date: November 2016 Table of contents Page 1. Basic information...3 1.1. Purpose of this document...3

More information

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of

More information

User s Manual Power Supply IM E. 5th Edition

User s Manual Power Supply IM E. 5th Edition User s Manual 700938 Power Supply 5th Edition Thank you for purchasing the 700938 Power Supply. This user s manual contains useful information about the instrument s functions and operating procedures

More information

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter

More information

PMA INTAKE FILTER SCREEN INSTALLATION GUIDE

PMA INTAKE FILTER SCREEN INSTALLATION GUIDE PMA INTAKE FILTER SCREEN INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information

More information

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Installation Guide WBP-Box-IEN103320 IMEN-WBP-BOX Version 2.0 EN SMA Solar Technology AG Table of Contents Table of Contents

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Intelligent Flow Measurement Your Sole Source for Badger Differential Producers Worldwide 6 Blackstone Valley Place, Lincoln RI 02865-1162 Ph: 401 334 1170 Fx: 401 334 1173 Em: solutions@wyattflow. Installation,

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s.   PEGAS E Smart Manual EN 04 WELDING INVERTER PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL PEGAS 160-200 E Smart Manual EN 04 2/12 CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL DATA...

More information

HST-BL-2830MS & HST-BL-2830MS-USA

HST-BL-2830MS & HST-BL-2830MS-USA HST-BL-2830MS & HST-BL-2830MS-USA Release date: 02/2017 High - System - Technik Im Martelacker 12 D-79588 Efringen-Kirchen Phone 0 76 28-91 11-0 Fax 0 76 28-91 11-90 E-Mail: info@hs-technik.com Web: www.hs-technik.com

More information

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake ZJ-267A Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake Instruction Manual Table of Contents Cautions on Safety - - - - - - - - - - - - - - - - - 1 1. Cautions before use - -

More information

Galaxy Receiving and Unpacking 09/

Galaxy Receiving and Unpacking 09/ Galaxy 5500 20 120 kva 400 V Receiving and Unpacking 09/2015 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 050 NPK 0100 Operating and Installation Instructions Read and observe these Operating and Installation Instructions! KNF Neuberger GmbH Alter Weg 3 D-79112

More information

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4 User's Guide Contents Page 1 - SAFETY SYMBOLS USED 3 2 - PROPER USE 3 3 - SAFETY PRECAUTIONS 3 Possible dangers if the safety precautions are not observed 3 Safety at work 3 Safety aspects for the user

More information

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 040709 2003 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter

More information

High Frequency SineWave Guardian TM

High Frequency SineWave Guardian TM High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation

More information

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM _ M MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM User's MANUAL Code: MVM Version: 01-BF Date: OCT 2005 Page 1/10 _ 1. INTRODUCTION Before starting to use your Energic plus MVM battery charger, please take

More information

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n dv/dt Filter Series A 440-600 VAC USER MANUAL PART NO. INSTR - 019 REL. 041119 2004 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dv/dt Filter is designed

More information

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual SDM320D / SDM320A DIN Rail Single Phase Two Wire Energy Meter with S0 Pulse Output (Four modular) User Manual ------------------- 1.1 Safety instruction 1.2 Introductions 1.3 Performance criteria 1.4 Specifications

More information

WATERFLUX 3070 Quick Start

WATERFLUX 3070 Quick Start WATERFLUX 3070 Quick Start Battery powered electromagnetic water meter Electronic Revision ER 4.3.0_ up to ER 4.3.4_ (SW.REV 4.2.2_ up to 4.2.5_) KROHNE CONTENTS WATERFLUX 3070 1 Safety instructions 4

More information

Owner s Manual. ELECTRIC WIRE ROPE HOIST and TROLLEY RH SERIES

Owner s Manual. ELECTRIC WIRE ROPE HOIST and TROLLEY RH SERIES EFFECTIVE: September 25, 2007 Owner s Manual ELECTRIC WIRE ROPE HOIST and TROLLEY RH SERIES 2 Ton through 20 Ton Capacity Product Code and Serial Number WARNING This equipment should not be installed,

More information

COMPOSITE ACCESS COVER INSTALLATION GUIDE

COMPOSITE ACCESS COVER INSTALLATION GUIDE COMPOSITE ACCESS COVER INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information

More information

RT Series Battery Pack UL for RT 6 and 10 kva UPS UL. Extended Battery Pack. User Guide

RT Series Battery Pack UL for RT 6 and 10 kva UPS UL. Extended Battery Pack. User Guide RT Series Battery Pack UL for RT 6 and 10 kva UPS UL RT 06E 20-007-120 BPX-B-UL RT 10E 20-009-120 BPX-B-UL Extended Battery Pack User Guide UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO

More information

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017.

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017. Galaxy VM Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks

More information

Preparing the Site. Information About the Site Requirements CHAPTER

Preparing the Site. Information About the Site Requirements CHAPTER 2 CHAPTER This chapter describes the basic site requirements that you should be aware of as you prepare to install your Cisco Nexus 7000 Series switches. This chapter includes the following sections: Information

More information

OPTIFLUX 2000 Quick Start

OPTIFLUX 2000 Quick Start OPTIFLUX 2000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS OPTIFLUX 2000

More information

Differential Pressure Transmitter

Differential Pressure Transmitter Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused

More information

Assembly instructions

Assembly instructions Please carefully read the assembly instructions before beginning the installation, operation and maintenance of the solar facility. Noncompliance could cause injury to persons or damage to the equipment.

More information

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds for assembly, commissioning and maintenance of valves and hydraulic manifolds 110210_general_operating_manual 07.2018 Table of contents Contents Page Important information 2 Important safety instructions

More information

Galaxy kva 3:3 and 3:1. Receiving and Unpacking. 380/400/415 and 208/220 V 04/2016.

Galaxy kva 3:3 and 3:1. Receiving and Unpacking. 380/400/415 and 208/220 V 04/2016. Galaxy 3500 10-40 kva 3:3 and 3:1 Receiving and Unpacking 380/400/415 and 208/220 V 04/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider

More information

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTION MANUAL LEVEL SWITCH LV-300 No.LV31JE2 2008.05 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. Safety Precautions (Be sure to

More information

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation User s Manual 701934 Power Supply Yokogawa Electric Corporation 2nd Edition Foreword Revisions Thank you for purchasing the 701934 Power Supply. This user's manual contains useful information about the

More information

Installation and Service Manual for RV33, RV332, RV75, RV752, RV100, RV1002

Installation and Service Manual for RV33, RV332, RV75, RV752, RV100, RV1002 Rotary Vane Compressors RV Series Installation and Service Manual for RV33, RV332, RV75, RV752, RV100, RV1002 Thank you for purchasing the Stratus RV series rotary vane compressor. This instruction manual

More information

Intelivalve Solenoid Pinch Valve

Intelivalve Solenoid Pinch Valve Intelivalve Solenoid Pinch Valve Installation and Operation Manual Manufacturer: Acro Associates, Inc. 1990 A Olivera Road Concord, CA 94520 USA Phone: +1 (925) 676 8828 Fax: +1 (925) 680 8113 Email: info@acroassociates.com

More information

Event Spot WW Triac. User Manual. Order codes: LEDJ237 - Black Housing LEDJ237A - White Housing

Event Spot WW Triac. User Manual. Order codes: LEDJ237 - Black Housing LEDJ237A - White Housing Event Spot WW Triac User Manual Order codes: LEDJ237 - Black Housing LEDJ237A - White Housing Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!

More information

Galaxy 300 Battery Breaker Kit G3HTBKIT1

Galaxy 300 Battery Breaker Kit G3HTBKIT1 Installation 990 5739 001 03/2016 990 5739 001 Galaxy 300 Battery Breaker Kit G3HTBKIT1 What s in This Document Important Safety Instructions SAVE THESE INSTRUCTIONS...1 Safety Precautions...2 Specifications...4

More information

CONTENTS 0.005 0.004 0.003 0.002 0.001 0 SE15 SE23SC23 SE30SC30 SE45SC45 0 200 400 600 800 1000 Category Option Manufactured by order (Note 8) Item SG series SE series SC series Motor Intermediate

More information

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy NorthStar TM brand Instruction Manual SLIM Tach SL56 1.125 Thru-Shaft Diameter Magnetoresistive Encoder Designed for GE Wind Energy Patent Pending *791-1061-00* Rev. B Page 2 Table of Contents Chapter/Paragraph/Illustration

More information

Assembly and Maintenance Manual Type RSBW

Assembly and Maintenance Manual Type RSBW Assembly and Maintenance Manual Type RSBW Hatschekstr. 36 69126 Heidelberg Germany Tel +49(0)6221 30470 Tel +49(0)6221 304731 info@stieber.de www.stieber.de Stieber Clutch Date of issue: 16/03/2017 GB

More information

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Keystone Butterfly valves ParaSeal Installation and maintenance instructions Before installation these instructions must be fully read and understood Please read these instructions carefully Hazard potentials: disregarding of instructions improper use of product insufficiently

More information

Top Drive System Installation and Commissioning Manual

Top Drive System Installation and Commissioning Manual TDS-1000A Top Drive System Installation and Commissioning Manual SM01040 General Information Conventions.............................. 1-3 Notes, Cautions, and Warnings......................... 1-3 Illustrations.........................................

More information

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software User Manual Thank you for purchasing the Defender 650/1200/1600. It is designed to provide safe and reliable power protection to your precious electronics equipment. Before you start using the product,

More information

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3 Atlantic Battery Systems 1065 Market Street Paterson, NJ 07513 Phone: (800) 875-0073 Fax: (973) 523-2344 sales@atbatsys.com www.atbatsys.com SOS1 SOS2 SOS SERIES Spares On Site Battery Cabinet Installation

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

I. Safety precautions

I. Safety precautions . Safety precautions The items described in these instructions and on the inverter itself are very important so that you can use the inverter safely, prevent injury to yourself and other people around

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

The Efficient Solution for Pipetting up to 100 ml at once! USER'S GUIDE

The Efficient Solution for Pipetting up to 100 ml at once! USER'S GUIDE The Efficient Solution for Pipetting up to 100 ml at once! This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the User s Guide, may

More information

ECSS. Electric Chain Saw Chain Sharpener Assembly & Operating Instructions

ECSS. Electric Chain Saw Chain Sharpener Assembly & Operating Instructions ECSS Electric Chain Saw Chain Sharpener Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides

More information

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03 INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR469000 OR25 REV03 I II CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment

More information

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016. Symmetra PX 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V Receiving and Unpacking 01/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks

More information

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions.  Please read these instructions carefully KEYSTONE Please read these instructions carefully This symbol indicates important messages and safety instructions. Hazard potentials: disregarding of instructions improper use of product insufficiently

More information

CANARY AUDIO. Vacuum Tube Preamplifier CA-800 OWNER S MANUAL. Handcrafted in California MADE IN USA

CANARY AUDIO. Vacuum Tube Preamplifier CA-800 OWNER S MANUAL. Handcrafted in California MADE IN USA CANARY AUDIO Vacuum Tube Preamplifier Handcrafted in California CA-800 OWNER S MANUAL MADE IN USA Dear Customer: Please allow us to take this opportunity to thank you for purchasing this CANARY AUDIO product.

More information

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood HAZARD POTENTIALS disregarding of instructions improper use of product insufficiently qualified personnel Valve application to be

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

Sentry Battery Charger. Installation and Operations Manual Section 75

Sentry Battery Charger. Installation and Operations Manual Section 75 Sentry Battery Charger Installation and Operations Manual 00-02-0616 03-03-08 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our

More information

1-800-MASTERFLEX ( ) (U.S. and Canada only) 11 (847) (Outside U.S.) (847) (Local)

1-800-MASTERFLEX ( ) (U.S. and Canada only) 11 (847) (Outside U.S.) (847) (Local) OPERATING MANUAL BARNANT/PONNDORF HOSE PUMPS NOTICE D UTILISATION POMPES TUBULAIRES BARNANT/PONNDORF Hose Pump and Motor Pompe tubulaire et moteur Schlauchpumpe und Motor Bomba de manguera y motor BEDIENUNGSANLEITUNG

More information

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation

More information

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva Start UP Guide Symmetra LX Tower Rack-Mount UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety Messages SAVE

More information

www. ElectricalPartManuals. com TOSHIBA 1600EP SERIES MANUFACTURED IN THE U.S.A. OPERATION MANUAL BATTERY CABINET SYSTEM SINGLE PHASE- 8/10/14/18 kva

www. ElectricalPartManuals. com TOSHIBA 1600EP SERIES MANUFACTURED IN THE U.S.A. OPERATION MANUAL BATTERY CABINET SYSTEM SINGLE PHASE- 8/10/14/18 kva August 2003 Part# 55416-000 TOSHIBA BATTERY CABINET SYSTEM SINGLE PHASE- 8/10/14/18 kva 1600EP SERIES MANUFACTURED IN THE U.S.A. OPERATION MANUAL 1600EP SERIES SINGLE PHASE- 8/10/14/18 kva BATTERY CABINET

More information

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been

More information

Safety and General Information

Safety and General Information Safety and General Information Symmetra LX Tower Rack-Mount UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva Important Safety

More information

LOG CHOP. Hydraulic Wood Guillotine. Owners Illustrated Instruction Book & Parts List

LOG CHOP. Hydraulic Wood Guillotine. Owners Illustrated Instruction Book & Parts List LOG CHOP Hydraulic Wood Guillotine Owners Illustrated Instruction Book & Parts List Grovebury Road, Leighton Buzzard, Bedfordshire. LU7 4UX. UK. Tel:01525 375157. Fax:01525 385222. Email: enquires@brownsagricultural.co.uk

More information

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors Operating Instructions Read and observe these Operating Instructions! Diaphragm Vacuum Pumps and Compressors N022 AN.18 N022 AT.18 N022 AV.18 N026.1.2 AN.18 N026.1.2 AT.18 N026.1.2 AV.18 N026.3 AN.18 N026.3

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090529 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW Line/Load Reactors are components designed to improve the

More information

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors Operating Instructions Read and observe these Operating Instructions! Diaphragm Vacuum Pumps and Compressors N145 AN.18 N145 AT.18 N145 AV.18 N145.1.2 AN.18 N145.1.2 AT.18 N145.1.2 AV.18 KNF Neuberger

More information

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE MODEL A96 SERIES 130Vdc Switchmode Utility Rectifier / Battery Charger Used with LaMarche Power Cage CPN112138 ECN/DATE ISSUE DATE: ECN 17010-12/05 106 BRADROCK DRIVE DES PLAINES, IL. 60018-1967 (847)

More information

SMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL

SMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL SMC BATTERY CHARGER SMC 1 INDEX 1 INDEX... 1 2 INTRODUCTION... 2 2.1 INTRODUCTION AND REFERENCES... 2 2.2 GLOSSARY... 2 2.3 DATA LABEL... 2 2.4 HOW TO USE THE USER'S MANUAL... 2 2.5 RESPONSIBILITY DISCLAIMER...

More information

Lumitester PD-20 Control Kit

Lumitester PD-20 Control Kit 日本語による取扱説明は 17 ページからとなります Lumitester PD-20 Control Kit Operation manual Thank you for purchasing the Lumitester PD-20 Control Kit. To use this kit safely and correctly, read this operation manual carefully

More information

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1 T Series (N6052T) Solar Battery Hybrid System Installation Manual Version 1.1 Content 1. Safety... 1 1.1 How to Use This Manual... 1 1.2 Safety Rules... 1 1.3 Warning Notices Affixed to the Device... 2

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 6027 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Galaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/

Galaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/ Galaxy VM Installation GVMMODBCW, GVMMODBCN 09/2018 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred

More information

DC POWER SUPPLY ALIMENTATION C.C.

DC POWER SUPPLY ALIMENTATION C.C. DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify

More information

Installation Instructions Studio Makeup Station

Installation Instructions Studio Makeup Station Installation Instructions Studio Makeup Station 30" and 36" Models 5-light 30" Studio Makeup Station 8-light 30" Studio Makeup Station 6-light 36" Studio Makeup Station 9-light 36" Studio Makeup Station

More information

Max-Upender/Tilt Series Service Manual

Max-Upender/Tilt Series Service Manual Max-Upender/Tilt Series Service Manual LIFT PRODUCTS INC PO BOX 349 ELM GROVE WI 53122 262-521-5720 FAX 262-521-5725 Toll Free 877-543-8776 Model: Max-Upenders & Tilt Tables Manual No. 90185-B REVA 09/08

More information