Selection Guide. Sensitivity. High. Low. Resistance. Soy sauce Alkali Caustic soda Hydrochloric acid Sulphuric acid

Size: px
Start display at page:

Download "Selection Guide. Sensitivity. High. Low. Resistance. Soy sauce Alkali Caustic soda Hydrochloric acid Sulphuric acid"

Transcription

1 Capaci itance Level Sensor, Model CG, K series Selection Guide High Sensitivity Low Ω Resistance 2Ω Plastic Oil Butter Alumina Rice Oats Sesame Silicon oil Chocolate Oil paint Freon Lime hydrate Fly ash Sand Starch Syrup Alcohol Beer Culture fluid Whip cream Water ink Urethane Blast sand Ammonia Soy Milk Water paint Night soil Facial cream Clay Tap water Milk Slurry Pulp Water wax Mixed concrete Soy sauce Alkali Caustic soda Hydrochloric acid Sulphuric acid Milk lime Electrolyte Detergent Shampoo Rinse Bean paste Minced fish Carbon Sludge Dehydrated cake Drainage of animal Sauce Model CG KRV / KRS KSV KSV-9N & PR2100-7U 1

2 Capacitance Level Sensor, Model CG, K series Features of Model CG Easy adjustment by parameter Adjustment can be easily done by using 4 push button switches to select parameter and enter setting value. The setting error by personal difference can be avoided. Moreover, tester and tool are not required. Various functions by microprocessor Sensitivity adjustment, Delay timer, Switchover of relay output, Setting function of detection level, Self-diagnostic function are all available. Operation LCD display Can be check all operative condition on LCD by 6 digit display, status display, 8 segment bar graph display. Improvement of function for adhesion The operational principle is different with conventional principle for detecting changes in voltage (frequency). The sensor may not be affected by resistance of adhesion due to the detection of changes in capacitance value to changes in frequency. Outstanding reliability Outstanding reliability with dielectric constant as low as 1.2. Features of KRV Series Outstanding reliability Outstanding reliability with dielectric constant as low as 1.1. Easy to change the sensitivity The sensitivity can be easily changed by 5 selection sensitivity switches. Operation LED display Operation condition can easily checked by Red LED. Features of KSV Series Suitable for high adherent medium and high conductivity medium The series resonance circuit corrects for conductive build up by measuring its resistance. Easy to set the sensitivity The sensitivity can be changed by high and low sensitivity switch and sensitivity volume. 2

3 Capacitance Level Sensor, Model CG, K series Comparative Table Model CG KRV Series KSV Series Dielectric constant N/A Sensitivity Setting Parameter 5 selection switch High/Low switch Sensitivity More than 1pF A 0.5pF H 5pF B1 3pF B2 5pF C 200pF D 4000pF L 90pF Tool for adjustment Not required Tester, Screwdriver Tester Reliability Excellent High High Operability Excellent High High Variety of Model Excellent Middle Middle Range of application Wide Middle Narrow Conductive medium Depend on the application Depend on the application Recommend Heavy adherent medium Depend on the application Depend on the application Recommend Example of adhesion Sauce Ketchup Mayonnaise Shampoo Rinse Milk Recommend Model CG CG CG CG CG CG KRV KRV KRV KSV KSV KSV KSV KSV KSV KSV-9N 3

4 Capacitance Level Sensor, Model CG, K series Industrial Classification CG K Series KSV-9N Power, Gas, Municipal, Public Food, Pharmaceutical Pulp, Paper Petrochemical, Chemical Cement, Glass Steel, Non-ferrous metal Car, Ship Medical or Physical Equipment Electric or Electric Equipment Industrial Equipment Application Guide High level detection for fermentation tank There is the bubble on the surface of fermentation tank at beer factory. It is difficult to detect bubble by capacitance sensor, because the capacity of bubble is almost same with air. However, our capacitance sensor is available with detection plate at the tip of electrode for bubble detection. High and low level detection for cacao mash Although highly viscous cacao mash build up on the probe, Model CG accurately works at the calibrated position. 4

5 Capacitance Level Sensor, Model CG, K series Application Guide Additive level of blending process and Pigment level of coaster process In blending process, several additives such as aluminum sulfate, clay, talc, and calcium carbonate are pasted on the paper to prevent the ink from blotting, and to smooth the paper. Pigment (Kaolinite) is pasted on color printing papers to prevent the ink from blotting. Model CG and KSV series are ideal for heavy viscosity and build up. High level detection of acrylic resin (solids) and dissolved resin by solvent (liquid) Model CG withstands static electricity and heavy build-up. To consider chemical resistance, probe material is 316 Stainless Steel, and insulator is PTFE with FPM/FKM O-ring. Cement silo at finishing process Cement and its raw material normally contain moisture. Model CG and K series are not affected by the change of moisture and build- up. On the other hand, dry cement fed by a pneumatic conveyor holds high static electricity. Model CG and K series, however, discharge it, as the sensor has an earth terminal. 5

6 Capacitance Level Sensor, Model CG, K series Application Guide Pharmaceutical (Solid Tablet) Lubricants are used to add into mixed powders to avoid it from sticking to the hopper or to the tablet machine. Model CG and K series show stable operation although lubricants are fluidized. The pneumatic conveyor The pneumatic conveyor transmits plastic resins or powders with pneumatic pressure. Model CG and K series are suitable for high level detection in this pressurized hopper to prevent powders from sticking to the probe. It withstands static electricity by discharging to the earth. Interface detection Model CG and KRV series are ideal for the interface detection of two immiscible liquids. Interface detection between oil and water is typical application. The output relay is energized by water and de-energized by oil. 6

7 CG Series Capacitance Level Sensor (Phase Detection Principle) Products Overview We, NOHKEN INC., have plenty of experience with capacitance level sensor for more than 30 years, and we consolidate all experience into CG series. CG series employ phase detection principle which the changing of resonance frequency is processed by microprocessor (digital circuit) and the changes in capacitance value is detected by changes in frequency value. Principle of Operation The basic oscillator circuit is of the parallel resonance circuit with L (coil) and C (capacitance between the electrodes). The oscillation frequency (f) of this circuit is: f = 1/2 π LC. The frequency without material around the sensor (f1) is: f1 = 1/2 π LC, where C is the capacitance without material around the sensor (zero point). With material around the sensor, the capacitance increases (C+ΔC), and the frequency (f2) is: f2 = 1/2 π L(C+ΔC), where C+ΔC is the capacitance with material around the sensor (span point). The sensor detects the frequency change from f1 to f2, and gives a relay output. The frequency range can be divided into 8 segments (between zero and span), and the set and reset points can be set on desired segments, thus enabling high limit, low limit and hysteresis settings. With material around the sensor ZERO Set SPAN Without material around the sensor * Divide the range into 8 segments, and set ON and OFF points. Hysteresis setting is also available. Electrode rod Earth rod Insulator Electrode 7

8 Model CG Capacitance Level Sensor (Phase Detection Principle) Integral Type, CE Marking Model CG-2NK CG-2FK CG-3NK CG-3FK Description Standard Pressure Proof Mounting R3/4 (*1) JIS5K25A FF (*1) R1 (*1) JIS5K25A FF (*1) Cable Entry G1/2 Equivalent Protection Electrode IP68 IP65 Length of Electrode 250mm (4000mm Max.) 250mm (1000mm Max.) Material ADC12 (Acrylic painting) Electrode 304SS (*2) Insulator PTFE (*2) O-ring FPM/FKM (*2) Dielectric constant 1.2 Min. Sensitivity Capacitance between electrode 1.0pF Min. (But resistance between electrode 10kΩ Min. at L=250mm) 1 SPDT, 250V 3A AC, 30V 3A DC (Resistive) Relay Output C-NO: Normally open contact C-NC: Normally close contact Detection Time Delay Programmable between 0.0 to 25.5 seconds Power Supply 100 to 240V AC ±10%, 50/60Hz (24V DC in option) Power Consumption Approx. 6VA Operating Electrode -20 to 60 (without dew) Temperature -25 to 65 (without dew) Operating Pressure 1 MPa Max. 3 MPa Max. *1: The other mounting is optionally available. *2: The other material is optionally available. 85% RH Max. 8

9 Model CG Capacitance Level Sensor (Phase Detection Principle) Integral Type, CE Marking Model CG-4NK CG-4FK CG-5FK CG-6FK Description Pressure and Heat Proof Flat Type Wire Type Mounting R1 (*1) JIS5K50A FF (*1) JIS5K65A FF (*1) JIS5K50A FF (*1) Cable Entry Protection Electrode G1/2 Equivalent Length of Electrode 250mm (1000mm Max.) 65mm (1000mm Max.) 100mm (1000mm Max.) Material IP68 IP65 ADC12 (Acrylic painting) Electrode 304SS (*2) Insulator PTFE (*2) PE (*2) O-ring FPM/FKM (*2) Dielectric constant 1.2 Min. Sensitivity Capacitance between electrode 1.0pF Min. (But resistance between electrode 10kΩ Min. at L=250mm) 1 SPDT, 250V 3A AC, 30V 3A DC (Resistive) Relay Output C-NO: Normally open contact C-NC: Normally close contact Detection Time Delay Programmable between 0.0 to 25.5 seconds Power Supply Power Consumption Operating Temperature 100 to 240V AC ±10%, 50/60Hz (24V DC in option) Approx. 6VA Electrode -20 to 180 (without dew) -20 to 60 (without dew) -25 to 65 (without dew) Operating Pressure 3 MPa Max. 1 MPa Max. 500 kpa Max. *1: The other mounting is optionally available. *2: The other material is optionally available. 85% RH Max. 9

10 Model CG Capacitance Level Sensor (Phase Detection Principle) Integral Type, CE Marking Model CG-7FK CG-8FK CG-9FK CG-25FK Description Pipe Type Adhesion Proof Special Type High Sensitivity Mounting JIS5K50A FF (*1) Cable Entry Protection Electrode G1/2 Equivalent Length of Electrode 250mm (2000mm Max.) 250mm (4000mm Max.) 250mm (2000mm Max.) ADC12 (Acrylic painting) Material IP68 IP65 Electrode C3604BD 304SS (*2) Insulator FEP (Pipe) FRP PTFE (*2) PE (*2) O-ring FPM/FKM (*2) Dielectric constant 1.2 Min. Sensitivity Capacitance between electrode 1.0pF Min. (But resistance between electrode 10kΩ Min. at L=250mm) 1 SPDT, 250V 3A AC, 30V 3A DC (Resistive) Relay Output C-NO: Normally open contact C-NC: Normally close contact Detection Time Delay Programmable between 0.0 to 25.5 seconds Power Supply Power Consumption Operating Temperature Electrode 100 to 240V AC ±10%, 50/60Hz (24V DC in option) Approx. 6VA -20 to 60 (without dew) -25 to 65 (without dew) Operating Pressure 100 kpa Max. 1 MPa Max. *1: The other mounting is optionally available. *2: The other material is optionally available. 85% RH Max. 10

11 Model CGS, CG65 Capacitance Level Sensor (Phase Detection Principle) Separate Type Model Standard CGS-2N CGS-2F CGS-3N CGS-3F Intrinsically Safe CG65-2N CG65-2F CG65-3N CG65-3F Description Standard Pressure Proof Mounting R3/4 (*1) JIS5K25A FF (*1) R1 (*1) JIS5K25A FF (*1) Cable Entry Protection Electrode G1/2 Equivalent Length of Electrode 250mm (4000mm Max.) 250mm (1000mm Max.) Material Sensitivity Detection Time Delay Operating Temperature IP68 IP65 ADC12 (Acrylic painting) Electrode 304SS (*2) Insulator PTFE (*2) O-ring FPM/FKM (*2) Electrode Dielectric constant 1.2 Min. Capacitance between electrode 1.0pF Min. (But resistance between electrode 10kΩ Min. at L=250mm) Programmable between 0.0 to 25.5 seconds -20 to 60 (without dew) for standard -20 to 50 (without dew) for Intrinsically Safe -25 to 65 (without dew) for standard -20 to 50 (without dew) for Intrinsically Safe Operating Pressure 1 MPa Max. 3 MPa Max. Connecting Converter *1: The other mounting is optionally available. *2: The other material is optionally available. 85% RH Max. CGS1000 series for standard, CGS6000 series for Intrinsically Safe 11

12 Model CGS, CG65 Capacitance Level Sensor (Phase Detection Principle) Separation Type Model Standard CGS-4N CGS-4F CGS-5F CGS-6F Intrinsically Safe CG65-4N CG65-4F CG65-5F CG65-6F Description Pressure and Heat Proof Flat Type Wire Type Mounting R1 (*1) JIS5K50A FF (*1) JIS5K65A FF (*1) JIS5K50A FF (*1) Cable Entry Protection Electrode G1/2 Equivalent Length of Electrode 250mm (1000mm Max.) 65mm (1000mm Max.) 100mm (1000mm Max.) Material Sensitivity Detection Time Delay Operating Temperature IP68 IP65 ADC12 (Acrylic painting) Electrode 304SS (*2) Insulator PTFE (*2) PE (*2) O-ring FPM/FKM (*2) Electrode Dielectric constant 1.2 Min. Capacitance between electrode 1.0pF Min. (But resistance between electrode 10kΩ Min. at L=250mm) Programmable between 0.0 to 25.5 seconds -20 to 180 (without dew) for standard -20 to 60 (without dew) for standard -20 to 180 (without dew) for Intrinsically Safe -20 to 50 (without dew) for Intrinsically Safe -25 to 65 (without dew) for standard -20 to 50 (without dew) for Intrinsically Safe Operating Pressure 3 MPa Max. 1 MPa Max. 500 kpa Max. Connecting Converter *1: The other mounting is optionally available. *2: The other material is optionally available. 85% RH Max. CGS1000 series for standard, CGS6000 series for Intrinsically Safe 12

13 Model CGS, CG65 Capacitance Level Sensor (Phase Detection Principle) Separation Type Model Standard CGS-7F CGS-8F CGS-9F CGS-25F Intrinsically Safe CG65-7F CG65-8F CG65-9F CG65-25F Description Pipe Type Adhesion Proof Special Type High Sensitivity Mounting JIS5K50A FF (*1) Cable Entry Protection Electrode G1/2 Equivalent Length of Electrode 250mm (2000mm Max.) 250mm (4000mm Max.) 250mm (2000mm Max.) Material Sensitivity Detection Time Delay Operating Temperature IP68 IP65 ADC12 (Acrylic painting) Electrode C3604BD 304SS (*2) Insulator FEP (Pipe) FRP PTFE (*2) PE (*2) O-ring FPM/FKM (*2) Electrode Dielectric constant 1.2 Min. Capacitance between electrode 1.0pF Min. (But resistance between electrode 10kΩ Min. at L=250mm) Programmable between 0.0 to 25.5 seconds -20 to 60 (without dew) for standard -20 to 50 (without dew) for Intrinsically Safe -25 to 65 (without dew) for standard -20 to 50 (without dew) for Intrinsically Safe Operating Pressure 100 kpa Max. 1 MPa Max. Connecting Converter *1: The other mounting is optionally available. *2: The other material is optionally available. 85% RH Max. CGS1000 series for standard, CGS6000 series for Intrinsically Safe 13

14 Model CGS, CG65 Capacitance Level Sensor (Phase Detection Principle) Separation Type Model Standard CGS1000 CGS1010 CGS1100 CGS1110 Intrinsically Safe CGS6000 CGS6010 CGS6200 CGS6210 Description Wall Mount Rack Mount Material AC SPCC (Acrylic painting) Protection IP54 IP20 Cable Entry 3 G1/2 2 φ 15 holes Mounting 2 φ 7 holes 2 φ 4.5 holes Relay Output Operating Temperature 1 SPDT, 250V 3A AC, 30V 3A DC (Resistive) C-NO: Normally open contact C-NC: Normally close contact -20 to 60 (without dew) Power Supply V AC ±10%, 50/60Hz 24V DC V AC ±10%, 50/60Hz 24V DC Power Consumption Connecting Sensor Approx. 6VA CGS series for standard, CG65 series for Intrinsically Safe *The safety barrier must be connected between sensor and amplifier for intrinsically safe. *Z787 (PEPPERL + FUCHS) is recommended for CGS6000 and CGS6010. *CGS6200 and CGS6210 are safety barrier (Z787) built-in type. 14

15 KR Series Capacitance Level Sensor (Parallel Resonance Circuit) Products Overview The KR series of capacitance sensors are designed for point level detection of liquids, solids, powder, or interface between two immiscible liquids. The radio frequency sensors are typically used to detect liquids, but have a difficult time with solids or powder materials. The KR series overcome this limitation by having a parallel resonance circuit on its oscillator and five switch selected sensitivity ranges. The KR series easily detect solids and powder materials such as plastic powder and pellet, fly ash, carbon black, and similar substances. The KR series reliably detect the interface between two immiscible liquids, oil and water as an example. The KR series can be set to operate in water but not in oil. Principle of Operation When the electrode is in free air, the oscillation circuit synchronizes with the detection circuit. When the electrode is in the medium, the synchronization between the oscillation circuit and detection circuit breaks with the capacitance of the medium being taken in. This difference is then converted into the relay output. Sensitivity Settings for Applications "A" sensitivity: more than 0.5 pf, to 100kΩ For solids and liquids (ε S 1.1) such as Aluminum powder, Calcium carbonate, Cement, Fly ash, Ink, Paint, Plastic resin, etc. "B1" sensitivity: more than 3pF, 100kΩ to 50kΩ For solids and liquids (εs 2.2) such as Coffee powder, Feed, Flour, Oil, Starch, etc. "B2" sensitivity: more than 5pF, 50kΩ to 30kΩ For solids and liquids (εs 3.0) such as Grain, Sand, Sugar, Water, etc. "C" sensitivity: more than 200pF, 2kΩ to 200Ω For solids and liquids (εs 50) such as Dehydrated cake, Drainage, Night sol, Sewage, Slurry, etc. "D" sensitivity: more than 4000pF, 500Ω to 2Ω For liquids (εs 90) such as Chemical slurry, Quicklime (liquid), etc. Note: Normally, NOHKEN will set the proper sensitivity range before shipment in accordance with your specified medium when order. 15

16 KS Series Capacitance Level Sensor (Series Resonance Circuit) Products Overview KS series of capacitance sensors are made specifically for point level detection of conductive medium. Applications include water, chemical solutions, acid based slurries, conductive granules, and sticky liquids. Buildup is one of most common problems for capacitance sensors. The radio frequency sensor solves this problem by using a guard probes. But complicated probe construction tends to make probe easily broken. KS series overcome this limitation by using the series resonance circuit and single electrode. This circuit corrects for conductive buildup by measuring its resistance. The single electrode can be mounted in vertically and position and is available with a number of standard mounting. Principle of Operation for KS series The electrode of KS series is a part of the oscillation circuit. When the electrode is in the free air, the oscillation is stopped. When it is in medium, the oscillation is restored by measuring capacitance of medium and the relay is energized. Sensitivity Settings for Applications H Range: more than 5pF, R=more than 1.5kΩ Alcohol, Syrup, Water paint, Tap water L Range: more than 90pF, R=more than 800Ω Slurry, Pulp, Mixed concrete, Caustic soda, Sodium chloride, Dehydrated cake Ignores Heavy Conductive Buildup The characteristic of KSV circuit is defined by: 1 b>ω c: Oscillation stops (The electrode is in the air.) 2 ωb<ω c: Oscillation starts (The electrode in in the medium.) 3 ω b=1/(c+δ C) R. ωb: Frequency when the electrode is covered by medium. ωc: Adjusted frequency when the electrode is in air. C: The stray capacitance of the electrode. Δ C: The capacitance of medium. R: Resistance of medium. When a conductive resistance builds up forms on the electrode, ωb increases as R falls (3). This means ωb>ωc so that oscillation can not start (1). When actual medium level is covering the electrode, ωb decrease by taking in ΔC (3). This means ωb<ωc so that oscillation starts and the relay energizes. In this way, by taking resistance of conductive buildup and canceling capacitance of that, KSV prevents false relay trips. 16

17 KR/KS Series Capacitance Level Sensor Integral Type Model of Electrode 2NH 2FH 3NH 3FH Description Standard Pressure Proof Model of Amplifier KRV, KSV Mounting R3/4 (*1) JIS5K25A FF (*1) R1 (*1) JIS5K25A FF (*1) Cable Entry G1/2 Equivalent Protection Electrode IP68 IP65 Length of Electrode 250mm (4000mm Max.) 250mm (1000mm Max.) Material Operating Indication Relay Output Detection Time Delay Power KRV Supply KSV Power KRV Consumption KSV Operating Electrode Temperature ADC12 (Acrylic painting) Electrode 304SS (*2) Insulator PTFE (*2) O-ring FPM/FKM (*2) LED lighting (Red) 1 SPDT, 250V 3A AC, 30V 3A DC (Resistive) C-A: Normally open contact C-B: Normally close contact Adjustable between 0.5 to 10 seconds 100 to 120 / 200 to 240V AC ±10%, 50/60Hz (24V DC in option) 100V or 200V AC ±10%, 50/60Hz (24V DC in option) Approx. 2.5VA Approx. 4VA -20 to 60 (without dew) -10 to 65 (without dew) Operating Pressure 1 MPa Max. 3 MPa Max. 85% RH Max. *1: The other mounting is optionally available. *2: The other material is optionally available. 17

18 KR/KS Series Capacitance Level Sensor Integral Type Model of Electrode 4NH 4FH 5FH 6FH Description Pressure and Heat Proof Flat Type Wire Type Model of Amplifier KRV, KSV Mounting R1 (*1) JIS5K50A FF (*1) JIS5K65A FF (*1) JIS5K50A FF (*1) Cable Entry G1/2 Equivalent Protection Electrode IP68 IP65 Length of Electrode 250mm (1000mm Max.) 65mm (1000mm Max.) 100mm (1000mm Max.) ADC12 (Acrylic painting) Material Electrode 304SS (*2) Insulator PTFE (*2) PE (*2) O-ring FPM/FKM (*2) Operating indication LED lighting (Red) 1 SPDT, 250V 3A AC, 30V 3A DC (Resistive) Relay Output C-A: Normally open contact C-B: Normally close contact Detection Time Delay Adjustable between 0.5 to 10 seconds Power KRV 100 to 120 / 200 to 240V AC ±10%, 50/60Hz (24V DC in option) Supply KSV 100V or 200V AC ±10%, 50/60Hz (24V DC in option) Power KRV Approx. 2.5VA Consumption KSV Approx. 4VA Operating Electrode -20 to 180 (without dew) -20 to 60 (without dew) Temperature -10 to 55 (without dew) Operating Pressure 3 MPa Max. 1 MPa Max. 500 kpa Max. 85% RH Max. *1: The other mounting is optionally available. *2: The other material is optionally available. 18

19 KR/KS Series Capacitance Level Sensor Integral Type Model of Electrode 7FH 8FH 9FH 25FH Description Pipe Type Adhesion Proof Special Type High Sensitivity Model of Amplifier 19 KSV, KRV Mounting JIS5K50A FF (*1) Cable Entry Protection Electrode G1/2 Equivalent Length of Electrode 250mm (2000mm Max.) 250mm (4000mm Max.) 250mm (2000mm Max.) Material Operating Indication Relay Output Detection Time Delay Power Supply Power Consumption Operating Temperature IP68 IP65 ADC12 (Acrylic painting) Electrode C3604BD 304SS (*2) Insulator FEP (Pipe) FRP PTFE (*2) PE (*2) O-ring FPM/FKM (*2) KRV KSV KRV KSV Electrode LED lighting (Red) 1 SPDT, 250V 3A AC, 30V 3A DC (Resistive) C-A: Normally open contact C-B: Normally close contact Adjustable between 0.5 to 10 seconds 100 to 120 / 200 to 240V AC ±10%, 50/60Hz (24V DC in option) 100V or 200V AC ±10%, 50/60Hz (24V DC in option) Approx. 2.5VA Approx. 4VA -20 to 60 (without dew) -10 to 55 (without dew) Operating Pressure 100 kpa Max. 1 MPa Max. *1: The other mounting is optionally available. *2: The other material is optionally available. 85% RH Max.

20 KRS Series Capacitance Level Sensor Separation Type Model KRS-2N KRS-2F KRS-3N KRS-3F Description Standard Pressure Proof Mounting R3/4 (*1) JIS5K25A FF (*1) R1 (*1) JIS5K25A FF (*1) Cable Entry Protection Electrode G1/2 Equivalent Length of Electrode 250mm (4000mm Max.) 250mm (1000mm Max.) ADC12 (Acrylic painting) Material Operating Temperature IP68 IP65 Electrode 304SS (*2) Insulator PTFE (*2) O-ring FPM/FKM (*2) Electrode -20 to 60 (without dew) -10 to 55 (without dew) Operating Pressure 1 MPa Max. 3 MPa Max. Connecting Converter *1: The other mounting is optionally available. *2: The other material is optionally available. 85% RH Max. KRA, KRA-R 20

21 KRS Series Capacitance Level Sensor Separation Type Model KRS-4N KRS-4F KRS-5F KRS-6F Description Pressure and Heat Proof Flat Type Wire Type Mounting R1 (*1) JIS5K50A FF (*1) JIS5K65A FF (*1) JIS5K50A FF (*1) Cable Entry Protection Electrode G1/2 Equivalent Length of Electrode 250mm (1000mm Max.) 65mm (1000mm Max.) 100mm (1000mm Max.) Material IP68 IP65 ADC12 (Acrylic painting) Electrode 304SS (*2) Insulator PTFE (*2) PE (*2) O-ring FPM/FKM (*2) Operating Electrode -20 to 180 (without dew) -20 to 60 (without dew) Temperature -10 to 55 (without dew) Operating Pressure 3 MPa Max. 1 MPa Max. 500 kpa Max. Connecting Converter *1: The other mounting is optionally available. *2: The other material is optionally available. 85% RH Max. KRA, KRA-R 21

22 KRS Series Capacitance Level Sensor (Phase Detection Principle) Separation Type Model KRS-7F KRS-8F KRS-25F Description Pipe Type Adhesion Proof High Sensitivity Mounting JIS5K50A FF (*1) Cable Entry Protection G1/2 Equivalent Electrode IP68 Length of Electrode 250mm (2000mm Max.) 250mm (4000mm Max.) 250mm (2000mm Max.) Material Operating Temperature IP65 ADC12 (Acrylic painting) Electrode C3604BD 304SS (*2) Insulator FEP (Pipe) FRP PE (*2) O-ring FPM/FKM (*2) Electrode -20 to 60 (without dew) -25 to 65 (without dew) Operating Pressure 100 kpa Max. 1 MPa Max. Connecting Converter *1: The other mounting is optionally available. *2: The other material is optionally available. 85% RH Max. KRA, KRA-R 22

23 KRA Series Capacitance Level Sensor Separation Type Model KRA KRA-R Material ADC 12 (Silver Hammerton coating) Body: SPCC, Cover: Acrylic Protection IP54 IP10 Cable Entry 3 G1/2 φ 10 hole, φ16 hole Mounting 4 φ 6.5 holes (Pitch ) 2 φ 4.5 holes (Pitch 180) Relay Output Operating Temperature Power Supply Power Consumption 1 SPDT, 250V 3A AC, 30V 3A DC (Resistive) C-NO: Normally open contact C-NC: Normally close contact -10 to 55 (without dew) 100V or 200V AC ±10% 50/60Hz Approx. 4VA 23

24 KSV-9N Series Capacitan nce Level Sensor Compact Type Products Overview KSV-9N series are designed to use in small tank and suitable for the build-in level sensor of small or mass production devices. This sensor can detect general application of both liquids and solids. The option of plastic covered probe is available for conductive mediumm such as aqueous solution, grain and sugar contained moisture, metal powder, and so on. Features Compact and light weight, but integral construction NPN open collector can be directly connected to the relay outputt Operational indicator is provided Easy to adjust sensitivity by adjusting knob PR2100-7U is a Power Relay Unit for KSV-9N series 2-SPST relay output and self-holding control are available by using PR2100-7U Relation between dielectric constant and length of electrode 1 The length of electrode 1) Check the dielectric constant of medium by our catalog or any other document. 2) See the below and determine the length of electrodee compared with dielectric constant of medium. 3) Select correct Model number which should be matched with the length of electrode. 2 The length of Earth rod 1) Select correct Model number which 20mm of earth rod can be installed inside of tank. 24

25 KSV-9N Series Capacitan nce Level Sensor Compact Type Model KSV-9N- KSV-9N- M Mounting Protection Electrode Length of Electrode Electrode Material Insulator Earth Rod Sensitivity Stable Sensitivity Output Oscillation Frequency Power Supply Current Consumption Operating Temperature Operating Pressure R1 IP67 150mm, 300mm, 600mm 304SS Polyacetal 304SS 0 to 20pF for standard, 0 to 100pF for low sensitivity Less than 1.5pF for standard Less than 5.0pF for low sensitivity NPNN open collector Approx. 600k Hz 24V DC ±10% Approx. 21mA Max. -10 to 70 7 (without dew) 1.57 MPa Max. for electrode 35% to 95% RH Descriptio on of Model Number Standard Low Sensitivity Electrode Length of L2 Length of L1 150mm 300mm 600mm 150mm 300mm 600mm Stainlesss Steel Probe Type 20mm 100mm Model Number Model Number KSV-9N-111 KSV-9N-113 KSV-9N-121 KSV-9N-123 KSV-9N-141 KSV-9N-143 KSV-9N-111 KSV-9N-113 KSV-9N-121 KSV-9N-123 KSV-9N-141 KSV-9N-143 Plastic Covered Prove Type 20mmm 100mm Model Number Model Number KSV-9N-111M KSV-9N-113M KSV-9N-121M KSV-9N-123M KSV-9N-111M KSV-9N-113M KSV-9N-121M KSV-9N-123M 25

26 PR2100-7U Controller Model PR2100-7U Power Supply 100/110/200/220V AC ± 10% Power Consumption Approx. 4VA Max. Relay Contact 2 SPST, 200V 2A AC, 12V 10mA DC (Resistive) Output Power* 24V DC 35mA Operating Temperature -10 to 40 (without dew) 35% to 85% RH Indication Red LED for relay status Mounting 11-pin base, plug-in type (Option) *Output power is supplied to the sensor. 26

TUNING FORK LEVEL WORKING PRINCIPLE APPLICATION. Solid Level Detection FEATURE. For Liquid: * Water & Solutions * General Purpose Solvent * Petroleum

TUNING FORK LEVEL WORKING PRINCIPLE APPLICATION. Solid Level Detection FEATURE. For Liquid: * Water & Solutions * General Purpose Solvent * Petroleum TUNING FORK LEVEL WORKING PRINCIPLE The tuning fork of level switch operated by using two piezoelectric elements built-in on vibration tube. The first piezoelectric element triggered by pulse signal that

More information

Mobrey dry products level measurement and control

Mobrey dry products level measurement and control Product Data Sheet Mobrey offer a range of technologies for reliable point-level detection in a variety of dry solid applications The Mobrey Series PLS is a paddle rotating level switch that detects high

More information

Industry Product Siloheight Status Chemical ABS pellet 3m good Chemical ABS Powder, PP & PE Pellet etc good Chemical Activated carbon 3m watch out

Industry Product Siloheight Status Chemical ABS pellet 3m good Chemical ABS Powder, PP & PE Pellet etc good Chemical Activated carbon 3m watch out Industry Product Siloheight Status Chemical ABS pellet 3m good Chemical ABS Powder, PP & PE Pellet etc good Chemical Activated carbon 3m watch out Chemical Alumina dioxide 46 ft bad Chemical Ammonium sulfate

More information

PROCAP Capacitance Level Sensors

PROCAP Capacitance Level Sensors PROCAP Capacitance Level Sensors Simple. Rugged. Reliable. Triple thread screw on/off cover - No more bolts! Unsurpassed sensitivity and stability No interference from RF signals Switch selectable high/low

More information

PROCAP Capacitance Level Sensors

PROCAP Capacitance Level Sensors PROCAP Capacitance Simple. Rugged. Reliable. Triple thread screw on/off cover - No more bolts! Unsurpassed sensitivity and stability No interference from RF signals Switch selectable high/low fail-safe

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01 CAPACITIVE LEVEL SWITCHES Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01 HYCONTROL CAPACITIVE LEVEL SWITCH RANGE Hycontrol ME capacitive level switches provide simple, accurate and reliable level

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

HFS - High Frequency Limit Level Sensor

HFS - High Frequency Limit Level Sensor Ultra-modern High-Frequency limit level sensor ignores build-up or foam on the electrode and flawlessly detects tank level. Designed for reliable limit level detection of a wide range of fluids, oils,

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

CAPACITANCE LEVEL SWITCH

CAPACITANCE LEVEL SWITCH CAPACITANCE LEVEL SWITCH http: //www.fine-tek.com e-mail: info@fine-tek.com Tel: 886--696789 Fax: 886--68668 4 PRINCIPLE The capacitance level switch measuring principle is based on the "capacitance effects".

More information

Just Level. Table of Contents. Model CPH Capacitive Proximity Switch TECHNICAL INFORMATION. Principle of Operation 2. Applications 3.

Just Level. Table of Contents. Model CPH Capacitive Proximity Switch TECHNICAL INFORMATION. Principle of Operation 2. Applications 3. Table of Contents Section Page Principle of Operation 2 Applications 3 Features 7 Options / Accessories 8 Ordering Information 13 Technical Data 14 1 P a g e Principle of Operation Introduction The BlueLevel

More information

ROTARY Point Level Measurement for Inventory Control

ROTARY Point Level Measurement for Inventory Control Measure. Detect. Alert. ROTARY Point Level Measurement for Inventory Control Detect high and low levels while protecting valuable inventory with tried-and-true rotary level indicators from BinMaster. Made

More information

Screw Lift Conveyor for Efficient Elevation When Your Handling Problem Calls for Elevating Bulk Materials

Screw Lift Conveyor for Efficient Elevation When Your Handling Problem Calls for Elevating Bulk Materials Catalog No. 289B Screw Lift Conveyor for Efficient Elevation When Your Handling Problem Calls for Elevating Bulk Materials ...elevate, convey, Application Versatility and Engineering Capabilities The Screw-Lift

More information

STOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002

STOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002 STOCKTROL-H VIBRATING LEVEL SWITCH Instruction Manual June 2002 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the

More information

Contents R4 1. Capacitive Proximity Sensors

Contents R4 1. Capacitive Proximity Sensors Contents General Information Quick Selection Guide...................... page R4 2 Technical Definitions and Terminology........ page R4 3 Introduction............................... page R4 5 Products

More information

DIAMOND POINT VIBRATING PROBES

DIAMOND POINT VIBRATING PROBES DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527

More information

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids Technical Information Soliphant T FTM260 Level limit switch Cost-effective vibration limit switch for fine-grained solids Application Soliphant is a rugged level limit switch for use in silos containing

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...

More information

Model R7 Rotating Paddle Level Sensor Ideal for powders, solids, and granular material

Model R7 Rotating Paddle Level Sensor Ideal for powders, solids, and granular material NOHKEN INC Rotating Paddle Level Sensor Model R7 Rotating Paddle Level Sensor Ideal for powders, solids, and granular material Product Overview R7 is a solid level measurement sensor that is ideal to incorporate

More information

MAIN FUNCTION FEATURES. . D = v t /2

MAIN FUNCTION FEATURES. . D = v t /2 INTRODUCTION The ultrasonic level Indicator is a low-cost, noncontact and easy-to-install measurement device. It is able to meet the every-day needs of commercial production, as well serving a more specialized

More information

Level Limit Switch soliphant FTM 930/931/932/ Z

Level Limit Switch soliphant FTM 930/931/932/ Z Technical Infmation TI 042F/00/e Level Limit Switch soliphant FTM 930/931/932/ Z F Universal Application with Bulk Materials and Dust Ex Area Application The Soliphant has a wide range of safe applications

More information

MAIN FUNCTION FEATURES. . D = v t /2

MAIN FUNCTION FEATURES. . D = v t /2 ttp e-te com e-ma l o e-te com LT ASONIC LE EL MEAS EMENT Tel -2-22 Fa -2-22 2 INTRODUCTION The ultrasonic level Indicator is a low-cost, noncontact and easy-to-install measurement device. It is able to

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...

More information

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES FLOW METER P.193 P.195 P.196 P.197 P.198 P.198 P.198 P.199 P.199 P.200 P.200 P.200 P.200 ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES INSERTION

More information

P U L S A R point 210

P U L S A R point 210 P U L S A R point 210 Page 2 Fourth Edition - Version 1.0 Jan 2014 Copyright Copyright PULSAR Process Measurement Limited 2014. All rights reserved. No part of this publication may be reproduced, transmitted,

More information

Vibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS

Vibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS Vibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS VIBRATING PROBE LEVEL SWITCHES FOR LIQUIDS AND SOLIDS PRINCIPLE OF

More information

Level Devices. Rotary Level Indicators Roto-Bin-Dicator

Level Devices. Rotary Level Indicators Roto-Bin-Dicator 7901 NW 107th Terrace Level Devices We offer Rotary Level Indicators, Radio Frequency Level Indicators, and Turning Fork Level Sensors. For more information please contact your Schenck Process Aftermarket

More information

The Mobrey product range provides reliable point level detection in a variety of dry solid applications

The Mobrey product range provides reliable point level detection in a variety of dry solid applications Product Data Sheet June 2015 IP400, Rev DG Mobrey Dry Products Level Measurement and Control The Mobrey product range provides reliable point level detection in a variety of dry solid applications The

More information

Read and understand this manual for safely usage.

Read and understand this manual for safely usage. TS02-0200 INSTRUCTION MANUAL FOR VIBRATING LEVEL SENSOR MODEL:VH Read and understand this manual for safely usage. This manual describes the product of standard specification. Read the other manual for

More information

ROTARY PADDLE LEVEL SWITCHES

ROTARY PADDLE LEVEL SWITCHES Paddle switch catalogue YC-PSC01 Iss. 03 ROTARY PADDLE LEVEL SWITCES LEVEL SWITCES FOR SOLIDS YCONTROL ROTARY PADDLE LEVEL SWITC YEAR WARRANTY on the motor assembly due to unique design features:- motor

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

THE LEADER The Leader IN DRY BULK in LEVEL Dry MEASUREMENT

THE LEADER The Leader IN DRY BULK in LEVEL Dry MEASUREMENT THE LEADER The Leader IN DRY BULK in LEVEL Dry MEASUREMENT Bulk Level Measurement ORIGINAL, GENUINE Established in 1934, Bindicator has built level switches to solve the toughest bulk material handling

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

Measuring Systems for Solids

Measuring Systems for Solids Measuring Systems for Solids Mass Flow Monitoring Level Tradition Technology Innovation Continuous inline moisture measuring system for bulk materials Application and Function The moisture in solids is

More information

High-speed detection even a little liquid leak

High-speed detection even a little liquid leak 737 Leak Sensor Related Information Amplifier Built-in EX-F70 SERIES SERIES Sensor selection guide...p.11~ / P.77~ General terms and conditions...p.1 General precautions...p.986~ PHOTO PHOTO Conforming

More information

Level Sensors and Switches Guided Radar (TDR) Radar Wave Level Sensors Ultrasonic Level Sensors Rotating Paddle Level Switches Vibrating Fork Level

Level Sensors and Switches Guided Radar (TDR) Radar Wave Level Sensors Ultrasonic Level Sensors Rotating Paddle Level Switches Vibrating Fork Level Level and Switches Level Level Applications Suitable for the applications in the field of chemical plastics, pharmaceutical manufacturing, fodder, grains, cement, fertilizer, powder, fuel materials, hydraulic

More information

LABORATORY PROCESS SOFTWARE AUTOMATION. ipr-series. Process- Refractometer

LABORATORY PROCESS SOFTWARE AUTOMATION. ipr-series. Process- Refractometer LABORATORY PROCESS SOFTWARE AUTOMATION ipr-series Process- Refractometer Your eye in the pipe! Inline, immediate concentration monitoring directly within the process stream. Applications Concentration

More information

R F C a p a c i t a n c e TrueCap

R F C a p a c i t a n c e TrueCap TrueCap RF Capacitance Point Level Sensors Extensive Product Line for Bulk Solid Applications Superior Sensitivity of 0.5pF is Standard Maximum Reliability and Calibration Stability Automatic Material

More information

Smart Valve explorer Smart Valve Positioner for Rotary Valve. Model SVX100 / SVX102

Smart Valve explorer Smart Valve Positioner for Rotary Valve. Model SVX100 / SVX102 No. SS2-SVX100-0100 Smart Valve explorer Smart Valve Positioner for Rotary Valve Model SVX100 / SVX102 OVERVIEW Smart Valve explorer (SVX) models SVX100 and SVX102 are microprocessor-equipped, currentpneumatic

More information

CVR-625. Compact Vibrating Rod Instruction Manual

CVR-625. Compact Vibrating Rod Instruction Manual CVR-625 Compact Vibrating Rod Instruction Manual BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

for free flowing solids NIVOROTA ROTARY PADDLE LEVEL SWITCHES LEVEL SWITCHES

for free flowing solids NIVOROTA ROTARY PADDLE LEVEL SWITCHES LEVEL SWITCHES for free flowing solids NIVOROTA ROTARY PADDLE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES MAIN FEATURES MAIN APPLICATION AREAS Level switching of free flowing solids

More information

Rotary Paddle Bin Monitor MODEL KA & KAX

Rotary Paddle Bin Monitor MODEL KA & KAX Setting The Standard For Supplier Excellence Rotary Paddle Bin Monitor MODEL KA & KAX Hassle-Free Housing Design - No Bolts! Industry Leading Motor Shut-off Feature Economical, Versatile Point Level Bin

More information

7.09 ULTRASONIC ANALYZER

7.09 ULTRASONIC ANALYZER ETHANOL CONCENTRATION MEASUREMENT PAGE 1 OF 6 DENATURANT APPLICATION BLENDING MEASUREMENT % ALCOHOL INTRODUCTION (HOW ETHANOL IS MADE) Ethanol can be produced from a variety of biological sources that

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview. Level Measurement Pointek LS200 Standard Siemens A 20 Overview onfiguration Installation Pointek LS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable

More information

LTX RF LEVEL SENSOR. Instruction Manual

LTX RF LEVEL SENSOR. Instruction Manual LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004

More information

Operating instructions Binary level sensor LMT /00 06/2011

Operating instructions Binary level sensor LMT /00 06/2011 Operating instructions Binary level sensor LMT UK 706052/00 06/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Application area...4

More information

EX-F70 SERIES EX-F60 SERIES

EX-F70 SERIES EX-F60 SERIES 85 Leak Sensor Related Information Amplifier Built-in EX-F70 SERIES SERIES General terms and conditions... F-17 General precautions... P.105 Sensor selection guide... P.81~ Korea s S-mark... P.110 PHOTO

More information

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption MEMS Gauge Pressure Sensor 2SMPP MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Piezo Resistive element provides electrical characteristics

More information

Data Sheet Mixing / Overhead Stirrers. EUROSTAR 40 digital

Data Sheet Mixing / Overhead Stirrers. EUROSTAR 40 digital Data Sheet Mixing / Overhead Stirrers EUROSTR 40 Universal laboratory stirrer designed for simple stirring tasks for quantities up to 25 l (2O). It automatically adjusts the speed through microprocessor

More information

Soliswitch FTE30. Technical Information

Soliswitch FTE30. Technical Information Technical Information Soliswitch FTE30 Level limit switch Economical paddle limit switch with type-examination certificate to ATEX dust Ex-approval zone 20 Application The universal paddle level limit

More information

monobloc lobe pumps BE series AUT. N 810 EDIZ. 11/02

monobloc lobe pumps BE series AUT. N 810 EDIZ. 11/02 monobloc lobe pumps BE series AUT. N 810 EDIZ. 11/02 STANDARD VERSION The BE SERIES Lobe Pumps derives from the well-known B series pump since it shares several of its characteristics. The AISI 316 L stainless

More information

Optidew Vision Optical Dew-Point Meter

Optidew Vision Optical Dew-Point Meter Optidew Vision Optical Dew-Point Meter Chilled Mirror Instruments A precision hygrometer, combining drift free measurement with the flexibility of a remote sensor. Ideal for laboratory and industrial measurements,

More information

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced

More information

SA FLOW METER & FLOW SWITCH (Proximity switches are used for small flow rate)

SA FLOW METER & FLOW SWITCH (Proximity switches are used for small flow rate) SF FLOW METER & FLOW SWITCH Types: SF-M: SF-MA: Instantaneous flow indicator Instantaneous flow indicator + lower (or upper) microswitch SF-MAA: Instantaneous flow indicator + lower & upper microswitches

More information

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

NIVOCONT R VIBRATING ROD LEVEL SWITCHES For solids NIVOCONT R VIBRATING ROD LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES O U R P R O F E S S NIVOCONT R VIBRATING ROD LEVEL SWITCHES MAIN FEATURES Extension up

More information

유량계전문제조업체. Electro Magnetic FLOWMETER

유량계전문제조업체. Electro Magnetic FLOWMETER 유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged

More information

QUALITY INDUSTRIAL FLOWMETERS

QUALITY INDUSTRIAL FLOWMETERS QUALITY INDUSTRIAL FLOWMETERS COMPANY PROFILE Trimec Industries is an Australian owned ISO9001:2008 quality certified company specializing in the design and manufacture of a proprietary range of positive

More information

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.

More information

Mobrey Squitch 2 Ultrasonic Liquid Level Switch

Mobrey Squitch 2 Ultrasonic Liquid Level Switch Product Data Sheet Mobrey Squitch 2 Mobrey Squitch 2 Ultrasonic Liquid Level Switch A compact, self-contained, ultrasonic gap sensor, designed for switching in clean liquids Mounting options including

More information

Standard Target for Inductive Proximity Sensors

Standard Target for Inductive Proximity Sensors Principles of Operation for Inductive Proximity Sensors Inductive proximity sensors are designed to operate by generating an electromagnetic field and detecting the eddy current losses generated when ferrous

More information

SINGLE-ACTING ACTUATORS FOR DOUBLE-ACTING & SERIES 65 POSITIONERS PNEUMATIC & ELECTRO-PNEUMATIC. The High Performance Company

SINGLE-ACTING ACTUATORS FOR DOUBLE-ACTING & SERIES 65 POSITIONERS PNEUMATIC & ELECTRO-PNEUMATIC. The High Performance Company POSITIONERS PNEUMATIC & SERIES 65 FOR DOUBLE-ACTING & SINGLE-ACTING ACTUATORS The High Performance Company SERIES 65 FEATURES The Brayline Series 65Pneumatic and Electro-Pneumatic Positioner feature modular

More information

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH http: //www.fine-tek.com e-mail: info@fine-tek.com Tel: 886-2-22696789 Fax: 886-2-22686682 OPERATING PRINCIPLE Thermal dispersion flow switch is a precise

More information

Compact. The compact stainless steel progressing cavity pump. Progressing Cavity Pumps. Handles Fragile and Viscous products

Compact. The compact stainless steel progressing cavity pump. Progressing Cavity Pumps. Handles Fragile and Viscous products Progressing Cavity Pumps Compact The compact stainless steel progressing cavity pump > > > andles Fragile and Viscous products Versatile, easy integration Low Life Cycle Cost (LCC) Compact Series: Created

More information

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS H5 Series Metal Tube Rotameter H5 series metal tube rotameter (also called variable area flow meter) is a kind of measuring meter which the flow rate is changing along with the area and is widely used

More information

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH http: //www.fine-tek.com e-mail: info@fine-tek.com Tel: 886-2-22696789 Fax: 886-2-22686682 OPERATING PRINCIPLE Thermal dispersion flow switch is a precise

More information

OM Field-Type I/P Converter Model : KUX113 User's Manual

OM Field-Type I/P Converter Model : KUX113 User's Manual OM2-5900-1130 Field-Type I/P Converter Model : KUX113 User's Manual Copyright, Notices and Trademarks 1994-2012 Azbil Corporation All Rights Reserved. While this information is presented in good faith

More information

TopGear. Gear Pumps JOHNSON PUMP

TopGear. Gear Pumps JOHNSON PUMP TopGear Gear Pumps JOHNSON PUMP Axiom Technologies-Kolkata Ph:+91 33 32951385 admin@axiomtech.co.in TopGear When reliability is the priority Gear pumps are used in all types of manufacturing industries

More information

Table 3:List of Mandatory Omani Standards

Table 3:List of Mandatory Omani Standards 2/3/1978 6/99 1/1977 - Precast concrete blocks 2/1982 - Aggregates from natural sources for concrete 3/1977 777/1997 Cement flooring tiles and wood base materials 4/1978 - Building sands from natural sources.

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption MEMS Gauge Pressure Sensor 2SMPP MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Piezo Resistive element provides electrical characteristics

More information

EF 8 EF 9. Company name Idemitsu Nippon Oil Cosmo Oil Showa Shell Sekiyu TonenGeneral Sekiyu Japan Energy

EF 8 EF 9. Company name Idemitsu Nippon Oil Cosmo Oil Showa Shell Sekiyu TonenGeneral Sekiyu Japan Energy 2 3 4 5 6 7 8 9 Company name Idemitsu Nippon Oil Cosmo Oil Showa Shell Sekiyu TonenGeneral Sekiyu Japan Energy Turbine oil P-32 Turbine oil 32 Turbine 32 Turbine oil 32 R turbine oil 32 Turbine oil 32

More information

LINEAR AND ROTATING TYPE AUTOMATIC SELF-CLEANING LIQUID FILTERS

LINEAR AND ROTATING TYPE AUTOMATIC SELF-CLEANING LIQUID FILTERS AUTO-LINE LINEAR AND ROTATING TYPE AUTOMATIC SELF-CLEANING LIQUID FILTERS HiFlux Auto-line is designed as a compact self-cleaning filter Its robust construction makes it suitable for industrial applications

More information

VERTICAL FORM FILL SEAL MACHINES

VERTICAL FORM FILL SEAL MACHINES VERTICAL FORM FILL SEAL MACHINES AUTOMATIC PACKAGING MACHINES 2 Vertical Form, Fill and Seal machines AVM AVM vertical Form, Fill and Seal (VFFS) machines automatically form a bag from a flat roll of film,

More information

QUALITY INDUSTRIAL FLOWMETERS

QUALITY INDUSTRIAL FLOWMETERS QUALITY INDUSTRIAL FLOWMETERS COMPANY PROFILE Trimec Industries is an Australian owned ISO9001:2008 quality certified company specializing in the design and manufacture of a proprietary range of positive

More information

MEMS Gauge Pressure Sensor

MEMS Gauge Pressure Sensor MEMS Gauge Pressure Sensor MEMS Gauge Pressure Senser Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Superior electrical characteristics to capative type pressure

More information

Moyno 2000 Pumps Offer Superior Pumping Performance

Moyno 2000 Pumps Offer Superior Pumping Performance Moyno 2000 Pumps Moyno 2000 Pumps Offer Superior Pumping Performance Moyno 2000 pumps set the standard in positive displacement pumping applications. The proprietary Moyno 2000 gear-type universal joint

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter No. SS2-MVC200-0100 OVERVIEW The Multivariable Mass Flow Meter AIRcube, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide (CO 2 ) gas and air. The model MVC10A/MVC10F

More information

CleverLevel level switches. The really clever alternative to vibrating forks.

CleverLevel level switches. The really clever alternative to vibrating forks. CleverLevel level switches The really clever alternative to vibrating forks. Really clever limit level detection. A new era in point level detection begins with the CleverLevel series by Baumer maintenance-free

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

PMG MAGNETIC FLOWMETER

PMG MAGNETIC FLOWMETER PMG MAGNETIC FLOWMETER Flow Pressure Level Temperature measurement monitoring control Flow Ranges 0.015-0.5 Through 350-10600 GPM 1/2 to 12 Sizes Accuracy ±0.5% or ±0.25% of Reading Viscosity and Density

More information

FLOAT TYPE LEVEL INDICATOR

FLOAT TYPE LEVEL INDICATOR FLOAT TYPE LEVEL INDICATO Pioneer of Liquid Level Indicator, Idiot-proof A pioneer level instrument for the liquid Simple operation CAT.No.AAK-100-0509E KF-100 KFG-100 FLOAT TYPE LEVEL INDICATO KF-100KFG-100

More information

Botlek Studiegroep Basics Electro Magnetic Flowmeters

Botlek Studiegroep Basics Electro Magnetic Flowmeters Arjan Meerveld, ABB b.v. / 2 juni 2016 Botlek Studiegroep Basics Electro Magnetic Flowmeters ABB Group 8 June 2016 Slide 1 Measuring Principle of EMF Faraday s law (year 1831) Measurement electrodes Magnetic

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

Smart Electromagnetic Flowmeter Detector for Sanitary use

Smart Electromagnetic Flowmeter Detector for Sanitary use MagneW3000 PLUS Smart Electromagnetic Flowmeter Detector for Sanitary use Model MGS28U OVERVIEW The MagneW3000 PLUS Smart Electromagnetic Flowmeter for Sanitary use is a high-performance and highly-reliable

More information

ROTARY OVERFLOW FILLE

ROTARY OVERFLOW FILLE ROTARY OVERFLOW FILLE RVF SERIES ROTARY VOLUMETRIC FILLERS Key Features Touch screen control packaging includes job memory, tooling memory, and management lockout Variable speed Top Drive system keeps

More information

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability

More information

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS "" includes all sensors that detect the presence of a metallic object approaching the sensing face or near the sensing face without mechanical contact.

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide

More information

process measurement solutions The dry products level control catalogue

process measurement solutions The dry products level control catalogue process measurement solutions The dry products level control catalogue 1 Dry products level measurement and control from Solartron Mobrey The measurement and control of dry products is important in all

More information

Point level measurement Capacitance switches

Point level measurement Capacitance switches Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.

More information

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption Sensor technologies Pressure sensors Operating pressure: - - 2 bar electronic Output signal digital: 2 outputs - output IO-Link electr. connection: Plug, M2x, 4-pin 233 Certificates Measurement Display

More information

Product data sheet VAPODEST

Product data sheet VAPODEST VAPODEST all systems in comparison - standard configuration Multi Touch Sensitive Screen 7 VAP 200 VAP 300 VAP 400 VAP 450 without titrator VAP 450 with titrator Programmable addition H 3 BO 3 Programmable

More information

ABB Instrumentation. Noflote designed for control of conductive liquids. Reliable on/off liquid level control for alarms or pump control

ABB Instrumentation. Noflote designed for control of conductive liquids. Reliable on/off liquid level control for alarms or pump control DATUM Series 8 Noflote Conductivity Level System Reliable on/off liquid level control for alarms or pump control Suitable for most conductive liquids including water, sewage, dilute acids and beer Durable

More information

TWIN SCREW PUMP W.V PUMP. SILI PUMP, Your reliable one-stop supplier of marine pumps.

TWIN SCREW PUMP W.V PUMP. SILI PUMP, Your reliable one-stop supplier of marine pumps. TWIN SCREW PUMP W.V PUMP Name code: W.V---twin screw pump Z ---long shaft design ZK ---short shaft design Zi ---inter bearing design SILI PUMP, Your reliable one-stop supplier of marine pumps. Shanghai

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information