1 RESOL DeltaSol B Pro Mounting Connection Handling Fault localization Examples Pro Thanks for buying a RESOL. Read this manual carefully to get the best perfomance from this unit. B

2 Page 2/24 Contents Security devices... 2 Technichal data and function survey Installation Mounting Electrical wiring Sensor types Operation and function Adjustment switch Control parameter and indication channels Indication channles S1-S Indication channels H1 und H T-regulation Maximum store temperture Limit collector tempreture Maximum collector temperature Minimum collector tempreture System cooling Operation mode Oscillating charge Thermostat function LED blinking codes Comissioning Tips for fault localization Examples collector,1 store with heating reverse raising System with store charge by solid hot fuel boiler with heating reverse raising Solar system with 1 collector, 1 store and afterheating by solid hot fuel boiler Solar system with 1 collector and 1 store with heat exchange to existing store Solar system with 1 collector and 2 stores valve logic Solar system with 1 collector and 2 stores pump logic East-/ west-collectors, 1 store Solar system with 1 collector, 1 store and afterheating Standard solar system Impressum This mounting- and operation manual including all parts is copyrighted. Another use outside the copyright requires the approval of RESOL - Elektronische Regelungen GmbH. This especially applies for copies, translations, micro films and the storage into electronic systems. Editor: RESOL - Elektronische Regelungen GmbH Important notice: We took a lot of care over the texts and drawings of this manual and to the best of our knowledge and consent. As faults can never be excluded, please note: Your own calculations and plans under consideration of the current norms and DIN-directions should only be basis for your projects. We don t offer a guarantee for the completeness of the drawings and texts of this manual - they only represent some examples. They can only be used on own risk. No liability is assumed for incorrect, incomplete or false information and the resulting damages. Errors and technical changes excepted Safety regulations: Please read the following information carefully before installing and operating the controller. In this way damage to the solar system by wrong installation will be avoided. Please observe that the mounting is adapted to the characteristics of the building, that the local regulations are respected and is conform to the technical rules. TRD 802 TRD 402 generators of group IV DIN 1988, Part 1 8 DIN 4708, Part 3 DIN 4751, Part DIN 4753 DIN 4757, Part 1 4 DIN DIN DIN VDE 0100 VDE 0185 systems VDE 0190 DIN DIN HeizAnlV Steamboiler of group III, Equipment of steamboiler systems with hot water Technichal rules for drinking water installation Central warm water heating systems Water heating systems Water heater and systems and for drinking water Solar heating and solar thermal systems Roofing and roof sealing works Plumbers works Scaffolding works Set up of electrical operating supplies General rules for setting up overvoltage protection Main potential equalization of electrical systems Gas-, water- and sewage installation systems Electrical cable- and line systems in housings Heating system regulation

3 Page 3/24 Universal system controller for solar- and heating systems housing in outstanding design and compact dimensions, easy to install multifunctional combined display 4 sensors Pt standard relays user-friendly operation by simple handling intuitive menu mode function control basic solar systems are provided DeltaSol B Pro The controller RESOL DeltaSol B Pro is used for application in standard solar thermal systems as well as in heating and air conditioning systems and persuades by its clear operation concept. A newly developed, multi-functional display enables the user to simultaneously request two temperatures (e.g. collector and store temperature). Easy pictograms give the user clear information on function and operating status of the controller and the system. This version is equipped with 4 sensor inputs for PT1000 temperature sensors, store temperature limitation and manual mode (by menu). The central element is the 3-key-field below the display. The newly developed combined LC-display enables an intuitive and reliable controller configuration as well as a comprehensive visualisation of the system status. The following standard basic systems are provided: 1 :2 separated T-circuits 2 :2 stores with valve charge logic 3 : East/west collectors 4 : System with after heating of domestic water 5 : 2 stores with pump charge logic Technical data Housing: Plastic, PC-ABS and PMMA Protction type: IP 20 / DIN Ambient temp.: C Size: 172 x 110 x 46 mm Installation: wall mounting, mountig into patch panels is possible Display: LCD, multi-functional combined display with 8 pictograms,two 2-digit text fields and two 4-digit 7- segment displays as well as one 2- coloured luminescent diode Operation: by three pushbuttons in the front of the housing Functions: standard solar controller with adjustable values: minimummaximum temperature limitation, frost protection / cooling function, security switch-off, function control according to BAW-directions as well as solar operating hour counter. Inputs: 4 temperature sensors Pt1000 Output: 2 standard relays Power supply: V~, Hz Total power supply: 4 (2) A 250 V~ Degree of faulting: 2 Rating surge voltage: 2,5 kv Temp. for ball pressure check: 75 C Mode of functioning: Type 1.b Electrostatical discharge can cause damage of electronic components. Attention! Parts are high voltage energized.

4 Page 4/24 Examples DeltaS eltasol ol B Pro 1 collector,1 store with heating reverse raising System with store charge by solid hot fuel boiler with heating reverse raising Solar system with 1 collector, 1 store and after-heating by solid hot fuel boiler: heat exchange to existing store 1 collector, 2 stores 3-way-valve charge logic East-/ west-collectors, 1 store: Solar system with 1 collector, 1 store and after-heating 1 collector, 1 store standard solar system 1 collector, 2 stores, pump charge logic Please find detailed connection schemes for the shown systems in chapter 6. Order indication: Art.-No.: RESOL DeltaS eltasol B Pro RESOL DeltaS eltasol B Pro - full kit incl. 3 temperatur sensors Pt1000 (2 x FKP6, 1 x FRP6) Accessory Overvoltage protection It is highly recommended to connect this RESOL overvoltage protection SP1 to all collector sensors in order to avoid overvoltages (e.g. by lightning). RESOL SP1 Art.-No.:

5 Page 5/24 1. Installation Warning! 1.1 Mounting Switch-off power supply before opening the housing. operation control lamp cover housing combined LCD key field clamps base The unit must only be located internally. It is not suitable for installation in hazardous locations and should not be sited near to any electromagnetic field. The controller must additionally be equipped with an all-polar gap of at least 3 mm or with a gap according to the valid installaton regulations, e.g. LS-switches or fuses. Please pay attention to a separate laying of the cable lines and installation of ac power supply. 1. Unscrew the cross-recessed screw of the cover and remove it from the housing. 2. Mark the upper fastening point on the underground and premount the enclosed dowel and screw. 3. Hang up the housing at the upper fastening point and mark the lower fastening point on the underground (hole pitch 130 mm), afterwards put the lower dowel. 4. Fasten the housing at the underground. cable conduits with strain relief 1.2 Electrical wiring sensor clamps protector consumer clamps net clamps The power supply to the controller must only be made by an external power supply switch (last step of installation!) and the line voltage must be Volt ( Hz). Flexible lines are to be fixed at the housing by enclosed strain relief supports and screws. The controller is equipped with 2 standard relays, to which the consumers e.g. pumps, valves etc. can be connected: Relay 1 18 = conductor R1 17 = neutral conductor N 13 = ground clamp Relay 2 16 = conductor R2 15 = neutral conductor N 14 = ground clamp The temperature sensors (S1 up to S4) will be connected to the following terminals independently of the polarity: 1 / 2 = Sensor 1 (e.g. Sensor collector 1) 3 / 4 = Sensor 2 (e.g. Sensor store 1) 5 / 6 = Sensor 3 (e.g. Sensor collector 2) 7 / 8 = Sensor 4 (e.g. Sensor store 2) The power supply is effected to the clamps: 19 = neutral conductor N 20 = conductor L 12 = ground clamp

6 Page 6/24 2. Sensor types Precision-platin sensors type PT1000 (FKP and FRP) are used for DeltaS eltasol B Pro. The arrangement of the sensors is of great importance to the total efficiency of the regulator. The collector temperature should be measured in the upper part of the collector. In stores with integral heat exchanger, the sensor must be directly mounted in the upper part of the heat exchanger. When using external heat exchangers, the sensor must be fixed at the bottom of the store. For individual operation systems, our product range contains 3 different types of sensors (sensors for installation in existing immersion sleeves, flatscrew sensors or cylindrical clip-on sensors). The sensor types FK and FR have the same electrical features and are available in the same models, They only differ in the connecting cable: FK: 1,5 m weather- and temperature resistant silicone cable for temperatures between -50 C C, mostly used for collectors. FR: 2,5 m PVC cable for tempertures between -5 C C, mostly used for stores. Make sure that all electrical works are carried out according to the relevant local and IEE-regulations. The sensor cables carry low voltages and they must not run together in a cable conduit with cables carrying higher voltages than 50 Volts. When using longer cables or cable conduits, please use screened cables. The sensor cables can be lengthened up to 100 m, but the cross section must be 1,5 mm² (or 0,75 mm² up to a cable length of 50m); screened cables should be used preferably. The sensors must not be in direct contact with water, please always use immersion sleeves. Immersion sensors: in different lengths (immersion depth) available FK...60: 60 mm immersion depth, immersion sleeves of chromium-plated brass FK...150: 150 mm immersion depth, immersion sleeve of chromium-plated copper Important: The sensors must be completely pushed into the sleeve and the nut must be slightly tightenend. Cylindrical clip-on sensors: for any pipe diameter; cpl. with fastening collar; FK...21 or FR...21 Ensure good thermal contact of the sensor with the pipe work by cleaning the contact area and by applying heat conduction paste between sensor and pipe. In order to protect the sensor cable against outside temperature influences, it is recommended to insulate the pipe. FK... : collector sensor FR... : reference sensor (store sensor) Flatscrew sensors: for installation on flat surfaces FK...9 or FR...9 Ensure good thermal contact. Use conduction paste and insulate the sensors against outside temperature influences. Indication: In order to avoid overvoltage damage at the collector (e.g. by lightening), it is highly recommendend to use the overvoltage protection RESOL SP1.

7 Page 7/24 3. Operation and function 3.1 Adjustment keys The controller is only operated by pushbuttons below the display. The forward-key (1) is used for scrolling forward through the indication menu or to increase the adjustment values. The backwards-key (2) is accordingly used for the reverse function. backwards forwards The adjustment channels follow the pure indication channels in the display. In order to come to these channels, press the forward key to channel H1 or H2 for 2 sec. If an adjustment value is shown on the display, SEt is indicated. In this case you can press the key Set (3) in order to change into input mode. set (selection / adjustment mode) Select a channel by keys 1 and 2 Shortly press key 3, so that SEt flashes Adjust the value by keys 1 and 2 Shortly press key 3, so that SEt permanently appears, the adjusted value is now saved 3.2 Controller parameter / indication channnels S1 = Sensor 1 S2 = Sensor 2 S3 = Sensor 3 TT if FN 4 is activated TT = Temperature Thermostat S4 = Sensor 4 H1 = Hours of Oparation Relay 1 H2 = Hours of Oparation Relay 2 FN = FuNction 1 : 2 separated T-circuits 2 : 2 stores, 1 collector / 2 stores 3 : East/West system, 2 collectors / 1 store 4 : 1 store with thermostat function 1 collector / 1 store with thermostat function DO 1 = TemperatureDifference On Relay 1 DF 1 = TemperaturDifference OfF Relais 1 SX 1 = StorageTemperatur MaXimum Relay 1 CL 1 = CollectorTemperature Limited Relay 1 CX 1 = CollectorTemperature MaXimum Relay 1 CN 1 = CollectorTemperature MiNimum OC 1 = Option Cooling Relay 1 system cooling on/off circuit 1 DO 2 = TemperatureDifference On Relay 2 DF 2 = TemperaturDifference OfF Relay 2 SX 2 = StorageTemperatur MaXimum Relay 2 CL 2 = CollectorTemperature Limited Relay 2 CX 2 = CollectorTemperature MaXimum Relay 2 CN 2 = CollectorTemperature MiNimum Relay 2 OC 2 = Option Cooling Relay 2 system cooling on/off circuit 2 PR = Priority TS = Time Stop Oscillating stop TR = Time Run Oscillating pause TO = ThermostatTemperature On TF = ThermostatTemperature OfF MM = Mode Manual 0 : Relay 1 and 2 aus 1 : Relay 1 on, Relais 2 off 2 : Relay 1 off, Relais 2 on 3 : Relay 1 and 2 on 4 : automatic regulation PG = ProGram Program number VN=Version Number Version number Please note: The controller is equipped with a security switch-off of the store, which prevents a further loading of the store at 95 C store temperature.

8 Page 8/ Indication channels S1-S4 The indication channels S1-S4 indicate the current temperatures of the sensors S1-S4 in C. If the thermostat function is activated (FN=4), the channel TT (thermostat temperature) is indicated Indication channels H1 and H2 The indication channels H1 and H2 (if FN1 or FN3 are activated) indicate the solar operating hours of the solar pump or the solar operating hours of the consumer connected to the relays R1 and R2. The operating hours sum is stored every 6 hours, so in case of a power blackout the maximum difference would be 6 hours. This indication value can not be reset Function FN FN=1: 2 separate T-circuits For regulation of 2 independent differential-circuits with separated adjustments. FN=2: 2 stores 1 collector / 2 stores For regulation of a system with 1 collector and 2 stores by means of a 3-way-valve. The stores are charged according to the priority logic (oscillating charge). FN=3: East/west 2 collectors / 1 store For regulation of a system with east/west collectors and one store my means of 2 pumps. FN=4: 1 store and thermostat function 1 collector / 1 store with thermostat function For realization of a thermostat function e.g. for using of surplus energy or after heating function. FN=5: 2 stores 1 collector / 1 store pump logic For regulation of a system with 2 stores and 1 collector. The stores are charged by means of 2 pumps and priority logic (PR).

9 Page 9/ T-regulation (DO 1/DO 2, DF 1/DF 2) The controller controls the temperatures measured by four sensors S1, S2, S3 and S4 and compares the resulting DO:urn-on temperature temperature difference with the preadjusted switch-ontemperature difference Ton (DO). The controller switches difference adjustable values 1, K ON, if the measured temperature difference DT is higher factory setting 6.0 than or identical to the preadjusted set value in channel DO. In the display is shown and the operating control lamp DF:Turn-off temperature difference adjustable values ,5 K factory setting 4.0 K flashes green. If the adjusted switch-off-temperaturedifference Toff (DF) is underrun, the controller switches- OFF. The factory setting for switch-on temperature difference is 6 K and the switch-off temperature difference is set to 4 K. Please note: Switch-on temperature difference DO must be at least 1 K higher than the switch-off temperature difference DF Maximum store temperature (SX 1/SX 2) If the adjusted maximum temperature is exceeded, a further loading of the store is stopped so that a damaging overheating can be avoided. If the maximum store temperature is exceeded, in the display is shown and (flashing), the operating control lamp flashes red. SX 1: Maximum store temperature circuit 1 SX 2: Maximum store temperature circuit 2 adjustable values C factory setting 60 C

10 Page 10/ Limit collector temperature (CL 1/CL 2) If the adjusted collector temperature limit (CL1/2) is exceeded the solar pump (R1/R2) is deactivated in order to avoid a damaging overheating of the solar components (collector safety shutdown). The limit temperature is set to 140 C by RESOL but it can be changed within the adjustment range of C. In the display is shown CL:Collector limiting and if the maximum collector temperature is temperature exceeded, the operating control lamp flashes red. Adjustable values C, Factory setting 140 C Maximum collector temperature (CX 1/CX 2) CX:Maximum collector temperature adjustable values C Facory setting 120 C If the collector temperature exceeds the adjusted maximum collector temperature (CX1/2) in standstill of the solar circuit (maximum store temperature is reached), the solar pump (R1/R2) switches-on and cools the collectors by heat transfer via lines and the store (collector cooling function). The store temperature might increase, but only up to 95 C (safety shutdown of the store). This function guarantees a longer operating time for very hot summer days and ensures a thermal relief for the collectors and the heating medium. The maximum collector temperature is set to 120 C by RESOL, but it can be changed within the adjustment range of 100 C C. In the display is shown, and if the maximum collector temperature is exceeded, the operating control lamp flashes green Minimum collector temperature (CN 1/CN 2) CN : Minimum collector temperature adjustable values C Factory setting 10 C The minimum collector temperature is a minimum switching temperature, which must be exceeded so that the solar pump (R1/R2) is switched-on. The minimum temperature shall avoid a steady starting-up of the solar pump (or solid fuel boiler charging pumps) for low collector temperatures.the minimum temperature is set to 10 C by RESOL (= deactivated). In the display is shown and if the minimum collector temperature is exceeded, the operating control lamp flashes green. This function analogly is also usable as minimum temperature limitation for solid fuel boilers, recommended adjustment value: 60 C. Please note: The minimum collector temperature is used for adjustment of the frost protection function between -10,0... 9,9 C for minimum temperature function between 10, C.

11 Page 11/ System cooling (OC 1/OC 2) If the adjusted maximum store temperature is exceeded, the solar system switches off. If the collector temperature again increases and the adjusted maximum collector temperature (CX1/2) is reached, the solar pump is running until the limit temperature is again underrun. In doing so, the store temperature can increase (subordinated active store safety shutdown), but only up to 95 C (safety shutdown of the store). If the store temperature is higher than the maximum store temperature (SX1/2) and the collector temperature is at least 5K lower than the store temperature, the solar For deactivating the system cooling adjust the values of OC1 and OC2 to 0. system is working until the store is recooled by the collector and the pipes to the adjusted maximun store temperature (Sx1/2) Oscillating charrge (PR, TS, TR, system 2+5, FN 2 or 5) Affiliated adjustment values: Factory setting Adjustable values Priority [PR] Oscillating break time [TS] 2 min min. Oscillating charge time [TR] 15 min min. The DeltaSol B Pro priority logic: Priority: The DeltaSolB Pro priority logic: The above-mentioned options and parameters are only applied for multiple store systems (system FN=2). If prioroty 0 is adjusted, the stores which show a temperature difference to the collector, are loaded in numerical order (store 1 or store 2). In general, at that time only one store is loaded. For parallel charging you need the adjustment FN=5. If priority 1 / 2 is adjusted, a priority charge of the selected store is effected until its switch-on conditions are fulfilled. The lower-ranking store is loaded by the oscillating charge. If the priority store has reached its adjusted maximum store temperature, the lower-ranking store is loaded until its switch-on conditions are reached. Oscillating break time / oscillating charge time / collector rising temperature: The controller checks the stores regarding loading facilities (switch-on difference). If the priority store cannot be loaded, the lower-ranking store is checked. If the lower-ranking tore can be charged, this is effected by the so-called oscillating charge time (TR). After termination of the oscillating charge time (TR), the loading is stopped. The controller controls the increase in collector temperature. If it increases by the collector rising temperature ( T-col 2K, fixed software value), the expired break time is again reset to zero and the oscillating break time starts again. If the switch-on condition of the priority store is not reached, the loading of the lowerranking store is continued. If the priority switch has reached its maximum temperature, the oscillating charge is not effected.

12 Page 12/ Thermostat function (TO, TF) (System 4, FN=4) After heating use of surplus energy The thermostat function works independently from the solar operation and can e.g. be used for use of surplus energy or after-heating. Factory settings: TO = 40 C, TF = 45 C TO = TF the thermostat function is deactivated, in this case relay output R2 is activated if the maximum store temperature is exceeded TO < TF the thermostat function is used for after-heating TO > TF the thermostat function is used as use of surplus energy If the 2nd relay output is activated, in the display is shown Operation mode (MM) MM R1 R2 0 off off 1 on off 2 off on 3 on on 4 auto auto The operating mode of the controller can manually be set for control- and service works. Choose the adjustment value MM, which allows the following adjustments: MM=Mode Manual Manual mode: 0 : Control lamp flashes red/green. Relay 1 and 2 off 1 : Control lamp flashes red/green. Relay 1 on, relay 2 off 2 : Control lamp flashes red/green. Relay 1 off, relay 2 on 3 : Control lamp flashes red/green. Relay 1 and 2 on 4 : Control lamp flashes green. Automatic operation LED blinking codes constantly green: red/green flashing: red flashing: everything o.k. initialisation phase manual operation sensor defect

13 Page 13/24 4. Commisioning Ac power supply must be activated. The controller passes an initialisation phase in which the operating control lamp flashes red and green. After having finished the initialisation, the controller is in automatic operation, which is the most effective one for most of the systems with the indicated factory settings. If individual conditions require an adaptation of the parameter, please adjust the values accordingly (see 3.2). 5. Tips for fault location: Please check the following points if the controller can fuse T4A RESOL DeltaS eltasol B Pro does not work faultlessly: 1. Power supply If the operating control lamp is off, please check the power supply of the controller. The controller is protected by one can fuse T4 A, which is situated at the base/isolation plate and can be replaced by opening the cover of the housing (spare fuse is enclosed in one of the accessory bags). 2. Sensor faults If there is a malfunction due to a sensor defect, the operating control lamp flashes red and the symbol is shown on the display. An error code for the concerned sensor is shown on the display (S1,S2, S3/TT or S4). Short-circuit: Short-circuit in the sensor wire with indication of the concerned temperature sensor (S1, S2, S3/TT or S4). The error code is shown on the display. Line break: Interruption of the sensor wire with indication of the concerned temperature sensor (s, S2, S3/TT or S4). The error code is shown on the display for the concerned sensor. Clamped Pt1000-temperature sensors can be checked by a resistance-measuring device. The measured temperatures can be compared with the resistance values of the table opposite. Before opening the housing please make sure that all poles are separated from the line voltage. resitance values of Pt1000 sensors

14 Page 14/24 6. Examples 6.1 Solar system with 1 collector and 1 store with heating reverse raising S1 R1 S3 S2 S4 R2 The controller measures the temperature difference between collector sensor S1 and store sensor S2. As soon as this difference is higher or identical to the adjusted value for switch-on temperature difference (DO/1), the pump (R1) is activated and the store is loaded until the switch-off temperature difference (DF/1) or the maximum store temperature (SX/1) is reached. Independently from the solar circuit a T-reverse raising is simultaneously effected. If the switch-on temperature difference (DO/2) of the sensors S3 and S4 is exceeded a 3-way valve is activated for heating circuit support by relay output R2. Channel Factory setting Change to Remark S1 sensor temperature S Collector temperature S2 sensor temperature S Lower store temperature S3 sensor temperature S Upper store temperature S4 sensor temperature S Heating circuit reverse temperature H1 Hours of operation relay Control value H2 Hours of operation relay Control value FN 1 1 FN1 = 2 separated T circuits DO/1 6 switch-on temperature difference solar pump DF/1 4 switch-off temperature difference solar pump SX/1 60 Maximum store temperature limitation CL/1 140 Collector limitation temperature CX/1 120 Maximum collector temperature CN/1 10 Minium temperature limitation is deactivated OC/1 1 System cooling is on DO/2 6 switch-on temperature difference for 3-way-valve reverse lifting DF/2 4 switch-off temperature difference for 3-way-valve reverse lifting SX/2 60 The 3-way-valve is switched off as soon as the adjusted value is reached in the heating circuit reverse. CL/2 140 This adjustment channel has no relevance in this case CX/2 120 switch-on temperature for system cooling has no influence, as the system cooling is switched off (OC/2=0) CN/2 10 Minimum temperature limitation for the reverse lifting is deactivated OC/2 1 0 system cooling is switched off MM 4 Manual mode MM 4 = automatic operation PG/VN Program number/version number

15 Page 15/ System with store charge by solid hot fuel boiler with heating reverse raising The solid hot fuel boiler is added on by control of the pump R1, if the switch-on temperature difference (DO/1) as well as the aditionally preadjusted minimum temperature (CN/ 1) is exceeded (in order to avoid flue gas condensation). The store is only loaded up to the adjusted maximum store temperature (SX/1). At the same time a T-reverse raising is effected independently from the solid hot fuel boiler. If the switch-on temperature difference (DO/2) between the sensors S3 and S4 is exceeded, a 3-way-valve is activated for heating circuit support by relay output R2. Channel Factory setting Change to Remark S1 sensor temperature S Measuring value S2 sensor temperature S Measuring value S3 sensor temperature S Measuring value S4 sensor temperature S Measuring value H1 Hours of operation relay Control value H2 Hours of operation relay Control value FN 1 1 FN1 = 2 separated T-circuits DO/1 6 switch-on temperature difference loading pump for solid fuel boiler DF/1 4 switch-off temperature difference loading pump for solid fuel boiler SX/1 60 Maximum store temperature limitation CL/1 140 Solid fuel boiler emergency shut down temperature CX/ switch-on temperature for system cooling has no influence, as the system cooling is deactivated (OC/1 = 0) CN/ C minimum temperature to avoid condensation of flue gas OC/1 1 0 System cooling deactivated DO/2 6 Switch-on temperature difference for 3-way-valve reverse lifting DF/2 4 Switch-off temperature difference for 3-way-valve reverse lifting SX/2 60 The 3-ay-valve is switched off as soon as the adjusted value is reached in the heating circuit reverse. CL/2 140 This adjustment channel has no relevance in this case. CX/2 120 Switch-on temperature for system cooling has no influence,as the system cooling is deactivated (OC/2 = 0) CN/2 10 Minimum temperature limitation for reverse lifting is deactivated OC/2 1 0 System cooling is deactivated MM 4 Manual mode/mm 4 = automatic operation PG/VN Program number/version number

16 Page 16/ Solar system with 1 collector, 1 store and afterheating by solid hot fuel boiler: S1 R1 S4 S2 R2 S3 Necessary adjustment: Kanal FN=1 The controller compares both temperature differences between collector sensor S1 and store sensor S2 as well as between solid hot fuel boiler S3 and store sensor S4. The warmth of the collector is given to the store, if the switchon temperature difference (DO/1) is exceeded. The pump R1 remains activated until the switch-off temperature difference (DF/1) is underrun. The solid hot fuel boiler is activated by control of the pump R2, if the 2nd switch-on temperature difference (DO/2) as well as the additionnally preadjusted minimum temperature (CN/2) are exceeded (in order to avoid flue gas condensation). The store is only loaded up until the adjusted maximum store temperature (SX1/ 2). Channel Factory setting Change to Remark S1 Sensor temperature S Collector temperature S2 Sensor temperature S Lower store temperature S3 Sensor temperature S Solid fuel boiler temperature S4 Sensor temperature S Upper/middle store temperature H1 Hours of operation relay Control value H2 Hours of operation relay Control value FN 1 1 FN1 = 2 separated T-circuits DO/1 6 Switch-on temperature difference solar pump DF/1 4 Switch-off temperature difference solar pump SX/1 60 Maximum store temperature limitaion CL/1 140 Collector temperature limitation CX/1 120 Maximum collector temperature CN/1 10 Minimum temperature limitation is deactivated OC/1 1 System cooling activated DO/2 6 Switch-on temperature difference for solid fuel boiler charge pump DF/2 4 Switch-off temperature difference for solid fuel boiler charge pump SX/2 60 Maximum store temperature limitation CL/2 140 Solid fuel boiler emergency shut down temperature Switch-on temperature for system cooling has no influence, as the system cooling is deactivated (OC/2 = 0) CX/ CN/ C Minimum temperature to avoid condensation of flue gas OC/2 1 0 System cooling is deactivated MM 4 Manual mode/mm 4 = automatic operation PG/VN Program number/version number

17 Page 17/ Solar system with 1 collector and 1 store with heat exchange to existing store: S1 R1 S3 R2 S2 S4 Necessary adjustment: channel FN=1 The controller measures the temperature difference between collector sensor S1 and store sensor S2. As soon as this difference is higher or identical to the adjusted value for switch-on temperature difference (DO/1), the pump R1 is activated and the store is loaded until the switch-off temperature (DF/1) or the maximum store temperature (SX/1) is reached. At the same time a heat exchange regulation is effected inpendently on the solar circuit. If the switch-on temperature difference (DO/2) between sensor S3 and S4 is exceeded, the pump R2 is activated and the store is loaded (heat exchange between solar- and existing store). Channel Factory setting Change to Remark S1 Sensor temperature S Collector temperature S2 Sensor temperature S Lower store temperature S3 Sensor temperature S Upper store temperature S4 Sensor temperature S lower temperature of existing store H1 Hours of operation relay Control value H2 Hours of operation relay Control value FN 1 1 FN1 = 2 separated T-circuits DO/1 6 Switch-on temperature difference for solar pump DF/1 4 Switch-off temperature difference for solar pump SX/1 60 Maximum store temperature limitation CL/1 140 Collector temperature limitation CX/1 120 Maximum collector temperature CN/1 10 Minimum temperature limitation is deactivated OC/1 1 System cooling is activated DO/2 6 Switch-on temperature difference for circulation pump R2 DF/2 4 Switch-off temperature difference for circulation pump R2 SX/2 60 Maximum store temperature limitation of existing store CL/2 140 This adjustment channel has ne relevance in this case CX/2 120 Switch-on temperature for system cooling has no influence, as the system cooling is deactivated (OC/2 = 0) CN/2 10 Minimum temperature limitation is deactivated OC/2 1 0 System cooling is deactivated MM 4 Manual mode MM 4 = automatic operation PG/VN Program number/version number

18 Page 18/ Solar system with 1 collector and 2 stores: Valve logic S1 R2 R1 S2 S3 Necessary adjustment Channel FN=2 The controller compares the temperature at the temperature sensor S1 with that of S2 and S3. If the measured temperature differences are higher than the adjusted values for switch-on temperature differences (DO/1) or (DO/2), pump R1 is operated and loaded up by the valve R2 until the adjusted maximum temperature (SX/1/2) is reached. Priority must be given to one of the two stores, as no parallel loading is possible. Channel Factory setting Change to Remark S1 Sensor temperature S Collector temperature S2 Sensor temperature S Store temperature 1 S3 Sensor temperature S Store temperature 2 S4 Sensor temperature S Measuring sensor only, without operational function H1 Hours of operation relay Control value FN 1 2 FN2 = solar system with 2 stores DO/1 6 Switch-on temperature difference store 1 DF/1 4 Switch-off temperature difference store 1 SX/1 60 Maximum store temperature limitation store 1 CL/1 140 Collector temperature limitation CX/1 120 Maximum collector temperature CN/1 10 Minimum temperature limitation is deactivated OC/1 1 System cooling is activated DO/2 6 Switch-on temperature difference store 2 DF/2 4 Switch-off temperature difference store 2 SX/2 60 Maximum store temperature limitation store 2 PR 1 Priority for store 1 TS 02:00 Pendulum deceleration time TR 15:00 Pendulum charing time MM 4 Manual mode MM 4 = automatic operation PG/VN Program number/version number

19 Page 19/ Solar system with 1 collector and 2 stores: Pump logic S1 R1 S2 S3 R2 The controller compares the temperature at the temperature sensor S1 with that of S2 and S3. If the measured temperature differences are higher than the adjusted values for switch-on temperature differences (DO/1) or (DO/2), in consideration of the store priority PR the pump R1 or R2 is operated and loaded up until the adjusted maximum temperature (SX/1/2) is reached. Priority must be given to one of the two stores, as no parallel loading is possible. Necessary adjustment: Channel FN=5 Channel Factory setting Change to Remark S1 Sensor temperature S Collector temperature S2 Sensor temperature S Store temperature1 S3 Sensor temperature S Store temperature 2 S4 Sensor temperature S Measuring sensor only, without operational function H1 Hours of operation relay Control value H2 Hours of operation relay Control value FN 1 5 FN5 = Solar system with 2 stores and pump charge logic DO/1 6 Switch-on temperature difference store 1 DF/1 4 Switch-off temperature difference store 1 SX/1 60 Maximum store temperature limitation 1 CL/1 140 Collector temperature limitation CX/1 120 Maximum collector temperature CN/1 10 Minimum temperature limitation is deactivated OC/1 1 System cooling is activated DO/2 6 Switch-on temperature difference store 2 DF/2 4 Switch-off temperature difference store 2 SX/2 60 Maximum store temperature limitation store 2 PR 1 Priority for store 1 TS 02:00 Pendulum deceleration time TR 15:00 Pendulum charing time MM 4 Manual mode MM 4 = automatic operation PG/VN Program number/version number

20 Page 20/ East-/ west-collectors, 1 store: S1 S3 R1 R2 S2 Necessary adjustment: Channel FN=3 The controller compares the temperatures at both collector sensors S1 and S3 with the store temperature at sensor S2. If one of the measured temperature differences is higher than the adjusted switch-on temperature differences (DO/1) and (DO/2), the corresponding pump R1/R2 is activated and the store is loaded. Channel Factory setting Change to Remark S1 Sensor temperature S Collector temperature 1 S2 Sensor temperature S Store temperature S3 Sensor temperature S Collector temperature 2 S4 Sensor temperature S Measuring sensor only, without operational function H1 Hours of operation relay Control value H2 Hours of operation relay Control value FN 1 3 FN3 = Solar system with East/West collectors DO/1 6 Switch-on temperature difference collector 1 DF/1 4 Switch-off temperature difference collector 1 SX/1 60 Maximum store temperature limitation CL/1 140 Collector temperature limitation for collector 1 CX/1 120 Maximum collector temperature for collector 1 CN/1 10 Minimum collector temperature limitation for collector 1 is deactivated OC/1 1 System cooling for collector 1 is activated DO/2 6 Switch-on temperature difference for collector 2 DF/2 4 Switch-off temperature difference for collector 2 CL/2 140 Collector temperature limitation for collector 2 CX/2 120 Maximum collector temperature or collector 2 CN/2 10 Minimum collector temperature limitation 2 is deactivated OC/2 1 System colling for collector 2 is activated MM 4 Manual mode/mm 4 = automatic operation PG/VN Program number/version number

21 Page 21/ Solar system with 1 collector, 1 store and after-heating: S1 1 R1 S3 S2 R2 Necessary adjustment: Channel FN=4 The controller measures the temperature difference between collector sensor S1 and store sensor S2. As soon as the difference is higher or identical to the adjusted value (DO/1), the pump R1 is activated and the store is loaded. If the switch-off difference (DF/1) is underrun by that difference, the pump is switched-off. The 3rd temperature sensor S3 can be used for thermostat function. TO is set for thermostat switch-on temperature and TF switch-off temperature in the adjustment channels. Dependent on the selected adjustment, the thermostat function works in afterheating or cooling operation. Channel Factory setting Change to Remark S1 Sensor temperature S Collector temperature S2 Sensor temperature S Lower store temperature TT Sensor temperature S Upper store temperature S4 Sensor temperature S Measuring sensor only, without operational function H1 Hours of operation relay Control value FN 1 4 FN4 = Solar system with thermostat function DO/1 6 Switch-on temperature difference for solar pump DF/1 4 Switch-off temperature difference for solar pump SX/1 60 Maximum store temperature limitation CL/1 140 Collector temperature limitation CX/1 120 Maximum collector temperature CN/1 10 Minimum temperature limitation is deactivated OC/1 1 System cooling is activated TO 40.0 Thermostat switch-on temperature for domestic water after heating TF 45.0 Thermostat switch-off temperature for domestic water after heating MM 4 Manual mode MM 4 = automatic opeartion PG/VN Program number/version number

22 Page 22/ Standard solar system with 1 collector and 1 store: S1 1 R1 S2 Necessary adjustment Channel FN=4 The controller measures the temperature difference between buffer store sensor S1 and store sensor S2. As soon as this difference is higher or identical to the adjusted value (DO/1), the pump R1 is activated and the store is loaded. If the switch-off difference (DF/1) is underrun by that difference, the pump is switched-off. In this systems it is necessary to deactivate the thermostat function, by setting the adjustment channels To and TF to the same value. TO= TF (thermostat function is deactivated) Channel Factory setting Change to Remark S1 Sonsor temperature S Collector temperature S2 Sonsor temperature S Lower store temperature TT Sonsor temperature S Upper store temperature S4 Sonsor temperature S Measuring sensor only, without operational function H1 Hours of operation relay Control value FN 1 4 FN4 = Solar system with thermostat function DO/1 6 Switch-on temperature difference solar pump DF/1 4 Switch-off temperature difference solar pump SX/1 60 Maximum store temprature limitation CL/1 140 Collector temperature limitation CX/1 120 Maximum collector temperature CN/1 10 Minimum temperature limitation is deactivated OC/1 1 System cooling is activated TO TO = TF TF Thermostat function is deactivated MM 4 Manual mode MM 4 = automatic operation PG/VN Program number/version number

23 Page 23/24

24 Page 24/24 Your wholesaler: Notes Design and specifications are subject to change without notice. Illustrations may differ slightly from production models.

eltasol * * Mounting Connection Operation Examples

eltasol * * Mounting Connection Operation Examples RESOL DeltaS B Mounting Connection Operation Examples *48002780* 48002780 Thanks for buying a RESOL. Read this manual carefully to get the best performance from this unit. DeltaS B www.resol.de B Page

More information

DeltaSol B * * Mounting Connection Operation Examples

DeltaSol B * * Mounting Connection Operation Examples DeltaSol B Mounting Connection Operation Examples *49009900* 49009900 Thank you for buying this product. Read this manual carefully to get the best performance from this unit. DeltaSol B DeltaSol B Page

More information

TLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual

TLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual RESOL TLR2 Mounting Connection Handling Fault localization *48001550* 48001550 TLR2 Thanks for buying a RESOL product. Read this manual carefully to get the best perfomance from this unit. B Manual www.resol.de

More information

DeltaSol AX. RESOL DeltaSol AX * * Mounting Connection Operation Application examples. manual

DeltaSol AX. RESOL DeltaSol AX * * Mounting Connection Operation Application examples. manual RESOL DeltaSol AX Mounting Connection Operation Application examples DeltaSol AX *48000250* 48000250 Thank you for buying a RESOL product. Please read this manual carefully in order to put this controller

More information

DeltaSol BS. RESOL DeltaSol BS. Mounting Connection Handling Fault localization Examples. manual

DeltaSol BS. RESOL DeltaSol BS. Mounting Connection Handling Fault localization Examples. manual RESOL DeltaSol BS Mounting Connection Handling Fault localization Examples DeltaSol BS B manual Thanks for buying a RESOL. Read this manual carefully to get the best perfomance from this unit. www.resol.de

More information

D e lt a S o l BS * * Mounting Connection Operation Troubleshooting Examples. manual

D e lt a S o l BS * * Mounting Connection Operation Troubleshooting Examples.   manual RESOL D e lt a S o l BS Mounting Connection Operation Troubleshooting Examples *48003580* 48003580 Thank your for buying this RESOL product. Read this manual carefully to get the best perfomance from this

More information

Pro. RESOL DeltaSol BS Pro. Mounting Connection Handling Fault localization Examples

Pro. RESOL DeltaSol BS Pro. Mounting Connection Handling Fault localization Examples RESOL DeltaSol BS Pro Mounting Connection Handling Fault localization Examples Pro Thanks for buying a RESOL. Read this manual carefully to get the best perfomance from this unit. www.resol.dedeltasol

More information

DeltaSol BS. RESOL DeltaSol BS * * Mounting Connection Operation Troubleshooting Examples. manual

DeltaSol BS. RESOL DeltaSol BS * * Mounting Connection Operation Troubleshooting Examples.  manual RESOL DeltaSol BS Mounting Connection Operation Troubleshooting Examples DeltaSol BS *48003600* 48003600 Thank your for buying this RESOL product. Read this manual carefully to get the best perfomance

More information

DeltaSol BS Pro. RESOL DeltaSol BS Pro * * Mounting Connection Handling Fault localization Examples. manual

DeltaSol BS Pro. RESOL DeltaSol BS Pro * * Mounting Connection Handling Fault localization Examples. manual *48000630* 48000630 RESOL DeltaSol BS Pro Mounting Connection Handling Fault localization Examples Thanks for buying a RESOL product. Read this manual carefully to get the best perfomance from this unit.

More information

DeltaSol BS. RESOL DeltaSol BS * * Mounting Connection Handling Fault localization Examples. manual

DeltaSol BS. RESOL DeltaSol BS * * Mounting Connection Handling Fault localization Examples. manual RESOL DeltaSol BS Mounting Connection Handling Fault localization Examples DeltaSol BS *48002460* 48002460 Thanks for buying a RESOL product. Read this manual carefully to get the best perfomance from

More information

SOM 6 SI SOM 6 SI. Installation, Configuration and Troubleshooting Manual. manual

SOM 6 SI SOM 6 SI. Installation, Configuration and Troubleshooting Manual. manual Installation, Configuration and Troubleshooting Manual manual Thanks for buying this product. Read this manual carefully to get the best perfomance from this unit. Contents Imprint...2 Security devices...2

More information

DeltaSol AX * *

DeltaSol AX * * DeltaSol X Differtial temperature controller Manual for the specialised craftsman Installation Operation Functions and options Troubleshooting *48000250* 48000250 Thank you for buying this RESOL product.

More information

* * Mounting Connection Handling Fault localization Examples. manual

* * Mounting Connection Handling Fault localization Examples. manual Mounting Connection Handling Fault localization Examples *49005100* 49005100 Thanks for buying this product. Read this manual carefully to get the best perfomance from this unit. manual Contents Imprint...2

More information

D e lt a S o l C2 * * Mounting Connection Operation Troubleshooting Examples. Manual

D e lt a S o l C2 * * Mounting Connection Operation Troubleshooting Examples. Manual RESOL D e lt a S o l C2 *48002921* 48002921 Mounting Connection Operation Troubleshooting Examples Thank you for buying this RESOL product. Please read this manual carefully, to get the best performance

More information

TERMOSOL 1. Table of contents. ppa. Gerald Neuse

TERMOSOL 1. Table of contents. ppa. Gerald Neuse Safety advice Please pay attention to the following safety advice in order to avoid danger and damage to people and property. Appropriate usage This product is to be used in solar thermal systems in com

More information

CS 2.2. Mounting and instruction manual. Mounting Connection Handling Fault localization Examples. manual

CS 2.2. Mounting and instruction manual. Mounting Connection Handling Fault localization Examples. manual Mounting and instruction manual Mounting Connection Handling Fault localization Examples CS 2.2 Thanks for buying a Citrin product. Read this manual carefully to get the best perfomance from this unit.

More information

BW-HE. Roth BW-HE * * Installation Operation Commissioning. Manual

BW-HE. Roth BW-HE * * Installation Operation Commissioning. Manual Roth BW-HE Installation Operation Commissioning *49013310* 49013310 BW-HE Thank you for buying this product. Please read this manual carefully to get the best performance from this unit. Please keep this

More information

Mounting Connection Handling Fault localization Examples

Mounting Connection Handling Fault localization Examples Mounting Connection Handling Fault localization Examples Thanks for buying this product. Readthis manual carefully to get the best perfomance from this unit. ------------------------------ Contents Imprint.........

More information

ISOLAR PLUS 12V * * Mounting Connection Operation Fault diagnostics Application examples. manual

ISOLAR PLUS 12V * * Mounting Connection Operation Fault diagnostics Application examples. manual Mounting Connection Operation Fault diagstics Application examples ISOLAR PLUS 12V *49006570* 49006570 Thanks for buying this product. Read this manual carefully to get the best perfomance from this unit.

More information

WMZ RESOL WMZ * * Mounting Connection Operation. Manual

WMZ RESOL WMZ * * Mounting Connection Operation. Manual RESOL WMZ Mounting Connection Operation *48003121* 48003121 WMZ Thank you for buying this RESOL product. Read this manual carefully to get the best perfomance from this unit en Manual www.resol.com Safety

More information

BS Plus. D e lt a S o l BS Plus * * Mounting Connection Operation Troubleshooting Application examples. Manual

BS Plus. D e lt a S o l BS Plus * * Mounting Connection Operation Troubleshooting Application examples. Manual *48000550* 48000550 RESOL D e lt a S o l Mounting Connection Operation Troubleshooting Application examples BS Plus Thank you for buying this RESOL product. Read this manual carefully to get the best perfomance

More information

BS Plus. D e lt a S o l BS Plus * * Mounting Connection Operation Troubleshooting Application examples. Manual

BS Plus. D e lt a S o l BS Plus * * Mounting Connection Operation Troubleshooting Application examples. Manual *48000500* 48000500 RESOL D e lt a S o l Mounting Connection Operation Troubleshooting Application examples BS Plus Thank you for buying this RESOL product. Read this manual carefully to get the best perfomance

More information

DIEMASOL A. Solar regulator. Installation instructions. Instructions for use. Technical instructions. English 06/01/06

DIEMASOL A. Solar regulator. Installation instructions. Instructions for use. Technical instructions. English 06/01/06 DIEMASOL A Solar regulator English 06/01/06 Installation instructions Instructions for use Technical instructions Copyright All sections of these instructions for installation and use are protected by

More information

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual SBS 2000 Filling and flushing station Manual for the specialised craftsman Connection Operation Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from

More information

Solar Controller SUNGO S

Solar Controller SUNGO S OPERATING INSTRUCTIONS, Issue SW1201/ 2.01/ HW2.4 Solar Controller SUNGO S Wagner& Co Figure 1 Solar Controller SUNGO S. The benefits at a glance Large display to indicate temperature, balance values and

More information

D e lt a S o l Pool * * Mounting Connection Operation Troubleshooting. Manual

D e lt a S o l Pool * * Mounting Connection Operation Troubleshooting. Manual RESOL D e lt a S o l Pool Mounting Connection Operation Troubleshooting D e lt a S o l Pool *48004110* 48004110 Thank you for buying this RESOL product. Please read this manual carefully to get the best

More information

2009 / 2010 PRICES.

2009 / 2010 PRICES. 2009 / 2010 PRICES www.resol.com GB Welcome to RESOL RESOL factory I RESOL factory II Intelligent use of solar energy Since 1977 RESOL has been standing for intelligent solar thermal control technology.

More information

ANS 21-PV. Simple solar control unit Photovoltaik version. Operation Installation instructions. Version 11 EN. Manual version 2

ANS 21-PV. Simple solar control unit Photovoltaik version. Operation Installation instructions. Version 11 EN. Manual version 2 ANS 21-PV Version 11 EN Manual version 2 Simple solar control unit Photovoltaik version Operation Installation instructions en Table of contents Simple solar control unit... 1 Photovoltaik version... 1

More information

RESOL SBS 1000 * * Connection Operation

RESOL SBS 1000 * * Connection Operation RESOL SBS 1000 Connection Operation FlowCon SBS 1000 A www.resol.de *48003820* 48003820 Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from this

More information

DeltaSol Pool. RESOL DeltaSol Pool * * Mounting Connection Operation. Manual

DeltaSol Pool. RESOL DeltaSol Pool * * Mounting Connection Operation. Manual RESOL DeltaSol Pool Mounting Connection Operation DeltaSol Pool *48003130* 48003130 Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from this unit.

More information

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE 012945A0 040906 1 MAIN FEATURES Power supply 230V~ ±10% 50Hz Backlit alphanumeric LCD display Management of 5 output

More information

DeltaSol SLL * * Solar controller Manual for the specialised craftsman. Installation Operation Functions and options Troubleshooting

DeltaSol SLL * * Solar controller Manual for the specialised craftsman. Installation Operation Functions and options Troubleshooting DeltaSol SLL beginning with firmware version 1.05 Solar controller Manual for the specialised craftsman Installation Operation Functions and options Troubleshooting *11205585* 11205585 The Internet portal

More information

Solar Controller SUNGO S

Solar Controller SUNGO S OPERATING INSTRUCTIONS, Issue 1201/2.4 Solar Controller SUNGO S Wagner& Co Figure 1 Solar Controller SUNGO S The benefits at a glance Large illuminated display to indicate temperature, balance values and

More information

ISOLAR PLUS * * Mounting Connection Application examples Operation Troubleshooting. Manual

ISOLAR PLUS * * Mounting Connection Application examples Operation Troubleshooting. Manual Mounting Connection Application examples Operation Troubleshooting ISOLAR PLUS *49011111* 49011111 Thank you for buying this product. Read this manual carefully to get the best perfomance from this unit.

More information

ANS 21. Simple solar control unit. Operation Installation instructions. Version 10 EN. Manual version 3

ANS 21. Simple solar control unit. Operation Installation instructions. Version 10 EN. Manual version 3 ANS 21 Version 10 EN Manual version 3 Simple solar control unit Operation Installation instructions en Table of contents Safety requirements... 3 Maintenance... 3 Selection of the program and sensor type...

More information

G2515. Installation. Place of installation. Electrical installation. Permissible cable lengths. Securing the controller to the base

G2515. Installation. Place of installation. Electrical installation. Permissible cable lengths. Securing the controller to the base 74 319 726 G2515 en Installation Instructions District heating controller for 2 heating circuits and d.h.w. RVD26 Keep these instructions with the controller! Installation Place of installation In a dry

More information

DeltaSol CS/4 * * Manual for the specialised craftsman. Solar controller. Installation Operation Functions and options Troubleshooting

DeltaSol CS/4 * * Manual for the specialised craftsman. Solar controller. Installation Operation Functions and options Troubleshooting DeltaSol CS/4 Version 1.11 Solar controller Manual for the specialised craftsman Installation Operation Functions and options Troubleshooting *11204293* 11204293 Thank you for buying this RESOL product.

More information

Heat Meter Integrator

Heat Meter Integrator Heat Meter Integrator Features Simply operation Integral wall and DIN-rail mounting bracket Pulsed or M-Bus output options Measures heating or cooling and heat/cooling Specification Product Codes Temperature

More information

* * Solar Controller SUNGO US plus Versatile solar controller for DHW and space heating

* * Solar Controller SUNGO US plus Versatile solar controller for DHW and space heating INSTALLATION AND OPERATING INSTRUCTIONS Solar Controller SUNGO US plus Versatile solar controller for DHW and space heating Mounting Connection Application examples Operation Troubleshooting *49012660*

More information

D e lt a S o l BS/2. RESOL D e lt a S o l BS/2 (Version 2) * * Mounting Connection Application examples Operation Troubleshooting.

D e lt a S o l BS/2. RESOL D e lt a S o l BS/2 (Version 2) * * Mounting Connection Application examples Operation Troubleshooting. RESOL D e lt a S o l BS/2 (Version 2) Mounting Connection Application examples Operation Troubleshooting D e lt a S o l BS/2 *48005401* 48005401 Thank you for buying this RESOL product. Read this manual

More information

RVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths

RVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths en Installation Instructions District heating and d.h.w. controller 74 39 68 G25 RVD2 RVD4 Keep these instructions with the controller! Installation Place of installation In a dry room, e.g. the heat exchanger

More information

RESOL D e lt a S o l BS/4 (Version 2)

RESOL D e lt a S o l BS/4 (Version 2) RESOL D e lt a S o l BS/4 (Version 2) Mounting Connection Application examples Operation Troubleshooting D e lt D e a lt S a o S l o BS/4 l BS/4 www.resol.com en Manual *48005962* 48005962 Thank you for

More information

Operating manual UPS - System

Operating manual UPS - System Operating manual UPS - System POWERMASTER M MIL 1000VA 7Min. BAX 3330 E UPS-Division Issued 15. August 2006 JOVYATLAS JOVYATLAS Elektrische Umformtechnik GmbH Groninger Straße 29-37 D-26789 Leer/Ostfriesland

More information

DeltaSol CS/2 * * Manual for the specialised craftsman. Solar controller. Installation Operation Functions and options Troubleshooting

DeltaSol CS/2 * * Manual for the specialised craftsman. Solar controller. Installation Operation Functions and options Troubleshooting DeltaSol CS/2 Version 1.11 Solar controller Manual for the specialised craftsman Installation Operation Functions and options Troubleshooting *11204303* 11204303 Thank you for buying this RESOL product.

More information

DeltaSol MX * * System controller for complex solar and heating systems Manual for the specialised craftsman

DeltaSol MX * * System controller for complex solar and heating systems Manual for the specialised craftsman DeltaSol MX Beginning with firmware version 2.02 System controller for complex solar and heating systems Manual for the specialised craftsman Installation Operation Functions and options Troubleshooting

More information

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z Installation and operating instructions Solar charge controller MPPT 10 A / 20 A EN 1 Contents 1. About these instructions... 3 1.1 Applicability... 3 1.2 Users... 3 1.3 Description of symbols... 3 2.

More information

RVD125/109 RVD145/109

RVD125/109 RVD145/109 G2511 en Installation Instructions District heating and d.h.w. controller RVD125/109 RVD145/109 Installation without base Place of installation Compact station front or control panel front Permissible

More information

Art. no TT/S2 temperature immersion sensor with 2 m siliconee cable, 180 C

Art. no TT/S2 temperature immersion sensor with 2 m siliconee cable, 180 C Temperature sensors with PT1000 sensor elements - with guaranteed degree-accuracy according to DIN EN60751 (IEC751) - ensure precise recognition of the temperature difference and optimum use of energy.

More information

MSR01. Water heating controller with solar panel support

MSR01. Water heating controller with solar panel support MSR01 Water heating controller with solar panel support version 1.4 trading Czech Republic Czech Republic 1 Content 1. Device description...3 2. Device interface...3 2.1. Inputs...3 2.2. Low tariff...3

More information

Documentation. RM-BV4 Micro DP. Filter control

Documentation. RM-BV4 Micro DP. Filter control Documentation RM-BV4 Micro DP Filter control Contents 1 Safety instructions... 3 2 Device description... 3 3 Installation... 4 4 Installation... 5 4.1 Connection of the differential pressure measuring

More information

Ultrasonic heat meter

Ultrasonic heat meter Ultrasonic heat meter Installation and user guide Flow sensor-vmc-p Energy integrator Compact heat meter Temperature senor CONTENTS Kapitel Please read this manual prior to installation Page 3 2! T! Important

More information

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel: Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation

More information

DeltaSol CS Plus * * Manual for the specialised craftsman. Solar controller. Installation Operation Functions and options Troubleshooting

DeltaSol CS Plus * * Manual for the specialised craftsman. Solar controller. Installation Operation Functions and options Troubleshooting DeltaSol CS Plus Version 1.11 Solar controller Manual for the specialised craftsman Installation Operation Functions and options Troubleshooting *11202673* 11202673 The Internet portal for easy and secure

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

Differential Temperature Controller

Differential Temperature Controller 3 337 Synco 100 Differential emperature Controller R27 Differential temperature controller for solar storage systems. Compact design with two 2-position control output AC 24 230 V. Use Plant types: Solar

More information

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment. Datasheet Ultrasonic Flow Sensors & Integrator Technical Overview Ultrasonic flow sensors have no moving parts in the volume flow, this makes them almost wear free and noiseless. They measure the flow

More information

THERMO TECHNOLOGIES USDT 2005 Analog Differential Controller

THERMO TECHNOLOGIES USDT 2005 Analog Differential Controller Revision 3 THERMO TECHNOLOGIES USDT 2005 Analog Differential Controller Note: The information supplied in this manual is for guidance only - no part of this may be used for any agreement, whether express

More information

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide Revision 8 THERMO TECHNOLOGIES USDT 2001 Differential Controller Installation and User s Guide USDT 2001 DIFFERENTIAL CONTROLLER Installation and User s Guide Table of Contents Introduction General Information

More information

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information. Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 45W 500 1400mA flexc SC EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 25W 350 1050mA flexc SC EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter

More information

DeltaSol MX * * System controller for complex solar and heating systems Manual for the specialised craftsman

DeltaSol MX * * System controller for complex solar and heating systems Manual for the specialised craftsman DeltaSol MX Beginning with firmware version 2.01 System controller for complex solar and heating systems Manual for the specialised craftsman Installation Operation Functions and options Troubleshooting

More information

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04)

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04) INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS 300 6720613720-00.1 SD UK/IE CONTENTS Contents Contents 2 1 Safety instructions and explanation of symbols 5 1.1 General safety instructions

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

SC-Max 48V series. User Manual. Solar Charge Controller 30A

SC-Max 48V series. User Manual. Solar Charge Controller 30A SC-Max 48V series Solar Charge Controller 30A User Manual Contents 1 Description of function 2 Safety Instructions and Waiver of Liability 2.1 Safety 2.2 Liability Exclusion 3 Dimensions 4 Optional 4.1

More information

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3 Operating Instructions Pneumatic Control Valve Low Temperature Type 8026 Series GS3 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 03/2006

More information

SOLAR CHARGE CONTROLLER

SOLAR CHARGE CONTROLLER SOLAR CHARGE CONTROLLER SCE 1010 / SCE 1515 / SCE 2020 / SCE 3030 Instruction Manual Please read user manual carefully before use. 1.About this manual These operating instructions are part of the product.

More information

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7 EBL 208, Art.-No 911.430 Seite 1 / 7 Contents 1. Description 2. Safety Information 3. Operating Instructions 4. Transport, Storage, Installation 5. Electrical Installation 6. Power-Up, Shut-Down, Maintenance

More information

Local Control Network - building controls in perfection

Local Control Network - building controls in perfection 2 1 F3,15A250V 2 1 1 2 F3,15A250V Installation guide Local Control Network - building controls in perfection Sensor/actuator module for DIN-rail mounting The is a sensor/actuator module for building installation

More information

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT CATALOGUE Opto-Electronics 2018.1 ILGT 5.4 Opto-Electronics 2018.1 ILGT ILGT ILGT Opto-Electronics 2018.1 5.4 Safety light grid for power operated gates, also secure directly the wing path of vertically

More information

Your new LM controller is a state-of-the art device which was developed in accordance with the latest

Your new LM controller is a state-of-the art device which was developed in accordance with the latest CAP LM-series Solar charge controller User Manual Thank you very much for buying this CAP product. Please read the instructions carefully and thoroughly before using the products. Your new LM controller

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS MAKING MODERN LIVING POSSIBLE UniLynx Indoor Installation Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 Installation Sequence 2 Important

More information

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series Driver LC 150W 200 1050mA IND sl EXC EXCITE series Product description Constant current built-in Driver for LED, particularly suitable for industrial applications in tough environments such as cold warehouses

More information

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7 EBL 99 C, Art.-Nr. 911.413 Seite 1 / 7 Contents 1. Description 2. Safety Information 3. Operating Instructions 4. Transport, Storage, Installation 5. Electrical Installation 6. Power-Up, Shut-Down, Maintenance

More information

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number ST48-WHUV.12 PID controller Order number 935.15 Wiring diagram Product description This micro-processed controller serves for temperature control at high measuring accuracy. Beside resistance sensors and

More information

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1 Installation Instructions 810701-00 Spector compact Conductivity Transmitter System LRGT 16-1 IMPORTANT NOTES...4 SAFETY NOTES...4 Danger...4 EXPLANATORY NOTES...4 Scope of supply...4 System description...4

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Operating instructions

Operating instructions SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE Operating instructions Temperature Differential Controller inputs, 1 output These operating instructions are part of the product. Read these

More information

DeltaSol E. RESOL DeltaSol E * * Mounting Connection Operation Troubleshooting. Manual

DeltaSol E. RESOL DeltaSol E * * Mounting Connection Operation Troubleshooting. Manual RESOL DeltaSol E Mounting Connection Operation Troubleshooting DeltaSol E *48000741* 48000741 Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from

More information

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951

More information

LED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2

LED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2 LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL LED FlatPanel Gen. 2 LED Recessed Mounted FlatPanels The use of state-of-the-art LED technology in conventional office and hall illumination provides a lot of

More information

SINAMICS GM150 IGCT version

SINAMICS GM150 IGCT version /2 Overview /2 Benefits /2 Design /6 Function /8 Selection and ordering data /8 Options Technical data /14 General technical data /15 Control properties /15 Ambient conditions /16 Installation conditions

More information

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents

Installation Guide. ECL Comfort 210 / 310, application A231 / A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 4 2.1 Before you start.....................................................

More information

DeltaSol Pool * * Manual for the specialised craftsman. Installation Operation Functions and options Troubleshooting

DeltaSol Pool * * Manual for the specialised craftsman. Installation Operation Functions and options Troubleshooting DeltaSol Pool Manual for the specialised craftsman Installation Operation Functions and options Troubleshooting *48003131* 48003131 Thank you for buying this RESOL product. Please read this manual carefully

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN 05-2018 ELECTRIC DEVICE UNDER VOLTAGE! Before any action related to the power supply (cables connection, device

More information

RVD110 RVD G2381en. Installation. Commissioning

RVD110 RVD G2381en. Installation. Commissioning 4 319 2788 0 G2381en en Installation Instructions District heating and d.h.w. controller RVD110 RVD130 Installation Place of installation In a dry room, e.g. the heat exchanger room Mounting choices: -

More information

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S Product Manual ABB i-bus EIB EIB Power Supply Units SV/S 30.320.5 SV/S 30.640.5 SU/S 30.640. Intelligent Installation Systems Contents Page EIB Power Supply Units. Introduction.........................................

More information

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES TECHNICAL AND INSTALLATION DOCUMENTATION STOKVIS ENERGY SYSTEMS UNIT 34 CENTRAL PARK ESTATE 34 CENTRAL PARK ESTATE WEST

More information

zelsius Installation and operating manual All that counts EnergyMetering

zelsius Installation and operating manual All that counts EnergyMetering EnergyMetering zelsius Installation and operating manual Electronic compact heat meter M-Bus and 2 inputs/outputs optional Coaxial measuring capsule 2" q p 0.6/1.5/2.5 m³/h All that counts General information

More information

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA Installation and operating instructions Solar charge controller 10 A / 15 A / 0 A / 30 A EN 74.86 08.4 1. About this manual These operating

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been

More information

Start-up instructions

Start-up instructions E l e k t r o n i k s y s t e m e G m b H Development and production of electronical systems Eichelreuth 13 Phone: +49 8641 598360 83224 Grassau Fax: +49 8641 598364 E-Mail: info@rs-steiner.com Internet:

More information

TDC 3. Temperature Difference Controller TDC 3. Installation and operating instructions

TDC 3. Temperature Difference Controller TDC 3. Installation and operating instructions Temperature Difference Controller TDC 3 Installation and operating instructions TDC 3 Temperature-Difference-Controller Read carefully before installation, commissioning and operation Content A.1 EC declaration

More information

Emergency lighting units EM series

Emergency lighting units EM series EM power PRO EZ-3 Emergency lighting supply units Product description emergency lighting supply unit with DALI interface and automatic test function Properties Mains and emergency operation DALI interface

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer, Phocos CML-V2 Solar charge controller User Manual (English) Dear customer, Thank you very much for buying this Phocos product. Please read the instructions carefully and thoroughly before using the product.

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information