Heat Link. Plumbing, Heating, & Panels Product Catalog / Price List

Size: px
Start display at page:

Download "Heat Link. Plumbing, Heating, & Panels Product Catalog / Price List"

Transcription

1 lumbing, Heating, & anels roduct Catalog / rice List 20 - Canada Effective July, 20

2

3 lumbing, Heating, & anels roduct Catalog / rice List 20 - Canada Effective July, 20

4 Table of Contents Discounts Structure & Shipping Allowances... Terms and Conditions of Sale, Delivery and ayment... 4 Heating EX Heating Tubing with O 2 Barrier... 5 EX Heating Tubing Non Barrier... 6 TwistSeal (55 mm) Manifold Assembly Kits... 8 TwistSeal (55 mm) Manifold Modules... 9 TwistSeal Mini (40 mm) Manifold Assembly Kits... TwistSeal Mini (40 mm) Manifold Modules...2 TwistSeal Manifold Accessories... Stainless Steel Manifolds...5 Stainless Steel Manifold Accessories...7 Manifold Housings...20 EX Compression Adapters way Injection Mixing...2 -way Compact Mixing System way Mixing System way Mixing System...26 Mixing Valves & Mixing Block...27 Valves...29 Mixing Valve Motors...2 Thermostatic Heads... Actuators...4 Thermostats V AC Relay...9 StatLink Modules...40 Controls...4 Sensors...42 Wet System...44 DryAbove System...47 DryBelow System...48 Floor Heating Accessories...49 Chemicals...52 Water Testing...5 Sidestream Filter...54 Insulated EX Tubing...57 HeatSeal Accessories...59 lumbing The HeatLink otable Water System...8 urelink otable Water EX-a Tubing...8 urelink ipe-in-ipe...86 urelink Reclaim Water EX Tubing...87 EasyFit Manifold...89 EasyFit Manifold Components...90 Copper Manifolds...92 SS ress Sleeves & EX Insert Fittings...94 EX Insert Elbows...96 EX Insert Threaded Elbows...97 EX Insert FT Adapters...98 EX Insert Fixture Adapters...99 EX Insert MT Adapters EX Insert Sweat Adapters... 0 EX Insert Tees EX Insert Tees & lugs... 0 Ball Valves Other Components Accessories, Tools, and arts Accessories Tools arts... Listing by Stk# Listing by Stk#... 2 Mechanical Room in a Box (anels) Introduction...6 System anel Selection...62 TM -Way Mixing anels...6 TM -Way Mixing anels...64 HE Isolation Heat Exchanger anels...65 TWH Tankless Water Heater anels...67 CD 2-Temperature Combi DHW anels...69 SSM - Stainless Steel Manifold anels...7 TSM - TwistSeal Mini Multiport Manifold anels...74 SS - Stainless Steel Manifold ump anels...75 SST - Stainless Steel Manifold Mixing anels...76 ZM Multi-branch Zone Mixing anels...77 SM Snow Melt anels...78 S - ool/spa anels...79 Solar Heat Exchanger anel

5 Discounts Structure & Shipping Allowances lease note: this price list supersedes all previous pricelists. Our standard discount structure is as follows: - Heating & lumbing Discount H - Heating Tubing Discount - lumbing Tubing Discount For your discount please contact your local sales representative. Shipping Allowances rices and specifications are subject to change without notice. roducts shipped in multiples of quantity listed only. Standard shipping times: days from confirmed order (or less). D/C pickups: days from confirmed order (or less), scheduled with local HeatLink shipping department. Minimum order value: $00.00 Backorders: Shipped with subsequent order to stocking distributor (if no subsequent order is in place, product will be shipped freight prepaid n/c).

6 Terms and Conditions of Sale, Delivery and ayment General rovisions. (a) This agreement, performances of contract and quotations are made exclusively upon the terms and conditions set out below. Alterations or deviations from the provisions herein contained shall not be binding upon HeatLink Group Inc. unless confi rmed in writing. (b) The urchaser hereby accepts the terms and conditions herein contained in their entirety. Stipulations of terms and conditions contrary to the provision hereof according to the urchaser s business or purchasing practices, invoicing, manner of payment or custom of the trade are hereby specifi cally agreed to be inapplicable to this agreement. (c) In the event that any one or more of the provisions herein contained shall become or be deemed to be invalid, illegal or unenforceable by operation of law, the validity, legality and enforceability of the remaining provisions or any part thereof shall not in any manner be affected or impaired thereby. In place and stead of any such invalid, illegal or unenforceable provisions of any part thereof, the parties hereto shall be deemed to have agreed upon terms and conditions, which, as far as permitted by law, express the intent and purpose of the within terms and conditions. lans and Specifications 2. Drawings, specifications and technical data appended to or forming part of the agreement shall at all times remain the property of HeatLink Group Inc., with all rights reserved and shall not be provided, submitted or disclosed to third parties without the express written consent of HeatLink Group Inc. Changes, alterations, deletions or additions thereto shall not be binding upon HeatLink Group Inc. unless confi rmed in writing. rices and Quotations. (a) HeatLink Group Inc. hereby specifi cally reserves the right to change, alter, amend or revoke quotations but the same shall become binding and irrevocable only upon written acceptance by both HeatLink Group Inc. and the urchaser or upon delivery to and acceptance of goods by the urchaser. (b) rices are, save and except as otherwise agreed upon, as at HeatLink Group Inc. s location in Calgary, Alberta, Canada, exclusive of cost of packaging, crating, freight or shipping, federal, provincial or local rates, tariffs and taxes in effect on date of delivery. (c) All contract prices are guaranteed for thirty (0) days from date of contract. Cost increases 0 days after contract date, including but not limited to cost increases of materials, wages, fuel, transportation or energy charges and increases in applicable federal, provincial and local rates, tariffs or taxes shall be added to the contract price and form part thereof as if originally agreed upon. (d) Contracts for delivery of goods or performance of services without specifi c agreement as to price shall be subject to the price or prices in effect on the date of delivery of goods. Terms of ayment 4. (a) Save and except as otherwise specifically agreed upon in writing, all invoices or accounts, as the case may be, shall become due and payable in full without deduction whatsoever thirty (0) days after invoice or account date. (b) Holdbacks or deductions of any kind whatsoever without prior written authorization from HeatLink Group Inc. are expressly prohibited. (c) Discounts, if any, shall be calculated on the cost of goods as per invoice, exclusive of cost of packaging, crating, freight or shipping, federal, provincial or local rates, tariffs or taxes, where applicable, or other costs or surcharges beyond control of HeatLink Group Inc. (d) ayment will be in a form agreed to and acceptable by HeatLink Group Inc. All costs for dishonour, presentment for payment or collection shall be at the expense of the urchaser and ayor. All payments by cheque, whether certifi ed or uncertifi ed, shall be deemed as having been received on the date of acceptance for payment of the said cheque or cheques by the urchaser s or ayor s bank, trust company or fi nancial institution upon whose account the cheque has been issued. (e) ayments received shall be applied fi rstly to designated accounts, dishonour or collection; secondly, to outstanding interest charges on the oldest accounts; and, thirdly, the balance, if any, of any payment shall be applied to the most recent accounts, outstanding balance or balances. If an account is past due at the time of payment, then application of received funds will be in the order best interest to HeatLink Group Inc. (f) In the event the urchaser defaults in payment or causes a cheque, bank draft or money order to be dishonoured or stops payment thereon, or HeatLink Group Inc. shall deem the urchaser insecure, all accounts shall forthwith become due and payable notwithstanding any agreement as to credit or periodic payment. (g) Overdue accounts shall bear interest at the rate stated on the face of the invoice or (if no rate is displayed on the invoice), 2% calculated and compounded monthly. Reservation of Title and roperty 5. (a) It is hereby expressly agreed that all goods shall remain the exclusive property of HeatLink Group Inc. and title shall not pass until payment in full of all invoices or accounts rendered, including cost of goods, packaging, carting, shipping or freight charges, federal, provincial or local taxes, rates and tariffs, insurance, extras to contract, interest charges, exchange or collection expenses and other sums or charges applicable has been received pursuant to the terms and conditions herein contained. (b) Goods delivered shall not, in any event, become part of real estate and the urchaser shall at all times take or initiate all steps necessary to preserve HeatLink Group Inc. s right, title and property to such goods. (c) The urchaser shall not permit any goods sold or delivered by HeatLink Group Inc. to be pledged or encumbered without express written consent from HeatLink Group Inc. In the event of seizure by third parties, the urchaser shall forthwith disclose HeatLink Group Inc. s reservation of title, right and property to such goods and shall forthwith notify HeatLink Group Inc. of such seizure and shall assist HeatLink Group Inc. at the urchaser s cost in the preservation and enforcement of HeatLink Group Inc. s right, title and property to the said goods. (d) In the event of breach of contract by the urchaser of the terms or conditions herein contained and, in particular, default of payment of invoices as hereinbefore provided, HeatLink Group Inc. shall be entitled, without prior notice, to demand delivery up of goods sold and delivered and to seize the same wherever the same may be located at any time of day or night or to cause its agents, workmen or bailiffs to seize the same, wherever the same may be located at any time of day or night notwithstanding the goods may be in possession of a subsequent purchaser or user. (e) Seizure of goods by HeatLink Group Inc. shall not be deemed to constitute termination of contract or contractual rights and obligations as between HeatLink Group Inc. and the urchaser. Delivery of Goods 6. (a) HeatLink Group Inc. shall at all times use its best efforts to maintain the delivery dates agreed upon. The delivery date or period shall be deemed to have been maintained or complied with in all events, cases or situations where the goods to be delivered leave HeatLink Group Inc. s premises on or before such date, before the expiry of such period or the urchaser is notified before the applicable date that the goods are ready for shipment. (b) Delivery dates or periods shall be extended by reason of delays causes by labour shortages, strikes or lockouts or other circumstances beyond the reasonable control of HeatLink Group Inc. Any delay or postponement of delivery to HeatLink Group Inc. of goods and supplies by its suppliers, subcontractors or co-contractors caused by strike, lockout, labour shortage or unrest or other causes beyond the reasonable control of HeatLink Group Inc., its suppliers, subcontractors or co-contractors shall in like manner extend delivery dates and periods as if the same applied to HeatLink Group Inc. (c) In the event of delay in delivery of goods caused by the urchaser for any reason whatsoever, HeatLink Group Inc. shall be entitled to charge the cost of storage calculated at the rate of one half (/2%) percent per month upon the cost of goods, such calculation commencing one month after delivery of Notice of Readiness for shipment and continuing for each and every month or part thereof thereafter until the goods can be delivered to the urchaser. Risk of roperty 7. (a) Commencing on the date of delivery of goods for shipment or transport to the urchaser, the said goods or any part thereof shall be at the risk of the urchaser. (b) Any goods or part thereof delivered for shipment or transport to the urchaser from the factory Calgary, Alberta, or elsewhere, including goods with unessential or minor defects, shall be deemed to have been accepted by the urchaser without recourse. (c) Defi ciencies or defects in goods or part thereof shipped or the shipment of the wrong goods, or part or part thereof, shall be endorsed upon the bill of lading and shall be communicated to HeatLink Group Inc. in writing within three () business days of arrival at destination. Failing such notifi cation, the urchaser shall be deemed to have accepted the goods without recourse. Return of Goods 8. (a) All or any goods returned without prior authorization by HeatLink Group Inc. shall not be accepted. (b) If returns are authorized by HeatLink Group Inc., goods will be accepted as follows: (i) New and unused goods upon authorization by HeatLink Group Inc., with freight to be prepaid plus 25% restocking charge. (ii) Outdated goods, with freight prepaid plus 25% restocking charge plus refurbishing costs. (c) In all cases, unless express written authorization is given, goods must be returned in condition for immediate resale. If goods and packaging are not in condition for immediate resale, HeatLink Group Inc. reserves the right to refuse to accept the returned goods, charge additionally for refurbishing goods or packaging, or any other agreed to return remedy negotiated with the customer. In all cases, HeatLink Group Inc. will have the fi nal approval as to whether returned goods are accepted or unaccepted under any of the above remedies. Insurance 9. During the period commencing with the delivery of goods for shipment or transport to the urchaser and ending upon receipt of payment in full for the said goods pursuant to the terms and conditions hereof, the urchaser shall insure the said goods in the joint names of HeatLink Group Inc. and the urchaser against all risk of loss or damage howsoever caused. Applicable Law 0. All disputes, claims or demands arising from or relating to warranties, guarantees, representations authorized and published by HeatLink Group Inc., and from the terms and conditions herein contained and all claims, demands, rights or liabilities arising from such warranties, guarantees, representations or terms and conditions shall be determined in accordance with the laws of the rovince of Alberta, Canada. 4

7 EX Heating Tubing with O 2 Barrier EX Tubing with O 2 Barrier Series High molecular cross-linked poly eth yl ene (EX) with minimum bend ing radii of 6 the diameter at 68 F (20 C). Maximum op er at ing tem per a ture: SI ( ka). Covered by a twen ty-five year manufacturers limited warranty. Comes with oxygen diffu sion barrier which pre vents ox y gen from entering the heat ing system through the tubing wall. - 4" ID (40.7mm) to 4" ID (0 0.0mm) EX-a Tubing is subject to extended lead times. Stk# Description kg Qty Carton Skid Qty Unit Disc. List rice / Unit 942 8" 00ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 40 coil H " 250ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 40 coil H " 00ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 40 coil H " 500ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 24 coil H " 000ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 6 coil H " 225ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 24 coil H " 450ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 6 coil H " 500ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 6 coil H " 000ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 2 coil H " 00ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 6 coil H " 500ft O 2 barrier HeatLink UV Stabilized EX-a Tubing 2 coil H " 000ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 5 coil H 9428 " 00ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 2 coil H " 500ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 5 coil H mm.7 (- 4") 50ft HeatLink O 2 Barrier EX-a Tubing coil H mm.7 (- 4") 00ft HeatLink O 2 Barrier EX-a Tubing coil H mm 4.5 (- 2") 50ft HeatLink O 2 Barrier EX-a Tubing coil H mm 4.5 (- 2") 00ft HeatLink O 2 Barrier EX-a Tubing coil H mm 5.7 (2") 50ft HeatLink O 2 Barrier EX-a Tubing coil H 946 6mm 5.7 (2") 00ft HeatLink O 2 Barrier EX-a Tubing coil H Radiant Heating & Cooling Stk# Description kg Qty Master Carton Bag Qty Unit Disc. List rice / Unit " 0 20ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 20 bundle H " 5 20ft O 2 Barrier HeatLink UV Stabilized EX-a Tubing 20 bundle H 5

8 EX Heating Tubing Non Barrier Radiant Heating & Cooling Special Order 9922 Special Order 9992 Special Order 9949 Special Order 999 EX Tubing Non Barrier & Series High molecular cross-linked poly eth yl ene (EX) with minimum bend ing radii of 6 the diameter at 68 F (20 C). Maximum operating tem per a ture: SI ( ka). Covered by a twen ty-five year manufacturers limited warranty. Stk# Description kg Qty Carton Skid Qty Unit Disc. List rice / Unit " 200ft HeatLink natural UV Stabilized EX-a Tubing 8" 000ft HeatLink natural UV Stabilized EX Tubing 5 8" 450ft HeatLink natural UV Stabilized EX-a Tubing 5 8" 000ft HeatLink natural UV Stabilized EX-a Tubing 2" 00ft urelink LUS Blue UV Stabilized EX-a Tubing 2" 500ft urelink LUS Blue UV Stabilized EX-a Tubing 2" 000ft urelink LUS Blue UV Stabilized EX-a Tubing 4" 00ft urelink LUS Blue UV Stabilized EX-a Tubing 4" 500ft urelink LUS Blue UV Stabilized EX-a Tubing 4" 000ft urelink LUS Blue UV Stabilized EX-a Tubing " 00ft urelink LUS Blue UV Stabilized EX-a Tubing " 00ft urelink LUS Blue UV Stabilized EX-a Tubing coil coil 6 coil 2 coil 2 coil 24 coil 4 coil 4 coil 9 coil 5 coil 2 coil 9 coil 6

9 TwistSeal (55 mm) Manifolds Features & Benefits : Modular tool-less assembly. Multiple configurations from basic to deluxe (all interchangeable; can be reconfigured on-site). Unlike a fixed loop manifold, loops can be added or removed as required. Stock is flexible, as there is no need to stock fixed-length manifolds. Minimal SKUs on the shelf. Balancing return. Zone valve supply with manual shut-off; accepts optional actuators. 8", 2", 5 8", and 4" tubing to manifold connectors available. Test rated to over F water temperature. 5 year limited warranty. L to R 2" & 4" EX insert tubing to manifold connectors (79400 assembly kit shown with module pairs and 2 actuators) Typical Applications: Commercial. Snow melting. L to R 8", 2", 5 8", & 4" tubing to manifold connectors (79402 assembly kit shown with module pairs and 2 actuators) Assembly Kit or 7940 or # of loops Choose Module Type Additional Recommended Housing* Brackets Balancing Recessed Surface Mount n/a n/a n/a n/a Actuator Selection Actuator with LED Actuator with End Swtich DDC Actuator (grey ring) Tubing Size Tubing to Manifold Connectors / Loop Conduit Elbows / Loop for Wet Installation Compression EX Insert 8" 7702 n/a " " 7709 n/a " *recommended housing based on kit and 90 mains piping

10 TwistSeal (55 mm) Manifold Assembly Kits Radiant Heating & Cooling TwistSeal (55 mm) Deluxe Manifold Assembly Kit Stk# This package contains the items need ed to assemble a Deluxe TwistSeal Manifold. Contents include: 2 mounting brackets 2 - " FT supply end connections 2 closed end caps lube bottle 2 cross tees c/w - 2" cross tee plugs thermometer pair c/w wells manual air vent with key au to mat ic air vent hose bib wrench for plastic nut " TwistSeal (55 mm) Deluxe Manifold Assembly Kit 20 ea. TwistSeal (55 mm) Basic Manifold Assembly Kit Stk# 7940 This package contains the items need ed to assemble a TwistSeal Manifold. Contents include: 2 mounting brackets 2 - " FT supply end connections 2 closed end caps lube bottle Wrench (#79922) sold separately " TwistSeal (55 mm) Basic Manifold Assembly Kit 20 ea. TwistSeal (55 mm) Commercial Manifold Assembly Kit Stk# This package contains the items need ed to assemble a Com mer cial TwistSeal Manifold. Contents include: 2 mounting brackets " MT supply end connections 2 closed end caps lube bottle 2 cross tees c/w - 2" cross tee plugs thermometer pair c/w wells manual air vent with key au to mat ic air vent hose bib wrench for plastic nut " TwistSeal (55 mm) Commercial Manifold Assembly Kit 20 ea. 8

11 TwistSeal (55 mm) Manifold Modules Mounting Bracket (55 mm) Stk# 7999 lastic mounting bracket which al lows easy snap-on mount ing of manifolds TwistSeal (55 mm) Mounting Bracket ea. TwistSeal Deluxe (55 mm) Supply / Return Modules c/w Heavy Duty Zone Valve Supply & Balancing Return Stk# Radiant Heating & Cooling The supply module provides on/off manual control to allow iso la tion of individual loops, and may be fitted for electric actuator and ther mo stat op er a tion. The return mod ule permits the bal anc ing of the flow rate. Comes with o-rings. Modules can be locked in place with a couple of turns. No threaded rod, solder, or tools required. Just twist and seal TwistSeal Deluxe (55mm) Heavy Duty Zone Valve Supply & Balancing Return Module air 0 pair 9

12 TwistSeal Mini (40mm) Manifolds Features & Benefits : Modular tool-less assembly. Multiple configurations from basic to deluxe (all interchangeable; can be reconfigured on-site). Unlike a fixed loop manifold, loops can be added or removed as required. Stock is flexible, as there is no need to stock fixed-length manifolds. Minimal SKUs on the shelf. 8", 2", 5 8", and 4" tubing to manifold connectors available. Test rated to over F water temperature. 5 year limited warranty. Typical Applications: Residential. Small commercial. L to R 2" & 4" EX insert tubing to manifold connectors (79200 assembly kit shown with 7822 and 782 module pairs and 2 actuators) 782x Module Specific Features: Lockable balancing return. Zone valve supply with manual shut-off; accepts optional actuators. L to R 8", 2", 5 8", & 4" tubing to manifold connectors (79200 assembly kit shown with 7802 and 780 module pairs and 2 actuators) 780x Module Specific Features: Lockable balancing return with US gpm ( L/min) flow meter. Zone valve supply with manual shut-off; accepts optional actuators. Assembly Kit # of loops Balancing Choose Module Type Multiport Balancing Multiport Flow Meter Additional Brackets Recommended Housing Recessed Surface Mount n/a Actuator Selection Actuator with LED Actuator with End Swtich DDC Actuator (grey ring) n/a n/a Tubing Size Tubing to Manifold Connectors / Loop Compression EX Insert Conduit Elbows / Loop for Wet Installation 8" 7702 n/a " " 7709 n/a " *recommended housing based on kit and 90 mains piping

13 TwistSeal Mini (40 mm) Manifold Assembly Kits TwistSeal Mini (40 mm) Deluxe Manifold Assembly Kit Stk# This package contains the items needed to assemble a mini deluxe heating manifold. Contents include: 2 mounting brackets 2 - " union cross tee end connection c/w gasket 2 - " MBS x " FT adapter 2 red rubber gaskets for air testing 2 closed end caps - 2" cross tee plug thermometer pair automatic air vent (may not be exactly as shown) manual air vent with key hose bib (may not be exactly as shown) lube bottle Radiant Heating & Cooling " TwistSeal Mini (40 mm) Deluxe Manifold Assembly Kit 20 ea. Mini Mounting Bracket (40 mm) Stk# lastic mounting bracket which allow easy snap-on mounting of manifolds. Offset provides tubing passage behind 2 nd manifold TwistSeal Multiport (40mm) Double Mounting Bracket ea.

14 TwistSeal Mini (40 mm) Manifold Modules Radiant Heating & Cooling TwistSeal Mini Deluxe (40 mm) Supply / Return Modules c/w Heavy Duty Zone Valve Supply & Balancing Return Stk# The supply module provides on/off manual control to allow isolation of individual loops. The return module permits balancing of the flow rate with flow setting dial. Comes with o-rings TwistSeal Mini Deluxe (40 mm) Z.V. Supply & Balancing Return Module air 0 pair TwistSeal Mini (40 mm) Multiport Zone Valve Supply & Flow Meter Balancing Return Module air 7800 Series The supply module provides on/off manual control to allow isolation of individual loops. The return module permits visual balancing of the flow rate with the flow meter. O-rings are included TwistSeal Mini (40 mm) 2-port Multiport Zone Valve Supply & Flow Meter Balancing 6 pair Return Module air 780 TwistSeal Mini (40 mm) -port Multiport Zone Valve Supply & Flow Meter Balancing Return Module air 4 pair TwistSeal Mini (40 mm) Multiport Zone Valve Supply & Balancing Return Module air 7820 Series The supply module provides on/off manual control to allow isolation of individual loops. The return module permits balancing of the flow rate. O-rings are included. TwistSeal Mini (40 mm) 2-port Multiport New! 7822 Zone Valve Supply & Flow Balancing Return 6 pair Module air New! 782 TwistSeal Mini (40 mm) -port Multiport Zone Valve Supply & Flow Balancing Return Module air 4 pair 2

15 TwistSeal Manifold Accessories ressure Test Kit Stk# 7995 ressure test kit for use with TwistSeal and TwistSeal Mini (40 mm) manifolds. Replaces automatic air vent on cross tee for testing purposes. Kit includes two " plugs and 4 red rubber gaskets (2 are spares). For air tests use the red rubber gaskets; for hydrostatic tests use green fibre gaskets (included in manifold assembly kits) ressure Test Kit ea. Radiant Heating & Cooling Tubing to Manifold Connector for TwistSeal Manifolds Series Solid brass fitting attaches to the end of the EX tubing and allows for easy installation onto the bottom of the manifold module " Tubing to Manifold connector 0 pair " Tubing to Manifold connector 0 pair " Tubing to Manifold connector 0 pair " Tubing to Manifold connector with nut 0 pair Tubing to Manifold Connectors 2000 Series lastic fitting is installed into the bottom of the manifold module and is held in place by the nut. The tubing is then pressed on to this fitting. SS press sleeves sold separately " EX Insert Manifold Connector 5 ea " EX Insert Manifold Connector with nut 5 ea.

16 Stainless Steel Manifolds Common Features: reassembled configurations from 2 to 2 loops. Integrated " FT isolation valves and hosebibs. Zone valve return balancing with manual shut-off; accepts optional actuators. 2", 5 8", and 4" tubing to manifold connectors available Series Series L to R 2", 5 8", & 4" tubing to manifold connectors L to R port cap, 2", 5 8", & 4" tubing to manifold connectors ( loop model shown with 4 actuators, automatic air vent, 2" plug, port cap, and pressure bypass valve) Model Specific Features: Balancing supply with 0-.5 US gpm (0-5 L/min) flow meter. Typical Applications: Residential. Small commercial. ( loop model shown with 2 actuators and side mount automatic air vent) Model Specific Features: Balancing supply. Typical Applications: Commercial. Snow melting. # of loops Recommended Housing* Recessed Surface Mount Tubing Size Tubing to Manifold Connectors / Loop Conduit Elbows / Loop for Wet Installation 2" " " Manifold Series Stainless Steel (7600 or series) Actuator with LED Actuator with End Switch DDC Actuator (white ring) *recommended housing based on 90 mains piping

17 Stainless Steel Manifolds Stainless Steel Manifolds 7600 Series Manifold includes: assembled flow balancing supply manifold with " FT isolation valve and hose bib/air vent assembled balancing shut-off return manifold with " FT isolation valve and hose bib/air vent 2 mounting brackets Connectors & port caps sold separately Loop SS Manifold with Flow Meter Balancing Supply and Z.V. Return ea. 760 Loop SS Manifold with Flow Meter Balancing Supply and Z.V. Return ea Loop SS Manifold with Flow Meter Balancing Supply and Z.V. Return ea Loop SS Manifold with Flow Meter Balancing Supply and Z.V. Return ea Loop SS Manifold with Flow Meter Balancing Supply and Z.V. Return ea Loop SS Manifold with Flow Meter Balancing Supply and Z.V. Return ea Loop SS Manifold with Flow Meter Balancing Supply and Z.V. Return ea Loop SS Manifold with Flow Meter Balancing Supply and Z.V. Return ea Loop SS Manifold with Flow Meter Balancing Supply and Z.V. Return ea. 76 Loop SS Manifold with Flow Meter Balancing Supply and Z.V. Return ea Loop SS Manifold with Flow Meter Balancing Supply and Z.V. Return ea. Radiant Heating & Cooling 5

18 Stainless Steel Manifolds Radiant Heating & Cooling Stainless Steel Manifolds Series Manifold includes: assembled balancing supply manifold with " FT isolation valve and hose bib/air vent assembled balancing shut-off return manifold with " FT isolation valve and hose bib/air vent 2 mounting brackets Connectors & port caps sold separately Loop SS Manifold with Balancing Supply and Z.V. Return ea Loop SS Manifold with Balancing Supply and Z.V. Return ea Loop SS Manifold with Balancing Supply and Z.V. Return ea Loop SS Manifold with Balancing Supply and Z.V. Return ea Loop SS Manifold with Balancing Supply and Z.V. Return ea Loop SS Manifold with Balancing Supply and Z.V. Return ea Loop SS Manifold with Balancing Supply and Z.V. Return ea Loop SS Manifold with Balancing Supply and Z.V. Return ea Loop SS Manifold with Balancing Supply and Z.V. Return ea. 762 Loop SS Manifold with Balancing Supply and Z.V. Return ea Loop SS Manifold with Balancing Supply and Z.V. Return ea. 6

19 Stainless Steel Manifold Accessories ort Caps for Stainless Steel Manifolds Stk# 7700 Caps off unused ports on the Stainless Steel Manifold SS Manifold ort Cap 0 pair Tubing to Manifold Connectors for Stainless Steel Manifolds 7700 Series Connects EX tubing to Stainless Steel Manifold. Radiant Heating & Cooling " Manifold Connector for SS Manifold 0 pair " Manifold Connector for SS Manifold 0 pair " Manifold Connector for SS Manifold 0 pair Stainless Steel Manifold Coupling Stk# 7600 Used to connect SS manifolds together SS Manifold Coupling ea. 2" lug for Stainless Steel Manifold Stk# lug to seal SS manifold outlet " lug for SS Manifold ea. Automatic Air Vent for Stainless Steel Manifold Stk# 7692 Add an automatic air vent to the SS manifold by replacing a valve Automatic Air Vent for SS Manifold ea. 7

20 Stainless Steel Manifold Accessories Radiant Heating & Cooling Side Mount Automatic Air Vent Set for Stainless Steel Manifold Stk# 7695 Add an automatic air vent to the SS manifold without occupying a loop Side Mount Automatic Air Vent Set for SS Manifold ea. ressure Bypass Kit for Stainless Steel Manifold Stk# 7697 This valve prevents a steep rise of the pump head and maintains flow at a stable rate. Also ensures only required amount of cir cu lat ing water is used for hydronic systems. The valve can be ad just ed to any point between 0.05 and 0.5 bar (.67 and 6.7 ft H 2 O) ressure Bypass Kit for SS Manifold ea. HeatLink Strap-on Thermometer Stk# This surface mounted thermometer is used to measure surface temperatures of metallic piping. The Strap-on Thermometers can be mounted on pipe sizes ranging from 8" to - 2". Suggested applications: Use on stainless steel manifolds or supply and return piping to measure water temperatures. Range: 0-00 C, 2-22 F (dual scale) Strap-on Thermometer ea. 8

21 Manifold Housings Features & Benefits allows easy access to manifold visible parts made of satin coated steel and are ready to paint without priming cover enables a structural flush seal locking, removable (lift off) door stylish ventilation apertures to prevent build up of heat and formation of condensation openings for mains piping on left & right sides (recessed only) Stk. # Width Height Depth Maximum # of Loops with Manifold Assembly Kit #: Max # of SS Manifold Loops 7400 Series: Surface Mounted Manifold Housing " (60 mm) 0" (762 mm) 5-2" (40 mm) " (762 mm) 0" (762 mm) 5-2" (40 mm) " (067 mm) 0" (762 mm) 5-2" (40 mm) Series: Recessed Manifold Housing " (60 mm) 2" (584 mm) - 7 8" (98 mm) " (768 mm) 2" (584 mm) - 7 8" (98 mm) " (05 mm) 2" (584 mm) - 7 8" (98 mm) Installation Methods: 2 Allowance for 90 mains piping. 2 Allowance for straight isolation valves. Manifolds only, no piping allowances.

22 Manifold Housings Radiant Heating & Cooling Manifold Housing: Recessed 7700 Series Allows easy access to the manifold through its locking, removable door. Features: visible parts made of satin coated steel, surfaces ready to paint without priming, and stylish ventilation apertures to prevent build up of heat and formation of condensation. New! 7724 Recessed Manifold Housing 24" 2" - 7 8" ea. New! 770 Recessed Manifold Housing 0" 2" - 7 8" ea. New! 774 Recessed Manifold Housing 4-2" 2" - 7 8" ea. Manifold Housing: Surface Mount 7400 Series Allows easy access to the manifold through its locking, removable door. Features: made of satin coated steel, surfaces ready to paint without priming, and stylish ventilation apertures to prevent build up of heat and formation of condensation. New! 7424 Surface Mounted Manifold Housing 24" 0" 5-8" ea. New! 740 Surface Mounted Manifold Housing 0" 0" 5-8" ea. New! 7442 Surface Mounted Manifold Housing 42" 0" 5-8" ea. Key Lock for Manifold Housing Door Stk# 7902 Key lock that can field replace the standard coin/screwdriver lock of manifold housings (7700 and 7400 Series). New! 7902 Key Lock for Housing Door ea. 20

23 EX Compression Adapters EX Tubing Compression Couplings Series Solid brass fittings couples EX tubing to EX tubing " 8" EX Comp. Coupling 25 ea " 2" EX Comp. Coupling 25 ea " 5 8" EX Comp. Coupling 25 ea " 4" EX Comp. Coupling 25 ea " " EX Comp. Coupling 25 ea. Radiant Heating & Cooling EX Compression to MT Adapters Series Solid brass fittings converts EX tubing to male NT thread. Note: When used with EX tubing there is a risk of thermal expansion / contraction due to temperature fluctuation. It is recommended that a swing joint or expansion loop is installed at the high temp (supply) end of the tubing " EX 2" MT Adapter 25 ea " EX 2" MT Adapter 25 ea " EX Comp. 4" MT Adapter 25 ea " EX Comp. 4" MT Adapter 25 ea " EX Comp. " MT Adapter 25 ea " I.D. (40.7mm) EX Comp. - 4" MT Adapter 40 ea " I.D. (50 4.6mm) EX Comp. - 4" MT Adapter 2 ea " I.D. (6 5.7mm) EX Comp. 2" MT Adapter 6 ea " I.D. (75 6.8mm) EX Comp. 2" MT Adapter 2 ea " I.D. (90 8.2mm) EX Comp. " MT Adapter 7 ea " I.D. (0 0mm) EX Comp. " MT Adapter 4 ea. 2

24 EX Compression Adapters and Couplings Radiant Heating & Cooling EX Compression to 90 Female Sweat Elbows 6700 & Series Solid brass fittings converts EX tubing to female copper pipe. Ideal for baseboard connections " EX Comp. 2" F/Sweat 90 Elbow 25 ea " EX Comp. 4" F/Sweat 90º Elbow 25 ea " EX Comp. 4" F/Sweat 90 Elbow 25 ea. EX Compression to Female Sweat Adapters 6700 & Series Solid brass fittings converts EX tubing to female copper pipe " EX Comp. 2" F/Sweat Adapter 25 ea " EX Comp. 4" straight F/Sweat Adapter 25 ea " EX Comp. 4" F/Sweat Adapter 25 ea " EX Comp. 2" M/Sweat Adapter 25 ea. EX Compression to Male Sweat Adapters Series Solid brass fittings converts EX tubing to male copper pipe " EX Comp. 4" M/Sweat Adapter 25 ea " EX Comp. 4" M/Sweat Adapter 25 ea. 22

25 2-way Injection Mixing rimary Supply Radiant Heating & Cooling Secondary Supply 4 2 rimary Return Secondary Return Components HeatLink Injection Valve (62000 series; page 0) 2 HeatLink Balancing Valve (#6225, page 29) Secondary ump 4 HeatLink ressure Activated Bypass Valve (60000 series page ) Control Options Setpoint 5 HeatLink Thermostatic Head with Capillary (#57094; page ) Setpoint or Outdoor Reset 6 HeatLink Compact Mixing Reset Control (#55; page 4) 7 HeatLink 24Vac DDT ump Relay (#452; see page 9) 8 HeatLink DDC Actuator (#562; page 4) Note: Not all required components are shown. Local codes, regulation, and authorities have final jurisdiction. 2

26 -way Compact Mixing System Radiant Heating & Cooling rimary Supply Secondary Supply rimary Return Secondary Return Components HeatLink Compact -way Mixing Valve (6700 series; page 28) 2 Secondary ump HeatLink ressure Activated Bypass Valve (60000 series page ) MECHANICAL ROOM IN A BOX Control Options Setpoint 4 HeatLink Thermostatic Head with Capillary (#57094; page ) Setpoint or Outdoor Reset 5 HeatLink Compact Mixing Reset Control (#55; page 4) 6 HeatLink 24Vac DDT ump Relay (#452; see page 9) 7 HeatLink DDC Actuator (#562; page 4) anel Alternatives TM series - pages 6-64 TWH series - pages CD series - pages 69-7 SST series - page 76 Note: Not all required components are shown. Local codes, regulation, and authorities have final jurisdiction. 24

27 -way Mixing System rimary Supply Radiant Heating & Cooling Secondary Supply rimary Return 2 Secondary Return Components HeatLink -way Mixing Valve (6500 series; page 28) 2 Secondary ump HeatLink ressure Activated Bypass Valve (60000 series; page ) Control Options Setpoint or Outdoor Reset 4 HeatLink Compact Mixing Reset Control (#55; page 4) 5 HeatLink 24Vac DDT ump Relay (#452; see page 9) 6 HeatLink Mixing Valve Motor (5800 series; page 2) Snow melt (not shown) HeatLink Snow/Ice Detector & Melting Control (#667; page 4) HeatLink Snow/Ice Detector (#0090, 009; page 4) 6 HeatLink Mixing Valve Motor (5800 series; page 2) MECHANICAL ROOM IN A BOX anel Alternatives CD0R - page 72 ZM series - page 77 SM series - page 78 Note: Not all required components are shown. Local codes, regulation, and authorities have final jurisdiction. 25

28 4-way Mixing System Radiant Heating & Cooling Secondary Supply rimary Supply 2 Secondary Return rimary Return Components HeatLink 4-way Mixing Valve (64000 series; page 27) 2 Secondary ump HeatLink ressure Activated Bypass Valve (60000 series; page ) Control Options Setpoint or Outdoor Reset 4 HeatLink Compact Mixing Reset Control (#55; page 4) 5 HeatLink 24Vac DDT ump Relay (#452; see page 9) 6 HeatLink Mixing Valve Motor (5800 series; page 2) Snow melt (not shown) HeatLink Snow/Ice Detector & Melting Control (#667; page 4) HeatLink Snow/Ice Detector (#0090, 009; page 4) 6 HeatLink Mixing Valve Motor (5800 series; page 2) Note: Not all required components are shown. Local codes, regulation, and authorities have fi nal jurisdiction. 26

29 Mixing Valves & Mixing Block Mixing Block with ump and ressure Bypass Stk # 64 The Mixing Block incorporates a 4-way mixing valve, pressure bypass valve, and pump. Accepts mixing valve motor 580 (page 2) for automated 4-way mixing valve control. Radiant Heating & Cooling 64 Mixing Block with ump and ressure Bypass ea. 4-way FT Mixing Valves Series This unit mixes high temperature boiler water with heating return water to create a supply water temperature. It has the option of manual op er a tion, or it can be fitted with a mixing valve motor for fully automatic operation. " & - 4" valves use #580 motor (page 2). - 2" & 2" valves use #5850 motor (page 2). " Cv =.6 (Kvs = 0) - 4" Cv = 7.4 (Kvs = 5) - 2" Cv = 29 (Kvs = 25) 2" Cv = 46.4 (Kvs = 40) " 4-way FT mixing valve ea " 4-way FT mixing valve ea " 4-way FT mixing valve ea " 4-way FT mixing valve ea. 4-Way Flange Mixing Valves 6400 Series This unit mixes high temperature boiler water with heating return water to create a supply water temperature. It has the option of manual op er a tion, or it can be fitted with a mixing valve motor (#5899, see page 2) for fully automatic operation. 2-2" Cv = 7. (Kvs = 6) " Cv = 6. (Kvs = 00) 4" Cv = 86 (Kvs = 60) " 4-way Flange mixing valve ea " 4-way Flange mixing valve ea " 4-way Flange mixing valve ea. 27

30 Mixing Valves Radiant Heating & Cooling Compact -Way Mixing Valves 6700 Series Three-way mixing valve for fluid temperature control in heating and cooling systems. Bronze valve body with brass nipples, protective cap, and stainless spindle with double O-ring seal. Threads are compatible with actuators (#5620, #562, #562 (white ring); page 4) and thermostatic heads (#5709 and #57094; page ). 2" Cv = 2.9 (Kv = 2.5) 4" Cv = 4. (Kv =.5) " Cv = 5. (Kv = 4.6) - 4" Cv = 7.4 (Kv = 6.4) 676 2" Compact -way Mixing Valve ea " Compact -way Mixing Valve ea " Compact -way Mixing Valve ea " Compact -way Mixing Valve ea. -way FT Mixing Valves 6500 Series This unit mixes high temperature boiler water with heating return water to create a supply water temperature. It has the option of manual op er a tion, or it can be fitted with a mixing valve motor (#5850, page 2) for fully automatic operation. - 2" Cv = 29 (Kvs = 25) 2" Cv = 46.4 (Kvs = 40) " -way FT Mixing Valve ea " -way FT Mixing Valve ea. " -Way Diverter Valve Stk# 6025 rovides on/off or modulated flow control with bypass for man i folds or mis cel la ne ous sup ple men tal heating units. Fitted with three " sweat unions. Threads are compatible with actuators (#5620, #562, #562 (white ring); page 4) and thermostatic heads (#5709 and #57094; page ). Cv = 6.0 (Kv = 5.2) 6025 " Way Diverting Valve ea. 28

31 Valves Straight Balancing Valve " Female Sweat Stk# 6225 Flow balancing valve for use in injection systems and with the sidestream filter Straight Balancing Valve " Female Sweat 24 ea. Radiant Heating & Cooling 90 Angle Radiator Valves 6200 Series rovides on/off or modulated flow control for miscellaneous supplemental heating units (e.g. towel warmers). Nickel plated. Threads are compatible with actuators (#5620, #562, #562 (white ring); page 4) and thermostatic heads (#5709 and #57094; page ). 2" Cv =.6 (Kv =.5) 4" Cv = 2.9 (Kv = 2.5) Angle Radiator Valve 2", nickel plated 5 ea Angle Radiator Valve 4", nickel plated 20 ea. Straight Radiator Valves Series rovides on/off or modulated flow control for miscellaneous sup ple men tal heating units (e.g. towel warmers). Nickel plated. Threads are compatible with actuators (#5620, #562, #562 (white ring); page 4) and thermostatic heads (#5709 and #57094; page ). 2" Cv =.6 (Kv =.5) 4" Cv = 2.9 (Kv = 2.5) 6226 Straight Radiator Valve 2", nickel plated 20 ea Straight Radiator Valve 4", nickel plated 20 ea. 29

32 Valves Radiant Heating & Cooling Straight Zone Valves/Injection Valves Series rovides on/off or modulated flow control for baseboard, fan coils, manifolds, and injection controls. Threads are compatible with actuators (#5620, #562, #562 (white ring); page 4) and thermostatic heads (#5709 and #57094; page ). 2" Cv = 2.9 (Kv = 2.5) 4" Cv = 4.2 (Kv =.6) " Cv = 4.9 (Kv = 4.2) - 4" Cv = 6.8 (Kv = 5.8) 6206 Straight Zone Valve 2" 5 ea Straight Zone Valve 4" NT ea Straight Zone Valve " NT ea Straight Zone Valve - 4" NT ea. 2" Straight Return Connector Stk# 606 rovides balancing for miscellaneous sup ple men tal heating units (e.g. towel warmers). Gives a clean exposed finish when used with the HeatLink zone valves in supplemental heat applications. Nickel plated. Cv =.6 (Kv =.5) 606 Straight Return Connector 2" 20 ea. 2" 90 Angle Return Connector Stk# 66 rovides balancing for miscellaneous sup ple men tal heating units (e.g. towel warmers). Gives a clean exposed finish when used with the HeatLink zone valves in supplemental heat applications. Nickel plated. Cv =.6 (Kv =.5) Angle Return Connector 2" 5 ea. 0

33 Valves ressure Activated Bypass Valve Series This valve prevents a steep rise of the pump head and maintains flow at a stable rate. Also ensures only required amount of cir cu lat ing water is used for hydronic systems. The 4" valve can be ad just ed to any point between.5 and 7 ft H 2 O (50 and 500 mbar). The " and - 4" can be adjusted to any point between 0 and 60 ft H 2 O (0 and 800 mbar). 4" max. flow = US gpm (2950 L/h) " max. flow = 22 US gpm (5000 L/h) - 4" max. flow = 5 US gpm (7950 L/h) Radiant Heating & Cooling ressure activated bypass valves 4" 5 ea ressure activated bypass valves " 5 ea ressure activated bypass valves - 4" 5 ea.

34 Mixing Valve Motors Radiant Heating & Cooling Mixing Valve Motor for " & - 4" Valves Stk# 580 Used to automatically operate the 4-way mixing valve. The motor is re vers ible and is provided with fixed limit switches. For use with " and - 4" mixing valves and mixing block (64025, 6400, and 64; page 27). 24 Vac 50/60 Hz 2 VA 580 Mixing valve motor for " and - 4" valves ea. Mixing Valve Motor for - 2" & 2" Valves Stk# 5850 Used to automatically operate the 4-way mixing valve. The motor is re vers ible and is provided with fixed limit switches. For use with - 2" and 2" mixing valves (6540, 6550, 64040, and 64050; page 27). 24 Vac 50/60 Hz 2 VA 5850 Mixing valve motor for - 2" and 2" valves ea. Mixing Valve Motor for 2-2", ", and 4" Valves Stk# 5899 Used to automatically operate the 4-way flange mixing valve. The motor is re vers ible and is provided with fixed limit switches. For use with flanged 2-2", ", and 4" mixing valves (6465, 6880, and 6499; page 27). 24 Vac 50/60 Hz 2 VA 5899 Mixing Valve Motor for 2-2", ", and 4" Flange MVs ea. 2

35 Thermostatic Heads Thermostatic Head Stk# 5709 Thermostatic head for HeatLink zone valves. Maximum setting 84 F (29 C). Senses 0.4 F (0.2 C) air temperature change. Takes 24 minutes to close from full open Thermostatic Head (6-28 C) ea. Radiant Heating & Cooling Thermostatic Head with 6' (.8 m) Remote Cap il lary Stk# Used as injection control for HeatLink zone valves. Senses 0.4 F (0.2 C) supply water change. Takes 5 minutes to close from full open. Temperature adjustment range: F (6-66 C) Thermostatic Head c/w Capillary (96-50 F) ea.

36 Actuators Radiant Heating & Cooling 5620/ 5622 Actuator c/w End Switch 5620 Series These motors allow for additional room temperature control in con junc tion with a room thermostat by mounting on a TwistSeal supply man i fold module (5620), Stainless Steel Manifold (562), HeatLink & 6000 series zone valves (562), or TwistSeal Multiport Manifold (5622). Comes complete with end switch to allow pump and/or boiler switching HeatLink TwistSeal Manifold actuator w/ End Switch 00 ea. 562 HeatLink Valve & SS Manifold actuator w/ End Switch 00 ea HeatLink Multiport Manifold actuator w/end Switch 00 ea / Actuator Series These actuators allow for additional room temperature control in con junc tion with a room thermostat by mounting on a TwistSeal supply man i fold module (56200), Stainless Steel Manifold (5620), HeatLink & 6000 series zone valves (5620), or TwistSeal Multiport Manifold (56202). Includes a heat demand LED indicator HeatLink TwistSeal Manifold actuator w/ LED 00 ea HeatLink Valve & SS Manifold actuator w/ LED 00 ea HeatLink Mulitport Manifold actuator w/led 00 ea. How to tell the 562x0 and 562x actuators apart Actuator LED End Switch Female Thread Center in Mounts on Yes No Fine Yes TwistSeal & Yes No Coarse No Valves & SS manifolds 5620 No Yes Fine Yes TwistSeal & No Yes Coarse No Valves & SS manifolds / / 562 DDC Actuators Stk# 562 These actuators allow for additional room temperature control when used in conjunction with a direct digital control system by mounting on a TwistSeal supply man i fold module, Stainless Steel Manifold, or HeatLink & 6000 series zone valves. 562 HeatLink DDC Actuator for Manifolds & Valves 00 ea. 4

37 Stat Link You re in Control because every family has different needs, and every home is unique. A traditional forced air system with one central thermostat may need to be set higher than necessary to ensure that some parts of the house get sufficient heat. With HeatLink radiant floor heating, a house can be divided into different heating zones. Each zone will have it s own thermostat that will set it s temperature independently from the other zones. This means that you can heat only the rooms that need heat. Rooms that don t need to be heated can be put into setback, a lower user adjustable temperature, to save energy. Add a timer thermostat to automatically switch between normal operation and setback operation on a set schedule. This schedule will let you automatically lower the temperature of your home when no one s home and bring the temperature back up to greet you upon your return. Bedroom #2 Den Dining Room Living Room Kitchen Master Bedroom Garage Example: Living area is heated in the morning and evening, and setback during the day and at night. Bedrooms are heated during the night, and setback during the day. Less frequently used rooms can be manually switched to and from setback mode. Setback Channel - Living Area Normal operation Setback operation Setback Channel 2 - Bedrooms Normal operation Setback operation 24 hour schedule

38 Stat Link Electronic Control System HeatLink did some simple addition, and came up with a significant innovation. By adding an LED on our new StatLink zone drive actuator, HeatLink has reduced the waiting time. The LED immediately indicates heat demand. Along with our new thermostats and zone modules, the result is a completely visual feedback system. To sum it up, it s situation normal at-a-glance. We ve also gone color-coded and digital. Of the five thermostats StatLink now offers, one is mechanical, one is electronic, and three are digital. The manual or automatic setback on the electronic and digital thermostats, provide energy savings by lowering the temperature of unoccupied rooms. All thermostats are designed for use with standard AWG 8 cable. Our screw terminals are color-coded to match the wire colors found in fire-alarm cable (FAS05). Our StatLink modules simplify the whole wiring process, and eliminate that tangled mess of wires. The color-coded screw terminals indicate where each wire goes in the heating zones. Each zone has an LED indicator for heat demand, and up to 4 actuators can be connected to each zone. It also acts as a combined end-switch for all zones, by activating the boiler and pump when heat is required. HeatLink s new StatLink system saves the contractor both time and money, by focusing on ease of installation and ease of use. The new StatLink is a welcome addition to the HeatLink family, and our customers will find it is an excellent fit with our other product lines. Electronic Thermostat #4644 analog electronic regulation heat demand LED large, easy to adjust dial position operation selector switch: heat, manual or automatic (external timer) setback setback of 4 C (7 F) or 4 wire operation internal or external sensor operation Dual Dry Contacts Digital Thermostat #4654 proportional integral temperature regulation fully menu driven large digital display manual or automatic (external timer) setback adjustable setback temperature room, fl oor or combined sensor operation adjustable characteristics for system optimization (high mass, low mass, baseboard, fan coil and cooling) external sensor 24Vac ower

39 Digital Timer Thermostat #4664 proportional integral temperature regulation fully menu driven large digital display easy to program 7 day 24 hour timer with 4 user programs and 9 fi xed programs room, fl oor or combined sensor operation setback signal feedback to StatLink ITCS function for intelligent setback functionality adjustable characteristics for system optimization (high mass, low mass, baseboard, fan coil and cooling) Digital Heat/Cool Timer Thermostat #4667 proportional integral temperature regulation fully menu driven large digital display easy to program 7 day 24 hour timer with 4 user programs and 9 fi xed programs room, fl oor or combined sensor operation setback signal feedback to StatLink ITCS function for intelligent setback functionality adjustable characteristics for system optimization (high mass, low mass, baseboard, fan coil and cooling) heat, cool, fan, or automatic operation cooling contacts StatLink 6 Zone Base Module - # Vac input boiler and pump switching via dual dry contacts heat demand LEDs for each zone up to 4 actuators per zone max. 2 actuators with the addition of a 60VA transformer StatLink 4 Zone Expansion Module - #4024 (not shown) easy addition of 4 zones heat demand LEDs for each zone up to 4 actuators per zone Actuators #56200 Series heat demand LED indicator available with endswitch StatLink 2 Zone Heavy Duty Expansion Module - #40242 easy addition of 2 zones heat demand LEDs for each zone up to 2 actuators per zone

40 Thermostats Radiant Heating & Cooling Electronic Thermostat Stk# 4644 rovides analog electronic temperature regulation. Screw terminal connection for use with standard thermostat wire. position operation selector switch: heat, manual or automatic (external timer) setback. Includes heat demand LED. Optional external sensor HeatLink Electronic Thermostat w/ LED & Setback Selector Switch ea. Digital Thermostat Stk# 4654 rovides proportional integral temperature regulation. Screw terminal connection for use with standard thermostat wire. Adjustable manual or automatic (external timer) setback. Features a fully menu driven large digital display. Offers optimization for various system types (high mass, low mass, baseboard, fan coil and cooling). Optional external sensor HeatLink Digital Thermostat w/ optional fl oor warming ea. Digital Timer Thermostat Stk# 4664 rovides proportional integral temperature regulation for maximum comfort and efficiency. Features a fully menu driven large digital display. Offers optimization for various system types (high mass, low mass, baseboard, fan coil and cooling). Take control with the easy to program 7 day 24 hour timer utilizing 9 preset programs and the ability to program 4 additional user programs. This thermostat is capable of generating a setback signal that can be best utilized with a StatLink module and shared with other thermostats. Optional external sensor HeatLink Digital Timer Thermostat ea. Digital Heat/Cool Timer Thermostat Stk# 4667 rovides proportional integral temperature regulation for maximum comfort and efficiency. Features a fully menu driven large digital display. Offers optimization for various system types (high mass, low mass, baseboard, fan coil and cooling). Take control with the easy to program 7 day 24 hour timer utilizing 9 preset programs and the ability to program 4 additional user programs. This thermostat is capable of generating a setback signal that can be best utilized with a StatLink module and shared with other thermostats. Operational modes consist of: heat, cool, fan, or automatic. Optional external sensor HeatLink Digital Heat/Cool Timer Thermostat ea. 8

41 24V AC Relay 24V AC DDT ump Relay Stk# 4502 Double pole double throw relay used for pump and/or boiler control. Use with socket #4502 sold separately. Contacts: 0A resistive, 7.5A 0 Vac, 4 hp. 7.5A resistive, 5.0A 220 Vac, hp Vac DDT pump relay ea. 24V AC DDT ump Relay Socket Stk# 4502 Radiant Heating & Cooling Socket for 24V AC DDT pump relay #4502. Easily mounted on DIN rail pin round Socket for AC relay ea. 24V AC DDT ump Relay Box Stk# 452 Electrical enclosure complete with #4502 relay, #4502 socket, and DIN rail. Contacts: 0A resistive, 7.5A 0 Vac, 4 hp. 7.5A resistive, 5.0A 220 Vac, hp. 452 HeatLink 24Vac DDT pump relay Box ea. 9

42 StatLink Modules Radiant Heating & Cooling StatLink 6 Zone Base Module Stk# The StatLink 6 zone base module is complete with all the main electrical connections for a hydronic floor heating system. This module can be mounted either on a DIN rail or directly to a wall. It connects room thermostats to their corresponding actuators. Each zone has an LED which indicates if it is calling for heat. A timer thermostat (#4664 or #4667) can send a setback signal to other thermostats via terminal Clock or 2. As soon as there is a heat demand from one zone, a relay with two dry contacts is switched on (ump, Boiler ). Add more zones by plugging in the #4024 or #40242 module. The 6 zone base module has a current rating of 2.5A; a 60VA transformer allows for 20 actuators per base module to be connected with up to 4 actuators per zone StatLink 6 Zone Base Module ea. StatLink 4 Zone Expansion Module Stk# 4024 The StatLink 4 zone expansion module connects to the StatLink 6 zone base module, allowing 4 more room thermostats to connect to their corresponding actuators. The 4 zone expansion module has a current rating of 2.5A StatLink 4 Zone Expansion Module ea. StatLink 2 Zone Heavy Duty Expansion Module Stk# The StatLink 2 zone heavy duty expansion module connects to the StatLink 6 zone base module or power module, allowing 2 more room thermostats to connect to up to 2 actuators each. Note: max. 60 VA transformer allows for up to 20 actuators. The 2 zone heavy duty expansion module has a current rating of 2.5A StatLink 2 HD Zone Expansion Module ea. Installation Track for StatLink Modules Stk# 4425 Allows for easy and fast installation of all control modules. Length = 25" 4425 StatLink Installation track, 25" ea. 40

43 Controls HeatLink One Stage Setpoint Control Stk# 050 One stage SDT heating and cooling setpoint control. ulse width modulation or bang-bang operation. Features adjustable differential and adjustable delay or cycle. universal sensor is included. 24 Vac 50/60 Hz VA 050 One stage Setpoint Control ea. Radiant Heating & Cooling HeatLink Compact Mixing Reset Control Stk# 55 The 55 Compact Mixing Reset Control regulates the supply water temperature of an automated mixing valve in order to provide outdoor reset or setpoint operation. The 55 provides a floating action (-way or 4-way mixing) or a 0/2 0 V(dc) (2-way injection) signal to adjust the mixing valve position. The 55 also includes two separate night setback channels. Outdoor sensor and universal sensor are included. 24Vac 50/60 Hz 50 VA (max) 55 HeatLink Compact Mixing Reset Control ea. HeatLink Snow/Ice Detector & Melting Control - Floating Action / Variable Speed Stk# 667 The 667 Snow/Ice Detector & Melting Control is designed to control a single zone snow melting system. The snow melting system may be started manually or automatically through the use of a Snow / Ice Sensor The control automatically adjusts the mixed supply water to the snow melting system by controlling a variable speed pump or floating action mixing valve. The 667 control includes a large Liquid Crystal Display (LCD) in order to view system status and operating information. Outdoor sensor and 2 universal sensors are included. 20 Vac 50/60 Hz 600 VA 667 HeatLink Snow/Ice Detector & Melt Control ea. 4

44 Sensors Radiant Heating & Cooling Snow Melt Kit Stk# 0092 The snow melt kit is used to remotely enable and disable the snow melting system through a single button. Snow melting run time is adjustable through a dial. An LED provides a visual indication of the operation of the snow melting system. For use with 667 control Snow Melt Kit ea. Universal Sensor Stk# 007 Standard sensor for use as optional sensor in 0000 series controls. 007 Universal Sensor (0K) 0 ea. Slab Sensor - VC Sleeve Stk# 0072, 007 Sensors for use in measuring slab or ground temperatures. The 0072 and 007 standard sensors with VC sleeve are designed for use in soil or concrete. For use with 0000 series controls Slab Sensor (0K) VC sleeve 20' cable ea. 007 Slab Sensor (0K) VC sleeve 40' cable ea. Slab Sensor - Stainless Steel Sleeve Stk# 0079 Sensors for use in measuring slab or ground temperatures. The 0079 sensor with stainless steel sleeve is designed for use in concrete, thin-set and grout. For use with 0000 series controls Slab Sensor (0K) stainless steel sleeve 0' cable ea. 42

45 Sensors Indoor Sensors Stk# 0076, 0077 These 0k sensors provide accurate measurement of the indoor air tem per a ture. The 0076 sensor can be mounted directly on the wall using two #6 - " screws. The 0077 sensor can be mounted flush onto a stan dard duplex electrical box. For use with 0000 series controls Indoor Sensor (0K) small enclosure ea Indoor Sensor (0K) fl ush mount ea. Radiant Heating & Cooling Snow/Ice Detector (Sensor) Stk# 0090, 009 This snow/ice sensor in conjunction with the 667, ac ti vates and con trols a snow melting system based on moisture (snow/ice) and slab tem per a ture. This control is not designed as a simple de tec tion device and will not operate properly in an unheated slab Snow/Ice Sensor (0K) 65' cable ea. 009 Snow/Ice Sensor Socket ea. 4

46 Wet System Radiant Heating & Cooling Wall Stud Drywall Baseboard Tubing Tracking on Subfloor Installed on top of the subfloor with light weight concrete. Double lating Floor Joist Floor Covering Support Beam Foil-backed Insulation Foundation or Main Floor Bearing Wall Gypsum or Concrete HeatLink Tubing Tracking (page 49) HeatLink EX Tubing (see page 5) lywood Subfl oor Drywall Tubing Tracking on Subfloor Installed on top of the subfloor with light weight concrete (shown with sleepers for hardwood installation). Baseboard Wall Stud Double lating Floor Joist Support Beam Hardwood Floor Foil-backed Insulation Subfl oor Gypsum or Concrete Foundation or Main Floor Bearing Wall HeatLink EX Tubing (page 5) reliminary Subfl oor HeatLink Tubing Tracking (page 49) 44

47 Wet System Tubing Tracking on Insulation Used for basements or slab-on-grade homes. The EX tubing is encased in a concrete topping. Radiant Heating & Cooling Foundation Thermal Break Footing HeatLink EX Tubing (page 5) Floor Covering Gypsum or Concrete HeatLink Tubing Tracking with Track Staples (pages 49-50) Closed Cell High Density Insulation Vapor Barrier Gravel Bed Subsoil Tie Strap on Mesh/Rebar Used for basements or slab-on-grade homes. The EX tubing is encased in a concrete topping. Foundation Thermal Break Footing HeatLink EX Tubing (page 5) with Tie Straps (page 50) Floor Covering Gypsum or Concrete Closed Cell High Density Insulation Vapor Barrier Gravel Bed Subsoil 45

48 DryAbove System Dry system that eliminates the pain in the neck of overhead work No structural changes required Ideal for retrofits or remodeling Inexpensive components keep material costs low 4 DryAbove components: EndBend 4 2 SpacerClip Heat Transfer late 4 2 EX Tubing 2 2 2

49 DryAbove System Double Counter Flow Installed on top of the subfloor or existing floors for remodelling or additions. Wall Stud Drywall Baseboard lating EndBend (page 49) SpacerClip (page 49) HeatLink Heat Transfer late (see page 49) HeatLink 2" EX Tubing (see page 6) Sleepers erimeter Edging Radiant Heating & Cooling Subfl oor Floor Joist Floor Covering Support Beam Foil-backed Insulation Foundation or Main Floor Bearing Wall EndBend (page 49) SpacerClip (page 49) Wall Stud Drywall Baseboard lating Subfl oor Floor Joist Floor Covering Support Beam Foil-backed Insulation Foundation or Main Floor Bearing Wall HeatLink Heat Transfer late (page 49) HeatLink 2" EX Tubing (see page 6) Sleepers erimeter Edging Serpentine Installed on top of the subfloor or existing floors for remodelling or additions with solid hardwood floors. 47

50 DryBelow System Radiant Heating & Cooling Double Loop Installed between 2"/6" O.C. floor joists beneath the subfloor for retrofits or upper floors. Wall Stud Sill Floor Covering lywood Subfl oor Foundation or Main Floor Bearing Wall 2" / 6" O.C. Joist Space HeatLink Heat Transfer lates (page 49) Refl ective Insulation HeatLink EX Tubing (page 6) Triple Loop Installed between 6"/24" O.C. floor joists beneath the subfloor for retrofits or upper floors. Floor Covering lywood Subfl oor 6" / 24" O.C. Joist Space HeatLink Heat Transfer lates (page 49) Refl ective Insulation HeatLink EX Tubing (see page 6) 48

51 Floor Heating Accessories Aluminum Heat Transfer late Stk# This plating is used to provide a direct transfer and heat dis tri bu tion from the EX piping to a wooden subfloor. They can be stapled to the underside of the subfloor in a DryBelow system or used above the subfloor in a DryAbove system. End to end gaps between plates should be from " to 6" (75 to 50mm). lates measure 24" 4-4" (60 mm 08 mm) " Aluminum Heat Transfer late for DryAbove /DryBelow Systems ea. Radiant Heating & Cooling EndBend for DryAbove System Stk# The EndBend allows for transition on the loop ends as well as supports for supply & return piping EndBend for DryAbove System ea. SpacerClip for DryAbove System Stk# 8705 The SpacerClip is placed between the heat transfer plates and holds the tubing in place. Tubing can be stepped into clip SpacerClip for DryAbove System ea. Tubing Tracking: 8", 2" and 5 8" Stk# Tracking provides even tubing spacing and exact reg u la tion of tubing heights. They can be fastened to many surfaces, such as concrete or plywood subfloors, steel Q deck ing, and polystyrene in su la tion. Built in sup ports permit spacing in " (75 mm) multiples. Tracking comes in 4 ft (.22 m) lengths Tubing tracking ft. 49

52 Floor Heating Accessories Radiant Heating & Cooling Track Staples Stk# 8900 Staples are used to fasten tubing tracking to polystyrene insulation. The hooks on the ends ensure the staple will not loosen prior to topping pour Track Staples 8 bag Staples for Stand-up Stapler Series Staples for fastening up to 2" (or 8mm O.D.) EX tubing to polystyrene insulation. For use with Stand-up Stapler #0220 (discontinued) " (50 mm) HeatLink Staples for Stand-up Stapler 6 box " (60 mm) Staples for Stand-up Stapler 2 box Staples for Deluxe Staple Gun Series Staples for fastening up to 5 8" (or 20mm O.D.) EX tubing to polystyrene insulation. For use with HeatLink Deluxe Staple Gun #020. New! " Staples for HeatLink Deluxe Staple Gun 20 box New! " Staples for HeatLink Deluxe Staple Gun box HeatLink Tie Straps 8900 Series Used to fasten piping to wire mesh or rebar. 5-2" (40 mm) tie wraps (8905) are used for smaller diameter tubing. 7-2" (90 mm) tie wraps (8907) can be used for sizes up to " Tie Straps 5.5" 0 bag Tie Straps 7.5" 0 bag 50

53 Floor Heating Accessories Expansion Stripping Stk# This foam stripping provides expansion joint and sound barrier at the edge of the floor slab. Roll of 75 ft (2 m) ft roll Expansion stripping 7 roll Conduit Elbows Series Radiant Heating & Cooling High impact strength moulded plastic 90 long radius elbow, designed to direct and protect heating tubing in transition area where tubing enters and exits concrete slab " Conduit 90 s 00 ea " Conduit 90 s 50 ea " Conduit 90 s 40 ea " Conduit 90 s 00 ea. lastic Bend Support 8600 Series Allows for easy bending support and removal lastic Bend Support for 8" and 2" tubing ea lastic Bend Support for 4" tubing ea. Metal Bend Support Series Allows for easy bending support and removal. New! Metal Bend Support for 2" Tubing ea. New! 8629 Metal Bend Support for 5 8" Tubing ea. New! Metal Bend Support for 4" tubing ea. 5

54 Chemicals Radiant Heating & Cooling Molybdate Based Corrosion Inhibitor Stk# 0205 The Molybdate Based Corrosion Inhibitor creates a protective monomolecular film over all internal surfaces of the heating system as the water circulates. The film is an anodic coating which immediately stops corrosive attack of the metallic parts. Molybdate will not harm EX tubing or the manifolds and it is glycol compatible. Molybdate concentration between ppm is recommended; higher concentrations are not harmful. The Molybdate will act as a preoperational cleaner if a sidestream filter is installed and double the amount of Molybdate required is added. The molybdate concentration should be checked after this procedure. The contents of this L (0.26 US gal) container will treat 82 L (58 US gal) of water. Advantages: low toxicity; non-pollutant; non-staining 0205 L Corrosion Inhibitor (Molybdate based) bottle urging Compound (re & ost Operational Cleaner) Stk# 0 urging compound for boilers and closed loop systems. Used as a preoperational cleaner and a post start-up cleaner. The contents of this L (0.26 US gal) container will treat L (9 US gal) of water. Note: After refilling system with fresh water, ensure either a glycol or inhibitor as listed on the previous page is immediately added. 0 L urging Compound (re & ost Operational Cleaner) bottle ostoperational Filtration Cleaner Stk# 02 Scale conditioning additive. Must be used in conjunction with a sidestream filter. olymer based additive that promotes movement of precipitate into the filter. System can be cleaned while still in operation. The contents of this L (0.26 US gal) container will treat 000 L (264 US gal) of water. 02 Ltr ostoperational Filtration Cleaner ea. 52

55 (Both G and EG reported if glycol type unknown) Water Testing Molybdenum Test Kit Stk# 0020 Determines the amount of molybdate based corrosion inhibitor in the water. Includes: 50 ml plastic beaker Molybdenum titrating solution Molybdenum buffer solution Mixed indicator solution Note: Chemicals included have expiry dates 0020 Molybdenum Test Kit ea. Radiant Heating & Cooling Customer Information Date: Tag #: WAR #: HeatLink Water Quality Laboratory FAR # Job #: RMA #: Lab Technician: HeatLink reventative Maintenance Water Analysis Stk# 0042 roject: Distributor: Contractor: System Volume: L Fluid Analysis Results Glycol Freeze rotection: Nitrite Inhibitor: Molybdate Inhibitor: ph Level: Conductivity: Hardness: ( Grain/USG = 7.ppm) Bacteria/Mould Test: Comments: Source: Heating otable Water Snowmelt Other... Units Optimal Conditions % EG 0 or 20-50% glycol % G 0 or 20-50% glycol ppm ppm ppm 00-50ppm ph units us/cm uS/cm ppm -00ppm ositive Negative Not Tested Temperature F C F C Water analysis service provided by HeatLink that tests a water sample for: Glycol Nitrite Inhibitor Molybdate Inhibitor ph Level Conductivity Hardness Instructions: A water sample of ml (.5-7 fl. oz.) in a clean plastic bottle (e.g. wsb2) is required. Copy Transmitted: Date Transmitted: Wholesaler Contractor Agent Other 0042 HeatLink reventative Maintenance Water Analysis (requires wsb2) ea. Net #2 Water Sample Bottle w/cap - General Stk# wsb2 lastic bottle for collecting a water sample. wsb2 #2 Water Sample Bottle w/cap - General 24 ea. Net 5

56 Sidestream Filter Radiant Heating & Cooling Sidestream Filter Stk# 0225 The HeatLink sidestream filter is designed to remove precipitate (suspended solids) from the system fluid. recipitate can lead to increased wear and tear of components and decreased system efficiency. The 0225 filter (made of reinforced polypropylene) is chemically resistant to propylene & ethylene glycol and both molybdate and nitrite inhibitors. The 55 micron filter cartridge is easily cleaned and reusable, no replacement cartridges are necessary. For use on systems up to 600,000 BTU. One size fits all. " male NT thread connections Sidestream Filter ea. 54

57 Sidestream Filter Cleans system fluids. Extends life of heating system. rotects o-rings and seals. Maintains system efficiency. The 55 micron filter cartridge is easily cleaned and reused. No replacement cartridges are needed. For use in residential and commercial applications. The 55 micron filter is a column of stacked disks designed to remove precipitates as water passes through. There are no replacement filter cartridges to buy, as the disk system is easily removed, cleaned under a stream of warm water, and simply reinserted. For use on systems up to 600,000 BTU. One size fits all. Components HeatLink Sidestream fi lter (#0225) 2 Isolation (ball) valve Flow Indicator 4 HeatLink Balancing valve (#6225) 5 Low Temp. System ump

58 Heat Seal HeatSeal is a flexible insulated pipe system, designed for long and short water distribution networks and a variety of applications. HeatSeal piping systems are made of crosslinked polyethylene (EX) with oxygen diffusion barrier. EX is used for its long term stability, excellent thermal characteristics, and resistance to abrasion, corrosion and chemicals. Insulation consists of flexible, CFC free EX foam with excellent heat insulation properties. Corrugated HDE twin wall sheath provides a protective barrier against installation and backfill damage, superior weather resistance and water proofing. otable water transport, waste water, refrigeration, swimming pools, and agricultural applications are some of the many uses for this innovative product. Adaptable to a variety of construction site conditions HeatSeal is delivered directly to the construction site in cut to length coils which allow for quick installation with the least number of joints. Flexibility and ease of transportation means easy installation and adaptability to practically all construction projects. Since our products require considerably narrower piping trenches, civil engineering costs are significantly reduced. HeatSeal can bend around obstacles and the 9-7/8" 25 cm HeatSeal Dual inside bend radius shortest route can be chosen, regardless of conventional pipeline construction procedures. HeatSeal can also be used where trenching is not an option, such as horizontal drilling applications. A large selection of fittings & accessories offers solutions for every situation. The inherent cost savings, incredible versatility and quality of materials mean there is absolutely no better answer available! Call us today!

59 Insulated EX Tubing see page 2 for fittings Insulated Heating Tubing - Single 9700 Series HeatSeal is a flexible insulated tubing system, designed for long and short water distribution networks and a variety of applications. HeatSeal piping systems are made of crosslinked polyethylene (EX) with oxygen diffusion barrier. EX is used for its long term stability, excellent thermal characteristics, and resistance to abrasion, corrosion and chemicals. All sizes are certified by NSF to NSF-6 and NSF-4. " tubing is manufactured to ASTM F-876. Maximum operating temperature SI (95 6 bar). Insulation consists of flexible, CFC free EX foam with excellent heat insulation properties. Corrugated HDE twin wall sheath provides a protective barrier against installation and backfill damage, superior weather resistance and water proofing. Minimum Bend Radius is approx..5 the sheath diameter. Lengths shorter than 28' are subject to a cut charge. Radiant Heating & Cooling Stk# Description kg Qty Max. Carton Length Qty Unit Disc. List rice / Unit Special Order 970 " HeatSeal insulated EX-a Tubing 28 ft. H Special Order " I.D. (40.7mm) HeatSeal insulated EX-a Tubing - 2" I.D. (50 4.6mm) HeatSeal insulated EX-a Tubing 2" I.D. (6 5.7mm) HeatSeal insulated EX-a Tubing 2-2" I.D. (75 6.9mm) HeatSeal insulated EX-a Tubing " I.D. (90 8.2mm) HeatSeal insulated EX-a Tubing 4" I.D. (0 0.0mm) HeatSeal insulated EX-a Tubing 28 ft. H 28 ft. H 28 ft. H 28 ft. H 28 ft. H 28 ft. H Cut Custom Coil Cutting ea. Net * Special order item #970 subject to lead time of 8 weeks and minimum order. ** Special order item #9702 subject to lead time of 8 weeks. 57

60 Insulated EX Tubing Radiant Heating & Cooling see page 2 for fittings Insulated Heating Tubing - Dual Series HeatSeal is a flexible insulated tubing system, designed for long and short water distribution networks and a variety of applications. HeatSeal piping systems are made of crosslinked polyethylene (EX) with oxygen diffusion barrier. EX is used for its long term stability, excellent thermal characteristics, and resistance to abrasion, corrosion and chemicals. All sizes are certified by NSF to NSF-6 and NSF-4. " tubing is manufactured to ASTM F-876. Maximum operating temperature SI (95 6 bar). Insulation consists of flexible, CFC free EX foam with excellent heat insulation properties. Corrugated HDE twin wall sheath provides a protective barrier against installation and backfill damage, superior weather resistance and water proofing. Minimum Bend Radius is approx..5 the sheath diameter. Lengths shorter than 28' are subject to a cut charge. Stk# Description kg Qty Max. Carton Length Qty Unit Disc. List rice / Unit 9702 " Dual HeatSeal insulated EX-a Tubing 28 ft. H " I.D. (40.7mm) Dual HeatSeal insulated EX-a Tubing 28 ft. H " I.D. (50 4.6mm) Dual HeatSeal insulated EX-a Tubing 28 ft. H " I.D. (6 5.7mm) Dual HeatSeal insulated EX-a Tubing 28 ft. H Cut Custom Coil Cutting ea. Net 58

61 HeatSeal Accessories Dry End Caps 8000 Series End cap to protect insulation in areas where moisture is not a problem. Special Order 80 HeatSeal " Endcap (Dry) ea. Special Order 802 HeatSeal - 4" Endcap (Dry) ea. 80 HeatSeal - 2" Endcap (Dry) ea. 804 HeatSeal 2" Endcap (Dry) ea. 805 HeatSeal 2-2" Endcap (Dry) ea. 806 HeatSeal " Endcap (Dry) ea. 807 HeatSeal 4" Endcap (Dry) ea. 802 HeatSeal " Dual Endcap (Dry) ea HeatSeal - 4" Dual Endcap (Dry) ea. 802 HeatSeal - 2" Dual Endcap (Dry) ea HeatSeal 2" Dual Endcap (Dry) ea. Radiant Heating & Cooling Wet End Cap 800 Series End cap to protect insulation in areas where moisture is a problem. It is shrunk on to the pipe by applying a gas flame or hot air. 8 HeatSeal - 2" Shrink Cap (Wet) ea. 84 HeatSeal 2" Shrink Cap (Wet) ea. 85 HeatSeal 2-2" Shrink Cap (Wet) ea. 86 HeatSeal " Shrink Cap (Wet) ea. 87 HeatSeal 4" Shrink Cap (Wet) ea. 82 HeatSeal " Dual Shrink Cap (Wet) ea. 822 HeatSeal - 4" Dual Shrink Cap (Wet) ea. 82 HeatSeal - 2" Dual Shrink Cap (Wet) ea. 824 HeatSeal 2" Dual Shrink Cap (Wet) ea. * Special order items subject to lead time of 8 weeks. 59

62 HeatSeal Accessories Radiant Heating & Cooling Coupling Hard Shell - all regular sizes Once the HeatSeal pipes are connected, this casing provides additional insulation and seals the outer jacket. The set comes with stone wool, a ready to use bitumen rubber kit, stainless steels bolts and an instruction leaflet. For use with all pipe sizes except " single HeatSeal Coupling Hard Shell all regular sizes ea. Tee Shell - all regular sizes Once the HeatSeal pipes are connected, this casing provides additional insulation and seals the outer jacket. The set comes with stone wool, a ready to use bitumen rubber kit, stainless steels bolts and an instruction leaflet. For use with all pipe sizes except " single HeatSeal Tee Shell all regular sizes ea. 60

63 Introduction MECHANICAL ROOM IN A BOX Making the Complex Simple HeatLink has found a way to make the complex more simple. With the Mechanical Room in a Box, some of the most common components of a radiant hydronic installation (mainly the wiring, pumps, and mixing valves), are installed on a panel with a plug, and boxed with a steel cover. This prewired, pre-fabricated, pre-engineered box is a time and money saving way to add control and consistency to an installation. lug it in, and presto you ve got play! Features Versatile solutions for simple or complex hydronic heating applications. re-fabricated, pre-engineered, pre-wired pre-cise! High quality, reliable and standardized construction. Modular approach for ease of installation. Appliance-like protective steel cover; tamper-resistant. Closed hydronic systems can be extensively zoned. Solar energy sources can be seamlessly added. When properly piped, there is less component cycling and more silence. Mechanical Room in a Box Advantages re-engineered solutions reduce design and quotation time. Reliable (ETL listed, UL 508, CSA standard), exceeds highest quality standards, with multiple test procedures for electrical and mechanical system components. Eliminate on-site design and reduced risk of on-site errors. Known cost; fewer surprises. Reduced installation times; time is money! Trouble-free start-ups every time! Fewer call-backs. Compact and aesthetically pleasing. Easily serviced and replaceable. Covered by a single warranty. 6

64 System anel Selection Mechanical Room in a Box anel Stk# Small House, Garage, Apartments TM TM TM070Z 6 70 TM085D Both TM200DT Both HE opt HE opt HE opt TWH rimary only TWH070S rimary only TWH070XS rimary only WH Large House CD * * * CD CD opt CD CD opt CD220M CD220M opt CD250M CD250M opt CD0R 72 0 opt CD0R Commercial SSM00 Series 7 TSM00 Series 74 SS00 Series to 2 SST00 Series 76 7 to 04 opt opt ZM ZM ZM ZM ZM Snow Melting SM400D SM SM SM SM Swimming ool / Hot Tub S M S M Solar SOL age # For use in open system For use in closed system Nominal Output (MBH) -way Mixing Valve Thermostatic Head Reset Mixing Heat Exchanger DHW riority Distribution Header Distribution Manifold DHW Branch & ump High Temp Branch High Temp ump 24hr Timer for otable Applications urge Timer Bypass Function For use with Tankless Water Heater Open System Zoning Auxiliary Dry Contacts for Heat Source Auxiliary Dry Contacts for DHW ump Check Valve * CD200 panel branch and pump can be used for either DHW or high temp, but not both 62

65 TM -Way Mixing anels TM040 TM 40/70 MBH -Way Mixing anels Stk# TM040 & TM070 The TM -Way Mixing anel s primary application is as a single zone mixing device where there are no flow requirements in the primary loop. Intended to be used with DHW tanks as a heat source, the pump is activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. At this time, a DHW priority option for these panels is not available. When the panel receives a call for heat, the pump is activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. When not used with a DHW tank as a heat source, secondary zoning downstream of the panel is possible. TM040 TM 40 MBH Mixing anel ea. TM070 TM 70 MBH Mixing anel ea. Mechanical Room in a Box TM 70 MBH -Way Mixing anel with Zoning Stk# TM070Z The TM -Way Mixing anel s primary application is as a multizone mixing device where there are no flow requirements in the primary loop. Intended to be used with DHW tanks as a heat source, the pump is activated, and actuators (sold separately) are opened once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. The power box has thermostat inputs and actuator outputs for up to four zones (two actuators per zone). At this time, a DHW priority option for these panels is not available. When the panel receives a call for heat, the pump is activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. When used with a DHW tank as a heat source, secondary zoning downstream of the panel is possible (subject to local codes). New! TM070Z TM 70 MBH Mixing anel with Zoning ea. 6

66 TM -Way Mixing anels TM 85 MBH Dual ump Mixing anel Stk# TM085D The TM -Way Mixing anel s primary application is as a single zone mixing device where there are no flow requirements in the primary loop. Intended to be used with DHW tanks as a heat source, the pump is activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. At this time, a DHW priority option for these panels is not available. When the panel receives a call for heat, the pump is activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. When not used with a DHW tank as a heat source, secondary zoning downstream of the panel is possible. The TM085D not only allows for higher output, but it is also a 2-zone panel. So even with a DHW heat source, you can now have two radiant floor zones. Mechanical Room in a Box TM085D TM 85 MBH Dual ump Mixing anel ea. TM 200 MBH 2-Temperature Mixing anel Stk# TM200DT The TM -Way Mixing anel s primary application is as a single zone mixing device where there are no flow requirements in the primary loop. Intended to be used with DHW tanks as a heat source, the pump is activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. At this time, a DHW priority option for these panels is not available. When the panel receives a call for heat, the pump is activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. When not used with a DHW tank as a heat source, secondary zoning downstream of the panel is possible. The TM200DT is a dual temperature panel. The low temperature output is the same as the TM070, but it also has a high temperature pump, for secondary high temperature applications such a as fan coil or baseboard. TM200DT TM 200 MBH 2 Temperature anel ea. 64

67 HE Isolation Heat Exchanger anels HE025 HE Isolation Heat Exchanger anels Stk# HE025 & HE080 The main application of the HE Isolation Heat Exchanger anel is to provide single wall isolation between a DHW tank and a heating system. While other applications are possible, it is important to note that this panel is not a temperature control device. The secondary water temperature is wholly dependent on the temperature of the primary supply water. When the panel receives a call for heat, it activates both primary and secondary pumps. The primary pump is also activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping or heat exchanger is not stagnant. The panel is pre-wired to work with the HES DHW priority switch (see below) which is mounted outside the panel. New! HE025 HE 25 MBH Isolation Heat Exchanger anel ea. HE080 HE 80 MBH Isolation Heat Exchanger anel ea. Mechanical Room in a Box Flow Indicator Assembly for DHW riority Stk# HES For use with the HE series panels. When using the HES priority switch, a flow sensor is installed in the DHW supply to the house downstream from the branch to the HE panel. When the HES detects water flow, it will turn off the primary pump in the HE panel, until such time that the DHW flow to the house falls below ~0.7 US gpm. HES Flow Indicator Assembly for Domestic Hot Water riority ea. 65

68 HE Isolation Heat Exchanger anels HE 95 BTU Isolation Heat Exchanger anel Stk# HE095 The main application of the HE Isolation Heat Exchanger anel is to provide single wall isolation between a DHW tank and a heating system. While other applications are possible, it is important to note that this panel is not a temperature control device. The secondary water temperature is wholly dependent on the temperature of the primary supply water. The HE095 is designed for applications where there is an extremely high flow resistance in the heat source. When the panel receives a call for heat, it activates both primary and secondary pumps. The primary pump is also activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping or heat exchanger is not stagnant. The panel is pre-wired to work with the HES DHW priority switch (see previous page) which can be mounted inside the panel. Mechanical Room in a Box New! HE095 HE 95 MBH Isolation Heat Exchanger anel ea. 66

69 TWH Tankless Water Heater anels TWH 70 MBH Tankless Water Heater Mixing anel Stk# TWH070 The TWH Tankless Water Heater Mixing anel s primary application is as a single zone mixing device for tankless DHW heaters. Both the primary and secondary pumps are activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. When a panel receives a call for heat, both pumps are activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. TWH070 TWH 70 MBH Tankless Water Heater Mixing anel ea. Mechanical Room in a Box 67

70 TWH Tankless Water Heater anels TWH 70 MBH Tankless Water Heater Mixing anels with DHW riority Stk# TWH070S & TWH070XS The TWH Tankless Water Heater Mixing anel s primary application is as a single zone mixing device for tankless DHW heaters. Both the primary and secondary pumps are activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. When the panel receives a call for heat, both pumps are activated, and the thermostatic control head in the -way mixing valve will automatically regulate the water temperature in the secondary circuit. The TWH070XS is designed for applications where there is an extremely high flow resistance in the heat source. Both the TWH070S and the TWH070XS have a flow activated DHW priority switch that turns off the primary pump when there is flow in the regular DHW line TWH070S TWH070XS Mechanical Room in a Box TWH070S TWH 70 MBH Tankless Water Heater Mixing anel with DHW riority ea. TWH070XS TWH 70 MBH High Head Tankless Water Heater Mixing anel with DHW riority ea. 68

71 CD 2-Temperature Combi DHW anels WH 0 MBH Water Heater ump anel with DHW riority Stk# WH0 The WH Water Heater ump anel s primary application is as a flow activated DHW priority switched pump. Intended to be used with DHW tanks as a heat source, the pump is activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping is not stagnant. The flow activated DHW priority switch turns off the primary pump when there is flow in the regular DHW line. WH0 WH Water Heater ump anel with DHW riority ea. CD 200 MBH 2-Temperature System anel Stk# CD200 Mechanical Room in a Box The CD200 Combi anel operates as a high/low temperature distribution center, with a boiler (or other non-dhw appliance) as a heat source. The CD200 has one high temperature branch that can be used for an indirect-fired DHW tank (with priority), or a high temperature heating application such as fan coils or baseboards. The thermostatic control head in the -way mixing valve will automatically regulate the water temperature in secondary circuit. CD200 CD 200 MBH 2 Temperature System anel with umps ea. 69

72 CD 2-Temperature Combi DHW anels CD MBH 2-Temperature Combi DHW System anels Stk# CD220 & CD250 The CD220 and 250 Combi anels operate as high/low temperature distribution centers, with a boiler (or other non-dhw appliance) as a heat source. The CD220 and 250 each have two high temperature branches, one for the indirect-fired DHW tank (with priority) and one for the high temperature heating application. The thermostatic control head in the -way mixing valve will automatically regulate the water temperature in secondary circuit. Mechanical Room in a Box CD220 CD250 New! New! CD220 CD 220 MBH 2 Temperature Combi DHW System anel with 4 umps ea. CD220 CD 220 MBH 2 Temperature Combi DHW System anel with umps ea. CD250 CD 250 MBH 2 Temperature Combi DHW System anel with 4 umps ea. CD250 CD 250 MBH 2 Temperature Combi DHW System anel with umps ea. 70

73 CD 2-Temperature Combi DHW anels CD MBH 2-Temperature System anels with Low Temp Header Stk# CD220M & CD250M The CD220M and 250M Combi anels operate as high/low temperature distribution centers, with a boiler (or other non-dhw appliance) as a heat source. The CD220M and 250M each have two high temperature branches, one for the indirect-fired DHW tank (with priority) and one for the high temperature heating application. The thermostatic control head in the -way mixing valve will automatically regulate the water temperature in secondary circuit. In addition, the CD 220M and 250M include a low temperature distribution header. Mechanical Room in a Box CD220M CD250M New! New! CD220M CD 220 MBH 2 Temperature Combi DHW System anel with 4 umps and Low Temp Manifold ea. CD 220 MBH 2 Temperature Combi DHW CD220M System anel with umps and Low Temp ea. Manifold CD 250 MBH 2 Temperature Combi DHW CD250M System anel with 4 umps and Low Temp ea. Manifold CD 250 MBH 2 Temperature Combi DHW CD250M System anel with umps and Low Temp ea. Manifold CD Actuator for Distribution Header Stk# CDACT Includes an actuator, two 4 washers, and two 4 MBS x 4 FT adapters to enable control of one additional zone on the distribution header. CDACT CD Actuator for Distribution Header ea. 7

74 CD 2-Temperature Combi DHW anels CD 0 MBH 2-Temperature System anels with Outdoor Reset Stk# CD0R & CD0R4 The CD0R Combi anels operate as high/low temperature distribution centers, with a boiler (or other non-dhw appliance) as a heat source. The CD0R panels each have two high temperature branches, one for the indirect-fired DHW tank (with priority) and one for the high temperature heating application. The #55 Compact Mixing Control with the -way mixing valve and actuator will automatically regulate the water temperature in secondary circuit. Mechanical Room in a Box CD0R4 New! New! CD 0 MBH 2 Temperature Combi DHW CD0R System anel with umps and Outdoor ea. Reset CD 0 MBH 2 Temperature Combi DHW CD0R4 System anel with 4 umps and Outdoor ea. Reset 72

75 SSM - Stainless Steel Manifold anels SSM Stainless Steel Manifold anels SSM Series The Stainless Steel Manifold anel allows easy access to the pre-mounted manifold through its coin locking (#7902 key locks optional, field installed) removable door. Frame and door enable a structural flush seal. Space is available for mounting a StatLink module above the manifold. Available in 4, 6, 8, and 0 loop configurations. Satin coated steel cover is ready to paint without priming. Comes with one loop closed and plugged. Openings for mains piping on left and right sides. Electrical wiring openings on top & sides. Depth allows for mounting a manifold in a 2 4 wall. Mechanical Room in a Box SSM06R SSM04R SSM Recessed 4 Loop Stainless Steel Manifold anel ea. SSM06R SSM Recessed 6 Loop Stainless Steel Manifold anel ea. SSM08R SSM Recessed 8 Loop Stainless Steel Manifold anel ea. SSM0R SSM Recessed 0 Loop Stainless Steel Manifold anel ea. 7

76 TSM - TwistSeal Mini Multiport Manifold anels TSM TwistSeal Mini Multiport Manifold anels TSM Series The TwistSeal Mini Multiport Manifold anel allows easy access to the pre-mounted manifold through its coin locking (#7902 key locks optional, field installed) removable door. Frame and door enable a structural flush seal. Space is available for mounting a StatLink module above the manifold. Available in 4, 6, 8, and 0 loop configurations. Satin coated steel cover is ready to paint without priming. Comes with one loop closed and plugged. Openings for mains piping on left and right sides. Electrical wiring openings on top & sides. Depth allows for mounting a manifold in a 2 4 wall. Mechanical Room in a Box TSM06R TSM04R TSM Recessed 4 Loop TwistSeal Mini Multiport Manifold anel ea. TSM06R TSM Recessed 6 Loop TwistSeal Mini Multiport Manifold anel ea. TSM08R TSM Recessed 8 Loop TwistSeal Mini Multiport Manifold anel ea. TSM0R TSM Recessed 0 Loop TwistSeal Mini Multiport Manifold anel ea. 74

77 SS - Stainless Steel Manifold ump anels SS - Stainless Steel Manifold ump anels SS Series The Stainless Steel Manifold ump anel includes a recessed housing with coin lock (#7902 key locks optional, field installed), stainless steel manifold with flow meters, automatic air vent, and pre-wired system pump & relay. Space is available for mounting a StatLink module above the manifold. Available in 4, 6, 8, and 0 loop configurations. Satin coated steel housing is ready to paint without priming. Comes with one loop closed and plugged. Electrical wiring openings on top & sides. Depth allows for mounting a manifold in a 2 6 wall. Custom configurations are available. lease call for details. Mechanical Room in a Box SS06RS SST06RL with SSAB SS04RS SS Recessed 4 Loop Stainless Steel Manifold Small ump anel ea. SS04RL SS Recessed 4 Loop Stainless Steel Manifold Large ump anel ea. SS06RS SS Recessed 6 Loop Stainless Steel Manifold Small ump anel ea. SS06RL SS Recessed 6 Loop Stainless Steel Manifold Large ump anel ea. SS08RS SS Recessed 8 Loop Stainless Steel Manifold Small ump anel ea. SS08RL SS Recessed 8 Loop Stainless Steel Manifold Large ump anel ea. SS0RS SS Recessed 0 Loop Stainless Steel Manifold Small ump anel ea. SS0RL SS Recessed 0 Loop Stainless Steel Manifold Large ump anel ea. SSAB Optional ressure Bypass Installed in SS or SST anel ea. 75

78 SST - Stainless Steel Manifold Mixing anels SST - Stainless Steel Manifold Mixing anels SST Series The Stainless Steel Manifold Mixing anel includes a recessed housing with coin lock (#7902 key locks optional, field installed), stainless steel manifold, automatic air vent, -way mixing valve, and prewired system pump. Space is available for mounting a StatLink module above the manifold. Available in 4, 6, 8, and 0 loop configurations. Satin coated steel housing is ready to paint without priming. Comes with one loop closed and plugged. Electrical wiring openings on top & sides. Depth allows for mounting a manifold in a 2 6 wall. Custom configurations are available. lease call for details. Mechanical Room in a Box SST06RS with SSATH SST06RL with SSADDC SST04RS SST Recessed 4 Loop Stainless Steel Manifold Small Mixing anel ea. SST04RL SST Recessed 4 Loop Stainless Steel Manifold Large Mixing anel ea. SST06RS SST Recessed 6 Loop Stainless Steel Manifold Small Mixing anel ea. SST06RL SST Recessed 6 Loop Stainless Steel Manifold Large Mixing anel ea. SST08RS SST Recessed 8 Loop Stainless Steel Manifold Small Mixing anel ea. SST08RL SST Recessed 8 Loop Stainless Steel Manifold Large Mixing anel ea. SST0RS SST Recessed 0 Loop Stainless Steel Manifold Small Mixing anel ea. SST0RL SST Recessed 0 Loop Stainless Steel Manifold Large Mixing anel ea. 76 SSADDC 562 DDC Actuator Installed on Mixing Valve in SST anel ea. SSAB Optional ressure Bypass Installed in SS or SST anel ea. SSATH Thermostatic Head Installed in SST anel ea.

79 ZM Multi-branch Zone Mixing anels ZM 6-0 Branch Zone Mixing anels ZM Series The multi-branch unit provides 6 to4 zones/branches of mixed water, each having a capacity of up to.5 GM ( 4" zone valves are provided), with the combined total output flow not exceeding 5 GM. A slow-acting zone valve, eliminating the water hammer effect commonly experienced with quick-acting valves, controls flow to each zone. Though the panel is not supplied with thermostats (but is suitable for use with HeatLink Thermostats), it has a standard factory wired panel terminal strip where a thermostat may be field wired. A pressure bypass valve provides a minimum flow through the panel when there is a limited demand for heat. Mixed water is provided by a -way valve which is controlled by an outdoor reset control. ZM00 rimary Return rimary Supply Mechanical Room in a Box Secondary Returns Secondary Supplies ZM006 ZM 6 Branch Trunk Manifold Mixing anel ea. ZM008 ZM 8 Branch Trunk Manifold Mixing anel ea. ZM00 ZM 0 Branch Trunk Manifold Mixing anel ea. ZM02 ZM 2 Branch Trunk Manifold Mixing anel ea. ZM04 ZM 4 Branch Trunk Manifold Mixing anel ea. 77

80 SM Snow Melt anels SM 400 MBH Snow Melt anel without Heat Exchangers Stk# SM400D The SM400D Snow Melt anel is a central operations center for a fully automatic snow melt system. The SM400D does not have an isolation heat exchanger and is intended for snow melt systems with a dedicated heat source (e.g. a boiler or other non-dhw appliance). Housing the snow melt pump, mixing valve, and controls, it supplies the snow melt pad with the glycol mixture from the heat source. rimary Return rimary Supply Mechanical Room in a Box Secondary Return Secondary Supply SM MBH Snow Melt anels with Heat Exchangers SM000 Series The SM Snow Melt anels are central operations centers for fully automatic snow melt systems requiring isolation. Housing the snow melt pump, mixing valve, and controls, it also contains brazed plate heat exchangers to isolate the snow melt system glycol mixture from the heating system water. On the snow melt side, this panel incorporates an air eliminator, a pressure relief valve, and taps for an expansion tank and make up water. SM425 rimary Return rimary Supply Secondary Return Secondary Supply SM05 SM 05 MBH Snow Melt anel with 2 20 late Heat Exchangers ea. SM250 SM 250 MBH Snow Melt anel with 20 late Heat Exchangers ea. SM5 SM 5 MBH Snow Melt anel with 4 20 late Heat Exchangers ea. SM425 SM 425 MBH Snow Melt anel with 4 0 late Heat Exchangers ea. SM400D SM 400 MBH Snow Melt anel (no heat exchangers) ea. 78

81 S - ool/spa anels S MBH ool/spa anels with Marine late Heat Exchangers S000 Series The S ool/spa anel s primary application is to provide heat exchanger isolation from the boiler (or other non-dhw appliance heat sources). The S panels use marine grade heat exchangers that will withstand aggressive pool water. S500 rimary Return rimary Supply Secondary Return Secondary Supply S250 S 250 MBH ool/spa anel with Single Marine Heat Exchanger ea. S500 S 500 MBH ool/spa anel with Dual Marine Heat Exchanger ea. Mechanical Room in a Box 79

82 Solar Heat Exchanger anel SOL 80 MBH Solar Heat Exchanger anel Stk# SOL080 The SOL080 Heat Exchanger anel creates an interface between the solar collectors and the system tanks. The anel integrates all of the control components of a solar system into an attractive compact appliance. Features include a heat exchanger to isolate the glycol in the solar collector circuit from the domestic water, and separate pumps for each circuit. The secondary pump is activated once every 24 hours, for 5 minutes, to ensure that potable water in the piping or heat exchanger is not stagnant. Mechanical Room in a Box SOL080 SOL 80 MBH Solar Heat Exchanger anel ea. 80

83 The HeatLink otable Water System System Source The strength of every good system is found in its source. The HeatLink otable Water System features the urelink EX-a Tubing and the EasyFit Manifold, and is capped off with the unique Stainless Steel ress Sleeve and a variety of modular components. The result is a strong system delivering an abundant stream of pure water. Flexible Tubing Meets Stiff Standards To make one of the most flexible EX-a tubing on the market, we had to be inflexible with the particulars. The tubing had to meet the standards for purity and durability, and be compatible with our components we did it! Factor in the following features, and you ve got some awesome tubing. Installer friendly available in long coils (or straight-lengths as risers), the tubing bends when needed, with minimal need for couplings and fittings. No need for solvents or soldering. Lightweight for transport and easy to handle. Building friendly unlike metal tubing, EX-a tubing does not suffer from: corrosion, electrolysis, filming, mineral build-up, and water velocity wear. Earth friendly energy efficient with reduced heat loss and good thermal memory. Water efficient, as the flexible tubing means less tubing, and hence, shorter delivery time for hot water. Cost friendly lower installation costs than metal plumbing systems. This can reduce energy and water use by quick delivery of water to fixtures. eople friendly non-toxic, no hot /cold water surges, quiet (no water hammer noise). HeatLink Group Inc. is a worldwide leading supplier of EX-a tubing, radiant heating and cooling systems, and control panels for residential and commercial buildings. HeatLink s reputation has been built on more than 25 years of experience, innovation and leadership, integrating a complete system approach to its potable water products and heating manufacturing operation. otable Water Systems 8

84 ure Link EX-a Tubing EX Benefits HeatLink uses only crosslinked polyethylene tubing. Known as EX, crosslinked polyethylene offers distinct advantages over both metal piping materials and other plastic alternatives. Our tubing is virtually maintenance free. It is corrosion resistant, flexible, and remarkably clean. Long used worldwide, EX has an outstanding and unblemished track record of quality performance. EX s crosslinked molecular structure offers toughness and lasting durability. Our crosslinked polyethylene tubing withstands temperatures ranging from below freezing to above the boiling point. Because it is pliable, a section of 2" tubing can be bent into a " (77 mm) radius at 68 F (20 C) without affecting tubing integrity. The material is highly crush resistant and can be submerged in concrete or earth without any damage. urelink Advantages Nontoxic - free of harmful lead Flexible - bends easily making installations quicker Resists corrosive water and scaling Fewer fittings Quiet - no water hammer noise Equalized pressure drops, minimize hot or cold surges Can easily be repaired if tubing is kinked Durable/long life Labor costs are significantly reduced Light weight Discreet red/blue identification is an advantage where EX tubing is exposed (e.g. water closet connections) Only need to stock two colors, not three Chlorine resistant Freeze and chemical resistant Cold rolled for easier installations UV stabilized for up to 2 months exposure to sunlight Low friction losses

85 urelink otable Water EX-a Tubing urelink lus Blue Stripe EX-a Tubing Series High molecular crosslinked polyethylene (EX) with minimum bending radius of 6 the diameter at 68 F (20 C). Maximum operating temperature psi (82 7 bar). Blue printing on 2 sides for identification of cold water lines. Meets or exceeds ASTM F876/F877/F202, CSA B7.5, cnsfus-pw, NSF/ANSI-6, NSF/ANSI-4, Annex G, ICC, ULC S02.2 ( 2" to "), IAMO UC ( 2"), I TR-4. The urelink lus EX-a tubing may also be used with fittings that are compliant with ASTM F807/F960/F2080/F2098/ F259 standards. Minimum bending 68 F (20 C) for: 2" = " (77 mm) 4" = 4-2" (5 mm) " = 6" (5 mm) - 4" = 7-2" (9 mm) Stk# Description kg Qty Carton Skid Qty Unit Disc. List rice / Unit " 00ft urelink LUS Blue UV Stabilized EX-a excube 6 48 coil " 00ft urelink LUS Blue UV Stabilized EX-a Tubing 2 coil " 500ft urelink LUS Blue UV Stabilized EX-a Tubing 24 coil " 000ft urelink LUS Blue UV Stabilized EX-a Tubing 4 coil " 00ft urelink LUS Blue UV Stabilized EX-a excube 48 coil " 00ft urelink LUS Blue UV Stabilized EX-a Tubing 4 coil " 500ft urelink LUS Blue UV Stabilized EX-a Tubing 9 coil " 000ft urelink LUS Blue UV Stabilized EX-a Tubing 5 coil 2028 " 00ft urelink LUS Blue UV Stabilized EX-a Tubing 2 coil 2028 " 00ft urelink LUS Blue UV Stabilized EX-a Tubing 9 coil New! 205-4" 00ft urelink LUS Blue UV Stabilized EX-a Tubing 4 coil otable Water Systems Stk# Description kg Qty Master Carton Bag Qty Unit Disc. List rice / Unit " 20 20ft urelink LUS Blue UV Stabilized EX-a Tubing 20 bundle " 0 20ft urelink LUS Blue UV Stabilized EX-a Tubing 20 bundle " 5 20ft urelink LUS Blue UV Stabilized EX-a Tubing 20 bundle New! " 5 20ft urelink LUS Blue UV Stabilized EX-a Tubing bundle 8

86 urelink otable Water EX-a Tubing urelink lus Red Stripe EX-a Tubing 2000 Series High molecular crosslinked polyethylene (EX) with minimum bending radius of 6 the diameter at 68 F (20 C). Maximum operating temperature psi (82 7 bar). Red printing on 2 sides for identification of hot water lines. Meets or exceeds ASTM F876/F877/F202, CSA B7.5, cnsfus-pw, NSF/ANSI-6, NSF/ANSI-4, Annex G, ICC, ULC S02.2 ( 2" to "), IAMO UC ( 2"), I TR-4. The urelink lus EX-a tubing may also be used with fittings that are compliant with ASTM F807/F960/F2080/F2098/ F259 standards. Minimum bending 68 F (20 C) for: 2" = " (77 mm) 4" = 4-2" (5 mm) " = 6" (5 mm) - 4" = 7-2" (9 mm) otable Water Systems Stk# Description kg Qty Carton Skid Qty Unit Disc. List rice / Unit 205 2" 00ft urelink LUS Red UV Stabilized EX-a excube 6 48 coil 205 2" 00ft urelink LUS Red UV Stabilized EX-a Tubing 2 coil New! " 500ft urelink LUS Red UV Stabilized EX-a Tubing 24 coil " 000ft urelink LUS Red UV Stabilized EX-a Tubing 4 coil 222 4" 00ft urelink LUS Red UV Stabilized EX-a excube 48 coil 222 New! 2522 New! New! 25 4" 00ft urelink LUS Red UV Stabilized EX-a Tubing 4" 500ft urelink LUS Red UV Stabilized EX-a Tubing 4" 000ft urelink LUS Red UV Stabilized EX-a Tubing " 00ft urelink LUS Red UV Stabilized EX-a Tubing " 00ft urelink LUS Red UV Stabilized EX-a Tubing - 4" 00ft urelink LUS Red UV Stabilized EX-a Tubing 4 coil 9 coil 5 coil 2 coil 9 coil 4 coil Stk# Description kg Qty Master Carton Bag Qty Unit Disc. List rice / Unit " 20 20ft urelink LUS Red UV Stabilized EX-a Tubing 20 bundle " 0 20ft urelink LUS Red UV Stabilized EX-a Tubing 20 bundle 2228 " 5 20ft urelink LUS Red UV Stabilized EX-a Tubing 20 bundle New! 225-4" 5 20ft urelink LUS Red UV Stabilized EX-a Tubing bundle 84

87 ure Link ipe-in-ipe Never again deal with the hassle of trying to pull tubing through conduits. Our pliable EX-a tubing is available in a high impact resistant sheath. 4" urelink ipe-in-ipe 2" urelink ipe-in-ipe Basin Feed plumbing fixtures in buildings of all sizes. Allows for insertion and withdrawal of inner EX-a tubing for perpetual access. Toilet Bathtub 2-ort EasyFit Tee # ort EasyFit Tee #2200

88 urelink ipe-in-ipe urelink lus ipe-in-ipe Sheathed Series EX-a carrier tubing specified on previous pages. The flexible, impact resistant E sheath designed as a raceway for electrical installations provides mechanical and UV protection to the EX-a carrier tubing. The sheath allows for easy replacement of the EX-a carrier tubing if needed. Red and Blue colored sheaths make for easy identification of hot and cold water lines. Meets or exceeds ASTM F876/F877/F202, CSA B7.5, cnsfus-pw, NSF/ANSI-6, NSF/ANSI-4, Annex G, ICC, ULC S02.2 ( 2" to "), IAMO UC ( 2"), I TR-4. The urelink lus EX-a tubing may also be used with fittings that are compliant with ASTM F807/F960/F2080/F2098/ F259 standards. Minimum bending 68 F (20 C) for: 2" = " (77 mm) 4" = 4-2" (5 mm) " = 6" (5 mm) E sheath is rated to UL94HB Tests for Flammability of lastic Materials. Corrogated sheath outside diameter for: 2" = " (25 mm) 4" = - 5 6" (4 mm) " = - 2" (7 mm) otable Water Systems Nov. st Nov. st Nov. st Nov. st Stk# Description kg Qty Carton Skid Qty Unit Disc. List rice / Unit 9205bs 2" 00ft ipe-in-ipe Blue Sheath 27 coil 9205rs 2" 00ft ipe-in-ipe Red Sheath 27 coil 9205bs 2" 00ft ipe-in-ipe Blue Sheath coil 9205rs 2" 00ft ipe-in-ipe Red Sheath coil 9222bs 4" 00ft ipe-in-ipe Blue Sheath 2 20 coil 9222rs 4" 00ft ipe-in-ipe Red Sheath 2 20 coil 9222bs 4" 00ft ipe-in-ipe Blue Sheath coil 9222rs 4" 00ft ipe-in-ipe Red Sheath coil 9228bs " 00ft ipe-in-ipe Blue Sheath coil 9228rs " 00ft ipe-in-ipe Red Sheath coil 86

89 urelink Reclaim Water EX Tubing urelink Reclaim Water EX-a Tubing 9000 Series As regulated by NSF-4 standards, this tubing is purple throughout to warn people that the water is not drinkable. Use reclaim water EX tubing to transport reclaimed, gray, or rain water for all of your non-potable applications: flushing toilets, water plants, drip irrigation. High molecular crosslinked polyethylene (EX-a) with minimum bending radius of 6 the diameter at 68 F (20 C). Maximum operating temperature psi (82 7 bar). Manufactured to ASTM F-876/F-877 & CSA B7.5 and listed by cnsfus-rw. Minimum bending 68 F (20 C) for: 2" = " (77 mm) 4" = 4-2" (5 mm) " = 6" (5 mm) Stk# Description kg Qty Carton Skid Qty Unit Disc. List rice / Unit 905 2" 00ft urple urelink Reclaim UV- Stabilized EX-a Tubing 6 48 coil 905 2" 00ft urple urelink Reclaim UV- Stabilized EX-a Tubing 2 coil 922 4" 00ft urple urelink Reclaim UV- Stabilized EX-a Tubing 4 coil 928 " 00ft urple urelink Reclaim UV- Stabilized EX-a Tubing 2 coil urelink Reclaim ipe-in-ipe Sheathed Series EX-a carrier tubing specified above. The flexible, impact resistant E sheath designed as a raceway for electrical installations provides mechanical and UV protection to the EX-a carrier tubing. The sheath allows for easy replacement of the EX-a carrier tubing if needed. urple colored sheath matches EX for identification of non-potable lines. Minimum bending 68 F (20 C) for: 2" = " (77 mm) 4" = 4-2" (5 mm) " = 6" (5 mm) E sheath is rated to UL94HB Tests for Flammability of lastic Materials. Corrogated sheath outside diameter for: 2" = " (25 mm) 4" = - 5 6" (4 mm) " = - 2" (7 mm) otable Water Systems Nov. st Nov. st Stk# Description kg Qty Carton Skid Qty Unit Disc. List rice / Unit 9205ps 2" 00ft ipe-in-ipe urple Sheath 27 coil 9205ps 2" 00ft ipe-in-ipe urple Sheath coil 9222ps 4" 00ft ipe-in-ipe urple Sheath 2 20 coil 9222ps 4" 00ft ipe-in-ipe urple Sheath coil 9228ps " 00ft ipe-in-ipe urple Sheath coil 87

90 EasyFit Manifold It s as EasyFit as A B C 2" EX-a to fi xtures Advanced Manifold Tee Ultimate in speed of installation HeatLink technology Molded fitting connections Modular design EasyFit tool-less connection system 2" EX-a to fi xtures Better by Design Simple Fast Flexible Cost effective Choice of iping Method Modified home run Home run Minimal tools required 2" EX-a to outside spigots

91 EasyFit Manifold Compression Stop Tee Stk# 2200 The potable water module complete with shut-off. Order shut-off cap (#2280 & #228) and EX insert style, tubing to manifold connectors (#2000 series) separately. There are 4 shrink-wrapped packages of 5 modules per box Compression Stop Tee 20 ea. EasyFit 2-ort Tee Stk# A 2-port tee with 2" EasyFit connections. Includes 2 nuts EasyFit 2-ort Tee 50 ea. EasyFit -ort Tee Stk# 2200 A -port tee with 2" EasyFit connections. Includes nuts EasyFit -ort Tee 50 ea. otable Water Systems Mounting Bracket Stk# 222 lastic mounting brackets which allow easy snap-on mounting of manifolds. 222 Single Mounting Bracket 0 ea. 89

92 EasyFit Manifold Components Red & Blue Shut-off Caps Stk# 2280, 228 Red (#2280) and blue (#228) colored caps for use with otable Module Tee with Compression Stop (#2200). No tools required Red Shut-off Cap 250 ea. 228 Blue Shut-off Cap 250 ea. 2" EasyFit Supply End Connection Stk# 229 O-ring sealing end piece with 2" EasyFit connection. Comes with o-ring " EasyFit Supply End Connection ea. 4" FT Supply End Connection Stk# 229 O-ring sealing end piece with 4" FT brass insert. Comes with o-ring. otable Water Systems 229 TwistSeal Mini (40 mm) 4" FT Supply End Connection (c/w o-ring) ea. 4" EasyFit Supply End Connection Stk# 2294 O-ring sealing end piece with 4" EasyFit connection. Comes with o-ring " EasyFit Supply End Connection ea. " MT Supply End Connection with Closed End Cap Stk# 2296 O-ring sealing end piece with " MT brass insert. Comes with o-ring TwistSeal Mini (40 mm) " MT Supply End Connection ea. 90

93 EasyFit Manifold Components Closed End Cap Stk# 2299 O-ring sealing end piece EasyFit Manifold Closed End Cap ea. 4" EasyFit Run End Connection Stk# 2295 O-ring sealing end piece with 4" EasyFit connection. Comes with o-ring " EasyFit Run End Connection ea. EasyFit 2" Outlet Cap with o-ring Stk# 2055 lastic cap with o-ring to seal unused outlet of #22002 & # EasyFit 2" Outlet Cap with o-ring 0 ea. Tubing to Manifold Connectors 2000 Series lastic fitting is installed into the bottom of the manifold module and is held in place by the nut. The tubing is then pressed on to this fitting. SS press sleeves sold separately. For use with Compression Stop Tee # " EX Insert Manifold Connector 5 ea " EX Insert Manifold Connector with nut 5 ea. otable Water Systems 9

94 Copper Manifolds Closed End Copper Manifold Series " pipe run with to 0, 2" EX insert branches (2" O.C.). Closed one end and 4" brass EX insert on the other end. SS press sleeves sold separately. CSA listed ASTM B88 Type L copper trunk High temperature brazed joints CSA listed ASTM F877 brass EX insert branches Individually pressure tested " EX Branch, 4" EX Spin Closed Trunk Copper Manifold 0 ea " EX Branch, 4" EX Spin Closed Trunk Copper Manifold 0 ea " EX Branch, 4" EX Spin Closed Trunk Copper Manifold 0 ea " EX Branch, 4" EX Spin Closed Trunk Copper Manifold 0 ea " EX Branch, 4" EX Spin Closed Trunk Copper Manifold 0 ea " EX Branch, 4" EX Spin Closed Trunk Copper Manifold 0 ea " EX Branch, 4" EX Spin Closed Trunk Copper Manifold 0 ea " EX Branch, 4" EX Spin Closed Trunk Copper Manifold 0 ea. otable Water Systems Flow Through Copper Manifold Series " pipe run with to 6, 2" EX insert branches (2" O.C.). 4" brass EX insert on both ends. SS press sleeves sold separately. CSA listed ASTM B88 Type L copper trunk High temperature brazed joints CSA listed ASTM F877 brass EX insert branches Individually pressure tested " EX Branch, 4" EX 4" EX Trunk Copper Manifold 0 ea " EX Branch, 4" EX 4" EX Trunk Copper Manifold 0 ea " EX Branch, 4" EX 4" EX Trunk Copper Manifold 0 ea " EX Branch, 4" EX 4" EX Trunk Copper Manifold 0 ea. 92

95 Stainless Steel ress Sleeve Making a Lasting Impression ress Sleeve HeatLink otable Water Systems now offers a start-to-finish system capped off with the unique EX tubing watertight connection the stainless steel ress Sleeve. The ress Sleeve slides over the outer part of the EX-a tubing, before inserting the fitting. When the fitting is in place, the press tool secures the connection in one single press, evidenced by a smooth visible W depression ring on the sleeve's surface. No crimp gauge is required with a ress Sleeve, thus eliminating a step in the whole installation procedure. Once the pressing is complete, everything is set for the pressure test. The room for error is reduced, as the visible impression on the sleeve indicates readiness for the pressure test. non-pressed pressed HeatLink's ress Sleeve an impressive connection to have in any pressing situation. The SS ress Sleeve is tested to ASTM F877 and is NSF-pw listed. ress Tool Designed to create a watertight seal, the ress Sleeve Tool has a toggle action handle and is available in four sizes. Easy to load and simple to press, the pressed stainless steel sleeve provides a finished appearance on the transition from the end of the pipe to the insert fitting. HeatLink ress Tool Trade-U Concerned about the expanding size of your toolbox? Hand in your current crimp, SS clamp, or expansion tools, and trade-u to the HeatLink ress Tool. See your rep for details. (tool not to scale)

96 SS ress Sleeves & EX Insert Fittings Stainless Steel ress Sleeves Series ress sleeve with view hole " Stainless Steel ress Sleeve ea " Stainless Steel ress Sleeve ea " Stainless Steel ress Sleeve ea " Stainless Steel ress Sleeve 0 50 ea. EX Insert Couplings - Brass & Series Solid brass EX insert EX insert couplings. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " 2" EX Brass Coupling ea " 4" EX Brass Coupling ea " 2" EX Brass Coupling ea " " EX Brass Coupling ea. New! " 4" EX Brass Coupling ea. otable Water Systems No Lead EX Insert Couplings - No Lead Brass 29000NL & 29200NL Series Solid no lead brass (C6900-ecobrass) EX insert EX insert couplings. SS press sleeves sold separately. New! 2905NL - 4" - 4" EX No Lead Brass Coupling 5 80 ea. New! 2928NL - 4" " EX No Lead Brass Coupling ea. EX Insert Couplings - H 9000 Series High erformance olymer EX insert couplings. SS press sleeves sold separately " 2" EX H Coupling ea " 4" EX H Coupling ea " 2" EX H Coupling ea " " EX H Coupling ea " 4" EX H Coupling 5 00 ea. 94

97 H Fitting System The HeatLink High erformance olymer (H) fitting system is produced from a specific blend of engineered high performance polyphenylsulfone (SU) resins. When combined, these resins offer outstanding long-term performance and chemical resistance. The sulfone family of resins began to replace brass in the plumbing industry over 20 years ago, and in the course of time have exceeded the stringent demands of the potable and heating industries. O S O O O n Figure # General Chemical Structure of SU The HeatLink H fittings standout in the market place due to a unique combination of characteristics designed to deliver superior performance. Outstanding resistance to hot chlorinated water Superior long-term hydrostatic strength Excellent thermal stability High resistance to mineral acids, alkali, and salt solutions Higher resistance to polar solvents and stress cracking than traditional polysulfone Robust toughness and impact strength Exceptional hydrolytic stability Improved notch resistance

98 EX Insert Elbows EX Insert Elbows - Brass & Series Solid brass EX insert EX insert elbows. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " 2" EX Brass Elbow ea " 4" EX Brass Elbow ea " 2" EX Brass Elbow ea " " EX Brass Elbow 0 00 ea. No Lead EX Insert Elbows - No Lead Brass 28000NL & 28200NL Series Solid no lead brass (C6900-ecobrass) EX insert EX insert elbows. SS press sleeves sold separately. New! 2805NL - 4" - 4" EX No Lead Brass Elbow 5 20 ea. otable Water Systems EX Insert Elbows - H 8000 Series High erformance olymer EX insert elbows. SS press sleeves sold separately " 2" EX H Elbow ea " 4" EX H Elbow ea " 2" EX H Elbow ea " " EX H Elbow 0 50 ea. 96

99 EX Insert Threaded Elbows EX Insert MT Elbows - Brass Series Solid brass EX insert elbows. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " EX 8" MT Brass Dishwasher Elbow 25 ea. EX Insert MT Elbows - No Lead Brass Series Solid no lead brass (C6900-ecobrass) EX insert elbows. SS press sleeves sold separately. New! 2858NL " EX - 4" MT No Lead Brass Elbow 5 60 ea. New! 2855NL - 4" EX - 4" MT No Lead Brass Elbow 5 50 ea. EX Insert MT Elbows - H 8000 Series High erformance olymer EX insert elbows. SS press sleeves sold separately " EX 8" MT H Dishwasher Elbow ea " EX 2" MT H Elbow ea. otable Water Systems 97

100 EX Insert FT Adapters Drop Ear Elbows - Brass 2800 Series Solid brass EX insert FT drop ear elbow. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately. New! 282 2" EX 8" FT Drop Ear Brass Elbow 0 50 ea " EX 2" FT Drop Ear Brass Elbow 0 50 ea. No Lead Drop Ear Elbows - No Lead Brass 2800NL Series Solid no lead brass (C6900-ecobrass) /2" EX insert /2" FT drop ear elbow. SS press sleeves sold separately. New! New! 282NL 2" EX 8" FT Drop Ear No Lead Brass Elbow 0 80 ea. 2805NL 2" EX 2" FT Drop Ear No Lead Brass Elbow 0 60 ea. EX Insert FT Adapters - Brass Series otable Water Systems No Lead Solid brass EX insert FT adapters. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " EX 2" FT Brass Adapter ea " EX 4" FT Brass Adapter ea. New! " EX " FT Brass Adapter ea. EX Insert FT Adapters - No Lead Brass 27600NL Series Solid no lead brass (C6900-ecobrass) EX insert FT adapters. SS press sleeves sold separately. New! 27605NL 2" EX 2" FT No Lead Brass Adapter ea. New! 27622NL 4" EX 4" FT No Lead Brass Adapter ea. New! 27628NL " EX " FT No Lead Brass Adapter ea. New! 2765NL - 4" EX - 4" FT No Lead Brass Adapter 5 80 ea. 98

101 EX Insert Fixture Adapters EX Insert FT Swivel Adapters - H 7700 Series High erformance olymer EX insert FT swivel adapters. SS press sleeves sold separately " EX 2" FT Swivel H Adapter 25 ea " EX Ballcock/Closet FT Swivel H Adapter ea " EX 4" FT Swivel H Adapter ea. EX Insert FT Swivel Elbow Adapter - H Stk# 8605 High erformance olymer EX insert FT swivel elbow adapters. SS press sleeves sold separately " EX 2" FT Swivel H Elbow ea. 2" EX 8" O.D. Comp. Straight Lav. Tube Adapter - Brass Stk# 2575 Solid brass adapter for connecting faucets. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " EX 8" O.D. Brass Adapter 5 00 ea. otable Water Systems 99

102 EX Insert MT Adapters EX Insert MT Adapters - Brass Series Solid brass EX insert MT adapters. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " EX 2" MT Brass Adapter ea " EX 4" MT Brass Adapter ea " EX 4" MT Brass Adapter ea " EX " MT Brass Adapter ea " EX 4" MT Brass Adapter ea. No Lead EX Insert MT Adapters - No Lead Brass 27500NL Series Solid brass no lead (C6900-ecobrass) EX insert MT adapters. SS press sleeves sold separately. New! 27528NL " EX " MT No Lead Brass Adapter 0 50 ea. New! 27582NL " EX 4" MT No Lead Brass Adapter ea. New! 2755NL - 4" EX - 4" MT No Lead Brass Adapter 5 00 ea. New! 2758NL - 4" EX " MT No Lead Brass Adapter 5 00 ea. otable Water Systems EX Insert MT Adapters - H 7500 Series High erformance olymer EX insert MT adapters. SS press sleeves sold separately " EX 2" MT H Adapter ea " EX 4" MT H Adapter ea " EX 4" MT H Adapter ea " EX 2" MT H Adapter ea. 00

103 EX Insert Sweat Adapters EX Insert Sweat Adapters - Brass 2700 & Series Solid brass EX insert sweat adapters. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " EX 2" M/Sweat Brass Adapter ea " EX 2" F/Sweat Brass Adapter ea " EX 4" M/Sweat Brass Adapter ea " EX 4" F/Sweat Brass Adapter ea. New! " EX " F/Sweat Brass Adapter 0 00 ea " EX " M/Sweat Brass Adapter ( 4" F/ Sweat) 0 00 ea " EX " F/Sweat Brass Adapter 0 00 ea. No Lead EX Insert Sweat Adapters - No Lead Brass 2700NL & 27200NL Series Solid no lead brass (C6900-ecobrass) EX insert sweat adapters. SS press sleeves sold separately. New! 2705NL 2" EX 2" M/Sweat No Lead Brass Adapter ea. New! 27205NL 2" EX 2" F/Sweat No Lead Brass Adapter ea. New! 2722NL 4" EX 4" M/Sweat No Lead Brass Adapter ea. New! 27222NL 4" EX 4" F/Sweat No Lead Brass Adapter ea. New! 2728NL " EX " M/Sweat No Lead Brass Adapter ( 4" F/Sweat) ea. New! 27228NL " EX " F/Sweat No Lead Brass Adapter ea. New! 275NL - 4" EX - 4" M/Sweat No Lead Brass Adapter 5 20 ea. New! 2725NL - 4" EX - 4" F/Sweat No Lead Brass Adapter 5 20 ea. otable Water Systems 0

104 EX Insert Tees Branch EX Insert Tees - Brass Series Solid brass EX insert tees. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately. Run Run Stk# Description Description (run run branch) kg Qty Carton Qty Unit Disc. List rice / Unit " 2" 2" EX Brass Tee ea " 2" 4" EX Brass Tee ea " 4" 4" EX Brass Tee ea " 4" 2" EX Brass Tee ea " 2" 4" EX Brass Tee ea " 2" 2" EX Brass Tee ea " " " EX Brass Tee 0 00 ea " " 4" EX Brass Tee 5 00 ea " 4" 4" EX Brass Tee 5 00 ea " " 2" EX Brass Tee 0 00 ea. otable Water Systems Run No Lead Branch Run EX Insert Tees - No Lead Brass 26000NL Series Solid no lead brass (C6900-ecobrass) EX insert tees. SS press sleeves sold separately. Stk# Description Description (run run branch) kg Qty Carton Qty Unit Disc. List rice / Unit New! 26NL - 4" - 4" - 4" EX No Lead Brass Tee 5 80 ea. New! 268NL - 4" - 4" " EX No Lead Brass Tee 5 80 ea. New! 262NL - 4" - 4" 4" EX No Lead Brass Tee 5 80 ea. New! 2688NL - 4" " " EX No Lead Brass Tee 5 00 ea. New! 2622NL - 4" 4" 4" EX No Lead Brass Tee 5 00 ea. 02

105 EX Insert Tees & lugs Branch EX Insert Tees - H 6000 Series High erformance olymer EX insert tees. SS press sleeves sold separately. Run Run Stk# Description Description (run run branch) kg Qty Carton Qty Unit Disc. List rice / Unit " 2" 2" EX H Tee ea " 2" 4" EX H Tee ea " 4" 4" EX H Tee ea " 4" 2" EX H Tee ea " 2" 4" EX H Tee ea " 2" 2" EX H Tee ea " " " EX H Tee 0 00 ea " " 4" EX H Tee 5 00 ea " " 2" EX H Tee 0 50 ea. New! " 4" " EX H Tee 5 50 ea " 4" 4" EX H Tee 5 50 ea. New! 6828 " 4" " EX H Tee 5 00 ea. EX Insert lugs - Brass Series Solid brass EX insert plug. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " EX Brass lug ea " EX Brass lug ea " EX Brass lug ea. No Lead EX Insert lugs - No Lead Brass 25000NL Series Solid no lead brass (C6900-ecobrass) EX insert plug. SS press sleeves sold separately. otable Water Systems New! 2505NL - 4" EX No Lead Brass lug ea. EX Insert lugs - H 5000 Series High erformance olymer EX insert plugs. SS press sleeves sold separately " EX H lug ea " EX H lug ea " EX H lug ea. 0

106 Ball Valves Chrome lated Straight Ball Valve - Brass Stk #2505 2" EX barb 8" O.D. compression, plated straight ball valve. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " EX 8" O.D. lated Straight Ball Valve ea. Chrome lated Straight Ball Valve - No Lead Brass Stk #2505NL No Lead No lead brass (C6900-ecobrass) 2" EX barb 8" O.D. compression, plated straight ball valve. SS press sleeves sold separately. 2505NL 2" EX 8" O.D. No Lead Brass lated Straight Ball Valve ea. Chrome lated Angle Ball Valve - Brass Stk# " EX barb 8" O.D. compression, plated angle ball valve. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately. otable Water Systems " EX 8" O.D. lated Angle Ball Valve ea. No Lead Chrome lated Angle Ball Valve - No Lead Brass Stk# 2605NL No lead brass (C6900-ecobrass) 2" EX barb 8" O.D. compression, plated angle ball valve. SS press sleeves sold separately. 2605NL 2" EX 8" O.D. No Lead Brass lated Angle Ball Valve ea. Straight Ball Valve - Brass Stk# " EX barb 4" O.D. compression, straight ball valve. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " EX 4" O.D. Straight Ball Valve ea. 04

107 Ball Valves EX Barb Straight Ball Valves - Brass 2700 Series Brass valve. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " EX Straight Ball Valve ea " EX Straight Ball Valve ea. EX Barb Straight Ball Valves - No Lead Brass 2700NL Series No Lead No lead brass (C6900-ecobrass) valve. SS press sleeves sold separately. 2705NL 2" EX Straight No Lead Brass Ball Valve ea. 2722NL 4" EX Straight No Lead Brass Ball Valve ea. Stop and Waste Valves - Brass 2770 Series Brass stop and waste valve. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " EX Stop and Waste Valve ea " EX Stop and Waste Valve ea. 2" EX Barb 2" M/Sweat Straight Ball Valve - Brass Stk# 2405 Brass straight ball valve for 2" pipe. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately. otable Water Systems " EX 2" M/sweat straight Ball Valve ea. 4" EX Barb 4" MT Straight Ball Valve - Brass Stk# 2422 Brass straight ball valve for 4" pipe. The HeatLink brass fittings comply with the NSF International dezincification resistant (DZR) requirements. SS press sleeves sold separately " EX 4" MT Straight Ball Valve ea. 05

108 Other Components 4" EX Insert 4" FT Swivel, Flexible 8" Water Heater Connection Stk# Flexible 8" copper water heater connection with 4" EX insert and 4" FT swivel. SS press sleeves sold separately " EX Insert 4" FT Swivel, Flexible 8" Water Heater Connection 25 ea. 2" EX Insert Closed, " 8" Stubout Elbow with Edge Bracket Stk# Copper stubout elbow allows for 90 transitions between fixtures and wall cavities. SS press sleeves sold separately " EX Stubout Elbow with Edge Bracket ea. 2" EX Insert Male Sweat, " 4" Stubout Elbow Stk# 2824 Copper stubout elbow allows for 90 transitions between fixtures and wall cavities. SS press sleeves sold separately. otable Water Systems " EX M/Sweat, " 4" Tub Elbow 25 ea. 06

109 2" - #05 Accessories, Tools, and arts 4" - #422 2" - #405 4" - #22-4" - #5 " - #28 2" & 4" - #25

110 Accessories J-Clips 2000 Series Fasten tubing to joists " J-Clip ea " J-Clip ea " J-Clip ea. lastic Bend Support 8600 Series Allows for easy bending support and removal lastic Bend Support for 8" and 2" tubing ea lastic Bend Support for 4" tubing ea. Adjustable Angle lastic Drop Ear Bend Support Stk# 8605 Allows for EX tubing to stub out from a wall or floor. Support can be adjusted in 0 steps from straight to 0 bend. New! 8605 Adjustable Angle lastic Drop Ear Bend Support for 2" Tubing 50 ea. Metal Bend Support Series Allows for easy bending support and removal. New! Metal Bend Support for 2" Tubing ea. New! 8629 Metal Bend Support for 5 8" Tubing ea. New! Metal Bend Support for 4" tubing ea. Tools & arts Metal Drop Ear Bend Support Stk# Allows for easy bending support and removal of a EX tubing stub out from a wall or floor. 08 New! Metal Drop Ear Bend Support for 2" Tubing ea.

111 Tools HeatLink Deluxe Staple Gun Stk# 020 Lightweight and easy to use manual staple gun. Use series staples to fasten up to 5 8 (or 20 mm O.D.) EX tubing to polystyrene insulation. New! 020 HeatLink Deluxe Staple Gun ea. Staples for Deluxe Staple Gun Series Staples for fastening up to 5 8" (or 20mm O.D.) EX tubing to polystyrene insulation. For use with HeatLink Deluxe Staple Gun #020. New! 8925 New! " Staples for HeatLink Deluxe Staple Gun 00 2" Staples for HeatLink Deluxe Staple Gun 20 box box Staples for Stand-up Stapler Series Staples for fastening up to 2" (or 8mm O.D.) EX tubing to polystyrene insulation. For use with Stand-up Stapler #0220 (discontinued) " (50 mm) HeatLink Staples for Stand-up Stapler " (60 mm) Staples for Stand-up Stapler 6 box 2 box Tools & arts 09

112 Tools HeatLink EX Tubing Dispenser Stk# 0000 Uncoils in all directions to allow quick installation of EX tubing. Rotates on third axis to remove coil memory tension, making installation easier. Shipped complete with pin set #009 (6"). Optional pin set #0092 (8") for larger coils is also included in the box. Note: Tubing dispensers shipped betweeen Sept. 200 and Sept were equipped with the #009 (6") pin set only. Tubing dispensers shipped prior to Sept. 200 were equipped with the #0092 (8") pin set EX Tubing Dispenser ea. HeatLink Basic EX Tubing Dispenser Stk# 000 Uncoils 60 from the free swinging arm to avoid kinks and enable easy installation of coiled EX tubing. Quick deployment made possible by a slide & clamp design. Comes with carrying/storage bag. 000 Basic EX Tubing Dispenser ea. EX Tubing Cutters Stk# 000 Quick precision cutting on EX tubing or non-metallic tubing. 000 HeatLink EX Tubing Cutters 50 ea. Tools & arts 0

113 Tools EasyFit Nut Wrench Stk# 252 Wrench for use with EasyFit 2" and 4" nuts. 252 EasyFit Nut Wrench ea. Multi-purpose Wrench Stk# Wrench for use with #2200 manifold module nut and valve base Multiwrench for Manifold Nut and Base ea. Assembly Tool for TwistSeal Mini Multiport Valves Stk# 784 Tool used to remove and install TwistSeal Mini Multiport valve cartridges. For use with 7802/ and 7822/ modules. 784 Assembly Tool for TwistSeal Mini Multiport Valves ea. Non-Toxic Silicone O-Ring Lubricant Stk# 7995 & Lubrication for the manifold o-rings. Non-toxic silicone grease. Highly recommended for trouble free installation of manifold components g Bottle Non-Toxic Silicone O-Ring Lubricant 00g Bottle Non-Toxic Silicone O-Ring Lubricant ea. ea. Tools & arts

2008 Canadian List Prices Effective August 1, taxes not included

2008 Canadian List Prices Effective August 1, taxes not included Heat Pure TM Heat - Heating 2008 Canadian List Prices Effective August 1, 2008 - taxes not included International Patents Pure - Plumbing Patents Pending Heat Group Inc. Systems for the Plumbing and Hydronic

More information

Company Profile. HeatLink. Proud beginnings

Company Profile. HeatLink. Proud beginnings Company Profile Heat Proud beginnings The Group is a diverse organization of manufacturing, distribution and franchise operations, with its headquarters based in North America. Heat Group specializes in

More information

Snow Melt EN_US_2014_V2.indb 171 2/7/ :18:52 AM

Snow Melt EN_US_2014_V2.indb 171 2/7/ :18:52 AM 171 Viega snow melting systems are complete hydronic solutions for residential, commercial and industrial applications. All it takes is ViegaPEX Barrier tubing installed in a concrete slab and the proper

More information

Hydraulic Fittings. Design, Manufacture, Distribution

Hydraulic Fittings. Design, Manufacture, Distribution Hydraulic Fittings Design, Manufacture, Distribution Hydraulic Fittings are exclusively distributed by Beaumanor Engineering Ltd of Leicester and manufactured by Balu Auto Components of Chennai India,

More information

INDUSTRIAL HAUL AGREEMENT

INDUSTRIAL HAUL AGREEMENT INDUSTRIAL HAUL AGREEMENT PUBLIC WORKS MEMORANDUM OF AGREEMENT entered into this day of, A.D., 20(yr). BETWEEN: PARKLAND COUNTY a County incorporated under the laws of the Province of Alberta, (hereinafter

More information

Price List. Catalog Eleven. Rigging. Effective February 16, Specialties Inc. manufacturer of stage equipment

Price List. Catalog Eleven. Rigging. Effective February 16, Specialties Inc. manufacturer of stage equipment Price List Catalog Eleven Rigging Effective February 16, 2015 & manufacturer of stage equipment (626) 575-0776 14850 Don Julian Road, Suite B (800) 221-9995 City of Industry CA 91746 www.hhspecialties.com

More information

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual UniTorq UTQ 1.5 6.4 Quarter-Turn Actuator Installation and Operation Manual Thank you for purchasing our UTQ 1.5-6.0 Electric Actuators Before installation or operation of the actuator carefully review

More information

6A-1773 Q ISO-2944

6A-1773 Q ISO-2944 6A-1773 Q1-2801 ISO-2944 Lowery Well Heads, Inc. Quality is #1 We are happy to announce that as of 9-11-15 we are now API Q1 and ISO 9001 certified. Lowery Well Heads, Inc. is committed to its customer

More information

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure S T C TM To Order, Please Specify: 1) Model No., 2) Voltage 2 Way, NC Pilot Piston Stainless Steel Part No. Voltage

More information

SGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement

SGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement SGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement This Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement (the Agreement ) is entered

More information

Wirsbo Radiant Heating System

Wirsbo Radiant Heating System January 1, 2009 PAGE 413-1 Wirsbo Radiant Heating System A1180313 WIRSBO hepex Barrier Tube Cross Linked Polyethylene Heat Transfer tubing with EVOH Oxygen Diffusion Barrier 413-0150 5/16" Nominal hepex:

More information

Product Instructions. Mixing Station. Features. Specifications. Materials

Product Instructions. Mixing Station. Features. Specifications. Materials Mixing Station The Viega Mixing Station provides supply water temperature modulation when connected to a variety of heat sources such as conventional or condensing boilers, water heaters, or geothermal

More information

NAME OF PAGE. Opening paragraph. header. header. header. header PAGE 1

NAME OF PAGE. Opening paragraph. header. header. header. header PAGE 1 NAME OF PAGE PAGE 1 Opening paragraph header header header header 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 8 TABLE OF CONTENTS PAGE 1 PAGE 2-4 Infloor Bpex, Pex Al Pex Tubing and Potable

More information

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT This Net Metering and Interconnection Agreement ( Agreement ) is made and entered into as of this day of, 2018, by the City of Santa

More information

CHOOSING YOUR MANIFOLD & LOCATION

CHOOSING YOUR MANIFOLD & LOCATION CHOOSING YOUR MANIFOLD & LOCATION THOUGHTS ON ZONING The function of a manifold is to distribute the correct flow to each loop to meet its specific heating load. This is achieved by balancing each loop

More information

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GC-1 Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GENERAL INFORMATION The GC-1 heating cable controller has been designed and manufactured for

More information

BY AND BETWEEN AND. The Franchisor and Franchisee are hereinafter collectively referred to as Parties and individually referred to as Party.

BY AND BETWEEN AND. The Franchisor and Franchisee are hereinafter collectively referred to as Parties and individually referred to as Party. FRANCHISE AGREEMENT This Franchise Agreement is accepted on today. BY AND BETWEEN Afflatus Creative Solutions Private Limited, a private limited company, incorporated under the Indian Companies Act, 2013,

More information

To complete the process for a net metering interconnection, please follow the steps below:

To complete the process for a net metering interconnection, please follow the steps below: We appreciate your interest in Pacific Power s net metering program. Before purchasing any net metering equipment, we recommend you review the requirements for interconnecting a net metering system to

More information

California Independent System Operator Corporation Fifth Replacement Electronic Tariff

California Independent System Operator Corporation Fifth Replacement Electronic Tariff Table of Contents 41. Procurement Of RMR Generation... 2 41.1 Procurement Of Reliability Must-Run Generation By The CAISO... 2 41.2 Designation Of Generating Unit As Reliability Must-Run Unit... 2 41.3

More information

Product Catalog. Just because it s in the floor doesn t mean it s INFLOOR.

Product Catalog. Just because it s in the floor doesn t mean it s INFLOOR. Product Catalog Just because it s in the floor doesn t mean it s INFLOOR www.infloor.com TABLE OF CONTENTS Tubing New Style Brass Manifolds & Related Components Current Brass Manifolds & Related Components

More information

Technical Documentation

Technical Documentation Technical Documentation Heating manifold Water manifold Multipurpose manifold Tel:+49 (0)7942-944 926 0 Fax:+49 (0)7942-944 926 99 Form 180 Index Heating manifold 2000... 3 Heating manifold 3000... 5 Insulating

More information

RSPO PalmTrace - Book and Claim Terms and Conditions

RSPO PalmTrace - Book and Claim Terms and Conditions 1. Introduction 1.1 The Roundtable on Sustainable Palm Oil ( RSPO ), a non-profit association registered in Switzerland under Swiss law, supports the following supply chain models for the uptake of certified

More information

Price List. Backfl ow Prevention Products, Repair Kits, and Parts. Effective July 2, AmesFireWater.com 2018 AMES FIRE & WATERWORKS PRICE LIST

Price List. Backfl ow Prevention Products, Repair Kits, and Parts. Effective July 2, AmesFireWater.com 2018 AMES FIRE & WATERWORKS PRICE LIST 2018 AMES FIRE & WATERWORKS PRICE LIST Price List Backfl ow Prevention Products, Repair Kits, and Parts Effective July 2, 2018 All prices supersede previous issues, are temporary and subject to change

More information

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria

More information

TERMS AND CONDITIONS OF SUPPLY

TERMS AND CONDITIONS OF SUPPLY TERMS AND CONDITIONS OF SUPPLY 1.0 Interpretation 1.1 In these terms and conditions, these meanings apply unless the contrary intention appears: "Australian Consumer Law" means the Australian Consumer

More information

Predator. Mobile Heated Adhesive Spray Rig. Parts Identification Manual C-ID June 15, 2005

Predator. Mobile Heated Adhesive Spray Rig. Parts Identification Manual C-ID June 15, 2005 Predator Mobile Heated Adhesive Spray Rig One Gusmer Drive Lakewood, New Jersey, USA 08701-8055 Toll Free 1-800-367-4767 (USA & Canada) Phone: (732) 370-9000 Fax: (732) 905-8968 http://www.graco-gusmer.com

More information

To complete the process for a net metering interconnection, please follow the steps below:

To complete the process for a net metering interconnection, please follow the steps below: We appreciate your interest in Rocky Mountain Power s net metering program. Before purchasing any net metering equipment, we recommend you review the requirements for interconnecting a net metering system

More information

Installation & Operating Instructions for Zone Valve Boxes & Ball Valves

Installation & Operating Instructions for Zone Valve Boxes & Ball Valves V Series Zone Valve Box EV Series Zone Valve Box Ball Valve Page 1 of 9 Introduction The Powerex ball valves and zone valve boxes are cleaned for use with oxygen. Each valve is tested for leakage in both

More information

STC 2L Series Solenoid Valves

STC 2L Series Solenoid Valves STC 2L170-500 Series Solenoid Valves 2L170-500 Series Solenoid Valve Specifications Valve Model 2L170-3/8 2L170-1/2 2L170-3/4 2L200-1 2L300-1 1/2 2L500-2 Valve Type Action 2 Way, Normally Closed (NC) Pilot

More information

No one has more knowledge and experience with PEX Tubing and Radiant Floor Heating Systems than Mr PEX.

No one has more knowledge and experience with PEX Tubing and Radiant Floor Heating Systems than Mr PEX. Parts catalog Why Mr PEX systems? Mr PEX Systems is one of the leading radiant floor heating and domestic hot and cold water systems suppliers in North American marketplace. Our core product, Mr PEX Tubing,

More information

Part Number Description UOM List Price Additional Information

Part Number Description UOM List Price Additional Information 10.05.0000 Profile 5 10x20 metre 4.11 Cutting charge 0.75 10.05.0001 Profile 5 20x20 metre 4.41 Cutting charge 0.75 10.05.0002 Profile 5 20x20 1N metre 6.09 Cutting charge 0.75 10.05.0003 Profile 5 20x20

More information

RIA - VAC SYSTEM PROAGRIA Landbrug A/S Aggershusvej 7 Tlf: DK-5450 Otterup Fax:

RIA - VAC SYSTEM PROAGRIA Landbrug A/S Aggershusvej 7 Tlf: DK-5450 Otterup Fax: RIA - VAC SYSTEM RIA - VAC ASSEMBLY-DIRECTIONS FOR DN 200-250-300 mm RIA VAC LIQUID MANURE DISCHARGE SYSTEM PLAN LONGITUDINAL SECTION (Pipeline with closure cover) PLAN LONGITUDINAL SECTION (Pipeline with

More information

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS PRICE SCHEDULE #101016 EFFECTIVE: OCTOBER 1, 2016 MADE IN BRAZIL, UNLESS NOTED 117 Gulick Street, Blossburg, PA 16912 www.wardmfg.com (800) 248-1027

More information

GWC Valve International

GWC Valve International GWC Valve International PROVEN TECHNOLOGY FOR INDIVIDUAL VALVE SOLUTIONS WORLDWIDE API 6D SWING CHECK VALVES Pressure Class: ASME 150-2500 Size Range: 2-36 CATALOG NUMBER SC-1001 G W C V A L V E I N T

More information

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR) TERMS OF USE 1. Watts pricing and product data is subject to change without notice and such changes supersede all previous versions. 2. Watts data is to be used as provided. Watts is not responsible for

More information

PEX Plumbing & Radiant Heating Systems

PEX Plumbing & Radiant Heating Systems PEX Plumbing & Radiant Heating Systems PEX0118 Customer Guide Effective January 1, 2018 Replaces All Previous Price Lists TABLE OF CONTENTS BY SECTION ZURN PEX PLUMBING PRODUCTS HOT/COLD POTABLE (NON-BARRIER)

More information

Composite PEX-AL-PEX Tubing

Composite PEX-AL-PEX Tubing 04/01/11 page 1.1 Composite PEX-AL-PEX Tubing List Per Foot 40190F ½ Composite Tubing x 200.62 40190 ½ Composite Tubing x 250.62 40190A ½ Composite Tubing x 300.62 40190B ½ Composite Tubing x 1000.62 40192

More information

User Manual Breeze Revision 01.2 September 2018 Tempest Lighting, Inc.

User Manual Breeze Revision 01.2 September 2018 Tempest Lighting, Inc. User Manual Breeze Revision 01.2 September 2018 Tempest Lighting, Inc. Breeze User Manual 1 Table of Contents Introduction... 3 IMPORTANT: Safety Advisories... 3 Installation... 4 Dimensions, Rigging Points,

More information

Dealer Registration. Please provide the following:

Dealer Registration. Please provide the following: Dealer Registration Please provide the following: A copy of your Dealer s License A copy of your Sales Tax Certificate A copy of the Driver s License for all representatives A copy of your Master Tag Receipt

More information

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations Diverting Valve Three-Way Diverting Valves can be used for temperature control in many heating and snowmelting applications. Valve Cross Section Features Includes solder tailpieces (1-1/4" and 1-1/2" models

More information

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way Ordering Part No. = (e.g., E 1/2-3-S) Indicator / Control E 1/2 - - - 3-S Model Name Electric Actuated Valves E Port Size

More information

AMES 2016 Price List. Backflow Prevention Products and Repair Kits and Parts. Effective February 29, 2016

AMES 2016 Price List. Backflow Prevention Products and Repair Kits and Parts. Effective February 29, 2016 AMES 2016 Price List Backflow Prevention Products and Repair Kits and Parts Effective February 29, 2016 All prices supersede previous issues, are temporary and subject to change without notice. AmesFireWater.com

More information

PVI 60KW, PVI 82KW, PVI 95KW

PVI 60KW, PVI 82KW, PVI 95KW PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy

More information

COMPRESSED AIR LOADER MODEL: AL-1

COMPRESSED AIR LOADER MODEL: AL-1 COMPRESSED AIR LOADER MODEL: AL-1 Document: AL-1 IM 10-22-2011 TABLE OF CONTENTS Important Notices and Precautions 3 Quick Installation 4 Product Description 4 Principle of Operation 5 Unpacking and Inspection

More information

STC 2W Series Solenoid Valves

STC 2W Series Solenoid Valves STC 2W160-500 Series Solenoid Valves 2W160-500 Series Solenoid Valve Specifications Valve Model 2W160-3/8 2W160-1/2 2W200-3/4 2W250-1 2W350-1 1/4 2W400-1 1/2 2W500-2 Valve Type Action 2 Way, Normally Closed

More information

AXIJET LEADLAG EXHAUST FAN CONTROL SYSTEM

AXIJET LEADLAG EXHAUST FAN CONTROL SYSTEM AXIJET LEADLAG EXHAUST FAN CONTROL SYSTEM (Patent Pending) INTRODUCTION INTRODUCTION AND FEATURES Laboratory Exhaust Systems that utilize multiple fans in an N + 1 design must sequence the standby fan

More information

Public Access Electric Vehicle Charging Station Rebate Program Agreement

Public Access Electric Vehicle Charging Station Rebate Program Agreement Public Access Electric Vehicle Charging Station Rebate Program Agreement The City of Anaheim (City) is offering rebates to commercial, industrial, institutional, and municipal customers who install Level

More information

10 Year Limited Warranty

10 Year Limited Warranty Power. On Your Terms. 10 Year Limited Warranty PHI 2.7 TM PHI 3.5 TM 60A SIMPLIPHI POWER, INC. REV020618 10 Year Limited Warranty: PHI 2.7 TM PHI 3.5 TM 60A 24V 48V Limited Pro-Rated Warranty Coverage

More information

Parts List 885 Series

Parts List 885 Series Parts List Effective: October 15, 2001 Supersedes: P410-885 Dated September 2000 WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN

More information

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions Level Alert Model 2000 Multi-Switch Liquid Level Sensor Assembly and Installation Instructions Kit Form Each unit is provided in kit form with step-by-step instructions, making it extremely easy to custom

More information

HEATING SYSTEMS PRICE LIST 07 / 2008 TABLE OF CONTENTS

HEATING SYSTEMS PRICE LIST 07 / 2008 TABLE OF CONTENTS PRICE LIST 07 / 2008 TABLE OF CONTENTS PE-RT (PEOC -PLUS DOWLEX ) Pipe 2 Tools 3 Bend supports & sleeves 4 Slab on grade tubing fastening components 4 Plastic pipe hangers 5 Brass Fittings (Compression)

More information

1. In these Terms and Conditions and unless the context otherwise requires:

1. In these Terms and Conditions and unless the context otherwise requires: DEFINITIONS 1. In these Terms and Conditions and unless the context otherwise requires: 1.1 Account Holder means the Principal Cardmember or Corporate Cardmember in whose name a Card Account has been opened

More information

Individual Fuel Card Application Form

Individual Fuel Card Application Form Individual Fuel Card Application Form INDIVIDUAL FUEL CARD APPLICATION FORM PART 1: AUTHORISED APPLICANT S DETAILS Full Name, Underline Surname (As in IC/Passport): Mr Ms Mrs Mdm Dr NRIC / FIN / ID / Passport

More information

Why MrPEX? Table of Contents

Why MrPEX? Table of Contents May 1, 2018 Table of Contents About MrPEX Systems MrPEX Systems is one of the leading North American system suppliers of residential and commercial radiant heating/cooling, snowmelt systems, and now offering,

More information

SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT

SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT INTERCONNECTION AGREEMENT FOR SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION THIS AGREEMENT MUST ACCOMPANY

More information

Siemens AG Modern design and easy handling for charging at home or in the semi-public area

Siemens AG Modern design and easy handling for charging at home or in the semi-public area s Drivergy WB140A charging unit Modern design and easy handling for charging at home or in the semi-public area Easy charging at home WB140A charging unit: Modern, functional design and easy handling combine

More information

DCLI GENSET INTERCHANGE AGREEMENT

DCLI GENSET INTERCHANGE AGREEMENT DCLI GENSET INTERCHANGE AGREEMENT THIS GENSET INTERCHANGE AGREEMENT (this Agreement ), dated, is by and between Direct ChassisLink, Inc. ( DCLI ) and ( Motor Carrier ). 1. Scope of Agreement. DCLI hereby

More information

STC 2P025 Series Solenoid Valve

STC 2P025 Series Solenoid Valve STC 2P025 Series Solenoid Valve 2P025 Series Solenoid Valve Specifications Valve Model Valve Type Action Cv (Orifice) Operating Pressure Operating Temperature 2P025 2 Way, Normally Closed (NC) Direct Acting

More information

Power. On Your Terms.

Power. On Your Terms. Power. On Your Terms. 10 YEAR LIMITED WARRANTY PHI 1310 TM 1 SIMPLIPHI POWER, INC. REV102016 10 YEAR LIMITED WARRANTY: PHI 1310 TM LIMITED PRO-RATED WARRANTY COVERAGE The SimpliPhi Power PHI 1310 as supplied

More information

Table of Contents Introduction 3 Chapter 2: Operation 4 Chapter 3: Components 5 Chapter 4: Specifications 8

Table of Contents Introduction 3 Chapter 2: Operation 4 Chapter 3: Components 5 Chapter 4: Specifications 8 Table of Contents Introduction 3 Application 3 Chapter 2: Operation 4 Manifold Function 4 Chapter 3: Components 5 Required Parts 5 Manifold without Actuators without Pressure Bypass Kit 5 Pump Kit (QHMPK_)

More information

Motorized Control Valves

Motorized Control Valves Motorized Control Valves Gland Connector Sold as Option. See page XX. Reference coil option chart for additional electrical coil offerings. AC control systems industrial boilers water and purification

More information

BC Brake Caliper 1 FORM NO. L D-0414

BC Brake Caliper 1 FORM NO. L D-0414 BC Brake Caliper FORM NO. L-0066-D-044 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject to change without notice. Technical

More information

Parking Terms and Conditions

Parking Terms and Conditions Parking Terms and Conditions These Terms and Conditions apply as from 1 June 2016 and replace any and all prior general terms and conditions that form part of one-off parking agreements. Access to the

More information

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev Patent No. 6520259 Installation Manual P/N 95232 Rev 6-16-11 Table of Contents ing Extraction Inlets track changing water levels to maintain optimum performance 1.Component Identification Page 1 2. How

More information

As Introduced. 132nd General Assembly Regular Session S. B. No

As Introduced. 132nd General Assembly Regular Session S. B. No 132nd General Assembly Regular Session S. B. No. 194 2017-2018 Senator Terhar Cosponsor: Senator Wilson A B I L L To amend sections 4505.101, 4513.601, and 4513.611 of the Revised Code to require only

More information

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves STC 2DS500-2000 Series Anti-Hammering Slow Closing Pilot Solenoid Valves 2DS500-2000 Series Solenoid Valve Specifications Valve Model 2DS400F 2DS500F 2DS650F 2DS800F 2DS1000F 2DS1250F 2DS1500F 2DS2000F

More information

USAACE & Fort Rucker Preventative Law Program. Alabama Lemon Law

USAACE & Fort Rucker Preventative Law Program. Alabama Lemon Law USAACE & Fort Rucker Preventative Law Program Alabama Lemon Law THIS PAMPHLET contains basic information on this particular legal topic for your general information. If you have specific questions, contact

More information

DEALER REGISTRATION PACKAGE

DEALER REGISTRATION PACKAGE DEALER REGISTRATION PACKAGE. Please return this completed paperwork by mail, fax or email: Sunflower Auto Auction P.O. Box 19087 Topeka, Kansas 66619 PHONE 785-862-2900 FAX 785-862-2902 Email:info@SunflowerautoAuction.com

More information

User s Manual for Tennessee Chill Box System P/N CB8000

User s Manual for Tennessee Chill Box System P/N CB8000 User s Manual for Tennessee Chill Box System P/N CB8000 Read and understand all instructions before using this product. Open carton carefully and inspect product for damage caused by carrier. If any damage

More information

TRUCK PRODUCT LINE A DIVISION OF DAKOTA FLUID POWER, INC.

TRUCK PRODUCT LINE A DIVISION OF DAKOTA FLUID POWER, INC. TRUCK PRODUCT LINE 2210 Main Ave W, West Fargo, ND 58078 877.410.7072 www.epgdivision.com A DIVISION OF DAKOTA FLUID POWER, INC. ABOUT US About: Engineered Products Group (EPG), a division of Dakota Fluid

More information

EV Service Pilot Customer Service Agreement

EV Service Pilot Customer Service Agreement EV Service Pilot Customer Service Agreement Xcel Energy is excited to offer the Electric Vehicle Service Pilot ( Pilot ) to its Minnesota residential rate electric customers. As part of the Pilot, Xcel

More information

To complete the process for a net metering interconnection, please follow the steps below:

To complete the process for a net metering interconnection, please follow the steps below: We appreciate your interest in Pacific Power s net metering program. Before purchasing any net metering equipment, we recommend you review the requirements for interconnecting a net metering system to

More information

FADE Series Wall Axial Fans

FADE Series Wall Axial Fans Installation and Operation Manual Item #: 401442 Rev Date: 070113 FADE Series Wall Axial Fans Fantech Inc. certifies that the FADE Series shown herein is licensed to bear the AMCA Seal. The ratings shown

More information

EWS FLUID END PARTS LIST

EWS FLUID END PARTS LIST GARDNER DENVER Rev C September 2005 WELL SERVICING PUMP MODEL C-2500 QUINTUPLEX EWS FLUID END PARTS LIST ECN 1027623 C-2500 WELL SERVICING PUMP MAINTAIN PUMP RELIABILITY AND PERFORMANCE WITH GENUINE GARDNER

More information

Model SPI FF 18/18 Proportioning Unit

Model SPI FF 18/18 Proportioning Unit Model SPI FF 18/18 Proportioning Unit Parts Identification Manual 17942-SPI-ID February 1, 2005 Issue 7 GUSMER CORPORATION One Gusmer Drive Lakewood, New Jersey, USA 08701-8055 Toll Free 1-800-367-4767

More information

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation GRUNDFOS INSTRUCTIONS Grundfos Variable Speed Installation and Operation Pumps Incorporating the (VS) Variable Speed Control with Date Code 0838 or higher 1. 2. 3. 4. Shipment Inspection General Features

More information

4V130P-430P SERIES AIR PILOT VALVE

4V130P-430P SERIES AIR PILOT VALVE 4V130P-430P SERIES AIR PILOT VALVE Valve Model 4V130P-1/8 4V230P-1/4 4V330P-3/8 4V430P-1/2 Port & Mounting Action & Motion Operating Pressure Body Ported Double Solenoid, Spool Design, 3 Position, Pressure

More information

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS PRICE SCHEDULE #100217 EFFECTIVE: FEBRUARY 6, 2017 REV. 1 MADE IN BRAZIL, UNLESS NOTED 117 Gulick Street, Blossburg, PA 16912 (800) 248-1027 Sheet #100217,

More information

Montana-Dakota Utilities Co. A Division of MDU Resources Group, Inc. 400 N 4 th Street Bismarck, ND 58501

Montana-Dakota Utilities Co. A Division of MDU Resources Group, Inc. 400 N 4 th Street Bismarck, ND 58501 Original Sheet No. 72 Page 1 of 7 AVAILABILITY: Available to any customer that owns and operates a solar, wind or hydroelectric generating facility with a capacity of not more than 25 Kw that is located

More information

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL 62545 Telephone: 217 / 364-4467 Fax: 217 / 364-4494 OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS WHAT TO DO FIRST Upon receiving your new pump set system

More information

2V1-3V1 SERIES SOLENOID VALVE

2V1-3V1 SERIES SOLENOID VALVE 2V1-3V1 SERIES SOLENOID VALVE Valve Model 2V1 3V1 Port & Mounting Body Ported, Stacking Action & Motion Solenoid, Direct Acting, 2 Way Response Time

More information

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter

More information

To complete the process for a net metering interconnection, please follow the steps below:

To complete the process for a net metering interconnection, please follow the steps below: We appreciate your interest in Pacific Power s net metering program. Before purchasing any net metering equipment, we recommend you review the requirements for interconnecting a net metering system to

More information

Price list april 2015

Price list april 2015 Price list april 2015 radiator model total height dimensions in mm pipe centres depth length ø connections heat output EN 4 T C Watt Kcal/h. white section special coloured section GL / 890 183 158 23,60

More information

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO MEX (55) 5 6 QRO (44) 95 7 60 MTY () 54 0 BC Brake Caliper (i) FORM NO. L-0066-B-040 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this

More information

V Product Catalog RADIANT HEATING & COOLING PLUMBING SNOWMELT CONTROLS

V Product Catalog RADIANT HEATING & COOLING PLUMBING SNOWMELT CONTROLS V-1025 Product Catalog RADIANT HEATING & COOLING PLUMBING SNOWMELT CONTROLS MAY 1, 2017 Table of Contents ABOUT MrPEX SYSTEMS MrPEX Systems is one of the leading North American system suppliers of residential

More information

MECHANICAL SECTIONS TRAINING EQUIPMENT MADE IN ITALY

MECHANICAL SECTIONS TRAINING EQUIPMENT MADE IN ITALY MECHANICAL SECTIONS TRAINING EQUIPMENT MADE IN ITALY Index FLUID MECHANICS & REFRIGERATION INDUSTRIAL WATER PUMPS/TURBINES AND ACCESSORIES - CUTAWAY....170-179 Water pumps.... Valves.... Motor pumps....

More information

TERMS AND CONDITIONS OF PARKING AT PALMERSTON NORTH AIRPORT

TERMS AND CONDITIONS OF PARKING AT PALMERSTON NORTH AIRPORT TERMS AND CONDITIONS OF PARKING AT PALMERSTON NORTH AIRPORT 14 December 2017 Palmerston North Airport Limited ( PNAL ) provides travellers and other members of the public with multiple car parking options

More information

Air-Boss VP Intake Plenum

Air-Boss VP Intake Plenum Installation Manual P/N 98502-ABIP 98.5-02 DODGE CUMMINS Air-Boss VP Intake Plenum Installation Instructions P/N 98502-ABIP GDP Air-Boss VP Plenum Installation PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING

More information

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Installation / Operation Instructions Sunnex ORION Series Exam Lights Installation / Operation Instructions Sunnex ORION Series Exam Lights OR-120 OR-127 OR-220 OR-227 Models: OR-300 OR-400 OR-500 OR-600 1. APPLICATIONS The Sunnex ORION Series light was designed specifically

More information

3V SERIES SOLENOID VALVE

3V SERIES SOLENOID VALVE 3V110-410 SERIES SOLENOID VALVE Valve Model 3V110-1/8 3V210-1/4 3V310-3/8 3V410-1/2 Port & Mounting Action & Motion Operating Pressure Body Ported Air Pilot, Spool Design, Response Time

More information

4-Way Mixing Panel Submittal - Page 1 of 6

4-Way Mixing Panel Submittal - Page 1 of 6 Submittal - Page 1 of 6 Job or Customer : Location : Engineer : Complies with Spec Alternate Notes : Contractor : Heat Rep : Submitted By : Date : Approved By : Date : P.O. Number : Date : Description

More information

VLC5501 Immobiliser installation manual

VLC5501 Immobiliser installation manual VLC5501 Immobiliser installation manual Installation manual - Version 2.3 Attention!!! Installation of this security product is additional protection for your vehicle, but it does not protect your vehicle

More information

6. Electrical. 7. Settings. 8. Quick

6. Electrical. 7. Settings. 8. Quick Grundfos Variable Speed Circulator Pump Pumps Incorporating the VS, Variable Speed Control 1. Shipment Inspection Page 2 2. General Page 2 3. Operational Limits Page 3 4. Pump Installation Page 4 5. Installation

More information

Proven technology for individual valve solutions worldwide. GWC Valve International

Proven technology for individual valve solutions worldwide. GWC Valve International Proven technology for individual valve solutions worldwide FORGED STEEL VALVES GATE, GLOBE & CHECK PRESSURE CLASS: ASME 150-2500 SIZE RANGE: 1/4-3 API STANDARD: 602 ASME B16.34 Catal og Nu mb er f SV-

More information

PRICE SHEET TABLE OF CONTENTS AWWA VALVES & HYDRANTS. (PL-0418-AWWA Replaces PL-1014-VLV)

PRICE SHEET TABLE OF CONTENTS AWWA VALVES & HYDRANTS. (PL-0418-AWWA Replaces PL-1014-VLV) Page(s) 1 2 3 3 4 4 5 5 6 PRICE SHEET TABLE OF CONTENTS VALVES & HYDRANTS ( Replaces PL-1014-VLV) Product Line C515 NRS Gate Valves Series 1010 UL/FM C515 NRS Gate Valves Series 2010 C508 Swing Check Valves

More information

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX 900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump. Part # AF-03-326 2015 Pentair Ltd. 01/30/15

More information

HP190SL Series Slimline Radon Fans

HP190SL Series Slimline Radon Fans Installation and Operation Manual Item #: 412843 Rev Date: 070113 HP190SL Series Slimline Radon Fans United States 10048 Industrial Blvd., Lenexa, KS, 66215 Tel.: 800.747.1762 Fax: 800.487.9915 Canada

More information

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications Manufactured in ISO9000:2000 Facility Manufactured to ASTM/ASME A182/SA182 Items conform

More information

60 Hz Pump Performance Curves, Selection and Specifications

60 Hz Pump Performance Curves, Selection and Specifications ANSI, solid Kynar or Teflon non-metallic centrifugal pumps 6 Hz Pump Performance Curves, Selection and Specifications WANNER ENGINEERING INC United States Instant Information: www.wannereng.com (612) 332-5681

More information