Technical Documentation

Size: px
Start display at page:

Download "Technical Documentation"

Transcription

1 Technical Documentation Heating manifold Water manifold Multipurpose manifold Tel:+49 (0) Fax:+49 (0) Form 180

2 Index Heating manifold Heating manifold Insulating spout... 8 Multizone One pipe manifold 2000 / Flowmeter Water manifold Multipurpose manifold Terms of Sale, Delivery and Payment Page 2

3 -Heating manifold 2000 Cabinet or wall holder universal Cabinet or wall holder 95 mm ½ internal thread G 1 G 1 1/ ¾ external thread euro-cone Total length L Number of circuits Total length L (mm) Length of threaded bars (mm) Application area: Suitable for water, water glycol mixture up to 30% concentration. Request written release of the manufacturer, if rust-proofing or anti-freezing agents, acids or leaches or other additives are used. Not suitable for areas where ammonia or ammoniacal compounds occur. No direct solar radiation in outside areas! Protect against UV-radiation! Installation only in dry environment, if operating or ambient temperatures are below freezing point. max. test pressure: max. positive operating pressure: Operating temperatures: 10 bar. Execute pressure test 6 bar -20 C to +90 C only with water! Material: Case made of plastic, brass parts made of CuZn40Pb2, gaskets made of EPDM Tightening torques: Nuts M8: 4 Nm Page 3

4 -Heating manifold 2000 Miscellaneous: Use screw connections which make an easy exchange of the manifold possible. Close not connected manifold circuits with plugs or caps. The connected pipes at the manifold circuit may not exert permanent tensile or pressure load on the manifold. The manifold circuits are rotatable 180 against each other. They can be adapted on different pipe distances by spacers. The manifold installation: 1. Cut threaded bars to length and screw them into connection block. 2. Put off individual modules (pay attention to position of o-ring). 3. Put on end plate with plastic hood facing inside. 4. Tighten nuts until modules lie together Insert o-ring in connection block Pay attention to position of the centerings Page 4

5 -Heating manifold 3000 Miscellaneous: Use screw connections which make an easy exchange of the manifold possible. Close not connected manifold circuits with plugs or caps. Additionally the valve of the supply and the flowmeter of the return module have to be closed completely. The connected pipes at the manifold circuit may not exert permanent tensile or pressure load on the manifold. The manifold circuits are rotatable 180 against each other. -Heating manifold Flow characteristic Flow characteristic th determined at 5 circuit Supply max. open Return preset Manifold schema dp Example: Supply (red) Return (blue) Pump pressure and pressure drop respectively 0,15bar Desired flow 250 l/h Open valve maximal, then 6 turns to the right Flow rate Q 2000 (l/h) max. open 1.5 turn closed 3 turns closed 4.5 turns closed 5.25 turns closed 6 turns closed 6.75 turns closed 7.5 turns closed 7.8 turns closed 0,1 0,2 0,3 0,4 0,6 0,8 1,0 1, (mws) 0,01 0,02 0,04 0,1 0,15 0,2 0,3 0,4 0,6 0,8 1,0 Example Pressure drop dp 1,83 1,43 1,20 1,02 0,85 0,63 0,47 0,33 0,21 Kv-value (bar) Supply valve Valve open 14.3 ±0.15 Spring force: 45 N Valve closed M30x1.5 SW ± minimum requirements for actuator: Spring force: > 80 N Prestress at assembly > 0,5 mm Lifting height: > 3,5 mm Page 6

6 -Heating manifold 3000 Handwheel supply valve Cabinet or wall holder universal Cabinet or wall holder 95 mm 4 x G ½ G 1 G 1 1/ ¾ external thread euro-cone Cap flowmeter Total length L Number of circuits Total length L (mm) Length of threaded bars (mm) Application area: Suitable for water, water glycol mixture up to 30% concentration. Request written release of the manufacturer, if rust-proofing or anti-freezing agents, acids or leaches or other additives are used. Not suitable for areas where ammonia or ammoniacal compounds occur. No direct solar radiation in outside areas! Protect against UV-radiation! Installation only in dry environment, if operating or ambient temperatures are below freezing point. max. test pressure: max. positive operating pressure: Operating temperatures: 10 bar. Execute pressure test 6 bar -20 C to +90 C only with water! Rinse and fill: The manifold may rinsed and filled only in flow direction. Material: Case made of plastic, brass parts made of CuZn40Pb2, gaskets made of EPDM Tightening torques: Nuts M8: Supply valve: Flowmeter: 4 Nm 10 Nm 10 Nm Page 5

7 -Heating manifold Flowmeter If the German Construction Contract Procedures for orders are agreed, each specialized craftsman is legally obligated not only to make the hydraulic balancing during the installation of floor heatings but also to prove it (VOB, part C, DIN heating systems). It s also state-of-the-art to balance heating systems hydraulically. Furthermore the hydraulic balancing is physically mandatory, because water searches the line of the least resistance. The hydraulic balancing: The individual circuits of a floor heating have to be coordinated and adjusted in that way, that each circuit receives only the volume flow which is necessary for the respective heating output. The required volume flow can be easily and quickly adjusted by the standard integrated flowmeter of the SBK Heating manifold Procedure: Heating system has to be completely filled an deaerated, operating pressure has to be existent! Close all flowmeters of the return manifold, open all valves of the supply manifold. Adjust volume flow of the first circuit by turning the transparent plastic pipe according to the heat requirement calculation (use handwheel of the supply valve). Indicator pin of the plastic pipe rises upward. Turn plastic pipe as far as the indicator pin indicates the desired value. Balance next circuit as aforementioned. Put the handwheel from the supply module on the flowmeter and adjust the desired water quantity by turning Protect hydraulic balancing against unauthorized adjusting Close flowmeter with cap and provide it with a lead Plastic pipe Cap Return module Indicator pin Flowmeters with different indicating ranges are available for different flow rates SBK Heating manifold 3000 Return module with integrated flowmeter l/h l/min l/h l/min l/h l/min l/h l/min Indicator pin blue Indicator pin green Indicator pin red Indicator pin yellow Page 7

8 - Insulating spout By use of the SBK heating manifold 3000 in space cooling systems, condensation can be formed on the metal parts if the rope's point is undercut. Especially in the area of the clamp ring screw connection this can be mainly prevented by use of the insulating spout. The insulating spout is suited for clamp ring screw connections external thread euro cone ¾ and pipe diameter from Ø 12 to 20 mm. Picture 1 Assembly 1. Push insulating spout over the pipe before assembly of the clamp ring screw connection. 2. Screw on pipe with screw connection as usual on the manifold circuit. Now the insulating spout can be pushed over the clamp screw connection until the sealing lip lays on the manifold module. clamp screw connection insulating spout insulating spout plastic pipe plastic pipe Picture 2 Picture 3 Page 8

9 -Multizone 3000 The SBK-Multizone 3000 can easily combine 2 or 3 heating circuits into one control zone due to its modular nature. The hydraulic balancing of the heating circuits remains possible by the flowmeter in the return module. Specification of the components: Zone valve 3000, with thermostatic valve Controls the flow of the heating water to the following Multizone heating circuits. Change-over to electric actuator possible. Attention: First module of the Multizone in flow direction Intermediate module 3000 Pass to following modules (for both single circuits and Multizone heating circuits). Attention: Second module of the Multizone in flow direction End module 3000 Pass to following single circuits and limitation of the last Multizone heating circuit. Attention: Last module of the Multizone in flow Installation information: Pay absolutely attention to order and flow direction Single circuit Triple Multizone consists of: zone valve-intermediate module-end module Double Multizone consists of: zone valve-end module Single circuit Flow direction Heating supply Installation direction Application area, pressure and temperature, material, tightening torques: see Heating manifold 3000 Page 9

10 Differential pressure relief valve for Heating manifold 3000 Description: The SBK Differential pressure relief valve for Heating manifold 3000 has the function to maintain a minimum water circulation or to reduce flow noises in a heating or cooling system. For that a Bypass-tube is connected between a Supply module and a Return module of the heating manifold. Instead of the flowmeter the Differential pressure relief valve is fitted in the Return module. The Differential pressure relief valve opens the Bypass in case of the differential pressure between supply and return is higher than the set value at the Differential pressure relief valve. So the heating system provides a minimum of water circulation also when all valve actuators are closed. For example mounted in an heat pump system. Advantages SBK Differential pressure relief valve: - infinitely adjustable pressure setting - Display Set value by scale - easy fitting / refitting - Bypass-tube included handwheel supply valve (open) Differential pressure relief valve Bypass Set Value Differential pressure [bar] 0 0,1 0,2 0,3 0,4 0,5 Application area: Suitable for water, water glycol mixture up to 30% concentration. Request written release of the manufacturer, if rust-proofing or anti-freezing agents, acids or leaches or other additives are used. Not suitable for areas where ammonia or ammoniacal compounds occur. No direct solar radiation in outside areas! Protect against UV-radiation! Installation only in dry environment, if operating or ambient temperatures are below freezing point. max. test pressure: max. positive operating pressure: Operating temperatures: 10 bar. Execute pressure test 6 bar -20 C to +90 C only with water! Material: Case made of plastic, brass parts made of CuZn40Pb2, gaskets made of EPDM Tightening torques: Nuts M8: Supply valve: Flowmeter: 4 Nm 10 Nm 10 Nm Page 10

11 -Installation kit for one pipe manifold 2000 / 3000 Because of on site conditions it isn t always possible to install the supply and return manifold beams separately. Therefore we have the installation kits for one pipe manifold 3000 and 2000 in our product range. The manifold beams can be assembled in one line with these installation kits. The series 3000 has an overall height of 80 mm, the series 2000 of 75 mm. Each installation kit consists of: Connection block diagonally drilled with o-ring Separation plate 5 mm black with o-ring Intermediate plate 2 mm black Sleeve nut M8x25 galvanized 1 pcs 1 pcs 1 pcs 2 pcs Additionally the wall or cabinet holder 75 mm high (Item no ) is required. The installation kits differ only in the type of their connection blocks diagonally drilled 3000 or Installation information: Screw in threaded bars M8 into standard connection block. Put off one required supply module after the other. Put off separation plate 5 mm black with o-ring ( pay attention to position of o-ring). Put off the required number of return modules. Put off intermediate plate 2 mm black. Put off connection block diagonally drilled and screw it with sleeve nuts M8x25 galvanized. Supply module Return module Connection block diagonally drilled Connection block standard Separation plate 5 mm Intermediate plate 2 mm Sleeve nut M8x25 Wall or cabinet holder 75 mm Installation direction Page 11

12 -Installation kit for one pipe manifold 2000 / 3000 Application area: Suitable for water, water glycol mixture up to 30% concentration. Request written release of the manufacturer, if rust-proofing or anti-freezing agents, acids or leaches or other additives are used. Not suitable for areas where ammonia or ammoniacal compounds occur. No direct solar radiation in outside areas! Protect against UV-radiation! Installation only in dry environment, if operating or ambient temperatures are below freezing point. max. test pressure: max. positive operating pressure: Operating temperatures: 10 bar. Execute pressure test 6 bar -20 C to +90 C only with water! Rinse and fill: The manifold may rinsed and filled only in flow direction. Material: Case made of plastic, brass parts made of CuZn40Pb2, gaskets made of EPDM Tightening torques: Nuts M8: Supply valve: Flowmeter: 4 Nm 10 Nm 10 Nm Miscellaneous: Use screw connections which make an easy exchange of the manifold possible. Close not connected manifold circuits with plugs or caps. Additionally the valve of the supply and the flowmeter of the return module have to be closed completely. The connected pipes at the manifold circuit may not exert permanent tensile or pressure load on the manifold. The manifold circuits are rotatable 180 against each other. They can be adapted on different pipe distances by spacers. Page 12

13 -Flowmeter If the German Construction Contract Procedures for orders are agreed, each specialized craftsman is legally obligated not only to make the hydraulic balancing during the installation of floor heatings but also to prove it (VOB, part C, DIN heating systems). It s also state-of-the-art to balance heating systems hydraulically. Furthermore the hydraulic balancing is physically mandatory, because water searches the line of the least resistance. The hydraulic balancing: The individual circuits of a floor heating have to be coordinated and adjusted in that way, that each circuit receives only the volume flow which is necessary for the respective heating output. The required volume flow can be easily and quickly adjusted by the standard integrated flowmeter of the SBK Heating manifold Procedure: Heating system has to be completely filled an deaerated, operating pressure has to be existent! Close all flowmeters of the return manifold, open all valves of the supply manifold. Adjust volume flow of the first circuit by turning the transparent plastic pipe according to the heat requirement calculation (use handwheel of the supply valve). Indicator pin of the plastic pipe rises upward. Turn plastic pipe as far as the indicator pin indicates the desired value. Balance next circuit as aforementioned. Put the handwheel from the supply module on the flowmeter and adjust the desired water quantity by turning Protect hydraulic balancing against unauthorized adjusting Close flowmeter with cap and provide it with a lead Plastic pipe Cap Return module Indicator pin Tightening torque: 10 Nm Flowmeters with different indicating ranges are available for different flow rates SBK Heating manifold 3000 Return module with integrated flowmeter l/h l/min l/h l/min l/h l/min l/h l/min Indicator pin blue Indicator pin green Indicator pin red Indicator pin yellow Page 13

14 -Water manifold 4001 AG 1½" G 1¼" Ø L 9 ca. 100 ca. 128 Number of circuits Total length (mm) Length of threaded bars M8 galvanized (mm) Application area: Suitable for water, water glycol mixture up to 30% concentration. Request written release of the manufacturer, if rust-proofing or anti-freezing agents, acids or leaches or other additives are used. Not suitable for areas where ammonia or ammoniacal compounds occur. Don t apply in outside areas! Protect against UV-radiation! Installation only in dry environment, if operating or ambient temperatures are below freezing point. max. test pressure: max. positive operating pressure: Operating temperatures: 10 bar. Execute pressure test 6 bar blue -20 C to +20 C only with water! Material: Case made of plastic, brass parts made of CuZn40Pb2, gaskets and bellow made of EPDM Tightening torques: Nuts M8: 4 Nm Upper part with bellow: 20 Nm Upper part with non-return flap: 20 Nm The manifold installation: 1. Cut threaded bars to length and screw them into connection block, put off flat gasket. 2. Put off individual modules with flat gasket. 3. Put on end plate. 4. Tighten nuts until modules lie together. Page 14

15 -Water manifold 4001 Flow rate value: 1,02 l/s by dp 0,1 bar Miscellaneous: Use screw connections which make an easy exchange of the manifold possible. Close not connected manifold circuits with plugs or caps. The connected pipes at the manifold circuit may not exert permanent tensile or pressure load on the manifold. The manifold circuits are rotatable 180 against each other. They can be adapted on different pipe distances by spacers. Page 15

16 -Water drain gutter E A B C D G F H all measures in mm Item no. Overall length / version A B C D E F G H mm / plastic mm / plastic mm / plastic Installation and application examples: Water manifold 4001 Connection on the left Two circuits up, one circuit down Spacers between the circuits for an exact adaptation to an Water manifold 4001 Connection on the left Three circuits up, one circuit down With drain gutter and mounting clamp for a simple and quick installation Page 16

17 -Water manifold Installation instructions upper part with bellow False! Spindle is unscrewed too much. Bellow doesn t lie against upper part. False! Spindle is screwed in too much. Bellow doesn t lie against upper part. Right! Bellow lies against upper part. Now screw in into plastic case. Page 17

18 -Multipurpose manifold 5000 KST 1¼ End plate optional: -without internal thread -with ½ internal thread -¾ internal thread -1 internal thread from heat pump optional 1¼ internal thread or 1½ internal thread 200 to heat pump optional 1¼ internal thread or 1½ internal thread Internal thread 1" Total length L 292 Number of circuits Total length L (mm) Length of threaded bars (mm) Multipurpose manifold 5000 KST 1¼ - Flow characteristic Measuring section: Inflow = G1½, Outflow = G1½, Connection between supply and return manifold: straight pipe sections G1, ca. 100 mm long Valves of the supply and flowmeters of the return max. open Medium water 18 C Flow rate Q = l/h by dp = 1 bar max Flow rate Q (l/h) circuits 02 circuits 01 circuit Number of manifold circuits 500 0,01 0,1 1,0 Pressure drop dp (bar) Page 18

19 -Multipurpose manifold 5000 KST 2 End plate optional: -without internal thread -with ½ internal thread -¾ internal thread -1 internal thread from heat pump 2 internal thread 200 to heat pump 2 internal thread 73 Internal thread 1" Total length L Number of circuits Total length L (mm) Length of threaded bars (mm) Multipurpose manifold 5000 KST 2 - Flow characteristic Measuring section: Inflow = G2, Outflow = G2, Connection between supply and return manifold: straight pipe sections G1, ca. 100 mm long Valves of the supply and flowmeters of the return max. open circuits 04 circuits 03 circuits 02 circuits Medium water 18 C Flow rate Q = l/h by dp = 1 bar max Flow rate Q (l/h) circuit Number of manifold circuits 500 0,01 0,1 Pressure drop dp (bar) 1,0 Page 19

20 -Multipurpose manifold 5000 manifold installation Pay attention on cleanness during the manifold installation. The gaskets may not encounter oil or lubrication grease. 1. Cut threaded bars to lengths and screw them into connection block. 2. Apply connection block with threaded bars vertical to a fixed base. 3. First put off one flat gasket and then the manifold module. 4. Put off one flat gasket once again after the last manifold module. 5. Put on the end plate. 6. Tighten the nuts until modules lie together (torque 8 Nm). Nuts M8 End plate Flat gasket Threaded bars M8 Connection block Manifold module Flat gasket Application area: Released for water & water glycol mixtures as per manufacturer s instructions. (TYFOCOR L, TYFOCOR, TYFO-Spezial ) Request written release of the manufacturer, if rust-proofing or anti-freezing agents, acids or leaches or other additives are used. Conditionally suitable for areas where ammonia or ammoniacal compounds occur. No direct solar radiation in outside areas! Protect against UV-radiation! Installation only in dry environment, if operating or ambient temperatures are below freezing point. Only screw connections made of plastic are permitted as circuit screw connections. We recommend Pipe Sealing Cord Loctite 55. Notice the Product information. max. test pressure: max. positive operating pressure: Operating temperatures: 10 bar. Execute pressure test 6 bar -20 C to +70 C only with water! Rinse and fill: The manifold may rinsed and filled only in flow direction. Material: Case made of plastic, brass parts made of CuZn40Pb2, gaskets made of EPDM Tightening torques: Supply valve/flowmeter: 30 Nm Nuts M8: 8 Nm Plastic screw connections: 18 Nm Miscellaneous: Use screw connections which make an easy exchange of the manifold possible. Close not connected manifold circuits with plugs or caps. Additionally the valve of the supply module and the flowmeter of the return module have to be closed completely. The connected pipes at the manifold circuit may not exert permanent tensile or pressure load on the manifold. The manifold circuits are rotatable 180 against each other. Page 20

21 -Multipurpose manifold 5000 KST - Flowmeter The hydraulic balancing: The individual circuits can be coordinated and adjusted in that way, that each circuit receives only the volume flow which is necessary for the respective heat or refrigeration capacity. The desired volume flow can be easily and quickly adjusted by the standard integrated flowmeter of the SBK Multipurpose manifold. Procedure: System has to be completely filled and deaerated, operating pressure has to be existent! Close all flowmeters of the return manifold, open all valves of the supply manifold. Adjust volume flow of the first circuit by turning the transparent plastic pipe according to the heat requirement calculation (use handwheel of the supply valve). Indicator pin of the plastic pipe rises upward. Turn plastic pipe as far as the indicator pin indicates the desired value. Balance next circuit as aforementioned. Put the handwheel from the supply module on the flowmeter and adjust the desired water quantity by turning Protect hydraulic balancing against unauthorized adjusting Close flowmeter with cap and provide it with a lead Plastic pipe Indicator pin Tightening torque: 30 Nm Cap Return module Flowmeters with different indicating ranges are available for different flow rates Indicator pin Black Yellow Red Green Marking 1 500l/h 200l/h 100l/h 50l/h Marking 2 800l/h 400l/h 250l/h 100l/h Marking l/h 550l/h 350l/h 150l/h Marking l/h 700l/h 450l/h 200l/h SBK Multipurpose manifold 5000 Return module with integrated flowmeter Marking l/h 1050l/h 600l/h 250l/h Values apply to medium water, 20 C Page 21

22 -Multipurpose manifold 5000 KST - with integrated screw clamp 1 2 Assembly instructions: 1: Remove the plastic nut 2: Remove the clamp ring from the plastic nut Module with external thread Plastic nut External thread Clamp ring 3 4 3: Push the clamp ring and the plastic nut over the sonde. 4: Push the sonde all the way to the stop into the module. O-Ring Sonde Clamp ring Clamp ring Sonde Plastic nut Plastic nut 5 5: Tighten up the plastic nut only hand-tight. Do not use any tools. Module with external thread Plastic nut Sonde Page 22

23 Page 23

24 Terms of Sale, Delivery and Payment Fa. SBK 1 Offers, confirmations of order, conclusion of contract 6 Complaints 1.1 No offer is binding. We reserve the right to alter, add to and abandon our 6.1 If defects or damages which are recognized during an orderly incoming production at any time. control, customers must complain immediately on arrival of merchandise. Complaints about defects which cannot be recognized on arrival must be made 1.2 A contract results with our written acceptance of order. The contents of the immediately when found. Every claim for guarantee is lost, however, 5 years after order acceptance are also the contents of the contract, as long as the customer delivery. does not object to the contract immediately after receiving it. Otherwise, our confirmation of order applies and our general terms of sale, delivery and payment 6.2 Whether quantity or amount in weight, discrepancies are to be queried at the are approved. rail or forwarding company (haulage contractors), on receiving the merchandise and written confirmation of the difference is to be obtained. Defective items are to 1.3 The issued order cannot be changed or cancelled after the sending of the be sent immediately, freight-free and postage-free. order confirmation. 1.4 The terms of sale, delivery and payment in hand have priority in every case 7 Guarantee over future purchase terms of our customers. 7.1 We undertake a guarantee for our water manifold 4001, multipurpose manifold 5000 and distribution manifold 3000 / 2000 / 1000 of five years. We not 1.5 The price is ex works and without turnover tax (VAT). undertake the guarantee for other delivered items by us. 1.6 Increases in costs between the order confirmation and delivery entitle us to appropriate price adjustments. 8 Sales Return 8.1 In the case of sending backs of deliveries to us which are not justifiable, we will calculate processing costs. At least 10 % of the invoiced value of delivery. 2 Conditions of Payment Sending backs can only occur with our consent explained expressly first. The 2.1 Outside of Germany 100 % of the invoice amount when the goods are ready items in original packing returned with our consent have to be in a marketable for dispatch on our premises. condition. 2.2 If there are delays in payment, we are entitled to charge interest payable on arrears, at 4 % over the prevailing bank rate, however, at least 10 % p. a. Only 9 Delays in delivery and release from delivery obligation payments made to the corresponding place of payment, stated in the invoice, are 9.1 The obligation of delivery as well as compliance with keeping within delivery recognized when the sum of the invoice is irrevocably credited to our account. date will be revoked by all conditions which are exceptional and for which we are not liable. This is also the case when business is interrupted or the sending of the 2.3 The date of the invoice is relevant for date of payment in all cases, even if the goods is made impossible due to these conditions. recipient receives the merchandise after the delivery date due to reasons for which we are not responsible. 9.2 If we are in delay with the delivery, the purchaser must grant an appropriate extension of at least six weeks. The purchaser does not have the right to cancel a 2.4 Passing the date of payment or entry into lack of credit standing of the party contract, also not after granting extension of time, if we have already started with ordering as well as other important reasons entitle us to cancel the contract without a claim for performance and compensation against us, through this, being justified. 3 Retention of Property 3.1 The delivered merchandise remains our property until complete payment is received. Our right of property affects the proceeds procured by the purchaser in case of alienation. The purchaser must inform his customer about the existing retention of property for further alienation. 3.2 The purchaser must inform us immediately, if third party claims are made for the delivered merchandise or rights constituted. Miscellaneous prosecution costs are carried by the purchaser. the production of the ordered goods. 10 Failure to deliver 10.1 Failure to deliver cannot be judged according to the situation of single items. 11 Claims for damages, limitation of the guarantee 11.1 All claims which are made for and apply to the title of guarantee or a miscellaneous claim for damages against us, are limited to the amount of the net factor value of the appropriate object We have the right to replace miscellaneous claims for guarantee by supplying equivalent parts. This does not entitle the customer to claim a price reduction. 4 Forwarding and Packaging 11.3 Claims for damages due to installation, maintenance and instruction costs 4.1 Place of contract performance is the company s location in Neuenstein etc. will not be recognized or remunerated by us. (Germany) We accept no liability of any kind for damage which is caused to persons or 4.2 Deliveries are freely to destination within german customs frontier from euro objects by the use or installation of products, also damaged ones, delivered by 750,00 and more, inclusive wrapping. us. We are also not liable for damages which are caused during improper use, installation, overuse or natural wear and tear. 4.3 Forwarding is carried out ex works Neuenstein at the risk of the ordering party, also by freight-free delivery. 12 Place of contract performance, court of jurisdiction 4.4 The seller is only obliged to take out an insurance if and as far as this has been 12.1 Place of contract performance is Neuenstein (Germany). Court of agreed in writing. jurisdiction is the competent court of jurisdiction in Heilbronn (Germany) without any exception. 5 Changes of Models 5.1 We reserve the right to change constructions, tolerances and improvements. 5.2 We reserve the right to a reduction of or an addition to the delivery by 5 % of the quantity ordered for specially produced products which are made according to a sample, model or drawing. Page 24 Page 24

Hotline for orders/information. aeritool.de / Aeration tools effective from For a healthy and beautiful turf

Hotline for orders/information. aeritool.de / Aeration tools effective from For a healthy and beautiful turf aeritool.de Hotline for orders/information +49 152 / 33 67 9582 Aeration tools effective from 01.01.2019 For a healthy and beautiful turf About Us Aeritool GmbH was founded in 2010 and can look back on

More information

RIA - VAC SYSTEM PROAGRIA Landbrug A/S Aggershusvej 7 Tlf: DK-5450 Otterup Fax:

RIA - VAC SYSTEM PROAGRIA Landbrug A/S Aggershusvej 7 Tlf: DK-5450 Otterup Fax: RIA - VAC SYSTEM RIA - VAC ASSEMBLY-DIRECTIONS FOR DN 200-250-300 mm RIA VAC LIQUID MANURE DISCHARGE SYSTEM PLAN LONGITUDINAL SECTION (Pipeline with closure cover) PLAN LONGITUDINAL SECTION (Pipeline with

More information

INDUSTRIAL HAUL AGREEMENT

INDUSTRIAL HAUL AGREEMENT INDUSTRIAL HAUL AGREEMENT PUBLIC WORKS MEMORANDUM OF AGREEMENT entered into this day of, A.D., 20(yr). BETWEEN: PARKLAND COUNTY a County incorporated under the laws of the Province of Alberta, (hereinafter

More information

MECHANICAL SECTIONS TRAINING EQUIPMENT MADE IN ITALY

MECHANICAL SECTIONS TRAINING EQUIPMENT MADE IN ITALY MECHANICAL SECTIONS TRAINING EQUIPMENT MADE IN ITALY Index FLUID MECHANICS & REFRIGERATION INDUSTRIAL WATER PUMPS/TURBINES AND ACCESSORIES - CUTAWAY....170-179 Water pumps.... Valves.... Motor pumps....

More information

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA Installation and operating instructions Solar charge controller 10 A / 15 A / 0 A / 30 A EN 74.86 08.4 1. About this manual These operating

More information

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev Patent No. 6520259 Installation Manual P/N 95232 Rev 6-16-11 Table of Contents ing Extraction Inlets track changing water levels to maintain optimum performance 1.Component Identification Page 1 2. How

More information

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components 7EN www.caleffi.com Circulation units for solar thermal systems Copyright Caleffi 7HE - 79HE series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Product range Technical specifications Characteristic

More information

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442) Single-Position Detent Clutch DC Series (i) FORM NO. L-2017-A-001 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject

More information

USE AND MAINTENANCE MANUAL. J-Giotto-Top GB-IST-JGIOT-0112

USE AND MAINTENANCE MANUAL. J-Giotto-Top GB-IST-JGIOT-0112 USE AND MAINTENANCE MANUAL J-Giotto-Top GB-IST-JGIOT-0112 Table of Contents 1. Symbols used...3 2. Safety instructions...3 3. Structure and functions of J-Giotto Top...4 4. Technical data...5 5. Installation...7

More information

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive Installation and Operation Instructions VAG ROTOP Portable Electric Drive KAT-B 5551 Edition 1-01/2018 Content 1 General 3 1.1 Safety 3 1.2 Proper use 3 2 Transport and Storage 3 2.1 Transport 3 2.2 Storage

More information

English. Instruction and operation manual S 212. Dew point sensor

English. Instruction and operation manual S 212. Dew point sensor English Instruction and operation manual S 212 Dew point sensor Dear Customer, thank you for choosing our product. The operating instructions must be read in full and carefully observed before starting

More information

PVI 60KW, PVI 82KW, PVI 95KW

PVI 60KW, PVI 82KW, PVI 95KW PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy

More information

HERZ-Motorised flow controler

HERZ-Motorised flow controler HERZ-Motorised flow controler Control and regulating valve Data sheet 4006 SMART, Issue 0516 Dimensions in mm 4006 M 4006 R M R Order number DN G L L1 B B1 H without Actuator H with Actuator H1 1 4006

More information

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter

More information

SGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement

SGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement SGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement This Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement (the Agreement ) is entered

More information

RSPO PalmTrace - Book and Claim Terms and Conditions

RSPO PalmTrace - Book and Claim Terms and Conditions 1. Introduction 1.1 The Roundtable on Sustainable Palm Oil ( RSPO ), a non-profit association registered in Switzerland under Swiss law, supports the following supply chain models for the uptake of certified

More information

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria

More information

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP TM 42371 Avenida Alvarado Temecula, CA 92590 TOLL FREE (800) 454-2725 TEL (951) 296-3480 FAX (951) 296-3490 www.aquauv.com Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP Sunami Warranty

More information

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications 28237 www.caleffi.com Circulation units for solar thermal systems Copyright 204 Caleffi 278-279 series INSTALLATION AND COMMISSIONING MANUAL CONTENTS Function Important Product range Technical specifications

More information

Installation instruction Sound Booster Pro Active Sound

Installation instruction Sound Booster Pro Active Sound Version 1.03 (20.04.2016) Installation instruction Sound Booster Pro Active Sound Article no. 40180 Audi A6 4G Audi A7 4G Audi Q5 8R www.kufatec.de Kufatec GmbH & Co. KG Dahlienstr. 15 23795 Bad Segeberg

More information

Price List. Catalog Eleven. Rigging. Effective February 16, Specialties Inc. manufacturer of stage equipment

Price List. Catalog Eleven. Rigging. Effective February 16, Specialties Inc. manufacturer of stage equipment Price List Catalog Eleven Rigging Effective February 16, 2015 & manufacturer of stage equipment (626) 575-0776 14850 Don Julian Road, Suite B (800) 221-9995 City of Industry CA 91746 www.hhspecialties.com

More information

TERMS AND CONDITIONS OF SUPPLY

TERMS AND CONDITIONS OF SUPPLY TERMS AND CONDITIONS OF SUPPLY 1.0 Interpretation 1.1 In these terms and conditions, these meanings apply unless the contrary intention appears: "Australian Consumer Law" means the Australian Consumer

More information

BYD B-Box Limited Warranty Letter

BYD B-Box Limited Warranty Letter BYD B-Box Limited Warranty Letter Applicable Country: Australia Effective date: 01 st, Jul., 2017 BYD B-Box System Applicable product types: B-Box H 6.4 / B-Box H 7.7 / B-Box H 9.0 / B-Box H 10.2 / B-Box

More information

Product range Solex Technical data and dimensioning. 5 Years

Product range Solex Technical data and dimensioning. 5 Years Qualität made in Germany Product range Solex Technical data and dimensioning Quality made in Germany 5 Years Handwerkergarantie m anufacturer s warranty Product range Solex Dimensioning High-Flow system

More information

Globe Control Valve Series 1a

Globe Control Valve Series 1a Maintenance Globe Control Valve Series 1a are subject to alteration without notice. The text and illustrations do not necessarily display the scope of supply or any ordering of spare parts. Drawings and

More information

Price list april 2015

Price list april 2015 Price list april 2015 radiator model total height dimensions in mm pipe centres depth length ø connections heat output EN 4 T C Watt Kcal/h. white section special coloured section GL / 890 183 158 23,60

More information

Hydraulic Fittings. Design, Manufacture, Distribution

Hydraulic Fittings. Design, Manufacture, Distribution Hydraulic Fittings Design, Manufacture, Distribution Hydraulic Fittings are exclusively distributed by Beaumanor Engineering Ltd of Leicester and manufactured by Balu Auto Components of Chennai India,

More information

Miniature Shock Absorbers SC²25 to SC²650 Self-Compensating

Miniature Shock Absorbers SC²25 to SC²650 Self-Compensating Miniature Shock Absorbers SC²25 to SC²650 Self-Compensating 1 SC25EUM-5 SC25EUM-6 SC25EUM-7 SC75EUM-5 SC75EUM-6 SC75EUM-7 SC190EUM-5 SC190EUM-6 SC190EUM-7 SC300EUM-5 SC300EUM-6 SC300EUM-7 SC300EUM-8 SC300EUM-9

More information

INSTALLATION MANUAL. Installation Details Warranty Wolfen Folding Shower Seat 600mm Wolfen Folding Shower Seat 960mm

INSTALLATION MANUAL. Installation Details Warranty Wolfen Folding Shower Seat 600mm Wolfen Folding Shower Seat 960mm INSTALLATION MANUAL 9505996 Wolfen Folding Shower Seat 600mm 9505997 Wolfen Folding Shower Seat 960mm Installation Details Warranty Delivering unrivalled quality Designed for absolute performance, Wolfen

More information

Mikrotherm F. Manual Radiator Valves With presetting

Mikrotherm F. Manual Radiator Valves With presetting Mikrotherm F Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm F Mikrotherm F The Mikrotherm F manual radiator valve is used in warm water pump heating

More information

Nira 6B Hand Pump. Instruction and Maintenance Manual

Nira 6B Hand Pump. Instruction and Maintenance Manual Nira 6B Hand Pump Instruction and Maintenance Manual Copyright Nira Pumps Oy, 2018 3/2018 2 Contents 1 Nira 6B... 4 2 Use... 5 2.1 Before using... 5 2.2 Installation... 5 2.3 Using the pump... 5 3 Maintenance...

More information

three-way mixing valve

three-way mixing valve three-way mixing valve with or without presetting, for heating and cooling systems. Pressurisation & Water Quality alancing & Control Thermostatic Control engineering avantage Three-way mixing valve, with

More information

Product catalogue Tyre pressure technique

Product catalogue Tyre pressure technique Product catalogue Tyre pressure technique HORN GmbH & Co. KG The HORN GmbH & Co. KG has been founded in 1944 by Ernst Horn. HORN has been since decades a well-known brand name on the German and European

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS TURBO-LUX 3 Orifice Plate Flowmeter FM, LPCB and VdS approved IMPRINT All rights reserved. Any reproduction or usage without written authorisation of MECON GmbH - even partial content

More information

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8 2P050-3/8F

More information

3V SERIES SOLENOID VALVE

3V SERIES SOLENOID VALVE 3V110-410 SERIES SOLENOID VALVE Valve Model 3V110-1/8 3V210-1/4 3V310-3/8 3V410-1/2 Port & Mounting Action & Motion Operating Pressure Body Ported Air Pilot, Spool Design, Response Time

More information

PUSH BUTTON KEY CABINET

PUSH BUTTON KEY CABINET PUSH BUTTON KEY CABINET Model 95689 INSTALLATION And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd.,

More information

Safety Shock Absorbers SCS33 to SCS64

Safety Shock Absorbers SCS33 to SCS64 Safety Shock Absorbers SCS33 to SCS64 1 Operating Instruction SCS33-25EU SCS33-50EU SCS45-25EU SCS45-50EU SCS45-75EU Rod Button SCS64-50EU SCS64-100EU SCS64-150EU Integrated Rod Seals Main Bearing Content

More information

Fortis Wind Energy dealer price list

Fortis Wind Energy dealer price list Fortis Wind Energy dealer price list 2009-1 DELIVERY CONDITIONS All orders are subject to our General Conditions of Sale, please read the last pages of this price list. Prices are F.C.A. Groningen in Euro

More information

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES V5000 Kombi-3-plus RED V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES CONTENTS PRODUCT DATA Overview... 2 Design... 2 Materials... 2 Application... 2 Features... 2 Specifications... 2 Ordering

More information

80% Max working pressure: Max working temperature: 70 C. Flow-meter regulation range: Flow meter-regulation range: ± 10%

80% Max working pressure: Max working temperature: 70 C. Flow-meter regulation range: Flow meter-regulation range: ± 10% Luxor s distribution manifolds are from brass bar CW617N. The manifolds are tooled and produced with fully automated machineries and tested when complete with their accessories to guarantee their absolute

More information

WEB CONTROL PRODUCTS

WEB CONTROL PRODUCTS WEB CONTROL PRODUCTS User Manual MB Tension Sensor (i) FORM NO. L-20127-G-0501 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual

More information

Installation Instructions RFK VW Amarok

Installation Instructions RFK VW Amarok Version 1.04 (09.06.2015) Installation Instructions RFK VW Amarok Articlenr. 38352 VW Amarok www.kufatec.de Kufatec GmbH & Co. KG Dahlienstr. 15 23795 Bad Segeberg e-mail: info@kufatec.de Content Copyright...

More information

MAX. LOAD ALLOWABLE WIRE ROPE. Catenary wire festoon systems for Ø6 and Ø8mm 5 KG

MAX. LOAD ALLOWABLE WIRE ROPE. Catenary wire festoon systems for Ø6 and Ø8mm 5 KG WIRE ROPE MAX. LOAD ALLOWABLE 5 KG DESCRIPTION Catenary wire festoon systems for Ø6 and Ø8mm SERIES 2301 2337 GENERAL SALES CONDITIONS, SUPPLY AND WARRANTY Generalities The supply of the products contained

More information

INTERNATIONAL WARRANTY PROCEDURE. AUTOCLIMA S.p.A. PG-01-05

INTERNATIONAL WARRANTY PROCEDURE. AUTOCLIMA S.p.A. PG-01-05 INTERNATIONAL WARRANTY PROCEDURE AUTOCLIMA S.p.A. PG-01-05 Rev. Rev. date Description/summary of revision 0 01/02/2005 First issue. 1 10/07/2008 First revision. 2 04/09/2014 Second revision. 3 20/03/2015

More information

In this booklet you will find the full range of Hatco wheel balancing weights, the prelude Hatco product.

In this booklet you will find the full range of Hatco wheel balancing weights, the prelude Hatco product. Since 1984 Hatco has grown to become one of the most prominent tire repair and consumables manufacturers. One of its kind in Lebanon, and via continuous development for best quality, Hatco aims "at becoming

More information

In-Line Linear Actuator

In-Line Linear Actuator In-Line Linear Actuator Operating Instructions 12 Volt DC Input Australian Gas Springs - LiftEasy Actuators Address: 29 Tower Court Noble Park Victoria 3174 Australia Telephone: +61 3 9769 0288 Fax: +61

More information

4V130P-430P SERIES AIR PILOT VALVE

4V130P-430P SERIES AIR PILOT VALVE 4V130P-430P SERIES AIR PILOT VALVE Valve Model 4V130P-1/8 4V230P-1/4 4V330P-3/8 4V430P-1/2 Port & Mounting Action & Motion Operating Pressure Body Ported Double Solenoid, Spool Design, 3 Position, Pressure

More information

PEAK LOAD CAPACITY AGREEMENT XXXX/2017. Customer Oy. and. Finextra Oy

PEAK LOAD CAPACITY AGREEMENT XXXX/2017. Customer Oy. and. Finextra Oy UNOFFIAL TRANSLATION PEAK LOAD CAPACITY AGREEMENT XXXX/2017 Customer Oy and Finextra Oy 2 (5) Contents 1 PURPOSE OF THE AGREEMENT... 3 2 VALIDITY OF THE AGREEMENT... 3 3 PEAK LOAD CAPACITY FEE AND ITS

More information

FCB-450, LCB-600, MCB-800

FCB-450, LCB-600, MCB-800 AIR CHAMP PRODUCTS User Manual FCB-450, LCB-600, MCB-800 Clutch-Brakes (i) In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are

More information

C. Biotec 30. Gebrauchsanweisung Directions for use Mode d emploi Gebruiksaanwijzing

C. Biotec 30. Gebrauchsanweisung Directions for use Mode d emploi Gebruiksaanwijzing 29739-06C Biotec 30 Gebrauchsanweisung Mode d emploi Gebruiksaanwijzing 1 Direction for use Product description Biotec 30 is a multi-zone filter for large ponds up to 130 m³, or up to 65 m³ for fish ponds.

More information

STC 2W Series Solenoid Valves

STC 2W Series Solenoid Valves STC 2W160-500 Series Solenoid Valves 2W160-500 Series Solenoid Valve Specifications Valve Model 2W160-3/8 2W160-1/2 2W200-3/4 2W250-1 2W350-1 1/4 2W400-1 1/2 2W500-2 Valve Type Action 2 Way, Normally Closed

More information

BYD B-Box Limited Warranty Letter

BYD B-Box Limited Warranty Letter BYD B-Box Limited Warranty Letter Applicable Country: Germany Effective date: 01 st, Jan., 2017 BYD B-Box System Applicable product types: B-Box Pro 2.5 / B-Box Pro 5.0 / B-Box Pro 7.5 / B-Box Pro 10.0

More information

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators. Data sheet Flow and temperature controller with / without integrated control valve (PN 25) AVQT - flow and temperature controller AVQMT - flow and temperature controller with integrated control valve Description

More information

Siemens AG Modern design and easy handling for charging at home or in the semi-public area

Siemens AG Modern design and easy handling for charging at home or in the semi-public area s Drivergy WB140A charging unit Modern design and easy handling for charging at home or in the semi-public area Easy charging at home WB140A charging unit: Modern, functional design and easy handling combine

More information

flexible infrared thermometer

flexible infrared thermometer flexible infrared thermometer Model 94233 assembly and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result

More information

TITAN 13 x 2½ BRAKES DUO-SERVO AND FREE BACKING

TITAN 13 x 2½ BRAKES DUO-SERVO AND FREE BACKING INSTALLATION INSTRUCTION AND SERVICE MANUAL Actuator/Trailer Dealer - Please provide these instructions to the consumer. Consumer - Read and follow these instructions. Keep them with the trailer for future

More information

Comprehensive Hydraulic Rescue System Inspection and Maintenance Agreement Revision 1 Effective 1/1/2010

Comprehensive Hydraulic Rescue System Inspection and Maintenance Agreement Revision 1 Effective 1/1/2010 113 North Griffith Rd. P.O. Box 625 Carroll, Iowa 51401 Phone: 712-792-3143 Fax: 712-792-6658 WATS: 1-800-568-2403 E-mail: sales@feldfire.com Website: www.feldfire.com Member: NFPA, NAFED, I.A.F.C., I.F.A.,

More information

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs HERZ 7217 V Integral Fixed Orifice Control Valve Data sheet 7217 V, Issue 1011 Size in mm STRÖMAX Fig No DN L Lm Rp H SW kv kvs TS-V LF 1 7217 50 15 83 28,5 1/2 41 27 0,07-0,45 0,48 TS-V MF 1 7217 59 15

More information

PREMIER, MARINE, & STANDARD

PREMIER, MARINE, & STANDARD INSTA LLATION INSTRUCTION AND SERVICE MANUAL I TITAN 12" x 2" BRAKES FREE BACKING. UNI-SERVO. DUO-SERVO PREMIER, MARINE, & STANDARD Limited Warranty TITAN Inc. ("TITAN') warrants its products to be free

More information

via manzoni collection

via manzoni collection V I A M A N Z O N I via manzoni collection P R I C E L I S T Via Manzoni di Emporio Gessi è un rubinetto di design a tecnologia eco-sensibile. Quando la leva del miscelatore è in posizione centrale, il

More information

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO MEX (55) 5 6 QRO (44) 95 7 60 MTY () 54 0 BC Brake Caliper (i) FORM NO. L-0066-B-040 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this

More information

STC 2L Series Solenoid Valves

STC 2L Series Solenoid Valves STC 2L170-500 Series Solenoid Valves 2L170-500 Series Solenoid Valve Specifications Valve Model 2L170-3/8 2L170-1/2 2L170-3/4 2L200-1 2L300-1 1/2 2L500-2 Valve Type Action 2 Way, Normally Closed (NC) Pilot

More information

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual Reach ins, Freeezers & Refrigerators Installation & Operation Manual BSR23 BSF23 BSR49 BSF49 BSR72 BSF72 IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) Visit us on the web at www.blueairinc.com

More information

Pressure independent balancing and control valve

Pressure independent balancing and control valve Pressure independent balancing and control valve AB-QM DN 10-150 AB-QM valve equipped with an actuator is a control valve with full authority and automatic balancing function - flow limiter. Typical applications

More information

BC Brake Caliper 1 FORM NO. L D-0414

BC Brake Caliper 1 FORM NO. L D-0414 BC Brake Caliper FORM NO. L-0066-D-044 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject to change without notice. Technical

More information

AIR CHAMP PRODUCTS. User Manual. DAP-625S and DAP-875S FORM NO. L D-0914

AIR CHAMP PRODUCTS. User Manual. DAP-625S and DAP-875S FORM NO. L D-0914 AIR CHAMP PRODUCTS User Manual DAP-65S and DAP-875S FORM NO. L-0078-D-09 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject

More information

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414 AIR CHAMP PRODUCTS User Manual Sheave & Pilot Mount Clutch-Brake Model BCB-275 i In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual

More information

Note: it is a criminal offence to give false information in this application.

Note: it is a criminal offence to give false information in this application. Note: it is a criminal offence to give false information in this application. Section 1 - Your contact details (Please read Guidance Note 1) 1a) Please give full details of the person that can be contacted

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTION AND SERVICE MANUAL Actuator/Trailer Dealer - Please provide these instructions to the consumer. Consumer - Read and follow these instructions. Keep them with the trailer for future

More information

LIIKENNEVIRTA LTD GENERAL TERMS AND CONDITIONS FOR THE CHARGING SERVICE

LIIKENNEVIRTA LTD GENERAL TERMS AND CONDITIONS FOR THE CHARGING SERVICE 1 (7) LIIKENNEVIRTA LTD GENERAL TERMS AND CONDITIONS FOR THE CHARGING SERVICE 1 Scope of application and definitions 1.1 These General Terms and Conditions pertaining to the delivery of the Charging Service

More information

Operating manual for

Operating manual for Operating manual for automaticspray valve ASV Read this manual carefully before installing, operating or servicing this equipment. Keep always handy for further use. ALFRED SCHÜTZE Apparatebau GmbH - Spritztechnik

More information

VOLUMETRIC FILTER MODELS T450 T500 T600 T700 T600B T700B

VOLUMETRIC FILTER MODELS T450 T500 T600 T700 T600B T700B VOLUMETRIC FILTER MODELS T450 T500 T600 T700 T600B T700B IMPORTANT SAFETY INSTRUCTIONS Read and follow all instructions in this owner s manual and on the equipment. Failure to follow instructions can cause

More information

Feb 22, 2018 '67-69 Camaro & '68-74 Nova Bumpsteer Adjustment Kit

Feb 22, 2018 '67-69 Camaro & '68-74 Nova Bumpsteer Adjustment Kit Feb 22, 2018 '67-69 Camaro & '68-74 Nova Bumpsteer Adjustment Kit 10552 The following instructions are intended for professional installers. Speedtech Performance assumes NO responsibility for the installation

More information

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Type 3535 Three-way Valve with bellows seal and rod-type yoke (partial view) Mounting and Operating Instructions EB 8135/8136 EN Edition

More information

Insulatet lightning protection

Insulatet lightning protection Insulatet lightning protection Please ask for our special catalogue. 55 systems In recent years, the roof top installation of electronically controlled equipment, such as air conditioning systems, ventilation

More information

USE AND MAINTENANCE INSTRUCTIONS. Giotto-Top GB-IST-GIOT-0112

USE AND MAINTENANCE INSTRUCTIONS. Giotto-Top GB-IST-GIOT-0112 USE AND MAINTENANCE INSTRUCTIONS Giotto-Top GB-IST-GIOT-0112 INDEX 1. Symbols used...3 2. Safety instructions...3 3. Structure and functions of Giotto Top...4 4. Technical data...5 5. Installation...7

More information

Cabinet Hardware LIST PRICES. effective January 1, 2008

Cabinet Hardware LIST PRICES. effective January 1, 2008 2008 2007 2 0 0 8 Cabinet Hardware LIST PRICES effective January 1, 2008 TERMS Unless otherwise mutually agreed upon in writing, Seller s terms for all products sold are Net 10th End of Month. All invoices

More information

INSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler

INSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler INSTALLATION MANUAL 252418 Wolfen 122 Wall Bubbler 252465 Wolfen 90 Wall Bubbler 252419 Wolfen Hob Bubbler 252420 Wolfen Remote Button Bubbler Installation Details Warranty CONTENTS Intro 03 Technical

More information

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX 900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump. Part # AF-03-326 2015 Pentair Ltd. 01/30/15

More information

TERMS AND CONDITIONS OF PARKING AT PALMERSTON NORTH AIRPORT

TERMS AND CONDITIONS OF PARKING AT PALMERSTON NORTH AIRPORT TERMS AND CONDITIONS OF PARKING AT PALMERSTON NORTH AIRPORT 14 December 2017 Palmerston North Airport Limited ( PNAL ) provides travellers and other members of the public with multiple car parking options

More information

STC 2P025 Series Solenoid Valve

STC 2P025 Series Solenoid Valve STC 2P025 Series Solenoid Valve 2P025 Series Solenoid Valve Specifications Valve Model Valve Type Action Cv (Orifice) Operating Pressure Operating Temperature 2P025 2 Way, Normally Closed (NC) Direct Acting

More information

RTL. Floor Heating Controller Return temperature limiter with and without presetting

RTL. Floor Heating Controller Return temperature limiter with and without presetting RTL Floor Heating Controller Return temperature limiter with and without presetting IMI HEIMEIER / Floor Heating Control / RTL RTL Among other things, the return temperature limiter RTL is used to limit

More information

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com FO-BV Series Fixed-orifice balancing and control valves Technical Data Sheet WattsIndustries.com Description FO-BV Series fixed-orifice threaded valves are designed for flow control and monitoring in climate

More information

Raydot LLC 24 Actuator (115 VOLT)

Raydot LLC 24 Actuator (115 VOLT) Installation, Operation & Parts Manual Read carefully the information provided. Retain manual for future reference. Raydot LLC 24 Actuator (115 VOLT) 145 Jackson Ave. S. Cokato, MN 55321-USA (320) 286-2103

More information

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure S T C TM To Order, Please Specify: 1) Model No., 2) Voltage 2 Way, NC Pilot Piston Stainless Steel Part No. Voltage

More information

Wedge-loc Coupler Installation Manual Pin-loc Coupler Installation Manual

Wedge-loc Coupler Installation Manual Pin-loc Coupler Installation Manual Wedge-loc Coupler Installation Manual Pin-loc Coupler Installation Manual Coupler Models SLH1042W, SLH10M, SLH1022H LH2042W, LH3042W, LH4042W, LH5062W, LH6062W LH20M, LH30M, LH40M LH2022H, LH3022H, LH4022H,

More information

Witham (Specialist vehicles) Ltd For sale by Tender - 13th September pm Direct From UK Ministry of Defence

Witham (Specialist vehicles) Ltd For sale by Tender - 13th September pm Direct From UK Ministry of Defence www.mod-sales.com Witham (Specialist vehicles) Ltd For sale by Tender - 13th September 2013 2pm Direct From UK Ministry of Defence Viewing: Wednesday 4th to Friday 13th Sept 2013 (Monday to Friday 8:30am

More information

Content Copyright...1 Disclaimer...2 General Advice...3 Safety Instructions...4 Reference Of Legal Regulations For Operation...4 Hints...5 Scope Of De

Content Copyright...1 Disclaimer...2 General Advice...3 Safety Instructions...4 Reference Of Legal Regulations For Operation...4 Hints...5 Scope Of De Version 1.01 (11.10.2013) Installation Instructions DAB / DAB+ Antenna module Articlenr. 39338 VW Golf 6 www.kufatec.de Kufatec GmbH & Co. KG Dahlienstr. 15 23795 Bad Segeberg e-mail: info@kufatec.de Content

More information

BYD Battery-Box Limited Warranty Letter

BYD Battery-Box Limited Warranty Letter BYD Battery-Box Limited Warranty Letter Applicable Country: Germany Applicable to sales from: 1st, Aug., 2018 BYD Battery-Box System Applicable product types: Battery-Box H 6.4 / Battery-Box H 7.7 / Battery-Box

More information

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves STC 2DS500-2000 Series Anti-Hammering Slow Closing Pilot Solenoid Valves 2DS500-2000 Series Solenoid Valve Specifications Valve Model 2DS400F 2DS500F 2DS650F 2DS800F 2DS1000F 2DS1250F 2DS1500F 2DS2000F

More information

HSIV PLOW OPERATOR S MANUAL

HSIV PLOW OPERATOR S MANUAL PLOW RWF INDUSTRIES 873 Devonshire Ave., Woodstock, Ontario N4S 8Z4 Tel: (519) 421-0036 Toll Free: 1-800-263-1060 Fax: (519) 421-0028 Email: parts@rwfbron.com JANUARY 2015 THE INFORMATION CONTAINED IN

More information

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves Series 250 Type 3252 1 and Type 3252 7 Pneumatic Control Valves Type 3252 High-pressure valve with Type 3277 Pneumatic Actuator and Type 3767 Electropneumatic Positioner Mounting and Operating Instructions

More information

AIR CHAMP PRODUCTS. User Manual. Conveyor Clutch. Model 5H20S/4 FORM NO. L C-0914 FORM NO. L C-0914

AIR CHAMP PRODUCTS. User Manual. Conveyor Clutch. Model 5H20S/4 FORM NO. L C-0914 FORM NO. L C-0914 AIR CHAMP PRODUCTS User Manual Conveyor Clutch Model 5H20S/4 i In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject to

More information

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704 Elgin Hydraulic Clutch-Brake ECB-20, Product Number 96225 FORM NO. L-20283-F-070 1 FORM NO. L-20283-F-070 In accordance with Nexen s established policy of constant product improvement, the specifications

More information

INSTALLATION MANUAL Wolfen Cleaners Sink With Grate. Installation Details Warranty

INSTALLATION MANUAL Wolfen Cleaners Sink With Grate. Installation Details Warranty INSTALLATION MANUAL 9506688 Wolfen Cleaners Sink With Grate Installation Details Warranty Delivering unrivalled quality Designed for absolute performance, Wolfen s cleaners sink sets new standards in quality

More information

YOUR CONTACT WITH ELECTRICITY COMPANIES

YOUR CONTACT WITH ELECTRICITY COMPANIES YOUR CONTACT WITH ELECTRICITY COMPANIES page 2 Electricity options available to you page 4 Your electricity consumption (meter reading facts) page 6 You re moving in (what to do with your contracts) page

More information

INSTALLATION MANUAL. Installation Details Warranty Wolfen Hand Held Trigger Spray Assembly With Stop Tap

INSTALLATION MANUAL. Installation Details Warranty Wolfen Hand Held Trigger Spray Assembly With Stop Tap INSTALLATION MANUAL 252432 Wolfen Hand Held Trigger Spray Assembly With Stop Tap 252444 Wolfen Pre Rinse Slophopper Assembly Without Tap 252431 Wolfen Pre Rinse Trigger Spray Installation Details Warranty

More information

430B SERIES HORIZONTAL SPLIT CASE PUMP

430B SERIES HORIZONTAL SPLIT CASE PUMP 430B SERIES TWO Stage - DIAGONALLY HORIZONTAL SPLIT CASE PUMP REPAIR PARTS INDEX NOTE! Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump.

More information

INSTALLATION INSTRUCTIONS TOP MOUNT SINKS

INSTALLATION INSTRUCTIONS TOP MOUNT SINKS These instructions are for installing top mount stainless steel sinks. (CH365 and CH366 NOT included) Please read all instructions carefully before starting the installation. TABLE OF CONTENTS Preparation

More information