1 Operated Pumps Liqui-Mover pump products Non-electric positive displacement pumps. The more reliable and efficient way to move liquids.

2 Liqui-Mover Pumps Kadant Johnson has been manufacturing the Liqui-Mover pump since The Liqui-Mover pump performs the same function as a conventional electric centrifugal pump. However, it is based on a different operating concept and has fewer moving parts than a conventional electric pump. The Liqui-Mover pump is a positive displacement pump and has no motors, starters, rotating mechanical seals, or impeller. Instead, the Liqui-Mover pump uses steam (or other compatible inert gas) as the motive pressure to lift or pump liquids. Liqui-Mover pumps have few temperature limitations, unlike conventional electric pumps. Many conventional pumps are limited to liquid temperatures of 200 F. Because of the Liqui-Mover pump s high temperature capabilities, flashing valuable heat energy to atmosphere or adding additional cooling equipment can be eliminated, increasing system reliability and reducing installation and equipment costs. Due to their simple design and compact dimensions, Liqui-Mover pumps are easy to integrate into new and existing systems. They are easy to install and may require only a single trade to install. Models are available as a packaged unit (LRSM model) ready for direct hook-up to plant piping. The Liqui-Mover pump is available with a non-electric float or a float-free level control with capacities up to 180,000 pph (360 gpm). Operated Liqui-Mover Pumps u No electricity u No motors, starters, seals, or impellers u Good for general, wet, and explosive environments u Proven system reliability u Capacities up to 14,900 pph (30 gpm) for simplex pump u 150 psig ASME labeled steel tanks standard (higher ratings available) u Modular construction available for ease of installation u Pump and PumpTrap models available u Custom designs and configurations u Available with or without receiver, simplex or multiplex pumps, alarms, cycle counter, and insulation u Upgrade retrofit mechanisms available to replace competitor s drop-in float mechanisms Free Liqui-Mover Pumps u No springs to fail u No floats to collapse u No pivot points or linkage to wear u Proven system reliability u Capacities up to 180,000 pph (360 gpm) u 150 psig ASME labeled steel tanks standard (higher ratings available) u Modular construction available for ease of installation u Pump and PumpTrap models available u Custom designs and configurations u Available with or without receiver, simplex or duplex pumps, stand-by motive valve, alarms, cycle counter, and insulation u Free retrofits available to replace your drop-in float mechanisms 2

3 Choosing the Best Pump for Steam Condensate Service What to look for u Ability to handle high temperature condensate and flash steam u Energy efficiency u Service requirements and availability u Low maintenance requirements u Proven performance reliability How Does It Measure Up? Electric Condensate Pump Liqui-Mover Condensate Pump u Temperature limit of 200 F Yes No u Energy efficiency Sized with 3:1 safety factor Sized for actual incoming load u Condensate cooling Yes No u Zero flash system No Yes u Electric required Yes No u Maintenance requirements Seal kits, motors, float switches, impellers High maintenance items eliminated Condensate from elevated steam users Vent line Condensate from steam users Vent line Steam traps Electric condensate pump Electrical voltage supply Steam traps Receiver/Pipe header LMHT-500 Condensate discharge Condensate discharge Electric Condensate Pump Liqui-Mover Condensate Pump 3

4 Operation series Liqui-Mover pumps The float series Liqui-Mover pump moves condensate and other fluids using steam or other inert gases under pressure without motors, pumps, rotors, or electricity. Stage 1: stage Stage 2: Pump stage Stage 3: Equalize stage A E G E D C B H F D Fluid flows from the receiving chamber (A) through an inlet check valve (B) into the pump tank (C), raising a float (D). The vent port (E) is open to equalize pressure between the receiving chamber and pump tank. When the float reaches its highest level, it triggers a linkage (F) that closes the vent port and opens the motive pressure valve (G) to admit the motive pressure into the pump tank. The motive pressure forces the fluid past the discharge check valve (H) and out the discharge line. Once the float (D) reaches its lowest position, the linkage shuts off the motive pressure port, and opens the vent port (E). Excess pressure is vented to the receiver, equalizing pressure between the two tanks. The cycle will now repeat. Types of systems Condensate inlets Vent to atmosphere Equalize line Make-up steam valve Condensate inlet VB AV To low pressure steam system Equalize line Condensate inlet VB AV Equalize line Receiver tank Motive supply Receiver tank Motive supply Receiver tank Motive supply LMV Liqui-Mover pumping tank LMV Liqui-Mover pumping tank Trap (when required) LMV Liqui-Mover pumping tank Trap (when required) Discharge Discharge Discharge Open system An open system is intended for use with mixed return pressures, this design requires no supplemental cooling of condensate. Flash system A flash system is for applications requiring flash steam such as high pressure processing equipment the receiver in this design acts as a flash tank. Closed system A closed system is for single steam users. There is no BTU energy loss from flashing. 4

5 Pump Selection Guide Model Maximum Capacity (pph) Check Valve Size PMA (psig) TMA ( F) Pump Body Material Level Control Page Number LMHT-500 Low Profile Series 2,830 1" x 1" ASTM A395 Class 60 ductile iron 6 4,070 1" x 1" 150* 650 *Fabricated steel 150 psig ASME U stamped LMHT-1600 Low Profile Series 8, /2" x 1-1/2" 150* ,630 2" x 2" 150* 650 *Fabricated steel 150 psig ASME U stamped *Fabricated steel 150 psig ASME U stamped 8 14,900 3" x 2" 150* 650 *Fabricated steel 150 psig ASME U stamped 3,500 1" x 1" 150* 650 *Fabricated steel 150 psig ASME U stamped 6, /2" x 1-1/2" 150* 650 *Fabricated steel 150 psig ASME U stamped LMV-1600 Series 10 9,260 2" x 2" 150* 650 *Fabricated steel 150 psig ASME U stamped 14,370 3" x 2" 150* 650 *Fabricated steel 150 psig ASME U stamped * Consult factory for other pressure vessel ratings and materials. Above capacities are based on: u Single pump tank u Steam as motive pumping pressure u Maximum fill head u Motive pressure being 20 psig higher than static back pressure u 210ºF condensate temperature 5

6 LMHT-500 Series Low profile, high pressure 19-7/16" 4-13/16" 6-1/16" 3/4" NPT vent connection 1" 1" Vent 3/4" NPT Motive 1/2" NPT 1/2" NPT motive pressure inlet Material specifications Part Pumping tank Material ASME rated 200 psig Tank top and bottom ductile iron SA-395 CL 60 SHCS carbon steel SA-574 1/2" NPT for cycle counter or pressure gauge assembly Level gauge (optional) mechanism Support frame ductile iron SA-395 with nitride surface, valves, springs, and linkage stainless steel 15-1/8" 1-5/8" Check valves As specified 1" NPT inlet / outlet connection Gauge glass Bronze valves with redline glass and brass guard rods 3-1/2" withdrawal height 14-5/16" Check valve options Inlet Outlet Swing Swing Swing Lift Swing Non-Slam Non-Slam Non-Slam Available options u Cycle counter u Level gauge glass u Pressure gauge u Drain piping u Insulation jacket u ASME labeled receiver/reservoir 1/2" NPT drain connection Features u Low profile design u Ductile iron tank u Capacity up to 3,000 pph u Single check valve connection Benefits u Compact installation u High pressure, long operating life u Ideal for light load applications u Fast and reliable installation 6 Note: Dimensions listed are for reference only. Engineering drawings are available on request.

7 LMHT-500 sizing chart Total Static Back Pressure Head 6" Head 12" Head 18" Head 24" Head 24" Head 36" Inlet Check: 1" Swing Inlet Check: 1" Swing Inlet Check: 1" Swing Inlet Check: 1" Swing Inlet Check: 1" Non-Slam Inlet Check: 1" Non-Slam pph GPM pph GPM pph GPM pph GPM pph GPM pph GPM 10 1, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , Note: For multiple pumps, multiply above capacities by the number of pumps. Capacities based on motive steam pressure being 20 psig higher than total static back pressure. Total static back pressure equals vertical lift plus return line pressure. head is the distance from top of pump tank to bottom of receiver/reservoir. Swing inlet check valves are bronze with teflon disc used up to 24" fill head. Stainless steel inlet check valves are spring assist NOT for fill head less than 24". Gallons pumped per cycle is 3.4. height (from grade to bottom of receiver/reservoir to achieve desired fill head) Head Height 6" 21" 12" 27" 18" 33" 24" 39 36" 51 Consumption (approximate) Steam 1.5 lb/1000 lb liquid pumped Air 0.75 cubic feet/cycle D Inlet Receiver/Reservoir (150 psig ASME labeled) Connections Size A D Inlet (X) Inlet (Y) Outlet Drain Capacity LMH-5 10" 26" 2" 1-1/4" 2" 3/4" 7.5 Gal. LMH-10 14" 37" 2" 2" 2" 3/4" 22.5 Gal. LMH-20 18" 35" 2" 2" 2" 3/4" 34 Gal. LMH-40 18" 47" 3" 2" 3" 3/4" 47 Gal. LMH-50 24" 40" 3" 2" 3" 3/4" 69 Gal. LMH-65 24" 44" 3" 2" 3" 3/4" 76 Gal. LMH " 56" 4" 150# Flg 2" 4" 150# Flg 3/4" 98 Gal. LMH " 66" 6" 150# Flg 2" 6" 150# Flg 3/4" 182 Gal. LMH " 123" 6" 150# Flg 2" 6" 150# Flg 3/4" 340 Gal. A X Y X height Drain Outlet Liqui-Mover pump specification Furnish and install according to plans and manufacturer s specifications the Kadant Johnson Liqui-Mover pump as shown on the drawings. Operation of the pump is by means of a non-electric float level control having all moving parts stainless steel, open coil actuating springs, reinforced stainless steel float, and condensate inlet baffle. Operating components to include 200 psig rated A395 CL 60 ductile iron pump body, inlet and outlet check valves as specified, and snap-acting float level control with no external seals or packing. When specified, a level gauge glass, cycle counter, and insulation jacket are to be furnished. 7

8 LMHT-1600 Series Low profile, high capacity 27" 1" 1" Flow 1/2" NPT for cycle counter or pressure gauge assembly Material specifications Part Pumping tank Material ASME code stamped 150 psig Shell & heads carbon steel SA-414 G Flange ring carbon steel SA-106C 1" NPT vent connection 1/2" NPT motive pressure inlet 3" NPT male inlet Level gauge (optional) mechanism Check valves Mounting flange cast iron SA-278 Support frame ductile iron SA-395 with nitride surface, valves, springs, and linkage stainless steel As specified 22-9/16" 21-1/8" 5-7/16" 3/4" NPT drain connection 15" 2" NPT outlet 4-13/16" (4) 9/16" mounting holes Gauge glass Bronze valves with redline glass and brass guard rods 16" Withdrawal height 7-1/2" Check valve options Inlet Outlet Swing Swing Swing Lift Swing Non-Slam Non-Slam Non-Slam Available options u Cycle counter u Level gauge glass u Pressure gauge u Drain piping u Insulation jacket u ASME labeled receiver/reservoir 13" Features u Low profile design u Capacity up to 15,000 pph u Stainless steel float mechanism u Open coil spring design u Explosion proof Benefits u Compact installation u Large capacity for application flexibility u Wear and corrosion resistant u Greater reliability u Installation flexibility 8 Note: Dimensions listed are for reference only. Engineering drawings are available on request.

9 LMHT-1600 sizing chart Head Total Static Back Pressure LMHT-1610 LMHT-1615 LMHT-1620 LMHT-1632 pph GPM pph GPM pph GPM pph GPM 10 3, , , , , , , , , , , , , , , , " 50 2, , , , , , , , , , , , , , , , , , , , , , , , Check valve size inlet 1" 1.5" 2" 3" Check valve size outlet 1" 1.5" 2" 2" Gallons pumped per cycle Note: Above based on steam as the motive pressure. Capacities based on motive steam pressure being 20 psig higher than total static back pressure. Total static back pressure equals vertical lift plus return line pressure. head is the distance between top of the pump tank to the bottom of the receiver/reservoir. For multiple pumps, multiply above capacity by number of pumps to be used. Consumption (approximate) Steam 3 lb/1000 lb liquid pumped Air 2.5 cubic feet/cycle Capacity conversion factors for other fill heads Head Inlet Check Valve Type LMHT-1610 LMHT-1615 LMHT-1620 LMHT " swing " swing " swing " swing " non-slam " non-slam height (from grade to bottom of receiver/reservoir to achieve desired fill head) Head Height 6" 25" 12" 31" 18" 37" 24" 43" 36" 55" Swing inlet check valve is bronze with teflon disc used up to 24" fill head. Non-slam inlet check valve is spring loaded NOT for fill head less than 24". D Inlet Receiver/Reservoir (150 psig ASME labeled) Connections X Y X Size A D Inlet (X) Inlet (Y) Outlet Drain Capacity LMH-5 10" 26" 2" 1-1/4" 2" 3/4" 7.5 Gal. LMH-10 14" 37" 2" 2" 2" 3/4" 22.5 Gal. LMH-20 18" 35" 2" 2" 2" 3/4" 34 Gal. LMH-40 18" 47" 3" 2" 3" 3/4" 47 Gal. LMH-50 24" 40" 3" 2" 3" 3/4" 69 Gal. LMH-65 24" 44" 3" 2" 3" 3/4" 76 Gal. LMH " 56" 4" 150# Flg 2" 4" 150# Flg 3/4" 98 Gal. LMH " 66" 6" 150# Flg 2" 6" 150# Flg 3/4" 182 Gal. LMH " 123" 6" 150# Flg 2" 6" 150# Flg 3/4" 340 Gal. A Drain Outlet height Liqui-Mover pump specification Furnish and install according to plans and manufacturer s specifications the Kadant Johnson Liqui-Mover pump as shown on the drawings. Operation of the pump is by means of a non-electric float level control having all moving parts stainless steel, open coil actuating springs, reinforced stainless steel float, and condensate inlet baffle. Operating components to include 150 psig ASME labeled steel pump body, inlet and outlet check valves as specified, and snap-acting float level control with no external seals or packing. When specified, a level gauge glass, cycle counter, and insulation jacket are to be furnished. Stainless steel construction and higher pressure ratings also available. 9

10 LMV-1600 Series Vertical profile, high capacity (3) 9/16" mounting holes on 19" B.C. 1/2" NPT for cycle counter or pressure gauge assembly 1" NPT vent connection 1" 1" 17-1/2" Material specifications 1/2" NPT motive pressure inlet Part Material ASME code stamped 150 psig Pumping tank mechanism Shell and bottom head carbon steel SA-414 G Flat head top carbon steel SA Mounting flange cast iron SA-278 Support frame ductile iron SA-395 with nitride surface, valves, springs, and linkage stainless steel 32-7/16" 31" 11-13/16" 3" NPT female (3) places 3/4" NPT drain connection Check valves Gauge glass As specified Bronze valves with redline glass and brass guard rods 16" Withdrawal height 11-1/2" Check valve options Inlet Outlet Swing Swing Swing Lift Swing Non-Slam Non-Slam Non-Slam Available options u Cycle counter u Level gauge glass u Pressure gauge u Drain piping u Insulation jacket u ASME labeled receiver/reservoir Level gauge (optional) Features u Small footprint u Multiple inlet connections u Capacity up to 14,500 pph u Stainless steel float mechanism u Open coil spring design Benefits u Compact installation u Installation and piping flexibility u High capacity units u Wear and corrosion resistant u Greater reliability Note: Dimensions listed are for reference only. Engineering drawings are available on request. 10

11 LMV-1600 sizing chart Head Total Static Back Pressure LMV-1610 LMV-1615 LMV-1620 LMV-1632 pph GPM pph GPM pph GPM pph GPM 10 2, , , , , , , , , , , , , , , , " 50 2, , , , , , , , , , , , , , , , , , , , , , , , Check valve size inlet 1" 1.5" 2" 3" Check valve size outlet 1" 1.5" 2" 2" Gallons pumped per cycle Note: Above based on steam as the motive pressure. Capacities based on motive pressure being 20 psig higher than total static back pressure. Total static back pressure equals vertical lift plus return line pressure. head is the distance between top of the pump tank to the bottom of the receiver/reservoir. For multiple pumps, multiply above capacity by number of pumps to be used. Consumption (approximate) Steam 3 lb/1000 lb liquid pumped Air 1.5 cubic feet/cycle Capacity conversion factors for other fill heads Head Inlet Check Valve Type LMV-1610 LMV-1615 LMV-1620 LMV " swing " swing " swing " swing " non-slam " non-slam height (from grade to bottom of receiver/reservoir to achieve desired fill head) Head Height 6" 35" 12" 41" 18" 47" 24" 53" 36" 65" Swing inlet check valve is bronze with teflon disc used up to 24" fill head. Non-slam inlet check valve is spring loaded NOT for fill heads less than 24". D Inlet Receiver/Reservoir (150 psig ASME labeled) Connections X Y X Size A D Inlet (X) Inlet (Y) Outlet Drain Capacity LMH-5 10" 26" 2" 1-1/4" 2" 3/4" 7.5 Gal. LMH-10 14" 37" 2" 2" 2" 3/4" 22.5 Gal. LMH-20 18" 35" 2" 2" 2" 3/4" 34 Gal. LMH-40 18" 47" 3" 2" 3" 3/4" 47 Gal. LMH-50 24" 40" 3" 2" 3" 3/4" 69 Gal. LMH-65 24" 44" 3" 2" 3" 3/4" 76 Gal. LMH " 56" 4" 150# Flg 2" 4" 150# Flg 3/4" 98 Gal. LMH " 66" 6" 150# Flg 2" 6" 150# Flg 3/4" 182 Gal. LMH " 123" 6" 150# Flg 2" 6" 150# Flg 3/4" 340 Gal. A Drain Outlet height Liqui-Mover pump specification Furnish and install according to plans and manufacturer s specifications the Kadant Johnson Liqui-Mover pump as shown on the drawings. Operation of the pump is by means of a non-electric float level control having all moving parts stainless steel, open coil actuating springs, reinforced stainless steel float, and condensate inlet baffle. Operating components to include 150 psig ASME labeled steel pump body, inlet and outlet check valves as specified, and snap-acting float level control with no external seals or packing. When specified, a level gauge glass, cycle counter, and insulation jacket are to be furnished. Stainless steel construction and higher pressure ratings also available. 11

12 Packaged Systems The Kadant Johnson packaged Liqui-Mover pump is a non-electric packaged pump that can handle fluid temperatures up to 365 F. There are no rotating seals or packing to leak. Cavitation is impossible. Steam, plant compressed air, or other compatible gases are used to operate the pump. F D G F 3/4" Vent 1/2" Motive C E 3/4" Drain head 3/4" Vent (2) places 1/2" Motive (2) places C Inlet check B Outlet check A 1/2" Drain B Inlet check C 1/2" Motive D F G 1" Vent F 3/4" Drain type E head 1/2" Motive (2) places 1" Vent (2) places Inlet checks (2) C Features u Skid-mounted u Non-electric u No rotating parts u Single trade installation u Custom engineered B F D G A F Outlet check B Benefits u Quick installation u Wear and corrosion resistant u Greater reliability u Reduced operating costs u Operating flexibility E 1" Vent (2) places Inlet check C 1/2" Motive 1" Vent 3/4" Drain type head Outlet check Inlet checks (2) 1/2" Motive (2) places C B A B 12 Model A B C D E F G Receiver Capacity (gal.) LMHT-5XX-LRSM-FSA LMHT-5XX-LRSM-FSA LMV-16XX-LRSM-FSA LMV-16XX-LRSM-FSA LMHT-16XX-LRSM-FSA LMHT-16XX-LRSM-FSA Note: 1. Dimensions are shown in inches. 3. Other multiple pump configurations available. 2. Dimension C based on 24" fill head. 4. Dimensions listed are for reference only.

13 LRSM sizing chart Head Back Pressure LMHT-510 LMV-1610 LMHT-1610 LMV-1615 LMHT-1615 LMV-1620 LMHT-1620 LMV-1630 LMHT-1632 pph pph pph pph pph pph pph pph pph 10 2,100 2,840 3,030 6,370 7,150 9,490 10,770 12,540 13, ,840 2,810 3,010 6,260 7,060 9,270 10,520 12,100 12, ,630 2,770 2,920 6,060 6,880 8,870 10,120 11,470 12, ,470 2,680 2,850 5,670 6,530 8,100 9,410 10,270 11,250 12" 50 1,340 2,530 2,730 5,030 5,940 6,900 8,290 8,550 9, ,220 2,300 2,530 4,180 5,120 5,450 6,840 6,520 7, ,130 2,010 2,270 3,290 4,180 4,060 5,280 4,660 5, ,050 1,680 2,000 2,500 3,270 2,920 3,920 3,250 4, ,370 1,680 1,860 2,480 2,080 2,850 2,250 3, ,080 1,370 1,380 1,860 1,490 2,070 1,580 2,160 Check valve size inlet 1" 1" 1" 1.5" 1.5" 2" 2" 3" 3" Check valve size outlet 1" 1" 1" 1.5" 1.5" 2" 2" 3" 2" Gallons pumped per cycle Note: Above based on steam as the motive pressure. For multiple pumps, multiply above capacity by number of pumps to be used. For Gallons per Minute, divide above capacities by 500. head is the distance between top of the pump tank to the bottom of the receiver/reservoir. Above based on motive pressure being 20 psig higher than total static back pressure. Total static back pressure equals vertical lift plus return line pressure. Capacity conversion factors for other fill heads Head Inlet Check Valve Type LMHT-510 LMV-1610 LMHT-1610 LMV-1615 LMHT-1615 LMV-1620 LMHT-1620 LMV-1630 LMHT " Swing " Swing " Swing " Swing " Non-slam " Non-slam Swing inlet check valve is bronze with teflon disc used up to 24" fill head. Stainless steel inlet check valve is spring loaded NOT for fill head less than 24". Material of construction Part Description LMHT-500 Material LMV-1600 Material LMHT-1600 Material Receiver Tank Pumping Tank Mechanism ASME code stamped 150 psig Shell & heads carbon steel SA-414 G ASME rated 200 psig Tank top & bottom ductile iron SA-395 CL 60 SHCS carbon steel SA-574 Support frame ductile iron SA-395 with nitride surface, valves, springs, & linkage stainless steel ASME code stamped 150 psig Shell & heads carbon steel SA-414 G ASME code stamped 150 psig Shell & bottom head carbon steel SA-414G Flat head top carbon steel SA Mounting flange cast iron SA-278 Support frame ductile iron SA-395 with nitride surface, valves, springs, & linkage stainless steel ASME code stamped 150 psig Shell & heads carbon steel SA-414 G ASME code stamped 150 psig Shell & heads carbon steel SA-414 G Flange ring carbon steel SA-106 C Mounting flange cast iron SA-278 Support frame ductile iron SA-395 with nitride surface, valves, springs, & linkage stainless steel Piping Carbon steel A53 schedule 40 Carbon steel A53 schedule 40 Carbon steel A53 schedule 40 Fittings Malleable iron 150# threaded Malleable iron 150# threaded Malleable iron 150# threaded Isolation Valves Bronze B62 Bronze B62 Bronze B62 Skid Carbon steel AISI 1015 Carbon steel AISI 1015 Carbon steel AISI 1015 Check Valves As specified As specified As specified Gauge Glass Bronze valves with redline glass & brass guard rods Bronze valves with redline glass & brass guard rods Bronze valves with redline glass & brass guard rods Liqui-Mover pump specification Furnish and install according to plans and manufacturer s specifications the Kadant Johnson Liqui-Mover pump package as shown on the drawings. Operation of the pump is by means of a non-electric float level control having all moving parts stainless steel, open coil actuating springs, reinforced stainless steel float, and condensate inlet baffle. Operating components to include 150 psig ASME labeled steel elevated horizontal receiver, 150 psig ASME labeled steel or 200 psig ASME rated ductile iron pump body, inlet and outlet check valves as specified, level gauge glasses, and snap-acting float level control with no external seals or packing. When specified, cycle counter, and insulation jacket are to be furnished. Stainless steel construction and higher pressure ratings also available. 13

14 Application Data To get specific details on a Kadant Johnson Liqui-Mover pump for your application, please complete the requested information and fax the page to or send an to info@kadant.com. Date: Name: Title: Company: Address: City: State: Zip: Phone: Fax: Project Name: Condensate from (type of equipment): Fluid to be pumped: Equipment trapped? Yes No Type of trap: Equipment pressure: Constant psig Modulating Minimum Maximum Maximum condensate load: pph GPM Conductivity: Specific gravity: Steam pressure available: psig Air pressure available: psig Use an existing receiver? Yes No If yes: Diameter: in. Length: in. Capacity: gal. Discharge line pressure: psig Discharge line size: in. Liqui-Mover pump installed: Indoor Outdoor Special requirement: Materials of construction: Stand-by pump: Yes No Insulation: Yes No Cycle counter: Yes No Alarms: High level Low level Existing discharge line Existing return line A. B. C Receiver C. D. A B head D E. (If using an existing receiver) E ( height) Model desired: Existing chamber Pump Pump with receiver 14 Packaged assembly

15 Competitive Upgrade assembly Bolt-in replacement mechanism Stainless steel valves Rugged open coil spring design Heavy linkages and large diameter pivot pins Reinforced stainless steel float Ductile iron support frame with nitride surface 300 series stainless steel spring Features u Stainless steel float mechanism u Designed to retrofit competitive pumps u Exhaustive product testing u Reduced maintenance requirements Benefits u Wear and corrosion resistant u Fast and easy upgrade u Trouble-free, proven technology u Lower total operating costs Operating Conditions PMA (Maximum Allowable Pressure): 150 psig PMO (Maximum Operating Pressure): 90 psid Temperature: 450 F Note: Other pressure and temperature ratings available. Open coil design The Kadant Johnson float assembly has open coil springs in its mechanism. With the open coil design, active coils can not touch. This prevents the active coils from hammering into each other and flattening, which could weaken the springs to the point of breakage. The open coils also prevent deposits from being trapped between the active coils, which could cause etching and breakage of the coils. Reinforced float The weakest area of conventional floats is where the float arm attaches to the ball. The Kadant Johnson float ball has a thicker wall in this area to provide additional support. Spirax, Sarco PPC and PPF ITT Hoffman PCC 1, PCC 1.5, PCC 2, PCC 3 ITT Hoffman PCC 4 and 6 PCS 8 Armstrong PT-300, PT-400, PT-3500 Series MEPCO Dunham Bush Yarway Spence Nicholson Watson McDaniel PMPC SA3V SA3V SA3V SA3V SA3V SA3V SA3V

16 PumpTrap System Do you have temperature or modulated steam control valves on steam coils or heat exchangers? Do you experience any of the following symptoms? u Flooded heat exchangers or steam coils u Frozen steam coils or air handlers u Water hammer in heat exchangers or steam coils u Damaged tube bundles u Poor temperature control in heat exchangers u Poor temperature control in steam coils or air handlers P4 To D.A. tank (5 psig) Lift Condensate header Steam trap P3 Air vent Vacuum breaker Heat exchanger P2 Temp. control valve T2 T1 P1 Steam supply Insufficient differential pressure across a steam trap will not allow condensate to drain properly (see Figure 1). This is commonly known as a stall condition. Figure 1 The Kadant Johnson solution is to install a PumpTrap (see Figure 2). A PumpTrap should be installed on a single steam coil or heat exchanger, never multiple steam users. A properly sized steam trap has been installed at the outlet of the Liqui-Mover pump. The steam trap operates normally when there is enough system pressure to overcome the back pressure. When the system pressure becomes equal to or less than the back pressure, the Liqui-Mover pump will pump the condensate through the steam trap and into the overhead return line. Steam should always be used as the motive pressure. P4 To D.A. tank (5 psig) P3 Condensate header Air vent Equalize line Steam trap Liqui-Mover Reservoir Air vent Vacuum breaker Heat exchanger P2 Temp. control valve T2 T1 Motive steam P1 Steam supply Example (see Figure 1): P1 Steam supply pressure to control valve 50 psig P2 Design pressure to heat exchanger 30 psig P3 Static back pressure (P4 + Lift) 11.5 psig P4 Return line pressure 5 psig Vertical lift 15 feet = 6.5 psig Figure 2 Minimum condensate stall pressure 11.5 psig Equalization line operated pump level control Motive steam line 150 psig ASME coded steel tank Condensate inlet External glass gauge and thermostatic steam trap Inlet check valves 16 Outlet check valves Condensate discharge

17 Application Data PumpTrap To get specific details on a Kadant Johnson Liqui-Mover PumpTrap for your application, please complete the requested information and fax the page to or send an to info@kadant.com. Date: Name: Title: Company: Address: City: State: Zip: Phone: Fax: Project Name: Condensate from (type of equipment): Maximum condensate load: pph GPM Specific gravity: Steam pressure available: psig Liqui-Mover pump installed: Indoor Outdoor Special requirement: Materials of construction: Stand-by pump: Yes No Cycle counter: Yes No Insulation: Yes No Alarms: High level Low level P3 Pumped return line Temp. control valve P2 P1 Air vent Vacuum breaker Steam supply P1 PSIG D2 Steam user Temp. out - T2 Temp. in - T1 P2 TO PSIG P3 PSIG T1 F Condensate return unit D1 T2 D1 F IN.. D2 IN 17

18 Energy Loss Vented or flash steam contains valuable heat energy. If the flash steam can be captured, utilized, and returned to the boiler, your total steam generation costs may be reduced. This includes a reduction in make-up water, treatment chemicals, and possibly sewer costs. Operating conditions: A. Condensate pressure: 50 psig flashing to 0 psig B. Condensate load: 10,000 lb/hr C. Cost of steam: $5.00 per 1,000 lb D. Specific volume of water: gal/lb (40 F to 60 F) E. Make-up water and chemical cost: $5.00 per 1,000 gallons F. Hours of operation (annually): 6,000 hours Calculations Estimated Steam Loss: 1. Flash loss = 9% See chart below. 2. Lb/hr loss = B x flash loss 10,000 x 9% = 900 lb/hr 3. Lb/year loss = F x 900 lb/hr 6,000 x 900 = 5,400,000 lb/year 4. $ loss/year = lb/year x C 5,450,000 x $5.00 = $27,000 loss/year 1,000 Estimated water loss: 5. Gal/year of make-up water = lb/year loss x D 5,400,000 x = 648,000 gal/year 6. $ water loss/year = gal/year x E 648,000 x $5.00 = $3,240 loss/year 1,000 Total estimated dollar loss (Step 4 + Step 6): $27,000 + $3,240 = $30,240 Percentage flash generated Inlet Condensate psig Flash Tank psig

19 Sizing Flash tank and vent line sizing The tables below will assist you in choosing the correct size receiver tank and vent line size for your application. Simply calculate the amount of flash steam that will be generated and use this number to find the correct receiver and vent line. Vent line capacity at 0 psig (Based on 50 FPS or 3000 FPM velocity) Pipe Size 1" 1-1/2" 2" 3" 4" 6" 8" 10" 12" 14" 16" Capacity (lb/hr) ,348 2,334 3,678 5,221 6,310 8,243 Flash tank capacity at 0 psig Flash Tank Size LMH-5 10 x Gal. LMH x Gal. LMH x Gal. LMH x Gal. LMH x Gal. LMH x Gal. LMH x Gal. LMH x Gal. LMH x Gal. Lb/hr Flash Steam ,041 Pipe accumulators as receivers/reservoirs Approximate pipe lengths (in feet) needed for equivalent receiver capacity Pipe Size (Sch 40) Gallons per Foot LMH-5 10 x Gal. LMH x Gal. LMH x Gal. LMH x Gal. LMH x Gal. LMH x Gal. LMH x Gal. LMH x Gal. LMH x Gal. 3" " " " " " " " " " "

20 Local Assistance On A Worldwide Basis Many suppliers have made a commitment to the international marketplace. But few have taken that commitment as far as Kadant Johnson. To assure product availability wherever it's needed, Kadant Johnson joints, syphons, and related equipment are manufactured in Asia, Europe, North America, and South America. Because knowledgeable advice and prompt service are as important as the products, Kadant Johnson has factoryauthorized representatives in nearly 150 countries. So no matter where you are, Kadant Johnson products, service, and assistance are nearby. MANUFACTURING LOCATIONS 805 Wood Street Three Rivers, MI USA tel: fax: Nijverheidslaan AB Weesp, The Netherlands tel: fax: Rua Miguel Nelson Bechara, , São Paulo, SP, Brazil tel: fax: Kadant is a leading global supplier of products and services that improve productivity and quality in paper production and other process industries. For the nearest location and contact, visit our Website. Contact us: Wuxi National Hi-Tech Industrial Development Zone Wuxi City, Jiangsu Province, China tel: fax: KADANT JOHNSON INC. 805 Wood Street Three Rivers, MI USA Tel: Fax: info@kadant.com Operated Pumps /2009 replaces: Operated Pumps Kadant Inc.

SX Rotary Joints For steam or thermal oil service

SX Rotary Joints For steam or thermal oil service SX Rotary oints or steam or thermal oil service Self-aligning seal with dual carbon bearing support. Engineered reliability and performance. Table of ontents SX Rotary oint verview..................................................................3

More information

Type SX Rotary Joints

Type SX Rotary Joints Type SX Rotary oints or steam or thermal oil service Self-aligning seal with dual carbon bearing support. Engineered reliability and performance. Table of ontents SX Rotary oint verview..................................................................3

More information

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B Technical Data SD 9952B SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NEW YORK, 12586-2035 P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP Pressures To 250 PSIG (20.7 barg) Temperatures

More information

PT-516 Pumping Trap Installation and Maintenance

PT-516 Pumping Trap Installation and Maintenance PT-516 Pumping Trap Installation and Maintenance IB-104-B This bulletin should be used by experienced personnel as a guide to the installation and maintenance of the PT-516 Pumping Trap or Pumping Trap

More information

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure

More information

SECTION H3 TRAYMASTER SERIES DEAERATORS

SECTION H3 TRAYMASTER SERIES DEAERATORS SECTION H3 TRAYMASTER SERIES DEAERATORS SAMPLE SPECIFICATIONS PART 1 GENERAL... H3-12 1.1 Packaged Deaerator Specification... H3-12 PART 2 PRODUCTS... H3-12 2.1 Deaerator... H3-12 2.2 Deaerator Vessel...

More information

W4100, W4200 & W4300 Electric Pump

W4100, W4200 & W4300 Electric Pump Electric Condensate Pumps W4100, W4200 & W4300 Model W4100 W4200 W4300 Connections NPT NPT NPT Tank Material Carbon Steel Cast Iron Stainless Steel Max Disch. Press. 50 PSIG 50 PSIG 50 PSIG TMO/TMA 190

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

The Pivotrol Pump Patented Selection and Sizing

The Pivotrol Pump Patented Selection and Sizing How to Select and Size From the inlet pressure, back pressure and filling head conditions given below, select the pump size and check valve package which meets the capacity requirement of the application.

More information

Pressure Relief Valves. 1541/1543 Series. Consolidated Safety Valve

Pressure Relief Valves. 1541/1543 Series. Consolidated Safety Valve Pressure Relief Valves 1541/1543 Series Consolidated Safety Valve Table of Contents Conversion Table 1541/1543.2 Features & Benefits 1541/1543.3 Applications 1541/1543.3 Scope of Design 1541/1543.4 Materials

More information

* T Temperature-Indicating Dial (Must be field set and calibrated to an actual thermometer)

* T Temperature-Indicating Dial (Must be field set and calibrated to an actual thermometer) 175/153 Series Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2006 Watson McDaniel Company 175 HEATING 153 COOLING 175 / 153 Screwed Connection

More information

SAMPLE SPECIFICATIONS

SAMPLE SPECIFICATIONS SAMPLE SPECIFICATIONS CONTENTS PART 1 GENERAL...H1a-12 1.1 DEAERATOR SPECIFICATION...H1a-12 PART 2 PRODUCTS...H1a-12 2.1 HARDWARE...H1a-12 A. Deaerator...H1a-12 B. Make Up Valve and Controller...H1a-14

More information

SECTION H4 BOILERMATE DEAERATORS

SECTION H4 BOILERMATE DEAERATORS SAMPLE SPECIFICATIONS PART 1 SECTION H4 BOILERMATE DEAERATORS GENERAL...H4-14 1.01 General...H4-14 PART 2 PRODUCTS...H4-14 2.01 Hardware...H4-14 A. Deaerator...H4-14 B. Make Up Valve and Controller...H4-15

More information

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance 119 Overview Warning: This bulletin should be used by experienced personnel as a guide to the installation and maintenance

More information

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer Design & Operation W91 Non-Indicating W94 Dial Thermometer Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company CAPILLARY

More information

15100 VALVES. E. Section Building Automation and Control System Guidelines

15100 VALVES. E. Section Building Automation and Control System Guidelines 15100 VALVES PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 15050 Basic Material and Methods B. Section 15545 Chilled Water System C. Section 15550 Heat Generation D. Section 15790 Coils E. Section 15955

More information

SECTION Pressure & Temperature Control

SECTION Pressure & Temperature Control 16 Pressure & Temperature Control ARMSTRONG PRODUCT CATALOGUE 70 Pressure Reducing s Pressure Reducing s Armstrong pressure reducing valves (PRVs) and temperature regulators help you manage steam, air

More information

TEMPERATURE REGULATORS W91/W94 Series

TEMPERATURE REGULATORS W91/W94 Series Self-Operated Temperature Regulators Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company Self-Operating Design Indicating

More information

A. Provide all HVAC specialties required to complete the installation of all HVAC systems. B. Manufacturers: Refer to individual product item.

A. Provide all HVAC specialties required to complete the installation of all HVAC systems. B. Manufacturers: Refer to individual product item. DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 05 02 PART 1 GENERAL 1.01 DESCRIPTION A. Provide all HVAC specialties required to complete the installation of all HVAC systems.

More information

TYPE PC Propeller Condensate Pumps

TYPE PC Propeller Condensate Pumps SHIPPENSBURG PUMP CO. INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PH 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 103 Revised 8/17 TYPE PC Propeller Condensate Pumps with Cast Iron Receivers

More information

4" PPF-P Pilot-Operated Pressure Powered Pump

4 PPF-P Pilot-Operated Pressure Powered Pump INSTALLATION AND MAINTENANCE INSTRUCTIONS IMI 5.220 January 1996 4" PPF-P Pilot-Operated Pressure Powered Pump Operating Pressure Range 25 to 150 psi (1.7 to 10.3 bar) The 4" PPF-P incorporates a spring-loaded,

More information

MFP14 Automatic Pumps Installation and Maintenance Instructions

MFP14 Automatic Pumps Installation and Maintenance Instructions 1360850/6 IM-P136-03 ST Issue 6 MFP14 Automatic Pumps Installation and Maintenance Instructions 1 2 3 4 5 6 7 8 General Operation Installation Commissioning Maintenance Fault finding Spare parts Typical

More information

1541/1543 Series. Consolidated * Valves. Safety Valve

1541/1543 Series. Consolidated * Valves. Safety Valve GE Oil & Gas Technical Specifications 11/2014 Consolidated * Valves 1541/1543 Series Safety Valve Designed for steam and other compressible fluids, these valves are most commonly used in pharmaceutical,

More information

CUSTOM COMBINATION AIR VALVE

CUSTOM COMBINATION AIR VALVE INSTALLATION / OPERATION / MAINTENANCE CUSTOM COMBINATION AIR VALVE INTRODUCTION This manual will provide you with the information to properly install and maintain this valve to ensure a long service life.

More information

Minuteman Vertical Pumps

Minuteman Vertical Pumps Description: Condensate Pumps Type: Vertical Centrifugal Pumps Horsepower: /3 to /2 HP GPM: 0 to 37 PSIG: 0-35 Overview: vertical pumps are the workhorse of the NES pumps product offering. All minuteman

More information

COMMERCIAL. Product PRofile

COMMERCIAL. Product PRofile Product PRofile 2 PRODUCT OVERVIEW INtroduction At Bray International, Inc., our business is helping our customers with their flow control requirements. Our modular product line of butterfly, ball and

More information

G Rotary Unions. For coolant, water, oil and air service. High speed rotating unions for transferring fluids and air.

G Rotary Unions. For coolant, water, oil and air service. High speed rotating unions for transferring fluids and air. G Rotary Unions or coolant, water, oil and air service Precision rotary unions for more effective cooling and lubrication. High speed rotating unions for transferring fluids and air. ontents Type G Rotary

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15100 VALVES PART 1 DESIGN DIRECTIVE 1.1 SUMMARY A. This Section includes general duty valves common to most mechanical piping systems, special duty valves are specified in individual piping system

More information

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No. SECTION 23 22 13 STEAM AND CONDENSATE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

The Universal Sewer Air Release Valve is designed to permit

The Universal Sewer Air Release Valve is designed to permit Universal Sewer Valves Universal Sewer Valves Valve Function Exhausts air as a pipeline fills, and allows air in as pipeline drains Allows accumulating air to escape while line is in operation Features

More information

D-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features

D-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features D26.SWG.CAT.ENG0 D-26 Wastewater Combination Air Valve for Wastewater Description The D-26 Combination Air Valve combines an air & vacuum component and an air release component in a single body. The valve

More information

Fabricated Duplex Strainers

Fabricated Duplex Strainers Applications Chemical Industry Metals & Mining Process Industry Water & Waste Water Power Industry Pulp & Paper Oil & Gas Fabricated Duplex Strainers Pressures to 1480 PSIG Temperatures to 800ºF FEATURES

More information

Installation and Maintenance Manual Duplex Pressure Powered Pump Package Unit with Insulation Jacket and Condensate Recovery Meter PPPPU-D

Installation and Maintenance Manual Duplex Pressure Powered Pump Package Unit with Insulation Jacket and Condensate Recovery Meter PPPPU-D Installation and Maintenance Manual Duplex Pressure Powered Pump Package Unit with Insulation Jacket and Condensate Recovery Meter PPPPU-D Energy Conservation Environment Process Efficiency www.forbesmarshall.com

More information

Pressure Relief Valves Series. Consolidated Safety Valve

Pressure Relief Valves Series. Consolidated Safety Valve Pressure Relief Valves 1511 Series Consolidated Safety Valve Consolidated Type 1511 safety valves are designed for low pressure, steam heating boilers and steam generators as well as air service applications.

More information

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features PN 16 / 25 Wastewater Combination Air Valve for Wastewater PATENTED EuroC-D023SWG-15-2 Description The D-023 Combination Air Valve combines an air & vacuum component and an air release component in a single

More information

Hoffman Specialty General Catalog

Hoffman Specialty General Catalog Hoffman Specialty General Catalog HS-900G ESP-PLUSTM For computer aided selection of Steam Trap and Regulators, please refer to the Steam Specialty Component Selectors at http://bellgossett.com/selectionsizing-cad-tools/

More information

Suction Diffusers. Applications PROTECTION PUMP. Pressures to 790 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZE RANGES RATINGS

Suction Diffusers. Applications PROTECTION PUMP. Pressures to 790 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZE RANGES RATINGS Applications Process Industry Metals and Mining Power Industry Water and Waste Chemical Industry Pulp and Paper Oil and Gas Suction Diffusers Pressures to 790 PSIG Temperatures to 800ºF FEATURES Filtration

More information

Series Low Pressure Steam Heating Boiler Safety Valves

Series Low Pressure Steam Heating Boiler Safety Valves 12-200 Series Low Pressure Steam Heating Boiler Safety Valves Section IV Heating Boilers Medium capacity safety valves protect ASME Section IV low pressure steam heating boilers. Cast bronze, full nozzle

More information

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications. 7 YARWAY Hancock T-Pattern Globe valves Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications Features Heavy integral stellite hardfacing on

More information

Basket Strainers. Applications. Pressures to 3705 PSIG. Temperatures to 800ºF FEATURES MATERIALS OF CONSTRUCTION END CONNECTIONS SIZES RATINGS

Basket Strainers. Applications. Pressures to 3705 PSIG. Temperatures to 800ºF FEATURES MATERIALS OF CONSTRUCTION END CONNECTIONS SIZES RATINGS Applications Process Industry Metals and Mining Power Industry Water & Waste Water Chemical Industry Pulp and Paper Oil and Gas Basket Strainers Pressures to 3705 PSIG FEATURES Temperatures to 800ºF Fabricated

More information

Regenerative Turbine Pumps

Regenerative Turbine Pumps Bulletin E4 November 009 E4 T4 Series Regenerative Turbine Pumps Capacities to GPM Heads to 600 Feet Temperatures to 00 F MTH PUMPS MTH E4 T4 Series Close-coupled and pedestal mounted regenerative turbine

More information

US SERIES. Universal Sewer Valves. Universal Sewer Valves. Valve Function. Features Include

US SERIES. Universal Sewer Valves. Universal Sewer Valves. Valve Function. Features Include Valve Function Exhausts air as a pipeline fills, and allows air in as pipeline drains Allows accumulating air to escape while line is in operation Features Include Standard and short body series available

More information

The PL Series Pressure Air Release Valves. Sizes 1 thru 6 Available Compound Lever System Adjustable Buna-N Rubber Plunger. Crispin.

The PL Series Pressure Air Release Valves. Sizes 1 thru 6 Available Compound Lever System Adjustable Buna-N Rubber Plunger. Crispin. The PL Series Sizes 1 thru 6 Available Compound Lever System Adjustable Buna-N Rubber Plunger Crispin Since 1905 PL SERIES Functio n Allows air and/or gas to be released from a pressurized liquid system

More information

VIFB Coil Technical Guide

VIFB Coil Technical Guide TGVIFB-5 VIFB Coil Technical Guide VERTICAL TUBE INTEGRAL FACE AND BY-PASS HEATING COILS FOR AIR PREHEATING Since 1875, the L.J. Wing Company has been a leader in providing innovative solutions for difficult

More information

390 Series Multi-Stage Vertical In-Line Centrifugal Pumps

390 Series Multi-Stage Vertical In-Line Centrifugal Pumps Bulletin 390 /Rev. B 390 Series Multi-Stage Vertical In-Line Centrifugal Pumps Capacities to 400 G.P.M. (91 M 3 /HR) Heads to 800 Feet (243 Meters) Temperatures to 250 F (120 C) motralec 4 rue Lavoisier.

More information

The TD Series Tilting Disc Check Valve Sizes from 2 to 72 #125 and #250 ratings available 55 seating angle 40% size increase through seat.

The TD Series Tilting Disc Check Valve Sizes from 2 to 72 #125 and #250 ratings available 55 seating angle 40% size increase through seat. The Series Sizes from 2 to 72 #125 and #250 ratings available 55 seating angle 40% size increase through seat Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603

More information

Biogas safety control equipment

Biogas safety control equipment Biogas safety control equipment As environmental concerns and energy efficiency are increasing, efficient economical and safe gas control systems become an increasingly important part of operating the

More information

APT14 Automatic Pump Trap Installation and Maintenance Instructions

APT14 Automatic Pump Trap Installation and Maintenance Instructions 6120250/7 IM-P612-04 ST Issue 7 APT14 Automatic Pump Trap Installation and Maintenance Instructions 1 Product information 2 Operation 3 Installation Closed loop steam systems only 4 Commissioning 5 Maintenance

More information

Recold JW Series. Lenntech. Tel Fax ENGINEERING DATA AND SPECIFICATIONS

Recold JW Series. Lenntech. Tel Fax ENGINEERING DATA AND SPECIFICATIONS Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 ENGINEERING DATA AND SPECIFICATIONS Recold JW Series FLUI D COOLER Recold JW Series Fluid Cooler Contents 2 Construction...

More information

ISO 9001 : Dual Plate Wafer Check Valves. API 594 Design API 598 Tested. Maximizing the Flow

ISO 9001 : Dual Plate Wafer Check Valves. API 594 Design API 598 Tested. Maximizing the Flow ISO 9001 : 2008 Dual Plate Wafer Check Valves API 594 Design API 598 Tested Maximizing the Flow Meets API/ANSI/ASME Specifications Quick Delivery Dual Plate Wafer Check Valves The Industry Standard Dual

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES SECTION 23 05 23 HVAC&R VALVES PART 1 - GENERAL 1.1 SUMMARY: A. Section includes valves for building services piping. 1.2 GENERAL VALVE APPLICATION REQUIREMENTS: A. Provide valve handle extensions that

More information

Series Direct contact, metal-to-metal seating, make the globe valve ideal for most shut-off applications. Features

Series Direct contact, metal-to-metal seating, make the globe valve ideal for most shut-off applications. Features Direct contact, metal-to-metal seating, make the globe valve ideal for most shut-off applications. Features General application Designed for ASME boiler and pressure vessel code, section I applications

More information

IMMERSION FIRED HOT WATER BOILER

IMMERSION FIRED HOT WATER BOILER 918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8301 IMMERSION FIRED HOT WATER BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series

More information

Gauges, Sight Glasses and Vacuum Breakers

Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges Pressure gauges Pressure gauges should be installed in at least the following situations: Upstream of a pressure

More information

Series CC Condensate Units

Series CC Condensate Units Bulletin S-215F Series CC Condensate Units Simplex or Duplex 1,000 thru 15,000 sq. ft. EDR 250 thru 7,500 lb./hr. Cast Iron Receivers: for years of dependable service; warranted for 20 years from date

More information

SECTION METERS AND GAGES FOR HVAC PIPING

SECTION METERS AND GAGES FOR HVAC PIPING PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. 1.2 SUMMARY A. This

More information

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating 1/4" NPT VENT 'A' 1/4" NPT 2 - REQ'D 'D' REQ D FOR BASKET REMOVAL 'B' FLOW 'C'

More information

VB-9323 Series. Application. Features. Applicable Literature. 2-1/2" to 6" 125 Lb. Flanged Three-Way Diverting Valves General Instructions

VB-9323 Series. Application. Features. Applicable Literature. 2-1/2 to 6 125 Lb. Flanged Three-Way Diverting Valves General Instructions TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com VB-9323 Series 2-1/2" to 6" 125 Lb. Flanged Three-Way Diverting Valves General Instructions Application VB-9323 series three-way

More information

T205VB Series Tank Blanketing Vacuum Breakers

T205VB Series Tank Blanketing Vacuum Breakers February 2014 T205VB Series Tank Blanketing Vacuum Breakers Figure 1. Typical T205VB Series Vacuum Breaker Introduction The T205VB Series vacuum breakers (Figure 1) are used for precise control of small

More information

SNX and SX Rotary Joints

SNX and SX Rotary Joints SNX and SX Rotary Joints For steam and thermal oil service Self-aligning seal with dual carbon bearing support. Engineered reliability and performance. Table of Contents SNX Rotary Joint Overview..................................................................3

More information

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features D00.WTR.CAT.ENG0 D-00 PN 1 Water Supply D-00-C PN 1 Combination Air Valve Description The D-00 series Combination Air Valve has the features of both an air release valve and an air & vacuum valve. The

More information

Commercial Sewage & Waste Water Systems

Commercial Sewage & Waste Water Systems Commercial Sewage & Waste Water Systems EDP-4 72 Gallon 24 x 36 Basin EDP-6 108 Gallon 30 x 36 Basin EDP-8 158 Gallon 36 x 36 Basin 1/2 HP pump 2 PVC Sch 80 discharge, 3 float switches and cover 2 NPT,

More information

Product Instructions. Mixing Station. Features. Specifications. Materials

Product Instructions. Mixing Station. Features. Specifications. Materials Mixing Station The Viega Mixing Station provides supply water temperature modulation when connected to a variety of heat sources such as conventional or condensing boilers, water heaters, or geothermal

More information

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support Bulletin C 1.4.43 Dean Pump Division Heavy Duty, High Temperature Process Pumps R4140 Telescoping Guard R4140 C-Face Motor Support Dean Pump Series R Centrifugal Process Pumps Capacities to 5000 GPM (1135

More information

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST Date Documents Submitted: Log No.: File No.: Plan Examiner: Permit No.: Property Information Building Name: Building Address: Building Manager's Name: Building Manager's Phone: Fax: System Designer/Contractor

More information

HD Series. Pilot-Operated Regulating Valves. HD Series features & benefits

HD Series. Pilot-Operated Regulating Valves. HD Series features & benefits Watson McDaniel reserves the right to change the designs and/or materials of its products out notice. 2004 Watson McDaniel Company features & benefits Ductile Iron body for higher pressures Full port strainer

More information

13900 Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

13900 Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve GE Oil & Gas Technical Specifications 08/2014 Consolidated * Valves 13900 Series Pilot-Operated Safety Relief Valve Designed specifically for high capacity steam applications, this series of valves contributes

More information

Series Low Pressure Steam Boiler Safety Valves

Series Low Pressure Steam Boiler Safety Valves 14-200 Series Low Pressure Steam Boiler Safety Valves ASME Section IV Set pressures from 5 to 15. Sizes 2", 2-1/2" and 3". Section IV Heating Boilers Applications: The 14 Series is an ASME Section IV high

More information

The SC Series Surge Check Valves Sizes 3 thru 24 Available Cast Iron Construction Limits the Effects of System Surge on Air Release Valves.

The SC Series Surge Check Valves Sizes 3 thru 24 Available Cast Iron Construction Limits the Effects of System Surge on Air Release Valves. The Series Sizes 3 thru 24 Available Cast Iron Construction Limits the Effects of System Surge on Air Release Valves Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA

More information

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS Model Models 4 & AURORA 0 SERIES SINGLE STAGE TURBINE TYPE PUMPS WWW.AURORAPUMP.COM AURORA 0 SERIES Single Stage Turbine Type Pumps Capacities to 0 G.P.M. Heads to 700 Ft. Temperatures to F A Pioneer in

More information

APT10-2 Automatic Pump Trap

APT10-2 Automatic Pump Trap 6120050/3 IM-P612-18 ST Issue 3 APT10-2 Automatic Pump Trap Installation and Maintenance Instructions 1. General safety information 2. Product information 3. Installation Closed loop steam systems only

More information

Consolidated* Valves 1511 Series Safety Valve

Consolidated* Valves 1511 Series Safety Valve Technical Specifications Rev. B - 10/2018 Consolidated* Valves 1511 Series Safety Valve Offering proven, high-performance design for low-pressure, steam heating boilers and steam generators, as well as

More information

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1 Packaged Pump Sets for Diesel/Fuel Oil Application Page 1 Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION Packaged Pump Sets for Diesel/Fuel Oil Application Page 2 Description Simplex SPS Series Packaged

More information

GTD-Series. Direct Gas Actuators

GTD-Series. Direct Gas Actuators GTD-Series Direct Gas Actuators GTD-Series Direct Gas Actuators Enclosed Cast Housing Bearings Xylan Coated Internals Piston Seals Travel Stop Vent Check NAMUR Acculine Shaft Drive Features and Benefits

More information

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 377 Float Cage / 326L & 322L lever Valves TABLE OF CONTENTS Overview... Cover General Information... Cover Operation... 4 Installation...4-6 Maintenance...

More information

Model 3550 ASME/ANSI B73.1M Industrial Process Pumps

Model 3550 ASME/ANSI B73.1M Industrial Process Pumps 3500 Series Model 3550 ASME/ANSI B73.1M Industrial Process Pumps The Aurora Model 3550 was designed to perform in the toughest industrial applications whether in the chemical, petro-chemical, mining, pulp

More information

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions Installation, Operation & Maintenance Instructions 377 Float Cage / 326L & 322L lever Valves TABLE OF CONTENTS Overview... Cover General Information... Cover Operation... 4 Installation...4-6 Maintenance...

More information

SECTION METERS AND GAGES FOR PLUMBING PIPING

SECTION METERS AND GAGES FOR PLUMBING PIPING PART 1 GENERAL 1.01 SECTION INCLUDES A. Positive displacement meters. B. Flow meters. SECTION 22 0519 METERS AND GAGES FOR C. Pressure gages and pressure gage taps. D. Thermometers and thermometer wells.

More information

series2500 TEXSTEAM Pumps ELECTRIC DRIVEN INJECTION PUMP PRODUCT FEATURES MODEL DESIGNATION

series2500 TEXSTEAM Pumps ELECTRIC DRIVEN INJECTION PUMP PRODUCT FEATURES MODEL DESIGNATION TEXSTEAM Pumps series2500 ELECTRIC DRIVEN INJECTION PUMP PRODUCT FEATURES Maximum discharge pressure: 6,000 PSI (1 bar) w/ 3/16 plunger Maximum volume gallons per day (52 liters per day) w/ 1/2 plunger

More information

Direct contact, metal-to-metal seating, make the gate valve ideal for most shutoff applications. Class 800 ANSI.

Direct contact, metal-to-metal seating, make the gate valve ideal for most shutoff applications. Class 800 ANSI. Direct contact, metal-to-metal seating, make the gate valve ideal for most shutoff applications. Class 800 ANSI. Features Two inch and smaller valves are available with threaded or socket weld ends as

More information

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems. SECTION 220523 - PLUMBING VALVES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Ball valves. 2. Butterfly valves. 3. Swing check valves. 4. Spring loaded check valves. 5. Water pressure reducing

More information

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance Features & Benefits Table of Contents Features & Benefits................................................................ 13900.1 Scope of Design...................................................................

More information

LIQUI-MOVER PUMP HANDBOOK

LIQUI-MOVER PUMP HANDBOOK LIQUI-MOVER PUMP HANDBOOK Kadant Johnson Inc., 805 Wood Street, Three Rivers, MI 49093 USA 269-278-1715 fax: 269-279-5980 www.kadant.com LMP Handbook-4002 What is a Liqui-Mover Pump? A Liqui-Mover pump

More information

High Temperature Chemical Process Inline Pumps

High Temperature Chemical Process Inline Pumps Bulletin C-1.2.21. Dean Pump Division High Temperature Chemical Process Inline Pumps Series DL Series DL High Temperature Chemical Process Inline Pumps Capacities to 6 GPM (182 m 3 /hr) Heads to feet (167

More information

JAMESBURY EASYFLOW JT SERIES ANGLE STEM TANK BOTTOM VALVES

JAMESBURY EASYFLOW JT SERIES ANGLE STEM TANK BOTTOM VALVES JAMESBURY EASYFLOW JT SERIES ANGLE STEM TANK BOTTOM VALVES JT series angle stem tank bottom valves provide a compact assembly with additional space for actuator clearance on insulated vessels. Large port

More information

GTD-Series. Direct Gas Actuators

GTD-Series. Direct Gas Actuators GTD-Series Direct Gas Actuators GTD-Series Direct Gas Actuators Enclosed Cast Housing Yoke Pin B Travel Stop Vent Check NAMUR Acculine Shaft Drive Features and Benefits For more than 50 years Bettis and

More information

Includes electric operated valve Pressure gauge with siphon, vacuum breaker and air vent BOILER UNITS

Includes electric operated valve Pressure gauge with siphon, vacuum breaker and air vent BOILER UNITS STEAM / HOT WATER MODELS HWG FEATURES A. O. Smith hot water generators are available for operation with steam or boiler water as the energy source. They are completely assembled with components sized,

More information

Regenerative Turbine Pumps

Regenerative Turbine Pumps Bulletin E4 July E4/T4 Series Regenerative Turbine Pumps Capacities to GPM Heads to 6 Feet Temperatures to F MTH E4/T4 Series Close-coupled and pedestal mounted regenerative turbine pumps represent the

More information

Portable. Storage and Transport Dewars. CL/CLPB Series, CH Series, CFN/CFL Series

Portable. Storage and Transport Dewars. CL/CLPB Series, CH Series, CFN/CFL Series Portable Storage and Transport Dewars CL/CLPB Series, CH Series, CFN/CFL Series CL/CLPB Series Cryofab s CL series portable liquid cylinders are intended for low-pressure transport and storage of liquid

More information

YARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000

YARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000 Direct contact and metal-to-metal seating make this Y-pattern globe stop valve ideal for most shut-off applications. FEATURES All valves feature integral Stellite hardfacing on both body and disc seating

More information

PIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5

PIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5 PERFORMANCE SPECIFICATIONS PIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5 PIC-V Valve 1. PRESSURE INDEPENDENT ACTUATED BALL VALVES AND CARTRIDGE (PIC-V)

More information

Electronic Ball Valve Guide Specifications

Electronic Ball Valve Guide Specifications Electronic Ball Valve Guide Specifications Control Valve Assemblies Ball Valve Bodies All ball valves used for modulating or floating (tri-state) control must be furnished with a stainless steel ball &

More information

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC Installation, Operation & Service Manual PPL Bag Filter Housings Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Read all instructions before installation or operation of equipment. Failure

More information

VALVES. A. Section HVAC Basic Materials and Methods. E. Section Building Automation and Control System Guidelines

VALVES. A. Section HVAC Basic Materials and Methods. E. Section Building Automation and Control System Guidelines 230523 VALVES PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230500 HVAC Basic Materials and Methods B. Section 230510 Chilled Water System C. Section 230520 Heat Generation D. Section 238216 Coils E.

More information

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features D-00 PN 1 Water Supply D-00-C PN 1 Combination Air Valve EnC-D00WTR-11 Description The D-00 series Combination Air Valve has the features of both an air release valve and an air & vacuum valve. The air

More information

SRX R. Remediation Pumps. Simply Reliable

SRX R. Remediation Pumps. Simply Reliable SRX R Remediation Pumps Simply Reliable The SRX pump is based on a simple, innovative design and built with fi eld-proven components. The result: a reliable pump to meet the demands of your remediation

More information

CASH VALVE SERIES FR BACK PRESSURE VALVES

CASH VALVE SERIES FR BACK PRESSURE VALVES Diaphragm actuated valves designed for either continuous or intermittent operation which provide accurate, repetitive pressure control FEATURES GENERAL APPLICATION For use on practically all fluids and

More information

Python Series Control Valves

Python Series Control Valves s When accurate control is desired from your steam or water applications the Armstrong Python 1100 Series Control Valve will squeeze every bit of performance out of your system and deliver precise control.

More information

CONTROL VALVES QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Innovative Solutions

CONTROL VALVES QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Innovative Solutions CONTROL VALVES REPUTATION BUILT ON QUALITY, DEPENDABILITY, SERVICE. www.cashco www.valtron.co.za com Get Consistent Quality By involving every employee in our ISO 9001:2000 Quality Assurance Program, you

More information

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS The DuraMAC TM Water Pressure Booster System is the first booster pump of its kind to be designed for virtually

More information