Liquid level sensors. r: Features. Description

Size: px
Start display at page:

Download "Liquid level sensors. r: Features. Description"

Transcription

1 0904 Liquid level sensors r: Features -- Accurate liquid level sensing Solid-state (LL) or Reed-switch (LRN) technology High degree of sealing Compact and reliable Quick response time Suitable for use in a wide range of liquids Various housings and mounting versions Custom packaging available Easy to install Cost effective Description The Honeywell range 01 liquid level sensors offers the design engineer a combination 01 versatility and reliability. They can be used in most chemical and temperature environments. The LL series are TTL compatible, while the LRN series offers higher current switching capability.

2 LRN Series Reed float switch Features High or low level sensing Normally open, normally closed or change over contact action Ratings up to 100W Operates in liquid down to S.G Internal or external litting Easy to install Cost effective Description The Honeywell range 01 horizontal, vertical and right angled Iloat switches offers the design engineer a combination 01 versatility and reed switch reliability. A magnet located in the Iloat is used to activate the reed switch either on a rising or lalling liquid level and the design allows lor high or low level sensing simply by rotating the switch through 180 C. A range 01 internal or external mounting options is available and a universal mounting kit allows both internal and external mounting. Available in Nylon 6.6 and Glass Filled Polypropylene materials and a range 01 switching options. LRN Iloat switch es are suitable lor use in the automotive, chemical, petroleum and lood processing industries in signalling and control applications. Technical Mechanical information Minimum operate angle 5 Irom mounting angle Maximum release angle 40 Irom mounting angle Shock' 50g lor 11 milliseconds duration Vibration' Nominal cable length 0.5 m Environmental 35 up to 500Hz Nylon 6.6 Diecast metal" Glasslilled body polypropylene Operating Temperature Range -30 C to -30 C to -30 C to +130 C +130 C +110 C Minimum SG 01 liquid Minimum Viscosity 01 Liquid (centipoise) Plastic Housing Water absorption 01 equilibrium at 20 C and 100 % RH 1.3% 5.6 % 0.03% at 100 C and 100 % RH 1.6% 5.6% <0.5 % Heat distortion temperature 180 C 245'C 105 C 4.5 kglcm' (67.6 psig) Electrical Switching options O Switch action SPST SPST SPDT SPST TRIAC TRIAC Maximum Switching Voltage (VDC) (VRMS) Maximum Switching Current (A) DC Contact Rating (W) Minimum Breakdown Voltage (VDC) Initial Contact Resistance (O) Reed SWitch Only Diecast metal model is litted with Nylon 6.6 Iloat as standard The switching performance can be drastically affected il switch ratings are exceeded. For inductive, capacitive and tungsten filament lamp loads, derate by 50%. AII switch ratings are at DC resistive loads. Emergency cut out Typical Applications Low coolant level sensing Fuel or oil level sensing Boiler level warning Solution monitoring Flood control Catering and vending machine Domestic appliance Medical equipment High level Low level 8

3 1 1 I Ordering information 1 Type of orientation H Horizontal V Vertical R Right angled - D m m 2 Housing material 3 Nylon 6.6 (-30 to 130 C) 4 Diecast metal body (-30 to 130 C) 5 Glass tilled Polypropylene (-30 to 110 C) rr: 3 Switching options O S.P.S.T. 120 Vrms/1A (15 W) 1 S.P.S.T. 250 Vrms/1A (15 W) 2 S.P.D.T. 70 Vrms/0.5A (3 W) 3 S.P.S.T. 120 Vrms/3A (100 W) 4 Triac 250Vrms/3A 5 Triac 250Vrms/l A 4 Seal / Grommet S Silicone N Nitrile 5 Mounting options O M16 x 2 internal tit 1 M16 x 2 external tit (compression 2 1/2' NPT external tit 3 1/4' NPT internal fit 4 Universal kit (internal and external assemblies) 6 Termination m PVC insulated leadwire 2 2 m PVC insulated leadwire 3 5 m PVC insulated leadwire 4 2 m two core cable 7, 8, 9 Customer specials Mounting information Care must be taken to ensure that the product is not damaged due to excessive tightening of the fixing nut or threaded bush. Maximum torque limits are shown below. Model Torque limit Maximum container wall thickness External fitting (compression 2.0 lb ft (2.67 Nm) 0.16ins (4 mm) See Note 1 External fitting (1,2" NPT) 5.0 lb ft (6.75 Nm) 1.00ins (25 mm) See Note lb ft (4.0 Nm) 0.394ins (10 mm) Internal tittlng (1/4" NPT) into tapered bush 5.0 lb ft (6.75 Nm) 0.50ins (12.7 mm) through tank wall with nut and 3.0 lb ft (4.0 Nm) 0.12ins (3 mm)see See Note 2 Mounting position Stem position must be vertical ± 15' (vertical & right angle models) Mounting position =" 30' from horizontal I Notes 1. The compression grommet is suitable for a seal pressure psi. 2. When using a 1'2" NPT external fit versión. the container wall thickness must not exceed the length 01 male thread section 01 the switch. Some pipe littings have a small diameter outside the thread area which will restrict entry. This switch is designed to pass through a 1/2' NPT tap drill 0.718" diameter. Because the mounting bush is usually metal and the switch is usually moulded plastic, care must be taken when using the 1/2" or 1/4" NPT versions not to over tighten since this will cause damage to the switch. A sealant such as PTFE tape should always be used on the NPT versions. Ensure that the position orientation on the 1/2' NPT version ís vertical. 3. The Iloat assembly on the horizontal models should never be removed since this will aftect the switching characteristics. 4. To reverse the switching action on horizontal models, simply rotate through 180 observing orientation indicator or. On vertical and right angled models, compress the Iloat stop arms, remove and reverse the Iloat and reassemble. Movement 01 the Iloat in the direction 01 the position indication closes the switch contacts at the end 01 Iloat travel. 9

4 Dimensions in inches (mm) LRN - Horizontal models Fixing nut Container wall /~" // ~~ T (13) (20) / / 1.59.". -c /" (40,_3), ' 2. (4~ (51,59) 1.86 Loek /~ //,.} T / / 1.59 r : / (40.3) ( /, l-1.86 (47,34), 2.03 Container wall (51,59) j Friction reliet I (87,89), Container wall I 1=1 I -J=i;=\\lH--I+H ?,~.3f 0(g2r u ==i, onentation eompression lndicator grommet 3.46 " (87,89) Po Sitio n ~~ ~ ';j8 O!87 orientatron (17.3) (22) indicator ==t ' ~ FIXing nut - Container wall ~ Installatien Hole O O 90 The installation hole should (23) be deburred and elean ~HOle 0 O 65 The installation hole should (16,5) be deburred and elean Installatien hele size External fitting 112" NPT (American National Pipe Thread) 1/4" NPT (American National Pipe Thread) (0.4) hlgh (2.0) wrde -1, (9,0) t 1.59 (40,3) orientation (10.0) Container wall l' (lri2~g7) ' (18.24) Tap drill Mounting bush -BD-+ Mounling bush Loek " --' (17,3) -----r l~"" orientation indicator lnstatlation note shouíc be deburred and elean Hole (14) Installatien he le size 10

5 Dimensions in inches (mm) LRN. Vertical models Thread ml6 x 2 prtch FIxing nut Fnction ~ - -~; ;~~~ cornoressron grommet Positron indication Float ----H7 indication Thread m16 x 2 pitch Fixing nut Container 1 Lock ~ wall washer~~~~~~ 050 n-:::l 3.50 max. 1127)'" I (89) --;; al 2.28 trave! (58) max. (22.2).JY Cl@. ~O~, 0.39A1F l~lole o o.ss (16.5) ~) The installation hole should The installation hole should LRN. Right angle models Lock Thread m16 x 2 pitch Fixing nut Friction relief cornpressron grommet Container wau Posuion indlcation i M')l Hole O 0.90 \~ (23) The mstananon hole should 1<~0.39A1F di ii" (10) Cy <:!i ~ Posnion ~! orientation índícator \~i L ~~Hole O (16.5) The 'nstaltatioo bote should be ceourrec and crean Pos.tion orientatron indicator Float stop O 087 max ),~039A,F ~ da) ~cf cy ~ Posiuon ~ ~ orientation ~ W- mdicator End 1i8W 11

Miniature Liquid Level Sensors

Miniature Liquid Level Sensors C US File No. 1636 (L90200-27) Applications Typical applications include automatic vending machines, photocopiers, small collection tanks, miniature pumping stations, pilot plants and similar small system

More information

CORROSION RESISTANT IN LINE FLOW SWITCHES

CORROSION RESISTANT IN LINE FLOW SWITCHES ULTRASWITCH P20 SERIES CORROSION RESISTANT IN LINE FLOW SWITCHES Magnetically sprung piston provides exceptional reliability FEATURES SUITS TUBES & PIPES 6 TO 20 MM ( 1 /4 TO /4 ) DIA. NO METAL PARTS IN

More information

NCP/NCB/NCS. Magnetic Float Switches. for Liquids

NCP/NCB/NCS. Magnetic Float Switches. for Liquids Magnetic Float Switches for Liquids measuring monitoring analyzing NCP/NCB/NCS Available Materials: Brass, SS, NBR, Polypropylene, and PVC Maximum Pressure: 400 PSIG Maximum Temperature: 300 F Single Point

More information

M-200 Series. High flow, Adjustable flow switch with right-angle flow

M-200 Series. High flow, Adjustable flow switch with right-angle flow Features Field adjustable - Infinite flow range High Repeatability Extremely sensitive Minimum pressure drop Position Insensitive M-200 Series High flow, Adjustable flow switch with right-angle flow Description

More information

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT) 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

Model L-5 & L-5SS LIQUID LEVEL SWITCH. Specific Gravity Compensating

Model L-5 & L-5SS LIQUID LEVEL SWITCH. Specific Gravity Compensating LIQUID LEVEL SWITCH Specific Gravity Compensating Featuring continuously adjustable float buoyancy control to allow use in fluids with specific gravity down to 0.6 Continuous buoyancy control allows switch

More information

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,

More information

Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038

Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038 Commercial Pressure and Float Switches for Power Circuits Catalog 9034CT9701R01/11 Class 9013, 9036, 9037, 9038 TM Table of Contents Table of Contents SELECTION GUIDE PUMPTROL COMMERCIAL PRESSURE SWITCHES...

More information

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) SERIES LOW Flow Positive Displacement Flowmeters To the owner: Please take a few minutes to read through the manual

More information

Plastic tube variable area flowmeter for liquids and gases

Plastic tube variable area flowmeter for liquids and gases Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)

More information

M-50/55 Series. Fixed setting flow switch with in-line flow

M-50/55 Series. Fixed setting flow switch with in-line flow M-50/55 Series Fixed setting flow switch with in-line flow Features Very accurate custom flow settings For corrosive and non-corrosive liquids or gases All-Teflon switch available Senses increasing or

More information

Section 4 - Selection Procedure. Section 5 - Performance Data. Section 6 - Technical Data

Section 4 - Selection Procedure. Section 5 - Performance Data. Section 6 - Technical Data RANGE(S) M Section 4 - Selection Procedure Section 5 - Performance Data Section 6 - Technical Data PUMP RANGE M SECTION 4 MODEL ALL PAGE 1 FEATURES & BENEFITS FEATURE 1. Three basic pump sizes with a capacity

More information

NS FLOAT LEVEL SWITCHES

NS FLOAT LEVEL SWITCHES NS FLOAT LEVEL SWITCHES Flow Pressure Level Temperature measurement monitoring control N1 For All Types of Liquids Mercury-Free Mechanical Switches Polypropylene, PTFE or SS Construction Maximum Temperature:

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Product Bulletin Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve The G196 Series valves use the reliable valve body and magnetic operators from

More information

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE SERIES 223A, 4223A, 323A, 4323A Page 1302.1 Issue B TABLE OF CONTENTS Features & Benefits...2 Jacketing...2 Relief Valve Configurations...3 Porting & Sealing...3 Revolvable Pump Casings...3 Cutaway View

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

FIT-2. Inch. Ø Â" to Ë" O/D tube

FIT-2. Inch. Ø Â to Ë O/D tube For simple and quick assembly of pneumatic circuits. Positive tube connection. Wide range of types available. Reliable and corrosion resistant. Specifications Fluid: Compressed air, nitrogen, inert and

More information

3-Way Linked Globe Valve Assemblies with Linear Series Actuators

3-Way Linked Globe Valve Assemblies with Linear Series Actuators Linked Globe Valve ssemblies with Linear Series ctuators Note: hoose a valve assembly having a close-off pressure capability sufficient for the application. Not all valve body and actuator combinations

More information

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL L-Series: L001, L002, L003, L170, L175, L176, L177, L178, L180, L190 AND L195 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single-Point, Vertically-Mounted Liquid Level Float Switch L001

More information

F300 Pressure Regulator

F300 Pressure Regulator F300 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges P302 has Internal Relief Valve for Overpressure Protection Ideal for Fix Factor Billing The F300 series pilot operated

More information

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

M-100 Adjustable flow switch with right-angle flow

M-100 Adjustable flow switch with right-angle flow M-100 Adjustable flow switch with right-angle flow Operating Instructions and Quick Start Guide Table of Contents Introduction 03 Operation 03 Storage and Handling 03 Installation Instruction 03 Specification

More information

3-way control valve in mixing and diverting design

3-way control valve in mixing and diverting design with electric and pneumatic actuators 3-way control valve in mixing and diverting design 1/2-6 STEVI 450 / 451 Electric actuator Enclosure IP 65 2 torque switches 1 travel switch Handwheel Additional devices

More information

Adjustable Flow Switches

Adjustable Flow Switches Features M- Series High flow, adjustable flow switch with right-angle flow Field adjustable -- infinite flow range High repeatability Extremely sensitive Minimum pressure drop Position insensitive Applications

More information

P99 Pressure Reducing Regulator

P99 Pressure Reducing Regulator P99 Pressure Reducing Regulator Applications City / District gate operation Commercial buildings Boilers, furnace, oven Plant air service Features 5 Pilot choices for low to extra high pressure Up to 1,000

More information

ENVIROMUX Series E-LLS-SF-10/25CM. Stainless Steel Vertical Liquid Level Float Switch. Installation Instruction. Description.

ENVIROMUX Series E-LLS-SF-10/25CM. Stainless Steel Vertical Liquid Level Float Switch. Installation Instruction. Description. ENVIROMUX Series E-LLS-SF-10/25CM Stainless Steel Vertical Liquid Level Float Switch Installation Instruction Description The action of the E-LLS-SF-xxCM Float Switch is straight forward and simple. Mount

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

MODEL L-8 HARWIL CORPORATION 541 KINETIC DRIVE, OXNARD, CA TEL: (805) FAX: (805)

MODEL L-8 HARWIL CORPORATION 541 KINETIC DRIVE, OXNARD, CA TEL: (805) FAX: (805) INSTALLATION INSTRUCTION SHEET GROMMET 'A' GROMMET 'AA' GROMMET 'B' GROMMET 'C' LEADSCREW LEADSCREW NUT STRAIN RELIEF NUT COVER 4 RETAINING SCREWS (NOT SHOWN) MICROSWITCH COMPLETE WITH 2 TERMINALS ADJUSTING

More information

HL (AZH) LIMIT SWITCHES

HL (AZH) LIMIT SWITCHES COMPACT SIZE LIMIT SWITCHES LIMIT SWITCHES U L PRODUCT TYPE 1. Limit Switches Actuator Type Push plunger Roller plunger Cross roller plunger Panel mount push plunger Panel mount roller plunger Panel mount

More information

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL. LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL www.enoscientific.com Eno Scientific PO Box 1586 Hillsborough, NC 27278 USA www.enoscientific.com 910-778-2660 Copyright Notice Copyright 2015 Eno

More information

AF0465-XX SERVICE KITS GENERAL DESCRIPTION MODEL DESCRIPTION CHART OPERATING AND SAFETY PRECAUTIONS THIS MANUAL COVERS THE FOLLOWING MODELS

AF0465-XX SERVICE KITS GENERAL DESCRIPTION MODEL DESCRIPTION CHART OPERATING AND SAFETY PRECAUTIONS THIS MANUAL COVERS THE FOLLOWING MODELS OPERATOR S MANUAL INCLUDING: SERVICE KITS, TROUBLESHOOTING, PARTS LIST, DISASSEMBLY & REASSEMBLY. 4-1/4 AIR MOTORS AF044X-XX (4 STROKE) and AF046X-XX (6 STROKE) Also covers 637489 service kits AF044X-XX

More information

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters To the owner: Thank you for purchasing an OMEGA FPD Series Flowmeter. Please take a few minutes to read through the manual before installing

More information

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications Explosion Proof Adjustable Flow Switch with Right Angle Flow Key Features Field adjustable Infinite flow range Extremely accurate and sensitive Low pressure drop UL recognized for hazardous location ATEX

More information

Liquid Level Switches and Sensors

Liquid Level Switches and Sensors Liquid Level Switches and Sensors Madison Company's comprehensive line of level sensors includes single- and multi-point level switches, continuous level and conductivity sensors and more. The wide selection

More information

Temperature Sensor Series

Temperature Sensor Series GENERAL DESCRIPTION The patented* No. 85026-Series Temperature Sensor contains a two-position valve operated by temperature variations around the integral sensing bulb. It is used to vent or block a pneumatic

More information

UNIVERSAL PRODUCT LINE: STAINLESS STEEL JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

UNIVERSAL PRODUCT LINE: STAINLESS STEEL JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE UNIVERSAL PRODUCT LINE: SERIES 227A, 4227A, 327A, 4327A Section 1702 Page 1702.1 Issue B TABLE OF CONTENTS Features & Benefits...2 Jacketing...2 Relief Valve Configurations...3 Porting & Sealing...3 Revolvable

More information

I N S T R U C T I O N M A N U A L

I N S T R U C T I O N M A N U A L E L E C T R I C L E V E L C O N T R O L S LINC L471 L471SC LV471 L971 SERIES Recognized as a world-class leader in Electric & Pneumatic level control switches, flow indicators, chemical metering pumps,

More information

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching Flow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching GEMS generation of Flow sensors, the RF-25 Series, have been totally re-engineered with a one piece composite rotor, stronger

More information

LIMIT SWITCH BOX MODEL - APL

LIMIT SWITCH BOX MODEL - APL FEATURES AND BENEFITS Enclosure -Solid design, aluminium die-casting IP67 Painting-Powder coating Housing Body- Aluminium die-casting Quick-set Cam-Easy to set, Splined cam Open Yellow, Close Red Various

More information

Extruded Thrusters. Brochure

Extruded Thrusters. Brochure Extruded Thrusters Brochure Chrome plated stainless steel guide shafts optimize bearing performance Mounting flexibility: Through & C-bore Tapped bottom Tapped rear Bottom T-slots Bronze bushing for heavy

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Wide selections of actuators, terminals and bodies to meet any application Excellent environmental resistance Die casting caseiec IP67 Plastic caseiec

More information

Fittings Metal Push-To- Connect Fittings. We make things MOVE

Fittings Metal Push-To- Connect Fittings. We make things MOVE Fittings Metal Push-To- Connect Fittings We make things MOVE Contents 3 Fittings 4 Product Features 4 Push-In Fittings 4 Features and Benefits 5 How it Works 5 Materials of Construction 5 Fluid 5 Operating

More information

APG. LF - Miniature Liquid Level Sensors

APG. LF - Miniature Liquid Level Sensors LF - Miniature Liquid Level Sensors The LF Miniature Liquid Level sensors are designed for reliable operation in small tanks and containers. Their rugged design and multiple configurations make them the

More information

NBK-M - Economical Level Indicator

NBK-M - Economical Level Indicator 316 Stainless Steel Tube Maximum Pressure: 580 PSIG Maximum Temperature: 390 F Measuring Lengths to 9.8 Ft. Optional Switches, Transmitters and Digital Displays Available Economical Rugged Design PRICES

More information

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL L007 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Side-Mounted Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information on the L007 Side- Mounted

More information

UNIVERSAL PRODUCT LINE: STAINLESS STEEL NON-JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE:

UNIVERSAL PRODUCT LINE: STAINLESS STEEL NON-JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE: Page 1701.1 TABLE OF CONTENTS Features & Benefits...2 Port Location Options...2 Model Number Key...3 Standard Materials of Construction...3 Cutaway View & Pump Features...4 Special Materials & Options

More information

UNIVERSAL PRODUCT LINE: CAST IRON NON-JACKETED PUMPS SERIES DESCRIPTION TABLE OF CONTENTS RELATED PRODUCTS OPERATING RANGE:

UNIVERSAL PRODUCT LINE: CAST IRON NON-JACKETED PUMPS SERIES DESCRIPTION TABLE OF CONTENTS RELATED PRODUCTS OPERATING RANGE: Page 1401.1 TABLE OF CONTENTS Features & Benefits...2 Port Location Options...2 Model Number Key...3 Standard Materials of Construction...3 Cutaway View & Pump Features (124A/AE, 4124A/AE, 324A, 4324A)...4

More information

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure Selection Guide VB-8000 Series VB-9313 Series Schneider ElectricVB-8000 Series and VB-9000 Series 2-1/2 to 6 Globe Valves with Schneider Electric NSR Forta M800A and M1500A Actuators Applications Schneider

More information

Armstrong In-Line and Insertion Vortex Flow Meters

Armstrong In-Line and Insertion Vortex Flow Meters Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line

More information

Fluid Dispensing Systems

Fluid Dispensing Systems Fluid Dispensing Systems Automotive Commercial Industrial Centerflo Air Operated Double Diaphragm (AODD) Pumps Pumps Signature Series Product Selection Matrix MAX. FREE FLOW CF10 POLYPROPYLENE AIR INLET

More information

Product Cross Reference

Product Cross Reference AF120 US, AF120-S US AF230 US, AF230-S US AFBUP, AFBUP-S, AFXUP, AFXUP-S Torque 133 in-lb [15 Nm] minimum 180 in-lb. [20 Nm] minimum OPERATION Running Time Noise Level < 75 seconds

More information

VIKING SPUR GEAR SINGLE PUMPS SERIES SG-04, SG-05, SG-07 AND SGN-05, SGN-07 STANDARD CONSTRUCTION FEATURES

VIKING SPUR GEAR SINGLE PUMPS SERIES SG-04, SG-05, SG-07 AND SGN-05, SGN-07 STANDARD CONSTRUCTION FEATURES VIKING SPUR GEAR SINGLE PUMPS FEATURES Section 34 Page 34. SERIES SG-04 and SG-05 Pumps Cutaway View.0 to.2 GPM Sizes (.0 to 2.5 m³/hr) SERIES SG-07 Pump Cutaway View 2.8 to 32.0 GPM Sizes (. to 7 m³/hr)

More information

G96 Series BASOTROL Dual Operator Valve

G96 Series BASOTROL Dual Operator Valve Product Bulletin Issue Date March 5, 2013 G96 Series BASOTROL Dual Operator Valve The G96 Series BASOTROL valves are combination, dual operator, automatic valves available with or without a pressure regulator.

More information

Water Solenoid Valves for Appliances

Water Solenoid Valves for Appliances Water Solenoid Valves for Appliances Features Pilot operated diaphragm water solenoid valves are available in various models and specifications. Available in normally closed, Normally Open and Bistable

More information

Brochure. Compact Cylinders. Setting a new standard for: Quality Reliability Value Global Compatibility

Brochure. Compact Cylinders. Setting a new standard for: Quality Reliability Value Global Compatibility Brochure Compact Cylinders Setting a new standard for: Quality Reliability Value Global Compatibility Actuators - Compact Cylinders How to Order MODEL MACQ - Compact Cylinder MAGNET Blank - No Magnet S

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS Reed Switches and Proximity Sensors 1 REED SWITCHES HIGH POWER 7 UNIVERSAL HIGH POWER & HIGH VOLTAGE 7 Form A Form C Form C Form A Form C 196W 134W 156W 634W 637W 907W 834W 933W

More information

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04 KOBOLD VKA FLOWMETER/SWITCH User Instructions Manual-VKA_03-04 VKA Table of Contents 1.0 General............................................. 1 Specifications..........................................

More information

Sealant & Adhesive Supply Systems with NXT Technology. The Next Generation of Bulk Supply Systems with NXT Technology

Sealant & Adhesive Supply Systems with NXT Technology. The Next Generation of Bulk Supply Systems with NXT Technology Graco Supply Systems Sealant & Adhesive Supply Systems with NXT Technology The Next Generation of Bulk Supply Systems with NXT Technology Dispenses sealants, adhesives and other medium to high-viscosity

More information

LEVEL SWITCH WITH 1 FLOAT

LEVEL SWITCH WITH 1 FLOAT RIL210 LEVEL SWITCH WITH 1 FLOAT LEVEL Immersion level controller with 1 or 2 control points It can be used for dirty liquids, water, petroleum, cutting oils, and tolerates the presence of metal and ferrous

More information

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure.

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure. 13966-300-BM SAFETY MANUAL READ FIRST! IMPORTANT: READ THESE WARNINGS AND SAFETY PRECAUTIONS PRIOR TO INSTALLATION OR OPER- ATION. FAILURE TO COMPLY WITH THESE INSTRUC- TIONS COULD RESULT IN PERSONAL INJURY

More information

Ductile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A

Ductile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A Page 1601.1 TABLE OF CONTENTS Features & Benefits...2 Port Location Options...2 Model Number Key...3 Standard Materials of Construction...3 Cutaway View & Pump Features...4 Special Materials & Options

More information

THZ NEW - In Progress

THZ NEW - In Progress Main applications AC power applications, input-output AC filtering, harsh environment applications Dielectric Polypropylene Electrodes Vacuum deposited metal layers Coating Solvent resistant plastic case

More information

UNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

UNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE Page 1602.1 TABLE OF CONTENTS Features & Benefits...2 Porting & Sealing...2 Jacketing...2 Revolvable Pump Casings...2 Cutaway View & Pump Features...3 Model Number Key...4 Standard Materials of Construction...4

More information

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant Technical Information TI 036D/24/ae Electromagnetic Flow Monitor magphant Flow monitoring in 1 to 80 pipes with conductive liquids Monitoring and measurement Flow monitoring with selectable limit values

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

Fisher YD and YS Control Valves

Fisher YD and YS Control Valves Product Bulletin D100031X012 Fisher YD and YS Control Valves Fisher YD (figure 1) and YS three-way cage-guided valves are designed for throttling or flow-switching (on-off) service, and are available in

More information

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features TAC 1354 Clifford Avenue P.O. Box 2940 Loves Park, Illinois 61132-2940 www.invensysibs.com Two-Way and Three-Way Globe Valve Assemblies with 220 lbf Linear (979 N) Spring Return DuraDrive Actuators Submittal

More information

MINI-NBK ECONOMICAL LEVEL INDICATOR

MINI-NBK ECONOMICAL LEVEL INDICATOR MINI-NBK ECONOMICAL LEVEL INDICATOR Flow Pressure Level Temperature measurement monitoring control N2 316 Stainless Steel Tube Maximum Pressure: 580 PSIG Maximum Temperature: Measuring Lengths to 9.8 Ft.

More information

OEM Series Rotary Actuators. Air-Oil Systems, Inc.

OEM Series Rotary Actuators. Air-Oil Systems, Inc. OEM Series Rotary Actuators OEM Series Rotary Actuators: Table of Contents OEM 1-1/4 (OC) Series...pg. 2 How to Order: OEM 1-1/4 (OC) Series...pg. 3 Dimensional Data...pg. 4 OEM 2-1/2 (OT) Series...pg.

More information

Y610A, Y611A, and Y612A Series Vacuum Service Equipment and Relief Valves

Y610A, Y611A, and Y612A Series Vacuum Service Equipment and Relief Valves Y610A, Y611A, and Y612A Series Vacuum Service Equipment and Relief Valves July 2013 W1094_1 Figure 1. Type Y610A or Y610AP Vacuum Breaker Introduction The Y610A, Y611A, and Y612A Series devices (Figures

More information

INSTALLATION INSTRUCTIONS SWITCH HOUSING SUPPLIED ONLY AS AN ASSEMBLY OF ENCAPSULATED SWITCH & LEADS. FLOAT SUPPLIED ONLY WITH ENCAPSULATED MAGNET.

INSTALLATION INSTRUCTIONS SWITCH HOUSING SUPPLIED ONLY AS AN ASSEMBLY OF ENCAPSULATED SWITCH & LEADS. FLOAT SUPPLIED ONLY WITH ENCAPSULATED MAGNET. INSTALLATION INSTRUCTIONS SWITCH HOUSING, L-40N NORYL (PPO) SWITCH HOUSING, L-40VCR FORTRON (PPS) CERAMIC MAGNET BUSHING, L-40N NORYL (PPO) L-40VCR FORTRON (PPS) LEADS 24 LONG OR LONGER REED SWITCH FLOAT,

More information

TECHNICAL SPECIFICATIONS. Measuring Accuracy ±2% of full scale. Repeatability ±0.5% of full scale

TECHNICAL SPECIFICATIONS. Measuring Accuracy ±2% of full scale. Repeatability ±0.5% of full scale TECHNICAL SPECIFICATIONS Measuring Accuracy ±2% of full scale Repeatability ±0.5% of full scale Flow Measuring Range 1/2 porting: 0.5 15 GPM (2 60 LPM) 3/4 1 porting: 1.5 50 GPM (60 200 LPM) Turn Down

More information

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths

More information

TK-6024, TK-6124, TK-8024, TK-8124

TK-6024, TK-6124, TK-8024, TK-8124 TK-6024, TK-6124, TK-8024, TK-8124 Pneumatic Bulb Thermostats General Instructions APPLICATION For proportional temperature control of pneumatic valves and actuators to maintain air or liquid temperatures

More information

Level switches Series LC40 Float level switch for liquids

Level switches Series LC40 Float level switch for liquids Level switches Series LC40 Float level switch for liquids Simple and robust construction Versatile and easily adaptable to the different control positions of the industrial processes Side or top of the

More information

M-61-F. Fixed Set Point Flow Switch. Description. Operating Principle. Application Examples.

M-61-F. Fixed Set Point Flow Switch. Description. Operating Principle. Application Examples. M61F AllPFA molded fi xed setting fl ow switch with inline fl ow and integral fl are fi ttings For corrosive and noncorrosive liquids or gases Senses increasing or decreasing flow Custom flow settings

More information

MINI BY-PASS LEVEL INDICATOR

MINI BY-PASS LEVEL INDICATOR MINI BY-PASS LEVEL INDICATOR APPLICATIONS AND FEATURES It can be easily observed from the change of the flag color. Safer device comparing to glass type level gauge. Compact type, easy to install. Magnetic

More information

VERTICAL TYPE LIMIT SWITCHES (INCLUDES LAMP TYPE)

VERTICAL TYPE LIMIT SWITCHES (INCLUDES LAMP TYPE) VERTICAL TYPE LIMIT SWITCHES (INCLUDES LAMP TYPE) Limit Switches General use vertical limit switch. Type with a lamp which makes maintenance convenient; either a neon AC powered lamp or an LED DC powered

More information

KDM ARMORED FLOW METER & SWITCH

KDM ARMORED FLOW METER & SWITCH KDM ARMORED FLOW METER & SWITCH Flow Pressure Level Temperature measurement monitoring control S2 Short Installation Length SS, PTFE or Hastelloy Wetted Parts Analog Output Available 110 F to + 390 F Temperature

More information

L312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Multi-Point, Vertically-Mounted Liquid Level Float Switch READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information on the Multi-

More information

PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE DATASHEET

PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE DATASHEET PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE DATASHEET Pacbrake PowerHalt 3 Air Intake Emergency Shut-Off Valve is an electronically controlled emergency engine shut down system which forces engine shut down

More information

CASH VALVES TYPE G-4 PRESSURE REGULATORS

CASH VALVES TYPE G-4 PRESSURE REGULATORS A self-actuating pilot operated pressure reducing valve handling air, gas and steam and accurate to within ½% up to 3" and 1% for sizes to 6 FEATURES Extremely compact design enables use of a smaller regulator.

More information

BGD258 Series BASOTROL CE Approved Class A Gas Valve

BGD258 Series BASOTROL CE Approved Class A Gas Valve Product Bulletin Issue Date May 21, 2010 BGD258 Series BASOTROL CE Approved Class A Gas Valve The BGD258 Series multi-function gas control valve works in conjunction with an electronic sequence control

More information

Pneumatic Division North America Richland, MI 49083

Pneumatic Division North America Richland, MI 49083 Pneumatic Division North America Richland, MI 08 Installation Instructions: V-0P /8" Valvair II/A Series Valves Single Operated ISSUED: May, 00 Supersedes: November, 8 ECN #6 Rev. 6 WARNING To avoid unpredictable

More information

Male stud fittings. Male stud elbow. Fluid... Working pressure... Vacuum level... Rated temperature...

Male stud fittings. Male stud elbow. Fluid... Working pressure... Vacuum level... Rated temperature... FITTINGS Push - in fittings 431 Series Fluid... Working pressure... Vacuum level... Rated temperature... Torque... Standards... Materials... Compressed air Max. 20 bar (290 psi) 55 mm Hg vacuum (99 %)

More information

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Flowline, Inc. 10500 Humbolt Street Los Alamitos, CA 90720 Tel: (562) 598-3015

More information

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching ROTORFLOW INTRODUCTION RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching Bright, visual indication with choice of pulsed DC output, or adjustable 1 amp switched output

More information

RIM20 Rotor Insertion Flowmeter

RIM20 Rotor Insertion Flowmeter Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Picoflex. 1.27mm IDT Connector System for Ribbon Cable Applications

Picoflex. 1.27mm IDT Connector System for Ribbon Cable Applications Picoflex 1.27mm IDT Connector System for Ribbon Cable Applications Picoflex Markets & Applications The versatile Picoflex IDT connector system is ideal for a broad range of applications across all market

More information

High-Flow Stainless Tubes. Standard Tubes BRASS 18 LONG STAINLESS STEEL 18 LONG H11. All stainless construction for high strength and durability

High-Flow Stainless Tubes. Standard Tubes BRASS 18 LONG STAINLESS STEEL 18 LONG H11. All stainless construction for high strength and durability High-Flow Stainless Tubes H11 ll stainless construction for high strength and durability Use with all PCS cascades J in part number indicates next largest thread TUE TUE L = 12 18 24 36 HF093T-.090.076

More information

Installation & User Instructions

Installation & User Instructions Installation & User Instructions 16/25A Digital Dimmer (416/425) INTRODUCTION The 416 and 425 are Digital Dimmers capable of dimming a single channel with total loads of up to 16A and 25A respectively.

More information

Class 9038 Type A Mechanical Alternator, Open Tank

Class 9038 Type A Mechanical Alternator, Open Tank Selection Guide Float Switches Class 9038 Type A Mechanical Alternator, Open Tank Type of Installation Product Features Horsepower rated 4-pole switch Standard action contacts close on liquid rise Reverse

More information

DEADMAN AND WATER CONTROL SYSTEMS

DEADMAN AND WATER CONTROL SYSTEMS DEADMAN AND WATER CONTROLS _ BULLETIN 67 (07/05) DEADMAN AND WATER CONTROL SYSTEMS DEADMAN HANDLE AND CORD DEADMAN CONTROL SYSTEM WATER CONTROL SYSTEM COMBINATION DEADMAN AND WATER CONTROL SYSTEM * * *

More information

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual Switch-Tek Horizontal, Vertical & Float-Point Float Switches AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA

More information

CM707 (UK Version) PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM707 (UK Version) PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM707 (UK Version) PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET The CM707 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It

More information

10 S e r i e s PRESSURE SWITCH. features

10 S e r i e s PRESSURE SWITCH. features 10 S er i es 10 S e r i e s PRESSURE SWITCH features Tamper-Resistant Field Adjustment Adjustable Ranges from 4 to 7500 PSI (0,3 to 517,1 Bar) Choice of 7 Electrical Terminations 1-1/4" Diameter Height

More information

PSF50 Paddle flow switch

PSF50 Paddle flow switch Paddle Flow Switch Paddle Flow Switch PSF50 Paddle flow switch Paddle flap flow / no flow switch Economically priced flow/no flow paddle operated flow switch. Simple and reliable design for liquids up

More information

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available Explosion Proof Flowswitch with In-line Flow Key Features Well suitable for corrosive and noncorrosive liquids or gases UL recognized for hazardous location ATEX certified for intrinsic safety and encapsulation

More information

Turn-Dex Rotary Vane Actuators

Turn-Dex Rotary Vane Actuators Turn-Dex Rotary Vane Actuators Turn-Dex: Table of Contents Turn-Dex Turn-Dex 1-1/4 Bore pg. 2 How to Order pg. Dimensional Data pg. 4 Turn-Dex 2-1/2 Bore pg. 5 How to Order pg. 6 Dimensional Data pg. 7

More information

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves VFB30 Series Issue Date February 1, 2016 20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves Low Torque Facilitates the use of smaller, less expensive directmount rotary-motion actuators Extends

More information