OIL TREATMENT ARRAS MAXEI

Size: px
Start display at page:

Download "OIL TREATMENT ARRAS MAXEI"

Transcription

1 I-BETH13GB-A page 1/5 TECHNICAL DESCRIPTION OF THE STANDARD PLANTS TYPE MAS kW 500m 3 /h SUMMARY: Principle of operation 2 Main characteristics 2 Components of the plant 2 Description of the plant 3 Operating diagram 4 Optional features 5 PREAMBLE The use with confidence of the dielectric fluids in the transformers, circuit breakers, and other types of electrical equipment depends upon some of their basic characteristics, which can affect the general operating efficiency of the electrical equipment. In order to ensure manifold functions such as an insulant, a coolant and an extinguishing medium, these dielectric fluids must have some basic properties, and especially a high dielectric strength. Now, in service, the dielectric fluids properties may be affected by the appearing of oxidation, condensation and other contaminants such as water, solid impurities and dissolved gases. Working on the principles of filtration, dehydration and vacuum degasification, MAXEI Industries Electriques oil treatment plants are particularly recoended to maintain, dry and fill your transformers and circuitbreakers. By removing the impurities, dissolved moisture and gases, they indeed enable to restore the oil dielectric properties and to extend the useful life of your electrical equipment. Used and well-known all over the world for their performance, reliability and ease of operation, our standard plants are now enriched with our latest technological achievements. Automated, fitted with remote control or telecontrol systems, our oil treatment plants are more and more autonomous, which insure you increased productivity. MAS 6000 on road trailer with metallic cover Oil treatment The oil treatment plants ARRAS MAXEI has been designed to treat dielectric oil having a 50 ppm moisture content and a dissolved gas content of approx. 10% by volume before being treated. After getting the optimal treatment conditions, the clean treated oil goes out after 1 pass at a maximum temperature of 70 C with a moisture content below 5 ppm* and a dissolved gas content of approximately 0,1% by volume*. The breakdown voltage of the oil will be in excess of 75 kv after treatment. An oil at 20 ppm will go out at 3 ppm* after 1 pass. The above figures are reached with oils having a 10-2 mbar distillation curve at a temperature of 80 C. KV Evolution of the moisture content and o f the dielectric 100 diélectric Moisture content ,1 0,01 Comparison betwenn vapor and liquid phases of moisture and dielectric oil EAU Lliquid water Vapor water T C Liquid oil HUILE Vapor oil * : Theoretical values depending on the measuring device accuracy and ranging from 2 to 5 ppm

2 I-BETH13GB-A page 2/5 Principle of operation Road trailer Low speed trailer Plant with metallic cover Plant with tarpaulin The dielectric fluid enters in the plant through an inlet strainer, and then passes through an inlet oil pump and into an oil heater, where it is heated by iersion heaters. After a fine filtration on cartridge, the dielectric fluid is sprayed into a vacuum chamber on a basket of «Raschig» rings. Finally, after the contaminants are eliminated, the clean treated fluid flows through the outlet oil pump. Foam regulation system Transformer insulating system High level detection system Main characteristics Nominal flow* during treatment in l/h 8000 Heating power in kw 110 Total power in kw 130 Filtration** by cartridges in nominal µm 1 Limit vacuum against closed suction in mbars 0,05 Vacuum during treatment in mbars 0,5 to 2 * : Approximate values. ** : Consumable cartridge with filtration expressed in µm nominal. All our plants are equipped in standard with tropicalized electrical material, for a feeding tension 400 Volts 3 phases 50 Hz and auxiliary operation in 220 Volts by transformer. (Special tensions quoted on demand) Components of the plant Voltmeter / Ampere meter Telecontrol 1 inlet oil motor-pump 1 direct electrical heater with 2 working temperatures 1 cartridge filter 1 dehydration tank 1 outlet oil vacuum motor-pump 1 double-staged vacuum motor-pump 1 set measuring, controlling, alarming, and regulating apparatus 1 control panel 1 set of pipes, valves and accessories 3 lifting rings placed on upper part of the of the degasification unit The standard plant is installed on a section iron plate with retention tray and maintenance wheels.

3 I-BETH13GB-A page 3/5 Description of the plant Heater and oil filtering system. Maxi flow of the pump in l/h Pump type Centrifugal Height of discharge in mce 40 Motor power in kw 4 1) Inlet oil motor-pump The oil inlet suction of the standard oil treatment plants are equipped with a syetrical connection (like French fire system), a strainer filter, an insulation valve, an inlet oil motor-pump and an oil sampling valve also serving as an heater drain. Pump building Cast iron/steel Rotation speed in rpm 1500 Connection diameter in 40 Total heating power in kw 110 Number of thermo dippers 14 Power of an element kw 7,8 Auxiliary heating connection 40 Number of cartridges 12 Filter building Cast iron/steel Clogging control Pressostat 2) Heater The motor-pump outlet of the standard oil treatment plants are equipped with a heater made of pipe stub heating casing, equipped with flanged iersion heater. This heater has two working temperature. The heater outlet is equipped with a safety valve adjusted at 4 bars, an overheating safety thermostat, a temperature regulation probe PT100, a heater by-pass and a manometer -1 / +5 bars. 3) Filtering system The standard oil treatment plants are equipped with a consumable cartridge filter with 1 µm nominal filtration. The filter, equipped of a clogging control, is connected to the dehydration tank. Oil degazing under vacuum. Flow of primary pump in m 3 /h 240 Limit vacuum in mbar 0,08 Motor power in kw 5.5 Rotation speed in rpm 1450 Oil capacity in litre 8,5 Flow of roots pump in m 3 /h 505 Roots motor power in kw 2,2 Rotation speed in rpm 3000 Oil capacity in litre 2,2 Vacuum measure Pirani Auxiliary vacuum connection 50 4) Dehydration tank The standard oil treatment plants are equipped with a cylindrical steel dehydration cell. It includes a spraying blockhead and a basket of dehydration rings. The upper part of the cell is equipped with an inlet oil connection, a connection to the vacuum pump, a vacuum indicator 1000 to 0 mbar and a vacuum regulation valve. The collar is equipped with a level sensor, a low tension headlight window to look at the lower part of the cell and a foam regulation system. The lower part is equipped with a flow regulation tube and a draining valve. 5) Vacuum motor-pump The standard oil treatment plants are equipped with a double-staged group composed of a pump with pales, greasing through oil circulation with filter, antireturn valve and air ballast and of a Roots pump. The group is connected to the dehydration cell by a pipe equipped with a safety valve, an insulating valve, a Pirani vacuum gauge with display and an exhaust electro-valve of the group. Maxi flow of the pump in l/h Pump type Centrifugal Height of discharge in mce 40 Motor power in kw 5,5 Rotation speed in rpm 1500 Pump building Cast iron/bronze Oil outlet. 6) Outlet oil vacuum motor-pump The outlet discharge of the standard oil treatment plants are equipped with an outlet oil vacuum motor-pump, a valve of oil sampling, an anti-return valve, an insulation valve and a syetrical connection (like French fire system). Connection diameter in 50

4 I-BETH13GB-A page 4/5 7) Control panel The standard oil treatment plants are equipped with an industrial water proof type cabinet in painted steel, with contactors, relays, fuses, connectors and wires necessar for the equipment running. On the door, there s the buttons and warning lights of the different equipment components. 8) Finishing painting The standard oil treatment plants are painted in white (RAL9002). 9) Dimensions Length in Width in High in Weight in kg Plant on platform Not proposed Plant on skid Plant on cart 3165** Plant on cart with tarpaulin 3165** Plant on cart with metallic cover 3165** Plant on road trailer with tarpaulin 3800** * Plant on road trailer with metallic cover 3800** * * : The weight is not higher for the road trailers equipped with tarpaulin or metallic cover ** : The lengths are given without the draw bar All characteristics may be modified without any prior notice.

5 I-BETH13GB-A page 5/5 Optional features Présentation 1) ROAD TRAILER WITH CEE AGREMENT In order to be portable type, the oil treatment plant can be installed on a road trailer to move the plant by road at a maximum speed of 90 km/hr. The trailer is equipped with rear lights in accordance with the EU regulations of road code. The whole installation is coissioned by the French government vehicle testing service to be allowed to circulate in France and European countries. The road trailer is composed of : - 1 frame made of iron steel, 1 steel plate, - 1 trailer coupling, adjustable vertically, with standard ring towing eye (BNA 68 42, inside diameter of the ring : 68 ), - 1 double wheel axle (4 wheels) or 2 axles with 4 wheels, placed at the centre, spring suspension, 1 air braking with ABS system in accordance with the EU regulations, - 1 park brake, 1 spare wheel, 1 adjustable front stand, 2 anti-roll stand. 2) ROAD TRAILER WITHOUT CEE AGREMENT In order to be portable type, the oil treatment plant can be installed on a road trailer to move the plant by road at a maximum speed of 90 km/hr. The trailer is equipped with rear lights in accordance with the EU regulations of road code. The whole installation is not coissioned by the French government vehicle testing service and is not allowed to circulate in France and European countries. The road trailer is composed of : - 1 frame made of iron steel, 1 steel plate, - 1 trailer coupling, adjustable vertically, with standard ring towing eye (BNA 68 42, inside diameter of the ring : 68 ), - 1 double wheel axle (4 wheels) or 2 axles with 4 wheels, placed at the centre, spring suspension, 1 air braking system not suitable with EU regulations of road code, - 1 park brake, 1 spare wheel, 1 adjustable front stand, 2 anti-roll stand. 3) CART The oil treatment can be installed on a cart with full tyres (maxi speed: 20 km/h). 4) TARPAULIN PROTECTION The plant can be equipped with a tarpaulin, which protects it from the bad weather. It can be opened on the four sides to enable the access to the components of the plant. 5) METALLIC COVER PROTECTION The plant can be equipped with a metallic cover, which protects from the bad weather. It is made of iron steel. Doors closing per key are installed to enable the access to the main components of the plant. Control process Process measures 1) INLET ELECTRO VALVE This option enables, in case of incident or any sudden treatment stopping (power cut), to insulate the plant from the electric appliance to be treated and thus to prevent from dangerous oil flowing into the oil treatment plant. 2) FLOW INVERSION OF OIL You can invert the flow direction in the transformer without disconnecting the inlet and outlet oil hoses. 3) HIGH LEVEL DETECTION SYSTEM This option enables the automatic stop of the plant, when the valve, which protects the vacuum pump, is full. This reinforced safety and avoids the transfer of the condensates in the vacuum pump. 4) VOLTMETRE / AMPEREMETRE 5) SAFETY LEVEL CONTROL ON TRANSFORMER This option is installed on the upper part of the transformer to control the variations of the oil level in this one. 6) TRANSFORMER INSULATION SYSTEM This option insulates the transformer in case of problem detected on the oil treatment plant. 1) ONLINE WATER CONTENT MEASURING OR ONLINE PARTICLES MEASURING 2) 6 CHANNEL NUMERIC RECORDER (to record temperatures, vacuum, water content, etc.) 3) OPERATOR LESS FONCTIONNING OR AUTOMATIC FONCTIONNING Transformer drying 1) CONDENSOR AND COOLING GROUP This option enables an optimal protection of the pump group in case of high water content treatment. 2) TRANSFER PUMP This option enables to increase the hoses length between the plant and the transformer. 3) HIGHER HEATING POWER The standard heating power of the oil treatment plants has been calculated for a weight ratio between oil and transformer about 4. In case of a higher ratio, we recoend to increase the heating power of the plant. 4) CONNEXION FEATURES AND ACCESSORIES 5) PULVERIZATION Telecontrol TELECONTROL GSM telecontrol or Monitoring GSM on oil treatment.

Technical Specification Number S121 for Insulating Oil Purification Plant, Type E rev Q CONTENTS

Technical Specification Number S121 for Insulating Oil Purification Plant, Type E rev Q CONTENTS CONTENTS 1. GENERAL 2. SCOPE OF SUPPLY 3. DUTY AND PERFORMANCE 4. PROCESS DESCRIPTION 5. MAIN COMPONENTS 6. INSTRUMENTATION 7. ALARMS AND INTERLOCKS 8. OPTIONAL EQUIPMENT AND ACCESSORIES 9. COMMISSIONING

More information

LUBEMASTER Standard model. The Lubemaster OS600 Centrifugal Oil Filtration Unit standard model comes complete with :

LUBEMASTER Standard model. The Lubemaster OS600 Centrifugal Oil Filtration Unit standard model comes complete with : LUBEMASTER Standard model The Lubemaster OS600 Centrifugal Oil Filtration Unit standard model 300L Holding Tank 3 Pneumatic tyres Approximate Dimensions: H1700 xl1400 xw600 cm Approximate Weight : 550

More information

TRANSFORMER OIL FILTRATION PLANT 6000 LPH CAPACITY TRANSFORMER OIL FILTRATION PLANT LPH CAPACITY

TRANSFORMER OIL FILTRATION PLANT 6000 LPH CAPACITY TRANSFORMER OIL FILTRATION PLANT LPH CAPACITY SHEET 1 of 9 - The Plant shall be suitable for treating Transformer & Switchgear oil by first heating it and then passing it through specially designed filter and then subjecting it to high vacuum treatment

More information

250300APR DC coated and 316 stainless steel

250300APR DC coated and 316 stainless steel 250/300mm APR Self Priming (dc) Series Pump Heavy Duty Applications Specialised Design Features Suction flange - heavy duty 300 mm or 250 mm hole patterns to AS2129 E Discharge flange - heavy duty 250

More information

High vacuum transformer oil purification (HVTOPS) & Dielectric OIL Purifier System (DOPS)

High vacuum transformer oil purification (HVTOPS) & Dielectric OIL Purifier System (DOPS) High vacuum transformer oil purification (HVTOPS) & Dielectric OIL Purifier System (DOPS) For achieving optimal fluid dielectric strength to meet or exceed stringent oem specifications Two ways to quickly

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model: IIV85 Generator set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE IVECO MODEL N45TM1A CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1)

More information

[Small diaphragm vacuum pumps]

[Small diaphragm vacuum pumps] [Small diaphragm vacuum ] The small vacuum shown on this page produce vacuum using a diaphragm. They can be used either as vacuum pump or as a small compressor, and they are able to deliver 100% oil-free

More information

Small diaphragm vacuum pumps

Small diaphragm vacuum pumps Small diaphragm vacuum pumps Model Capacity Max vacuum Max pressure Power Input Weight lt/1 mbar bar watt A kg. H 35 MDR 18,0 300 1 30 0,45 1,3 H 40 DMR 17,5 300 1 38 0,40 1,6 H 35 MRD 18,0 300 1 30 0,45

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42 TECHNICAL SPECIFICATIONS Model: II-044 Gen set with manual control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE FPT MODEL F32SM1A CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 40

More information

Inverter scroll compressors VZH single and manifold

Inverter scroll compressors VZH single and manifold Application guidelines Inverter scroll compressors VZH088-117-170 single and manifold R410A http://cc.danfoss.com Content VZH088-117-170 - single compressors... 4 VZH088-117-170 - hybrid manifolding...

More information

GMK EV SERIES. Single Stage Oil Sealed Rotary Vane Pump

GMK EV SERIES. Single Stage Oil Sealed Rotary Vane Pump GMK EV SERIES Single Stage Oil Sealed Rotary Vane Pump EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum needs. Eurovacuum

More information

SUCTION FILTRES. 3D drawings available at

SUCTION FILTRES. 3D drawings available at SUCTION FILTRES FCL IN-LINE SUCTION FILTRES, WITH PAPER CARTRIDGE PAG..01.02 PAPER FILTERING CARTRIDGES FOR FCL FILTRES PAG..02 FB SUCTION FILTRE WITH METAL CARTRIDGE PAG..03.10 STAINLESS STEEL MESH FILTERING

More information

JUNG PUMPEN US SUBMERSIBLE DRAINAGE PUMPS

JUNG PUMPEN US SUBMERSIBLE DRAINAGE PUMPS APPLICATION The centrifugal submersible drainage pumps US 62-251 can be used wherever sewage water with solids up to 10 mm particle size occurs, e.g. in collecting sumps for ground water, or in permanent

More information

AUE-AUD-AU2E AU2D-AUED

AUE-AUD-AU2E AU2D-AUED AUE-AUD-AU2E AU2D-AUED EN12845 Fire Pump Stations Designation of AUE 120 / 100 - N 80-250/75 + DJ MV 708 AUE: One electric main pump + jockey 120: Rated Flow (m 3 /h) 100: Rated Pressure (Hm) N 80-250/75:

More information

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents. PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the

More information

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07. Air Cooled Water Chillers CLS 182 to 602 41 to 150 kw Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.04 R Specifications General characteristics The CLS air cooled water

More information

ERMA FIRST BALLAST WATER TREATMENT SYSTEM

ERMA FIRST BALLAST WATER TREATMENT SYSTEM ERMA FIRST BALLAST WATER TREATMENT SYSTEM The ERMA FIRST Ballast Water Treatment is an autonomous advanced system, developed and designed to meet the D-2 standards of the International Convention for the

More information

Series PCS Portable Coalescence Separation Oil Purifier

Series PCS Portable Coalescence Separation Oil Purifier Series PCS Portable Coalescence Separation Oil Purifier ATTN: Mr. Kevin Dube Tel/Fax: 0086 23 8823 9845 Mob/WhatsApp: 0086 135 2739 0908 Email: sales@fuootech.com, kevinnchiang@gmail.com Add: No.5 Hongshi

More information

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

HYDROCIAT LW R134a. Water cooled chillers USE RANGE Screw compressors CIAT direct expansion shell and tubes evaporator equipment (High Power System) Cooling or heating Heat recovery ENVIRONMENTALLY HFC R134a PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28. ,QGXVWULDO#*HQVHW '3#5: 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.5kW Generator set consisting of engine and alternator mounted

More information

Transformer Components & Accessories

Transformer Components & Accessories Transformer Components & Accessories Brian Brinson Mechanical Design Manager brian.brinson@spx.com Agenda 1. Standards / Equipment Overview 2. Bushings 3. Arresters 4. Cooling Equipment 5. Instrument Transformers

More information

PRESS P/N - P/N ECO SERIES

PRESS P/N - P/N ECO SERIES The PRESS P/N series of burners covers a firing range from 800 to 5130 kw. They have been designed in three versions for use in commercial and industrial installation, to burn different oil viscosity from

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

ROGERS MACHINERY COMPANY, INC

ROGERS MACHINERY COMPANY, INC KOBELCO KNW SERIES Sample Specifications AIR-COOLED, OIL-FREE AIR COMPRESSOR Frame 0, 1, 2 50 500 HP ROGERS 2110_KA.doc Effective: 03-24-17 Supersedes: 04-06-15 Page 1 of 9 1. SPECIFICATIONS SCOPE 1.1

More information

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160) FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioning 100% outside air About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling

More information

Off-Line Filtration OFF-LINE FILTRATION

Off-Line Filtration OFF-LINE FILTRATION Off-Line Filtration: Where and Why Used The Donaldson Filter Cart, Filter Panel and Filter Buddy offer convenient off-line filtration, flushing and fluid transfer.* Use them with your in-plant machinery

More information

Atlas Copco Generators QAS kva 50 Hz dual frequency. For your peace of mind

Atlas Copco Generators QAS kva 50 Hz dual frequency. For your peace of mind Atlas Copco Generators QAS 14-300 14-300 kva 50 Hz dual frequency For your peace of mind QAS generators: 1 Supersilenced canopy QAS generators are whisper quiet. The foam lined canopy is exceptionally

More information

ENGINE COOLING GROUP CONTENTS RADIATOR GENERAL DESCRIPTION SPECIAL TOOLS THERMOSTAT

ENGINE COOLING GROUP CONTENTS RADIATOR GENERAL DESCRIPTION SPECIAL TOOLS THERMOSTAT 14-1 GROUP 14 CONTENTS GENERAL DESCRIPTION 14-2 SPECIAL TOOLS 14-3 DIAGNOSIS 14-3 INTRODUCTION 14-3 TROUBLESHOOTING STRATEGY 14-3 SYMPTOM CHART 14-4 SYMPTOM PROCEDURES 14-4 ON-VEHICLE SERVICE 14-17 ENGINE

More information

MODEL CMA-180UC PARTS MANUAL Rev 1.19

MODEL CMA-180UC PARTS MANUAL Rev 1.19 MODEL CMA-180UC PARTS MANUAL Rev 1.19 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS MODEL CMA-180UC 1. PARTS

More information

重庆恩氏过滤设备制造有限公司 Sino-NSH Oil Purifier Manufacture Co., Ltd. domestic.

重庆恩氏过滤设备制造有限公司 Sino-NSH Oil Purifier Manufacture Co., Ltd. domestic. Brief Introduction is a high-tech Company which is engaged in researching, developing and manufacturing lubrication purification equipme nt. Its parent company, Sino-NSH High-Tech Company, was established

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation,

More information

SCHOPF F396C. Aircraft Towing Tractor TECHNICAL DATA & CONFIGURATION

SCHOPF F396C. Aircraft Towing Tractor TECHNICAL DATA & CONFIGURATION SCHOPF F396C Aircraft Towing Tractor TECHNICAL DATA & CONFIGURATION TECHNICAL DATA Operating weights 45,000 / 50,000 / 55,000 / 60,000 / 70,000 kg Tyres, front + rear 16.00 x 25 18.00 x 25 (70,000 kg)

More information

SELF-CLEANING FILTER

SELF-CLEANING FILTER SELF-CLEANING FILTER CT0126.0_00 UK November 2008 PRODUCTION RANGE Connections Standard Mesh [μm] Size Code Kv [m³/h] THREADED FF UNI-EN-ISO 228 100 3/8 126.03.10 1,80 1/2 126.04.10 3,10 3/4 126.05.10

More information

PAS 150HF 300 DATA SHEET

PAS 150HF 300 DATA SHEET PAS 150HF 300 DATA SHEET PAS 150HF 300 Diesel - Qmax 510 m³/h (2,250 USgpm) - Hmax 51 m (167 ft) PAS 150HF 300 Liquid cooled engine Benefits PAS MF - Vacuum prime centrifugal pumps The pump system consists

More information

PAS 100MF 250 DATA SHEET

PAS 100MF 250 DATA SHEET PAS 1MF 5 DATA SHEET PAS 1MF 5 Diesel - Qmax 5 m³/h (1,1 USgpm) - Hmax 36 m (118 ft) PAS 1MF 5 Liquid cooled engine PAS 1MF 5 Air cooled engine Benefits PAS MF - Vacuum prime centrifugal pumps The pump

More information

TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25

TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25 TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25 (505)872-0037 The TRIVAC NT is the latest generation of well-proven rotary vane pumps. The performance and handling characteristics of

More information

ROGERS MACHINERY COMPANY, INC

ROGERS MACHINERY COMPANY, INC KOBELCO KNW SERIES Sample Specifications ROGERS MACHINERY COMPANY, INC WATER-COOLED, OIL-FREE AIR COMPRESSOR Frame 00 20-50 HP 2110_00.doc Effective: 03/24/17 Supersedes: 10-11-13 Page 1 of 8 1. SPECIFICATION

More information

Heating and Gas Installations - December 2014

Heating and Gas Installations - December 2014 This is an example of good practice maintenance specifications. It is not exhaustive and should only be used to assist with facilities management or specification of a maintenance contract. Emergency Gas

More information

ABS submersible sewage pump AFP

ABS submersible sewage pump AFP BS submersible sewage pump FP - Robust, reliable submersible pumps from. to kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and municipal areas in accordance

More information

Storage connection with 5 meter long rubber hose DN8, DILO coupling DN8, ball valve DN R050 and five different SF 6

Storage connection with 5 meter long rubber hose DN8, DILO coupling DN8, ball valve DN R050 and five different SF 6 For liquid SF 6 storage B095R12 Compressor unit Operating voltage: 220-240 V / 50-60 Hz alternating current B095R12S15 Compressor unit Operating voltage: 110-127 V / 50-60 Hz alternating current Dimensions:

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION Electrical Energy Storage Tester EEST-511-S Semi-Automatic Charge-Discharge Battery Bench 1 channel 50 V / 100A (Ni-CD, Pb, Ni-Mh, Li-ion...) TECHNICAL DESCRIPTION To buy, sell, rent or trade-in this product

More information

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA 1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous

More information

PAS 300MF 390 DATA SHEET

PAS 300MF 390 DATA SHEET DATA SHEET Diesel - Qmax 1,13 m³/h (4,98 USgpm) - Hmax 29,5 m (97 ft) Liquid cooled engine Benefits PAS MF - Vacuum prime centrifugal pumps The pump system consists of a centrifugal pump and a SuperDuo

More information

CGA CXA VGA VXA CG-PRC006-E4

CGA CXA VGA VXA CG-PRC006-E4 Cooling Only or Reversible Air Cooled Water Chiller CGA 075-100-120-150-200-240 CXA 075-100-120-150-200-240 VGA 075-100-120-150-200-240 VXA 075-100-120-150-200-240 Designed with your needs in mind TRANE

More information

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw The Riello 40 F series of one stage light oil burners, is a complete range of products developed to respond to any request for light industrial applications. The Riello 40 F series is available in three

More information

Year of manufacture 2007 Control HEIDENHAIN itnc 530 Machine number X mm / Y mm / Z mm C - +/- 220 / B - +/- 110

Year of manufacture 2007 Control HEIDENHAIN itnc 530 Machine number X mm / Y mm / Z mm C - +/- 220 / B - +/- 110 EiMa GAMMA T LINEAR 5 axes portal machining center In excellent conditions Manufacturer Model EiMa GAMMA T LINEAR Year of manufacture 2007 Control HEIDENHAIN itnc 530 Machine number 11615 Travels X 3.700

More information

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES This generator set is available with CE certification. 3 Phase Ratings, 50 Hz, PF 0,8 Rating (ESP) Prime Rating (PRP) Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 Rating (ESP): Prime

More information

MODEL CMA-180UC PARTS MANUAL Rev 1.19A

MODEL CMA-180UC PARTS MANUAL Rev 1.19A MODEL CMA-180UC PARTS MANUAL Rev 1.19A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 wwwcmadishmachines.com TABLE OF CONTENTS

More information

PAS 200MF 300 DATA SHEET

PAS 200MF 300 DATA SHEET PAS 2MF 3 DATA SHEET PAS 2MF 3 Diesel - Qmax 72 m³/h (3,17 USgpm) - Hmax 31 m (12 ft) PAS 2MF 3 Liquid cooled engine PAS 2MF 3 Air cooled engine Benefits PAS MF - Vacuum prime centrifugal pumps The pump

More information

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Filter module AF 43 Nominal pressure 16 bar, nominal temperature 180 C; nominal width DN 80 to DN

More information

TORK DIESEL FILTER/WATER SEPARATOR

TORK DIESEL FILTER/WATER SEPARATOR TORK DIESEL FILTER/WATER SEPARATOR www.smstork.com TECHNICAL SPECIFICATION MODELS T-WPS100 T-WPS230 T-WPS560 T-WPS1120 T-WPS1680 T-WPS2240 In-out Port Flow Rate LPH Horse Power Particle Seperation Dimensions

More information

10 mm free passage. Submersible drainage pumps US Application. Safe to run dry. Easy to maintain with guide rail system. 10 mm free passage

10 mm free passage. Submersible drainage pumps US Application. Safe to run dry. Easy to maintain with guide rail system. 10 mm free passage Submersible drainage pumps US 6-5 0 mm free passage Application The submersible drainage pumps US 6-5 can be used wherever sewage water with solids up to 0 mm particle size occurs, e.g. in collection sumps

More information

N Daily Weekly Monthly Every 3 months. Every 6 months 1 Remove any materials not related

N Daily Weekly Monthly Every 3 months. Every 6 months 1 Remove any materials not related MV / LV cabins maintenance The operation and maintenance of the cabins are meant to ensure high reliability (i.e. the early detection of anomalies, the failure prevention and monitoring functional) and

More information

MTF. Technical features

MTF. Technical features Technical features Power supply Three-phase voltage from 24V to 690V, 50Hz or 60Hz or 100-130V, 60Hz and 200-240V, 50Hz ( types are supplied without capacitor); suitable for use with an inverter from 20Hz

More information

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP KOBELCO KNW SERIES 1 OF 10 1. SPECIFICATIONS SCOPE 1.1 This specification covers the requirement for supply of a packaged oil-free rotary screw air compressor, Kobelco KNW Series model. 1.2 Any and all

More information

VacuClean Systematic Oil Treatment Patented

VacuClean Systematic Oil Treatment Patented Industrial Filters Accumulators VacuClean Systematic Oil Treatment Patented All-In-One system for cleaning and reconditioning of hydraulic oils and lubricants in the bypass flow Size Mobile: 20, 50, 80

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17 Genset with manual control panel. Image for guidance purposes. ENGINE ALTERNATOR MAKE KOHLER MAKE MODEL KDI3404TM MODEL CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) STAND-BY POWER: (LTP Limited

More information

QS441 CONE CRUSHER FEATURES & BENEFITS. Rev

QS441 CONE CRUSHER FEATURES & BENEFITS. Rev CONE CRUSHER FEATURES & BENEFITS Rev 1 23-12-14 Hopper Feeder Crusher Main conveyor Powerpack Controls Tracks Dimensions Options Benefits overview 2 HOPPER DOORS Heavy duty fixed hopper design enables

More information

PAS 100HF 250. Diesel - Qmax 280 m³/h (1,230 USgpm) - Hmax 50 m (164 ft) Benefits. PAS MF - Vacuum prime centrifugal pumps

PAS 100HF 250. Diesel - Qmax 280 m³/h (1,230 USgpm) - Hmax 50 m (164 ft) Benefits. PAS MF - Vacuum prime centrifugal pumps PAS 1HF 5 Diesel - Qmax 8 m³/h (1,3 USgpm) - Hmax 5 m (16 ft) PAS 1HF 5 Liquid cooled engine Benefits PAS MF - Vacuum prime centrifugal pumps The pump system consists of a centrifugal pump and a separator,

More information

Eclipse 2000 Service Parts

Eclipse 2000 Service Parts This part list contains the service parts for the Eclipse 000 systems. The models that are covered include: CME08 CP08 ERC08 Eclipse 000 Service Parts Table of Contents CME08 Cabinet Page CME08 Interior

More information

Grey Water and Condensate Pump. Rotex. Type Series Booklet

Grey Water and Condensate Pump. Rotex. Type Series Booklet Rotex Type Series Booklet Legal information/copyright Type Series Booklet Rotex Original operating manual All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,

More information

Quick Engineering Facts Decimal Metric

Quick Engineering Facts Decimal Metric Decimal Metric A. Decimal and Metric Equivalents Fraction (Inch) Decimal (Inch) mm Fraction (Inch) Decimal (Inch) mm 1/64 0.01562 0.397 33/64 0.51562 13.097 1/32 0.03125 0.794 17/32 0.53125 13.494 3/64

More information

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual. Chiller SWS/SWR 1602 to 4802 Water Cooled Chillers Only and Condenserless Versions Engineering Data Manual 272 to 1118 kw Specifications General The SWS water cooled screw chillers are equipped with high

More information

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS G115QX G115X ELECTRICAL FREQUENCY VOLTAGE PRIME STAND BY 50Hz 3ph 400/230v 107.7kVA / 86.2kW 118.5kVA / 94.8kW 60Hz 3Ph 380/220v 102.0kVA / 81.6kW 111.9kVA

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

CONTINUOUS CAPACITY CONTROL MODELS

CONTINUOUS CAPACITY CONTROL MODELS This series of air-cooled water chillers up to 400HP has been developed for various requirements of air conditioning systems and industrial chilled water systems, where these equipments are operated under

More information

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY AESV2S / AESU2S / AESV2S-LA (IE2) HIGH EFFICIENCY AESV3S / AESU3S / AESV3S-LA (IE3) PREMIUM

More information

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment Screw compressors CIAT shell and tubes direct expansion evaporator (High Power System) equipment Cooling capacity: 370 to 1 170 kw Heating capacity: 500 to 1 400 kw Heating Cooling Heat recovery Use The

More information

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL Design Standard Detailed specifications follow. PART 1 - GENERAL 1.01 SCOPE This design guidelines contained herein include the requirements of electric motors utilized for electric motor driven systems

More information

QH331 CONE CRUSHER FEATURES & BENEFITS. Rev Rev

QH331 CONE CRUSHER FEATURES & BENEFITS. Rev Rev CONE CRUSHER FEATURES & BENEFITS Rev 2 23-03-15 Rev 1 01-12-14 Hopper Feeder Crusher Main conveyor Powerpack Controls Tracks Dimensions Standard features Options Benefits overview 2 HOPPER DOORS Heavy

More information

SPECIFICATIONS DOUGLAS MODEL LD-20 POT, PAN, AND UTENSIL WASHER

SPECIFICATIONS DOUGLAS MODEL LD-20 POT, PAN, AND UTENSIL WASHER B05D PAN WASHER B05D PAN WASHER xxxxxx Effective: March 1, 2005 SPECIFICATIONS DOUGLAS MODEL LD-20 POT, PAN, AND UTENSIL WASHER CABINET 50 wide x 36 deep x 73 high Clearance Height: 100-3/4 (103-1/2 with

More information

Varian, Inc. Vacuum Technologies. Rotary Vane Pumps. Features and Benefits 2-3. Typical Applications 4-5. Pump Models 6-19.

Varian, Inc. Vacuum Technologies. Rotary Vane Pumps. Features and Benefits 2-3. Typical Applications 4-5. Pump Models 6-19. Varian, Inc. Vacuum Technologies Rotary Vane Pumps Features and Benefits 2-3 Typical Applications 4-5 Pump Models 6-19 Accessories 20 Frequency Inverter Technology 21 HS Series Pumps 22-25 MS40+ Features

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

FLUID TRANSFER SECTION 1

FLUID TRANSFER SECTION 1 SECTION 1 FLUID TRANSFER HF10 FILTRATION UNIT...2 SUPER DELUXE PORTABLE FILTRATION UNIT...2 VISCOMAT OIL TRANSFER PUMPS...3 DC PUMPS VISCOMAT DC...3 HAND OPERATED PUMPS FOR OIL DRUMS...4 CLEAN OIL TRANSFER

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

ELECTRIC SUBMERSIBLE PUMPS SEMISOM/80

ELECTRIC SUBMERSIBLE PUMPS SEMISOM/80 Electric pumps for professional applications to convey sewage water, entirely designed and manufactured in our Italian facility. APPLICATION PERFORMANCE RANGE To convey waste and sewage water from septic

More information

SIDE CHANNEL BLOWERS

SIDE CHANNEL BLOWERS SIDE CHANNEL BLOWERS RT-1 / RT-2 / RT-3 / RT-4 series 23 RT-4 / RT-5 / RT-6 / RT-7 / RT-8 / RT-9 series 24 RT-23 / RT-33 / RT-43 / RT-63 / RT-83 series 25 19 Applications Aeration Swiing pools and whirlpools

More information

KSI Filtertechnik GmbH Siemensring D Willich Tel Fax

KSI Filtertechnik GmbH Siemensring D Willich Tel Fax BA SIC.LINE Rev 1.0.1 Page 1 of 9 KSI Filtertechnik GmbH Siemensring 54-56 D-47877 Willich Tel. +49 21 54 89 108-0 Fax +49 21 54 89108-282 www.ksi.eu mail@ksi.eu ECOCLEAN Compressed air filters new generation

More information

Standby Power Systems

Standby Power Systems Source: Power Quality in Electrical Systems Chapter 13 Standby Power Systems The term standby power systems describes the equipment interposed between the utility power source and the electrical load to

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

Vessels and Distillation Equipment

Vessels and Distillation Equipment Vessels and Distillation Equipment 147 A suitable solution for practically every application in well-known BOLA-quality and optimally adapted to your needs. PRODUCT TIPS BOLA Scrubber Columns Pressure:

More information

Vacuum Pump. CapacityCapacity : M 3 /hr/hr Vacuumacuum : mmm ofof HgHg

Vacuum Pump. CapacityCapacity : M 3 /hr/hr Vacuumacuum : mmm ofof HgHg Single Stage Vacuum Pump CapacityCapacity : 800800. M 3 /hr/hr Vacuumacuum : 7070 mmm ofof HgHg SINGLE STAGE VACUUM PUMP Single Stage liquid-ring vacuum pumps are based on the Most Reliable SLM Maneklal

More information

ADU 5. Automatic Distillation Unit

ADU 5. Automatic Distillation Unit ADU 5 Automatic Distillation Unit Atmospheric Distillation Distillation tests are used to characterize the volatility of petrochemical products. These volatility characteristics are a critical measurement

More information

Integrated temperature test and calibration bench Model CBS-SC4000

Integrated temperature test and calibration bench Model CBS-SC4000 Calibration technology Integrated temperature test and calibration bench Model CBS-SC4000 WIKA data sheet CT 92.33 Applications Testing and calibration of temperature measuring instruments such as: - Mercury

More information

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes Comfort ventilation Very wide flow rate range : 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing APPLICATION ventilation are designed for the ventilation of tertiary or industrial buildings,

More information

CENTRIFUGAL CHILLER. Lubrication System Pull oil sample for spectroscopic analysis.

CENTRIFUGAL CHILLER. Lubrication System Pull oil sample for spectroscopic analysis. CENTRIFUGAL CHILLER Annual Inspection Refrigerant Circuit Check and record refrigerant level Inspect for leak results Calculate refrigerant lass and report to the customer. Repair minor leaks as required

More information

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP) PRAMAC GBW 45 Item code: SB450TPAY00 Main features Standby : 36 kw power LTP Rated prime : 34 kw power (PRP) Rated : kw continuous power (COP) Phases : 3 Voltage : 400 V Frequency : 50 Hz Engine : Perkins

More information

Automatic filter AF 113 G

Automatic filter AF 113 G Automatic filter AF 113 G Cast design with internal pressure cleaning and integrated cyclone effect Connection sizes: G2, screw in flange DN 50 and DN 65 1 Short description MAHLE automatic backflush filters

More information

Sample Specifications 2111_A00.doc 01/18/06 KOBELCO KNWA00 SERIES 1 of 8 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame HP

Sample Specifications 2111_A00.doc 01/18/06 KOBELCO KNWA00 SERIES 1 of 8 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame HP KOBELCO KNWA00 SERIES 1 of 8 1. SPECIFICATION SCOPE 1.1 This specification covers the requirement for supply of a packaged oil-free rotary screw air compressor, Kobelco KNW Series model. 1.2 Any and all

More information

We produce fluid power solutions. Fluid Management. Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements

We produce fluid power solutions. Fluid Management. Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements We produce fluid power solutions Fluid Management Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements Products with these icons are specially made for: Industrial

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22 TECHNICAL SPECIFICATIONS Model: IVRN-115 Image for guidance purposes. (400 / 230 V) ENGINE ALTERNATOR MAKE VOLVO MODEL MODEL TAD551GE (IIIA) MECC-ALTE ECP 34-2S / 4 CONTINUOUS POWER: (PRP Prime Power norma

More information

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR LAROX PERISTALTIC PUMPS FOR METERING The innovative Larox Peristaltic Pumps for Metering (LPP-M) set a new industry standard for peristaltic pump technology.

More information

H) OIL MIST FILTRATION

H) OIL MIST FILTRATION H) OIL MIST FILTRATION H Oil mist filtration H-1 Preface H-2 FMBHP/C oil mist bag mechanical filter and AZUR cartridges H-3 AZUR 3.0/5.0 EH oil m ist electrostatic filters 216/265 CE compliance H: Oil

More information