2.2.3 Mounting of climate sensors

Size: px
Start display at page:

Download "2.2.3 Mounting of climate sensors"

Transcription

1 Page Mounting of climate sensors The indoor temperature and humidity sensors should be placed: 1 m above the zone occupied by the animals, near the middle of the house. in draught-free zone, not in the heat jet and not where the heat comes last. where the sun does not shine directly on the sensor through a window. Remember to take into account that the altitude of the sun varies with the seasons/day. a plug on the humidity sensor is preferred, so it can be removed during cleaning. NB: Never use a plug on the temperature sensor, as a bad connection here might have disastrous results. The outdoor temperature sensor should be placed: on the shady side of the house to avoid the sun. as detached as possible, however protected from rain and snow. NB: As a protection against rodents and to ensure optimum durability, an armoured installation cable, minimum 1 mm 2, should always be used.

2 Page Electric Charts One of the three standard wiring diagrams , and is used dependent on whether it is without emergency opening, with MC 78M A ON/OFF emergency opening or MC 78T A temperature controlled emergency opening. In addition the wiring diagrams , and are used for the specific components Standard Wiring Diagram. Systems without Emergency Opening OUTDOOR SERVICE ROOM THE HOUSE DOL Standard Wiring Diagram. System with ON/OFF Emergency Opening OUTDOOR SERVICE ROOM THE HOUSE DOL 14 MC 78M A TEST

3 Page Standard Wiring Diagram. Systems with Temperature Controlled Emergency Opening OUTDOOR SERVICE ROOM THE HOUSE DOL 14 MC 78TM-1 A

4 Page Wiring Diagram. Winch Motors CL 74AV CL 74A ON/OFF CL 75A 24V min. 1,5 mm 2 CL 75A 230V min. 1,0 mm 2 CL 20 Belimo GM 24 + P1000 Belimo GM P1000 Belimo GM 24-SR CL 75A ON/OFF (Emergency Air Intake) CL 75A 24V (Emergency Air Intake) min. 1,5 mm 2 Pneumatisk (Emergency Air Intake)

5 Page Wiring Diagram. Fans, Heat, Cooling, 24-Hour Clock and Water Meter Max. 6,8A 2-core 3-core Max 6,8A MC 37 Max. 16A DOL23U Max. 3x10A Analog heating shunt ON/OFF Relay heat Cooling 24-hour clock Water clock

6 Page Wiring Diagram. MultiStep CL 74AV stepless 1 CL 74AV stepless 2 Winch motor 2 Winch motor 2B Step 1 Step 2 Step 3 Step 4 Step 5 Step 6

7 Page Electrical Installation The electrical installation deals with the setting of mains voltage, basic wiring diagrams, setting of the computer and wiring diagrams of each individual component. One of the 3 standard wiring diagrams is used, depending on whether it is without emergency opening, with MC 78M A ON/OFF emergency opening or MC 78T A temperature controlled emergency opening. The installation is made in following order: 1) Setting of mains voltage (2.3.1) 2) Connect cables as shown on one of the standard wiring diagrams ( , and ) 3) Connection of mains voltage (2.3.2) 4) Setting of the computer (2.3.3) 5) Connection of each individual component by means of the wiring diagrams in section (2.3.5) 6) Setting of the system (2.4) 7) Testing (2.5) Setting of Mains Voltage The mains voltage can be set at 220/230V or 240V. From the factory the setting is 220/230V. 240V is activated by moving a lead at the relay panel. The lead is right under the transformer. Supply voltage switch 220/ V Terminal block low current (2) Terminal block low current MAN/AUTO switch for fan MAN/AUTO switch for fan Terminal clock low current Terminal block heavy current Earth terminal and available loop terminals Terminal block heavy current (2) Figur Terminal blocks and settings of Figur Example of cable connection

8 Page Standard Wiring Diagram. Connection of Mains Voltage, Temperature Sensors and Alarm By insertion of 4 pcs. temperature sensors, the sensors must be connected two and two parallel in series with each other.

9 Page Standard Wiring Diagram. Connection of Mains Voltage, Temperature Sensors, Alarm and Emergency Opening TEST 1 terminal switch MC 78M A

10 ON/OFF DOL 2000 A TEST B TEST 12V 12V OK OK T15 T14 Page Standard Wiring Diagram. Connection of Mains Voltage, Temperature Sensors, Alarm, MC 78T A Temperature Controlled Emergency Opening MC 78T A -2 T16 T15 0V T14-2 T13 SYNC T12 0V P12 T11 LOG-2 P11 T10 P10 LOG-1 P9 T9 +BATT +RS2 P8 T8 P7 T7 +RS1 P6 T6 +24V T5 +24V + T4 +24V + + T3 +24V T2 +24V + _ T1 0V L2 12 TEST 1 terminal switch + _ N2 N3 N4 N5 N6 N7 N N L N /240V~ 10A NO NC L N1 N L1 _ 0-10V 0-10V V R27 R28 R29 R30 R31 T12 P12 0V P11 LOG-2 T11 T10 P10 LOG-1 T9 P9 +BATT T8 P8 +RS2 T7 P7 +RS1 +24V T6 P6 N L1 L2 (2) N _ T5 T4 T3 T2 T1 M L N _ X13-X20 X21-X O O C/ F O O C/ F O O C/ F (2) R20 R21 R21A R22 R23 R23A R24 R25 R26 L NO NC M 2 L N _ See MC 78T A manual fig. 4.8 R10 R10A R11 R12 R13 R14 R15 R16 R17 R18 R19 R8A R9 R8 R7 R6 R5 R4 R3 R2 R1

11 Page Connection of Mains Voltage Mains voltage is connected in order to set the computer, see section (2.3.3) Setting of the computer The chief part of the terminals are universal. Therefore different components can be connected to each individual terminal. When you have answered the questions of the computer in the intallation menu, it will show you where to connect the components. See section Menu survey installation. If you try to activate more than is possible, you will be notified at once., press. With and change to the right language., so to the left in the display is opposite Installation.. The display reads Humidity Sensor.. The display reads Yes With, choose between Yes and No.. The display reads Heat source.. The display reads 2 heat sources. With, choose between none, 1 heat source or 2 heat sources.. The display reads Heat source 1 [analog]. With, choose between analog and relay., The display reads Heat source 2 [relay]. With, choose between analog and relay.. The display reads Control: [synchronous heat]. With, choose between synchronous heat and separated heat. NB! Synchronous heat means that the two heat sources work parallel. Separated heat means first 100% from heat source 1 and then heat source 2.. The display reads Cooling/humidification/Soaking?.. The display reads Cooling? [Yes - internal]. With, choose between yes - internal, yes - external and no.

SE8300 Series Installation Guide 24 Vac Low Voltage

SE8300 Series Installation Guide 24 Vac Low Voltage Installation Guide 24 Vac Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 2 Configurable BI/UI Universal Inputs Overview 3 Setup Screen Display 3 Terminal Identification

More information

CM 5000D IN A HURRY?

CM 5000D IN A HURRY? CM 5000D Conventional and Tunnel Instructions IN A HURRY? Flip to Pages 6-13 for Wiring Diagrams 4-11. Investigate The REEL-FREE Winch Handle The REEL-FREE Winch Handle adds features to your curtain winching

More information

CRE, CRIE, CRNE CRKE, SPKE, MTRE, CHIE 1 & 3 phase

CRE, CRIE, CRNE CRKE, SPKE, MTRE, CHIE 1 & 3 phase GRUNDFOS INSTRUCTIONS CRE, CRIE, CRNE CRKE, SPKE, MTRE, CIE 1 & 3 phase Installation and operating instructions LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted

More information

Speed Dome 66 Installation Manual

Speed Dome 66 Installation Manual Speed Dome 66 Installation Manual Table of Contents 1 INSTALLATION... 6 1.1 Installation Preparation...6 1.2 Installation Mode...6 1.2.1 Speed Dome Installation Mode...6 1.2.2 Bracket Installation Mode...7

More information

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running

More information

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2 AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2 INTRODUCTION The Aquavar Intelligent Pump Controller from utilizes an all new Aquavar platform, and combines it with over 20 years of

More information

MC 785-SC. Operating Manual (Wall and panel mounting) Type: MANUAL Number of pages: 32 Version: V2.3

MC 785-SC. Operating Manual (Wall and panel mounting) Type: MANUAL Number of pages: 32 Version: V2.3 MC 785SC Operating Manual (Wall and panel mounting) Description : MC 785SC Step Control Doc.nr.: 2291 Type: MANUAL Number of pages: 32 Version: V2.3 File: Do2291 MC785SC v23 EN.wpd Software: MC785SC V2.11

More information

ECL Apex 10. User Guide. ECL Apex 10 *087R9745* Installation and configuration. *vijem102*

ECL Apex 10. User Guide. ECL Apex 10 *087R9745* Installation and configuration. *vijem102* User Guide ECL Apex 10 *087R9745* *vijem102* Installation and configuration VI.JE.M1.02 Danfoss 11/2004 DH-SMT VI.JE.M1.02 Danfoss 11/2004 DH-SMT ECL Apex 10 VI.JE.M1.02 Danfoss 11/2004 DH-SMT VI.JE.M1.02

More information

Long-Range Barrier Sensors

Long-Range Barrier Sensors Long-Range Barrier Sensors Manual Model # of Beams Length E-9626-2B190Q 2 pairs 26 (66cm) E-9643-4B190Q 4 pairs 43 (109cm) E-9661-6B190Q 6 pairs 61 (155cm) E-9679-8B190Q 8 pairs 79 (201cm) 4 Different

More information

/ LOSSNAY / LGH-RS2-E2

/ LOSSNAY / LGH-RS2-E2 2 Indoor units / / LGH-RS2-E2 unit CONTENTS LGH-RS2-E2. LGH-5RS2-E2 48 2. LGH-25RS2-E2 49. LGH-5RS2-E2 44 4. LGH-5RS2-E2 44 5. LGH-8RS2-E2 442 6. LGH-RS2-E2 7. LGH-5RS2-E2 8. LGH-2RS2-E2 44 444 445 9.

More information

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC This generator set has been designed to meet ISO 88 regulation. This generator set is available with CE certification. Enclosed product is tested according to EU noise legislation 000//EC Phase Ratings,

More information

VASCO. Variable Speed Controller ENGLISH

VASCO. Variable Speed Controller ENGLISH VASCO Variable Speed Controller ENGLISH Variable Speed Controller VASCO is a purpose-built family of variable frequency drives, designed to control and protect pumping systems based on changing pump speed.

More information

SE8300 Series Installation Guide 24 Vac Low Voltage

SE8300 Series Installation Guide 24 Vac Low Voltage SE00 Series Installation Guide Low Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation Terminal Identification & Function Terminal identification Wiring Typical Applications

More information

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V LMB- (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 5 in-lb for control of damper surfaces up to sq ft. Technical Data LMB- on/off-floating Power Supply VAC ±

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB-(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 80 in-lb for control of damper surfaces up to 5 sq ft. Application For on/off and floating point control of dampers

More information

1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION

1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION 1-3 MANUAL STARTERS EXERCISE OBJECTIVE Examine and describe the operation of manual motor starters. DISCUSSION Motor starters are made out of power switches and overload protection devices. They can be

More information

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC This generator set has been designed to meet ISO 8528 regulation. This generator set is available with CE certification. Enclosed product is tested according to EU noise legislation 2000/14/EC 3 Phase

More information

1. Product Information

1. Product Information AVS Control Panel 1. Product Information AVS is a pump control panel having 4.3 TFT touch screen, uniquely designed high efficient variable speed control and relay board. The touch control panel is located

More information

SE7200 Series Installation Guide

SE7200 Series Installation Guide SE7200 Series Installation Guide 24 VAC Low Voltage Zoning Terminal Equipment Controller For Commercial HVAC Applications CONTENTS Installation 2 Preparation 2 Location 2 Installation 2 Configurable BI/UI

More information

Modbus Integration Integration for Modbus Functionality for VT8600 Series

Modbus Integration Integration for Modbus Functionality for VT8600 Series Modbus Integration Integration for Modbus Functionality for VT8600 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS

More information

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit. CHAPTER 1 4 Electric Circuits SECTION Introduction to Electricity BEFORE YOU READ After you read this section, you should be able to answer these questions: What are the three main parts of a circuit?

More information

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology NMB (X) -MFT Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Torque min. 90 in-lb for control of damper surfaces up to sq ft. Technical Data NMB(X)-MFT Power Supply

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

WARNING. Trouble Shooting Bunk Lift Control Box For In-wall Slim Rack Systems. Content. Table of Contents:

WARNING. Trouble Shooting Bunk Lift Control Box For In-wall Slim Rack Systems. Content. Table of Contents: Trouble Shooting Bunk Lift Control Box 1510000199 For In-wall Slim Rack Systems Content Copyright Power Gear Issued: January 2013 #82-S0530, Rev. OA Read, understand and follow all instructions in Installation

More information

FD6209B LIABILITY DISCLAIMER

FD6209B LIABILITY DISCLAIMER VEHICLE CONFIGURATION SETTINGS CHART Use the chart below to navigate through the different settings the Setup touch button has to offer. Also use the chart to see the different configuration settings offered

More information

Green Inverters from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

Green Inverters from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters. Solar inverters for Asia Solar inverters for Europe Solar inverters for America Solar inverters for the Earth Green Inverters from GROWATT NEW ENERGY CO., LTD No. Building, Xicheng Industrial Zone Bao

More information

Warnings and Safety Tips

Warnings and Safety Tips Warnings and Safety Tips The following safety tips are essentially important. Please strictly follow the manual s instructions in operation to guarantee safety. Improper operation or incorrect working

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

PowerScale TECHNICAL SPECIFICATIONS

PowerScale TECHNICAL SPECIFICATIONS PowerScale TECHNICAL SPECIFICATIONS PowerScale highlights at a glance Best in class efficiency Cost savings during the entire life-cycle(tco) Low input harmonic distortion Cost saving during installation

More information

GRUNDFOS INSTRUCTIONS. Hydro MPC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Hydro MPC. Installation and operating instructions GRUNDFOS INSTRUCTIONS Hydro MPC Installation and operating instructions Declaration of Conformity We, Grundfos, declare under our sole responsibility that the products Hydro MPC, to which this declaration

More information

ConceptpowerTM Modular kVA

ConceptpowerTM Modular kVA TECHNICAL SPECIFICATIONS ConceptpowerTM Modular 10-15-20-30-40kVA Uninterruptible Supply (UPS) Modular, n+1 redundant, three-phase On-line, Double-Conversion, VFI Classic-Line 10-40kVA Gemini-Line 10-30kVA

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

MICROPROCESSOR BASED CONTROLLER

MICROPROCESSOR BASED CONTROLLER MICROPROCESSOR BASED CONTROLLER Electronic Controller for Bus HVAC Front Box Units FrontAIRE II SERVICE MANUAL TK 53337-3-MM (Rev. 0, 09/06) 2006 THERMO KING Table of contents 1. General Information...

More information

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00 This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle LX5 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.

More information

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00 This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

TECHNICAL HANDBOOK. for MULTISPLIT NETWORK SYSTEMS OR GROUP CONTROL

TECHNICAL HANDBOOK. for MULTISPLIT NETWORK SYSTEMS OR GROUP CONTROL TECHNICAL HANDBOOK for MULTISPLIT NETWORK SYSTEMS OR GROUP CONTROL DESCRIPTION * Compatible with IMPACT E, IMAGE E and IMAGE 600² E systems * Configurable as either group control or multisplit * Single

More information

DISCRETE INPUTS SUGGESTED LENGTH: 39 NOTE: YOUR UPS MAY NOT SUPPORT ALL FIELDS Description Address Offset Standard Address Value 0 Value 1 Alarm

DISCRETE INPUTS SUGGESTED LENGTH: 39 NOTE: YOUR UPS MAY NOT SUPPORT ALL FIELDS Description Address Offset Standard Address Value 0 Value 1 Alarm DISCRETE INPUTS SUGGESTED LENGTH: 39 NOTE: YOUR UPS MAY NOT SUPPORT ALL FIELDS Description Address Offset Standard Address Value 0 Value 1 Alarm Temperature 0x0100 0257 10257 OK Over Temperature Alarm

More information

SmartPak Welding Controller WK-MPS-16 Constant Current

SmartPak Welding Controller WK-MPS-16 Constant Current SmartPak Welding Controller WK-MPS-16 Constant Current Features Latest state of the art ATMEL 8 bit microprocessor technology Synchronous digital welding control allows absolute precision Up to16 programmers

More information

Warnings and Safety Tips

Warnings and Safety Tips Warnings and Safety Tips The following safety tips are essentially important. Please strictly follow the manual s instructions in operation to guarantee safety. Improper operation or incorrect working

More information

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V AMB4-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 80 in-lb for control of damper surfaces up to 45 sq ft. Application For on/off and floating point control of

More information

LK Control v.3 & LK Control v.3 - RA

LK Control v.3 & LK Control v.3 - RA LK Control v.3 & LK Control v.3 - RA Design LK Control v. 3 and LK Control v.3 -RA is complete unit for outdoor temperature-compensated heat regulation, adapted and pre-programmed for LK s Floor Heating

More information

Version 11 Controls for natural ventilation. NV Comfort Standard / Plus KNX control

Version 11 Controls for natural ventilation. NV Comfort Standard / Plus KNX control Version 11 Controls for natural ventilation NV Comfort Standard / Plus KNX control NV Comfort software card 230V 1.20 NV Comfort basis package Application central control of indoor climate with the potential

More information

3. Dimensions and weights Placement and installation Pressure lost Material... 14

3. Dimensions and weights Placement and installation Pressure lost Material... 14 These technical conditions define the scope of produced dimensions and versions of "ALUMINIUM REGULATION DAMPER RKALM ("damper"). These technical conditions apply to the manufacture, design, ordering,

More information

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA Honeywell CORE Drive SPECIFICATION DATA FEATURES APPLICATION The new Honeywell VFD CORE Drive addresses the need to save time for installation, and provides the lower total installed costs with years of

More information

Product Data Sheet 4184 N/17X. The engineer's choice

Product Data Sheet 4184 N/17X. The engineer's choice Product Data Sheet 4184 N/17X The engineer's choice 4184 N/17X INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical

More information

MC200CAB/4 Integral Version

MC200CAB/4 Integral Version Issue 2.2 Mar 2017 MC200CAB/4 Integral Version Industrial & Commercial Heating Systems. www.powrmatic.co.uk Setting Instructions WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Reset from Lockout is

More information

Soliswitch FTE30. Technical Information

Soliswitch FTE30. Technical Information Technical Information Soliswitch FTE30 Level limit switch Economical paddle limit switch with type-examination certificate to ATEX dust Ex-approval zone 20 Application The universal paddle level limit

More information

CH-158 Color Bank 8 USER MANUAL

CH-158 Color Bank 8 USER MANUAL CH-158 Color Bank 8 USER MANUAL CHAUVET, 3000 N 29 th Ct, Hollywood, FL 33020 U.S.A (800) 762-1084 (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.com TABLE OF CONTENT BEFORE YOU BEGIN... 3 WHAT

More information

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

SolarMax S series (Australia) Maximising solar plant yields can be so easy. SolarMax S series (Australia) Maximising solar plant yields can be so easy. The convincing solution. We have been developing and producing transformerless inverters for over 20 years. Our engineers have

More information

APD 1650 M. Generator expert, honest advice with competitive solutions kva Diesel Generating Sets

APD 1650 M. Generator expert, honest advice with competitive solutions kva Diesel Generating Sets Generator expert, Engine : 1650 kva Control System : Standby P 732 control system This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified

More information

From domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs.

From domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs. PRODUCT RANGE PRODUCT Contents RANGE Wall Hung Split Systems Variable Capacity Pages 4- Split Ducted Standard Cycling Pages 6-11 The ActronAir range of air conditioners provides a solution for most applications.

More information

OPERATING INSTRUCTIONS ECON-M

OPERATING INSTRUCTIONS ECON-M OPERATING INSTRUCTIONS ECON-M INDEX 1.0 Introduction 2.0 Salient features, Protection & Supervision 3.0 Display/ Front Panel 4.0 Switches Description 5.0 LED Annunciations Description 6.0 Lamp Test 7.0

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey

More information

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller LC-ZEC200-xxxx Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller Description The CCS Variable Air Volume (VAV) Zone Pressure Independent Damper Controllers

More information

Paralleling Equipment

Paralleling Equipment Paralleling Equipment PowerCommand Model 300 Digital Master Control Description The PowerCommand TM Digital MasterControl is a microprocessor-based paralleling system component, designed to directly interface

More information

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life! Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 550KVA Generator Set Specification. Ultra Silent, Extended Life! Page - 1 - of 5 3-Phase, 50Hz@1500RPM

More information

3KW Off-grid Solar Power System LFP Battery

3KW Off-grid Solar Power System LFP Battery 3KW Off-grid Solar Power System LFP Battery 1 CATALOGUE 1. S u m m a r y 3 2. T e c h n i c a l p a r a m e t e r 4 3. D i s p l a y a n d f u n c t i o n i n s t r u c t i o n 5 4. S e q u e n c e o f

More information

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB Catalogue Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv 97-1 96-1054 Medium Voltage 1 Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Index Description...

More information

CLASSIC MPPT CHARGE CONTROLLERS

CLASSIC MPPT CHARGE CONTROLLERS CLASSIC MPPT CHARGE CONTROLLERS The worlds most sophisticated MPPT charge controller BAR NONE!!! THE CLASSICS The Classic line of MPPT charge controllers are one of the most powerful in the RE industry.

More information

Power Solution Supplier

Power Solution Supplier Power Solution Supplier. Diesel & Gas Power Generators. Power Plant. Transformer Substation. CHP & CCHP System Guangdong Honny Power-Tech Co., Ltd GENERATOR FEATURE Engine and alternator shall be mounted

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER UHC 300 22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER OVERVIEW The HVAC building automation controls market requires a DDC controller that provides scalable, consolidated control in a fully programmable,

More information

User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A

User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A Copyright 2005 AMETEK DENMARK A/S (123199-UK)

More information

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle LX10 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 3000 N 29 th Ct, Hollywood, FL 33020 U.S.A.

More information

Mounting Installation Instructions LM, NM, AM, GM

Mounting Installation Instructions LM, NM, AM, GM 709-0000 Rev G Mounting Installation Instructions LM, NM, AM, GM General Information Preliminary steps. Belimo actuators with NEMA or NEMA ratings should be mounted indoors in a dry, relatively clean environment

More information

DA/CL 74C Gear Motor and PCB

DA/CL 74C Gear Motor and PCB /L 74 Gear Motor and P Technical User Guide English: For other language variants of this document we refer to: Español: Para otras variantes del idioma de este documento, visite: Français: Pour les versions

More information

WARNING. Trouble Shooting Slide Out Control Box For In-wall Slim Rack Systems. Content. Table of Contents:

WARNING. Trouble Shooting Slide Out Control Box For In-wall Slim Rack Systems. Content. Table of Contents: Trouble Shooting Slide Out Control Box 1510000199 For In-wall Slim Rack Systems Content Copyright Power Gear Issued: January 2013 #82-S0518, Rev. OA Read, understand and follow all instructions in Installation

More information

Graf Aqua Controller Programming & Setup to use with 3- way valve for backup systems

Graf Aqua Controller Programming & Setup to use with 3- way valve for backup systems Graf Aqua Controller Programming & Setup to use with 3- way valve for backup systems Back-up System Overview The Graf Aqua Control and Three way valve combined will automate the operation of a backup water

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

User Instructions for WRC1021D. Doc

User Instructions for WRC1021D. Doc User Instructions for WRC1021D Doc. 0001-5989 CONTENTS 1.0 INTRODUCTION TO THE WRC1021D... 2 2.0 FUNCTIONAL DESCRIPTION... 3 3.0 POTENTIOMETERS, SWITCHES AND INDICATORS... 5 4.0 CALIBRATION AND START-UP

More information

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual DC AC POWER INVERTER LIV 10 / LIV 20 / LIV 30 User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the Power Inverter. This

More information

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9 ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 9 (RTU1) CESMPU025REVAV9 Date: December 1, 2014 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV9 Unit features include: 25 ton MultiPath

More information

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS.

SERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS. SPLIT-TYPE, AIR CONDITIONERS Revision A: MU-A2YV - E can be connected to MCF-A2WV - E. Please void OB330. SERVICE MANUAL Wireless type Models E MU-A07YV - E MU-A09YV - MU-A2YV - E HFC utilized R40A No.

More information

Proximity Sensors. Reference Information. Principles of Operation. Proximity Sensors

Proximity Sensors. Reference Information. Principles of Operation. Proximity Sensors Reference Proximity Sensors Principles of Operation Inductive Proximity sensors are generally constructed with four main elements: (1) a coil and ferrite core assembly; (2) an oscillator; (3) a convertor/trigger

More information

Customer Training Catalog Training Proposal. Training Description for Network Energy COMMERCIAL IN CONFIDENCE 1

Customer Training Catalog Training Proposal. Training Description for Network Energy COMMERCIAL IN CONFIDENCE 1 Customer Catalog Proposal Description for Network Energy COMMERCIAL IN CONFIDENCE 1 Customer Catalog Proposal CONTENTS 1 Path... 3 1.1 Power Supply Path... 4 1.2 Data Center Facility Path... 5 1.3 UPS

More information

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS MAKING MODERN LIVING POSSIBLE UniLynx Indoor Installation Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 Installation Sequence 2 Important

More information

PART NO CP-DOOR FRONT PANEL WINDOW PART NO CP-DOOR FRONT PANEL SECOND WINDOW PART NO CP-DOOR LOCK PART NO. 5026

PART NO CP-DOOR FRONT PANEL WINDOW PART NO CP-DOOR FRONT PANEL SECOND WINDOW PART NO CP-DOOR LOCK PART NO. 5026 5010 CP-DOOR FRONT PANEL WINDOW 5015 CP-DOOR FRONT PANEL SECOND WINDOW 5025 CP-DOOR LOCK 5026 CP-DOOR LOCKING CYLINDER 5027 CP MOUNTING BRACKET (PACKET OF 4) 5030 OBSOLETE CP-DOOR PUSH-BUTTON GREEN (HEAD

More information

Three Phase UPS Systems Range: 10 to 500kVA

Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying

More information

Description. functions including single duct pressure dependent or pressure independent systems.

Description. functions including single duct pressure dependent or pressure independent systems. Description The Meridian Basic control system converts a single zone HVAC unit into a variable air volume/variable air temperature multiple zone system. The microprocessor based Zone Manager calculates

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

Combined Ventilation Controller RVWS-T-224HA

Combined Ventilation Controller RVWS-T-224HA Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage

More information

PowerScale kva Technical Specifications

PowerScale kva Technical Specifications PowerScale 10-50 kva Technical Specifications Copyright 2015 ABB, All rights reserved. TABLE OF CONTENTS 10.1 POWERSCALE SYSTEM DESCRIPTION... 3 10.2 TECHNICAL CHARACTERISTICS... 4 10.2.1 MECHANICAL CHARACTERISTICS

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

DX330 L/M/V. Safer. Faster. Easier SERIES DOTECH, INC. Universal Intelligent Controller for Screw Air Compressor

DX330 L/M/V. Safer. Faster. Easier SERIES DOTECH, INC. Universal Intelligent Controller for Screw Air Compressor DX330 L/M/V SERIES Universal Intelligent Controller for Screw Air Compressor Please experience DOTECH s technology based on simplicity, multi-function and safety!! Easier Faster Safer DOTECH, INC http://www.dotech21.com

More information

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS NB 0811 - NB 1511 NB 0831 - NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS LEN.MAN.UPS.069 Rev.2.00/2002 CONTENTS Safety Instructions 1 Introduction 3 2.1 FEATURE 3 2.2 UPS modules 4 How the UPS works 5 3.1

More information

Installation Motor driven valve

Installation Motor driven valve Installation Motor driven valve Before the system may be taken into use, this manual must be studied carefully. Only, by MEDICVENT, authorized personnel are allowed to perform adjustments or repairs on

More information

Mobile Access, TimeTec Smart Tripod Turnstile TTS 2200B Installation Manual

Mobile Access, TimeTec Smart Tripod Turnstile TTS 2200B Installation Manual www.timeteccloud.com Mobile Access, TimeTec Smart Tripod Turnstile TTS 2200B Installation Manual TS2200: Tripod Turnstile TS2211: Tripod Turnstile with Controller and RFID Reader TS2222: Tripod Turnstile

More information

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed

More information

GRUNDFOS INSTRUCTIONS. Control HVAC. Installation and operating instructions. Other languages. net.grundfos.com/qr/i/

GRUNDFOS INSTRUCTIONS. Control HVAC. Installation and operating instructions. Other languages. net.grundfos.com/qr/i/ GRUNDFOS INSTRUCTIONS Control HVAC Installation and operating instructions Other languages net.grundfos.com/qr/i/98800750 English (GB) English (GB) Installation and operating instructions Original installation

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

OBS-LE Series LED Digital Pressure Gauge. Operating Manual. Bar MPa KPa/KG. Psi

OBS-LE Series LED Digital Pressure Gauge. Operating Manual. Bar MPa KPa/KG. Psi LED Digital ure Gauge / Transmitter / Switch OBS-LE Series LED Digital ure Gauge Operating Manual LED Alarms Bright LED Display Lock key / Shift Digits Engineering ure Units BAR MPr KPa/KG Programming

More information

CRE, CRIE, CRNE CRKE, SPKE, MTRE, CHIE, CME

CRE, CRIE, CRNE CRKE, SPKE, MTRE, CHIE, CME GRUNDFOS INSTRUCTIONS CRE, CRIE, CRNE CRKE, SPKE, MTRE, CHIE, CME 1 & 3 phase Installation and operating instructions 2 English (US) Installation and operating instructions Original installation and operating

More information

STRA-24 for chilled beams

STRA-24 for chilled beams STRA- Installation and commissioning manual STRA- for chilled beams STRA- is the room controller for the pressure independent (Pi) and constant air volume chilled beams. It is possible to set different

More information

Ørstedsvej Silkeborg DENMARK

Ørstedsvej Silkeborg DENMARK Ørstedsvej 4 8600 Silkeborg DENMARK Tel +45 86 80 58 66 Fax +45 86 80 58 67 E-mail mail@pronamic.com http:/www.pronamic.com Before connecting, operating or adjusting this product, please read these instructions

More information

AIS 5000 UPS kva 480 V. Installation Manual

AIS 5000 UPS kva 480 V. Installation Manual AIS 5000 UPS 10-100 kva 480 V Installation Manual IMPORTANT! THIS DOCUMENT CONTAINS IMPORTANT SAFETY INSTRUCTIONS - PLEASE SAVE THESE INSTRUCTIONS! Contents Safety...1 IMPORTANT SAFETY INSTRUCTIONS - SAVE

More information

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life! Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 660KVA Generator Set Specification NO: GKP660KVA2012 c 2012 The Generator King (Pty) Ltd. Ultra Silent,

More information

MANIFOLDS & WATER TEMPERATURE CONTROL

MANIFOLDS & WATER TEMPERATURE CONTROL MANIFOLDS & WATER TEMPERATURE CONTROL Overview Water based underfloor heating (UFH) systems work by turning the entire floor into one large low temperature radiator which is heated via a network of pipes

More information

Shenzhen Sine Electric Co., Ltd.

Shenzhen Sine Electric Co., Ltd. Page 1 of 5 Favorite Contact 中文 Please enter key words 提交查 Home Products Solutions Service About us Products EM500 Open loop Inverter Your current location:home > Products Standard Inverters EM500 Open

More information

Speed-Pro EFI Installation Manual

Speed-Pro EFI Installation Manual Speed-Pro EFI Installation Manual Speed-Pro Electronics Installation Manual Page The wiring harness is labeled on each of the connectors to simplify installation. Your application may not require the use

More information