1 Page Mounting of climate sensors The indoor temperature and humidity sensors should be placed: 1 m above the zone occupied by the animals, near the middle of the house. in draught-free zone, not in the heat jet and not where the heat comes last. where the sun does not shine directly on the sensor through a window. Remember to take into account that the altitude of the sun varies with the seasons/day. a plug on the humidity sensor is preferred, so it can be removed during cleaning. NB: Never use a plug on the temperature sensor, as a bad connection here might have disastrous results. The outdoor temperature sensor should be placed: on the shady side of the house to avoid the sun. as detached as possible, however protected from rain and snow. NB: As a protection against rodents and to ensure optimum durability, an armoured installation cable, minimum 1 mm 2, should always be used.
2 Page Electric Charts One of the three standard wiring diagrams , and is used dependent on whether it is without emergency opening, with MC 78M A ON/OFF emergency opening or MC 78T A temperature controlled emergency opening. In addition the wiring diagrams , and are used for the specific components Standard Wiring Diagram. Systems without Emergency Opening OUTDOOR SERVICE ROOM THE HOUSE DOL Standard Wiring Diagram. System with ON/OFF Emergency Opening OUTDOOR SERVICE ROOM THE HOUSE DOL 14 MC 78M A TEST
3 Page Standard Wiring Diagram. Systems with Temperature Controlled Emergency Opening OUTDOOR SERVICE ROOM THE HOUSE DOL 14 MC 78TM-1 A
4 Page Wiring Diagram. Winch Motors CL 74AV CL 74A ON/OFF CL 75A 24V min. 1,5 mm 2 CL 75A 230V min. 1,0 mm 2 CL 20 Belimo GM 24 + P1000 Belimo GM P1000 Belimo GM 24-SR CL 75A ON/OFF (Emergency Air Intake) CL 75A 24V (Emergency Air Intake) min. 1,5 mm 2 Pneumatisk (Emergency Air Intake)
5 Page Wiring Diagram. Fans, Heat, Cooling, 24-Hour Clock and Water Meter Max. 6,8A 2-core 3-core Max 6,8A MC 37 Max. 16A DOL23U Max. 3x10A Analog heating shunt ON/OFF Relay heat Cooling 24-hour clock Water clock
6 Page Wiring Diagram. MultiStep CL 74AV stepless 1 CL 74AV stepless 2 Winch motor 2 Winch motor 2B Step 1 Step 2 Step 3 Step 4 Step 5 Step 6
7 Page Electrical Installation The electrical installation deals with the setting of mains voltage, basic wiring diagrams, setting of the computer and wiring diagrams of each individual component. One of the 3 standard wiring diagrams is used, depending on whether it is without emergency opening, with MC 78M A ON/OFF emergency opening or MC 78T A temperature controlled emergency opening. The installation is made in following order: 1) Setting of mains voltage (2.3.1) 2) Connect cables as shown on one of the standard wiring diagrams ( , and ) 3) Connection of mains voltage (2.3.2) 4) Setting of the computer (2.3.3) 5) Connection of each individual component by means of the wiring diagrams in section (2.3.5) 6) Setting of the system (2.4) 7) Testing (2.5) Setting of Mains Voltage The mains voltage can be set at 220/230V or 240V. From the factory the setting is 220/230V. 240V is activated by moving a lead at the relay panel. The lead is right under the transformer. Supply voltage switch 220/ V Terminal block low current (2) Terminal block low current MAN/AUTO switch for fan MAN/AUTO switch for fan Terminal clock low current Terminal block heavy current Earth terminal and available loop terminals Terminal block heavy current (2) Figur Terminal blocks and settings of Figur Example of cable connection
8 Page Standard Wiring Diagram. Connection of Mains Voltage, Temperature Sensors and Alarm By insertion of 4 pcs. temperature sensors, the sensors must be connected two and two parallel in series with each other.
9 Page Standard Wiring Diagram. Connection of Mains Voltage, Temperature Sensors, Alarm and Emergency Opening TEST 1 terminal switch MC 78M A
10 ON/OFF DOL 2000 A TEST B TEST 12V 12V OK OK T15 T14 Page Standard Wiring Diagram. Connection of Mains Voltage, Temperature Sensors, Alarm, MC 78T A Temperature Controlled Emergency Opening MC 78T A -2 T16 T15 0V T14-2 T13 SYNC T12 0V P12 T11 LOG-2 P11 T10 P10 LOG-1 P9 T9 +BATT +RS2 P8 T8 P7 T7 +RS1 P6 T6 +24V T5 +24V + T4 +24V + + T3 +24V T2 +24V + _ T1 0V L2 12 TEST 1 terminal switch + _ N2 N3 N4 N5 N6 N7 N N L N /240V~ 10A NO NC L N1 N L1 _ 0-10V 0-10V V R27 R28 R29 R30 R31 T12 P12 0V P11 LOG-2 T11 T10 P10 LOG-1 T9 P9 +BATT T8 P8 +RS2 T7 P7 +RS1 +24V T6 P6 N L1 L2 (2) N _ T5 T4 T3 T2 T1 M L N _ X13-X20 X21-X O O C/ F O O C/ F O O C/ F (2) R20 R21 R21A R22 R23 R23A R24 R25 R26 L NO NC M 2 L N _ See MC 78T A manual fig. 4.8 R10 R10A R11 R12 R13 R14 R15 R16 R17 R18 R19 R8A R9 R8 R7 R6 R5 R4 R3 R2 R1
11 Page Connection of Mains Voltage Mains voltage is connected in order to set the computer, see section (2.3.3) Setting of the computer The chief part of the terminals are universal. Therefore different components can be connected to each individual terminal. When you have answered the questions of the computer in the intallation menu, it will show you where to connect the components. See section Menu survey installation. If you try to activate more than is possible, you will be notified at once., press. With and change to the right language., so to the left in the display is opposite Installation.. The display reads Humidity Sensor.. The display reads Yes With, choose between Yes and No.. The display reads Heat source.. The display reads 2 heat sources. With, choose between none, 1 heat source or 2 heat sources.. The display reads Heat source 1 [analog]. With, choose between analog and relay., The display reads Heat source 2 [relay]. With, choose between analog and relay.. The display reads Control: [synchronous heat]. With, choose between synchronous heat and separated heat. NB! Synchronous heat means that the two heat sources work parallel. Separated heat means first 100% from heat source 1 and then heat source 2.. The display reads Cooling/humidification/Soaking?.. The display reads Cooling? [Yes - internal]. With, choose between yes - internal, yes - external and no.
SE8300 Series Installation Guide 24 Vac Low Voltage
Installation Guide 24 Vac Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 2 Configurable BI/UI Universal Inputs Overview 3 Setup Screen Display 3 Terminal Identification
More informationCM 5000D IN A HURRY?
CM 5000D Conventional and Tunnel Instructions IN A HURRY? Flip to Pages 6-13 for Wiring Diagrams 4-11. Investigate The REEL-FREE Winch Handle The REEL-FREE Winch Handle adds features to your curtain winching
More informationCRE, CRIE, CRNE CRKE, SPKE, MTRE, CHIE 1 & 3 phase
GRUNDFOS INSTRUCTIONS CRE, CRIE, CRNE CRKE, SPKE, MTRE, CIE 1 & 3 phase Installation and operating instructions LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted
More informationSpeed Dome 66 Installation Manual
Speed Dome 66 Installation Manual Table of Contents 1 INSTALLATION... 6 1.1 Installation Preparation...6 1.2 Installation Mode...6 1.2.1 Speed Dome Installation Mode...6 1.2.2 Bracket Installation Mode...7
More informationPOWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting
POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running
More informationAQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2
AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2 INTRODUCTION The Aquavar Intelligent Pump Controller from utilizes an all new Aquavar platform, and combines it with over 20 years of
More informationMC 785-SC. Operating Manual (Wall and panel mounting) Type: MANUAL Number of pages: 32 Version: V2.3
MC 785SC Operating Manual (Wall and panel mounting) Description : MC 785SC Step Control Doc.nr.: 2291 Type: MANUAL Number of pages: 32 Version: V2.3 File: Do2291 MC785SC v23 EN.wpd Software: MC785SC V2.11
More informationECL Apex 10. User Guide. ECL Apex 10 *087R9745* Installation and configuration. *vijem102*
User Guide ECL Apex 10 *087R9745* *vijem102* Installation and configuration VI.JE.M1.02 Danfoss 11/2004 DH-SMT VI.JE.M1.02 Danfoss 11/2004 DH-SMT ECL Apex 10 VI.JE.M1.02 Danfoss 11/2004 DH-SMT VI.JE.M1.02
More informationLong-Range Barrier Sensors
Long-Range Barrier Sensors Manual Model # of Beams Length E-9626-2B190Q 2 pairs 26 (66cm) E-9643-4B190Q 4 pairs 43 (109cm) E-9661-6B190Q 6 pairs 61 (155cm) E-9679-8B190Q 8 pairs 79 (201cm) 4 Different
More information/ LOSSNAY / LGH-RS2-E2
2 Indoor units / / LGH-RS2-E2 unit CONTENTS LGH-RS2-E2. LGH-5RS2-E2 48 2. LGH-25RS2-E2 49. LGH-5RS2-E2 44 4. LGH-5RS2-E2 44 5. LGH-8RS2-E2 442 6. LGH-RS2-E2 7. LGH-5RS2-E2 8. LGH-2RS2-E2 44 444 445 9.
More informationThis generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC
This generator set has been designed to meet ISO 88 regulation. This generator set is available with CE certification. Enclosed product is tested according to EU noise legislation 000//EC Phase Ratings,
More informationVASCO. Variable Speed Controller ENGLISH
VASCO Variable Speed Controller ENGLISH Variable Speed Controller VASCO is a purpose-built family of variable frequency drives, designed to control and protect pumping systems based on changing pump speed.
More informationSE8300 Series Installation Guide 24 Vac Low Voltage
SE00 Series Installation Guide Low Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation Terminal Identification & Function Terminal identification Wiring Typical Applications
More informationLMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
LMB- (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 5 in-lb for control of damper surfaces up to sq ft. Technical Data LMB- on/off-floating Power Supply VAC ±
More informationAMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
AMB-(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, V Torque min. 80 in-lb for control of damper surfaces up to 5 sq ft. Application For on/off and floating point control of dampers
More information1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION
1-3 MANUAL STARTERS EXERCISE OBJECTIVE Examine and describe the operation of manual motor starters. DISCUSSION Motor starters are made out of power switches and overload protection devices. They can be
More informationThis generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC
This generator set has been designed to meet ISO 8528 regulation. This generator set is available with CE certification. Enclosed product is tested according to EU noise legislation 2000/14/EC 3 Phase
More information1. Product Information
AVS Control Panel 1. Product Information AVS is a pump control panel having 4.3 TFT touch screen, uniquely designed high efficient variable speed control and relay board. The touch control panel is located
More informationSE7200 Series Installation Guide
SE7200 Series Installation Guide 24 VAC Low Voltage Zoning Terminal Equipment Controller For Commercial HVAC Applications CONTENTS Installation 2 Preparation 2 Location 2 Installation 2 Configurable BI/UI
More informationModbus Integration Integration for Modbus Functionality for VT8600 Series
Modbus Integration Integration for Modbus Functionality for VT8600 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS
More information4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.
CHAPTER 1 4 Electric Circuits SECTION Introduction to Electricity BEFORE YOU READ After you read this section, you should be able to answer these questions: What are the three main parts of a circuit?
More informationNMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology
NMB (X) -MFT Proportional Control, Non-Spring Return, Direct Coupled, V, Multi-Function Technology Torque min. 90 in-lb for control of damper surfaces up to sq ft. Technical Data NMB(X)-MFT Power Supply
More informationOn Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual
On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains
More informationWARNING. Trouble Shooting Bunk Lift Control Box For In-wall Slim Rack Systems. Content. Table of Contents:
Trouble Shooting Bunk Lift Control Box 1510000199 For In-wall Slim Rack Systems Content Copyright Power Gear Issued: January 2013 #82-S0530, Rev. OA Read, understand and follow all instructions in Installation
More informationFD6209B LIABILITY DISCLAIMER
VEHICLE CONFIGURATION SETTINGS CHART Use the chart below to navigate through the different settings the Setup touch button has to offer. Also use the chart to see the different configuration settings offered
More informationGreen Inverters from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.
Solar inverters for Asia Solar inverters for Europe Solar inverters for America Solar inverters for the Earth Green Inverters from GROWATT NEW ENERGY CO., LTD No. Building, Xicheng Industrial Zone Bao
More informationWarnings and Safety Tips
Warnings and Safety Tips The following safety tips are essentially important. Please strictly follow the manual s instructions in operation to guarantee safety. Improper operation or incorrect working
More informationThis generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
More informationPowerScale TECHNICAL SPECIFICATIONS
PowerScale TECHNICAL SPECIFICATIONS PowerScale highlights at a glance Best in class efficiency Cost savings during the entire life-cycle(tco) Low input harmonic distortion Cost saving during installation
More informationGRUNDFOS INSTRUCTIONS. Hydro MPC. Installation and operating instructions
GRUNDFOS INSTRUCTIONS Hydro MPC Installation and operating instructions Declaration of Conformity We, Grundfos, declare under our sole responsibility that the products Hydro MPC, to which this declaration
More informationConceptpowerTM Modular kVA
TECHNICAL SPECIFICATIONS ConceptpowerTM Modular 10-15-20-30-40kVA Uninterruptible Supply (UPS) Modular, n+1 redundant, three-phase On-line, Double-Conversion, VFI Classic-Line 10-40kVA Gemini-Line 10-30kVA
More informationThis generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
More informationMICROPROCESSOR BASED CONTROLLER
MICROPROCESSOR BASED CONTROLLER Electronic Controller for Bus HVAC Front Box Units FrontAIRE II SERVICE MANUAL TK 53337-3-MM (Rev. 0, 09/06) 2006 THERMO KING Table of contents 1. General Information...
More informationEnclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00
This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed
More informationSnapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle
LX5 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.
More informationEnclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00
This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed
More informationTECHNICAL HANDBOOK. for MULTISPLIT NETWORK SYSTEMS OR GROUP CONTROL
TECHNICAL HANDBOOK for MULTISPLIT NETWORK SYSTEMS OR GROUP CONTROL DESCRIPTION * Compatible with IMPACT E, IMAGE E and IMAGE 600² E systems * Configurable as either group control or multisplit * Single
More informationDISCRETE INPUTS SUGGESTED LENGTH: 39 NOTE: YOUR UPS MAY NOT SUPPORT ALL FIELDS Description Address Offset Standard Address Value 0 Value 1 Alarm
DISCRETE INPUTS SUGGESTED LENGTH: 39 NOTE: YOUR UPS MAY NOT SUPPORT ALL FIELDS Description Address Offset Standard Address Value 0 Value 1 Alarm Temperature 0x0100 0257 10257 OK Over Temperature Alarm
More informationSmartPak Welding Controller WK-MPS-16 Constant Current
SmartPak Welding Controller WK-MPS-16 Constant Current Features Latest state of the art ATMEL 8 bit microprocessor technology Synchronous digital welding control allows absolute precision Up to16 programmers
More informationWarnings and Safety Tips
Warnings and Safety Tips The following safety tips are essentially important. Please strictly follow the manual s instructions in operation to guarantee safety. Improper operation or incorrect working
More informationAMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V
AMB4-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 4 V Torque min. 80 in-lb for control of damper surfaces up to 45 sq ft. Application For on/off and floating point control of
More informationLK Control v.3 & LK Control v.3 - RA
LK Control v.3 & LK Control v.3 - RA Design LK Control v. 3 and LK Control v.3 -RA is complete unit for outdoor temperature-compensated heat regulation, adapted and pre-programmed for LK s Floor Heating
More informationVersion 11 Controls for natural ventilation. NV Comfort Standard / Plus KNX control
Version 11 Controls for natural ventilation NV Comfort Standard / Plus KNX control NV Comfort software card 230V 1.20 NV Comfort basis package Application central control of indoor climate with the potential
More information3. Dimensions and weights Placement and installation Pressure lost Material... 14
These technical conditions define the scope of produced dimensions and versions of "ALUMINIUM REGULATION DAMPER RKALM ("damper"). These technical conditions apply to the manufacture, design, ordering,
More informationHoneywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA
Honeywell CORE Drive SPECIFICATION DATA FEATURES APPLICATION The new Honeywell VFD CORE Drive addresses the need to save time for installation, and provides the lower total installed costs with years of
More informationProduct Data Sheet 4184 N/17X. The engineer's choice
Product Data Sheet 4184 N/17X The engineer's choice 4184 N/17X INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical
More informationMC200CAB/4 Integral Version
Issue 2.2 Mar 2017 MC200CAB/4 Integral Version Industrial & Commercial Heating Systems. www.powrmatic.co.uk Setting Instructions WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Reset from Lockout is
More informationSoliswitch FTE30. Technical Information
Technical Information Soliswitch FTE30 Level limit switch Economical paddle limit switch with type-examination certificate to ATEX dust Ex-approval zone 20 Application The universal paddle level limit
More informationCH-158 Color Bank 8 USER MANUAL
CH-158 Color Bank 8 USER MANUAL CHAUVET, 3000 N 29 th Ct, Hollywood, FL 33020 U.S.A (800) 762-1084 (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.com TABLE OF CONTENT BEFORE YOU BEGIN... 3 WHAT
More informationSolarMax S series (Australia) Maximising solar plant yields can be so easy.
SolarMax S series (Australia) Maximising solar plant yields can be so easy. The convincing solution. We have been developing and producing transformerless inverters for over 20 years. Our engineers have
More informationAPD 1650 M. Generator expert, honest advice with competitive solutions kva Diesel Generating Sets
Generator expert, Engine : 1650 kva Control System : Standby P 732 control system This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified
More informationFrom domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs.
PRODUCT RANGE PRODUCT Contents RANGE Wall Hung Split Systems Variable Capacity Pages 4- Split Ducted Standard Cycling Pages 6-11 The ActronAir range of air conditioners provides a solution for most applications.
More informationOPERATING INSTRUCTIONS ECON-M
OPERATING INSTRUCTIONS ECON-M INDEX 1.0 Introduction 2.0 Salient features, Protection & Supervision 3.0 Display/ Front Panel 4.0 Switches Description 5.0 LED Annunciations Description 6.0 Lamp Test 7.0
More informationCENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue
CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey
More informationCommerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller
LC-ZEC200-xxxx Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller Description The CCS Variable Air Volume (VAV) Zone Pressure Independent Damper Controllers
More informationParalleling Equipment
Paralleling Equipment PowerCommand Model 300 Digital Master Control Description The PowerCommand TM Digital MasterControl is a microprocessor-based paralleling system component, designed to directly interface
More informationGKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!
Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 550KVA Generator Set Specification. Ultra Silent, Extended Life! Page - 1 - of 5 3-Phase, 50Hz@1500RPM
More information3KW Off-grid Solar Power System LFP Battery
3KW Off-grid Solar Power System LFP Battery 1 CATALOGUE 1. S u m m a r y 3 2. T e c h n i c a l p a r a m e t e r 4 3. D i s p l a y a n d f u n c t i o n i n s t r u c t i o n 5 4. S e q u e n c e o f
More informationMedium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB
Catalogue Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv 97-1 96-1054 Medium Voltage 1 Indoor Current Transformers Cast Resin Insulated 1, 13.8, 17.5, 4 and 36 kv Index Description...
More informationCLASSIC MPPT CHARGE CONTROLLERS
CLASSIC MPPT CHARGE CONTROLLERS The worlds most sophisticated MPPT charge controller BAR NONE!!! THE CLASSICS The Classic line of MPPT charge controllers are one of the most powerful in the RE industry.
More informationPower Solution Supplier
Power Solution Supplier. Diesel & Gas Power Generators. Power Plant. Transformer Substation. CHP & CCHP System Guangdong Honny Power-Tech Co., Ltd GENERATOR FEATURE Engine and alternator shall be mounted
More informationThis generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
More information22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER
UHC 300 22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER OVERVIEW The HVAC building automation controls market requires a DDC controller that provides scalable, consolidated control in a fully programmable,
More informationUser manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A
User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A User manual Temperature Calibrator JOFRA CTC-140/320/650 A/B JOFRA CTC-1200 A Copyright 2005 AMETEK DENMARK A/S (123199-UK)
More informationSnapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle
LX10 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 3000 N 29 th Ct, Hollywood, FL 33020 U.S.A.
More informationMounting Installation Instructions LM, NM, AM, GM
709-0000 Rev G Mounting Installation Instructions LM, NM, AM, GM General Information Preliminary steps. Belimo actuators with NEMA or NEMA ratings should be mounted indoors in a dry, relatively clean environment
More informationDA/CL 74C Gear Motor and PCB
/L 74 Gear Motor and P Technical User Guide English: For other language variants of this document we refer to: Español: Para otras variantes del idioma de este documento, visite: Français: Pour les versions
More informationWARNING. Trouble Shooting Slide Out Control Box For In-wall Slim Rack Systems. Content. Table of Contents:
Trouble Shooting Slide Out Control Box 1510000199 For In-wall Slim Rack Systems Content Copyright Power Gear Issued: January 2013 #82-S0518, Rev. OA Read, understand and follow all instructions in Installation
More informationGraf Aqua Controller Programming & Setup to use with 3- way valve for backup systems
Graf Aqua Controller Programming & Setup to use with 3- way valve for backup systems Back-up System Overview The Graf Aqua Control and Three way valve combined will automate the operation of a backup water
More informationThis generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
More informationUser Instructions for WRC1021D. Doc
User Instructions for WRC1021D Doc. 0001-5989 CONTENTS 1.0 INTRODUCTION TO THE WRC1021D... 2 2.0 FUNCTIONAL DESCRIPTION... 3 3.0 POTENTIOMETERS, SWITCHES AND INDICATORS... 5 4.0 CALIBRATION AND START-UP
More informationDC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual
DC AC POWER INVERTER LIV 10 / LIV 20 / LIV 30 User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the Power Inverter. This
More informationMulti-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9
ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 9 (RTU1) CESMPU025REVAV9 Date: December 1, 2014 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV9 Unit features include: 25 ton MultiPath
More informationSERVICE MANUAL MU-A09YV - E1 MU-A09YV - MU-A12YV - E1 HFC. Wireless type Models SPLIT-TYPE, AIR CONDITIONERS. No. OB330 R410A CONTENTS.
SPLIT-TYPE, AIR CONDITIONERS Revision A: MU-A2YV - E can be connected to MCF-A2WV - E. Please void OB330. SERVICE MANUAL Wireless type Models E MU-A07YV - E MU-A09YV - MU-A2YV - E HFC utilized R40A No.
More informationProximity Sensors. Reference Information. Principles of Operation. Proximity Sensors
Reference Proximity Sensors Principles of Operation Inductive Proximity sensors are generally constructed with four main elements: (1) a coil and ferrite core assembly; (2) an oscillator; (3) a convertor/trigger
More informationCustomer Training Catalog Training Proposal. Training Description for Network Energy COMMERCIAL IN CONFIDENCE 1
Customer Catalog Proposal Description for Network Energy COMMERCIAL IN CONFIDENCE 1 Customer Catalog Proposal CONTENTS 1 Path... 3 1.1 Power Supply Path... 4 1.2 Data Center Facility Path... 5 1.3 UPS
More informationMAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS
MAKING MODERN LIVING POSSIBLE UniLynx Indoor Installation Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 Installation Sequence 2 Important
More informationPART NO CP-DOOR FRONT PANEL WINDOW PART NO CP-DOOR FRONT PANEL SECOND WINDOW PART NO CP-DOOR LOCK PART NO. 5026
5010 CP-DOOR FRONT PANEL WINDOW 5015 CP-DOOR FRONT PANEL SECOND WINDOW 5025 CP-DOOR LOCK 5026 CP-DOOR LOCKING CYLINDER 5027 CP MOUNTING BRACKET (PACKET OF 4) 5030 OBSOLETE CP-DOOR PUSH-BUTTON GREEN (HEAD
More informationThree Phase UPS Systems Range: 10 to 500kVA
Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying
More informationDescription. functions including single duct pressure dependent or pressure independent systems.
Description The Meridian Basic control system converts a single zone HVAC unit into a variable air volume/variable air temperature multiple zone system. The microprocessor based Zone Manager calculates
More informationInlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00
Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION
More informationCombined Ventilation Controller RVWS-T-224HA
Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage
More informationPowerScale kva Technical Specifications
PowerScale 10-50 kva Technical Specifications Copyright 2015 ABB, All rights reserved. TABLE OF CONTENTS 10.1 POWERSCALE SYSTEM DESCRIPTION... 3 10.2 TECHNICAL CHARACTERISTICS... 4 10.2.1 MECHANICAL CHARACTERISTICS
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationDX330 L/M/V. Safer. Faster. Easier SERIES DOTECH, INC. Universal Intelligent Controller for Screw Air Compressor
DX330 L/M/V SERIES Universal Intelligent Controller for Screw Air Compressor Please experience DOTECH s technology based on simplicity, multi-function and safety!! Easier Faster Safer DOTECH, INC http://www.dotech21.com
More informationNB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS
NB 0811 - NB 1511 NB 0831 - NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS LEN.MAN.UPS.069 Rev.2.00/2002 CONTENTS Safety Instructions 1 Introduction 3 2.1 FEATURE 3 2.2 UPS modules 4 How the UPS works 5 3.1
More informationInstallation Motor driven valve
Installation Motor driven valve Before the system may be taken into use, this manual must be studied carefully. Only, by MEDICVENT, authorized personnel are allowed to perform adjustments or repairs on
More informationMobile Access, TimeTec Smart Tripod Turnstile TTS 2200B Installation Manual
www.timeteccloud.com Mobile Access, TimeTec Smart Tripod Turnstile TTS 2200B Installation Manual TS2200: Tripod Turnstile TS2211: Tripod Turnstile with Controller and RFID Reader TS2222: Tripod Turnstile
More informationThis generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set is available with CE certification. Enclosed
More informationGRUNDFOS INSTRUCTIONS. Control HVAC. Installation and operating instructions. Other languages. net.grundfos.com/qr/i/
GRUNDFOS INSTRUCTIONS Control HVAC Installation and operating instructions Other languages net.grundfos.com/qr/i/98800750 English (GB) English (GB) Installation and operating instructions Original installation
More informationCENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge
CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey
More informationOBS-LE Series LED Digital Pressure Gauge. Operating Manual. Bar MPa KPa/KG. Psi
LED Digital ure Gauge / Transmitter / Switch OBS-LE Series LED Digital ure Gauge Operating Manual LED Alarms Bright LED Display Lock key / Shift Digits Engineering ure Units BAR MPr KPa/KG Programming
More informationCRE, CRIE, CRNE CRKE, SPKE, MTRE, CHIE, CME
GRUNDFOS INSTRUCTIONS CRE, CRIE, CRNE CRKE, SPKE, MTRE, CHIE, CME 1 & 3 phase Installation and operating instructions 2 English (US) Installation and operating instructions Original installation and operating
More informationSTRA-24 for chilled beams
STRA- Installation and commissioning manual STRA- for chilled beams STRA- is the room controller for the pressure independent (Pi) and constant air volume chilled beams. It is possible to set different
More informationØrstedsvej Silkeborg DENMARK
Ørstedsvej 4 8600 Silkeborg DENMARK Tel +45 86 80 58 66 Fax +45 86 80 58 67 E-mail mail@pronamic.com http:/www.pronamic.com Before connecting, operating or adjusting this product, please read these instructions
More informationAIS 5000 UPS kva 480 V. Installation Manual
AIS 5000 UPS 10-100 kva 480 V Installation Manual IMPORTANT! THIS DOCUMENT CONTAINS IMPORTANT SAFETY INSTRUCTIONS - PLEASE SAVE THESE INSTRUCTIONS! Contents Safety...1 IMPORTANT SAFETY INSTRUCTIONS - SAVE
More informationGKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!
Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 660KVA Generator Set Specification NO: GKP660KVA2012 c 2012 The Generator King (Pty) Ltd. Ultra Silent,
More informationMANIFOLDS & WATER TEMPERATURE CONTROL
MANIFOLDS & WATER TEMPERATURE CONTROL Overview Water based underfloor heating (UFH) systems work by turning the entire floor into one large low temperature radiator which is heated via a network of pipes
More informationShenzhen Sine Electric Co., Ltd.
Page 1 of 5 Favorite Contact 中文 Please enter key words 提交查 Home Products Solutions Service About us Products EM500 Open loop Inverter Your current location:home > Products Standard Inverters EM500 Open
More informationSpeed-Pro EFI Installation Manual
Speed-Pro EFI Installation Manual Speed-Pro Electronics Installation Manual Page The wiring harness is labeled on each of the connectors to simplify installation. Your application may not require the use
More information