USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Similar documents
USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

High Pressure, Subplate Mounted Directional Control Valves

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

High Pressure, Subplate Mounted Directional Control Valves

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves. Features. Application. Operation

Directional Controls

D05 Directional Control Valves

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Features. Specifications

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

PACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE.

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

D03 FluiDyne Valves. ENGINEERING DATA

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Directional Control Valves. General Description. Operation. Features

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Monoblock directional control valves DL - Directional control valve

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Controls

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

Directional Controls

Directional Control Valves

Proportional Valves. Proportional solenoid valves for pressure and flow control

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. Application. Features. Operation

Pilot Operated Directional Valves

Directional Control Valves. Application. Features. Operation.

Directional Control Valves. Application. Features. Operation

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Valves. Pilot Operated Directional Valves. Vickers. Service Data

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Directional Controls

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

Directional Controls

Directional Control Valve Series D1VW

Pilot-Operated Directional Control Valves Series D3 - D11

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Control Valve Series 4D01 (DENISON)

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

SOLENOID VALVES NFPA D03 NFPA D05 D03 & D05 SERIES 35- SOLENOID VALVES. Features. Internal Structure NFPA SIZE: D03 & D05

Directional Controls

HYDRAULIC MOTORS HP APPLICATION GENERAL. » Conveyors» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32

(F*) - DG5V -10- * - (R) - (B) - **(L) - (**) - (X) - (*) - (E) - (T) - (*) - (V)M - (S*) - * ** * * (L) - (*) ** - (***) (EN***)

HYDRA-PAC SYNCHRONOUS HYDRAULIC POWER UNIT

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

Cartridge Valves Technical Information Directional Valves DCV 03

Directional Control Valves. Features. Application. Operation

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES

Pilot Operated Pressure Relief Valve Series R5V (Denison)

C560 Electronic Time Relays

3/2 and 4/2 directional seat valves with solenoid actuation

EManually Operated Directional Valves

VSD*S -MONITORED DIRECTIONAL CONTROL VALVES

Pilot Operated Directional Valves

PowerFlow D03 Directional Control Valves

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

ISO 9001 SAE SPOOL VALVES

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter. Min.

Chapter 2: Directional Control Valves

The H Series Leak-Proof, High-Pressure Valves Versa Products Company has been supplying high quality pneumatic and hydraulic directional control valve

ISO 5599/ Series Technical and Operating Data

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Directional Control Valves. Features. Application. Operation

Sepehr Hydraulic Asia

EManually Operated Directional Valves

Directional Control Valve Series D3W Soft Shift

Rexroth Hydraulics. Pressure reducing valve, pilot operated, type 3DR 3DR 10 P 6X Y 00 RE /10.97

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Available manual, pneumatic, and hydraulic spool control kits.

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

VSD05M-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES

Bulletin HY M6/US Service Bulletin. Series D1VW, H Style 91 Design. Effective: May 1, Directional Control Valves

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

Bulletin HY M2/US Service Bulletin. Series D1VW, C Style 91 Design. Effective: May 1, Directional Control Valves

XSz 8... XSz 50 Solenoid actuated fail-safe safety valve

Electrical Interface Dimensional Drawings Connector Kits

Transcription:

SPECIFICAIONS D05 Pattern Directional Control Valves Also refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONAC INFORMAION USA Headquarters Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 U.S.A. el: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics.com Power Units & Systems Dynex/Rivett Inc. 54 Nickerson Road Ashland, MA 01721 U.S.A. el: 508-881-5110 FAX: 508-881-6849 E-mail: ashland@dynexhydraulics.com European Sales Dynex/Rivett Inc. Unit C5 Steel Close, Little End Road, Eaton Socon, Huntingdon, Cambs. PE19 8 United Kingdom el: +44 (0) 1480 213980 FAX: +44 (0) 1480 405662 E-mail: sales@dynexhydraulics.co.uk For more information visit our web site: www.dynexhydraulics.com BROCHURE NOES: Consult the Dynex sales department for a review of any application which requires operating above the rated flows or pressures, or higher than normal operating temperatures. Specifications shown were in effect when published. Since errors or omissions are possible, contact your sales representative for the most current specifications before ordering. Dynex reserves the right to discontinue or change designs at any time without incurring any obligation. DYNEX High Pressure Hydraulics Copyright Dynex/Rivett Inc. Bulletin dynexvesd05specs-0402

Valves Control Flow to 40 U.S. gpm (151 L/min) hese reliable valves operate with superior efficiency at pressures to 5000 psi (350 bar). Exceptional flow characteristics are achieved with large internal flow passages with uniform flow areas throughout the body coring. Efficiency is enhanced with the use of the Dynex standard subplate, which takes advantage of the valve s special double tank port design. 6500 Series Explosion Proof 6500 Series Double Solenoid EFFICIEN LOW PRESSURE DROP he result is exceptionally low loop pressure drop at 20 U.S. gpm (76 L/min) nominal flow: 80 psi (6 bar) with open center spools; 104 psi (7 bar) with closed center spools ( P loop = P A + B ). LONG-LIFE OPERAION Wet-armature solenoids provide low noise and leak-proof shifting. Reliable manual override is assured with noncorrosive override pins. apered o-ring counterbores improve sealing at the mounting surface. A four-land spool design assures exceptionally smooth spool travel. Additional outboard lands provide greater support, eliminating spool imbalance. HIGH PRESSURE ANK POR High pressure tank port capability gives you greater circuit flexibility, especially with series circuits. HIGH-ORQUE MOUNING High-torque mounting to 12 lb ft (16 N m) prevents weepage between mounting surfaces, especially important when using sandwich valves. SIMPLIFIED SERVICE Complete spool interchangeability and a large wiring box make these valves easy to install. Servicing of solenoids is made easier with handtightened knurled knob lock nuts. 6800 Series Hydraulic Piloted SPECIFICAIONS For a description of spools, operator functions, electrical options and operating recommendations refer to dynexdcvoperating.pdf. Mounting Subplate, N.F.P.A. D05 (CEOP 5) Pattern Operator Options 6100 Series: Manual Lever; 6500 Series: Direct Solenoid; 6800 Series: Hydraulic Piloted; 6900 Series: Air Piloted B P Spool travel is exceptionally smooth because of a four-land spool design which provides greater support, eliminating spool imbalance. A 6900 Series Air Piloted Rated Flow Nominal: 20 U.S. gpm (76 L/min); Maximum: See ypical Valve Performance on page 4. Rated Pressure 5000 psi (350 bar) Maximum ank Port Pressure (Port ) Solenoid Models, Standard: 1500 psi (105 bar); High Pressure Option ( HP ): A.C. Models, 2000 psi (140 bar); D.C. Models, 2500 psi (170 bar) Manual Lever Models: 3000 psi (210 bar) Hydraulic Piloted Models: 3000 psi (210 bar) Air Piloted Models: 3000 psi (210 bar) Response ime (Full Stroke) Solenoid Energized: A.C., 10-20 ms; D.C., 25-35 ms Spring Returned: A.C., 15-20 ms; D.C., 30-40 ms 2

SOLENOID SPECIFICAIONS Models are available with A.C. or D.C. solenoids. he table shows electrical specifications for these valves. Electrical Connections Standard Wiring Box with leads; Optional erminal Strip, Cable Grip or Pin Connector (N.F.P.A. standard 3.5-29-1980; A.N.S.I. standard B93,55M-1981); Optional Plug-In-erminal Solenoids fit DIN Connector Standard 43650 (Hirschmann GDM 209) Explosion Proof Option ( EPW ) Solenoids with special enclosures are approved by UL and CSA for use in hazardous locations. Available with A.C. or D.C. solenoids. UL Classification: Class I, Group C,D; Class II, Group E,F,G ELECRICAL DAA Solenoid Code Input Voltage (Volts) Frequency (Hz) Inrush Current (Amps) Holding Current (Amps) Holding Power (Watts) Coil Resistance (Ohms ± 10%) 24/DF 24 A.C. 50 23.00 4.10 38 0.56 (Dual Frequency) 24 A.C. 60 21.00 3.15 38 0.56 115/DF 110 A.C. 50 4.80 0.88 37 10.20 (Dual Frequency) 115 A.C. 60 4.30 0.72 35 10.20 230/DF 220 A.C. 50 2.40 0.44 37 40.80 (Dual Frequency) 230 A.C. 60 2.20 0.36 35 40.80 460/DF 440 A.C. 50 1.30 0.23 37 188.50 (Dual Frequency) 460 A.C. 60 1.20 0.20 35 188.50 12VDC 12 D.C. 48 3.00 24VDC 24 D.C. 48 12.00 250VDC 250 D.C. 48 1300.00 12VDC EPW 12 D.C. 48 3.00 24VDC EPW 24 D.C. 48 12.00 110/50 EPW 110 A.C. 50 4.20 1.00 43 10.72 115/60 EPW 115 A.C. 60 3.90 8.90 43 10.47 220/50 EPW 220 A.C. 50 2.09 0.50 43 43.35 ➀ Ordering Codes shown are for standard wire leads with wiring box. Plug-In-erminal solenoids (Hirschmann GDM 209) are also available; see ypical Model Code on page 8. MANUAL LEVER MODELS Lever operated models offer superior handle position flexibility. Choose from eight different lever locations for complete operator convenience. hese high performance valves provide a combination of operating efficiency and circuit layout flexibility. he valves are rated for 20 U.S. gpm (76 L/min) nominal flow at pressures to 5000 psi (350 bar). Higher intermittent flows may be possible with some models. Consult the Dynex sales department. EASY INSALLAION, SERVICING With complete spool interchangeability and multiple lever positions which can be adjusted in the field, these valves are easy to install and service. Choose from eight handle locations, with four positions on either port A or port B end of valve. o specify, see drawing at right and ypical Model Code on page 31. his feature allows you to put the handle where it s best for your circuit design, for complete operator convenience. Changing the location is done by removing the bracket and handle assembly, and rotating it to the desired position. A9 or B9 A6 or B6 A12 or B12 A3 or B3 Handle Positions Viewed from Port A or Port B End of Valve 3

ypical Valve Performance FLOW CAPACIY BAR PSI SOLENOID MODELS he flow capacity curves show typical performance for each internal operator and spool. he letters in the Flow Curve Reference table identify the appropriate curve. PRESSURE 350 300 250 200 150 100 50 0 5000 4000 3000 2000 1000 U.S. GPM N AB F K E G H J L M C D 5 10 15 20 25 30 35 40 AN EXAMPLE In the table under spool type 01, curve F is called out for Operator Code 4, A.C. Models. Looking at the curves, F indicates that the maximum flow is 20 U.S. gpm (76 L/min) up to the maximum pressure rating of 5000 psi (350 bar). PILO OPERAED MODELS he maximum flow for pilot operated valves is dependent on pilot pressure. Generally, the maximum flow for most pilot operated models is 20 U.S. gpm (76 L/min). Minimum Pilot Pressure he table shows the minimum pressure required to shift the spool, for various flow capacities. hese values are based on zero tank pressure. As back pressure increases above zero, the minimum pilot pressure must be increased by the same level. Maximum Pilot Pressure Hydraulic Piloted: 3000 psi (210 bar); Air Piloted: 200 psi (14 bar) Volume Maximum required to shift spool full stroke: Hydraulic, 0.018 in 3 (0,30 cm 3 ); Air, 0.640 in 3 (10,49 cm 3 ) 6800 Series Hydraulic Piloted 6900 Series Air Piloted L/MIN. 25 FLOW CURVE REFERENCE Operator Code 1 2 3 4 5 6 50 75 FLOW Solenoid Spool ype ype 0 1 3 4 01 2 2R 32 32R 36 A.C. N B A A K K E D.C. and EPW N C A A J J G A.C. N B A A K K E D.C. and EPW N C A A J J G A.C. N D A A K K E D.C. and EPW N D A A J J G A.C. N K N N F A A K K E D.C. and EPW N N N N F A A J J G A.C. N K N N F A A K K E D.C. and EPW N N N N F A A J J G A.C. N K K M F A A K K E D.C. and EPW N H M L F A A J J G MINIMUM PILO PRESSURE Series Spool ype 5 U.S. gpm (19 L/min) 0 300 20,7 310 21,4 325 22,4 1 300 20,7 360 24,8 600 41,4 3 300 20,7 360 24,8 600 41,4 4 300 20,7 360 24,8 450 31,0 01 300 20,7 360 24,8 2 or 2R 300 20,7 360 24,8 600 41,4 32 or 32R 300 20,7 360 24,8 600 41,4 36 300 20,7 360 24,8 600 41,4 0 25 1,7 25 1,7 25 1,7 1 25 1,7 30 2,1 35 2,4 3 25 1,7 30 2,1 35 2,4 4 20 1,4 25 1,7 25 1,7 01 25 1,7 25 1,7 2 or 2R 25 1,7 30 2,1 35 2,4 32 or 32R 25 1,7 30 2,1 35 2,4 36 25 1,7 30 2,1 35 2,4 100 Pilot Pressure At: 10 U.S. gpm (38 L/min) 125 150 20 U.S. gpm (76 L/min) psi bar psi bar psi bar 4

VALVE EFFICIENCY Exceptional flow characteristics are achieved with large internal flow passages. Efficiency is enhanced with the use of our standard subplate, which takes advantage of the valve s special double tank port design. he result is exceptionally low pressure drop. At 20 U.S. gpm (76 L/min) flow, loop pressure drop is a low 102 psi (7,0 bar) with open center spools (ype 1) and 121 psi (8,3 bar) with closed center spools (ype 0). Determining Pressure Drop he curves show resistance to flow for various spool types. he Curve Reference table identifies the proper pressure drop curve for each spool and flow path. An Example In the table under spool ype 1, curve D is called out to determine the pressure drop for P A. Looking at the curves, D indicates a drop of about 28 psi at 12 U.S. gpm (1,9 bar at 45 L/min) o determine total loop drop, the individual pressure drops for A B and B (or P B and A ) must be added. PRESSURE DROP ( P) PRESSURE BAR 18 16 14 12 10 8 6 4 2 0 PSI 250 200 150 100 50 U.S. GPM L/MIN. CURVE REFERENCE 5 10 15 20 25 30 20 40 FLOW Flow Spool ype Path 0 1 3 4 01 2 2R 32 32R 36 P A D D D D B C C D D D P B D D D D B C C D D D A F H H G E H H F F G B F H H G E H H F F G P D B 60 A E 80 100 B C D F G H Installation and Dimensions GENERAL VALVE MOUNING his valve has a second port into a common tank passageway, for lower pressure drop and increased efficiency. he mounting surface drawing shows the standard N.F.P.A. D05 (CEOP 5) pattern, with the optional second port. Mounting face must be flat within 0.0004 inch/4.0 inches (0,010 mm/102 mm) with a surface finish of 32 microinch (0,80 µm) AA. Port o-rings are included with all valves. Mounting bolts must be ordered separately,.250-20 U.N.C. hreaded x 1.00 inch (25,4 mm), Grade 8 or better; four required. Recommended mounting torque is 12 lb ft (16 N m) maximum. 2.63 (66,8).250 (6,35) 19 (37,31) 2.000 (50.80) 1.062 (26,97).125 (3,18) B 3.125 (79,38) P.656 (16,66) A.438 (11,13) 5 PORS 1.281.844 (32,54) (21,44).41 (10,4) 32 (0,80).0004/4.0 (0,010/102).250-20 U.N.C. 2B HREADED, DEEP, 4 MOUNING HOLES.50 (12,7) Recommended Minimum Mounting Surface, N.F.P.A. D05 (CEOP 5) Pattern With wo Ports () Into Common ank Passageway 5

SOLENOID MODEL DIMENSIONS Refer to the basic installation drawing, which shows typical dimensions common to all D05 valves. Dimensions are shown for both A.C. and D.C. models, with D.C. configuration shown printed in gray. Single Solenoid: A.C., 8.1 lb (3,7 kg); D.C., 9.5 lb (4,3 kg) Double Solenoid: A.C., 9.6 lb (4,4 kg); D.C., 12.6 lb (5,7 kg) 4.94 (125,6).62 (15,7) 1.75 (44,4) 1 2.75 (69,8) MANUAL ACUAOR PIN 1.34 (34,0) 1/2 N.P..-14 SANDARD ELECRIC ENRY, ONE EACH SIDE CLEARANCE O REMOVE COIL 1.90 (48,3) A.C. 3.20 D.C. (81,3) SOLENOID A FOR YPE 0, 1, 3, 4, SOLENOID B FOR YPE 01 SPOOL 3.89 (98,8) 2.96 (75,2).250-20 U.N.C. HREADED x 1.00 (25,4) LONG MOUNING BOLS, 4 REQUIRED; ORQUE: 12 LB F (16,3 N M) 2.98 A.C. (75,7) 4.32 D.C. (109,7) 5.00 (127,0) 10.34 A.C. SOLENOID (262,6) 13.01 D.C. SOLENOID (330,5) SOLENOID B FOR YPE 0, 1, 3, 4, 2, 2R, 32, 32R, 36, 03 SPOOLS; SOLENOID A FOR YPE 01 SPOOL 6500 Series, Double Solenoid Models SOLENOID A FOR YPE 0, 1, 3, 4, 2, 2R, 32, 32R, 36 SPOOL SOLENOID B FOR YPE 01 SPOOL 4.91 (124,7) 1/2 14 N.P.. ELECRIC ENRY, YPICAL EACH END REMOVE PLUG (3/8" INERNAL HEX) FOR ACCESS O HIS END 4.91 (124,7) SOLENOID B FOR YPE 0, 1, 3, 4, 2, 2R, 32, 32R, 36 SPOOL, SOLENOID A FOR YPE 01 SPOOL 7.67 (194,8) (A.C. COIL) 9.02 (D.C. COIL) (229,11) (9,6) (9,6) 7.67 (194,8) (A.C. COIL) 9.02 (D.C. COIL) (229,11) 6500 Series, Single Solenoid Models EXPLOSION PROOF SOLENOIDS Solenoids with special enclosures are approved by UL and CSA for use in hazardous locations. Overall length of single EPW solenoid models (not shown) is 9.31 inches (236,5 mm). Note that spacer plate, part number 10711320, is required when valves are mounted on manifolds and side outlet subplates. Valves can be mounted without removing nameplate. Single Solenoid: 15.7 lb (7,1 kg); Double Solenoid: 24.8 lb (11,2 kg) MANUAL ACUAOR PIN 3.63 (92,2) 45 LEADWIRES (2) YPICAL #18 AWG APPROXIMAELY 18 (457) LONG 1/2 14 N.P.. SANDARD ELECRIC ENRY, 360 ROAABLE 1.62 (41,2) 4.87 (123,7) 0 1 2.75 CLEARANCE O (69,8) REMOVE COIL 3.87 (98,3) SOLENOID POSIION LIMI WIH SIDE OULE SUBPLAE OR SANDWICH VALVE SOLENOID A FOR YPE 0, 1, 3, 4, 2, 2R, 32, 32R, 36, 03 SPOOLS SOLENOID B FOR YPE 01 SPOOL GROUNDWIRE YPICAL #18 AWG (GREEN INSULAION) APPROXIMAELY 18 (457) LONG NOE: KEEP AIR GAP BEWEEN SOLENOID AND VALVE BODY CLEAN 13.86 (352,0) 1.64 (41,7) SOLENOID B FOR YPE 0, 1, 3, 4, 2, 2R, 32, 32R, 36, 03 SPOOLS SOLENOID A FOR YPE 01 SPOOL 1.00 (25,4).250-20 U.N.C. HREADED x 2.00 (50,8) LONG MOUNING BOLS, 4 REQUIRED; ORQUE: 12 LB F (16,3 N M) SPACER NO. 10711320 6500 Series, Double EPW Solenoid Models 6

MANUAL OPERAED MODELS Manual lever valves allow you to choose from eight handle locations, with four positions on either port A or port B end of valve. o specify, see drawing on page 26 and ypical Model Code on page 8. Valves can be mounted without removing nameplate. 7.8 lb (3,5 kg) HANDLE POSIION FOR O A FOR YPE 0, 1, 3, 4, O B FOR YPE 01 SPOOLS HANDLE POSIION FOR CENER FLOW FUNCIONS HANDLE POSIION FOR O B FOR YPE 0, 1, 3, 4, 2, 2R, 32, 32R, 36, 03 SPOOLS; O A FOR YPE 01 SPOOL 19º 7º 19º HANDLE POSIION FOR O B FOR YPE 0, 1, 3, 4, 2, 2R, 32, 32R, 36, 03 SPOOLS; O A FOR YPE 01 SPOOL 3.19 (81,0) 1.84 (46,7) 1.34 (34,0).84 (21,3).62 (15,7) 7.80 (198,1) 6.26 (159,1) 8.41 (213,7).71 (18,0).250-20 U.N.C. HREADED x 1.0 (25,4) LONG MOUNING BOLS, 4 REQUIRED; ORQUE: 12 LB F (16,3 N M) 1 2.75 (69,8) 6100 Series, Manual Lever Operated HYDRAULIC PILOED MODELS Single and double actuator models are available. Overall length of single configuration (not shown) is 6.60 inches (167,6 mm). Valves can be mounted without removing nameplate. Single Actuator: 7.1 lb (3,2 kg); Double Actuator: 7.8 lb (3,5 kg).62 (15,7) 1.25 (31,8) HEX 1 2.75 (69,8) 3.19 (81,0) 1.34 (34,0) PILO A FOR YPE 0, 1, 3, 4, PILO B FOR YPE 01 SPOOL PILO PORS (2) NO. 6 S.A.E..250-20 U.N.C. HREADED x 1.00 (25,4) LONG MOUNING BOLS, 4 REQUIRED; ORQUE: 12 LB IN ( 16,3 N M) 2.03 (51,6) 8.43 (214,1) 6800 Series, Double Hydraulic Piloted Models PILO B FOR YPE 0, 1, 3, 4, PILO A FOR YPE 01 SPOOL AIR PILOED MODELS Single and double actuator models are available. Overall length of single configuration (not shown) is 7.13 inches (181,1 mm). Valves can be mounted without removing nameplate. Single Actuator: 8.0 lb (3,6 kg); Double Actuator: 9.5 lb (4,3 kg) 1.88 (47,8) HEX.62 (15,7) 1 2.75 (69,8) 3.19 (81,0) 1.34 (34,0) PILO A FOR YPE 0, 1, 3, 4, PILO B FOR YPE 01 SPOOL PILO PORS (2) NO. 6 S.A.E..250-20 U.N.C. HREADED x 1.00 (25,4) LONG MOUNING BOLS, 4 REQUIRED; ORQUE: 12 LB IN (16,3 N M) 2.56 (65,0) 9.49 (241,0) 6900 Series, Double Air Piloted Models PILO B FOR YPE 0, 1, 3, 4, PILO A FOR YPE 01 SPOOL 7

ypical Model Code 6 5 4 0 D05 115/DF R SL 1 0 Valve ype 6 Subplate Mounted Directional Control Valve Size D05 20 U.S. gpm (76 L/min) Nominal Flow, N.F.P.A. D05 (CEOP 5) Pattern Reverse Flow Operator (Code 4 and 6 Only) R Code 4: wo Position; Spring Centered, Actuator Offset (P B) Code 6: wo Position; Spring Offset (P B), Actuator Centered Design Number Modification Number Actuator 1 Manual Lever 5 Solenoid Operated 8 Hydraulic Piloted 9 Air Piloted Internal Operator 1 wo Position; Spring Offset (P B), Actuator Offset (P A) 2 wo Position; Spring Offset (P A), Actuator Offset (P B) 3 Manual Lever Only: hree Position, Detented; Others: wo Position; Actuator Offset, Detented ➀ 4 wo Position; Spring Centered, Actuator Offset (P A) ➁ 5 hree Position; Spring Centered, Actuator Offset 6 wo Position; Spring Offset, Actuator Centered ➁ 7 Manual Lever Only: wo Position, Detented ➀ Only available with ype 0 and ype 1 spools. ➁ Not available with Manual Lever Operated valves. Spools 0 2 1 2R 3 32 Lever Position (Manual Models Only) A12 12 o clock position, on port A end of valve A9 9 o clock position, on port A end of valve A6 6 o clock position, on port A end of valve A3 3 o clock position, on port A end of valve B12 12 o clock position, on port B end of valve B9 9 o clock position, on port B end of valve B6 6 o clock position, on port B end of valve B3 3 o clock position, on port B end of valve C M CG SL HP Options (Solenoid Models Only) CSA and UL Recognized Coils (Etched with Symbol) ➀ Hand Actuated Manual Override ➁ erminal Strip ➁➂ Cable Grip, for to.44 inch (9,5 to 11,1 mm) O.D. machine tool cable ➁➂ Solenoid Lights (Available 115/DF A.C. Only) ➁➂ High Pressure ank Port: 2300 psi (160 bar) maximum A.C. models 3000 psi (210 bar) maximum D.C. models BH3A 3-pin Connector (N.F.P.A. standard 3.539-1980), for single solenoid models, on port A end of valve ➁➂➃ BH3B 3-pin Connector, for single solenoid models, on port B end of valve ➁➂➃ BH5A 5-pin Connector, for single or double solenoid models, on port A end of valve ➁➂➃ BH5B 5-pin Connector, for single or double solenoid models, on port B end of valve ➁➂➃ ➀ Available with 115/DF solenoids only. For other voltages, consult the Dynex sales department ➁ Option not available with EPW solenoid models. ➂ Option not available with Plug-In-erminal solenoid models. ➃ N.F.P.A. standard 3.539-1980; A.N.S.I. standard B93.55M-1981. ➀ 4 32R 01 ➀ 36 Closed crossover 03 SANDARD SOLENOIDS: 24/DF Dual Frequency, 24/60, 24/50 115/DF Dual Frequency, 115/60, 110/50 230/DF Dual Frequency, 230/60, 220/50 460/DF Dual Frequency, 460/60, 440/50 12VDC Direct Current, 12 Volts 24VDC Direct Current, 24 Volts 250 VDC Direct Current, 250 Volts 12VDC EPW Explosion Proof Solenoids 24VDC EPW Explosion Proof Solenoids 110/50 EPW Explosion Proof Solenoids 115/60 EPW Explosion Proof Solenoids 220/50 EPW Explosion Proof Solenoids Electrical Solenoid Options PLUG-IN ERMINAL SOLENOIDS: ➀ 115/HAC Dual Frequency, 115/60, 110/50 230/HAC Dual Frequency, 230/60, 220/50 12/HDC Direct Current, 12 Volts 24/HDC Direct Current, 24 Volts For Other Voltages, Consult the Dynex Sales Department ➀ Fits DIN Connector Standard 43650 (Hirschmann GDM 209) 8