Ejector Valve Unit Series ZYY/ZYX

Similar documents
Vacuum Ejector with Solid State Timer

Vacuum Ejector. Series ZM

Vacuum Ejector. Series ZM Applications

3 Port Solenoid Valve

Series ZM Applications

Vacuum Ejector. Adaptable for manifold application

Specifications. Fluid Ambient and fluid temperature ( C)

Vacuum Module. Series ZX. Ejector System/Vacuum Pump System

Series ZM Applications

Series ZM Applications

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Vacuum pump system type

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Vacuum Equipment. Application. Series

Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc.

Large Size Vacuum Module: Ejector System/Vacuum Pump System. Nozzle size (mm): ø1.0, ø1.3, ø1.5, ø1.8, ø2.0

How to Order. 0.5 mmø 0.7 mmø mmø mmø mmø mmø mmø. Maximum vacuum pressure S L. 88 kpa 48 kpa. SUP.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Air Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC

Low Differential Pressure Sensor ±1% F.S.

Series VQ Port Solenoid Valve

3 Port Solenoid Valve

LCD Readout Digital Pressure Switch

Soft Start-up Valve. AV2000/3000/4000/5000 Series


Technical information for LFU20-Z07-3A-X2

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Series AV2000/3000/4000/5000

3 Port Solenoid Valve

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

Large Size Vacuum Module:

Space Saving Vacuum Ejector/Vacuum Pump System

3 Port 3 Position Valve

Blanking. External Vacuum spec. (V) Standard pilot spec. (R) Vacuum spec. (V) Standard

2-Color Display High-Precision Digital Pressure Switch

Related vacuum products

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K. Note 6)

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Compact Vacuum Ejector

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

3 Port Solenoid Valve Direct Operated Poppet Type

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

MULTISTAGE MICRO EJECTORS

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

5 Port Solenoid Valve

Pilot Operated 2 Port Solenoid Valve for Dry Air

Large Size Vacuum Module:

Series VP3145/3165/3185

Air Catch Sensor ISA2

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

Series SYJ300/500/700

Pilot Operated 2 Port Solenoid Valve for Dry Air

Series VP3145/3165/3185

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

AV2000-A/3000-A/4000-A/5000-A

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Compact Vacuum Unit. 46 g Single unit weight. New RoHS. 17% reduced 21% Ejector/Vacuum Pump System. 10 mm mm mm.

Trimmer Auto Switch Series D- 7K/D-R K

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K

Compact Vacuum Unit Ejector/Vacuum Pump System. 46 g. New. 17% reduced 21% 10 mm mm mm. Series ZB. Response time of the valve: 5 ms

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

2-Color Display Digital Pressure Switch

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Vacuum Release Valve with Restrictor

S Y 3 A F NFZD

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Non-Contact Sensor for Workpiece Placement Verification

l/min (Comparison under Nozzle diameter: ø0.3, Vacuum pressure: 60 kpa) New

Transcription:

Ejector Valve Unit Series ZYY/ZYX Series ZYY3 (Solenoid valve: SY3) Nozzle diameter: ø.7, ø1. Type S: Standard type L: Large flow type Ejectors and solenoid valves can be mounted on the same manifold. Centralized wiring of ejector (ZYX3: Individual pressure switch not included) Series ZYX3 (Solenoid valve: SX3) ZA ZX ZR ZM ZMA ZQ ZH ZU ZL ZY ZF ZP SP ZCUK AMJ AMV AEP HEP Related Equipment 181

Ejector Valve Unit Series ZYY/ZYX How to Order Ejector Valves for ZYY3 Y3 ZY Y3 Series SY3 5 LOU L Z 1 S 15 Lead wire/ Voltage suppressor specifications LOU Connector box type G H L LN LO M MN MO S Z R U Rated voltage DC specifications 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Electrical entry 24, 12, 6, 5, 3 VDC/1, 11, 2, 22 VAC Grommet L plug connector M plug connector AC specifications (5/6 Hz) 1 2 3 4 Lead wire length 3 mm Lead wire length 6 mm With lead wires (Length 3 mm) Without lead wires Without connector With lead wires (Length 3 mm) Without lead wires Without connector Light/Surge voltage suppressor Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) D E 1 VAC 2 VAC 11 VAC [115VAC] 22 VAC [23VAC] Note) The connector box type and serial transmission type are only available with 5 (24 VDC). Note 1) Types LN and MN are equipped with sockets (2 pcs.). Note 2) Not compatible with the FU electrical entry which is used on Series SY3 plugin type manifolds (45F, 45P, 45T, 45T1, 45S, 45S1, 45S2, 45S3 ). 182 For electrical entry types G, H, L, M Note 1) Types R and U are DC only. Note 2) Since surge voltage is prevented with a rectifier in the case of AC, there is no type S. Manual override Non-locking push type Push-turn locking slotted type Push-turn locking lever type S L E 1 84 kpa 53 kpa Nozzle diameter 7.7 mm 1 1. mm None With silencer Max. vacuum pressure Wiring specifications () Grommet Lead wire length.6 m L type Lead wire length 3 m C Lead wire length.6 m Connector CL Lead wire length 3 m type CN Connector type Output specifications () 14 15 16 17 18 19 55 Analog, no output, 3 turn setting Analog, no output, 2 degree setting NPN open collector, double output Analog, no output, 3 turn setting NPN open collector, double output Analog, no output, 2 degree setting Analog, with output, 3 turn setting Analog, with output, 2 degree setting PNP open collector, single output Analog, no output, 2 degree setting MN None With vacuum switch Manifold block With manifold block None

Ejector Valve Unit Series ZYY/ZYX S Z X3 ZY X3 5 6 V S R Series SX3 Rated voltage DC specifications 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Common specifications N Positive common Negative common Note 1) The symbol is for the single grommet type and when not equipped with light/surge voltage suppressor. Note 2) Match with the common specification of the manifold. Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor LOZ MZ Electrical entry G Lead wire length 3 mm Grommet H Lead wire length 6 mm L With lead wires (Length 3 mm) L plug LN Without lead wires connector LO Without connector M With lead wires (Length 3 mm) M plug MN Without lead wires connector MO Without connector Note) For types LN and MN, the single solenoid has 2 sockets and the double solenoid has 3 sockets. Light/Surge voltage suppressor For electrical entry types G, H, L, M D 5 Note 1) The serial transmission type is 5 (24 VDC) only. Note 2) V, S and R specifications are 45T, 45T1. How to Order Ejector Valves for ZYX3 Manual override Non-locking push type Push-turn locking slotted type 1 S 15 S L 1 84 kpa 53 kpa Nozzle diameter 7.7 mm 1 1. mm E None With silencer Wiring specifications () Output specifications () 14 Analog, no output, 3 turn setting 15 Analog, no output, 2 degree setting NPN open collector, double output 16 Analog, no output, 3 turn setting NPN open collector, double output 17 Analog, no output, 2 degree setting 18 Analog, with output, 3 turn setting 19 Analog, with output, 2 degree setting PNP open collector, single output 55 Analog, with output, 2 degree setting F MN Max. vacuum pressure Lead wire/ Voltage suppressor specifications Plug-in type LOZ Serial transmission type L C CL CN None With vacuum switch Grommet type Connector type Lead wire length.6 m Lead wire length 3 m Lead wire length.6 m Lead wire length 3 m Connector type Plug-in/Non plug-in type Plug-in type Non plug-in type Manifold block With manifold block None ZA ZX ZR ZM ZMA ZQ ZH ZU ZL ZY ZF ZP SP ZCUK AMJ AMV AEP HEP Related Equipment 183

Series ZYY/ZYX How to Order Manifold Valves for ZYY3/ZYX3 (Split Base/DIN Rail Mounting) For solenoid valve and ejector valve combination Y 3 SS5 45 X 3 Change to ZZY SY3/SX3 Same as ordering manifold. However, (optional DIN rail) is a special order specification. Ejector valve numbers ZZY Y 3 X 3 45 J 1 U Note 1) With ejector Enter the following together with the manifold number: 1. Part no. of solenoid for SY3/SX3 2. Part no. of ejector valve for ZYY3/ZYX3. [Example: When individual wiring type model 45 for SY3 is selected] ZZY Y3-45-4D-C6- SY3 manifold model SX3-75-1A SY314-5LZ SY324-5LZ ZYY35LZ-1S-E15C Ejector valve number 1SET 1SET 1SET 1SET J1U 1SET is the symbol for a built-in assembly. Add the symbol at the beginning of part numbers for solenoid valves, etc. to be mounted, and enter these together in order from the D side. Ejector valve ZYY35LZ-1S-E15C Double solenoid (24 VDC) SY324-5LZ Single solenoid (24 VDC) SY314-5LZ Blanking plate assembly SX3-75-1A Cylinder port size C6 : With ø6 One-touch fitting Manifold base (4 stations) ZZYY3-45-4D-C6-J1U Number of ejectors 1 to 1 Ejector mounting position U D U side D side Note 1) The combined total of solenoid valve and ejector valve stations is a maximum of 2 stations. (Example: When there are 12 solenoid valve stations, there are 8 ejector stations.) For ejector valves only (Without solenoid valves: individual wiring type is compliant only.) ZZY With ejector Number of ejectors 1 to 1 J 1 U U side Stations 3 2 1 D side Example) ZYY-J3U ZYY35MZ-1S1-E15C-F ZYY35MZ-1S1-F 1SET 2SETS 1SET 184

Ejector Valve Unit Series ZYY/ZYX Series SY3/SX3 in manifold/split base combinations DIN rail mount type can be mounted Compact (integrated construction of ejector and valve) Copper-free and fluorine-free measures implemented ZYY3 Series ZYX3 Series Ejector Valve Specifications Ejector valve model ZY 3 7S ZY 3 7L ZY 3 1S ZY 3 1L Nozzle diameter (mm).7 1. Max. suction flow rate N (l/min (ANR)) Max. vacuum pressure (kpa) 11 84 18 53 22 84 32 53 Maximum operating pressure Standard supply pressure Operating temperature range.6 MPa.45 MPa 5 to 5 C Supply/Release Valve Specifications Valve type Pilot type 3 position 3 port solenoid valve Type of actuation Closed center Fluid Air Operating pressure range.2 to.6 MPa Ambient and fluid temperature 5 to 5 C Allowable voltage fluctuation 1 to +1% Grommet : G, H L plug connector: L, LN, LO Electrical entry M plug connector: M, MN, MO.5 W (With indicator light:.6 W): Series ZYY3 Power consumption.6 W (With indicator light:.65 W): Series ZYX3 Effective area (Cv factor) 4.68 mm 2 (.26) ZA ZX ZR ZM ZMA ZQ ZH ZU ZL ZY ZF ZP SP ZCUK AMJ AMV AEP HEP Related Equipment 185

Series ZYY/ZYX Electronic Vacuum Pressure Switch Specifications Model Sensor type Set pressure range Hysteresis Repeatability Temperature characteristics Operating voltage ZSE1 14 X129 ( X13) ZSE1 15 X129 ( X13) 1 to 1% of set pressure (Adjustable) ZSE1 16 X129 ( X13) ZSE1 17 X129 ( X13) ZSE1 18 X129 ( X13) Diffusion type semiconductor pressure sensor to 11 kpa 3% full span or less (Fixed) ±1% full span or less ±3% full span or less 12 to 24 VDC (Ripple ±1% or less) ZSE1 19 X129 ( X13) ZSE1 55 X129 ( X13) 1 to 1% of set pressure (Adjustable) ON-OFF output NPN open collector 3 V Max. 8 ma PNP open collector Max. 8 ma Analog output None 1 to 5V None Setting points 1 point 2 point 1 point Operation indicator light Lights up when ON (Red) Lights up when ON (OUT1: Red, OUT2: Green) Lights up when ON (Red) Setting trimmer rotation angle 3 turns 2 degrees 3 turns 2 degrees 3 turns 2 degrees 2 degrees Current consumption 17 ma or less (When 24 VDC is ON) 25 ma or less (When 24 VDC is ON) Max. operating pressure.2 MPa Note 1) When using an ejector, there is no problem if pressure of.5 MPa is applied for 1 second or less. Note 2) X129 is for Series ZYX3 and X13 is for Series ZYY3. 17 ma or less (When 24 VDC is ON) How to Order Electronic Vacuum Pressure Switch ZSE1 15 X 13 14 Output specifications Analog, no output, 3 turn setting Compatible model 129 For Series ZYX3 13 For Series ZYY3 15 16 17 18 Analog, no output, 2 degree setting NPN open collector, double output Analog, no output, 3 turn setting NPN open collector, double output Analog, no output, 2 degree setting Analog, with output, 3 turn setting Wiring specifications Grommet type L C CL Connector type CN Lead wire length.6 m Lead wire length 3 m Lead wire length.6 m Lead wire length 3 m Without connector 19 Analog, with output, 2 degree setting With connector/how to Order 55 PNP open collector, single output Analog, no output, 2 degree setting Without lead wires (1 connector and 4 sockets) With lead wires ZS-2-A ZS-2-5A- Note) When ordering a switch with 5 m lead wires, enter the part numbers for both a switch without connector and lead wires with connector. Lead wire length.6 m Example) ZSE1--15CN-X129 ZS-2-5A-5 1 pc. 1 pc. 3 5 3 m 5 m 186

Ejector Valve Unit Series ZYY/ZYX How to Set the Pressure How to Use the Connector Internal Circuit and Wiring Example The ON pressure is set with the pressure setting trimmer. High vacuum settings are obtained by turning it clockwise. When setting, use a flat head screw driver which fits the slot in the trimmer, and turn it gently with your finger tips. ZSE1- -14/-15/-18/-19 Hysteresis can be set using the hysteresis setting trimmer. The setting is increased by turning it clockwise, and the range is 1 to 1% of the ON pressure. When the hysteresis setting trimmer is moved after setting the ON pressure, it must be set again. Pressure setting trimmer Hysteresis setting trimmer Indicator light ZSE1- -16/-17 OUT1 (white lead wire, red LED) can be set with pressure setting trimmer 1 (SET1). OUT2 (green lead wire, green LED) can be set with pressure setting trimmer 2 (SET2). Pressure setting trimmer 1 Pressure setting trimmer 2 Indicator light SET HYS SET1 SET2 When using to confirm adsorption, set to the minimum vacuum pressure at which adsorption is possible. If set below this valve, the switch will turn ON even when adsorption has failed or is insufficient. Also take note that if the setting is too high, the switch may not turn ON even with good adsorption. 1. Attaching and detaching connectors To install the connector, hold the lever and connector unit between your fingers and insert it straight onto the pins. Then lock it by pressing the pawl of the lever into the slot on the housing. To remove the connector, pull it straight out while pressing the lever down with your thumb to release the pawl from the slot. Lead wire.2 to.33 mm 2 Max. covering dia. Socket ø1.7 mm Hook Connector DC polarity indication Lever 2. Crimping of lead wire and socket Strip 3.2 to 3.7 mm at the end of the wire, place the exposed core wire into the socket properly and crimp with a crimping tool. When this is done, be sure that the lead wire covering does not get into the core wire crimping area. (Crimping tool: Model DXT17-75-1) Core wire crimping area Socket Hook Covering 3. Attaching and detaching of socket to connector with lead wire Attaching Insert the sockets into the square holes of the connector (with +, 1, 2, indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires. Detaching To detach a socket from a connector, pull out the lead wire while pressing the socket s hook with a stick having a thin tip (about 1 mm). If the socket will be used again, first spread the hook outward. Socket Hook Lead wire Socket Connector.2 to.33 mm 2 Max. covering dia. ø1.7 mm DC polarity indication Lever Pin Slot Housing Covering retainer Core wire Lead wire Connector ZSE1- -14, -15 Main circuit of switch ZSE1- -16, -17 Main circuit of switch ZSE1- -18, -19 Main circuit of switch ZSE1- -55 Main circuit of switch Brown DC (+) OUT Black Load 3V, 8mA Blue DC ( ) Brown DC (+) (OUT1) Black Load 3V, 8mA (OUT2) White Load 3V, 8mA Blue DC ( ) Brown DC (+) (OUT1) Black Load 3V, 8mA Analog output White Load Blue DC ( ) Brown DC (+) (OUT1) Black Load 8mA Blue DC ( ) + 12 to 24 VDC + 12 to 24 VDC + 12 to 24 VDC + 12 to 24 VDC ZA ZX ZR ZM ZMA ZQ ZH ZU ZL ZY ZF ZP SP ZCUK AMJ AMV AEP HEP Related Equipment High vacuum Supply pressure Set pressure Reliable adsorption Unstable adsorption Hook Hysteresis Lead wire Hysteresis is the difference between the pressure at which the output signal turns ON and the pressure at which it turns OFF. It turns ON at the set pressure. Atmospheric pressure No adsorption High vacuum High pressure Set pressure Hysteresis ON OFF Atmospheric pressure 187

Series ZYY/ZYX Construction ZYY3 B B A A 11 1 4 5 3 12 13 Section A-A' (Ejector) 8 2 7 9 6 1 Section B-B' (Solenoid valve) Component Parts Replacement Parts No. Description Material Note No. Description Part no. 1 Manifold block Resin Urban white 9 3 port solenoid valve SY114-2 Body Zinc die-casted Urban white 1 ZSE1-- -X13 3 cover Resin Urban white 11 End plate assembly P4427A (Without a switch) 4 Nozzle Aluminum alloy 12 AN23-KM8 5 Diffuser Aluminum alloy 13 Non plug assembly ZYY3-NPA 6 Needle Stainless steel 7 Spool Aluminum alloy 8 Piston Resin 188

Ejector Valve Unit Series ZYY/ZYX Construction ZYX3 EXH. ZA B A 1 9 A B A P1 B 4 5 A B ZX ZR ZM ZMA 3 ZQ ZH ZU ZL ZY 12 Section A-A' (Ejector) 11 ZF ZP SP 2 7 ZCUK AMJ 8 AMV AEP HEP Related Equipment 6 1 Section B-B' (Solenoid valve) Component Parts Replacement Parts No. Description Material Note No. Description Part no. 1 Manifold block Resin Urban white 9 ZSE1-- -X129 2 Body Zinc die-casted Urban white 1 End plate assembly P44119A (Without a switch) 3 cover Resin Urban white 11 AN23-KM8 4 Nozzle Aluminum alloy 12 Plug assembly ZYY3-PA 5 Diffuser Aluminum alloy 6 Needle Stainless steel 7 Spool Aluminum alloy 8 Piston Resin 189

Series ZYY/ZYX Exhaust Characteristics/Flow Characteristics The flow rate characteristics correspond to a supply pressure of.45 MPa. Y3 ZY X3-7S ZY X3-7L Exhaust Characteristics Flow Characteristics Exhaust Characteristics Flow Characteristics -1 5-1 -1 5-1 Y3 Vacuum pressure Vacuum pressure (kpa) -8-6 -4-2 Air consumption Suction flow rate 4 3 2 1 Suction flow rate (l/min(anr)) Air consumption flow rate (l/min(anr)) Vacuum pressure (kpa) -8-6 -4-2 Vacuum pressure (kpa) -8-6 -4-2 Vacuum pressure 4 3 Air consumption 2 Suction flow rate 1 Suction flow rate (l/min(anr)) Air consumption flow rate (l/min(anr)) Vacuum pressure (kpa) -8-6 -4-2.1.2.3.4.5.6 1 2.1.2.3.4.5.6 5 1 15 2 25 Supply pressure (MPa) Suction flow rate (l/min(anr)) Supply pressure (MPa) Suction flow rate (l/min(anr)) Y3 ZY X3-1S ZY X3-1L Exhaust Characteristics Flow Characteristics Exhaust Characteristics Flow Characteristics -1-1 -1-1 Y3 Vacuum pressure (kpa) -8-6 -4-2 Vacuum pressure Air consumption Suction flow rate 6 4 2 Suction flow rate (l/min(anr)) Air consumption flow rate (l/min(anr)) Vacuum pressure (kpa) -8-6 -4-2 Vacuum pressure (kpa) -8-6 -4-2 Vacuum pressure 6 Air consumption 4 Suction flow rate 2 Suction flow rate (l/min(anr)) Air consumption flow rate (l/min(anr)) Vacuum pressure (kpa) -8-6 -4-2.1.2.3.4.5.6 5 1 15 2 25.1.2.3.4.5.6 1 2 3 4 5 Supply pressure (MPa) Suction flow rate (l/min(anr)) Supply pressure (MPa) Suction flow rate (l/min(anr)) How to Read Flow Characteristics Graph Vacuum pressure 19 Pmax P1 Q1 Suction flow rate Qmax The flow rate characteristics indicate the relationship between the vacuum pressure and the suction flow rate of the ejector, and show that when the suction flow rate changes the vacuum pressure also changes. In general, this indicates the relationship at the ejector, s standard operating pressure. In the graph, Pmax indicates the maximum vacuum pressure, and Qmax indicates the maximum suction flow rate. These are the values that are published as specifications in catalogs, etc. The methods for changing the vacuum pressure will be explained in order. 1. If the ejector s suction port is closed and sealed tight, the suction flow rate becomes and the vacuum pressure increases to the maximum (Pmax). 2. If the suction port is opened gradually and air is allowed to flow (the air leaks), the inlet flow rate increases and the vacuum pressure decreases. (the condition of P1 and Q1) 3. If the suction port is opened completely, the suction flow rate increases to the maximum (Qmax), while the vacuum pressure then drops almost to (atmospheric pressure). In this way, when the suction flow rate changes the vacuum pressure also changes. In other words, when there is no leakage at the vacuum port (vacuum piping), the vacuum pressure increases to the maximum, but the vacuum pressure drops as the amount of leakage increases, and when the amount of leakage and the maximum suction flow rate become equal, the vacuum pressure decreases nearly to. When adsorbing workpieces which are permeable or subject to leakage, etc., caution is required as the vacuum pressure will not be very high.

Ejector Valve Unit Series ZYY/ZYX Ejector Valve Dimensions ZYY3 LZ- 1-E C 49.4 41.6 (8.25) 1.4 43.1 (13.5) 58.6 Approx. 6 Manual override Pressure setting trimmer Manual override Button for block separation Indicator light (Red) Pilot valve for supply valve ZYY3 LZ- S1(Specifications without vacuum switch) 144 55.5 117 3.8 16.5 4 67 35.3 3 (Lead wire length) Pilot valve for release valve Manual override 28.5 33.6 62.1 43.1 Release flow rate adjusting needle Ejector unit Supply/Release valve Manual override 29.5 21 1 (5.25) 16.8 18.8 (33.3) 27 23.5 Release flow rate adjusting needle Circuit diagram V P1 Pilot valve exhaust port (M3: Port PE) (AN23-KM8) Vacuum port ø6 One-touch fitting (Port V ( Air pressure supply port ø6 One-touch fitting Port P1 ( ( ZA ZX ZR ZM ZMA ZQ ZH ZU ZL ZY ZF ZP SP ZCUK AMJ AMV AEP HEP Related Equipment End plate (P4427A) Manual override Manual override 55.5 117 16.5 3 (Lead wire length) 191

A A B EXH. P1 B Series ZYY/ZYX Ejector Valve Dimensions ZYY3 LZ- 1-E C-MN Ejector unit Supply/Release valve Release flow rate adjusting needle V Circuit diagram P1 V Hysteresis setting trimmer Pressure setting trimmer 28 1. (AN23-KM8 1 pc.) 51 26 ø16 15.8 8 28.5 25 Accessory (packed together) 2. Mounting bolt nut (M2 x.4 x 2 4 pcs.) 192

Ejector Valve Unit Series ZYY/ZYX Ejector Valve Dimensions ZYX3 LOZ- 1-E C Pressure setting trimmer Hysteresis setting trimmer 5 42 34 Manual override A side: Orange (for supply valve) B side: Green (for release valve) Button for block separation Approx. 6 14.2 Indicator light (Red) 1.8 (With indicator light and surge voltage suppressor) ZYX3 LOZ- S1(Specifications without vacuum switch) A B 88 EXH. 3.8 19 4 Release flow rate adjusting needle 57 62 Ejector unit Supply/Release valve 29.5 21 1 (5.25) 16.8 18.8 33.3 27 Circuit diagram 23.5 V Release flow rate adjusting needle (AN23-KM8) P1 Pilot valve exhaust port (M3: Port PE) Vacuum port ø6 One-touch fitting Port V Air pressure supply port ø6 One-touch fitting Port P1 ZA ZX ZR ZM ZMA ZQ ZH ZU ZL ZY ZF ZP SP ZCUK AMJ AMV AEP HEP Related Equipment End plate (P4427A) EXH. A B Manual override A side: Orange (for supply valve) B side: Green (for release valve) 1.8 193

Series ZYY/ZYX Ejector Valve Dimensions ZYX3 L- S-E C-F 3.8 6.7 Ejector unit V Supply/Release valve Release flow rate adjusting needle P1 Circuit diagram 18.8 (4) V Button for block separation -- + 8 ~ = 3 67 (19) 27 35 194

Ejector Valve Unit Series ZYY/ZYX Ejector Valve Dimensions ZYX3 L- S1-E C-FMN -+ - 19 13 9.6 85 Ejector unit Supply/Release valve 28.5 28.1 Circuit diagram 23.5 V Release flow rate adjusting needle P1 ZA ZX ZR ZM ZMA ZQ ZH ZU ZL ZY ZF ZP SP ZCUK AMJ AMV AEP HEP Related Equipment Accessory (packed together) 1. (AN23-KM8 1 pc) 51 26 ø16 2. Mounting bolt nut (M2 x.4 x 25 4 pcs.) 195

Series ZYY/ZYX Ejector Valve Dimensions ZYX3 L- S1-E C-MN Ejector unit Supply/Release valve V Release flow rate adjusting needle Circuit diagram P1 7.4 85 6.8 Accessory (packed together) 1. (AN23-KM8 1 pc) 51 26 ø16 2. Mounting bolt nut (M2 x.4 x 25 4 pcs.) 196

Ejector Valve Unit Series ZYY/ZYX Ejector Valve Dimensions ZYY3-PA (Plug-in assembly) 33.6 ZYY3-NPA (Non plug-in assembly) 33.6 16 86 33.3 27 33.3 27 ZA ZX ZR ZM ZMA ZQ ZH ZU ZL ZY ZF ZP SP ZCUK AMJ AMV AEP HEP Related Equipment 197

Series ZYY/ZYX Dimensions of DIN Rail Mounting Unit for ZYY3/ZYX3 Manifold The length of the standard accessory DIN rail is calculated with the formula below. Manifold overall length (L3) = (27 x Number of ejector valve stations) + (1.5 x Number of solenoid valve stations) + (16.5 x Number of supply/exhaust block stations) + C1 [mm] Note) In the case of ejector valves only (without solenoid valves), calculate the number of solenoid valve stations and supply/exhaust block stations as. Number of mounting holes (N) = (L3/12.5 + 1): Decimal fractions are truncated DIN rail overall length (L1) = N x 12.5 + 23 [mm] Mounting screw length (L2) = L1 1.5 [mm] Rail length on one side (L4) = (L1 L3)/2 [mm] C1 Value Selection Separate wiring type Connector box type D-sub connector 25 pin type Flat cable type Terminal block 9 pole type Terminal block 18 pole type Serial transmission type 45 A 45- NA 45F 45P 45T 45T1 45S 45S1 45S2 45S3 33 86 54 75 81.8 94.3 132 126 (mm) Stations U side Ejector valve End plate assembly L DIN rail r ewq D side Solenoid valve Supply/Exhaust block End plate assembly R L4 5.25 Indication example In the case of ZZYY3-45-4D-C6 SY314-5LZ SY324-5LZ SY334-5LZ ZYY35LZ-1S-E15C the dimensions are L1 = 135.5 mm L2 = 125 mm L3 = 18 mm L4 = 13.75 mm 8 5.5 16.5 16.5 27 16.5 1.5 L3 : Manifold overall length L2 : Mounting screw length L1 : Rail overall length 198

Series ZYY/ZYX Electronic Pressure Switches Specific Product Precautions 1 Be sure to read before handling. Warning Warning Design/Selection 1. Use with the specified voltage. Use with voltage outside of the specifications can cause malfunction or switch damage, as well as electrocution and fire hazard, etc. 2. Never use a load which exceeds the maximum load capacity. This may damage a switch or reduce its service life. 3. Do not use a load that generates surge voltage. Although a zener diode for surge protection is connected at the output side of a switch, damage may still occur if the surge is applied repeatedly. When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch having a built-in surge absorbing element. 4. Be sure to confirm the fluid specifications. Since switches do not have explosion-proof construction, do not use flammable gases or fluids. This may cause a fire or explosion. 5. Be certain to observe the regulating pressure range and maximum operating pressure. Operation at a pressure outside of this range can cause failure. In addition, the switch will be broken if operated above the maximum operating pressure. Mounting 1. Do not use until you can verify that equipment can operate properly. Verify correct mounting by suitable function and leakage inspections after air and power are connected following mounting, maintenance or conversions. 2. Do not drop or bump. Do not drop, bump or apply excessive impact (1 m/s 2 ) when handling. Even if the switch body is not damaged, the switch may suffer internal damage that will lead to malfunction. 3. Hold the product from the body side when handling. The tensile strength of the power cord is 49 N, and pulling it with a force greater than this can cause failure. Hold by the body when handling. 4. Turn the setting trimmer gently using a watchmakers screw driver. Turn the setting trimmer gently using a watchmakers screw driver. Do not turn beyond the stoppers located at both sides. If the trimmer is broken, adjustment will be impossible. 5. Pressure port Do not insert wire, etc, from the pressure port. This will damage the pressure sensor, making it impossible to obtain normal operation. Warning Wiring 1. Confirm wire colors and terminal numbers when wiring is performed. Since incorrect wiring can lead to breakage or failure of the switch as well as malfunction, perform wiring after confirming wiring colors and terminal numbers with the instruction manual. 2. Avoid repeatedly bending or stretching lead wires. Broken lead wires will result from applying bending stress or stretching force to the lead wires. In the event that lead wires are damaged creating a possibility of malfunction, replace the entire product. (For cases in which the lead wires cannot be replaced through grommets.) 3. Confirm proper insulation of wiring. Be certain that there is no faulty wiring insulation (contact with other circuits, ground fault, improper insulation between terminals, etc.). Damage may occur due to excess currect flow into a switch. 4. Do not wire power lines or high voltage lines. Wire separately from power lines or high voltage lines, avoiding pararell wiring or wiring in the same conduit with these lines. Control circuits, including switches, may malfunction due to noise from these other lines. 5. Do not allow short circuiting of loads. Use caution, as switches will be damaged instantly if a load is short circuited. Be especially careful not to reverse the power supply line (Brown) and the output line (Black). Pressure Source Warning 1. Observe the fluid and ambient temperature ranges. The fluid and ambient temperatures are 5 to 5 C. Moisture in circuits can freeze at 5 C or below, causing damage to O- rings, and malfunction. Consider measures to prevent freezing. The installation of an air dryer is recommended to remove drainage and moisture from circuits. Furthermore, even though the ambient temperature range remains within specifications, do not operate in locations where there are abrupt temperature changes. 2. Vacuum pressure switches There will be no change in performance if a pressure of.5 MPa or less is applied for 1 second or less (when releasing a vacuum), but care should be taken that pressures of.2 MPa or more are not regularly applied. ZA ZX ZR ZM ZMA ZQ ZH ZU ZL ZY ZF ZP SP ZCUK AMJ AMV AEP HEP Related Equipment 199

Series ZYY/ZYX Electronic Pressure Switches Specific Product Precautions 2 Be sure to read before handling. Warning Operating Environment 1. Never use in an atmosphere of explosive gases. The strucuture of pressure switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in locations with sources of surge generation. When equipment that generates a large amount of surge (solenoid type lifters, high frequency induction furnaces, motors, etc.) is located in the area around a pressure switch, thers is a danger of deterioration or damage to the switch s internal circuit elements. Therefore, implement surge countermeasures at the sources, and avoid the mixing and touching of lines. 3. Operating environment Since the electronic pressure switch is basically an open type, avoid use in locations where there is a scattering of water or oil, etc. Warning Maintenance 1. Perform maintenance regularly. It may otherwise not be possible to assure safety due to unexpected malfunction or misoperation, etc. 2. When used in an interlock circuit When used in an interlock circuit, provide multiple interlock circuits as a precaution against failure, and also perform regular inspections to confirm normal operation. 3. When the body requires cleaning Use a soft cloth to clean the case. In case of heavy soiling, wipe it off with a cloth soaked in a neutral detergent diluted with water after wringing it out thoroughly, and finish up by wiping with a dry cloth. Precautions Be sure to read before handling. Refer to front matters 38 and 39 for Safety Instructions and pages 844 to 846 for Vacuum Equipment Precautions. Caution Piping 1. Connect the compressed air supply piping separately to the solenoid valves and ejector valves. Also, connect each ejector valve to separate piping system. Operation of Ejector Valves Caution 1. When the pilot valve for air supply is turned ON, the main valve switches, and vacuum is generated by the flow of compressed air from the nozzle to the diffuser. When the pilot valve for vacuum release is turned ON, the main valve switches, and the vacuum is quickly released as air passes through the release flow adjustment needle and flows to the vacuum port. When the pilot valve for air supply and the pilot valve for vacuum release are both OFF, the main valve is in a closed state in the center position. Caution Operating Environment 1. Avoid use exposed to direct sunlight. Solenoid Valves (Series SY3/SX3) Caution 1. Refer to Best Pneumatics No. 1 and SMC, s website for Specific Product Precautions for solenoid valves (Series SY3/SX3). Caution Serial Wiring 1. Serial wiring is possible only for the solenoid valve section. Wire the vacuum switch separately. 11