Nexans Power Accessories. Bolted connectors

Similar documents
Mechanical Connectors, Lugs and Repair Sleeves for Medium Voltage Cable Accessories up to 42 kv

CONNECTORS AND FITTINGS

Nexans WINDLINK connection system. Nexans Power Accessories Germany GmbH

SICON. Connectors with Stepless Shear-Off Bolts. the power connection THE PFISTERER GROUP

MECHANICAL SHEAR-BOLT CONNECTORS A Best Fit Solution for Jointing Cable Conductors

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

Implementation of low inductive strip line concept for symmetric switching in a new high power module

Chapter 1. Connectors & Fittings for Railways

Power cable accessories catalogue

Around the cable. Socket sleeves.... convincing solutions

Power cable accessories catalogue

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

General information. General information

K Crimping dies HIS 13

High Voltage Accessories up to 72.5 kv

power cable accessories

TE S RAYCHEM RSTI-CC-58 SCREENED, SEPARABLE COUPLING SYSTEM

CONTENTS OVERHEAD SLEEVES AND LUGS

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

Electrical connection systems

026-2 : 1996 CEB STANDARD

K 22 HK 60/22 HK 60 UNV + UA22 EK 60/22 EKM 60/22

a Nexans company Medium voltage symmetrical separable connectors - Interface C -

(K),(M)430TB/G Up to 36 kv

a Nexans company Catalogue 2009

FLOODED (VLA ), SEALED (VRLA), GEL, AGM TYPE, FLAT PLATE, TUBULAR PLATE: THE WHEN, WHERE, AND WHY. HOW DOES THE END USER DECIDE ON THE BEST SOLUTION?

INTERFACE C MEDIUM VOLTAGE SYMMETRICAL SEPARABLE CONNECTORS CATALOGUE 2017

a Nexans company Catalogue 2008

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

Compression cable lugs and compression joints according to DIN

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

VP RP BP GP HALOGEN FREE INSULATED TERMINALS. P range funnel entry OPERATING TEMPERATURE UP TO 115 C

Insulation displacement terminals. OEC Product Catalogue

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

Nexans Network Solutions Div. Euromold

web:

Rehabilitation of Electricity Power Distribution Network in three areas in the Gaza strip (GS)

SUSPENSION 04 CLAMPS

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

THORNE & DERRICK UK TEL FAX TEL FAX

INTERFACE A MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

Shielded surge arresters

Connector Installation Guide Compression and Mechanical Connectors

WavePro LT Busway Cost effective solution for electrical distribution

Bonding & Grounding. Telecommunications Main Ground Bars. Telecommunications Main Ground Bar Kits

Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/

Cable systems We offer you the essential components for a future-oriented e-mobility.

(K),(M),(P)489TB/G Up to 42 kv

THORNE & DERRICK UK TEL FAX TEL FAX

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

a Nexans company Catalogue 2007

a Nexans company Catalogue 2009

The Sommerfeld number is also a dimensionless parameter used extensively in the design of

A-M COPPER TUBE CRIMPING LUGS. for copper conductors. A-M series lugs are manufactured

Unimate Range Pitch 5.08

a Nexans company Catalogue 2007

Nexans Network Solutions Div. Euromold

PRODUCT SHEET. Elastimold advanced connection system (shear bolt)

Nexans Network Solutions Div. Euromold

Product Range Modules ROSTA Tensioner Devices

Nexans Network Solutions Div. Euromold

S A F E & S U R E BETTER PRACTICES OF TERMINATION ON TO SWITCHGEAR

Medium voltage - Cable accessories up to 36 kv. Tapes Connection technique Tools

Component Specification

Special cables. Guarantee. Special cables

a Nexans company Catalogue 2009

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Electronic Circuit Breaker ESS20-0..

MR - MEDIUM RATING A

SPACERS AND SPACER DAMPERS

a Nexans company Catalogue 2015

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

The Separator arrangements depend on the application (see order example or separator options).

PRODUCT BROCHURE. Elastimold advanced connection system (shear bolt)

Item Code Description Unit Qty Total

a Nexans company Catalogue 2011

INTERFACE F MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

Cu-terminals and connectors mm²

Nexans Network Solutions Div. Euromold

Power cables accessories for use in potentially explosive atmospheres

Varius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

Wind turbines connecting solutions

a Nexans company Catalogue 2006

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

TOOLS FOR PROFESSIONALS ELECTROTECHNICAL PRODUCTS.

Transformer bushings, type GOA 250. Installation and maintenance guide

Fuel Oil Deaerator with Integrated Filter Type GS 2000

12-SDMS-02 REV. 05 ( )

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

GTV HVOF K2 Burner OPERATORS MANUAL GTV Verschleißschutz GmbH.

TIDALFLUX 2300 F Quick Start

3/ ABB cable accessories for PILC kv General accessories and Tools

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples.

Cu-terminals and connectors mm²

Product Specification Rev A

Power cable accessories catalogue

Installation and Operating Instructions for EAS -NC clutch Type 45_. _. _ Sizes 02 and 03

Low friction, low wear: The Fast and Slow Motion Specialist iglidur J

Transcription:

Nexans Power Accessories Bolted connectors 1

Summary 1. The function of bolted connectors The function Physical parameters Crimped versus bolted connectors Advantages of bolted connectors 2. Presentation of GHP connectors History of the screws Screw designs Multi shear level: screw of GPH Installation with cordless impact wrench Low voltage bolted connectors Medium voltage bolted connectors Tests according to EN 61238 High voltage screwed connectors Bimetallic contacts Split bolted contacts 3. Applications Requirements of EDF Examples 4. Conclusion 2

1. The function of bolted connectors 3

The function of bolted connectors Connecting of power cables or with other energy devices Low voltage, medium voltage and high voltage With conductor cross sections 6 300 630 1000 2000 2500 mm² The connection must transmit electrical energy - means high current - during the whole lifetime without negative influence on: the own function joints, terminations and plugs concerning their thermal, mechanical and insulation behaviour 4

Electrical Contact Quality Factor homogeneous conductor connectio n Rconductor Rconnecto quality factor k = r Rconductor R connector pretented contact area As mechanical suporting area At non conductive layer micro contacts electrical conductive area Aw Aw << As 5

Behaviour of the Electrical Contact Behaviour of the quality factor: k = Rconnector Rconductor quality factor k contact formation contact during life time accelerated ageing of the contact intermitting of the contact time t 6

Connector Resistance and Losses connector resistance Rconn The high rated currents I of the cable have to be carried by the connector during the whole life time. current I The temperature*) of the connection must be low to decrease the ageing of the contacts. That means that the losses P = I² * Rconn must be low. For that reason the connector resistance Rconn must be low. Iscrews current I conductor conductor Rscrews Rbody Ibody The connector resistance Rconn depends on: the resistance of the connector body and of the screws (material, shape) the contact resistance between conductor and connector body the contact resistance between conductor and screw tip the contact resistance between the wires of the conductor *) the temperature can be influenced by heat transfer due to conduction, radiation, convection (continuous current) and heat storage (short circuit current) 7

Effects on the Contact Resistance A low contact resistance Rconn between: conductor and connector body conductor and screw tip the wires of the conductor can be achieved by a high contact force F grooves to break non conductive layers and to generate a defined contact area contact resistance Mscrew conductor current path grooves F force F contact resistance [ ] material matching *) from: Böhme, H. : current *) conductor contact force Mittelspannungstechnik. Verlag Technik GmbH; Berlin, München,1992 contact shape Connector groove oxide layer force F contact force Fc [N] 8

Contact Resistance depending on the Screwing Moment screwing moment Mscrew connector resistance Rconn [µ ] contact force Fc connector resistance Rconn Measured resistance of different connectors Fscrew= Mscrew k 1 P + k 2 µ G d2 + k 3 µ S D diameter thread friction tip diameter pitch k1: 0,16 friction thread k : 0,58 2 k3: 0,5 Mscrew Fscrew thread tip screwing moment Mscrew [Nm] Fc 9

Contact Ageing The electrical resistance of a connection can be increased by: chemical ageing, means increasing of oxide layers and due to that constriction of micro contacts floating - espacially of aluminium conductors - and due to that reducing of the contact force Both effects will be accelerated at higher temperatures Because of that the electrical losses should be as small as possible 10

Crimped versus Bolted Connectors Compression connections crimping For every cross section a special crimp connector is needed. A copper conductor needs a copper connector. An aluminium conductor needs an aluminium connector. Bolted connections screwing Heavy tools and a lot of different dies are necessary Are range taking concerning conductor cross section for low and medium voltage application. Are adapted to the cross section range of the accessories. Copper and aluminium conductors, which could be round or sectoral shaped, stranded or solid, can be connected No special tools for the installation. 11

Advantages of Bolted Connectors Range taking concerning conductor cross section for low and medium voltage application Adapted to the cross section range of the accessories Copper and aluminium conductor Round, sectoral shaped Stranded, solid No special tools for the installation. 12

2. Presentation of the GHP connectors 13

History of Screw Development Development of bolted contacts since the eighties worldwide. 1. Headless screws (grub screw) with inner hexagon installation with a torque wrench which shows the required moment or depending on the intuition of the installer 2. Shear screws with one shear level predetermination of the right shear moment by the manufacturer usable for low voltage connectors / high voltage connectors 3. Multilevel shear screws for medium voltage application predetermination of the right shear moment regarding the cross section NPAG screw: biggest conductor with the biggest moment (contact force) screw shears off nearly flash with the surface of the connector no negative influence on the electrical field of the accessories 14

Design of Bolted Contacts/Screws depending on the Voltage Level Low Voltage - big excentricity and rel. big excess length after shear-off allowed - screws with 1-2 shear levels Medium Voltage -only small excentricity and small excess length after shear-off - screws with 2-4 shear levels High Voltage - round conductor channel especially adapted to the conductor - no excentricity - one shear level - high force screws for aluminium Milliken conductor with big cross section 15

Multi Shear Level Screw from NPAG The NPAG multi shear level screw is the only one on the market which has both main advantages. Installation with: allen key Biggest moment for the biggest cross section: means biggest contact force for the biggest conductor with the biggest nominal current Installation with standard keys which are commercially available hexagon socket Force Force During shear off the contact part of the screw will not be influenced (no constriction of the contact part). 16

Low Voltage Screwing Connectors 17

Low Voltage Screwing Connectors Screws with one (max. two) shear levels sectoral shaped or round conductor channel rel. big excentricity grooves cross and lengthwise piercing of solid conductors 18

Typical Low Voltage Screwing Connectors 416 MS-SV 6-16 4-16 6-16 SE1650 25-50 10-50 35-50 35-50 10-50 SE25150 35-150 25-50 35-120 25-95 25-95 35150 SV 35-150 35-50 35-120 35-95 35-95 25150 SV 25-150 25-50 35-120 25-95 25-95 SE25150SM 35-150 25-50 35-150 25-150 25-150 SE150300 150-300 / 150-300 150-300 150-300 19

Medium Voltage Screwing Connectors 20

Medium Voltage Screwing Connectors Screws with 2-4 shear levels, made of brass with tinned surface or made of aluminium alloy Connector body made of aluminium alloy Sectoral shaped or round conductor channel with small excentricity, with or without separating web, tinned surface Centering rings (plastic) Additional tinned tubes for very small cross section. 21

Typical Medium Voltage Screwing Connectors Al in mm2 rm(v) re Cu in mm2 rm(v) M16-95 16-95 16-95 10-95 M50-150 50-150 50-150 50-120 M70-240*) M95-240 70-240 95-240 70-240 95-240 70-240 95-240 MRL(T)95-240 95-240 95-240 95-185 M120-300 120-300 120-300 120-300 M185-400 M400-630 185-400 400-630 185-400 400-630 185-400 400-630 *) sectoral shaped conductor possible 22

Test according to EN 61238-1 Electrical test procedure 6 connectors have to be tested: 200 load cycles (median connector 100 C; reference conductor: 120 140 C) 6 short circuits (reference conductor: 250 270 C) 800 load cycles measuring of the resistance and of the temperature. Mechanical test procedure 3 connectors have to be tested: - tensile force F during 1 min no damaging or sliding 23

High Voltage Screwing Connector Screws with one shear level (up to 100.. 120 Nm) High force screws for Aluminium Milliken conductor Round conductor channel especially adapted to the conductor No excentricity Connecting parts up to 2000 (2500) mm² according to customer requirements 24

Connectors Electrical Contacts Electrical and mechanical requirements Transmission of electrical energy during the whole lifetime without negative influence on the own function joints, terminations and plugs concerning their thermal, mechanical and insulation behaviour Ensure the required tensile strength 25

Lean Bolted Connector M70 240 for round and sectoral shaped Al and Cu conductor Optimized fine thread for a big force and a high stability Integrated separation web against moisture and oil; absolutely leakproof because of machining Well defined grooves: very good electrical contact and mechanical behaviour 26

Copper Aluminium Parts Connecting of copper and aluminium by a very high force ideal electrical contact between both materials Manufacturing of cable lugs or other by forging and / or machining for an especially high current carrying capability 27

Floating of the conductor channel Stamp: manufactured by wire-electro discharge machining at NPAG Floating of the conductor channel by a stamp Machining afterwards pyramidal grooves 28

Split Bolt Connectors split screw with one shear level Available: 70 240 mm² 120 300 mm² 185 400 mm² split with grooves to reduce the electrical resistance Special shape for adjustment during connection of both parts Split Bolt Branch Connector according to customer requirements 29

3. Applications 30

Demand of EDF France EDF wants the introduction of bolted contacts for the whole range of the medium accessories: joints, terminations and connectors by 2010. All the accessoires need to pass the electrical qualification tests on the contacts (IEC 61238) and the products (Cenelec HD629.1 S1). The product redesign program is now half way. The joints, outdoor terminations and 400A connectors are already qualified. 31

Bolted Contacts for EDF EDF will change from deep indent to bolted contacts until 2010. >>> NPAG developed connectors and lugs for that reason. M70-240 connector 400A T-plug lug Indoor/outdoor lugs Branch connector For cross sections 70mm² - 240mm² round and sectoral shaped aluminium and copper conductors (50 mm² is possible by using tinned aluminium tubes) 250 A elbow and straight lug (with screwed copper PIN) for cross sections 35 95 mm² round stranded copper and aluminium conductor 32

Test of Bolted Contacts for EDF according to EN 61238-1 Electrical test procedure 6 connectors have to be tested. - 200 load cycles: median connector 100 C; reference conductor: 120 140 C - 6 short circuits: reference conductor: 250 270 C - 800 load cycles - measuring of the resistance and of the temperature Mechanical test procedure 3 connectors have to be tested. - tensile force F during 1 min no damaging or sliding 33

Test of Bolted Contacts for EDF according to EN 61238-1 Test arrangement 240 mm² aluminium round stranded reference conductor 400A T-plug lug 6 barrels Heating cycle with 800 A 34

Test of Bolted Contacts for EDF according to EN 61238-1 400 A T-plug lug 400A T-plug lug palm Barrel barrel Palm Barrel with 240 mm² aluminium round stranded 35

Test of Bolted Contacts for EDF according to EN 61238-1 Connector M 70-240 Electrical test with 240 mm² copper Tensile test with 240 mm² copper 36

Export of NPAG Products into around 50 Countries NPAG Hof (Germany) 37

4. Conclusion 38

Conclusion Bolted contacts are getting more and more the standard in advanced countries in electrotechnical applications. Nexans has with GPH the state of the art in the development of this product line. Special and customised designs are possible based on an in depth product knowledge. 39