Appendix ISO /03/05/07/08

Similar documents
Accessories. Subplates and Connection Plates for Four-Port Directional Valves. Vickers. ISO 4401, 02/03/05/07/08 General Description.

Directional Controls

Directional Controls

Proportional Valves. Proportional Two-Stage Directional Valves

Proportional Valves. Auxiliary Function Modules for Proportional Valves. Hydrostat, Parallel-Flow-Path, Pilot Shuttle and Tapping Modules

Solutions. Hydraulics. We Manufacture. H y d r a u l i c s. Vickers TM Proportional Directional Valves without Feedback. h y d r a u l i c s

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

Directional Controls

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description

Pressure Relief Valves

Servo-Performance Proportional Directional Valves with Feedback Pressures to 315 bar (4500 psi) KBSDG4V-5 1* Series

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Sepehr Hydraulic Asia

Directional Controls

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Functional Symbols and Application Notes

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

General specifications 3 5 Applications, features, and benefits 3 Specifications 4

Eaton Heavy Duty Hydrostatic Transmissions

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

EManually Operated Directional Valves

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

Directional Control Valves. General Description. Operation. Features

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

Char-Lynn HP 30 Motor

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Directional Control Valves. Features. Application. Operation

Vickers. Vane Pumps. V Series - Low Noise Vane Pumps High Performance Intravane Pumps For Industrial Applications.

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

D03 FluiDyne Valves. ENGINEERING DATA

Proportional Valves. Proportional Directional and Throttle Valves Solenoid Operated

DIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications

Eaton. Revised June, Heavy Duty Hydrostatic Transmissions. l r. Models 33 through 76 Hydrostatic Transmissions. We Manufacture.

Mounting and Assembly of Sandwich Bodies

PRESSURE SWITCH 1PS / 1PF / 1PT

Pilot Operated Directional Valves

Pilot Operated Directional Valves

Directional Controls

Directional Control Valves. General Description. Operation. Features

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

EMechanically Operated Directional Valves

These valves may be used to manually shift the spool position and change the direction of oil flow *2 1.8

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

General specifications 3 5 Applications, features, and benefits 3 Specifications 4

Directional Control Valves. General Description. Operation. Features

280 Series Stainless Steel Rotary Direction Control Valve For hydraulics in a harsh environment.

RELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled

Directional Control Valves

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

VALVES POWER TRANSMISSION T E C H N I C A L C A T A L O G

Directional Control Valves. Application. Features. Operation

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting

SM4-30 Servovalves Flows to 113 l/min (30 USgpm) Pressures to 140 bar (2000 psi)

SM4-10/12/15 Servovalves Flows to 57 l/min (15 USgpm) Pressures to 210 bar (3000 psi)

EManually Operated Directional Valves

9 Shaft type N = Metric, to DIN/ISO 3019, Part 2 and VDMA 24560, Part 1 Y = SAE models P*B5 to 15 only. Omit for 20 thru 90 models

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

Fixed Displacement Motor AA2FM (A2FM)

High Pressure, High Flow Rate Modular Valves

Electric Proportional Pressure Reducing Valves Series ERP 03.ERP

Eaton. Revised April, Directional Control Valves. Model 30540, 15 GPM Directional Control Valves. We Manufacture. Solutions

Sandwich Bodies TECHNICAL PRODUCT INFORMATION

Directional Controls

Model Model Model Model Back to Back. Medium Pressure Piston Pump Variable Displacement Closed Circuit

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

Vickers. Servo Valves. SM4-40 Servovalves. Flows to 151 l/min (40 USgpm) Pressures to 350 bar (5000 psi) Released 1/94

Directional Control Valves

DIRECT ACTING PRESSURE RELIEF VALVE Model : DPR

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Valves. Pilot Operated Directional Valves. Vickers. Service Data

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Char-Lynn Hydraulic Motors: h y d r a u l i c s

XCEL80 Steering Control Units

Motors & Pumps- Hydraulic Pumps, Motors & Power Units

Modular valves DO5 (NG 10) 315 bar

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188)

Directional Control Valves. Application. Features. Operation

Catalog PowrFlowTM PVX Vane Pumps

Service Data Vickers. Directional Controls. Pilot Operated Directional Control Valves DG5S4-10**-*-*-53 I-3624-S. Revised 9/1/86

CONTINENTAL HYDRAULICS VAD05M-VMD05M - AIR & LEVER OPERATED DIRECTIONAL VALVES

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor

High Pressure, Subplate Mounted Directional Control Valves

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Directional Controls

Directional Control Valves. Application. Features. Operation.

Size 06 (D03) Q max 100 l/min (26.4 GPM) p max 250 bar (4600 PSI) RPE*-06 PRM*-06

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

Solenoid Operated Directional Valve

Mobile Valves Proportional - Load Sensing

Product Tips and Features

Housings and Miscellaneous Parts

PowrFlow PVX Vane Pumps

FIXED DISPLACEMENT VANE PUMPS

whitedriveproducts SERIES Hydraulic Motor LIGHT DUTY

Transcription:

ppendix ISO4401 02/03/05/07/08

Fluid Recommendations Viscosity & Cleanliness Recommendation Minimum Optimum Maximum ISO Cleanliness 6.0 cst 20 43 cst 2158 cst 20/18/15 (45 SUS) (100-200 SUS) (10000 SUS) Introduction Hydraulic fluids are one of the vital components of hydraulic system. roper selection of oil assures satisfactory life and operation of system components. he purpose of this section is to provide readers with the knowledge required to select the appropriate fluids for use in systems that employ Eaton hydraulic components Viscosity and emperature Viscosity is the measure of a fluid s resistance to flow. he most important characteristics to consider when choosing a fluid to be used in a hydraulic system is viscosity. he fluid must be thin enough to flow easily but thick enough to maintain adequate lubricating film between components and to maintain proper sealing at the operating temperatures of the hydraulic system. For viscosity requirements, see table. Viscosity of any fluid is relative to temperature, as the fluid warms the viscosity decreases and vice versa. When choosing a fluid, it is important to consider the start-up and operating temperatures of the hydraulic system. high VI fluid shows relatively small change of viscosity with temperature. ubricants used for hydraulic applications may contain viscosity index improvers (VII). hey refer to these fluids as viscosity index improved or multiviscosity fluids. he viscosity of these fluids may drop down in use due to shearing ofvi improvers used in the formulations. nti-wear hydraulic oils containing polymeric thickeners, viscosity index improvers (VII) are generally used for wide band operating temperature applications hese fluids experience temporary and permanent viscosity loss during use in hydraulic system. Check the extent of viscosity loss (shear stability) to avoid hydraulic service below the recommended minimum viscosity. Oil with good shear stability is recommended for wide band temperature applications. Multi-grade engine oils, Fs, UOs, etc., also contain VIIs, and viscosity loss will be encountered during use. Cleanliness Cleanliness of the fluid in a hydraulic system is extremely important. More than 70% of all failures are caused by contamination Eaton recommends that the fluid used in its hydraulic components be maintained per ISO 4406. Cleanliness level requirements vary with the hydraulic components. he cleanliness of a hydraulic system is dictated by the cleanliness requirements of the most stringent component in the system. Cleanliness requirements for specific products are given in the table. OEM s and distributors who use Eaton hydraulic components in their hydraulic systems should provide these requirements in their designs. Contact Eaton filter representative for filtration information. Fluid Maintenance he condition of a fluid has a direct effect on the performance and reliability of the system. Maintaining proper fluid viscosity, cleanliness level, water content, and additive level is essential for excellent hydraulic system performance. Routine fluid condition monitoring is recommended. Fluid Selection remium grade anti-wear (W) petroleum based hydraulic fluids will provide the best performance with Eaton hydraulic components. ubricants that pass Eaton Vickers 35V25 high pressure vane pump test (Eaton S- 373 test procedure, SM specification D 6973) are considered good quality antiwear hydraulic fluids. utomotive crank case oils with merican etroleum Institute (I) letter designation SF, SG, SH, SJ, or higher per SE J 183 classes of oils are recommended for applications using Eaton DG valves utomotive crankcase oils generally exhibit less shear stability compared to industrial anti-wear hydraulic fluids, which can result in higher loss of viscosity during service life. Other mineral oil based lubricants commonly used in hydraulic systems are automatic transmission fluids (F) and universal tractor transmission oils (UO). Synthetic hydrocarbon base stocks, such as polyalphaolefins (O) are also used to formulate hydraulic fluids, engine oils, Fs and UOs lternate fluids are recommended when specific properties, such as fire resistance biodegradability etc., are necessary for the application. Keep in mind that alternative fluids may differ from W petroleum fluids in properties. dditional Notes When choosing a hydraulic fluid, all the components in the system must be considered. Viscosity limitations has to meet the most stringent component requirements. For any system where the fluid is non-petroleum oil, set the target one ISO code cleaner for each particle size, than that of petroleum fluids. Keep adequate fluid level in the reservoir. ake fluid level reading when the system is cold. For more details, refer to Eaton Fluid Recommendation Document # 03-401-2010. Contact your Eaton representative, if you have specific questions about the fluid requirements of Eaton hydraulic components. -2 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

abulation of bolt kits and seal kits Direction control single stage I Size 2 (D02) olt kit (metric) Seal kit Seal kit comments DG4V-2 DG2V-2 DG17V-2 DG21V-2 02-156493 02-156492 II Size 3 (D03) olt kit (metric) Seal kit Seal kit comments 858996 Seal kit for DG4V 360 din 858996 Seal kit for DG4V 360 flying lead DG4V3-60 02-414945 Seal kit for F6-DG4V3(S)-60 02-398366 Seal kit - DG4V-3M-*-60 02-398367 Seal kit - F6-DG4V- 3M-*-60 859049 Soft shift seal kit DG4V3-70 616452 02-397447 F3 02-397448 F6 DG3/4V-3 992686 Nitrile 992758 Viton (F3) DG3V-3 02-110959 DG17V-3 696877 DG18V-3 696925 DG20V-3 920324 III. Size 5 (D05) olt kit (metric) Seal kit Seal kit comments DG4V5 459057 C 466310 459058 DC Direction Control wo stage I. Size 5 (D05) olt kit (metric) Seal kit Seal kit comments DG3V-5/ 466310 02-156844 DG5V-5 II. Size 7 (D07) olt kit (metric) Seal kit Seal kit comments DG3V-7/ DG5V-7 858918 III. Size 8 (D08) olt kit (metric) Seal kit Seal kit comments DG3V-8/ DG5V-8 255655 02-329888 SNDRD 10 Design 02-329889 F3 IV. Size 10 (D10) olt kit (metric) Seal kit Seal kit comments DG3V-10/ DG5V-10 461580 02-329888 SNDRD 10 Design 02-329889 F3 Direction Control Stak Valves I. Size 2 (D02) olt kit (metric) Seal kit Seal kit comments DGMC-2 02-157032 DGMR-2 02-157033 DGMR1-2 02-157033 DGMX2-2 02-157033 DGMC-2 Not available 02-157030 DGMDC-2 02-157030 DGMFG-2 02-157031 DGMFN-2 02-157031 DGMFD-2 02-157031 II. Size 3 (D03) olt kit (metric) Seal kit Seal kit comments DGMC-3 870737 DGMR-3 870739 DGMR1-3 870739 DGMX-3 Not available 870737 DGMDC-3 870708 DGMC-3 870708 DGMFN-3 870707 III. Size 5 (D05) olt kit (metric) Seal kit Seal kit comments DGMC-5 978463 DGMR-5 978464 DGMR1-5 978464 DGMX2-5 Not available 978464 DGMDC-5 978466 DGMC-5 978465 DGMFN-5 639407 EON Industrial Valve Catalog E-VVI-SS001-E October 2016-3

Subplates and Connection lates for Four-ort Directional Valves ISO 4401, 02/03/05/07/08 General Description his range of subplates and auxiliary connection plates offers an economical way of mounting the range of Vickers directional control valves and associated stackable auxiliary valves. Size 02 he 2 to 6 multi-station subplates, available on sizes 02 and 03 provide very compact control assemblies when used together with Vickers SystemStakM valves. Size 03 he varied maximum pressure ratings of this current range of subplates, etc., are clearly indicated in the Schedule of lates and Subplates for each size. lates having machined O-seal recesses are supplied complete with O-seals. ll Vickers 02 and 03 valves and auxiliary plates are fitted with a location pin to ensure correct orientation of the mounting surfaces. When a subplate is not used, a machined pad must be provided for the valve mounting. his pad must be flat within 0,01 mm per 100 mm (0.0001 per 1 ) and smooth within 0,8 μm (32 μn), over the area designated in the appropriate ISO 4401 standard. Size 02 Size 05 Size 07 X Size 08 X Size 10-4 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

able of Contents Size 02 Description and Mass kg (lb) Functional Symbol Model Code Max. ressure DGM-2--1* DGM-2-C1-1* DGM-2-C2-1* DGM-2-1-1*-R DGM-2-1-1*-S DGM-2-2-1*-R DGM-2-2-1*-S DGOM-2-1*-R DGM-2-4-10-R DGM-2-4-10-S DGM-2-3-1*-R DGM-2-3-1*-S DGMS-2-1E-1*-R DGMS-2-1E-1*-S DGMS-2-2E-1*-R DGMS-2-2E-1*-S DGMS-2-3E-1*-R DGMS-2-3E-1*-S DGMS-2-4E-1*-R DGMS-2-4E-1*-S DGMS-2-5E-1*-R DGMS-2-5E-1*-S DGMS-2-6E-1*-R DGMS-2-6E-1*-S Mounting Surface to ISO 4401 lanking plate Cast iron 0,24 (0.53) Crossover plate -; - Cast iron 0,21 (0.46) Crossover plate -; - Cast iron 0,21 (0.46) apping plate, ports and Cast iron 0,28 (0.62) apping plate, ports and Cast iron 0,28 (0.62) Orifice plate Cast iron 0,12 (0.27) daptor plate, DG4M4 to size 02 Cast iron 0,6 (1.2) daptor plate, size 03 to 02 Cast iron 0,43 (0.95) Single-station subplate; side ports,,, luminium 0,13 (0.29) Size 2 DG4M4 Size 2 Size 3 Multi-station subplate/manifold; side ports,, 1, 1, 2, 2, etc. 2-station luminium 1,36 (3.0) 3-station luminium 1,85 (4.1) Valve station 1 Valve stations 2-3 1 1 2 2 1 1 2 2 1 1 Multi-station subplate/manifold; side ports,, 1, 1, 2, 2, etc. 4-station luminium 2,36 (5.2) 5-station luminium 2,87 (6.3) 6-station luminium 3,37 (7.4) 2 2 Valve station 1 Valve stations 2-6 1 1 6 6 1 1 6 6 1 1 6 6 * Design number subject to change. No change of installation dimensions for design numbers 10 to 19 or 21 to 29 inclusive. S suffix = SE/UNC ports and/or UNC fixing bolt tappings and/or orifice plugs as appropriate. R = ISO 228 (SF) ports and/or metric fixing bolt tappings and/or orifice plugs as appropriate. EON Industrial Valve Catalog E-VVI-SS001-E October 2016-5

able of Contents Size 03 Description and Mass kg (lb) Functional Symbol Model Code Max. ressure DGM-3--1* DGM-3-C1-1* DGM-3-C2-1 * DGM-3-1-1*- DGM-3-1-2*-S DGM-3-2-1*- DGM-3-2-2*-S DGVM-3-1*-R DGVM-3-1*-S KDGVM-3-1*-R KDGVM-3-676803-1 (SE/UNF ports) DGMS-3-1E-1*-R DGMS-3-1E()-1*-S DGM-3-01-1*-R DGM-3-01-1* (UNC valve mounting bolts) DGMS-3-2E-1*-R DGMS-3-2E(X)-1*-S DGMS-3-3E-1*-R DGMS-3-3E(X)-1*-S DGMS-3-4E-1*-R DGMS-3-4E-1*-S DGMS-3-5E-1*-R DGMS-3-5E-1*-S DGMS-3-6E-1*-R DGMS-3-6E-1*-S Mounting Surface to ISO 4401 lanking plate Cast iron 0,5 (1.1) Crossover plate -; - Cast iron 0,5 (1.1) Crossover plate -; - Cast iron 0,5 (1.1) apping plate, ports and Cast iron 0,5 (1.1) apping plate, ports and Cast iron 0,5 (1.1) Single-station subplate; rear ports,,, Cast iron 1,3 (2.9) Single-station subplate; rear ports,,, ; side port Cast iron 1,3 (2.9) Single-station subplate; side ports,,, Cast iron 1,3 (2.9) daptor, size 05 to 03 Cast iron 0,6 (1.3) Multi-station subplate/manifold; side ports,, 1, 1, 2, 2, etc. 2-station Cast iron 4,0 (8.8) 3-station Cast iron 5,5 (12.1) Size 03 Size 05 Valve station 1 Valve station 2 1 1 1 1 2 2 2 2 1 1 u u 2 2 u hrough-connection and ports on types DGMS-3-2EX-1*-* and DGMS-3-3EX-1-*. Multi-station subplate/manifold; side ports,, 1, 1, 2, 2, etc. 4-station Cast iron 7,0 (15.4) 5-station Cast iron 8,5 (18.7) 6-station Cast iron 10,0 (22.0) Valve station 1 Valve station 6 1 1 1 1 6 6 6 6 1 1 6 6 *Design number subject to change. No change of installation dimensions for design numbers 10 to 19 or 21 to 29 inclusive. S suffix = SE/UNC ports and/or UNC fixing bolt tappings and/or orifice plugs as appropriate. R or = ISO 228 (SF) ports and/or metric fixing bolt tappings and/or orifice plugs as appropriate. -6 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

able of Contents Size 05 Description and Mass kg (lb) Functional Symbol Model Code Max. ressure DGM-5--1* 315 bar (4500 psi) DGM-5-C1-1* 315 bar (4500 psi) DGM-5-C2-1* 315 bar (4500 psi) DGM-5-1-1*- 315 bar (4500 psi) DGM-5-2-1*- 315 bar (4500 psi) DGM-5-3-1*- 315 bar (4500 psi) DGM-5-1*-R DGM-5-1*-S 210 bar (3000 psi) DGSM-01-2*-8 210 bar (3000 psi) DGSME-01-2*-8 EDGSM-01-1*-R EDGSM-01X-1*-R EDGSM-01-1*-R 210 bar (3000 psi) 280 bar (4000 psi) KDGSM-5-676805-2* (SE/UNF ports) KDGSM-5-615225-1* (1 2 SF ports) KDGSM-5-615226-1* (3 4 SF ports) 210 bar (3000 psi) Mounting Surface to ISO 4401 lanking plate Cast iron 2,9 (6.4) Crossover plate -; - Cast iron 2,9 (6.4) Crossover plate -; - Cast iron 2,9 (6.4) apping plate, ports and Cast iron 0,5 (1.1) apping plate, ports and Cast iron 0,5 (1.1) apping plate, ports, and Cast iron 0,5 (1.1) daptor plate for pilot ports X and Cast iron 1,4 (3.1) X Single-station subplate; side ports,,, Cast iron 2,0 (4.4) Single-station subplate; rear ports,,, Cast iron 2,0 (4.4) Single-station subplate; rear ports,,, ; and port (side or rear) Cast iron 1,3 (2.9) Single-station subplate; rear ports,,, plus X and Cast iron 2,0 (4.4) X 315 bar (4500 psi) 280 bar (4000 psi) EKDGSM-01-1*-R EDGSM-03-1*-R EDGSM-03X-1*-R EDGSM-03X-1*-S 210 bar (3000 psi) * Design number subject to change. No change of installation dimensions for design numbers 10 to 19 or 21 to 29 inclusive. S or 8 suffix = SE/UNC ports and/or UNC fixing bolt tappings and/or orifice plugs as appropriate. R or = ISO 228 (SF) ports and/or metric fixing bolt tappings and/or orifice plugs as appropriate. EON Industrial Valve Catalog E-VVI-SS001-E October 2016-7

able of Contents sizes 07 and 08 Description and Mass kg (lb) Functional Symbol Model Code Max. ressure Mounting Surface to ISO 4401 Single-station subplate Cast iron 3,8 (8.4) Cast iron 3,8 (8.4) Cast iron 6,1 (13.4) Cast iron 5,0 (11) Cast iron 5,0 (11) Cast iron 13 (28.6) X DGSM-04 EDGVM-7X EDGVM-7/7Z DGSM-8 EDGVM-8X EDGVM-8/8Z 210 bar (3000 psi) 350 bar (5000 psi) 350 bar (5000 psi) 210 bar (3000 psi) 350 bar (5000 psi) 350 bar (5000 psi) Operating Data Maximum flow rates Hydraulic fluids emperature limits Mounting attitude No functional limitations: dependent on valves used Compatible with all fluids recommended for Vickers sizes 02, 03, 05, 07, and 08 valves s for valves, subject to limits: 20oC to 70oC ( 4oF to 158oF) No restrictions, other than for valves fitted olt Kits for Mounting Valves Valve Size olt hreads Metric Inch orque (threads lubricated) 02 03 05 07 08 10 M5-6H M5-6H M6-16H M10 M6 M12-6H M20 #10-24 UNC-2 #10-24 UNC-2 1 4-20 UNC-2 3 8-16 UNC-2 1 4-20 UNC-2 1 2-13 UNC-2 3/4-10 UNC-2 5-7 Nm (44-62 lbf in) 7-9 Nm (62-79 lbf in) 9-14 Nm (7-10 Ib.ft.) 49-59 Nm (36-44 Ib.ft) 9-14 Nm (7-10 Ib.ft.) 103-127 Nm (79-94 Ib.ft.) 367-447 Nm (270-330 lb.ft.) Note: If not using Vickers recommended bolt kits, bolts used should be to ISO 898 class 12.9 or better. Use lower torque figures only when specified, e.g. for valves with lower maximum pressure rating. olt extenders available for use with size 05 valves cannot be used with size 05 auxiliary plates featured in this catalog. -8 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Mounting surfaces to ISO 4401 (size 02) Dimensional olerances Dimensional tolerance on interface drawings is ± 0,2 mm (± 0.008 ) except where otherwise stated. ISO 4401 specifies inch conversion to ± 0.01. Conversion from Metric ISO 4401 gives dimensions in mm. Inch conversions are accurate to 0.01 unless otherwise stated. Mounting olt appings ISO 4401 gives metric thread tappings. lternative UNC tappings are Vickers recommendations that allow these plates and associated valves to be used up to their recommended maximum pressures, when using Vickers recommended mounting bolt kits, or bolts of an equivalent strength (see catalog 2314 Fixing olt Kits ). It is recommended that Customer s own manifold blocks for UNC bolts should be tapped to the minimum depths given in the footnotes. Vickers Standard Size 02 Interface his interface conforms to ISO 4401-02-01-0-94 50,1 (1. 97) min. 26,5 (1.04) 24,0 (0.95) 19,7 (0.78) 12, 0 (0.47) 2,25 (0.09) 4,3 (0.17) 0,75 (0.03) 22,5 (0.88) 20,25 (0.8) 17,75 (0.7) 11,25 (0.44) 23,25 (0.92) 35,2 (1.39) min. 37,5 (1.48) min. 4 holes, see table for thread options 4 ports Ø 4,75/4,90 (0.187/0.193 dia) Ø 3,40/3,55 x 4,3 deep (0.134/0.140 dia x 0.17 deep) for locating pin Mounting olt apping Options hread Metric M5-6H Inch #10-24 UNC-2 Min. tapping depth for subplates/manifolds in Steel Cast iron 12,3 (0.484) 12,3 (0.484) 12,6 (0.496) 14,9 (0.587) luminium 12,3 (0.484) 14,9 (0.587) Note: his dimension gives the minimum space required for a valve with this mounting surface. he dimension is also the minimum center-to-center pitch of mounting surfaces on a manifold block. EON Industrial Valve Catalog E-VVI-SS001-E October 2016-9

Mounting surfaces to ISO 4401 (size 02) DGM-2--1* lanking late 3rd angle projection Ø 5,75 (0.226 dia.) 20,0 (0.78) 10,0 (0.39) 37,0 (1.46) 35,0 (1.38) Ø 9,0 (0.354 dia.) 50,0 Ø 3,0 (1.97) (0.12 dia.) Nameplate 3,0 (0.12) DGM-2-C*-1* Crossover late Ø 5,75 (0.226 dia.) 20,0 (0.78) 10,0 (0.39) 37,0 (1.46) 35,0 (1.38) Ø 9,0 (0.354 dia.) 50,0 (1.97) Ø3, 0 (0.12 dia.) Nameplate 3,0 (0.12) DGM-2-C1-1* (-, -) DGM-2-C2-1* (-, -) -10 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Mounting surfaces to ISO 4401 (size 02) DGM-2-*-1*-* apping lates 20,0 (0.78) 2 tapped ports for DGM-2-*-1* -R, G 1 / 8 ( 1 / 8 SF) for DGM-2-*-1* -S, 7 / 16 20 UNF-2 (SE) (for 1 / 4 O.D. tubing) 37,0 (1.46) 35,0 (1.38) 0, 5 (0.02) Ø 3, 0 (0.12 dia.) 60,0 (2.36) 50,0 (1.97) Nameplate 3,0 (0.12) 0,5 (0.02 ) 25,0 (0.98) DGM-2-1-1*-* (orts and ) DGM-2-2-1*-* (orts and ) DGOM-2-1*-R Orifice late ort Restrictor lugs Ø 5,5 (0.216 dia.) 20,0 (0.78) 8,0 (0.31) 37,0 (1.46) 35,0 (1.38) Restrictor plugs are available for use inports,, and. hese can be used for restricting flow or for circuit dampening. Restrictor plugs are not recommended for use above 210 bar (3000 psi) system pressure. 50,0 (1.97) M5 x 0,8-6H Code Orifice diameter art number *00 lank 977935 9,0 (0.35) Ø 3,0 (0.12 dia.) 3,0 (0.12) *05 0,5 (0.02) 977936 *06 0,6 (0.024) 977937 *08 0,8 (0.030) 986031 *10 1,0 (0.040) 986032 *12 1,2 (0.047) 977940 *15 1,5 (0.060) 986033 *18 1,8 (0.071) 872451 *20 2,0 (0.080) 479088 *23 2,3 (0.090) 977943 *,, or as required. vailable in multiples of 25 per part number. EON Industrial Valve Catalog E-VVI-SS001-E October 2016-11

Mounting surfaces to ISO 4401 (size 02) ISO 02 daptor late DGM-2-4-10-R DGM-2-4-10-S When replacing a DG4M4, this adaptor plate has been designed in line with our range of subplates and auxiliary plates. wo versions are offered: S SE-UNC ports and/or UNC attaching bolt tappings and/or orifice plugs. R ISO 228 (SF) ports and/or metric attaching bolt tappings and/or orifice plugs. 24,0 (0.94) 10,5 (0.41) 27,0 (1.06) 10,0 (0.39) 51,0 (2.00) 34,95 (1.37) 6,75 (0.26) 24,0 (0.94) 9,3 (0.37) 28,5 (1.12) 58,0 (2.28) 22,5 (0.88) Centerline of DG4V2 valve Centerline of DG4M4 valve -12 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Mounting surfaces to ISO 4401 (size 02) DGM-2-3-1*-R (Metric olt appings) DGM-2-3-1*-S (UNC olt appings) daptor late, Size 03 to 02 For pressures up to Size 02 valves can frequently be used in place of size 03 valves, or generally where the system flow rate is within that of size 02 valves. he DGM-2 adaptor plate bolts to an existing size 03 interface and provides a size 02 mounting face for the smaller valve. Size 2 Size 3 0.75 (0.03) 46,0 (1.81) 23,25 (0.92) 4,25 (0.17) 23,0 (0.9) 10,0 (0.39) 48,0 (1.9) 32,5 (1.279) 6,75 (0.26) 60,0 (2.36) 7,0 (0.28) 24,0 (0.95) Ø 10,0 (0.39 dia.) Ø5,75 (0.226 dia.) 9,75 (0.38) 40,5 (1.59) 22, 5 (0.88) 4 holes for valve mounting bolts (see table) 0,75 (0.03) 31,0 (1.22) Size 02 Mounting Face Size 03 Mounting Face (ISO 4401 Size 03) Model DGM-2-3-1*-R DGM-2-3-1*-S Valve mounting bolt tappings M5 x 12,3 (0.48) deep #10-24 UNC x 14,9 (0.587) deep DGMS-2-1E-1*-* Single-Station Subplate, Side apped orts 34,5 (1.36) 20,0 (0.78) 6,5 (0.26) Ø10,0 (0.39 dia.) 75,0 (2.95) 62,0 (2.44) 6,5 (0.26) Ø 5,7 5 (0.226 dia.) 62,0 (2.44) 75,0 (2.95) Model cod e stamped here 18,5 (0.73) Model orts,,, tappings Valve mounting bolt tappings DGM-2-3-1*-R G3 8 (3 8 SF) x M5 x 12,3 (0.48) deep 12,0 (0.47) deep DGM-2-3-1*-S 3 4 16 UNF-2 x 14,3 (0.56) deep #10-24 UNC x 14,9 (0.587) deep 4 holes for valve mounting bolts (see table) 4 ports (see table) EON Industrial Valve Catalog E-VVI-SS001-E October 2016-13

Mounting surfaces to ISO 4401 (size 02) DGMS-2-*E-1*-* Multi-Station Subplates (4-station model illustrated) Valve Station 1 1 1 1 1 1 1 Valve Stations 2-3 2 2 2 2 2 2 Valve Station 1 Valve Stations 2-6 1 1 1 1 6 6 6 6 1 1 6 6 74,5 (2.93) Ø 5,75 (0.226 dia. thru) 75,0 (2.95) 37,5 (1.47) 37,5 (1.47) 37,5 (1.47) 37,5 (1.47) 32,8 (1.29) Ø10,0 (0.39 dia.) 34,5 (1.36) 20,25 (0.8) 60,0 (2.36) 20,0 (0.78) 37,5 (1.47) 6,0 (0.24) 37,5 (1.47) 2 ports and on all models, tapped per model code, (see table 2) 4 holes per station for valve mounting bolts, tapped per model code (see table 3) 2 ports, and through drilled end-to-end, tapped per model code (see table 2) and ports at each station, tapped per model code (see table 2) 17,25 (0,68) 2 holes for attaching bolts, tapped per model type (see table 3) Model code stamped here 40,0 (1.57) able 1: Dimensions Model DGMS-2-2E-1*-* DGMS-2-3E-1*-* DGMS-2-4E-1*-* DGMS-2-5E-1*-* DGMS-2-6E-1*-* 102 (4.02) 140 (5.5) 178 (7.0) 216 (8.5) 254 (10.0) 90 (3.54) 125 (4.92) 165 (6.5) 200 (7.9) 240 (9.45) able 3: Mounting olt appings Model Valve mounting bolts Manifold rear-mount holes DGMS-2-1E-1*-R M5 x 12,3 (0.48) deep M8 x 1,25-6H DGMS-2-1E-1*-S #10-24 UNC x 14,9 deep 5 16-18 UNC-2 able 2: ort appings Model orts, orts, DGMS-2-1E-1*-R G1 2 (1 2 SF) G3 8 (3 8 SF) x 12,0 (0.47) deep DGMS-2-1E-1*-S 3 4-16 UNF-2 3 4-16 UNF-2 x 14,3 (0.56) deep -14 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Mounting surfaces to ISO 4401 (size 03) Vickers Standard Size 03 Interface his interface conforms to: ISO 4401-03-02-0-94 plus location pin hole NSI/93.7M (and NF) size 03 CEO R35H4.2-4-03, plus location pin hole DIN 24340 Form 6 plus location pin hole 4 holes, M5-6H x 12 (0.47) min. full thread depth 30,2 (1.18) 21,5 (0.85) 12,7 (0.5) 0,75 0,1 (0.03 0.004) 15,5 (0.61) 25,9 (1.01) 31,0 0,1 (1.22 0.004) 4 ports Ø 6,3 (0.25 dia). For all Vickers size 03 valves this diameter may be increased to Ø 7,5 (0.29) Ø 4,0 x 4,3 min. depth (0.16 dia x 0.17) for locating pin 5,1 (0.20) 70 (2.75) min. 31,75 0,1 (1.25 0.004) 7,5 (0.29) 40,5 0,1 (1.59 0.004) 48 (1.89) min. #10-24 UNC-2 optional. Interface with dditional Drain ort he interface conforms to Vickers standard, plus hole ypically used for proportional and other valves requiring an additional drain port, e.g.: KFDG4V-3 KFG4V-3 KSDG4V-3 25,3 (0.99) 46,5 (1.83) Ø4,0 (0.16 dia) EON Industrial Valve Catalog E-VVI-SS001-E October 2016-15

Mounting surfaces to ISO 4401 (size 03) DGM-3--1* lanking late 10,0 (0.4) 73,0 (2.9) Nameplate 46,0 (1.8) 22,0 (0.9) 24,4 (1.0) DGM-3-C*-1* Crossover late he sealing faces shown are for 11-design. For 10-design the sealing face is the same as for DGM-3--1* (transfer passages are drilled). Ensure correct design number is quoted when ordering spare seals. 4 holes Ø 5,6 (0.22 dia) counterbored to Ø9,5 (0.374 dia) 10,0 (0.4) 75,0 (3.0) 46,0 (1.8) 48,5 (1.9) Nameplate 22,0 (0.9) DGM-3-C1-1* DGM-3-C2-1* -16 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Mounting surfaces to ISO 4401 (size 03) DGM-3-1-**-1* apping late, orts and 4 holes Ø5,6 (0.22 dia) 2 tapped ports: For DGM-3-1-1*-, G1/8 ( 1/8 SF) For DGM-3-1-2*S, 7/16-20 UNF-2 (SE) (for 1/4 O.D. tubing) 75,0 (3.0) Nameplate 46,0 (1.8) 48,4 (1.9) 20,0 (0.78) DGM-3-2-**-1* apping late, orts and 4 holes Ø5,6 (0.22 dia) 2 tapped ports: For DGM-3-2-1*-, G1/8 ( 1/8 SF) For DGM-3-2-2*-S, 7/16-20 UNF-2 (SE) (for 1/4 O.D. tubing) 75,0 (3.0) Nameplate 46,0 (1.8) 48,4 (1.9) 20,0 (0.78) EON Industrial Valve Catalog E-VVI-SS001-E October 2016-17

Mounting surfaces to ISO 4401 (size 03) Single-Station Subplates, Rear and Side apped orts 4 holes Ø5,6 (0.22 dia) spotfaced to Ø 13,0 (0.51 dia) 4 system connections for rear-entry models, see table 4 system connections for side-entry models, see table 35,0 (1.38) 84,0 (3.3) 20,0 (0.79) 57,25 (2.25) 35,0 (1.38) 12,75 (0.5) 12,75 (0.5) 36,0 (1.42) 59,25 (2.33) 16,3 (0.64) Rear mounting face 16,0 (0.63) ort (see KDGVM-3 models in tables) 72,0 (2.83) 15,75 (0.62) 19,75 (0.78) 6,0 (0.24) 72,0 (2.83) 6,0 (0.24) 84,0 (3.3) 4 holes tapped according to model type (see table): For models with SF ports, M5-6H x 12 (0.47) deep For models with SE ports, #10-24 UNC-2 x 12,7 (0.5) deep ort hreads Model SF ports/m5 mounting bolts: DGVM-3-1*-R KDGVM-3-1*-R DGMS-3-1E-1*-R orts,,, t rear or side Rear Rear Side G3 8 (3 8 SF) x 12,0 (0.47) deep G3 8 (3 8 SF) x 12,0 (0.47) deep G3 8 (3 8 SF) x 12,0 (0.47) deep orts _ G1 8 (1 8 SF) x 12,0 (0.47) deep _ SE ports/#10-24 UNC mounting bolts: DGVM-3-1*-S KDGVM-3-676803-1* DGMS-3-1E-1*-S DGMS-3-1E-1*-S Rear Rear Side Side 3 4-16 UNF-2 x 14,3 (0.56) deep (SE) 3 4-16 UNF-2 x 14,3 (0.56) deep (SE) 3 4-16 UNF-2 x 14,3 (0.56) deep (SE) 5 8-18 UNF-2 x 12,7 (0.5) deep (SE) _ 7 16-20 UNF-2 x 11,6 (0.46) deep (SE) s 11,5 (0.45) from rear mounting face to port center line. -18 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Mounting surfaces to ISO 4401 (size 03) DGM-3-01-1*-R (Metric olt appings) DGM-3-01-1* (UNC olt appings) daptors, Size 05 to 03 For pressures up to 210 bar (3000 psi) Size 3 valves can frequently be used in place of size 5 valves, typically for pilot control functions, or generally where Size 03 Size 05 system flow rate is within that of the size 3 valves. he DGM-3-01 adaptor bolts n to an existing size 05 interface and provides a size 03 mounting face for the smaller valve. 4 holes Ø 7,1 (0.281 dia), counterbored Ø11,1(0.438 dia) 70,00 (2.75) 31,0 (1.22) 14,2 (0.56) 28,4 (1.12) 21,0 (0.83) 5,3 (0.21) 40,5 (1.59) 54,0 (2.12) 90,4 (3.56) Standard port dditional port 18,3 (0.72) 31,75 (1.25) 4 holes tapped: For DGM-3-01-1*-R, M5-6H x 12 (0.47) deep For DGM-3-01-1*, #10-24 UNC-2 x 12,7 (0.5) deep 46,0 (1.81) 0,75 (0.03) 12,0 (0.47) Size 03 Mounting Surface Size 05 Mounting Surface Seals included Supplied complete with bolts for mounting to size 05 interface: M6 bolts with type DGM-3-01-1*-R 1 / 4-20 UNC bolts with type DGM-3-01-1*. EON Industrial Valve Catalog E-VVI-SS001-E October 2016-19

Mounting surfaces to ISO 4401 (size 05) DGMS-3-*E(X)-1*-* Multi-Station Subplates (3-station model illustrated) Valve station 1 Valve stations 2 to 6 1 1 1 1 2 2 2 2 1 1 2 2 hese two ports are: resent in 4-, 5- and 6-station models Optional in 2- and 3-station models, by specifying DGMS-3-2 EX-1*-* or DGMS-3-3 EX-1*-* respectively 2 holes Ø 5,6 (0.22 dia) counterbored to Ø 11,1 (0.438 dia) t each station, 4 holes tapped according to model type (see table): For models with SF ports, M5-6H x 12,0 (0.47) deep. For models with SE ports, #10-24 UNC-2 x 12,7 (0.5) deep. and ports tapped according to model type: For DGMS-3-*E(X)-1*- R: G 1 / 2 ( 1 / 2 SF) For DGMS-3-*E(X)-1*- S: 3 / 4-16 UNF-2 (SE) 68,0 (2.68) 34,0 (1.34) 15,0 (0.6) 38,0 (1.5) 68,0 (2.68) 6,0 (0.24) 15,0 (0.6) 38,0 (1.5) 50,0 (1.97) 50,0 (1.97) 35,0 (1.38) 60,0 (2.36) effective bolt length and ports at each station tapped according to model type: For DGMS-3-*E(X)-1*- R: G 3 / 8 ( 3 / 8 SF) For DGMS-3-*E(X)-1*- S: 3 / 4-16 UNF-2 (SE) Model DGMS-3-2E(X)-1*-* DGMS-3-3E(X)-1*-* DGMS-3-4E-1*-* DGMS-3-5E-1*-* DGMS-3-6E-1*-* 121 (4.8) 171 (6.8) 221 (8.7) 271 (10.7) 321 (12.7) 108 (4.25) 158 (6.22) 208 (8.19) 258 (10.15) 308 (12.12) hrough-connection and ports on types DGMS-3-2EX-1*-* and DGMS-3-3EX-1*-* -20 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Mounting surfaces to ISO 4401 (size 05) Vickers Standard Size 05 Interface his interface conforms to: ISO 4401-05-04-0-94 NSI/93.7M (and NF) size 05 CEO R35H4.2-05 DIN 24340 Form 10 16,7 (0.66) 37,3 (1.47) 27,0 (1.06) 50,8 (2.0) 4 holes, M6-6H x 16 (0.63) min. full thread depth 3,2 (0.12) 6,3 (0.25) 21,4 (0.84) 32,5 (1.28) 46,0 0,1 (1.81 0,004) 69,0 (2.72) min. 5 ports Ø 11,2 (0.44 dia) including optional tank port n 1/4-20 UNC-2 optional. 54,0 0,1 (2.12 0.004) 90,0 (3.54) min. Optional port ( ) Interface with dditional Drain ort he interface conforms to Vickers standard, plus hole ypically used for proportional and other valves requiring an additional drain port, e.g.: KFDG4V-5 KFG4V-5 Interface with dditional ilot orts X and he interface conforms to Vickers standard, plus holes X and ISO 4401-05-05-0-94 ypically used for two-stage directional and proportional control valves requiring additional pilot ports, e.g.: DG5V-5 KDG5V-5 KFDG5V-5 KHDG5V-5 0,5 (0.02) 11,0 (0.433) 8,0 (0.315) 11,0 (0.433) X 62,0 (2.44) Ø 3,0 (0.12 dia) 2 holes Ø 6,3 (0.25 dia) max. EON Industrial Valve Catalog E-VVI-SS001-E October 2016-21

Mounting surfaces to ISO 4401 (size 05) DGM-5--1* lanking late 4 holes Ø 7,14 (0.28 dia) 72,0 (2.84) 70,0 (2.8) 116,0 (4.6) Nameplate 37,0 (1.46) 2,0 (0.08) sealplate DGM-5-C*-1* Crossover late 4 holes Ø 7,14 (0.28 dia) lugs each end, G 1 / 2 ( 1 / 2 SF ) 19,5 (0.77) 72,0 (2.84) 70,0 (2.8) 5,0 (0.2) 116,0 (4.6) Nameplate 5, 0 (0.2) 37, 0 (1.46) 2,0 (0.08) sealplate Model Dimension Dimension DGM-5-C1-1* 25,0 (1.0) 40,0 (1.6) DGM-5-C2-1* 40,0 (1.6) 25,0 (1.0) -22 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Mounting surfaces to ISO 4401 (size 05) DGM-5-1-1*- apping late orts and 4 holes Ø 7,14 (0.28 dia) 18,0 (0.71) 72,0 (2.84) 70,0 (2.8) 31,0 (1.2) 2 ports, G 1 / 2 ( 1 / 2 SF) 116,0 (4.6) Nameplate 37,0 (1.46) 2,0 (0.08) sealplate orts and are tapped M12 x 14 (0.55) deep (e.g. for orifice plugs) on opposite face to sealplate. DGM-5-2-1*- apping late orts and 4 holes Ø 7,14 (0.28 dia) 18, 0 (0.71) 72,0 (2.84) 70,0 (2.8) 45,0 (1.8) 28,0 (1.1) 2 ports, G 1 / 2 ( 1 / 2 SF) 116,0 (4.6) Nameplate 37,0 (1.46) 2,0 (0.08) sealplate orts and are tapped M12 x 14 (0.55) deep (e.g. for orifice plugs) on opposite face to sealplate. EON Industrial Valve Catalog E-VVI-SS001-E October 2016-23

Mounting surfaces to ISO 4401 (size 05) DGM-5-3-1*- apping late orts, and 4 holes Ø 7,14 (0.28 dia) 18,0 (0.71) 72,0 (2.84) 70,0 (2.8) 31,0 (1.2) 3 ports, G 1 / 2 ( 1 / 2 SF ) 116,0 (4.6) orts, and are tapped M12 x 14 (0.55) deep (e.g. for orifice plugs) on opposite face to sealplate. Nameplate 37,0 (1.46) 2,0 (0.08) sealplate DGM-5-1*-*, X and ort daptor lates rovides for external connections to additional pilot ports X and when these ports are not present in subplate/manifold block. ypically used for two-stage directional and proportional valves: DG5V-5 KDG5V-5 KFDG5V-5 KHDG5V-5 X and ports, see table 4 holes Ø 7,14 (0.28 dia) X 44,0 (1.7) X 70,0 (2.8) 72,0 (2.84) Nameplate 32,0 (1.25) 102,0 (4.0) Model DGM-5-1*-R DGM-5-1*-S X and port thread G1 4 (1 4 SF) x 11,0 (0.43) full thread depth 9 16-18 UNF x 12,7 (0.5) full thread depth -24 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Mounting surfaces to ISO 4401 (size 05) Subplate with Side orts,,, Maximum ressure 210 bar (3000 psi) Model type: DGSME-01-2*-8 4 holes Ø 10.8 (0.42 dia) through, softfaced Ø 17,5 (0.66 dia) 18,3 (0.6) 12, 7 (0.5) 101,6 (4.0) 79,4 (3.12) 39,6 (1.6) 4 ports,,, : 3 / 4-16 UNF-2 x 14,3 (0.56) full thread depth 69,0 (2.7) 47,7 (1.9) 47,7 (1.9) 68,3 (2.7) 23,1 (0.9) 91,95 (3.62) 114,3 (4.5) 23,1 (0.9) 38,1 (1.5) 33,0 (1.3) 4 holes tapped 1 / 4-20 UNC-2 x 12,7 (0.5) deep EON Industrial Valve Catalog E-VVI-SS001-E October 2016-25

Mounting surfaces to ISO 4401 (size 05) Subplates with Rear orts,,, Maximum ressure 210 bar (3000 psi) Model types: DGSM-01-2*-8 KDGSM-5-676805-2* (with rear port ) Maximum ressure 280 bar (4000 psi) Model types: EDGSM-01-1*-R EDGSM-01X-1*-R EDGSM-01-1*-R EKDGSM-01-1*-R (with side port ) Rear port, KDGSM-5-676805 only: G 1 / 8 ( 1 / 8 SF) x 12,0 (0.47) full thread depth C 101,6 (4.0) 11,5 (0.45) 4 holes Ø 10,8 (0.42 dia) through, spotfaced Ø 17,5 (0.66 dia) 79,4 (3.12) 12,7 (0.5) 11,2 (0.44) 114,3 (4.5) W K E 68,3 (2.7) 47,5 (1.5) 92,1 (3.62) 69,0 (2.7) 68,3 (2.7) F 11,2 (0.44) 23,1 (0.9) J H N M 5,6 (0.22) 90,4 (3.56) G Side port, EKDGSM-01 only : 9 / 16-18 UNF-2 x 12,7 (0.5) full thread depth 4 holes tapped according to model type: For DGSM-01 and KDGSM-5 models (UNC port threads), 1 / 4-20 UNC-2 x 12,7 (0.5) deep. For EDGSM-01(*) and EKDGSM-01 models (SF port threads), M6-6H x 15,8 (0.62) deep. orts,,, hreads Model 210 bar (3000 psi) DGSM-01-2*-8 KDGSM-5-676805-2* 280 bar (4000 psi) EDGSM-01-1*-R EDGSM-01X-1*-R EDGSM-01-1*-R EKDGSM-01-1*-R ort thread 3 4-16 UNF-2 x 14,0 (0.56) full thread depth G1 4 (1 4 SF) x 12,2 (0.48) full thread depth G3 8 (3 8 SF) x 12,2 (0.48) full thread depth G1 2 (1 2 SF) x 15,0 (0.59) full thread depth Dimensions Model C E F G H J K M N W 210 bar (3000 psi) DGSM-01-2*-8 KDGSM-5-676805-2* 45,2 (1.78) 42,1 (1.66) 19,0 (0.75) 68,3 (2.69) 45,2 (1.78) 23,8 (0.94) 42,1 (1.7) 31,8 (1.25) 23,9 (0.94) 57,1 (2.25) 280 bar (4000 psi) EDGSM-01-1*-R EDGSM-01X-1*-R EDGSM-01-1*-R EKDGSM-01-1*-R 39,7 (1.56) 39,7 (1.56) 39,7 (1.56) 39,7 (1.56) 38,1 (1.5) 40,5 (1.59) 40,5 (1.59) 40,5 (1.59) 13,5 (0.53) 13,5 (0.53) 9,9 (0.39) 9,9 (0.39) 65,5 (2.58) 67,5 (2.66) 70,6 (2.78) 70,6 (2.78) 41,7 (1.64) 39,7 (1.56) 39,7 (1.56) 39,7 (1.56) 10,3 (0.41) 12,7 (0.5) 10,7 (0.42) 10,7 (0.42) 40,9 (1.61) 40,5 (1.59) 40,5 (1.59) 40,5 (1.59) 31,8 (1.25) 31,8 (1.25) 31,8 (1.25) 36,5 (1.44) 23,9 (0.94) 23,9 (0.94) 28,6 (1.13) 28,6 (1.13) 62,7 (2.47) 68,6 (2.7) 72,6 (2.86) 72,6 (2.86) -26 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Mounting surfaces to ISO 4401 (size 05) Subplate with Side orts,,,, Maximum ressure 315 bar (4500 psi) Model type: KDGSM-5-615225-1* KDGSM-5-615226-1* Recommended panel cut-out to clear fittings, Ø 108,0 (4.25 dia) 89,0 (3.5) 75,0 (3.0) ort, G 1 / 4 ( 1 / 4 SF) x 12,0 (0.47), spotfaced to Ø 24,0 (0.94 dia) 42, 0 (1.7) ort, Ø 4,0 (0.16 dia) 80,0 (3.15) 13, 0 (0.51) 4 holes Ø 10,5 (0.41 dia) 46,0 (1.81) 47,5 (1.9) 77,5 (3.1) Z 1,0 (0.04) 23, 0 (0.9) 67,0 (2.6) 115,0 (4.6) 92,0 (3.62) 5,0 (0.2) 40,0 (1.6 ) 12,5 (0.5) 17,0 (0.7) orts,,,, Ø10,5 (0.41 dia) 88,0 (3.5) 120,0 (4.8) 4 holes M6 x 14,0 (0.55) full thread depth art Section - orts,,, Model thread Z diameter KDGSM-5-615225-1* KDGSM-5-615226-1* G1 2 (1 2 SF) x 14,0 (0.55) full thread depth G3 4 (3 4 SF) x 16,0 (0.63) full thread depth 30,0 (1.18) 33,0 (1.3) EON Industrial Valve Catalog E-VVI-SS001-E October 2016-27

Mounting surfaces to ISO 4401 (Sizes 07 and 08) Vickers Standard Size 07 Interface his interface conforms to: ISO 4401-07-06-0-94 NSI/93.7M (and NF) size 07 CEO R35H4.3-07 DIN 24340 Form 16 1,6 0,1 (0.063 0.004) 15,9 (0.63) 18,3 (0.72) 101,6 0,1 (4.0 0.004) 88,1 (3.47) 76,6 (3.016) 65,9 (2.59) 50,0 (1.97) 34,1 (1.34) 2 holes Ø4,0 (0.157 dia) x 8,0 (0.31) min. dept h 4 holes M10 x 17,0 (0.67) min. full thread depth 71,5 0,1 (2.815 0.004) 69,8 0,1 (2.75 0.004) 57,2 (2.25) 55,6 (2.19) 34,9 (1.38) 14,3 (0.56) X 95,0 (3.74) min. 11,0 (0.43) 130,0 (5.12) min. n 3 / 8-16 UNC optional. 1 / 4-20 UNC optional. 3 holes (ports, X, ) Ø 6,3 (0.25 dia) max. 4 holes (ports,,, ) Ø 17,5 (0.69 dia) max. 2 holes M6-6H x 17,0 (0.67) min. full thread depth Vickers Standard Size 08 Interface his interface conforms to: ISO 4401-07-06-0-94 NSI/93.7M (and NF) size 07 CEO R35H4.3-07 DIN 24340 Form 16 94,5 0,1 (3.720 0.004) 77,0 (3.03) 53,2 0,1 (2.094 0.004) 29,4 0,1 (1.157 0.004) 130,2 0,1 (5.126 0.004) 112,7 (4.437) 100,8 (3.968) 2 holes Ø 7,5 (0.295 dia) x 8,0 (0.31) min. depth orts X,: Ø 11,2 (0.44 dia) max. 17,4 (0.685) 19,0 (0.748) 17,5 (0.689) 5,6 (0.22) 4,8 0,1 (0.189 0.004) 92,1 0,1 (3.626 0.004) 74,6 (2.937) 73,0 (2.874) 46,0 (1.181) X 118,0 (4.65) min. 1 / 2-13 UNC optional. Vickers uses port for pressure-centered and other options not in high demand. ort : Ø 11,2 (0.44 dia) max. 153,0 (6.02) min. 6 holes, M12-6H x 20,0 (0.78) min. full thread depth orts,,, : Ø 23,4 (0.92 dia) max. -28 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Mounting surfaces to ISO 4401 (sizes 07 and 08) For up to 350 bar (5000 psi) Maximum ressure orts,,,, X, DGSM-8-1*-** (UNF/SE ports; UNC mounting bolts) X 120,0 (4.73) 60,0 (2.36) 75,0 (2.95) 96,0 (3.78) 35,0 (1.38) 60,0 (2.36) 13,0 (0.51) 21,5 (0.85) 9,0 (0.35) 160,0 (6.3) 184,0 (7.25) 30,0 (1.18) X 150,0 (5.9) 140,0 (5.51) X 36,5 (1.44) 52,5 (2.07) 91,5 (3.6) 107,5 (4.23) 4 holes Ø 9,0 (0.35 dia) through, spotfaced Ø 14,5 (0.57 dia) 6 tapped holes for valve mounting, see table 29,0 (1.14) 61,0 (2.4) For port tappings according to model code, see table ort and olt hreads Model orts,,, orts, X, Mounting bolt tapping EDGVM-7-D-1*-R G1 (1 SF) x 19,0 (0.75) full thread depth G1 4 (1 4 SF) x 12,0 (0.47) full thread depth 4 x M10 2 x M6 EDGVM-7Z-D-1*-S 115 16-12 UN-2 x 19,0 (0.75) full thread depth 9 16-18 UNF-2 x 12,7 (0.5) full thread depth 4 x 3 8-16 UNC 2 x 1 4-20 UNC 33 EON Industrial Valve Catalog, Section September 2012 EON Industrial Valve Catalog E-VVI-SS001-E October 2016-29

Mounting surfaces to ISO 4401 (sizes 07 and 08) For up to 210 bar (3000 psi) Maximum ressure DGSM-04-12S-2* (UNF/SE port threads; UNC mounting bolts) For up to 350 bar (3000 psi) Maximum ressure EDGVM-7X-D-1*-R (SF port threads; metric mounting bolts) X 140,0 (5.51) C D Ø 8,73 (0.344 dia) 25,0 (1.0) Ø 14,5 (0.57 dia) Ø 9,9 (0.389 dia) 12,6 (0.5) E 89,0 (3.5) 92,0 (3.62) 42,5 (1.67) X H G F 69,9 (2.75) 38,1 (1.5) 35,0 (1.38) 14,3 (0.65) M K DGSM-04 Only EDGVM-7X Only J 160,0 (6.3) For port tappings according to model code, see table ort and olt hreads Model orts,,, orts, X, Mounting bolt tapping DGSM-04-12S-2* 1-12 UNF-2 x 19,1 (0.75) full thread depth 9 16-18 UNF-2 x 12,7 (0.5) full thread depth 4 x 3 8-16 UNC 2 x 1 4-20 UNC EDGVM-7X-D-1*-R G3 4 (3 4 SF) x 16,0 (0.63) full thread depth G1 4 (1 4 SF) x 12,0 (0.47) full thread depth 4 x M10 2 x M6 Dimensions Model C D E F G H J K M DGSM-04-12S-2* EDGVM-7X-D-1*-R 121,4 (4.78) 128,6 (5.06) 88,4 (3.48) 93,6 (3.68) 44,2 (1.74) 50,6 (1.99) 56,6 (2.23) 55,6 (2.19) 54,9 (2.16) 52,0 (2.05) 18,3 (0.72) 15,9 (0.63) 121,4 (4.78) 113,6 (4.47) 76,7 (3.02) 79,6 (3.13) 32,3 (1.27) 36,6 (1.44) -30 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Installation dimensions in mm (inches) (sizes 07 and 08) For up to 350 bar (5000 psi) Maximum ressure orts,,,, X, EDGVM-8(*)-1*-R (SF port threads; metric mounting bolts) EDGVM-8-1*-S (UNF/SE port threads; UNC mounting bolts) orts,,,, X, and X EDGVM-8(*)-1*-R (SF port threads; metric mounting bolts) EDGVM-8-1*-S (UNF/SE port threads; UNC mounting bolts) his profile on model types EDGVM-8 and -8Z only ort, see table M orts,,,, see table F N G S X E D C X H R 4 holes Ø ( dia), see table ort X, see table K J 6 tapped holes for valve mounting, see table EDGVM-8(*)-D -1*-* models only ort, see table ort hreads, olt appings and Dimensions Mounting bolt orts,,, orts, X, Model tappings EDGVM-8(-D)-1*-R G3 4 x 16 (0.63) G1 4 x 12,2 (0.48) M12 x 25 deep (SF) deep (SF) (1.0) deep EDGVM-8X(-D)-1*-R G1 x 19 (0.74) G1 4 x12,2 (0.48) M12 x 25 deep (SF) deep (SF) (1.0) deep EDGVM-8(-D)-1*-R G11 4 x 21 (0.82) G1 4 x12,2 (0.48) M12 x 25 deep (SF) deep (SF) (1.0) deep EDGVM-8(-D)-1*-S 15 8-12 UN x 9 16-18 UNF x 1 2-13 19,1 (0.75) deep 12,7 (0.5) deep UNC-2 EDGVM-8Z(-D)-1*-R G11 2 x 22 (0.86) G1 4 x12,2 (0.48) M12 x 25 deep (SF) deep (SF) (1.0) deep C D E F 54,8 (2.16) 49,6 (1.95) 50,5 (1.99) 50,5 (1.99) 50,5 (1.99) 78,6 (3.09) 73,4 (2.89) 74,2 (2.92) 74,2 (2.92) 74,2 (2.92) 102,4 (4.03) 107,5 (4.23) 128,0 (5.04) 128,0 (5.04) 128,0 (5.04) 126,2 (4.97) 131,4 (5.17) 151,8 (5.98) 151,8 (5.98) 151,8 (5.98) 160 (6.30) 160 (6.30) 185 (7.28) 185 (7.28) 185 (7.28) 74,6 (2.94) 74,6 (2.94) 103 (4.06) 103 4.06) 103 4.06) Dimensions Model G H J K M N R S Ø EDGVM-8(-D)-1*-R EDGVM-8X(-D)-1*-R EDGVM-8(-D)-1*-R EDGVM-8(-D)-1*-S EDGVM-8Z(-D)-1*-R 19 (0.75) 33 (1.30) 21 (0.83) 17,5 (0.69) 31 (1.22) 5,6 (0.22) 17,4 (0.685) 27 (1.06) 73 (2.87) 97 (3.82) - - 72 (2.84) 35 (1.38) 45 (1.77) 119 (4.69) 160 (6.30) 181 (7.13) 202 (7.95) 92,1 (3.63) 130 (5.12) 204 (8.03) 232 (9.13) 10,8 (0.425) 13,5 (0.53) EON Industrial Valve Catalog E-VVI-SS001-E October 2016-31

Mounting surfaces to ISO 4401 (sizes 07 and 08) For up to 210 bar (3000 psi) Maximum ressure orts,,,, X, DGSM-8-1*-** (UNF/SE ports; UNC mounting bolts) X 4 holesø 10,8 (0.42 dia), spotfaced Ø17,5 (0.68 dia) 134,9 (5.3) 1,5 (0.05) 40,0 (1.6) 41,3 (1.62) 168,0 (6.6) 67,5 (2.65) X 34,8 (1.4) 92,1 (3.62) 26,2 (1.03) X 79,2 (3.12) 124,0 (4.9) 68,3 (2.7) 111,1 (4.4) 10,6 (0.4) 25,4 (1.0) 32,0 (1.26) 111,1 (4.4) 136,6 (5.38) 4 holes tapped according to model type: For EDGSM-03(X)-1*-R models (SF ports): M6-6H x 16,0 (0.63) full thread depth For EDGSM-03X-1*-S models (UNC ports): ¼ -20 UNC-2 x 16,0 (0.63) full thread depth ort hreads Model orts,,, orts X, DGSM-8-1*-12 11/16-12 UN x 19,1 (0.75) deep 9/16-18 UNF x 12,7 (0.5) deep DGSM-8-1*-16 15/16-12 UN x 19,1 (0.75) deep 9/16-18 UNF x 12,7 (0.5) deep -32 EON Industrial Valve Catalog E-VVI-SS001-E October 2016

Mounting surfaces to ISO 4401 (size 10) Millimeters (Inches ) machined pad must be provided for mounting. ad must be flat within 0,127 mm (.0005 inch) and smooth within 1,6 μm (63 microinch). Mounting bolts, when provided by customer, should be SE grade 7 or better. 44,4 (1.75) - ank connection 41,3 (1.62) 34,9 (1.38) 230,1 (9.06) 168,3 (6.62) 147,6 (5.81) 138,6 (5.46) 114,3 (4.50) 82,6 (3.25) 76,2 (3.00) 190,5 (7.50) - ressure connection 7,1 DI (.28 DI) ocation per ISO-4401-10-08-0-94 7,1 DI (.28 DI) ocation per NSI 93.7M-1986 M20 hread (.7500-10 UNC hread - ilot valve drain connection 198,9 (7.83) 158,8 (6.25) 130,2 (5.12) 123,8 (4.88) 79,4 (3.12) W - External drain 11,2 DI (.44 DI) 2 places 31,8 DI (1.25 DI) 4-laces X - External pilot pressure connection 7,1 DI (.28 DI) ort connection ort connection Required for D pressure centered models only Subplates Subplates must be ordered separately. For 210 bar (3000 psi) applications, order Subplate DGSM-10-24S-11. Subplate not available for 350 bar (5000 psi) applications. Mounting olts olt kits must be ordered separately. Use olt Kit KDG10-636-255636. Maximum recommended bolt torque is 210 lb. ft. (286 N.m). ort connection "X" - External pilotpressure connection.8750-14 UNF-2 HD.From rear (2 holes) n16.7 [.657](4 holes for mounting) 35.1 [1.38] 158.8 [6.25] 123.7 [4.87] 122.2 [4.81] 36.6 [1.44] 28.5 [1.12] 304.8 [12.0] 150.9 [5.94] 30.7 [1.21] 147.6 [5.81] 266.7 [10.5] 38.1 [1.5].750-10 UNC-2 HD (6 HOES) ort connection ""-ressure connection 9.5(.375) Drill 26.2(1.03) Deep ""-ilot valve drain Connection (not required for Internally drained models) 44.5 [1.75] 22.9 [.90] 196.9 [7.75] 28.6(1.125) Drill 22.4(.88) Deep (4 Holes) "" ank connection n28.6(1.125)(4 holes) System ports 1.875-12 UN-2 HD. (From rear)(4 holes)-system connections 41.1 [1.62] 75.2 [2.96] 114.3 [4.5] 168.1 [6.62] 190.5 [7.5] n7.1(.281)-7.9(.31) Deep (2 Holes for rest pins) 25.4 [1.00] EON Industrial Valve Catalog E-VVI-SS001-E October 2016-33

Eaton Hydraulics usiness US 14615 one Oak Road Eden rairie, MN 55344 US el: 952-937-9800 Fax: 952-294-7722 www.eaton.com/hydraulics Eaton Hydraulics usiness Europe Route de la ongeraie 7 1110 Morges Switzerland el: +41 (0) 21 811 4600 Fax: +41 (0) 21 811 4601 Eaton Hydraulics Group sia acific Eaton uilding 4 th Floor, No. 3 ane 280 inhong Rd. Changning District Shanghai 200335 China el: (+86 21) 5200 0099 Fax: (+86 21) 5200 0400 2016 Eaton ll Rights Reserved rinted in US Document No. E-VVI-SS001-E October 2016