Electronic Water Meters

Similar documents
Electronic Water Meters

Electronic Water Meters in measuring cell design

Electronic Heat Meters

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

Measuring capsule heat meter G54 / G55

Heating Cost Allocation Valve with local acquisition of the flow temperature

EW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS

Supercal 539. Compact thermal energy meter

HYDRUS ULTRASONIC METER

CORONA ER ELECTRONIC METER MULTI-JET

HYDRUS ULTRASONIC METER

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Fluidic Oscillation Compact Heat Meter

SonoMeter 30 Energy Meters

TOPAS PMW-basic. Customer benefits. Product features

Residential Water Meters

SonoMeter 30 Energy Meters

M-bus impeller type heat and heat/refrigeration meters

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Superstatic 749. Fluidic Oscillation Compact Heat Meter

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

RAY COMPACT ENERGY METER MECHANICAL

CORONA E ELECTRONIC METER MULTI-JET

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

WESAN WPV E ELECTRONIC METER WOLTMAN

aquaconcept Product features Customer benefits

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

3-Port Seat Valves with Male Thread, PN 16

Paddle-wheel flow controller with optical principle for On/Off control

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.

F 90 Heat Meter Warmly recommended to cool-headed economisers

MULTI-JET WATER METERS

zelsius Installation and operating manual All that counts. EnergyMetering

zelsius Installation and operating manual All that counts EnergyMetering

Pressure Sensors. for liquid and gaseous media

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

ELSTER KENT Non-Metalic Products. Meters, Meterboxes & Accessories made from Engineering Plastics

WZMC-402 Ultrasonic Apartment Energy Meters

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

Domestic water meters

Compact Static Heat Meter of High-Tech Composite

AVL PLU 131U FLOW METER

3-port seat valves, external thread, PN16

Domestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features

Type Electronic Limit Switch

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Paddle-wheel flow controller for On/Off control

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Differential Pressure Sensors

3-Port Seat Valves with Male Thread, PN 16

TOPAS PMW-basic Hot water meter

Electronic Limit Switch Type

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

VPI45..Q with pressure test points. Combi valves, PN 25

INSERTION flow sensor for continuous flow measurement

Superstatic 440. Static Heat- and Cooling Meter. Application

COMPONENTS FOR SOLAR THERMAL SYSTEMS

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

2-port and 3-port valves with T-bypass PN 16

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Compressed Air-Supply Meter

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

VPI45..Q with pressure test points. Combi valves, PN 25

Combi valves PN 16 with flanged connections

Horizontal Distribution Units - HDU Multi-port

Pressure sensor for liquid and gaseous media QBE620-P...

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Mounting and Operating Instructions EB 5868/5869 EN

Terminator PICV. Technical Manual

SonoSelect and SonoSafe energy meters

Directional spool valves type SWPN

Series 7000 Torque Sensor for PTO-shafts

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

Two-port seat valves with male thread, PN16

A1 Commercial Grade Meters

Series 7000 Torque Sensor for PTO-shafts

testo 338 Portable Soot and Particulate Meter Versatile, digital display of particulates

Differential Pressure Sensors

Magnetic-Inductive Flow Meter FMI

Heat Meter Integrator

Operating Instructions

MODEL 200 MULTI-JET FLOW METER

S 100 Single-jet Water Meter Unobtrusively upmarket just what it should be

2-port and 3-port terminal unit valves PN16

Supercal 539 Universal compact heat meter

FTB 372 Series Axial Turbine Flow Meter

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

AVL Particle Measurement System Aviation

Modulating control valves with magnetic actuators, PN 16

RVD G2383en. Installation. - Compact station - Control cabinet (in the front, on the inner wall or on a

Magnetic-Inductive flow Meter fmi

2-Port and 3-Port Zone Valves PN 16

a q u a c o n c e p t Applications Features Benefits

tprime TM Series 280T

WESAN WP WOLTMAN METER

Transcription:

5 328 SIEMECA Electronic Water Meters WFC WFH Electronic, mains-independent meters to acquire water consumption in autonomous domestic water plants. Storage and display of the cumulated consumption values on a selectable set day. Available as single-jet meters with flow rates of 1.5 m 3 /h or 2.5 m 3 /h. The electronic Siemeca water meter is a component of the Siemeca AMR system and can be read out or programmed via an IrDA interface. Use The electronic Siemeca water meters are used for measuring water consumption. Their major field of use are central domestic water plants, where water is delivered to several individual consumers. Plants of this type are used in buildings such as multifamily houses office and administrative buildings Typical users are: Private building owners Property associations Building maintenance companies Housing estate agents CE1N5328en 18.04.2004 Siemens Building Technologies HVAC Products

Functions Acquisition of water consumption Cumulation of the consumption values Storage of the cumulated consumption values on the set day Display of the consumption values Display of key operational data Self-supervision, with fault indication Wireless data transmission Leakage detection Optional programming and reading via an optical interface (IrDA-compatible) with a handheld terminal Type summary List of electronic single-jet cold water meters (max. water temperature 30 C) Siemeca AMR 1.5 m 3 /h 80 G 3 / 4 Radio 868 MHz WFC36.D080 1.5 m 3 /h 110 G 3 / 4 Radio 868 MHz WFC36.D110 2.5 m 3 /h 130 G1 Radio 868 MHz WFC36.E130 List of electronic single-jet hot water meters (max. water temperature 90 C) Siemeca AMR 1.5 m 3 /h 80 G 3 / 4 Radio 868 MHz WFH36.D080 1.5 m 3 /h 110 G 3 / 4 Radio 868 MHz WFH36.D110 2.5 m 3 /h 130 G1 Radio 868 MHz WFH36.E130 List of electronic single-jet cold water meters (max. water temperature 30 C) 1.5 m 3 /h 80 G 3 / 4 IrDA WFC37.D080 1.5 m 3 /h 110 G 3 / 4 IrDA WFC37.D110 2.5 m 3 /h 130 G1 IrDA WFC37.E130 List of electronic single-jet hot water meters (max. water temperature 90 C) 1.5 m 3 /h 80 G 3 / 4 IrDA WFH37.D080 1.5 m 3 /h 110 G 3 / 4 IrDA WFH37.D110 2.5 m 3 /h 130 G1 IrDA WFH37.E130 2/6

List of accessories Accessory Description, scope of delivery Type reference Spacer For mounting length 80 mm (¾" male) WFZ.R80 Spacer For mounting length 110 mm (¾" male)) WFZ.R110 Spacer For mounting length 130 mm (1" male) WFZ.R130 Threaded joints ½ external thread, ¾ union nut WFZ.R2 Threaded joints ¾ external thread, 1 union nut WFZ.R2-1 Readout software Parameterization and diagnoses tool Readout software with PC module for administration and data storage and PDA module for readout Parameterization and diagnoses tool with PDA ACS200 ACT200 Programming stick Tool for starting radio installation telegrams WFZ.PS PDA Handheld computer WHZ3.PDA Ordering Technical design When ordering, please give type reference according to Type summary. The electronic Siemeca water meter comes standard with an IrDA interface. If a set day other than December 31 is required, the desired month is to be added to the type reference when ordering (normally, the last day of the month is the set day). Ordering example for a water meter, 110 mm mounting length, set day April 30: WFC36.D110, set day: April Measuring principle Storage of consumption values Display The meter operates based on the single-jet measuring principle where the water jet hits the impeller tangentially. The impeller's speed is sensed magnetically with a GMR sensor. The water consumption values are continuously cumulated. At 23.59 hours of the next set day, the actual meter reading will be stored. The set day is factory-set, the standard setting being December 31 (also refer to Ordering ). At the time the annual consumption values are stored, the meter calculates a verification code. Tenants who make their own reading need to give this code to the billing center, along with the set day reading. This enables the billing center to verify the reading. The water meter has a rolling display which shows the following values and variables: Cumulated water consumption since the meter was first installed Segment test With the Siemeca parameterization tools, the following displays can be switched step by step: Cumulated water consumption since the last set day Set day Verification code Actual flow rate Indication of faults (also refer to section below) The units displayed are m 3 and m 3 /h. Standard display is the cumulated water consumption. Fault status signals The meter monitors itself and can display faults that it has detected. In case of a leak in the piping system, the flow direction arrow on the meter s display will start flashing after 60 minutes 3/6

Mechanical design The water meter is comprised of flow measuring section and electronic unit. The flow measuring section is mounted in the piping with the help of fittings. It is made of brass and contains the measuring chamber with the single-jet impeller. The inlet has a strainer to retain larger dirt particles. The meter is supplied as a compact all-in-one unit. Electronic display unit The electronic display unit houses the electronics and the 8-digit LCD. Operating voltage of DC 3 V is supplied by a lithium battery. Underneath the display, there is the IrDA interface for automatic meter readout. The electronic display unit on the flow measuring section can be swiveled through 360. Sizing p 1,0 Q p 1,5 m 3 /h Q p 2,5 m 3 /h 0,5 0,4 0,3 0,2 0,1 0,05 0,04 0,03 0,02 0,01 0,2 0,3 0,4 0,5 0,6 1,0 1,2 1,5 2 2,5 3 4 5 6 Q 5333D01 Pressure drop characteristic p Pressure drop in bar Q Flow rate in m 3 /h Mounting notes The local regulations for the use of water meters (mounting, sealing, operation, etc.) must be complied with To facilitate readout and service work, the meter should be easily accessible A settling path is required just upstream of the meter: 150 mm with the mounting lengths of 80 mm and 110 mm 200 mm with the mounting length of 130 mm If the meter is only used after commissioning, it is possible to fit the spacer first Prior to mounting the meter, the piping must be thoroughly flushed; for this purpose, the spacer is required When mounting the meter, the direction of flow (indicated by an arrow on the body) must be observed The display unit should be located such that it is easy to read After mounting, the required test pressure must be applied to the plant The display unit and the fittings must be sealed to ensure protection against tampering. If required, the M-bus service interface must also be sealed Operating notes For recalibration, the local regulations must be observed For sending out the installation telegrams, the relevant Siemeca parameterization tools are required 4/6

Technical data Measurement accuracy class (DIN ISO 4064/1) Horizontally Vertically Unit m 3 Flow rates Min. flow rate Q min H / V Lower limit of flow rate Q t Nominal flow rate Q nenn Max. flow rate Q max Starting flow, horizontal Max. perm. operating pressure Range of use of flow measuring section 1 90 C Behavior in the event of excessive flow Flow rate = 2 q max Flow rate > 2 q max Perm. ambient temperature Transport und storage Operation B B 1.5 m 3 /h 2.5 m 3 /h 30 l/h 50 l/h 120 l/h 200 l/h 1,500 l/h 2,500 l/h 3,000 l/h 5,000 l/h 3 l/h 5 l/h 10 bar linear constant 5 55 C max. 55 C Degree of protection IP 64 Battery life 12 years + 6 months (storage) Connections and weight Pipe connection (inlet and outlet) Mounting length Weight 1.5 m 3 /h 1.5 m 3 /h 2.5 m 3 /h ¾ ¾ 1 80 mm 110 mm 130 mm 0.55 kg 0.6 kg 0.7 kg Dimensions 5/6

Dimensions in mm This Data Sheet only contains general descriptions and technical features which, in the case of specific applications, may not necessarily apply, or which may change due to further development of the product. Technical details and features are binding only if explicitly agreed upon at the time of contract closure. 6/6 2004 Siemens Building Technologies AG Subject to alterations