Mounting and Operating Instructions EB 5868/5869 EN
|
|
- Claud Pearson
- 6 years ago
- Views:
Transcription
1 Electric Control Valves Types 3213/5857, 3213/5824, Types 3214/5824, 3214/3374, 3214/3274 with safety function: Types 3213/5825, 3214/5825, 3214/3374, 3214/3274 Pneumatic Control Valves Types 3213/2780-1, , 3214/ Type 3213/5857 Electric Control Valve Type Electric Control Valve Type 3213/ Pneumatic Control Valve version for steam Type 3214/3274 Electric Control Valve Mounting and Operating Instructions EB 5868/5869 EN Edition April 2006
2 Contents Contents 1 Design and principle of operation Versions Technical data Installation Mounting position Strainer Additional installation instructions Attaching the actuator to the valve Type 5857 Actuator Type 5824/5825 Actuators Type 3274 and Actuators Type /-21 Actuators Type /-2 Actuators Electrical connections Type 5857 Electric Actuator Type 5824/5825, Type 3374 Electric Actuators Type 3274 Actuator Pneumatic connection of Type /-2 Actuators Operation Manual override Type 5857 Actuator Type 5824/5825 Actuators Type 3374 Actuator Type 3274 Actuator Version with mechanical override Version with electric override Disconnect terminal Maintenance Dimensions in mm and weights Typetest Electric actuators with safety function in conjunction with valves are typetested according to DIN by the German technical inspectorate TÜV. Register number available on request. 2 EB 5868/5869 EN
3 General safety instructions General safety instructions The control valves may only be mounted, started up or serviced by fully trained and qualified personnel, observing the accepted industry codes and practices. Make sure employees or third persons are not exposed to any danger. All safety instructions and warnings in these mounting and operating instructions, particularly those concerning assembly, start-up and maintenance, must be observed. The control valves fulfill the requirements of the European Pressure Equipment Directive 97/23/EC. Valves with a CE marking have a declaration of conformity which includes information about the applied conformity assessment procedure. The declaration is available on request. For appropriate operation, make sure that the control valve is only used in applications where the operating pressure and temperature do not exceed the operating values which are based on the valve sizing data submitted in the order. The manufacturer does not assume any responsibility for damage caused by external forces or any other external influence! Any hazards which could be caused in the control valve by the process medium, the operating pressure, the signal pressure or by moving parts are to be prevented by means of the appropriate measures. Proper shipping and appropriate storage of the control valve are assumed. Caution! For installation and maintenance, make sure the relevant section of the pipeline is depressurized and, depending on the process medium, drained as well. If necessary, allow the control valve to cool down or warm up to reach ambient temperature prior to starting any work on the valve. The electric actuators have been designed for use in electrical power installations. For wiring and maintenance, you are required to observe the relevant safety regulations. Only use power interruption devices which are protected against unintentional reconnection of the power supply. Take special care when making adjustments on live parts. Do not remove any covers! EB 5868/5869 EN 3
4 Design and principle of operation 1 Design and principle of operation The control valves consist of a Type 3213 or Type 3214 Globe Valve (balanced) and either an electric or pneumatic actuator. Valves in DN 15 to 50 sizes have a force-locking connection and valves in DN 65 to 250 sizes have a form-fit connection. The process medium flows through the valve in the direction indicated by the arrow. The position of the valve plug determines the flow rate over the cross-sectional area released between the plug (3) and valve seat (2). The plug is moved by a change in the control signal acting on the actuator. In balanced valves, the upstream pressure is transferred through the hole in the plug stem (6) to the outside of the bellows and the downstream pressure to the inside of the bellows. The forces acting on the valve plug are thus eliminated and the valve is fully balanced. Control valves with safety function (Type 5825, Type , Type Actuators) are equipped with a spring-return mechanism. On interruption of the safety interlock circuit or when the power fails, the control valve closes. For the pneumatic control valves, the fail-safe action of the Type and Pneumatic Actuator is determined by the actuator springs in either the top or bottom diaphragm chamber to either close the valve (actuator stem extends) or open the valve (actuator stem retracts) when the signal pressure fails. The Type Actuator allows integral positioner attachment. 1 Valve body 2 Seat 3 Plug 4 Bellows housing 4.1 Balancing bellows 5 Connecting or insulating section 6 Plug stem 6.1 Spring 8 Actuator 8.1 Coupling nut 8.2 Actuator stem 8.3 Torque switch 8.4 Handwheel (Types 5857, 5824) 8.5 Actuating shaft 9 Travel indicator scale 10 Stem connector Fig. 1 Functional diagram of Type 3213/ Pneumatic Control Valve 4 EB 5868/5869 EN
5 Design and principle of operation Type 5857 Actuator Type /-21 Actuator Type 3274 Actuator Type Actuator Type 5824 Actuator Type 3214/ Type 3214/ Type 3213/5824 Type 3214/3274 Type 3214/ Fig. 2 Functional diagrams of Types 3213/5857, 3213/5824, 3214/3374, 3214/3274 Electric Control Valves EB 5868/5869 EN 5
6 Design and principle of operation 1.1 Versions Type 3213 Globe Valve with unbalanced plug PN DN EB* Electric control valves Type 3213/ to to 25 Type 3213/ to 50 with safety function (typetested) Type 3213/5825 Pneumatic control valves Type 3213/ Type 3213/ to to to to to to * Refer to the mounting and operating instructions (EB) for more details on the actuators. Type 3214 Globe Valve with pressure-balanced plug PN DN EB* Electric control valves Type 3214/ to Type 3214/ to to Type 3214/ to with safety function (typetested) Type 3214/ to Type 3214/ to to Type 3214/ to Pneumatic control valves Type 3214/ to to * Refer to the mounting and operating instructions (EB) for more details on the actuators. 1.2 Technical data Pressure-temperature diagram All permissible pressures and differential pressures specified in the tables are restricted by this diagram and the nominal pressure rating. 6 EB 5868/5869 EN
7 Design and principle of operation 1a. Type 3213 Globe Valve Nominal size DN Nominal pressure PN 25 PN 16 Permissible temperature (upright) C Version for steam C 200 On request Rated travel mm 6 12 Rangeability 50 : 1 Leakage class < 0.05 % of K VS coefficient Materials Nominal pressure PN 16 PN 25 Valve body EN-JL1040 (GG-25) EN-JS1049 (GGG-40.3) Seat Plug with metal sealing Brass with EPDM soft sealing or FPM (FKM) seal Special version K VS = 0.1 to 2.5: with metal sealing Plug stem Spring Guided nipple Brass with EPDM seal or FPM (FKM) seal Insulating section Nominal size and K VS coefficients Nominal size DN Rated travel mm K VS coefficient Max. differential pressure in bar Type 5824/Type Type Special version K VS coefficient Max. differential pressure in bar Type 5824/Type Type EB 5868/5869 EN 7
8 Design and principle of operation 1b. Type 3214 Globe Valve Nominal size DN Nominal pressure PN 16 to 40 Perm. temperature (upright) C 150 1) ) Rated travel mm Rangeability 50 : 1 40 : 1 30 : 1 Leakage class 1) Version with insulating section: 220 C 2) Special version with metal-seated plug: 220 C < 0.05 % of K VS coefficient Materials Nominal pressure PN 16 PN 25 PN 40 Valve body EN-JL1040 1) EN-JS1049 or Seat and plug DN 15 to 100 CrNi steel Special version with EPDM soft sealing DN 125 to 250 CrNiMo steel with EPDM soft sealing Special version with metal sealing Plug stem Bellows housing Balancing bellows Guided nipple DN 15 to 50 Brass with EPDM seal or FPM (FKM) seal Packing DN 65 to 250 V-ring packing PTFE with carbon Insulating section with EPDM seal or FPM (FKM) seal 1) Special version EN-JS1049 or Nominal sizes and K VS coefficients Nominal size DN Rated travel mm K VS coefficient With flow divider Max. differential pressure bar ) 16 1) ) 10 2) 10 2) 1) With Type 3374 Actuator: Δp = 20 bar 2) Special version needed with Type 3274 Actuator 8 EB 5868/5869 EN
9 Design and principle of operation 2. Electric actuators Actuators mounted on Type 3213/3214 Globe Valves Type 3213 Type 3214 Nominal size DN 15 to to to to to to 250 Type ) 5857 without safety function Rated travel mm Transit time for rated travel s ) ) Nominal thrust kn Power consumption VA Max. 18 Approx. 90 Manual override Handwheel Hex wrench Electric Mech. Type with safety function Rated travel mm Transit time f. rated travel s ) ) ) 120 3) Transit time upon failure s ) 43 3) Fail-safe action Stem extends Stem retracts Nominal thrust kn Power consumption VA Max. 18 Approx. 90 Power supply Voltage V 230/ / 24 4) / 24 4) /24 4) 230/110/24 Frequency Hz ) ) ) 50/60 Perm. ambient temperature 0 to 50 C 5 to 60 C 10 to 60 C Degree of protection IP 42 IP 54 (installed upright, acc. to DIN IEC 529) IP 54/IP 65 with cable gland Additional electrical equipment Limit switches Potentiometer Electric positioner 5) ) Other actuators available on request 4) Other frequencies and voltages on request 2) Actuator with faster motor 5) Available on request 3) Shorter transit times available on request IP 65 EB 5868/5869 EN 9
10 Design and principle of operation 3. Pneumatic actuators Type Actuators mounted on Type 3213/3214 Globe Valves Type 3213 Type 3214 Nominal size DN 15 to to 100 Diaphragm area cm Maximum supply pressure bar 4 4 Fail-safe action Reversible by changing the location of the springs Bench range bar 0.4 to to 2 1) Required supply pressure bar Permissible temperature C 10 to 80 (special version: 35 to 120) Number of actuator springs 3 6 (3 for DN 15 to 25) Loading pressure connection ISO 288/1, G 1 8; 1 8 NPT 1) With Type 3214, DN 65 to 100: 2.1 to 3.3 bar for fail-safe action with stem extends 0.4 to 1.4 bar for stem retracts Materials Type /-2 Actuator housing Aluminum GD-AlSi12 1) Diaphragm NBR Springs Spring wire C 1) External bolts Bushing Chromated steel CW617N (CuZn40Pb) 1) Without paint or surface treatment 10 EB 5868/5869 EN
11 Installation 2 Installation 2.1 Mounting position The mounting position of the control valves is upright in the pipeline. However, other mounting positions may be possible on request. Choose the place of installation that allows you to freely access the control valve even after the entire plant has been completed. Install a strainer upstream of the control valve to prevent any sealing parts, weld spatter or other foreign matter carried along by the process medium from impairing the proper functioning of the valve, in particular, the tight shut-off. Note! The valve body must be installed free of stress and with the least amount of vibrations possible. If necessary, support the piping near the connections. Flush the pipeline thoroughly before installation. 2.2 Strainer Install the strainer with the filter element facing downwards upstream of the valve inlet. Install the strainer with the flow direction as indicated by the arrow on the body. Choose the place of installation to allow enough space to remove the filter. 2.3 Additional installation instructions We recommend to install a hand-operated shut-off valve both upstream of the strainer and downstream of the control valve to be able to shut down the plant for cleaning and maintenance, and when the plant is not used for longer periods of time. 3 Attaching the actuator to the valve If the actuator has not already been mounted on the valve by the manufacturer or the original actuator is to be replaced with another actuator, remove the transportation protection and proceed as follows. 3.1 Type 5857 Actuator 1. Turn the handwheel (see section 6) counterclockwise disconnected from the power supply to retract the actuator stem as far as it will go. 2. Place the actuator on the connection piece and secure with the coupling nut (tightening torque: 20 Nm). 3.2 Type 5824/5825 Actuators Type Turn the handwheel (see section 6) counterclockwise to retract the actuator stem as far as it will go. EB 5868/5869 EN 11
12 Attaching the actuator to the valve 2. Place the actuator on the connection piece and secure with the coupling nut (tightening torque: 20 Nm). Type Unfasten the front cover and place a 4 mm hex screwdriver on the red actuating shaft. 2. Retract the actuator stem by turning the screwdriver counterclockwise only and only until the travel final value is reached, at the maximum, which activates the bottom torque switch. Note! Do not turn the actuator stem too far, otherwise it will be ruined. 3. Hold the screwdriver in place. Secure the actuator and connection piece with the coupling nut (tightening torque: 20 Nm). 4. Remove screwdriver and carefully refasten the front cover. 3.4 Type /-21 Actuators 1. Place the actuator with its yoke on the valve bonnet and fasten tight with hexagon nut. 3. Position both clamps of the stem connector over the ends of the actuator and plug stems. Secure stem connector in place with two hexagon head screws. 3.5 Type /-2 Actuators 1. Apply signal pressure to the loading pressure connection of actuator with fail-safe action Actuator stem extends (see section 5) to retract the actuator stem. 2. Place the actuator on the connection piece and secure with the coupling nut (tightening torque: 20 Nm). 3.3 Type 3274 and Type Actuators 1. Place the actuator on the valve yoke and secure with ring nut. 2. Position both clamps of the stem connector over the ends of the actuator and plug stems. Secure stem connector in place with two hexagon head screws. 3. Move the actuator to its end position (see section 6) and align the travel indicator with the tip of the stem connector. 12 EB 5868/5869 EN
13 Electrical connections 4 Electrical connections Upon installing the electrical cables, you are required to observe the regulations concerning electrical power installations according to DIN VDE 0100 as well as the regulations of your local power supplier. Use a suitable power supply to ensure that no dangerous voltages from the system or parts of the system reach the device in standard operation or in case of a fault. Warning! Only connect the device to the main power network when the power is switched off. Make sure the power cannot be switched on unintentionally! 4.1 Type 5857 Electric Actuator 1. Connect the power supply over the 2.5 m cable. The control signals of the connected controllers are connected to the terminals el and al: If a voltage is applied to el, the actuator stem retracts into the actuator (direction of action Stem retracts ). If a voltage is applied to al, the actuator stem extends out of the actuator (direction of action Stem extends ). Additional electrical equipment The actuators can be equipped with limit switches, potentiometers or with a positioner for input signals from 4 or 0 to 20 ma or alternatively 2 or 0 to 10 V. More details concerning electrical connection and operation can be found in the mounting and operating instructions of the corresponding actuators. el Actuator stem retracts al Actuator stem extends ws white br brown gr green Note! Decoupling capacitors Ce in the output circuit of the connected controller may not exceed a value of 2.5 nf in order to guarantee the proper functioning of the actuator. Fig. 3 Wiring plan of Type 5857 Electric Actuator (version with three-point stepping signal) EB 5868/5869 EN 13
14 Electrical connections 4.2 Type 5824/5825, Type 3374 Electric Actuators 1. Unfasten the housing cover. 2. Guide the connecting wires through the cable entries and fasten them to the terminals. The control signals of the controller are connected to the terminals el and al: If a voltage is applied to el, the motor retracts the actuator stem. If a voltage is applied to al, the motor extends the actuator stem. Actuators operated in parallel must be controlled over separate contacts since the use of just one common open and closed contact could cause the actuators to hunt in the final positions. 3. For the Type 5825 and Type x Actuators with fail-safe action, the terminals L and N must additionally be supplied with a voltage. When the voltage supply is interrupted, the control valve remains in the final position determined by the fail-safe action (actuator stem extends, valve closed). 4. Refasten the housing cover. Controller Type 5824/5825 el Actuator stem retracts al Actuator stem extends Magnet in Type 5825 with safety function Type 3374 Limit switches Potentiometer for Type 3374 Potentiometer Type 5824/5825 Note! Decoupling capacitors Ce in the output circuit of the connected controller may not exceed a value of 2.5 nf in order to guarantee the proper functioning of the actuator. Fig. 4 Wiring plan of Type 5824/5825 and Type 3374 (version with three-point stepping signal) 14 EB 5868/5869 EN
15 Electrical connections 4.3 Type 3274 Actuator 1. Unscrew the housing cover at the side. 2. Lead the lines through the cable glands on the housing to the terminals. The N and L terminals must be continuously supplied with a voltage, otherwise the actuator will remain in its last position. Actuators with safety function move to the fail-safe position 3. Connect the grounding conductor to the separate grounding terminal on the inside wall of the housing. 4. Screw the housing cover at the side back on. Heating resistor Stem retracts Stem extends Controller Safety interlock circuit, only with Type x Note! The controller output relay to control the input signals al (actuator stem extends) and el (actuator stem retracts) should only be connected over the terminal 81 (same potential). Fig. 5 Wiring plan of Type 3274 Electric Actuator (version with three-point stepping signal) EB 5868/5869 EN 15
16 Pneumatic connection of Type /-2 Actuators 5 Pneumatic connection of Type /-2 Actuators Type Connect the signal pressure to actuators with Actuator stem retracts (FA) to loading pressure connection (3): When the signal pressure is reduced or upon supply air failure, the springs move the actuator stem downwards, causing the valve to close. Connect the signal pressure to actuators with Actuator stem extends (FE) to loading pressure connection (4): When the signal pressure is reduced or upon supply air failure, the springs move the actuator stem upwards, causing the valve to open. 2. Screw the vent plug in the opposite connection which is not used. Type Actuator stem extends retracts 3 Loading pressure connection: Stem extends 4 Loading pressure connection: Stem retracts Type The Type Actuator is designed for integral attachment of a positioner. The signal pressure is routed to the diaphragm chamber by the switchover plate attached to the left or right side of the yoke. The fail-safe position required determines how the positioner is attached and how the switchover plate is positioned. If the actuator is operated without a positioner, a connecting plate must be used instead of the switchover plate. Refer to EB 5840 EN for details on how to connect the pneumatic actuator. Type Actuator stem extends retracts 10 Switchover and connecting plate 10.1 Signal pressure input: Actuator stem extends 10.2 Signal pressure input: Actuator stem retracts Fig. 6 Pneumatic connection 16 EB 5868/5869 EN
17 Operation Manual override 6 Operation Manual override 6.1 Type 5857 Actuator The plug is moved to the required position by turning the handwheel. Caution! Only activate the handwheel when the actuator is disconnected from the power supply. 6.2 Type 5824/5825 Actuators For Type 5824, the plug can be moved to the desired position by turning the handwheel. For Type 5825 with safety function, remove the front cover and place a 4 mm hex screwdriver on the actuating shaft. To move the actuator stem in the opening direction, turn the hex screwdriver only in the counterclockwise direction! Note! After the fail-safe action has been triggered by the magnet, the valve cannot be kept in position. 6.3 Type 3374 Actuator To operate the manual override, place a 4 mm Allen key on the red actuating shaft located at the side of the actuator housing. A key is delivered with the actuator and is attached to the bottom of the actuator housing. The manual override of actuators with safety function only functions when the power supply (terminals N and L) is connected. Note! After the fail-safe action has been triggered by the magnet, the valve cannot be kept in position. 6.4 Type 3274 Actuator Version with mechanical override Type /-16 Press the black button on top of the actuator. Place a socket wrench (24 mm) on the shaft end of the rack-and-pinion drive protruding from the housing and turn it until the required valve position is reached. As soon as the button is released, the actuator operates according to the controller signal again. If the valve is to remain in the manually adjusted position, the terminal 81 must be disconnected as described in section Note! A hydraulic actuator can move its position even when it is switched off due to external or internal forces (springs) caused by leakages inside the actuator. This should be taken into account in cases where a valve is to be kept open. EB 5868/5869 EN 17
18 Operation Manual override Version with electric override Type The actuator stem can be either retracted or extended by pressing one of the two pushbuttons located on the side cover to bring the attached valve into the required position. After releasing the button, the actuator uses the controller signal again. To deactivate, for example, the priority of the control signal during start-up of the plant and to keep control valve in a certain position, the terminal 81 must be disconnected as described in section The red marking pin is no longer visible. Refasten cover and switch on power. The control signal is now interrupted and the valve can be moved to the desired position by pressing the pushbutton IN or OUT. The valve will then remain in the adjusted position. If the control signal of the controller should have priority again: Switch off power and remove cover. Firmly press the button until it engages and the red pin becomes visible again. Refasten cover and switch on power Disconnect terminal Switch off power! 2. Undo the two fastening screws on the side housing cover and remove cover. 3. Place a screwdriver at the terminal 81 under the white button and lever up button until it engages. Connect terminal Button Button IN Marking pin Red marking pin Disconnect terminal Terminal Button OUT Fig. 7 Terminal (81) and button for manual override 18 EB 5868/5869 EN
19 Maintenance 7 Maintenance The control valves are subject to natural wear. Depending on the conditions the valves are operated in, they need to be checked at regular intervals. If leakage to the atmosphere occurs, it may be due to a defective packing or balancing bellows. If the valve does not seal properly, the tight shut-off may be impeded by dirt or other impurities caught between the seat and plug, or by damaged seat facing. Remove the parts, clean them thoroughly and replace them, if necessary. Warning! For maintenance work on the valve, make sure the relevant section of the pipeline is depressurized and, depending on the process medium, drained as well. For high medium temperatures, allow the section of the pipeline to cool down before you start. Make sure the supply pressure or electric power supply and control signals are interrupted or blocked to prevent any risks from moving parts at the control valve. As valves are not free of cavities, there might still be residual medium in the valve. This applies, in particular, for valve versions with balancing bellows. We recommend removing the valve from the pipeline. EB 5868/5869 EN 19
20 20 EB 5868/5869 EN
21 Dimensions in mm and weights 8 Dimensions in mm and weights Actuators mounted on Type 3213 Globe Valves DN Actuators mounted on Type 3213 Globe Valve Length L Height H Height H Type 3213/ Type 3213/5824 Type 3213/ Type 3213/ Weight, approx. kg (version for steam kg) Type 3213/ Type 3213/5824 Type 3213/ Type 3213/ Type 3213/ Type 3213/5857, DN 15 to 25 Type 3213/5824 Type 3213/5825; DN 15 to 50 Type 3213/2780-1, DN 15 to 50 Type 3213/2780-2, DN 15 to 50 Insulating section or intermediate piece for steam version EB 5868/5869 EN 21
22 Dimensions in mm and weights Actuators mounted on Type 3214 Globe Valves DN Actuators mounted on Type 3214 Globe Valves Length L Height H Height H Type 3214/ Type 3214/ Type 3214/ Type 3214/3274 1) Height H Height H3 Type 3214/3374 H mm Type 3214/3274 1) Weight, approx. kg (version for steam or with insulating section kg Version for PN 25 and PN %) Type 3214/ Type 3214/ Type 3214/ Type ) Add 95 mm to the H and H3 dimensions for Type and Type Actuators. 22 EB 5868/5869 EN
23 Dimensions in mm and weights Type 3214/5824 Type 3214/5825, DN 15 to 50 Type 3214/3374, DN 65 to 100 Type 3214/2780-2, DN 65 to _ > H3 H 110 M 30x1.5 H1 H2 L Type 3214/3274, DN 125 to 250 Type 3214/3374, DN 125 to 250 EB 5868/5869 EN 23
24 SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße Frankfurt am Main Germany Phone: Fax: Internet: EB 5868/5869 EN
Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve
Series V2001 Valves Type 3321 Globe Valve Type 3321 Globe Valve with rod-type yoke and Type 3372 Electropneumatic Actuator (350 cm²) Mounting and Operating Instructions EB 8111/8112 EN Edition June 2013
More informationTypetested versions With Type 3213 Globe Valve, unbalanced. With Type 3214 Globe Valve, balanced
Electric Control Valves/Controller with Electric Actuator with safety function, typetested Types 3213/5725, 3214/5725 Single-seated Globe Valve Type 3213, unbalanced Single-seated Globe Valve Type 3214,
More informationMounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump
Electric control valves with jet pump Type 3267/5824, Type 3267/5825, Type 3267/3374, Type 3267/3274 Pneumatic control valves with jet pump Type 3267-1, Type 3267-7 Flanged version of valve with jet pump
More informationMounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve
Electric Control Valves Types 3226/5857, 3226/5824, 3226/5825, 3226/5757-7, 3226/5724-8, 3226/5725-7, 3226/5725-8 Pneumatic Control Valve Type 3226/2780 Type 3226/5857 Type 3226/5757-7 Type 3226/2780-2,
More informationMounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321
Valve Series V2001 Globe Valve Type 3321 Fig. 1 Type 3321 Valve with mounted rod-type yoke for pneumatic or electric actuators (partial view) Mounting and Operating Instructions EB 8111/8112 EN Edition
More informationGlobe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN
Globe Valve Type 3241 Fig. 1 Type 3241 Globe Valve Mounting and Operating Instructions EB 8015-1 EN Edition July 2012 Contents Contents Page 1 Design and principle of operation.................... 4 2
More informationMounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type
Pneumatic Control Valves Type 3347-1 and Type 3347-7 Hollow-mold cast body with welding ends Full-mold cast body with threaded connections Fig. 1 Type 3347-7 Control Valve with Type 3277 Actuator and integral
More informationMounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator
Pneumatic Control Valve Type 3510-1 and Type 3510-7 Type 3510-1 with 120 cm 2 actuator Type 3510-7 with 120 cm 2 actuator and integrated positioner Type 3510-1 with 60 cm 2 actuator Fig. 1 Pneumatic control
More informationValve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator
Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam Nominal size
More informationMounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves
Series 250 Type 3252 1 and Type 3252 7 Pneumatic Control Valves Type 3252 High-pressure valve with Type 3277 Pneumatic Actuator and Type 3767 Electropneumatic Positioner Mounting and Operating Instructions
More informationMounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil
Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Type 3535 Three-way Valve with bellows seal and rod-type yoke (partial view) Mounting and Operating Instructions EB 8135/8136 EN Edition
More informationMounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve
Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal
More informationMounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve
Type 3249-1 and Type 3249-7 Pneumatic Control Valves Type 3249 Aseptic Angle Valve Ball body version Special version with packing Type 3249-7 Control Valve with Type 3277 Actuator and integrated positioner
More informationSeries 250 Pneumatic Control Valves Type and
Series 250 Pneumatic Control Valves Type 3252-1 and 3252-7 Fig. 1 Type 3252 High-pressure Valve with Type 3277 Pneumatic Actuator and Type 3767 i/p Positioner Edition November 1998 Mounting and operating
More informationMounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves
Type 3347-1 and Type 3347-7 Pneumatic Control Valves Type 3347-7, cast body with welding ends Type 3347-7, bar stock body with threaded connections Mounting and Operating Instructions EB 8097 EN Edition
More informationSeries V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator DIN version Application Control valves for heat transfer applications using organic media according to
More informationMounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)
Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator) Linear Actuator with Type 3260 Control Valve Rotary actuator with lever system Linear actuator with Type 3321 (V2001) Control
More informationMounting and operating instructions EB 8093 EN. Series 240 Pneumatic Control Valve for Cryogenic Temperatures. Type and
Series 240 Pneumatic Control Valve for Cryogenic Temperatures Type 3248-1 and 3248-7 Fig. 1 Type 3248 Cryogenic Valve with Type 3277 Pneumatic Actuator as globe and angle valve Mounting and operating instructions
More informationMounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve
Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278 Type 3331 Butterfly Valve Fig. 1 Type 3331/BR 31a (below) and Type 3331/3278 (top) Mounting and Operating Instructions EB 8227 EN
More informationSeries 240 Type Gas and Type Gas Automatic Shut-off Valves for Gases (valve class D)
Series 240 Type 3241-1-Gas and Type 3241-7-Gas Automatic Shut-off Valves for Gases (valve class D) DIN-DVGW typetested acc. to DIN EN 161 (2013-04) Application Control valve for control systems subject
More informationTypetested for liquid fuels and liquefied petroleum gas (LPG) in the liquid phase (see Data Sheet T 8022 EN) Version according to ANSI standards
Series 240 Pneumatic Control and Quick-acting Shut-off Valves for gases Type 3241-1-Gas and Type 3241-7-Gas DIN-DVGW typetested acc. DIN EN 161 (1996-08) Application Control valves for control equipment
More informationSeries V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator ANSI version Application Control valves for heat transfer applications using organic media according
More informationSeries 240 Electric Control Valve Type 3241/3274 Globe Valve Type 3241 Electric Control Valve Type 3244/3274 Three-way Valve Type 3244
Series 240 Electric Control Valve Type 3241/3274 Globe Valve Type 3241 Electric Control Valve Type 3244/3274 Three-way Valve Type 3244 Application Versatile control valves with globe or three-way valve
More informationMounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve
Type 3310/AT and Type 3310/3278 Pneumatic Control Valves Type 3310 Segmented Ball Valve Fig. 1 Type 3310/3278 with positioner Fig. 2 Type 3310/AT Mounting and Operating Instructions EB 8222 EN Edition
More informationSeries 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve
Series 240 Type 3248-1 and Type 3248-7 Pneumatic Control Valves Type 3248 Cryogenic Valve ANSI version Application Globe or angle valve for cryogenic applications Easy to service due to top-entry design
More informationSeries 240 Type and Type Pneumatic Control Valves Type 3248 Cryogenic Valve
Series 240 Type 3248-1 and Type 3248-7 Pneumatic Control Valves Type 3248 Cryogenic Valve ANSI version Application Globe or angle valve for cryogenic applications Easy to service due to top-entry design
More informationSeries V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator DIN version Application Mixing or diverting valves for heat transfer applications using organic media
More informationSeries 42 Self-operated Regulators. Type RS Check Valve (backflow protection)
Series 42 Self-operated Regulators Type 42-10 RS Check Valve (backflow protection) Application Designed to protect nitrogen and compressed air networks against backflow from directly connected systems.
More informationANSI version. The valve closes when the differential pressure rises
Self-operated Regulators Series 42 Differential Pressure Regulator with Type 2424/Type 2428 Actuator and Type 2422 Valve Type 42-24 A Type 42-24 B Type 42-28 A Type 42-28 B ANSI version Application For
More informationEB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions
EB 8313-1 EN Translation of original instructions V2001-IP Control Valve Type 3372 0511/0531 Electropneumatic Actuator with Type 3321 Valve Type 3372 Electropneumatic Actuator Edition July 2013 Note on
More informationSeries 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241
Series 240 Pneumatic Control Valve Type 3241-1 and Type 3241-7 Globe Valve Type 3241 Application Control valve for process engineering and industrial applications Nominal size DN 15 to 300 Nominal pressure
More informationValve Series V2001 Three-way Valve Type 3323
Valve Series V2001 Three-way Valve Type 3323 Fig. 1 Type 3323 Valve with mounted rod-type yoke (partial view) Edition January 1999 Mounting and operating instructions E 8113/8114 EN 1. Design and principle
More informationSeries V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator ANSI version Application Mixing or diverting valves for heat transfer applications using organic
More informationSeries 240 Pneumatic Control Valve Type and Type Three-way Valve Type 3244
Series 240 Pneumatic Control Valve Type 3244-1 Type 3244-7 Three-way Valve Type 3244 with long insulating section circulation inhibitor ANSI version Application Mixing or flow-diverting valve for cryogenic
More informationSeries W&T Pneumatic Control Valve Type RVG Globe valve and angle valve
Series W&T Pneumatic Control Valve Type RVG Globe valve and angle valve Application Control valve for feedwater and steam applications in power plant engineering and the petrochemical industry Nominal
More informationMounting and operating instructions EB Pneumatic Control Valve Type and Type Globe Valve Type 3522 ANSI Class 300
Pneumatic Control Valve Type 3522-1 and Type 3522-7 Globe Valve Type 3522 ANSI Class 300 Fig. 1 Type 3522-7 Control Valve with integrated positioner Mounting and operating instructions EB 8822 Edition
More informationSeries 240 Pneumatic On-off Valve Type 3351
Series 240 Pneumatic On-off Valve Type 3351 Application Control valve with a tight shutoff of liquids, gases and steam in accordance with DIN or ANSI standards Nominal sizes DN 15 to 100 NPS ½ to 4 Nominal
More informationPneumatic Shut-off Butterfly Valve Type 3335/BR 31a
Pneumatic Shut-off Butterfly Valve Type 3335/BR 31a Application Tight-closing butterfly valve for process engineering and plants with industrial requirements DN 50 to DN 300 2 to 12 Nominal pressure PN
More informationSeries 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241
Series 240 Pneumatic Control Valve Type 3241-1 and Type 3241-7 Globe Valve Type 3241 Application Control valve for process engineering and industrial applications Nominal size 15 to 300 Nominal pressure
More informationMounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type
Electropneumatic Converters i/p Converter Type 3913-0001 Fig. 1 Type 3913-0001 Electropneumatic Converter with pressure gauge and bracket Mounting and Operating Instructions EB 3913 EN Edition August 2011
More informationSelf-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 ANSI version Application Pressure regulators for set points from 0.075 to 400 psi (5 mbar to 28 bar) Valves in NPS ½ to 4
More informationSeries 250 Pneumatic Control Valve Type and Type High Pressure Valve Type 3252
Series 250 Pneumatic Control Valve Type 3252-1 and Type 3252-7 High Pressure Valve Type 3252 Application Control valve used control small flow rates in process engineering Nominal size G 1 2 1 NPT 1 2
More informationSelf-operated Pressure Regulators Type Universal Excess Pressure Valve
Self-operated Pressure Regulators Type 41-73 Universal Excess Pressure Valve Application Pressure regulators for set points from 0.05 to 8 bar Valve nominal sizes DN 15 to 100 Nominal pressure PN 16 to
More informationMounting and operating instructions EB EN. Differential Pressure and Temperature Regulator with Flow Limiter Type 2479/2430 K
Differential Pressure and Temperature Regulator with Flow Limiter Type 2479/2430 K Special version DN 15 with differential pressure set point p = 0.5 bar Fig. 1 Type 2479/2430 K Mounting and operating
More informationSelf-operated Pressure Regulators Type Universal Excess Pressure Valve
Self-operated Pressure Regulators Type 41-73 Universal Excess Pressure Valve ANSI version Application Pressure regulator for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN 15
More informationElectropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN
Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions
More informationPressure Reducing Valve Type 2114/2415
Pressure Reducing Valve Type 2114/2415 Fig. 1 Type 2114/2415 1. Design and principle of operation The Type 2114/2415 Pressure Reducing Valve consists of the Type 2114 Valve and the Type 2415 Actuator.
More informationSeries 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244
Series 240 Pneumatic Control Valves Type 3244-1 and Type 3244-7 Three-way Valve Type 3244 DIN and ANSI versions Applications Mixing or flow-diverting valves for use in process engineering and industrial
More informationSelf-operated Temperature Regulators Temperature Regulator Type 1u
Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points from 0 to 250 C G ½ to G or DN 5 to DN
More informationSelf-operated Temperature Regulators Type 1u Temperature Regulator
Self-operated Temperature Regulators Type 1u Temperature Regulator ANSI version Application Temperature regulators for cooling installations Control thermostats for set points 1) from 15 to 480 F ( 10
More informationType 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN
Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators Fig. 1 Type 3761 Positioner Mounting and Operating Instructions EB 8386 EN Edition July 2007 Contents Contents Page 1 Design and
More informationPneumatic Control Valve Type and Type Micro-flow Valve Type 3510
Pneumatic Control Valve Type 3510-1 and Type 3510-7 Micro-flow Valve Type 3510 ANSI version Application Control valve designed for controlling low flow rates in pilot plants and technical research facilities.
More informationSeries 240 Type 3351 Pneumatic On/off Valve
Series 240 Type 3351 Pneumatic On/off Valve Application Shut-off valve with tight shut-off for liquids, gases and vapors according to DIN or ANSI standards Valve size DN 15 to 100 NPS ½ to 4 Pressure rating
More informationPneumatic Butterfly Valve Type 3335 / AT
Pneumatic Butterfly Valve Type 3335 / AT Application Tight closing butterfly valve for process engineering and plants with industrial requirements DN 50 to DN 300 2 to 12 Nominal pressure PN 10 and PN
More informationPneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN
Pneumatic or Electropneumatic Positioner for Rotary Actuators Type 3761 Fig. 1 Type 3761 Positioner Mounting and Operating Instructions EB 8386 EN Edition June 2004 Contents Contents Page 1 Design and
More informationT 8053 EN Type and Type Pneumatic Control Valves Type 3252 High-pressure Valve
T 8053 EN Type 3252-1 and Type 3252-7 Pneumatic Control Valves Type 3252 High-pressure Valve Application Control valve especially designed for controlling low flow rates in process engineering Valve sizes
More informationType 3273 Hand-operated Actuator Type 3273 Side-mounted Handwheel
Type 3273 Hand-operated Actuator Type 3273 Side-mounted Handwheel Application Hand-operated actuator or side-mounted handwheel for mounting on control valves, especially Series 240, 250, 260 ), 280 and
More informationSeries 240 Pneumatic Control Valve Type DWA, -7 DWA, -9 DWA Globe Valve Type 3241 DWA
Series 240 Pneumatic Control Valve Type 3241-1 DWA, -7 DWA, -9 DWA Globe Valve Type 3241 DWA ANSI version Application Control valve for PSA plants (Pressure Swing Adsorption) (German: DWA) NPS ½ to 6 Pressure
More informationSelf-operated Pressure Regulators Type Universal Pressure Reducing Valve
Self-operated Pressure Regulators Type 41-23 Universal Pressure Reducing Valve ANSI version Application Pressure regulators for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN
More informationSelf-operated Temperature Regulators Type 1u Temperature Regulator
Self-operated Temperature Regulators Type 1u Temperature Regulator Version according to ANSI Application Temperature regulators for cooling plants Control thermostats for set points 1) from 15 to 480 F
More informationSeries 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve
Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve DIN and ANSI versions Application Mixing or diverting valve for process engineering and industrial applications
More informationData Sheet T EN
Data Sheet T 8015-1 EN Series 240 Types 3241 1 PSA, -7 PSA, -9 PSA Pneumatic Control Valves Type 3241 PSA Globe Valve Application Control valves for PSA plants (Pressure Swing Adsorption) Valve sizes DN
More informationIn combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator
Type 3510 Micro-flow Valve In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator DIN version Translation of original instructions Type 3510-1 (left) and Type 3510-7 (right)
More informationType 3271 Pneumatic Actuator. Actuator area: cm². Mounting and Operating Instructions EB EN
Type 3271 Pneumatic Actuator Actuator area: 1400-60 cm² Mounting and Operating Instructions EB 8310-3 EN Edition January 2014 Definition of the signal words used in these mounting and operating instructions
More informationSeries 240 Type and Type Pneumatic Control Valves Type 3347 Hygienic Angle Valve
Series 240 Type 3347-1 and Type 3347-7 Pneumatic Control Valves Type 3347 Hygienic Angle Valve Application Control valve for hygienic applications in the food and pharmaceutical industries Valve size DN
More informationSeries 3331 Pneumatic Control Butterfly Valve Type 3331/BR 31a
Series 3331 Pneumatic Control Butterfly Valve Type 3331/BR 31a Application Control butterfly valve for use in process engineering and industrial applications to meet high demands Suitable for liquids,
More informationSeries V2001 Valves Clean Tech Type 3321CT Globe Valve with pneumatic actuator
Series V2001 Valves Clean Tech Type 3321CT Globe Valve with pneumatic actuator DIN version Application Compact control valve for the process industry Valve size DN 15 to 50 Pressure rating PN 16 to 40
More informationStrainers with flanged connections Type 2 N Type 2 NI. Type 2 N/2 NI Strainers. Mounting and Operating Instructions EB 1015 EN
Strainers with flanged connections Type 2 N Type 2 NI Type 2 N/2 NI Strainers Mounting and Operating Instructions Edition June 2014 Definition of signal words DANGER! Hazardous situations which, if not
More informationIn combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator
Type 3510 Micro-flow Valve In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator ANSI version Translation of original instructions Type 3510-1 (left) and Type 3510-7
More informationType and Type Pneumatic Control Valves Type 3510 Micro-flow Valve
Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve ANSI version Application Control valve especially designed for controlling low flow rates in pilot plants and technical research
More informationMounting and Operating Instructions EB EN. Type 3372 Electropneumatic Actuator. Actuator area: 120 and 350 cm² With Type 3725 Positioner
Type 3372 Electropneumatic Actuator Actuator area: 120 and 350 cm² With Type 3725 Positioner Translation of original instructions Type 3372 with 120 cm² actuator area Type 3372 with 350 cm² actuator area
More informationCombined Self-operated Regulators Regulators for Differential Pressure, Flow Rate and Temperature
Combined Self-operated Regulats Regulats f Differential Pressure, Flow Rate and Temperature Application Regulats f district heating supply netwks, heat generats, heat exchangers, building service plants
More informationSeries 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6
Series 46 Self-operated Regulators Differential Pressure and Flow imiters Type 46-5 Type 46-6 Application Differential pressure and flow limitation for district heating systems with indirect connection,
More informationSeries 240 Types PSA, -7 PSA, -9 PSA Pneumatic Control Valves Type 3241 PSA Globe Valve
Series 240 Types 3241-1 PSA, -7 PSA, -9 PSA Pneumatic Control Valves Type 3241 PSA Globe Valve ANSI version Application Control valves for PSA plants (Pressure Swing Adsorption) s NPS ½ to 6 Pressure rating
More informationSystem 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126
System 6 Electropneumatic Converter for Direct Current Signals i/p Converter Type 66 Application Devices used to convert a direct current signal into a pneumatic signal for measurement and control. Especially
More informationSolenoid Valves Type 3963
Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate
More informationMaxifluss Rotary Plug Valve. VETEC Type 72.1/R, Type 72.3/R and Type 72.4/R
Maxifluss Rotary Plug Valve VETEC Type 72.1/R, Type 72.3/R and Type 72.4/R Application Double eccentric control valve for process engineering and plants with industrial requirements Nominal size DN 25
More informationSeries 240 Type 3349/3379 Pneumatic Control Valve Type 3349 Aseptic Angle Valve
Series 240 Type 3349/3379 Pneumatic Control Valve Type 3349 Aseptic Angle Valve With USP-VI diaphragm Application Control valve for aseptic applications in the food and pharmaceutical industries DIN or
More informationLimit Switch Type 3776
Mounting and Operating Instructions Limit Switch Type 3776 Fig. 1 Edition: June 2014 EB 8368 EN Contents General notes 3 Model number and device index 3 Mounting 3 Mounting to SAMSON Type 3278 Rotary Actuators
More informationType 3379 Pneumatic Actuator. Mounting and Operating Instructions EB 8315 EN
Type 3379 Pneumatic Actuator Mounting and Operating Instructions EB 8315 EN Edition October 2014 Definition of signal words DANGER! Hazardous situations which, if not avoided, will result in death or serious
More informationPneumatic Butterfly Valve Pfeiffer Type BR 14b/AT
Pneumatic Butterfly Valve Pfeiffer Type BR 14b/AT Application Tight closing, double eccentric butterfly valve for process engineering and plants with industrial requirements Nominal size DN 80 to DN 400
More informationSeries 3730 Electropneumatic Positioner Type
Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and
More informationType 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175 and 750 cm². Type 3271 Type Mounting and Operating Instructions EB EN
Type 3271 and Type 3277 Pneumatic Actuators Actuator areas: 175 and 750 cm² Type 3271 Type 3277 Type 3271 and Type 3277 Pneumatic Actuators Mounting and Operating Instructions EB 8310-5 EN Edition October
More informationType 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN
Type 3768 Inductive Limit Switch Mounting and Operating Instructions EB 8356 EN Edition February 2013 Note on these mounting and operating instructions These mounting and operating instructions (EB) assist
More informationT EN Type 3347/3379 Pneumatic Control Valve Type 3347 Hygienic Angle Valve
T 8097-3 EN Type 3347/3379 Pneumatic Control Valve Type 3347 Hygienic Angle Valve Application Control valve for hygienic applications in the food and pharmaceutical industries Valve size DN 6 to NPS ¼
More informationSTEVI 450 / way control valve in mixing and diverting design DN
STEVI 450 / 451 with electric and pneumatic actuators 3-way control valve in mixing and diverting design DN 15-150 STEVI 450 / 451 Electric actuator ARI-PREMIO Enclosure IP 65 2 torque switches 1 travel
More informationLined Butterfly Valve Pfeiffer Type BR 10a
Lined Butterfly Valve Pfeiffer Type BR 10a Application Tight closing, double eccentric butterfly valve with PTFE lining for process engineering and plants with industrial requirements, especially suitable
More informationPneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN
Pneumatic Controller for Temperature Type 3301 Pneumatic Controller for Temperature Type 301-1 Mounting and Operating Instructions EB 7065 EN Edition January 2014 Definition of the signal words used in
More informationPneumatic Control Valve Assembly Type 3331/3278
Pneumatic Control Valve Assembly Type 3331/3278 Fig. 1 Type 3331/3278 Pneumatic Control Valve Assembly 1. Design and principle of operation The pneumatic control valve assembly consists of a Type 3331
More informationT EN Type 3349 Aseptic Angle Valve With USP-VI diaphragm
T 8048-2 EN Type 3349 Aseptic Angle Valve With USP-VI diaphragm Application Control valve for aseptic applications in the food and pharmaceutical industries according to DIN or ANSI standards with USP-VI
More informationType 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN
Type 3768 Inductive Limit Switch Mounting and Operating Instructions EB 8356 EN Edition February 2013 Note on these mounting and operating instructions These mounting and operating instructions (EB) assist
More informationIn combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator
Type 3244 Valve In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator DIN and ANSI versions Translation of original instructions Type 3244 Valve with Type 3271 Actuator
More informationARI-STEVI 470 / 471 (DN15-150)
With pneumatic and electric actuators ARI-STEVI 470 / 471 (DN15-150) Control valve - straight through with screwed seat ring, shaftguided plug and blow-out protected stem ARI-STEVI 470 / 471 Pneumatic
More informationMounting and Operating Instructions EB 8256 EN. Type 3286 Steam Conditioning Valve
Type 3286 Steam Conditioning Valve In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator DIN version Translation of original instructions Mounting and Operating Instructions
More informationMaxifluss Rotary Plug Valves VETEC Types 72.3/R and 72.4/R
Maxifluss Rotary Plug Valves VETE Types 72.3/R and 72.4/R Application Double-eccentric control valve for process engineering and industrial applications Nominal sizes DN 25 to 400 NPS 1 to 1 Nominal pressures
More informationIn combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator
Type 3241 Valve In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator ANSI and JIS version Translation of original instructions Type 3241 Valve with Type 3271 Actuator
More informationType 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN
Type 3571 Pneumatic Actuator Actuator areas: 27 in² 54 in² 116 in² Original instructions Mounting and Operating Instructions Edition April 2016 Note on these mounting and operating instructions These mounting
More informationSystem 6000 Electropneumatic Converters for DC ranges I/P Converter Type 6102 Type 5288
System 6000 Electropneumatic Converters for DC ranges I/P Converter Type 6102 Type 5288 Fig. 1 Type 6102-51 Rack-mounting Unit Fig. 2 Type 6102-52 Rack-mounting Unit Fig. 3 Type 6102-53 Field Unit Fig.
More informationVersions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve
Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE
More informationMounting and Operating Instructions EB 8052 EN. Type 3251 Valve
Type 3251 Valve In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator ANSI version Translation of original instructions Type 3251 Valve with Type 3271 Actuator Mounting
More information