WESAN WP WOLTMAN METER
|
|
- Katrina Hart
- 6 years ago
- Views:
Transcription
1 WESAN WP WOLTMAN METER APPLICATION The bulk water meter WESAN WP can be used for measuring volumes of cold water (up to 50 C) in supply lines with high flow at low pressure loss. The measuring chamber can be replaced without removing the meter from the pipe. Equiped with a rotating glass metal register as standard, WESAN WP can be fitted with different pulse emitters. FEATURES 4 For horizontal and vertical installation 4 Removeable measuring insert 4 Sealed measuring insert for better accuracy 4 Encapsulated and rotating counter of glass/copper IP68 4 Integrated measurement outputs as standard 4 Sensors for remote readout (digital) and flow measurement (analogue)
2 WESAN WP WOLTMAN METER GENERAL WESAN WP Medium temperature range C Maximum media temperature range C Ambient operating temperature C Ambient storage temperature C Protection class IP 68 TECHNICAL DATA Nominal diameter DN mm Nominal flow rate (DIN ISO 4064) Q n m³/h Permissible continuous load (HY) Q n m³/h Maximum flow rate (short-term) Q max m³/h Transition flow rate horizontal Q t m³/h Transition flow rate vertical Q t m³/h Minimum flow rate horizontal Q min m³/h Minimum flow rate vertical Q min m³/h Starting flow rate l/h Flow rate at 0.1 bar pressure loss m³/h Nominal pressure PN bar / Nominal diameter DN mm Nominal flow rate (DIN ISO 4064) Q n m³/h Permissible continuous load (HY) Q n m³/h Maximum flow rate (short-term) Q max m³/h Transition flow rate horizontal Q t m³/h Transition flow rate vertical Q t m³/h Minimum flow rate horizontal Q min m³/h Minimum flow rate vertical Q min m³/h Starting flow rate l/h Flow rate at 0.1 bar pressure loss m³/h Nominal pressure PN bar / / / /
3 WESAN WP WOLTMAN METER PULSE OUTPUTS Nominal diameter DN mm Reed switch 570* - pulse value 1 l/pulse Reed switch 570* - pulse value 2 l/pulse Special pulse value l/pulse 25 / / / / / / 500 IR transmitter l/pulse Nominal diameter DN mm Reed switch 570* - pulse value 1 l/pulse Reed switch 570* - pulse value 2 l/pulse Special pulse value l/pulse 250 / / / / / 5000 IR transmitter l/pulse * For more information about reed switch 570 please have a look at the specific datasheet. DISPLAY RANGE Nominal diameter DN mm l ,999 m³ 5.0 l... 9,999,999 m³ 50 l... 99,999,999 m³ Nominal diameter DN mm l ,999 m³ 5.0 l... 9,999,999 m³ 50 l... 99,999,999 m³ APPROVAL Nominal diameter DN mm EC D 92 / D 92 / D 02 / D 02 / D 02 / D 02 / National Metrological class B H B H B B B B Nominal diameter DN mm EC D 02 / National / / / / Metrological class B B B B B
4 WESAN WP WOLTMAN METER DIMENSIONS Nominal diameter DN mm Overall length L mm / Flange diameter D mm Hole circle diameter PN 10 / PN 16 K mm - / / / / / / 240 Number of screwholes PN 10 / PN 16 pcs - / 4 - / 4 4 / 8 - / 8 - / 8 - / 8 Screwhole diameter PN 10 / PN 16 D1 mm - / 18 - / / 18 - / 18 - / 18 - / 22 Height H mm Height H1 mm Height to remove measuring insert mm Meter width mm Diameter Ø B mm Weight kg Nominal diameter DN mm Overall length L mm Flange diameter D mm Hole circle diameter PN 10 / PN 16 K mm 295 / / / / / 650 Number of screwholes PN 10 / PN 16 pcs 8 / / / / / 20 Screwhole diameter PN 10 / PN 16 D1 mm 22 / / / / / 33 Height H mm Height H1 mm Height to remove measuring insert mm Meter width mm Diameter Ø B mm Weight kg
5 WESAN WP WOLTMAN METER SPECIAL VERSIONS - High-pressure version up to 25/40 bar - Flange for ANSI and BS - CuZn parts in V2A - Temperature up to 90 C - Different pulse outputs PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph
6 WATER SUPPLY MANAGEMENT FOR IMPROVEMENT OF TECHNICAL SKILL AND KNOWLEDGE OF LOCAL WATER SUPPLY UTILITIES IN NEPAL DECEMBER 2012 By Visoth CHEA, PhD Deputy General Director
7 Visoth CHEA, PhD Deputy General Director
8
9
10 C1 C2 NRW vs. Revenue Total NRW = PO ( C i ) Plant Output Z1 Z2 Z3 C3 TM NRW = PO - ( Z i ) Zone i NRW = Z i ( C i ) C6 C5 C4
11
12 Single Jet (velocity) Dry Magnetic coupling Water condense Multi Jet (velocity) Dry Magnetic coupling Water condense
13 Oscillating piston (volumetric) Dry Magnetic coupling Water condense Wet Dry Wet
14 Woltman (velocity) Horizontal Vertical Dry Magnetic coupling
15 Compound
16 Meter Class : D, C, B, A (ISO 4064)
17 Meter Class : D, C, B, A (ISO 4064)
18 Meter Class : D, C, B, A (ISO 4064)
19 Meter Class : D, C, B, A (ISO 4064)
20 ACCURATE = Real Error (E) Acceptable Error (±5 or 2%) V Meter E (%) = 100 x (V M V T ) / V T V Tank Real Volume
21
22 Meters Installation - Singapore
23 Meters Installation - Australia
24 Meters Installation - Philippines
25 Meters Installation
26 1
27 2
28 3
29 4
30 5
31 6
32 ACCURATE = Real Error (E) Acceptable Error (±5 or 2%) V Meter E (%) = 100 x (V M V T ) / V T V Tank Real Volume 7
33 Level Flow Meter Scale Tank Water Main 8
34 nalikaekal Master Meter v:an Valve v:an Valve nalikabinitü Tested Meter v:an Valve 9
35 10
36 Singapore 11
37 Japan 12
38 13
39
40
41 ~ Qmin ~ Qmax
42 15mm 20mm 25mm 30mm 40mm E % Q (m 3 /h)
43
44 16 Correlation between Qmin and Age of Water meters 12 Qmin (l/h) Age (years)
45
46 Pollutions
47
48
49
50
51
52
53
54
55
WESAN WP 222. Bulk Water Meter Woltman
APPLICATION The bulk water meter WESAN WP can be used for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. FEATURES 4 For horizontal and vertical installation
More informationDomestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features
Domestic Water Meter Elin Wasserwerkstechnik Contact Water Meter MTM for cold water Features Nominal diameter DN15 to DN50 Cold water up to 30 C (safe up to 50 C) Operating pressure up to 16 bar Control
More informationCORONA E ELECTRONIC METER MULTI-JET
APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor
More informationInstallation Instruction Bulk water meter REMOVABLE ELEMENT WOLTMAN COLD (HOT) WATER METER MODEL: LXLC-50~500
REMOVABLE ELEMENT WOLTMAN COLD (HOT) WATER METER MODEL: LXLC-50~500 LXLC(R)-50-200 LXLC(R)-250-300 APPLICATION Measuring the volume of cold (hot) water passing through the pipeline FEATURES Magnet-drive,
More informationHYDRUS ULTRASONIC METER
APPLICATION Static ultrasonic water meter for accurate measuring and recording for all applications of water supply. FEATURES 4 Real data communication, open metering telegram 4 Long-term stability under
More informationWESAN WPV E ELECTRONIC METER WOLTMAN
APPLICATION Meter for measuring heavily fluctuating flow rates. FEATURES 4 Calibratable and exchangeable measuring insert in one unit, suitable for calibration comprising: measuring insert as main meter,
More informationHYDRUS ULTRASONIC METER
HYDRUS APPLICATION Static ultrasonic water meter for accurate measuring and recording for all applications of water supply. FEATURES 4 Ultrasonic water meter with long-term stability under difficult conditions
More informationSHARKY FS 473 ULTRASONIC FLOW SENSOR
APPLICATION SHARKY FS ultrasonic flow sensor can be used for flow measuring in local and district heating / cooling systems. The measurement principle is static and based on the measurement of the transit
More informationRAY COMPACT ENERGY METER MECHANICAL
APPLICATION Fully electronic compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Highly accurate recording of all billing data in a heating
More informationCORONA ER ELECTRONIC METER MULTI-JET
APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Inbuilt radio module
More informationVZO Pressure drop curves See Meter data. Option: Reed pulser or RV / IN pulser
VZO 15...50 Technical data 1) Volume display on roller counter, in litres fuel oil meter with threaded or flanged ends for horizontal, vertical or inclined mounting Option: Reed pulser or RV / IN pulser
More informationCONTOIL VZFA/VZOA , versions for higher requirements / applications
CONTOIL VZF/VZO 4...50, versions for higher requirements / applications For applications requiring an increased accuracy of ±0.5 % or better, such as: Measurement of L heating fuel or diesel in testing
More informationVariable Area Flow Meters
JJ Series VS1 JJ Series VS3 JJ Limit switches Variable Area Flow Meters DS_Variable_Area_Flow_Meters 01/2017 185 Variable area flow meters Principle of operation Variable area flow meters are used in pipelines
More informationRAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h
APPLICATION is a fully electronic multi-jets compact heat meter or compact heat and cooling meter with impeller scanning for recording energy and volume data. is equipped with 2 temperature sensors. is
More informationVolumeter. RMG Meßtechnik GmbH. Publication No E
Volumeter TRZ 03-K RMG Meßtechnik GmbH Publication No. 3.171-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de
More informationMagnetic-inductive flow meter EPS / UMF2. Technical data sheet
Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding
More informationT O PA S Applications Features Your benefits
TOPAS Hot water Applications The TOPAS hot water meter is a velocity flowmeter based on the well-established multijet measuring principle. It operates over a wide measuring range and is used in all areas
More informationWSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.
Woltmann type combined energy meter Flanged Woltmann flow meters for large nominal flows, intended for flow measurements in large plants, such as those found in district heating systems. Size DN50 DN300
More informationWSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.
revision 04 2015 Woltmann type combined energy meter Woltmann flow meters for large nominal flows combined with calculator and temperature sensors. The WSTH and WPTH meters are designed for flow measurements
More informationResidential Water Meters
EnergyMetering Residential Water Meters Multi-jet wet dial meters Multi-jet dry dial meters Positive displacement meters AMR-technology All that counts. Technology of the highest standard Quality and reliability
More informationUS-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability
Revision 2017-08-15 Ultrasonic energy meters Flanged ultrasonic energy meters, intended for heating or cooling. Size DN25 DN100 Nominal flow 3.5 60 m³/h For horizontal or vertical mounting No data loss
More informationVZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side
VZ-01 Oil Counter for Light to Heavy Fuel Oil Description: Features / Mounting on pressure or suction side The VZ-01 series of volume counters are rotary piston meters that function without auxiliary electrical
More informationMagnetic-inductive flow meter for hazardous areas
Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials
More informationQuantometer MZ. Description
Quantometer MZ < High accuracy budget meter < Flow rate up to 10000 m 3 /h < Pressure range up to 100 bar < Equipped as standard with the cyble target. < Various options available: Low and high frequency
More informationOptions guide. Electromagnetic flowmeters. M9xx
Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910
More informationWATER METERS.
WATER METERS Design Hydrodynamic Mechanism Independent The operation of the Hydrotangential meter is based on a turbine at the top of the meter, which allows the solid particles go through without obstructing
More informationMetal tube variable area flowmeter for gases, liquids and steam
Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,
More informationN086, N186, N786. Pressure retaining valve, Plastic
Pressure retaining valve, Plastic Construction The GEMÜ N086, N186 and N786 pressure retaining valves are used to provide a constant back pressure in process plant. If the inlet pressure rises above a
More informationCOVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information
Durchflussmessung Flowmeters COVOL Areas of Application Operating Data Method of Operation Oscillating Piston Operating pressure, max. PN 10 (Plastic) PN 16 (Stainless Steel) Fields of operation Consumption
More informationAbsolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and
Pressure Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models 532.52, 532.53 and 532.54 WIKA data sheet PV 25.02 for further approvals see page 4 Applications Control
More informationBGN. All Metal Variable Area Flow Meter. Technical Data Sheet
All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of
More informationSTEEMCO Flowmeter for Steam
STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationdisplay on the wall or in a panel away from the inline sensor SE30 for easy meter reading.
Analogue Flow Rate Indicator, DN 15...; PN 1...16 Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a large
More informationVolumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas
Volumeter TRZ 0-K PRODUCT INFORMATION Reliable Measurements of Gas Method of operation, Construction Method of operation The TRZ 0-K Volumeter is a flow meter suitable for metering gases, where the rate
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS LC pressure and temperature compensated flowmeter easy and cost effective installation of the senor no pressure loss caused by the sensor no moving parts, i.e.
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationVZFA/VZOA MISURATORI DI PORTATA FUEL OIL METERS. CONTOIL VZFA/VZOA , versions for special requirements / applications
VZFA/VZOA FUEL OIL METERS MISURATORI DI PORTATA CONTOIL VZFA/VZOA 5...50, versions for special requirements / applications For applications requiring an increased accuracy of ± % or better, such as: Versions
More informationTOPAS PMW-basic. Customer benefits. Product features
TOPAS PMW-basic The TOPAS PMW-basic product line covers a wide range of applications in hot water measurement. This innovative system offers all types of water measurement right up to data integration
More informationAvailable in sizes DN 25, 30, 40 and 50 mm, Multimag TM is a class B multi-jet turbine meter for commercial and industrial applications.
Multimag TM Multi-jet Turbine Water Meter DN 25 to DN 50 mm haracteristics Velocity type meter Direct magnetic transmission lass ISO 4064 vailable in sizes DN 25, 30, 40 and 50 mm, Multimag TM is a class
More informationMidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin
MidFlow Model PT / Fuel Oil Flowmeters135 Sliding Vane Meters DN 25-50 (1-2 ) _ 135 Product Bulletin WWW.VAF.NL 1 Introduction VAF Instruments MidFlow Model PT positive displacement sliding vane type liquid
More informationDomestic water meters
EnergyMetering Domestic water meters Multi-jet wet dial meters Multi-jet dry dial meters Multi-jet semi-dry dial meters/roller Protect Cartridge meters All that counts. Cold water meters Hot water meters
More informationOscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids
Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance
More informationCONTOIL Fuel oil meters
CONTOIL Fuel oil meters Applications Flow measurement of mineral oils such as heating or propellant fuels In burners, on board ships, land vehicles and fixed installations Marine and metrological type
More informationELSTER KENT Non-Metalic Products. Meters, Meterboxes & Accessories made from Engineering Plastics
ELSTER KENT Non-Metalic Products Meters, es & Accessories made from Engineering Plastics 1 Accuracy and long-life stem from engineering excellence Locking Device Reading Slot Elster Kent range of non-metallic
More informationINSERTION flow sensor for continuous flow measurement
INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)
More informationRMG Meßtechnik GmbH. Publication No E
Turbine meter TRZ 03 RMG Meßtechnik GmbH Publication No. 3.161-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de
More informationWATER METERS.
WTER METERS Hydrodynamic design High protection Multi-jet technology ensures uniform distribution of load on the turbine located thanks to the water inlet diffuser. The movement activates the magnetic
More informationSeries 240 and 250 Valves with perforated plug
Series 240 and 250 Valves with perforated plug DIN and ANSI versions Application Optimized trim for critical conditions in applications DN 25 to 500 NPS 1 to 20 Nominal pressure PN 16 to 400 Class 150
More informationMetal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam
Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,
More informationCONTOIL Fuel oil meters
CONTOIL Fuel oil meters Applications Flow measurement of mineral oils for heaters and fixed installations. VD 4-410 e 07.2012 Features Classical version with mechanical display State-of-the-art design
More informationPressure transmitter COMPACT ECOnomic
Pressure transmitter COMPACT ECOnomic for food/pharmaceutical/biotechnology, Type series CA1110 Features Digitale pressure transmitter Hygienic design according to EHEDG Case and wetted parts of stainless
More informationMX-SERIES OVAL GEAR FLOW METERS
Data Sheet MX-SERIES OVAL GEAR FLOW METERS Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com MX-Series Oval Gear Flow Meters Features and Advantages P From ¼ DN8 at 0.5LPH to 4 DN100
More informationDesign and application
Design and application The function of the SGM is based on the variable area float principle. In all cases where a dependable device is required for indicating instantaneous values and monitoring the flow
More informationInline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )
EE771/EE772 Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the
More informationPF6 Stainless Steel Piston Actuated On/Off Valves
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationKM-165, KM-185, KM-200 OVERVIEW. Flow Monitor & Flow Indicator. Features. Operation
Flow Monitor & Flow Indicator KM-165, KM-185, KM-200 OVERVIEW Operation Float measuring principle Application Cooling systems and cooling circuits Mechanical engineering Pharmaceutical industry Chemical
More informationFlowmeter DFM
Flowmeter DFM 165 50 Nominal size DN 10-65 Nominal size /8 2 1/2 Nominal pressure PN 10 bar Features Measuring range to 50,000 l/h suitable for a wide range of applications for gaseous medium types, water,
More informationCheck Valves DN PN 80, 100, 160
47 DN 300-1000 PN 80, 100, 160 Designed to automatically prevent back flow of working medium, when transmitting non-aggressive natural gas and other non-aggressive media at the temperature ranged -60 C
More informationVisual Level Indicators (VLI) Plastic & Top of Tank Series Series Type Material Pipe Operating Operating Page
Visual Level Indicators (VLI) Plastic & Top of Tank Series Series Type Pipe Operating Operating Page O.D. x s Pressure Temperature Plastic thread 10 25670 PVDF 63.0 x 3.6 2.5-10 thread max. 140 C 61 Plastic
More informationFlowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.
Flowmeters with Float Series 6001/ 6002 Flow Measurement of Gases & Clear Liquids with Float Series 6001 & 6002. Measurement Principle Variable area obtained by the displacement of a float in a conical,
More informationXMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.
Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others
More informationWater Metering THE WORLD S MOST ACCURATE COMMERCIAL HYBRID METER
Water Metering THE WORLD S MOST ACCURATE COMMERCIAL HYBRID METER H5000: The World s Most Accurate Commercial Hybrid Meter The H5000 s true hybrid design has the widest measuring range of any water metering
More informationMagnetic Inductive Flowmeter EP / UMF2 (B)
Magnetic Inductive Flowmeter EP / UMF2 (B) High accuracy 0.3 % of reading No maintenance required no pressure drop different lining materials different electrode materials inexpensive earthing electrode
More informationTurbine flowmeters Series TM
Turbine flowmeters Series TM Suitable for liquids Possibility of installation in all flow directions Special design for high pressure available Excellent relationship flow range / flowmeter size Low pressure
More informationtprime TM Series 280T
MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.
More information/ 855 / 857 / 861 / / 870 / 875 / 880 / 885. Variable Area Flowmeter, Plastic
Variable Area Flowmeter, Plastic Construction The flowmeter operates according to the variable area principle. Metering tubes are available in PA transparent or Polysulphone suitable for inert or corrosive*
More informationThe EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.
Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power
More informationFlow. Oval Wheel Flowmeter Model DOE
Oval Wheel FIowmeter for low and high viscous liquids measuring monitoring analysing DOE Measuring range: 0.5 36 l/h und 1 40 l/min Viscosity range: 1 1000 cp Accuracy: ±1% of reading Material: stainless
More informationThe Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been
The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been established over the last 80 years. The electromagnetic
More informationMWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.
Industrial Temperature Assemblies measuring monitoring analysing MWD OO Meassuring range -200...+600ºC. OO Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic. OO Output: Resistance or analogue
More informationPF6 Stainless Steel Piston Actuated On/ Off Valves
Page of TI-P7- CH Issue Cert. No. LRQ 9 ISO 9 PF Stainless Steel Piston Actuated On/ Off Valves Description A -port pneumatically actuated on / off stainless steel valve for use on steam, water, air, oil
More informationExamples 3/2-way valve A T NO: Symbol
1/1 Hauhinco-3_2-way valve_b1_dn3-25_pn320_pn500_x,y-intern water s 01/2016 3/2-way valve B1 X,Y - DN3 DN25 PN320, PN500 Features: Hydraulically actuated directional seat valve controlling liquid media.
More information600, 630. Diaphragm Valve, Plastic
Diaphragm Valve, Plastic Construction The /630 pneumatically operated 2/2-way valves have a low maintenance piston actuator which can be controlled by inert gaseous media. They have an integral optical
More informationSeries V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator DIN version Application Control valves for heat transfer applications using organic media according to
More informationContinuous level measuring system NB 4000 Selection list
Table of contents Page Overview P2 Specification / application P3 P4 Options / Accessories P6 Dimensions / materials P7 Spare parts P9 Electrical installation P11 Subject to change. All dimensions in mm
More informationVORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter
R VORTEX FLOW METTER DVH Measuring range: 3-8... 3 057-280 187 m3n/h Accuray: ± 0,7 % of reading (liquids) ± 1 % of reading (gases and steam) P m a x : 100 bar abs; tm ax : 400 C Connection: ANSI ½ up
More informationULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2
AB AXIS INDUSTRIES ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2 TECHNICAL DESCRIPTION, INSTALLATION AND USER INSTRUCTIONS PESF2V01 KAUNAS Contents Page SAFETY INFORMATION... 1. APPLICATION FIELD... 2. TECHNICAL
More informationFor industrial applications For marine applications With proximity switch. Piston type flow switches
JJ For industrial applications JJ For marine applications JJ With proximity switch Piston type flow switches DB_Piston_type_flow_switches 01/2016 199 Piston type flow switches Piston type flow switches
More informationULTRASONIC HEAT METER
MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.
More informationFlap-Type Flow Meter Prall
Suitable for H 2 O, acids, alkaline solutions and gases Spring-loaded flap Horizontal or vertical direction of flow Largely independent of viscosity Limit contacts, optional Analog output 4 20 ma, optional
More informationRHM The world s largest Coriolis Mass Flowmeter for flow rates up to kg/min
RHM 160 - The world s largest Coriolis Mass Flowmeter for flow rates up to 25000 kg/min The RHM 160 can measure flow rates up to 1500 t/hr with the patented Omega shape meter technology manufactured by
More informationElectronic Water Meters in measuring cell design
5 343 SIEMECA Electronic Water Meters in measuring cell design WMC... WMH... Electronic, mains-independent meters to acquire water consumption in autonomous domestic water plants. Storage and display of
More informationSTEEMCO-MAS Flowmeter for Steam
STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationRHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version
RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version The RHM 80 can measure flow rates up to 480 t/hr with the patented Omega shape meter technology manufactured by
More informationMetering systems 0483EN October 2013 Metering units for sanitary or service water
08EN October 0 Losses of Pressure The diagram showing losses of pressure is displayed below. For lower flow rate values, dashed lines are valid, due to the effect of the check valve spring.,00 Kv =, Δp
More informationTechnical Data B20x. 8 BiRotor, APL. Model B201 [8 ] Model B203 [8 ] Model B204 [8 ] Model B205 [8 ]
Technical Data BiRotor, APL Model B201 [] Model B203 [] Model B204 [] Model B205 [] General The BiRotor Meter is a positive displacement meter utilized in the most demanding applications requiring accuracy,
More informationSeries V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator DIN version Application Mixing or diverting valves for heat transfer applications using organic media
More informationBFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4
Flow Switches Index: B / 923-1838 BFS-10-N / BFS-10-O for monitoring liquids, with or without optical display Features set point continuously adjustable rugged, low hysteresis, any mounting position, high
More informationTemperature sensors. and accessories for heat and cooling measurement points. Applications. Benefits. Features
Temperature sensors and accessories for heat and cooling measurement points Applications Temperature sensors are metrological components for heat or cold measuring points. They are used in pairs and measure
More informationGas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74
Temperature Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74 WIKA data sheet TV 27.02 Applications Food industry Sanitary applications Bio and pharmaceutical
More informationCONTOIL Fuel oil meters
CONTOIL Fuel oil meters Applications Flow measurement of mineral oils for heaters and fixed installations. VD 4-410 e 11.2012 Features Classical version with mechanical display State-of-the-art design
More informationTechnical Data. BiRotor Plus Positive Displacement Meter
Technical Data BiRotor Plus Positive Displacement Meter B27X 3 ANSI (DN80) B30X 6 ANSI (DN150) B28X 4 ANSI (DN100) B31X 8 ANSI (DN200) B29X 6 ANSI (DN150) B32X 10 ANSI (DN250) General The BiRotor Plus
More informationEW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS
EW10 Series Multijet Water Meters DN15 0 FOR COLD AND WARM POTABLE WATER APPLICATIONS CONTENTS PRODUCT DATA Fig. 1. EW100BM / EW101BM Contents... 1 General... 2 Application... 2 Features... 2 Design...
More informationInline Paddle Wheel Flow Switch
Inline addle Wheel Flow Switch Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type can be combined with... Valve Alarm
More informationR677. Diaphragm Valve, Plastic
Diaphragm Valve, Plastic Construction All medium wetted parts, the bonnet and handwheel of the GEMÜ 2/2-way diaphragm valve are made of plastic. The low maintenance plastic bonnet has an ergonomically
More informationDifferential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar
Pressure Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar WIKA data sheet PV 27.13 for further approvals
More informationSuperstatic 440. Static Heat Meter, Static Cooling Meter. Application
Superstatic 440 Static Heat Meter, Static Cooling Meter Application Design The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,
More informationRHM Coriolis Mass Flowmeter for high Flow Applications
RHM 100 - Coriolis Mass Flowmeter for high Flow Applications The RHM 100 can measure up to 720 t/hr with the superior and patended Omega shape meter technology manufactured by rheonik, the mass flowmeter
More informationSupplementary instructions Flanges according to DIN - EN - ASME - JIS - GOST Technical data. Document ID: 31088
Supplementary instructions Flanges according to DIN - EN - ASME - JIS - GOST Technical data Document ID: 10 1 Product description 1 Product description 1.1 Specifications The described flanges are threaded
More information