WATER METERS.

Size: px
Start display at page:

Download "WATER METERS."

Transcription

1 WATER METERS

2 Design Hydrodynamic Mechanism Independent The operation of the Hydrotangential meter is based on a turbine at the top of the meter, which allows the solid particles go through without obstructing the meter. There are no obstacles in the measuring tube, therefore pressure loss are very low. With a completely independent mechanism and protected against magnetic fields, the Hydrotangential counter allows a simpler repair, without having to extract water meter from the installation, greater durability and security against fraud. Al rights reserved. Copyright. 206 HIDROCONTA. S.A.

3 High flow rate The system on which the Hidrotangencial counter is based is designed to provide a high flow rate with the minimum pressure loss. Water Engineering Its operation is based on a turbine or propeller located at the top of the measuring tube. The rotation of the propeller is transmitted by magnetic transmission through a shaft and gear to a head that accumulates in its totalizer the volume of water circulated through the water meter. Al rights reserved. Copyright. 206 HIDROCONTA. S.A.

4 Dial 6 lining figures dial Rotary starwheel for leak detection HIDROCONTA m³ Qn.25m³/h Pm.6 bar Clase A x 0, x0,0 Class A. ISO Note: the equip does not have conformity certificate for its use as a mandatory metrological instrument on the national level. Technical specifications - Tangential propeller and removable mechanism. - Class A horizontal installation (observe the flow direction indicated on the body by an arrow). - Low pressure loss. - Dry sphere. - Magnetic transmission. - Direct reading on the dial. - Protective cover. - Cast iron body. Al rights reserved. Copyright. 206 HIDROCONTA. S.A.

5 Disassembly Description Material Description Material Screw for stealing Stainless Steel Bush for adjustment Screw Stainless Steel Upper plate Cover Assembly Screw Register Assembly Central gear Component Fixing pin Cover plate MPPO Retainer Ring ABS O-ring Rubber Screw Transmission gear Assembly Pin Stainless Steel Adjusting Lever Support ABS Turbine Component Bolt for Sealing Stainless Steel Adjusting plate Bolt M2x35 Stainless Steel Bush Nylon Gasket Stainless Steel Measuring Chamber MPPO Adjusting Nut Fixing Screw Flange Plate Ductile Iron O-ring Rubber O-ring Silicon Rubber Body Cast Iron O-ring Silicon Rubber Al rights reserved. Copyright. 206 HIDROCONTA. S.A.

6 Dimensions L H D mm Inch 2" 2-/2" 3" 4" 5" 6" 8" 0" 2" Kg 9,70,82 3,06 5,44 8,63 25,6 37,65 6,40 77,95 D mm Weight H Calibre L Coupling - Flange PN6 Packing UNITS DIAMETER PER BOX Length Width High KG DN 50 27,5 9 2,4 9,99 DN ,7 2,8 2,5 DN 80 30,4 22,2 24,2 3,40 DN 00 32,2 24,5 27,5 5,90 DN 25 32, ,5 DN 50 34,7 28, ,80 DN 4 37,3 43,8 DN ,7 68,8 DN ,9 5 56,8 90,20 Working conditions Room temperature GROSS WEIGHT BOX DIMENSIONS (CM) Maximum pressure 0. C ~ 40 C 6 bar 43,85 Maximum permissible error Range Error ( %) Q.min Q < Q.t ± 5% Q.t Q Qmax ± 2% Al rights reserved. Copyright. 206 HIDROCONTA. S.A.

7 Technical specifications Calibre mm Pulg. 2" 2-/2" 3" 4" 5" 6" 8" 0" 2" Q. Q. Q. de Q. Minimum maximum nominal transitional minimun Reading m3/h 30 5 m3 4,5,2 0,0002 0,0002 0,002 0,002 0,002 0,002 0,002 0,02 0, , , ,2 4, Maximum Reading Classe A ISO 4064 Pressure loss curve 50mm Pressure loss (bar) mm 80mm 00mm 25mm 50mm mm mm 300mm Flow rate ( m3/h) Al rights reserved. Copyright. 206 HIDROCONTA. S.A.

8 Flow error curve Error (%) Qmin Qt Qn Qmax Flow rate ( m3/h) Pulse emisor Type Reed sensor Pulse value DN 50-25: pulse 00L DN : pulse 000L Min. amperage to close contact 0 ma Max. amperage to close contact 00 ma Closed contact impedance <Ω Open contact resistance ~ Max. supportable voltage 24V Max. Stabilization time 00us Closed contact lapsed time 20% of cycle Al rights reserved. Copyright. 206 HIDROCONTA. S.A.

9 Diagrams for installing Water disrupting elements upstream from the meter. DN= Ø water meter. Required length upstream from the meter = L With flow-correcting cartridge Without flow-correcting cartridge L=5DN L=5DN Centrifuge pump 3DN L=0DN Sluice valve fully open Sluice valve being adjusted L=0DN L=3DN L=5DN L=3DN L=0DN L=3DN L=5DN L=3DN L=0DN L=3DN Screen filter Elbows T-joint The precision of a Hidrotangencial can be aected by turbulence due to such elements as elbows, regulator valves, T-joints, etc.; consequently, in these cases a straight section is required before the meter. However, this straight section can be reduced or replaced by a flow-stabilising cartridge upstream from the meter and connected to it. Reduction cones Expansion cones Installation instructions - It is recommended to place the watermeter at a low point in the installation - Place the meter so that the arrow matches the direction of the water flow. - Do not force the meter during assembly; avoid tension or torsional stress, especially to the threaded connections. - The meters must always be full of water when operating and installed below the slope of the rest of the pipeline. This stops air pockets from forming inside. - If the water in the pipeline contains large suspended particles, an initial screening filter should be installed. - Fit a valve upstream from the meter to facilitate maintenance or repair. A new pipeline should be drained before fitting a meter to eliminate particles. - The meter connection can be instaled on horizontal, oblique or vertical pipe. - The inside diameter of the pipe must be equal to the nominal diameter of the watermeter. - If there is air in the pipeline, suckers must be fitted to avoid incorrect readings. Al rights reserved. Copyright. 206 HIDROCONTA. S.A.

10 DN (MM) PN OUTSIDE DIAMETER (MM) BOLTS CIRCLE DIAMETER ( MM) Nº BOLTS BOLTS DRILL DIAMETER ( MM) 50 PN0/ PN0/ PN0/ PN0/ PN0/ PN0/ PN PN PN PN UNE-EN 092- Flange dimensions * Para bridas ANSI consultar. Bolts drill Outside diameter Bolts circle Inside diameter Al rights reserved. Copyright. 206 HIDROCONTA. S.A.

11 FAQ - Has the turbine broken? The rupture of the turbine may be caused by the presence of solid particles of considerable size, for example, blocks and stones which may be suspended in the water. In this case you must replace the counter mechanism and place a filter before the counter so it does not happen again. 2- The water meter does not add up? It is likely that it is stuck, has some internal part damaged or has suffered wear and tear due to aging. When an aging wear occurs, the meter may add up to m3, but not the actual ones. In this case, the damaged element must be replaced. Our counters thanks to its hydrodynamic design with independent mechanism makes this type of repairs very simple. Tip: have complete mechanisms to replace the faulty meter while it is being repaired Al rights reserved. Copyright. 206 HIDROCONTA. S.A.

12 CUANDO EL AGUA ES LO QUE CUENTA Ctra. Sta Catalina, 60 Murcia (3002) España T: F: Hidroconta disclaims responsibility for errors in the information contained in this document, which may be modified without notice. Al rights reserved. Copyright. 206 HIDROCONTA. S.A.

WATER METERS.

WATER METERS. WTER METERS Hydrodynamic design High protection Multi-jet technology ensures uniform distribution of load on the turbine located thanks to the water inlet diffuser. The movement activates the magnetic

More information

Installation Instruction Bulk water meter REMOVABLE ELEMENT WOLTMAN COLD (HOT) WATER METER MODEL: LXLC-50~500

Installation Instruction Bulk water meter REMOVABLE ELEMENT WOLTMAN COLD (HOT) WATER METER MODEL: LXLC-50~500 REMOVABLE ELEMENT WOLTMAN COLD (HOT) WATER METER MODEL: LXLC-50~500 LXLC(R)-50-200 LXLC(R)-250-300 APPLICATION Measuring the volume of cold (hot) water passing through the pipeline FEATURES Magnet-drive,

More information

Quantometer MZ. Description

Quantometer MZ. Description Quantometer MZ < High accuracy budget meter < Flow rate up to 10000 m 3 /h < Pressure range up to 100 bar < Equipped as standard with the cyble target. < Various options available: Low and high frequency

More information

WESAN WP WOLTMAN METER

WESAN WP WOLTMAN METER WESAN WP WOLTMAN METER APPLICATION The bulk water meter WESAN WP can be used for measuring volumes of cold water (up to 50 C) in supply lines with high flow at low pressure loss. The measuring chamber

More information

T O PA S Applications Features Your benefits

T O PA S Applications Features Your benefits TOPAS Hot water Applications The TOPAS hot water meter is a velocity flowmeter based on the well-established multijet measuring principle. It operates over a wide measuring range and is used in all areas

More information

WESAN WP 222. Bulk Water Meter Woltman

WESAN WP 222. Bulk Water Meter Woltman APPLICATION The bulk water meter WESAN WP can be used for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. FEATURES 4 For horizontal and vertical installation

More information

Volumeter. RMG Meßtechnik GmbH. Publication No E

Volumeter. RMG Meßtechnik GmbH. Publication No E Volumeter TRZ 03-K RMG Meßtechnik GmbH Publication No. 3.171-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de

More information

ELSTER KENT Non-Metalic Products. Meters, Meterboxes & Accessories made from Engineering Plastics

ELSTER KENT Non-Metalic Products. Meters, Meterboxes & Accessories made from Engineering Plastics ELSTER KENT Non-Metalic Products Meters, es & Accessories made from Engineering Plastics 1 Accuracy and long-life stem from engineering excellence Locking Device Reading Slot Elster Kent range of non-metallic

More information

RMG Meßtechnik GmbH. Publication No E

RMG Meßtechnik GmbH. Publication No E Turbine meter TRZ 03 RMG Meßtechnik GmbH Publication No. 3.161-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de

More information

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve Self-operated Pressure Regulators Type 41-23 Universal Pressure Reducing Valve ANSI version Application Pressure regulators for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN

More information

Domestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features

Domestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features Domestic Water Meter Elin Wasserwerkstechnik Contact Water Meter MTM for cold water Features Nominal diameter DN15 to DN50 Cold water up to 30 C (safe up to 50 C) Operating pressure up to 16 bar Control

More information

Turbine gas flow quantometer series CPT

Turbine gas flow quantometer series CPT Turbine gas flow quantometer series CPT CPT quantometers, designed in order to provide a reliable and inexpensive measuring device [non fiscal], with features alike those of fiscal turbine meter, are maintenance

More information

Octave Water Meter Installation Manual

Octave Water Meter Installation Manual Octave Water Meter Installation Manual 1.0 Notes For proper flow measurements, the OCTAVE s measuring tube should be completely full at all times. Non-wetted sensors show loss of signal. Though this will

More information

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Self-operated Pressure Regulators Type Universal Excess Pressure Valve Self-operated Pressure Regulators Type 41-73 Universal Excess Pressure Valve ANSI version Application Pressure regulator for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN 15

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and Safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe

More information

Ref ALL POSITIONS CAST IRON CHECK VALVE PN16. Model/Ref:

Ref ALL POSITIONS CAST IRON CHECK VALVE PN16. Model/Ref: Model/Ref: 363-366 www.lauridsenindustri.com Size : Ends : Min Temperature : Max Temperature : DN 50 to 600 Flanges R.F. ISO PN10/16-10 C + 130 C Max Pressure : 16 Bars up to DN300 ( 10 bars over ) Specifications

More information

Fluxi 2000/TZ Turbine Gas Meter

Fluxi 2000/TZ Turbine Gas Meter Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The

More information

Available in sizes DN 25, 30, 40 and 50 mm, Multimag TM is a class B multi-jet turbine meter for commercial and industrial applications.

Available in sizes DN 25, 30, 40 and 50 mm, Multimag TM is a class B multi-jet turbine meter for commercial and industrial applications. Multimag TM Multi-jet Turbine Water Meter DN 25 to DN 50 mm haracteristics Velocity type meter Direct magnetic transmission lass ISO 4064 vailable in sizes DN 25, 30, 40 and 50 mm, Multimag TM is a class

More information

DAV - M DAV-M. Air Release and Vacuum Break Valves. Product Catalogue. (Metal Air Valves) DAV-M

DAV - M DAV-M. Air Release and Vacuum Break Valves. Product Catalogue. (Metal Air Valves) DAV-M DAV-M Air Release and Vacuum Break Valves Product Catalogue DAV - M DAV-M (Metal Air Valves) Edition / DAV Series DAV-M General DAV-Metal Air Release and Vacuum Break Valves First Operation: Venting air

More information

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 ANSI version Application Pressure regulators for set points from 0.075 to 400 psi (5 mbar to 28 bar) Valves in NPS ½ to 4

More information

Fluxi 2000/TZ Turbine Gas Meter

Fluxi 2000/TZ Turbine Gas Meter Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The

More information

VZO Pressure drop curves See Meter data. Option: Reed pulser or RV / IN pulser

VZO Pressure drop curves See Meter data. Option: Reed pulser or RV / IN pulser VZO 15...50 Technical data 1) Volume display on roller counter, in litres fuel oil meter with threaded or flanged ends for horizontal, vertical or inclined mounting Option: Reed pulser or RV / IN pulser

More information

Domestic water meters

Domestic water meters EnergyMetering Domestic water meters Multi-jet wet dial meters Multi-jet dry dial meters Multi-jet semi-dry dial meters/roller Protect Cartridge meters All that counts. Cold water meters Hot water meters

More information

M&H AWWA C508 STANDARD SWING CHECK VALVES

M&H AWWA C508 STANDARD SWING CHECK VALVES GENERAL M&H AWWA C508 STANDARD SWING CHECK VALVES Style 59-02 plain / 159-Lever & Weight / 259-02 Lever & Spring Sizes 2 Through 36 Water / Sewage Service M&H Swing Check valves are widely specified by

More information

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE TABLE OF CONTENTS General Information...4 Warranty...4 Included Items...4 Operation...5

More information

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Self-operated Pressure Regulators Type Universal Excess Pressure Valve Self-operated Pressure Regulators Type 41-73 Universal Excess Pressure Valve Application Pressure regulators for set points from 0.05 to 8 bar Valve nominal sizes DN 15 to 100 Nominal pressure PN 16 to

More information

Pneumatic Control Valve Assembly Type 3331/3278

Pneumatic Control Valve Assembly Type 3331/3278 Pneumatic Control Valve Assembly Type 3331/3278 Fig. 1 Type 3331/3278 Pneumatic Control Valve Assembly 1. Design and principle of operation The pneumatic control valve assembly consists of a Type 3331

More information

Delta Commercial & Industrial Rotary Meter

Delta Commercial & Industrial Rotary Meter Delta Commercial & Industrial Rotary Meter Itron's Delta range of rotary gas meters comprises innovative and high quality products. Characterized by compact dimensions and easy maintenance, the Delta

More information

Combi valves PN 16 with flanged connections

Combi valves PN 16 with flanged connections 4 315 ACVATIX Combi valves PN 16 with flanged connections Pressure Independent Combi Valves VPF43.. With integrated pressure differential controller Valve body made of gray cast iron GJL-250 DN 50, DN

More information

LBTC Series Positive Displacement Rotary Vane Flow Meters

LBTC Series Positive Displacement Rotary Vane Flow Meters LBTC Series Positive Displacement Rotary Vane Flow Meters Summary LBTC Series positive displacement rotary vane flow meters are independently designed and manufactured by our company on the base of absorbing

More information

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74. Data sheet Page: 1 / 5 Operating data Requested flow rate 160.00 m³/h Actual flow rate 159.85 m³/h Operating data determined for maximum inlet pressure Actual developed head 20.96 m Requested developed

More information

Type / Material code Body* Disc Stem Lining**

Type / Material code Body* Disc Stem Lining** Design butterfly valve is designed with lug or flange connection. Lug connection in dimensions DN 32-300, flange connecton DN 300-1000. is available in pressure ratings PN 10 /16 according to dimension.

More information

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas Volumeter TRZ 0-K PRODUCT INFORMATION Reliable Measurements of Gas Method of operation, Construction Method of operation The TRZ 0-K Volumeter is a flow meter suitable for metering gases, where the rate

More information

Materials : Cast iron or stainless steel body

Materials : Cast iron or stainless steel body Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 40 to 600 Between flanges PN10/16 or PN25-10 C + 90 C for NBR, 110 C for EPDM,180 C for FKM Max Pressure : 10 to 16 Bars ( according

More information

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator DIN version Application Control valves for heat transfer applications using organic media according to

More information

Manual valves. automatic meters and valves

Manual valves. automatic meters and valves Manual valves automatic meters and valves Butterfly valves manual valves Advanced technical design 1. Robust and lightweight leverage system. Ergonomic design. Protection of gear mechanism.. Flange fitting

More information

series BUTTERFLY VALVE DOUBLE ECCENTRIC FLANGED FAF 3800 PRODUCTION STANDARDS DN100 DN2000 PN Design EN 593 EN ISO Flanged

series BUTTERFLY VALVE DOUBLE ECCENTRIC FLANGED FAF 3800 PRODUCTION STANDARDS DN100 DN2000 PN Design EN 593 EN ISO Flanged PRODUCTION STANDARDS DN100 DN2000 PN 10-16-25 Design EN 593 Connection End Connection EN 1092-2 ISO 7005-2 - Flanged EN 558 Series 14 DIN 3202 F4 Marking EN 19 Tests EN 12266-1 Corrosion Protection Electrostatic

More information

Delta Commercial & Industrial Rotary Meter

Delta Commercial & Industrial Rotary Meter Delta ommercial & Industrial Rotary Meter Delta meters are volumetric meters. The fl ow of gas moves the pistons and each rotation traps and transfers a specifi c volume of gas. The movement is mechanically

More information

ProFlow TO BE REALLY SURE. Vane Meters. Experience in flow measurement. Introduction

ProFlow TO BE REALLY SURE. Vane Meters. Experience in flow measurement. Introduction ProFlow N142 P R O D U C T B U L L E T I N Vane Meters Special versions This brochure comprises only VAF Instruments standard delivery program. Special flowmeter variants can be offered as tailor-made

More information

Pressure Reducing Valve Type 2114/2415

Pressure Reducing Valve Type 2114/2415 Pressure Reducing Valve Type 2114/2415 Fig. 1 Type 2114/2415 1. Design and principle of operation The Type 2114/2415 Pressure Reducing Valve consists of the Type 2114 Valve and the Type 2415 Actuator.

More information

PETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l.

PETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l. Double Case PD Flowmeters Technical Bulletin The trusted specialist manufacturer of high precision instruments that relies upon the accurate measurement of fluid volumes Trust in us Our Quality Counts

More information

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No:

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No: Three-Piece ball valve EA-307 Series PED Category I, II EA-307 User Manual English Version [DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary.

More information

Turbine flowmeters Series TM

Turbine flowmeters Series TM Turbine flowmeters Series TM Suitable for liquids Possibility of installation in all flow directions Special design for high pressure available Excellent relationship flow range / flowmeter size Low pressure

More information

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam Nominal size

More information

M&H AWWA C508 STANDARD SWING CHECK VALVES

M&H AWWA C508 STANDARD SWING CHECK VALVES GENERAL M&H AWWA C508 STANDARD SWING CHECK VALVES Style 59-02 plain / 159-Lever & Weight / 259-02 Lever & Spring Sizes 2 Through 36 Water / Sewage Service M&H Swing Check valves are widely specified by

More information

50 Hz PX CHANNEL 1. Performance curves. data refered to : W ater, pure [100%] ; 20 C; 0,9983kg/ dm³; 1,001mm²/ s. Tolerances acc.

50 Hz PX CHANNEL 1. Performance curves. data refered to : W ater, pure [100%] ; 20 C; 0,9983kg/ dm³; 1,001mm²/ s. Tolerances acc. Performance curves 50 Hz [m] 11,6 data refered to : W ater, pure [100%] ; 20 C; 0,9983kg/ dm³; 1,001mm²/ s Head Tolerances acc. ISO 9906 Annex A 11,2 10,8 10,4 10 9,6 9,2 8,8 8,4 8 7,6 7,2 6,8 6,4 6 5,6

More information

FIVC. Static Balancing Valve. Technical data. Dimensions

FIVC. Static Balancing Valve. Technical data. Dimensions FIVC Static Balancing Valve Grey Cast Iron PN 16 Technical data Main features and materials High tightness (leakproofness class - A according to EN - 12266-1) Compact settlement Environment-friendly Tests

More information

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection) Series 42 Self-operated Regulators Type 42-10 RS Check Valve (backflow protection) Application Designed to protect nitrogen and compressed air networks against backflow from directly connected systems.

More information

DATA BOOKLET LSD SERIES. Suction Diffusers. Pumps Motors ISO 9001 Company. Catalogue Pumping Solution

DATA BOOKLET LSD SERIES. Suction Diffusers. Pumps Motors ISO 9001 Company. Catalogue Pumping Solution SERIES DATA BOOKLET Suction Diffusers Pumps Motors ISO 9001 Company Catalogue 2011 Pumping Solution CONTENTS INTRODUCTION Page 3 FEATURES AND BENEFITS Page 3 DESIGN FEATURES Page 4 MATERIAL OF CONSTRUCTION

More information

CONTOIL VZFA/VZOA , versions for higher requirements / applications

CONTOIL VZFA/VZOA , versions for higher requirements / applications CONTOIL VZF/VZO 4...50, versions for higher requirements / applications For applications requiring an increased accuracy of ±0.5 % or better, such as: Measurement of L heating fuel or diesel in testing

More information

BERMAD Irrigation. Hydraulic Control Valves 900 series - Hydrometers. Water Control Solutions

BERMAD Irrigation. Hydraulic Control Valves 900 series - Hydrometers. Water Control Solutions Hydraulic Control Valves 900 series - Hydrometers Water Control Solutions Company Profile Experience and proven results have made BERMAD synonymous with water, and other fluid, control and management.

More information

VZFA/VZOA MISURATORI DI PORTATA FUEL OIL METERS. CONTOIL VZFA/VZOA , versions for special requirements / applications

VZFA/VZOA MISURATORI DI PORTATA FUEL OIL METERS. CONTOIL VZFA/VZOA , versions for special requirements / applications VZFA/VZOA FUEL OIL METERS MISURATORI DI PORTATA CONTOIL VZFA/VZOA 5...50, versions for special requirements / applications For applications requiring an increased accuracy of ± % or better, such as: Versions

More information

Performance curves. Performance dare To compare

Performance curves. Performance dare To compare Performance curves Performance dare To compare table of contents Pump Size RPM PAGE # 1 1/2 x 1-6AA 1800 1 3600 1 3 x 1 1/2-6AB 1800 1 3600 1 3 x 2-6AC 1800 1 3600 1 LF 1 1/2 x 1-8AA 1800 2 3600 2 1 1/2

More information

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids Flow rate measurement is independent of density, temperature, viscosity and pressure Pulsed coil excitation to

More information

Static Balancing Valve

Static Balancing Valve Static Balancing Valve Series W-JP45X-16Q Sizes: DN50-DN300 APPLICATION The Series W-JP45X Static Balancing Valve is designed for flow balancing in cooling, heating or process water systems. Its measuring

More information

Metering systems 0483EN October 2013 Metering units for sanitary or service water

Metering systems 0483EN October 2013 Metering units for sanitary or service water 08EN October 0 Losses of Pressure The diagram showing losses of pressure is displayed below. For lower flow rate values, dashed lines are valid, due to the effect of the check valve spring.,00 Kv =, Δp

More information

PRESSURE RELIEF VALVE CONTROL VALVE

PRESSURE RELIEF VALVE CONTROL VALVE PRESSURE RELIEF VALVE CONTROL VALVE LEHRY Pressure Relief Valve, Sustaining or Backpressure Control Valve is designed to permitting flow when upstream pressure is above the adjustable setpoint of the control

More information

STEAM EXTRACTION / COLD REHEAD ACTUATED CHECK VALVES

STEAM EXTRACTION / COLD REHEAD ACTUATED CHECK VALVES STEAM EXTRACTION / COLD REHEAD ACTUATED CHECK VALVES More than 20 years of experience in design and manufacturing and service of custom made actuated Steamextraction Check valves for the Power Generation

More information

Size : Ends : Min Temperature : Max Temperature : Materials : PVC-U body

Size : Ends : Min Temperature : Max Temperature : Materials : PVC-U body Size : Ends : Min Temperature : Max Temperature : DN 65 to 200 mm Between flanges PN10/16 0 C + 40 C Max Pressure : 10 Bars up to DN125 Specifications : 7 positions lever Wafer type ISO 5211 mounting pad

More information

2 PIECES BALL VALVE PN63

2 PIECES BALL VALVE PN63 2 PIECES BALL VALVE PN63 Model/Ref: 220 www.lauridsenindustri.com Size : Ends : Min Temperature : Max Temperature : DN 15 to DN 400 Flanges ISO PN10/16-10 C + 120 C Max Pressure : 16 Bars up to DN 200

More information

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN Globe Valve Type 3241 Fig. 1 Type 3241 Globe Valve Mounting and Operating Instructions EB 8015-1 EN Edition July 2012 Contents Contents Page 1 Design and principle of operation.................... 4 2

More information

Nominal sizes: DN 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150 Pressure rating: PN 16. Product No. Nominal size Body connection

Nominal sizes: DN 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150 Pressure rating: PN 16. Product No. Nominal size Body connection Operating Instructions ERHARD Flow Indicator 1 Description of Product and Range of Application 2 Design Features Technical Data 3 Performance and Mode of Operation 4 Installation into the Pipeline Mounting

More information

MidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin

MidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin MidFlow Model PT / Fuel Oil Flowmeters135 Sliding Vane Meters DN 25-50 (1-2 ) _ 135 Product Bulletin WWW.VAF.NL 1 Introduction VAF Instruments MidFlow Model PT positive displacement sliding vane type liquid

More information

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump XFLO P U M P S XS SERIES Single Stage Double Suction Split Casing Centrifugal Pump General and Construction 1. Applications Waterworks, Irrigation, Drainage pumping stations, Power stations, Industrial

More information

BAYLAN AUTOMATED TEST BENCH

BAYLAN AUTOMATED TEST BENCH BAYLAN AUTOMATED TEST BENCH At this test bench, the electromagnetic flow meters are used with the measurement method. Calibrations of flowmeters are made with the help of the water collection tank and

More information

We proudly deliver a unique and

We proudly deliver a unique and Linear 3-Way Control Valve PN 10/16/25, DN15 - DN300 BENEFITS Nominal pressure PN 16 Almost linear Two balance single seats kvs Regulating capability > 25 kvr Leakage 0.05% of kvs For regulating of process

More information

M SERIES Multi-Jet Cold Water Meter

M SERIES Multi-Jet Cold Water Meter M SERIES Multi-Jet Cold Water Meter /4 1 1-1/2" 2" Maximum Flow GPM 0 0 1 Minimum Flow GPM.2.7 1. 2.0 Maximum Operating Pressure 0 psi Maximum Operating Temperature F ( C) Also Available in Hot Water Applications

More information

ANSI version. The valve closes when the differential pressure rises

ANSI version. The valve closes when the differential pressure rises Self-operated Regulators Series 42 Differential Pressure Regulator with Type 2424/Type 2428 Actuator and Type 2422 Valve Type 42-24 A Type 42-24 B Type 42-28 A Type 42-28 B ANSI version Application For

More information

Pressure relief controller V22 D28

Pressure relief controller V22 D28 Pressure relief controller V22 D28 For heavy oil and high-viscosity media Instructions for Mounting, Start-up and Maintenance SIBC VI.CB.I1.02 Contents 1. General data Page 1.1 Correct application 1 1.2

More information

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator DIN version Application Mixing or diverting valves for heat transfer applications using organic media

More information

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive Series CNI-M Usage For pumping toxic, volatile, explosive or other fluids harmful to the environment which call for service of hermetically

More information

TOPAS PMW-basic. Customer benefits. Product features

TOPAS PMW-basic. Customer benefits. Product features TOPAS PMW-basic The TOPAS PMW-basic product line covers a wide range of applications in hot water measurement. This innovative system offers all types of water measurement right up to data integration

More information

BUTTERFLY VALVE WAFER TYPE of carbon steel 311 ( ) series

BUTTERFLY VALVE WAFER TYPE of carbon steel 311 ( ) series Operation WAFER TYPE of carbon steel 311 (310-312) series C ont R o L Description Edition 23-07-2015 Wafer type butterfly valve 311 (310 312) series is used in industrial pipelines for demanding on-off

More information

1/2-2 INSTALLATION INSTRUCTIONS

1/2-2 INSTALLATION INSTRUCTIONS 1/2-2 INSTALLATION INSTRUCTIONS ZE Table of contents General Meter Configuration 1 Application, planning and installation 1 Safety precautions 1 Plant design Layout of piping 2 -Meter installation 2 -Correct

More information

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C Series CMIT in inline design Series CMAT with axial inlet ATEX 0 a Series CMAT Series

More information

Electromagnetic flowmeters

Electromagnetic flowmeters 02/97 Electromagnetic flowmeters Primary heads Installation instructions ECOFLUX IFS 1000 F Compact flowmeters IFM 1010 K IFM 1080 K CONTENTS Installation in the pipeline Pages 4-5 and 7-8 Grounding Pages

More information

Materials : Cast iron body EN GJL-250

Materials : Cast iron body EN GJL-250 Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 15 to DN 600 Flanges R.F. PN10/16-10 C + 120 C Max Pressure : 16 Bars up to DN 200 ( 10 bars over ) Specifications : Removable stainless

More information

INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL MANUAL

INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL MANUAL ISO 9001:2008 Via Renata Bianchi, 12 16152 Genova ITALY Tel. +39.01.6017016 Fax. +39-010-601-6021 www.tecnidro.com s INDEX 1. Introduction 1.1 Premise 1.2 Generality 1.3 Principle of operation 2. INSTALLATION

More information

Ref PTFE WAFER BUTTERFLY VALVE. Model/Ref:

Ref PTFE WAFER BUTTERFLY VALVE.  Model/Ref: Model/Ref: 1155 www.lauridsenindustri.com Size : Ends : Min Temperature : Max Temperature : DN 32/40 to 300 mm Between flanges PN10/16 and ISO PN20 ANSI150-25 C + 200 C Max Pressure : 16 Bars up to DN150

More information

PUMP TYPE SERIES SLM AVP ACCORDING TO API 685

PUMP TYPE SERIES SLM AVP ACCORDING TO API 685 Production range pumps: Pumps with magnet drive E Chemical centrifugal pumps according to DIN EN E Centrifugal pumps according to ANSI B. E Centrifugal pumps for refinery and petrochemical applications

More information

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC ... 3... 4 3000 rpm 50 Hz / 3600 rpm 60 Hz... 4... 5... 7 Modular pump / motor systems... 7 Materials...........................................................

More information

butterfly valves high performance TRIPLE OFFSET HP-TRI REV0

butterfly valves high performance TRIPLE OFFSET HP-TRI REV0 high performance EXECUTION 1st OFFSET 2nd OFFSET 3rd OFFSET The BELVEN-TRI series incorporate triple offset disc configuration. With this configuration the disc seal makes contact with body seat, only

More information

Spiratec ST14, ST16 and ST17 Sensor Chambers and Sensors

Spiratec ST14, ST16 and ST17 Sensor Chambers and Sensors Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

BUTTERFLY VALVE WAFER TYPE stainless steel 411 (41000) series PN40 For steam (fire safe versions) and 41001

BUTTERFLY VALVE WAFER TYPE stainless steel 411 (41000) series PN40 For steam (fire safe versions) and 41001 Operation WAFER TYPE stainless steel 411 (41000) series PN40 For steam (fire safe versions) 41101 and 41001 C ont R o L Description Edition Wafer type butterfly valve 411 (410) series are used in industrial

More information

Data sheet. Page: 1 / 7. ETL GG AV11D BKSBIE3M Inline pump. Operating data. Design

Data sheet. Page: 1 / 7. ETL GG AV11D BKSBIE3M Inline pump. Operating data. Design Data sheet Page: 1 / 7 Operating data Requested flow rate Requested developed head Pumped medium Ambient air temperature 20.0 C Fluid temperature 20.0 C Fluid density 998 kg/m³ Water Clean water Not containing

More information

FLUXI 2000/TZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift

FLUXI 2000/TZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift FLUXI 2000/TZ 652-099-2025 Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift ANNEX 6: CE Certificate of Conformity declares that the product:

More information

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Type 3535 Three-way Valve with bellows seal and rod-type yoke (partial view) Mounting and Operating Instructions EB 8135/8136 EN Edition

More information

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321 Valve Series V2001 Globe Valve Type 3321 Fig. 1 Type 3321 Valve with mounted rod-type yoke for pneumatic or electric actuators (partial view) Mounting and Operating Instructions EB 8111/8112 EN Edition

More information

Deluge Valves. Model 68 DE\ HM-MR. Hydraulically Actuated Manual-Reset Deluge Valve. Dorot Fire Protection Division

Deluge Valves. Model 68 DE\ HM-MR. Hydraulically Actuated Manual-Reset Deluge Valve. Dorot Fire Protection Division Dorot Fire Protection Division s Model 68 DE\ HM-MR Hydraulically Actuated Manual-Reset Certification & compliance by design ANSI FCI 70-2 Class VI seat leakage class UL listed under VLFT category Fire

More information

griswold 811 performance curves

griswold 811 performance curves griswold 811 performance curves pump size rpm page # 1 1/2 x 1-6AA 1800 1 3600 1 3 x 1 1/2-6AB 1800 1 3600 1 3 x 2-6AC 1800 1 3600 1 LF 1 1/2 x 1-8AA 1800 2 3600 2 1 1/2 X 1-8AA 1800 2 3600 2 3 X 1 1/2-8AB

More information

Type 431, 433. Balanced bellows design. Type Cap H2. 18 Adjusting screw with bushing. 19 Lock nut. 16 Upper spring plate. 12 Spindle.

Type 431, 433. Balanced bellows design. Type Cap H2. 18 Adjusting screw with bushing. 19 Lock nut. 16 Upper spring plate. 12 Spindle. Balanced bellows design 40 Cap H2 18 Adjusting screw with bushing 19 Lock nut 16 Upper spring plate 12 Spindle 9 Bonnet 54 Spring 14 Split ring 17 Lower spring plate 55 Stud 56 Nut 8 Guide with bushing

More information

½" to 4" (DN15 to DN100) LEA31 and LEA33 ANSI Control Valves Installation and Maintenance Instructions

½ to 4 (DN15 to DN100) LEA31 and LEA33 ANSI Control Valves Installation and Maintenance Instructions 00050/1 IM-P0-02 CH Issue 1 ½" to " (DN15 to DN100) LEA1 and LEA ANSI Control Valves Installation and Maintenance Instructions 1. Safety 2. Technical details. Installation and commissioning. Maintenance

More information

OPERATING INSTRUCTIONS Flow sensors with connecting flanges DN CE

OPERATING INSTRUCTIONS Flow sensors with connecting flanges DN CE OPERATING INSTRUCTIONS Flow sensors with connecting flanges DN 40 300 - CE Thank you for choosing our product, for your comfort we present you the operating instructions of flow sensors with connecting

More information

Flow controller (PN 25) AVQ - return and flow mounting

Flow controller (PN 25) AVQ - return and flow mounting Data sheet Flow controller (PN 5) - return and flow mounting Description is a self-acting flow controller primarily for use in district heating systems. The controller closes when set max. flow is exceeded.

More information

VZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side

VZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side VZ-01 Oil Counter for Light to Heavy Fuel Oil Description: Features / Mounting on pressure or suction side The VZ-01 series of volume counters are rotary piston meters that function without auxiliary electrical

More information

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit MAHLE Industrialfiltration is now Filtration Group. For more information, visit www.filtrationgroup.com Filter module AF 43 Nominal pressure 16 bar, nominal temperature 180 C; nominal width DN 80 to DN

More information

Butterfly valves. Introduction. Made of ductile cast iron

Butterfly valves. Introduction. Made of ductile cast iron Made of ductile cast iron Introduction The portfolio of valves supplied by Keulahütte GmbH in Krauschwitz is rounded off by butterfly valves and check valves, which have been designed according to international

More information

ULTRASONIC FLOW SENSOR IFX-M4-01

ULTRASONIC FLOW SENSOR IFX-M4-01 ULTRASONIC FLOW SENSOR IFX-M4-01 TECHNICAL DESCRIPTION, OPERATING INSTRUCTION IFX-M4-01 2012-09-10 TABLE OF CONTENTS 1. APPLICATION... 3 2. TECHNICAL DATA... 4 3. PACKAGE CONTENT... 6 4. OPERATING PRINCIPLE...

More information

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors. revision 04 2015 Woltmann type combined energy meter Woltmann flow meters for large nominal flows combined with calculator and temperature sensors. The WSTH and WPTH meters are designed for flow measurements

More information

Materials : Cast iron body EN GJL-250

Materials : Cast iron body EN GJL-250 Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 40 to 200 PN16 flanges R.F. - 10 C + 80 C with EPDM seat, 120 C with Metal seat Max Pressure : 16 Bars Specifications : Swing check

More information