Domestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features
|
|
- Belinda Adams
- 5 years ago
- Views:
Transcription
1 Domestic Water Meter Elin Wasserwerkstechnik Contact Water Meter MTM for cold water Features Nominal diameter DN15 to DN50 Cold water up to 30 C (safe up to 50 C) Operating pressure up to 16 bar Control pressure 25 bar Horizontal installation Dry dial multi-jet wheel cold water meter Metrological class B Very good initial sensibility Excellent measuring results and long stability With protection against magnetic manipulation At the dry dial type optimal working security is ensured also for polluted and corrosive potable water By order delivery with pulser for required output Possibility for additional pulser use for fixed output The high capacity magnetic clutch gives permanent and slipless momentum Insered filter Possibility for internal flow restrictor utilization The smallest reading value of the counter device is 0.05 litre Hermetically sealed counter device Plastic based coating of high strength ensures corrosion protection
2 Domestic Water Meter Elin Wasserwerkstechnik Contact Water Meter MTM for cold water Type MTM Nominal diameter DN mm Nominal volumetric flowrate Q n m 3 /h Maximal volumetric flowrate Q max m 3 /h Flowrate at P=1bar m 3 /h Transitional volumetric flowrate Q t l/h ,000 Minimal volumetric flowrate Q min l/h Initial sensibility l/h <10 <10 <25 <25 <25 <45 <45 Metrological class B Displayed min. quantity l 0.05 Displayed max. quantity m Built-in length L mm Connecting thread R zoll G 3/4 G 1 G 1 1/4 G 1 1/2 G 1 1/2 G 1 1/4 G 1 1/4 G 2 G 2 1/2 Sizes H mm h mm g mm Width B mm Weight kg Pulser Impulse values liter/pulse 1 or 10 or 100 or 1,000 Switching component Reed switch, plug type Switch protection Switching voltage U max = 100 V AC/DC Reed Switching current I max = 0,5 A Switching power P max = 0.2 W Pulse duration Switching power P max = 0.2 W at meter stop continous pulse possible Protection IP 65 Minor technical changes may occur in the course of further development. Overall dimensions: B B ELIN Wasserwerkstechnik Ges.m.b.H. Hainburgerstraße 33, A-1030 Wien Tel.: +43(0)1/ Fax: +43(0)1/ export@ewt.at
3 Domestic Water Meter Elin Wasserwerkstechnik Contact Water Meter MTM for cold water Dial: 3 MTM Q n1,5 m /h Klasse B Material: Meter body: Counter device: Cover lens: Wheel box: Other applied material: Brass Plastic Plastic, steel Brass or plastic Stainless steel Head loss graph MTM Typical error graph MTM Loss of head bar DN 15 DN DN 25 and DN 30 DN 40 DN 50 Error in measurement +5% +2% 0-2% -5% Flow m /h Flow m /h Qmin Q t Q n Q max Measuring error curve: Error limits: In the upper measuring range between Qmax and Qt ± 2 % In the lower measuring range between Qt and Qmin ± 5 % ELIN Wasserwerkstechnik Ges.m.b.H. Hainburgerstraße 33, A-1030 Wien Tel.: +43(0)1/ Fax: +43(0)1/ export@ewt.at
4 CORONA MWI 109 Multi-Jet Meter Wet Runner APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output 1 l/pulse (inductive). CORONA MWI can be externed in any way - with IZAR RADIO COMPACT 868 I (radio module) or IZAR PULSE I (pulse transmitter) 4 Extremely low pressure loss and considerably extended measuring range 4 Records very small amounts of water consumption 4 Maximum long-term accuracy and absolutely corrosion-resistant 4 Measuring data better than specified by calibration regulations 4 Strainer insert in inlet connection for cleaning without damaging the seal 4 Capable of withstanding any load for a short time 4 Fine adjustment by regulating plug
5 CORONA MWI 109Meter for horizontal pipes Multi-Jet Meter Wet Runner GENERAL Meter for horizontal pipes Medium temperature range C Temperature safety C Ambient operating temperature C Ambient storage temperature C Nominal pressure PN bar 16 Display range 0.05 l... 99,999 m³ Pulse value l/pulse 1 Protection class IP 68 TECHNICAL DATA Nominal flow rate Q3 m³/h Nominal diameter DN mm Overload flow rate Q 4 m³/h Transition flow rate Q 2 l/h Minimum flow rate Q 1 l/h Starting flow rate l/h 4 4 Pressure loss at Q 3 bar Flow rate at 1 bar pressure loss m³/h APPROVAL Nominal flow rate Q3 m³/h Nominal diameter DN mm MID TH 8627 TH 8627 Dynamic range horizontal installation (Q 3/Q 1) R 40 / 80 / / 80 / 100 / 160 Dynamic range vertical installation (Q 3/Q 1) R
6 CORONA MWI 109Meter for horizontal pipes Multi-Jet Meter Wet Runner DIMENSIONS Nominal flow rate Q3 m³/h Nominal diameter DN mm Overall length (DIN ISO 4064) L mm 165 / Overall length with coupling L2 mm Connection thread on meter (ISO 228/1) Inch G¾B G1B Connection thread of coupling (DIN 2999) Inch R½ R¾ Height H mm Height H1 mm Diameter Ø B mm Weight without coupling kg Weight with coupling kg PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph
7 CORONA MWI 109Meter for rising pipes Multi-Jet Meter Wet Runner GENERAL Meter for rising pipes Medium temperature range C Temperature safety C Ambient operating temperature C Ambient storage temperature C Nominal pressure PN bar 16 Display range 0.05 l... 99,999 m³ Pulse value l/pulse 1 Protection class IP 68 TECHNICAL DATA Nominal flow rate Q3 m³/h 4 Nominal diameter DN mm 20 Overload flow rate Q 4 m³/h 5 Transition flow rate Q 2 l/h 40 Minimum flow rate Q 1 l/h 25 Starting flow rate l/h 4 Pressure loss at Q 3 bar 0.52 Flow rate at 1 bar pressure loss m³/h 5.56 APPROVAL Nominal flow rate Q3 m³/h 4 Nominal diameter DN mm 20 MID TH 8627 Dynamic range vertical installation (Q 3/Q 1) R 40 / 80 / 100 /
8 CORONA MWI 109Meter for rising pipes Multi-Jet Meter Wet Runner DIMENSIONS Nominal flow rate Q3 m³/h 4 Nominal diameter DN mm 20 Overall length (DIN ISO 4064) L mm 105 Overall length with coupling L2 mm 203 Connection thread on meter (ISO 228/1) Inch G1B Connection thread of coupling (DIN 2999) Inch R¾ Height H mm 18 Height H1 mm 108 Diameter Ø B mm 95 Width A mm 82 Weight without coupling kg 1.7 Weight with coupling kg 2.0 PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph
9 Domestic Water Meter Elin Wasserwerkstechnik Contact Water Meter MNM for cold water Features Nominal diameter DN15 to DN50 Cold water up to 30 C (safe up to 50 C) Operating pressure up to 16 bar Control pressure 25 bar Horizontal installation Wet dial multi-jet wheel cold water meter Metrological class B and C (Qn1.5 and 2.5) Very good initial sensibility Excellent measuring results and long stability By order delivery with pulser for required output Possibility for additional pulser use for fixed output The cover lens is made of hardened class Insered filter Possibility for internal flow restrictor utilization The smallest reading value of the counter device is 0.05 litre Plastic based coating of high strength ensures corrosion protection
10 Domestic Water Meter Elin Wasserwerkstechnik Contact Water Meter MNM for cold water Type Nominal diameter DN mm Nominal volumetric flowrate Q n m 3 /h Maximal volumetric flowrate Q max m 3 /h Flowrate at P=1bar m 3 /h Transitional volumetric flowrate Q t l/h ,000 Minimal volumetric flowrate Q min l/h Initial sensibility l/h <8 <10 <8 <10 <15 <15 <15 <45 <45 Metrological class C B C B B Displayed min. quantity l 0.05 Displayed max. quantity m Built-in length L mm Connecting thread R zoll G 3/4 G 1 G 1 1/4 G 1 1/2 G 1 1/2 G 2 G 2 1/2 G 1 1/4 G 1 1/4 Sizes H mm MNM h mm g mm Width B mm Weight kg Pulser Impulse values liter/pulse 1 or 10 or 100 or 1,000 Switching component Reed switch, plug type Switch protection Switching voltage U max = 100 V AC/DC Reed Switching current I max = 0,5 A Switching power P max = 0.2 W Pulse duration Switching power P max = 0.2 W at meter stop continous pulse possible Protection IP 65 Minor technical changes may occur in the course of further development. Overall dimensions: B B ELIN Wasserwerkstechnik Ges.m.b.H. Hainburgerstraße 33, A-1030 Wien Tel.: +43(0)1/ Fax: +43(0)1/ export@ewt.at
11 Domestic Water Meter Elin Wasserwerkstechnik Contact Water Meter MNM for cold water Dial: 3 MNM Q n1,5 m /h Klasse B Material: Meter body: Counter device: Cover lens: Other applied material: Brass Plastic Hardened glass Stainless steel Head loss graph MNM Typical error graph MNM Loss of head bar DN 15 DN DN 25 and DN 30 DN 40 DN 50 Error in measurement +5% +2% 0-2% -5% Flow m /h Flow m /h Qmin Q t Q n Q max Measuring error curve: Error limits: In the upper measuring range between Qmax and Qt ± 2 % In the lower measuring range between Qt and Qmin ± 5 % ELIN Wasserwerkstechnik Ges.m.b.H. Hainburgerstraße 33, A-1030 Wien Tel.: +43(0)1/ Fax: +43(0)1/ export@ewt.at
12 CORONA MDI 110 Multi-Jet Meter Dry Runner APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output 1 l/pulse (inductive). CORONA MDI can be externed in any way - with IZAR RADIO COMPACT 868 I (radio module) or IZAR PULSE I (pulse transmitter) 4 Extremely low pressure loss and considerably extended measuring range 4 Records very small amounts of water consumption 4 Maximum long-term accuracy and absolutely corrosion-resistant 4 Measuring data better than specified by calibration regulations 4 Strainer insert in inlet connection for cleaning without damaging the seal 4 Capable of withstanding any load for a short time 4 Fine adjustment by regulating plug
13 CORONA MDI 110Meter for horizontal pipes Multi-Jet Meter Dry Runner GENERAL Meter for horizontal pipes Medium temperature range C Temperature safety C Ambient operating temperature C Ambient storage temperature C Nominal pressure PN bar 16 Display range 0.05 l... 99,999 m³ Pulse value l/pulse 1 Protection class IP 65 TECHNICAL DATA Nominal flow rate Q3 m³/h Nominal diameter DN mm Overload flow rate Q 4 m³/h Transition flow rate Q 2 l/h Minimum flow rate Q 1 l/h Starting flow rate l/h 9 10 Pressure loss at Q 3 bar Flow rate at 1 bar pressure loss m³/h APPROVAL Nominal flow rate Q3 m³/h Nominal diameter DN mm MID TH 8630 TH 8630 Dynamic range horizontal installation (Q 3/Q 1) R 50 / /
14 CORONA MDI 110Meter for horizontal pipes Multi-Jet Meter Dry Runner DIMENSIONS Nominal flow rate Q3 m³/h Nominal diameter DN mm Overall length (DIN ISO 4064) L mm Overall length with coupling L2 mm Connection thread on meter (ISO 228/1) Inch G¾B G1B Connection thread of coupling (DIN 2999) Inch R½ R¾ Height H mm Height H1 mm Diameter Ø B mm Weight without coupling kg Weight with coupling kg PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph
15 CORONA MDI 110Meter for rising pipes Multi-Jet Meter Dry Runner GENERAL Meter for rising pipes Medium temperature range C Temperature safety C Ambient operating temperature C Ambient storage temperature C Nominal pressure PN bar 16 Display range 0.05 l... 99,999 m³ Pulse value l/pulse 1 Protection class IP 68 TECHNICAL DATA Nominal flow rate Q3 m³/h 4 Nominal diameter DN mm 20 Overload flow rate Q 4 m³/h 5 Transition flow rate Q 2 l/h 80 Minimum flow rate Q 1 l/h 50 Starting flow rate l/h 12 Pressure loss at Q 3 bar 0.45 Flow rate at 1 bar pressure loss m³/h 5.77 APPROVAL Nominal flow rate Q3 m³/h 4 Nominal diameter DN mm 20 MID TH 8630 Dynamic range vertical installation (Q 3/Q 1) R 50 /
16 CORONA MDI 110Meter for rising pipes Multi-Jet Meter Dry Runner DIMENSIONS Nominal flow rate Q3 m³/h 4 Nominal diameter DN mm 20 Overall length (DIN ISO 4064) L mm 105 Overall length with coupling L2 mm 203 Connection thread on meter (ISO 228/1) Inch G1B Connection thread of coupling (DIN 2999) Inch R¾ Height H mm 18 Height H1 mm 108 Diameter Ø B mm 95 Width A mm 82 Weight without coupling kg 1.54 Weight with coupling kg 1.86 PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph
17 ALTAIR V3 Rotary Piston Meter APPLICATION ALTAIR water meter is characterized by its versatility. Its large measuring chamber means that it can be used for submetering or as a main meter. Additionally, it is suitable for different types of water. ALTAIR is a modular meter and therefore can be fitted at any time with IZAR RADIO reading system, IZAR DOSING or the pulse emitter IZAR PULSE, gateway to other systems. FEATURES 4 DN 15 to DN 40 4 Start flow rate 2 l/h for DN 15 4 Low head loss 4 Installation in all position 4 New register with modularity "Ha + Ti" 4 Glass/Metal register in option 4 MID to R= High dynamic range
18 ALTAIR V3 Rotary Piston Meter METROLOGICAL DATA Nominal diameter DN mm Length* L mm Nominal flowrate Q 3 m³/h R* Q 3/Q Starting flowrate l/h Min. constructor's flowrate l/h Min. flowrate Q 1 l/h Transition flowrate Q 2 l/h Maximum flowrate Q 4 m³/h Max. constructor's flowrate m³/h * Other value on request APPROVAL ALTAIR V3 MID approval LNE-5582 Alimentarity ACS-WRC-KTW TEMPERATURE AND PRESSURE ALTAIR V3 Medium temperature range C Nominal pressure NP bar 16 DIMENSIONS Nominal diameter DN mm Length* L mm Width B mm Height H mm Thread connections standard inch 3/4" 3/4" 1" 1"1/4 1"1/2 2" Thread connections (in option) inch "1/4 - Weight kg * Other value on request
19 ALTAIR V3 Rotary Piston Meter PRECISION CURVE HEAD LOSS (DELTA P = Q²/KVS²) Nominal diameter DN mm Length* L mm Kvs OPTIONS Pulse emitter IZAR PULSE : 1impulse/liter Non-return valve - Connector pair - Glass copper register
20 AQUARIUS S / RS / P Single-Jet Meter APPLICATION For measuring consumption in apartments and buildings for billing purposes FEATURES 4 Single-jet impeller meter of fully dry-running design with magnetic coupling 4 Modularity with the HYDROMETER system world 4 Excellent starting flow rate 4 Low pressure loss 4 Installation position: horizontal, vertical, riser pipe, downpipe 4 Compact design 4 Rotatable counter 4 Shield against static magnetic fields according to VDDW standard and EN Working pressure 10 bar according to DIN Protection class IP 54
21 AQUARIUS S / RS / P Single-Jet Meter GENERAL AQUARIUS S / RS / P Medium temperature range cold water C Medium temperature range warm water C Nominal pressure PN bar 10 Display range 0.1 l... 9,999 m³/h EC type approval EO 6 30 C D 98 / EC type approval EO 6 90 C D 98 / Metrological class A/B H Protection class IP 54 Note: HYDROMETER single-jet impeller meters are delivered calibrated in accordance with the calibration regulations. (AQUARIUS P with 10 l/pulse cannot be calibrated.) VERSIONS AQUARIUS S AQUARIUS RS AQUARIUS P Nominal flow rate Qn m³/h Overall length L mm AQUARIUS S - radio segment retrofittable AQUARIUS RS - radio segment mounted AQUARIUS P - pulse output l/pulse 10 / / / 100 Note: AQUARIUS S: radio segment IZAR RS 868 or 434 MHz retrofittable AQUARIUS RS: with mounted and configured radio segment IZAR RS 868 or 434 MHz AQUARIUS P: pulse output by reed switch, cable length 2 m LiYY 2 x 0.25 mm², contact rating 24 V ~ 0.2 A, max. cable length m (depending on electrical perturbation). Switching amplifier have to be used at a longer distance
22 AQUARIUS S / RS / P Single-Jet Meter TECHNICAL DATA Nominal flow rate Qn m³/h Overall length L mm Nominal diameter DN mm Maximum flow rate (short-term) Q max m³/h Transition flow rate horizontal Q t l/h Transition flow rate any position Q t l/h Minimum flow rate horizontal Q min l/h Minimum flow rate any position Q min l/h Starting flow rate horizontal l/h Starting flow rate any position l/h Pressure loss at Q n bar DIMENSIONS Nominal flow rate Qn m³/h Overall length L mm Overall length with coupling L2 mm Overall length with tap coupling L2 mm Connection thread on meter Inch G¾B G¾B G¾B G1B Connection thread of coupling Inch R½ R½ R½ R¾ Height H mm Height (AQUARIUS S / P) H1 mm Height (AQUARIUS RS) H1 mm Diameter Ø B mm Weight without coupling kg Weight with coupling kg
23 AQUARIUS S / RS / P Single-Jet Meter PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressore loss graph Typical error graph
WESAN WP WOLTMAN METER
WESAN WP WOLTMAN METER APPLICATION The bulk water meter WESAN WP can be used for measuring volumes of cold water (up to 50 C) in supply lines with high flow at low pressure loss. The measuring chamber
More informationResidential Water Meters
EnergyMetering Residential Water Meters Multi-jet wet dial meters Multi-jet dry dial meters Positive displacement meters AMR-technology All that counts. Technology of the highest standard Quality and reliability
More informationCORONA E ELECTRONIC METER MULTI-JET
APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor
More informationWESAN WP 222. Bulk Water Meter Woltman
APPLICATION The bulk water meter WESAN WP can be used for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. FEATURES 4 For horizontal and vertical installation
More informationT O PA S Applications Features Your benefits
TOPAS Hot water Applications The TOPAS hot water meter is a velocity flowmeter based on the well-established multijet measuring principle. It operates over a wide measuring range and is used in all areas
More informationHYDRUS ULTRASONIC METER
APPLICATION Static ultrasonic water meter for accurate measuring and recording for all applications of water supply. FEATURES 4 Real data communication, open metering telegram 4 Long-term stability under
More informationCORONA ER ELECTRONIC METER MULTI-JET
APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Inbuilt radio module
More informationCONTOIL VZFA/VZOA , versions for higher requirements / applications
CONTOIL VZF/VZO 4...50, versions for higher requirements / applications For applications requiring an increased accuracy of ±0.5 % or better, such as: Measurement of L heating fuel or diesel in testing
More informationWESAN WPV E ELECTRONIC METER WOLTMAN
APPLICATION Meter for measuring heavily fluctuating flow rates. FEATURES 4 Calibratable and exchangeable measuring insert in one unit, suitable for calibration comprising: measuring insert as main meter,
More informationHYDRUS ULTRASONIC METER
HYDRUS APPLICATION Static ultrasonic water meter for accurate measuring and recording for all applications of water supply. FEATURES 4 Ultrasonic water meter with long-term stability under difficult conditions
More informationRAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h
APPLICATION is a fully electronic multi-jets compact heat meter or compact heat and cooling meter with impeller scanning for recording energy and volume data. is equipped with 2 temperature sensors. is
More informationRAY COMPACT ENERGY METER MECHANICAL
APPLICATION Fully electronic compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Highly accurate recording of all billing data in a heating
More informationTOPAS PMW-basic. Customer benefits. Product features
TOPAS PMW-basic The TOPAS PMW-basic product line covers a wide range of applications in hot water measurement. This innovative system offers all types of water measurement right up to data integration
More informationEW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS
EW10 Series Multijet Water Meters DN15 0 FOR COLD AND WARM POTABLE WATER APPLICATIONS CONTENTS PRODUCT DATA Fig. 1. EW100BM / EW101BM Contents... 1 General... 2 Application... 2 Features... 2 Design...
More informationInstallation Instruction Bulk water meter REMOVABLE ELEMENT WOLTMAN COLD (HOT) WATER METER MODEL: LXLC-50~500
REMOVABLE ELEMENT WOLTMAN COLD (HOT) WATER METER MODEL: LXLC-50~500 LXLC(R)-50-200 LXLC(R)-250-300 APPLICATION Measuring the volume of cold (hot) water passing through the pipeline FEATURES Magnet-drive,
More informationSHARKY FS 473 ULTRASONIC FLOW SENSOR
APPLICATION SHARKY FS ultrasonic flow sensor can be used for flow measuring in local and district heating / cooling systems. The measurement principle is static and based on the measurement of the transit
More informationDomestic water meters
EnergyMetering Domestic water meters Multi-jet wet dial meters Multi-jet dry dial meters Multi-jet semi-dry dial meters/roller Protect Cartridge meters All that counts. Cold water meters Hot water meters
More informationELSTER KENT Non-Metalic Products. Meters, Meterboxes & Accessories made from Engineering Plastics
ELSTER KENT Non-Metalic Products Meters, es & Accessories made from Engineering Plastics 1 Accuracy and long-life stem from engineering excellence Locking Device Reading Slot Elster Kent range of non-metallic
More informationVZO Pressure drop curves See Meter data. Option: Reed pulser or RV / IN pulser
VZO 15...50 Technical data 1) Volume display on roller counter, in litres fuel oil meter with threaded or flanged ends for horizontal, vertical or inclined mounting Option: Reed pulser or RV / IN pulser
More informationMetering systems 0483EN October 2013 Metering units for sanitary or service water
08EN October 0 Losses of Pressure The diagram showing losses of pressure is displayed below. For lower flow rate values, dashed lines are valid, due to the effect of the check valve spring.,00 Kv =, Δp
More informationWZMC-402 Ultrasonic Apartment Energy Meters
Product sheet MT8.36 Meter Type WZMC-402 WZMC-402 Ultrasonic Apartment Energy Meters WZMC-402 is used for metering heat in small and medium-sized central heating plants and district heating plants, typically
More informationEW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS
EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS Application PRODUCT DATA Static compact heat meter with electronic measurement, consisting of electronic energy integrator
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationTOPAS PMW-basic Hot water meter
TOPAS PMW-basic Hot water meter Swiss Made Applications The TOPAS PMW-basic product line covers a wide range of applications in hot water measurement. This innovative system offers all types of water measurement
More informationVZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side
VZ-01 Oil Counter for Light to Heavy Fuel Oil Description: Features / Mounting on pressure or suction side The VZ-01 series of volume counters are rotary piston meters that function without auxiliary electrical
More informationMeasuring capsule heat meter G54 / G55
Measuring capsule heat meter G54 / G55 Measuring capsule heat meter with optical interface and external modules for retrofitting. Thanks to integrated modules, the devices can be equipped with the required
More informationBAYLAN AUTOMATED TEST BENCH
BAYLAN AUTOMATED TEST BENCH At this test bench, the electromagnetic flow meters are used with the measurement method. Calibrations of flowmeters are made with the help of the water collection tank and
More informationaquaconcept Product features Customer benefits
aquaconcept The unique aquaconcept modular design covers a wide range of water applications. This innovative system offers all types of water measurement right up to data integration into your specific
More informationVolumeter. RMG Meßtechnik GmbH. Publication No E
Volumeter TRZ 03-K RMG Meßtechnik GmbH Publication No. 3.171-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de
More informationVZFA/VZOA MISURATORI DI PORTATA FUEL OIL METERS. CONTOIL VZFA/VZOA , versions for special requirements / applications
VZFA/VZOA FUEL OIL METERS MISURATORI DI PORTATA CONTOIL VZFA/VZOA 5...50, versions for special requirements / applications For applications requiring an increased accuracy of ± % or better, such as: Versions
More informationApartment water meters
EnergyMetering Apartment water meters Optionally with pulse-output Fittings meters Flush-mounted meters Surface-mounted meters All that counts. Surface-mounted meters Flush-mounted meters Apartment water
More informationWSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.
Woltmann type combined energy meter Flanged Woltmann flow meters for large nominal flows, intended for flow measurements in large plants, such as those found in district heating systems. Size DN50 DN300
More informationFluidic Oscillation Compact Heat Meter
Fluidic Oscillation Compact Heat Meter Application The Superstatic 749 is an autonomous compact thermal energy meter consisting of a flow meter a detachable integrator with a wide range of communications
More informationa q u a c o n c e p t Applications Features Benefits
aquaconcept Cold water Swiss Made Applications The unique aquaconcept modular design covers a wide range of water applications. This innovative system offers all types of water measurement right up to
More informationSuperstatic 749. Fluidic Oscillation Compact Heat Meter
Superstatic 749 Fluidic Oscillation Compact Heat Meter Application The Superstatic 749 is an autonomous compact thermal energy meter consisting of a flow meter an integrator and a pair of temperature sensors.
More informationMidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin
MidFlow Model PT / Fuel Oil Flowmeters135 Sliding Vane Meters DN 25-50 (1-2 ) _ 135 Product Bulletin WWW.VAF.NL 1 Introduction VAF Instruments MidFlow Model PT positive displacement sliding vane type liquid
More informationWATER METERS.
WTER METERS Hydrodynamic design High protection Multi-jet technology ensures uniform distribution of load on the turbine located thanks to the water inlet diffuser. The movement activates the magnetic
More informationQuantometer MZ. Description
Quantometer MZ < High accuracy budget meter < Flow rate up to 10000 m 3 /h < Pressure range up to 100 bar < Equipped as standard with the cyble target. < Various options available: Low and high frequency
More informationCONTOIL Fuel oil meters
CONTOIL Fuel oil meters Applications Flow measurement of mineral oils for heaters and fixed installations. VD 4-410 e 07.2012 Features Classical version with mechanical display State-of-the-art design
More informationWSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.
revision 04 2015 Woltmann type combined energy meter Woltmann flow meters for large nominal flows combined with calculator and temperature sensors. The WSTH and WPTH meters are designed for flow measurements
More informationS 100 Single-jet Water Meter Unobtrusively upmarket just what it should be
S 00 Single-jet Water Meter Unobtrusively upmarket just what it should be > Domestic Water Meter Type EV, optionally with pulse output Type EV-A prepared for remote acquistion. Nominal flow rate Q n.5...
More informationCONTOIL Fuel oil meters
CONTOIL Fuel oil meters Applications Flow measurement of mineral oils such as heating or propellant fuels In burners, on board ships, land vehicles and fixed installations Marine and metrological type
More informationAvailable in sizes DN 25, 30, 40 and 50 mm, Multimag TM is a class B multi-jet turbine meter for commercial and industrial applications.
Multimag TM Multi-jet Turbine Water Meter DN 25 to DN 50 mm haracteristics Velocity type meter Direct magnetic transmission lass ISO 4064 vailable in sizes DN 25, 30, 40 and 50 mm, Multimag TM is a class
More informationRMG Meßtechnik GmbH. Publication No E
Turbine meter TRZ 03 RMG Meßtechnik GmbH Publication No. 3.161-E P.O.Box 80 D-3550 Butzbach (Germany) Phone: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Web site: http://www.rmg.de
More informationSuperstatic 440. Static Heat Meter, Static Cooling Meter. Application
Superstatic 440 Static Heat Meter, Static Cooling Meter Application Design The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,
More informationWater Metering THE WORLD S MOST ACCURATE COMMERCIAL HYBRID METER
Water Metering THE WORLD S MOST ACCURATE COMMERCIAL HYBRID METER H5000: The World s Most Accurate Commercial Hybrid Meter The H5000 s true hybrid design has the widest measuring range of any water metering
More informationVolumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas
Volumeter TRZ 0-K PRODUCT INFORMATION Reliable Measurements of Gas Method of operation, Construction Method of operation The TRZ 0-K Volumeter is a flow meter suitable for metering gases, where the rate
More informationMake sure that no hazardous fumes can build up in the piping and in the meter during commissioning, decommissioning and dismantling.
The device and its accessories must only be used for their intended purpose and comply with safety regulations. Aquametro devices are manufactured according to valid standards and guidelines. Aquametro
More informationS 100 Single-jet Water Meter Unobtrusively upmarket just what it should be
S 100 Single-jet Water Meter Unobtrusively upmarket just what it should be > Domestic Water Meter Type EV, optionally with pulse output Type EV-A prepared for remote acquistion. Nominal flow rate Q n 1.5...
More informationSonoMeter 30 Energy Meters
SonoMeter 30 Energy Meters Description MID examination certificate no.: LT-1621-MI004-020 The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption
More informationElectronic Water Meters in measuring cell design
5 343 SIEMECA Electronic Water Meters in measuring cell design WMC... WMH... Electronic, mains-independent meters to acquire water consumption in autonomous domestic water plants. Storage and display of
More informationElectronic Water Meters
5 341 Electronic Water Meters WFC... WFH... Electronic, mains-independent meters to acquire water consumption in autonomous domestic water plants. Storage and display of the cumulated consumption values
More informationSonoMeter 30 Energy Meters
SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications for billing
More informationSonoSensor 30 Ultrasonic flow sensor
Data Sheet SonoSensor 30 Ultrasonic flow sensor Description MID examination certificate no.: LT-1621- MI004-030 SonoSensor 30 is an ultrasonic flow sensor especially designed for heating, cooling or combined
More informationCompact Static Heat Meter of High-Tech Composite
Compact Static Heat Meter of High-Tech Composite Application The Superstatic 789 is a lightweight and robust compact heat meter consisting of a high-tech composite flow meter, a detachable integrator with
More informationTechnical Information
Technical Information Water meters Apartment water meters Modularis M-Bus module Connecting pieces and accessories Domestic water meters Rossweiner Armaturen und Messgeräte GmbH & Co. ohg Wehrstraße 8
More informationFluidic Oscillation Compact Heat Meter of High-Tech Composite
Superstatic 789 Fluidic Oscillation Compact Heat Meter of High-Tech Composite Application The Superstatic 789 is an autonomous compact thermal energy meter consisting of a high-tech composite flow meter
More informationCOVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information
Durchflussmessung Flowmeters COVOL Areas of Application Operating Data Method of Operation Oscillating Piston Operating pressure, max. PN 10 (Plastic) PN 16 (Stainless Steel) Fields of operation Consumption
More informationDelta Commercial & Industrial Rotary Meter
Delta Commercial & Industrial Rotary Meter Itron's Delta range of rotary gas meters comprises innovative and high quality products. Characterized by compact dimensions and easy maintenance, the Delta
More informationWATER METERS.
WATER METERS Design Hydrodynamic Mechanism Independent The operation of the Hydrotangential meter is based on a turbine at the top of the meter, which allows the solid particles go through without obstructing
More informationCONTOIL Fuel oil meters
CONTOIL Fuel oil meters Applications Flow measurement of mineral oils for heaters and fixed installations. VD 4-410 e 11.2012 Features Classical version with mechanical display State-of-the-art design
More informationF 90 Heat Meter Warmly recommended to cool-headed economisers
F 90 Heat Meter Warmly recommended to cool-headed economisers Available in three types for a multitude of job profiles. PICOTHERM 2e the economy heat meter without data outputs. PICOTHERM 2 the compact-size
More informationAbsolute pressure gauge with diaphragm
Absolute pressure gauge with diaphragm and switch function,type series BF2 Features Absolute pressure gauge with diaphragm and switch function Nominal ranges 0 60 mbar abs to 0 2500 mbar abs With integrated
More informationInline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )
EE771/EE772 Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the
More informationtprime TM Series 280T
MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.
More informationMULTICAL 62 DATA SHEET. Application
Ultrasonic flow sensor Pinpoint measuring accuracy No wear and long lifetime Complete range of communication modules Up to 13 years battery lifetime MID-2004/22/EC M12 0200 Application MULTICAL 62 is an
More informationBGN. All Metal Variable Area Flow Meter. Technical Data Sheet
All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of
More informationScrew-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.
Data sheet DST2-QHEA-GB0 HMx / 11.05.2016 - V 1.0 Heat meter Q heat 5 Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated
More informationULTRASONIC HEAT METER
MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.
More informationThe Kent Range of Metering Products. Product Range Overview. Elster Metering
The Kent Range of Metering Products Product Range Overview Elster Metering Domestic cold s V100 Volumetric cold s The V100 is the world s favourite domestic, with over 50 million already in service in
More informationFluxi 2000/TZ Turbine Gas Meter
Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas. The
More informationPrecision Bourdon tube pressure gauges
Pressure gauges Precision pressure gauges High accuracy (class 0.6) Housing can be plumbed Serial number on dial Suitable as measuring equipment as per QA requirements DNV- and GOSSTANDART-certified A
More informationSupercal 539. Compact thermal energy meter
Supercal 539 Compact thermal energy meter Application Electronic, battery-powered compact thermal energy meter intended to record heat consumption in autonomous heating systems or combined heating/cooling
More informationPressure transmitter COMPACT ECOnomic
Pressure transmitter COMPACT ECOnomic for food/pharmaceutical/biotechnology, Type series CA1110 Features Digitale pressure transmitter Hygienic design according to EHEDG Case and wetted parts of stainless
More informationDelta Commercial & Industrial Rotary Meter
Delta ommercial & Industrial Rotary Meter Delta meters are volumetric meters. The fl ow of gas moves the pistons and each rotation traps and transfers a specifi c volume of gas. The movement is mechanically
More informationElectronic Water Meters
5 328 SIEMECA Electronic Water Meters WFC WFH Electronic, mains-independent meters to acquire water consumption in autonomous domestic water plants. Storage and display of the cumulated consumption values
More informationPressure transmitters for heavy duty applications MBS 8200 and MBS 8250
Data sheet Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250 MBS 8200 is a series of compact pressure transmitters developed to withstand the pressure pulsations and vibrations known
More informationDatasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.
Datasheet Ultrasonic Flow Sensors & Integrator Technical Overview Ultrasonic flow sensors have no moving parts in the volume flow, this makes them almost wear free and noiseless. They measure the flow
More informationOPTIFLUX 6000 Technical Datasheet
OPTIFLUX 6000 Technical Datasheet Electromagnetic flow sensor for hygienic and sanitary applications Robust stainless steel housing for hygienic and aseptic operation Fully suitable for CIP and SIP Typical
More informationAbsolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and
Pressure Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models 532.52, 532.53 and 532.54 WIKA data sheet PV 25.02 for further approvals see page 4 Applications Control
More informationProFlow TO BE REALLY SURE. Vane Meters. Experience in flow measurement. Introduction
ProFlow N142 P R O D U C T B U L L E T I N Vane Meters Special versions This brochure comprises only VAF Instruments standard delivery program. Special flowmeter variants can be offered as tailor-made
More informationFlowmeter MDW 500. description. 230 VAC (50/60 Hz), 24 VAC/VDC with polarity reversal protection, 110VAC(60Hz) on request
description - industrial inductive flow meter with display unit - innovative and compact connection head design - measurement of different liquids in a variety of sectors - various process connections
More informationOscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids
Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions
More informationTechnical Datasheet. HM AC Series. Turbine Flow Meters. for High Pressure Applications up to 1,400 bar
www.kem-kueppers.com info@kem-kueppers.com Technical Datasheet HM AC Series Turbine Flow Meters for High Pressure Applications up to 1,400 bar Certified according to DIN EN ISO 9001 2 HM AC Series Turbine
More informationULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2
AB AXIS INDUSTRIES ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2 TECHNICAL DESCRIPTION, INSTALLATION AND USER INSTRUCTIONS PESF2V01 KAUNAS Contents Page SAFETY INFORMATION... 1. APPLICATION FIELD... 2. TECHNICAL
More informationSuperstatic 440. Static Heat- and Cooling Meter. Application
Superstatic 440 Static Heat- and Cooling Meter Application Design The Superstatic 440 is a static heat- and cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,
More informationTechnical Data B20x. 8 BiRotor, APL. Model B201 [8 ] Model B203 [8 ] Model B204 [8 ] Model B205 [8 ]
Technical Data BiRotor, APL Model B201 [] Model B203 [] Model B204 [] Model B205 [] General The BiRotor Meter is a positive displacement meter utilized in the most demanding applications requiring accuracy,
More informationUS-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability
Revision 2017-08-15 Ultrasonic energy meters Flanged ultrasonic energy meters, intended for heating or cooling. Size DN25 DN100 Nominal flow 3.5 60 m³/h For horizontal or vertical mounting No data loss
More informationSTUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600
STUF-280W Features: Wear-free ultrasonic measurement. No moving parts. No maintenance needed Proprietary robust sensor design. Not impacted by water impurity Counts each drop. Very low start flowrate Excellent
More informationAccurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre
Inline Flowmeter for compressed air and gases DN15 - DN50 / 16 bar The flow meter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow of
More informationCOMPONENTS FOR SOLAR THERMAL SYSTEMS
COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending
More informationDOMINO Flow meters for chemical liquids DN
DOMINO Flow meters for chemical liquids DN 15...50 AM066168 AM066139 AM066169 Flow measurement of liquids in chemical, pharmaceutical, cosmetic and other industries. Batching and filling operations. VD
More information2-port and 3-port ball valves PN 40
s 4 211 VAI61.. VBI61.. ACVATIX TM 2-port and 3-port ball valves PN 40 with internally threaded connections VAI61.. VBI61.. Brass UNS C35330 (DZR) ball valve body DN 15...50 k vs 1...63 m 3 /h Internally
More informationM SERIES Multi-Jet Cold Water Meter
M SERIES Multi-Jet Cold Water Meter /4 1 1-1/2" 2" Maximum Flow GPM 0 0 1 Minimum Flow GPM.2.7 1. 2.0 Maximum Operating Pressure 0 psi Maximum Operating Temperature F ( C) Also Available in Hot Water Applications
More informationMagFlux Q 8200 Series
MagFlux Q 8200 Series 3.06 ELECTROMAGNETIC FLOW METER General MagFlux Q Electromagnetic Flow Meter, created in composite materials, designed with an optimized construction which secures optimal performance.
More informationDMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 bar up to 0... 600
More informationWATERFLUX 3000 Technical Datasheet
WATERFLUX 3000 Technical Datasheet Electromagnetic flowmeter Easy installation without straight inlet or outlet lengths For installation in small spaces Wide range of approvals for potable water The documentation
More informationChapter 06 Accessories ACCESSORIES
ccessories CCESSORIES 57 Powerful and precise Input, 3-pole Output is 3-pole + N Use in IT networks without neutral line For reducing the measurement voltage for the UMG measurement input Use in IT networks
More informationOPTIFLUX Electromagnetic Flow Sensor
OPTIFLUX 2000 Technical Datasheet Electromagnetic Flow Sensor Engineered and manufactured for the water and wastewater industry All relevant approvals for potable water Long-term reliability and durability
More informationData sheet: Wilo-Economy MHI 202 (3~400 V, EPDM)
Data sheet: Wilo-Economy MHI 22 (3~4 V, EPDM) Pump curves P 2 [kw] NPSH [m] H[m] 7 26 Wilo-Economy-MHI 22-26 5 Hz 6 25 5 24 4 3 23 2 22,5,5 2 2,5 3 3,5 4 4,5 5 5,5,5,5 [l/s] 5 5 4 4 3 3 2 2 NPSH,5,5 2
More information