WZMC-402 Ultrasonic Apartment Energy Meters
|
|
- Sylvia Marsh
- 5 years ago
- Views:
Transcription
1 Product sheet MT8.36 Meter Type WZMC-402 WZMC-402 Ultrasonic Apartment Energy Meters WZMC-402 is used for metering heat in small and medium-sized central heating plants and district heating plants, typically in single or multi-family houses and in blocks of flats. The meter is very simple to install, read and verify. In addition, WZMC-402 contributes to keeping the annual operating costs at a minimum with its unique combination of large measuring accuracy and long lifetime. WZMC-402 calculates the thermal energy based on the measured differential temperature between flow and return flow, the measured water quantity, as well as internal table correction for density and enthalpy. Flow is measured with ultrasound according to the transit time method, and all measurements, references, display readings, calculations and data communication are controlled by a microprocessor and an ASIC. In addition, WZMC-402 totalizes the consumption of 2 water meters with pulse output, and thereby a total reading of thermal energy and tap water consumption is obtained. Via an internal module WZMC-402 can be remotely read by means of RS232, M-Bus, modem or radio system. Model Type Model Description WZMC Ultrasonic Heat Meter, DN15 G¾B, Screwed up to 0.6m3/h, Valve Body 110mm. Incl. Pt500 Sensor Set with 1.5m Cable, 2 Stainless Steel Pockets WZMC Ultrasonic Heat Meter, DN15 G¾B Screwed up to 1.5m3/h, Valve Body 110mm. Incl. Pt500 Sensor Set with 1.5m Cable, 2 Stainless Steel Pockets WZMC Ultrasonic Heat Meter, DN20 G1B Screwed up to 3.0m3/h, Valve Body 130mm. Incl. Pt500 Sensor Set with 1.5m Cable, 2 Stainless Steel Pockets WZMC Ultrasonic Heat Meter, DN25 G11/4B Screwed up to 3.5m3/h, Valve Body 260mm. Incl. Pt500 Sensor Set with 1.5m Cable, 2 Stainless Steel Pockets WZMC Ultrasonic Heat Meter, DN25 G11/4B Screwed up to 6.0m3/h, Valve Body 260mm. Incl. Pt500 Sensor Set with 1.5m Cable, 2 Stainless Steel Pockets WZMC Ultrasonic Heat Meter, DN40 G2B Screwed up to 10.0m3/h, Valve Body 300mm. Incl. Pt500 Sensor Set with 1.5m Cable, 2 Stainless Steel Pockets OPTIONS (please select) Power Supply: Battery, 24Vac or 230Vac Power Supply Communication: Impulse Output or M-Bus Sensors: Standard 1.5m Cable, Upgrade to 3.0m Couplings: As required PS MT8.36-1/5
2 Features "Long-Life" Ultrasonic Heat Meter Large Dynamic Range 12 years of battery operation, or 24VAC or 230VAC Power Supply M-Bus Data Communication Option 2 Pulse Inputs for Water Meters (with M-Bus option) Pulse Output for Energy MID Approval Optical Data Reading Option Technical Data - Electrical Display LCD Display with 7 Digits Remote Communication Options Battery Impulse Output M-bus (according to EN ) Lithium 3.65VDC D-cell Lithium Replacement Interval Mounted on the wall: 12 Tbat < 30 C Flow sensor mounted: Tbat < 40 C Fast Mode: Tbat < 30 C Back-Up Supply Integral super-cap eliminates operational disturbances due to short-term power cuts Mains Supply (Options) Amb Temperatures Protection Class Dimensions 230VAC +15/-30%, 50Hz 24VAC +/-50% C IP54 W118 x H144 mm Mechanical Metrological Class 2 and 3 Certification EN 1434 Class A Nominal Pressure PN16 Installation Horizontal / Vertical / At an Angle Temperature Medium Water C (Above 90 C flanged meters recommended. Mount calculator on wall) Temperature Sensors Type Pt500 EN60751 Cable Length 1.4m (as standard), 3.0m cable on request M-Bus Interface Interface M-bus accordance with EN Readable Data Serial number, energy value, cut-off date value, volume, flow rate, heating power, supply and return temperature, temperature difference, pulse input counter values Accessories and Options Model Description WZMC-402-BAT Battery Power Supply WZMC V 24VAC Power Supply WZMC V 230VAC Power Supply WZMC-402-M-BUS M-Bus Communication Module with Pulse Inputs WZMC-402-IMP Data/Pulse Output Module (pulse output for secondary energy CE) WZMC-402-SEN m Pt500 Sensor Upgrade WZMC-402-CON-DN15 G¾B to R1/2" Coupling Set WZMC-402-CON-DN20 G1B to R3/4" Coupling Set WZMC-402-CON-DN25 G11/4B to R1" Coupling, Single WZMC-402-CON-DN40 G2B to R11/2" Coupling, Single Detailed Description WZMC-402 is a static, ultrasonic thermal heat meter, designed for measuring energy in all types of heating installations where water is used as the heat-conveying medium. According to EN 1434 WZMC-402 can be described as a "hybrid instrument" also called a "compact meter". In practice this means, that flow part and calculation unit must not be separated. If flow part and calculation unit have been separated and the seals thereby have been broken, the meter will no longer be valid for billing purposes, and the factory guarantee will no longer apply. PS MT8.36-2/5
3 Ultrasonic measuring and microprocessor technology are the foundation of the energy meter. All circuits for calculating, measuring temperature and flow are combined in a single board construction, which not only gives a compact and rational design but also ensures an optimal measuring quality and a high degree of reliability. Bidirectional, ultrasonic technique is used to measure the volume, based on the transit time method. A method which is widely recognised as being the best measuring principle currently available for this type of application owing to the long-term stability. Two ultrasonic transducers send sound signals both against and with the flow direction. The ultrasonic signal travelling with the flow reaches the opposite transducer before the signal travelling against the flow. The time difference between receiving the two signals is converted into a flow quantity. Accurately paired Pt500 sensors (in accordance with EN 60751) measure the temperature in the flow and return pipes. The short direct sensor construction is designed in accordance with EN and is, therefore, suitable for installation in a wide range of standard ball valves and fittings. In connection with union meters G1 one temperature sensor can be fitted directly into the flow part, thereby simplifying the installation. The accumulated thermal energy can be displayed in kwh, MWh or GJ all shown in seven digits with the measuring unit. The display has been specially designed with a view to longevity and optimal contrast in ambient temperatures ranging from C. Other values displayed include accumulated water consumption, operation hour counter, actual temperature measurement and momentary flow and power measurements. WZMC-402 can also be configured to record target date, peak power, information code, actual date and user-defined tariffs. To maximise safety, all registers are stored at hourly intervals in an EEPROM, which also stores monthly data for the previous two-year period. WZMC-402 has two ports for data communication. The optical eye on the front panel complies with EN standard and facilitates reading of consumption data, data logger and on-line serial PC-connection when configuring the energy meter.a split multiplug is placed beneath the top cover. The top part of this plug is used to verify the meter. The lower part is used when connecting communication modules such as M-Bus. Meter Flow Information Part No Nominal Flow Max. Flow Min Flow (l/h) Min. Cut Off (lh) Pressure Loss qp bar) WZMC G3/4B 110 WZMC G3/4B 110 WZMC G1B 130 WZMC G11/4B 260 WZMC G11/4B 260 WZMC G2B 300 Length Accuracy The accuracy of the parts of the unit are stated as below:- Sub-Units of the Heat Meter MPE According to EN MC402, Typical Accuracy Flow Senso ±( qp/p)% ±( qp/p)% Calculator ±(0.5 + dt min/dt)% ±( /dt)% Sensor Set ±( dt min/dt)% ±( /dt)% PS MT8.36-3/5
4 WZMC-401 qp dt 30K EN WZMC-401 HM WZMC-401 typical accuracy compared to EN Volume Device Installation The WZMC volume part may be installed horizontally, vertically or at an angle. The plastic calculator box must NOT be mounted facing upwards. WZMC volume part can be mounted horizontally, vertically or at any angle. WZMC volume part can turn up to max. 45 upwards and down to 90 downwards in relation to the pipe axis. WZMC must NOT be mounted the plastic box facing upwards. Volume Device Dimensions (DN15 and DN20) Nom Size L M H2 A B1 B2 H1 WZMC DN15 G3/4 110 L/ WZMC DN15 G3/4 110 L/ WZMC DN20 G1 130 L/ Weight (kg) PS MT8.36-4/5
5 Nom Size L M H2 A B1 B2 WZMC DN25 G11/4 260 L/ WZMC DN25 G11/4 260 L/ Weight (kg) Pressure Drop Curve 1 Dp WZMC-401 Pressure Drop A B C p[bar] 0,1 0,01 0, Flow [m³/h] Graph Nom Size Kv Q@0.25bar A 0.6 & 1.5 DN15 & DN B 3 & 3.5 & 6.0 DN20 & DN C 10 DN PS MT8.36-5/5
SonoMeter 30 Energy Meters
SonoMeter 30 Energy Meters Description MID examination certificate no.: LT-1621-MI004-020 The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationSonoMeter 30 Energy Meters
SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications for billing
More informationFluidic Oscillation Compact Heat Meter
Fluidic Oscillation Compact Heat Meter Application The Superstatic 749 is an autonomous compact thermal energy meter consisting of a flow meter a detachable integrator with a wide range of communications
More informationSupercal 539 Universal compact heat meter
n Thermal Energy n Flow Metering n Supercal 539 Universal compact heat meter Universal compact heat meter Result of many years of experience The compact heat meter Supercal 539 is the result of many years
More informationMULTICAL 62 DATA SHEET. Application
Ultrasonic flow sensor Pinpoint measuring accuracy No wear and long lifetime Complete range of communication modules Up to 13 years battery lifetime MID-2004/22/EC M12 0200 Application MULTICAL 62 is an
More informationHYDRUS ULTRASONIC METER
HYDRUS APPLICATION Static ultrasonic water meter for accurate measuring and recording for all applications of water supply. FEATURES 4 Ultrasonic water meter with long-term stability under difficult conditions
More informationSuperstatic 440. Static Heat Meter, Static Cooling Meter. Application
Superstatic 440 Static Heat Meter, Static Cooling Meter Application Design The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,
More informationCompact Static Heat Meter of High-Tech Composite
Compact Static Heat Meter of High-Tech Composite Application The Superstatic 789 is a lightweight and robust compact heat meter consisting of a high-tech composite flow meter, a detachable integrator with
More informationHYDRUS ULTRASONIC METER
APPLICATION Static ultrasonic water meter for accurate measuring and recording for all applications of water supply. FEATURES 4 Real data communication, open metering telegram 4 Long-term stability under
More informationRAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h
APPLICATION is a fully electronic multi-jets compact heat meter or compact heat and cooling meter with impeller scanning for recording energy and volume data. is equipped with 2 temperature sensors. is
More informationHello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.
Hello, I am the new Zelsius C5 heat meter The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement. zelsius C5 Ultrasonic Energy Meter About The ZENNER C5 Ultrasonic
More informationUS-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability
Revision 2017-08-15 Ultrasonic energy meters Flanged ultrasonic energy meters, intended for heating or cooling. Size DN25 DN100 Nominal flow 3.5 60 m³/h For horizontal or vertical mounting No data loss
More informationSuperstatic 749. Fluidic Oscillation Compact Heat Meter
Superstatic 749 Fluidic Oscillation Compact Heat Meter Application The Superstatic 749 is an autonomous compact thermal energy meter consisting of a flow meter an integrator and a pair of temperature sensors.
More informationtprime TM Series 280T
MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.
More informationSHARKY FS 473 ULTRASONIC FLOW SENSOR
APPLICATION SHARKY FS ultrasonic flow sensor can be used for flow measuring in local and district heating / cooling systems. The measurement principle is static and based on the measurement of the transit
More informationData sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434
Data sheet MULTICAL 6L2 Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434 M15 0200 Contents Calculator functions 3 Cabinet design 7 Approved meter data 8 Electrical
More informationULTRASONIC HEAT METER
MEASURE TODAY. ENSURE TOMORROW. tprime TM Series 280T Applications Residential submetering Commercial buildings District heating / cooling HVAC Green energy management AMR and Billing Features Wear-free.
More informationRAY COMPACT ENERGY METER MECHANICAL
APPLICATION Fully electronic compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Highly accurate recording of all billing data in a heating
More informationFluidic Oscillation Compact Heat Meter of High-Tech Composite
Superstatic 789 Fluidic Oscillation Compact Heat Meter of High-Tech Composite Application The Superstatic 789 is an autonomous compact thermal energy meter consisting of a high-tech composite flow meter
More informationSupercal 539. Compact thermal energy meter
Supercal 539 Compact thermal energy meter Application Electronic, battery-powered compact thermal energy meter intended to record heat consumption in autonomous heating systems or combined heating/cooling
More informationCORONA E ELECTRONIC METER MULTI-JET
APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor
More informationSuperstatic 440. Static Heat- and Cooling Meter. Application
Superstatic 440 Static Heat- and Cooling Meter Application Design The Superstatic 440 is a static heat- and cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,
More informationCORONA ER ELECTRONIC METER MULTI-JET
APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Inbuilt radio module
More informationSonoSensor 30 Ultrasonic flow sensor
Data Sheet SonoSensor 30 Ultrasonic flow sensor Description MID examination certificate no.: LT-1621- MI004-030 SonoSensor 30 is an ultrasonic flow sensor especially designed for heating, cooling or combined
More informationWSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.
Woltmann type combined energy meter Flanged Woltmann flow meters for large nominal flows, intended for flow measurements in large plants, such as those found in district heating systems. Size DN50 DN300
More informationMULTICAL 6M2. Data sheet
Data sheet MULTICAL 6M2 Tailored for mixed fluids Data loggers Info loggers Data backup in case of power failure Measurement at subzero temperatures Configurable fluid type and concentration level Contents
More informationEW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS
EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS Application PRODUCT DATA Static compact heat meter with electronic measurement, consisting of electronic energy integrator
More informationMeasuring capsule heat meter G54 / G55
Measuring capsule heat meter G54 / G55 Measuring capsule heat meter with optical interface and external modules for retrofitting. Thanks to integrated modules, the devices can be equipped with the required
More informationDatasheet. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)
Datasheet Multical 402 (Heating & Cooling) Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Data sheet MULTICAL 402 Up to 16 years battery lifetime Set/reset function Pulse outputs
More informationMetering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series
Version A Version B GE552-1 Description The GE552-2 meters are thermal energy meters with double register and ultrasound,. They enable the measurement of energy used for heating and air-conditioning. They
More informationScrew-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.
Data sheet DST2-QHEA-GB0 HMx / 11.05.2016 - V 1.0 Heat meter Q heat 5 Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated
More informationIFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0
IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0 Table of contents PRINCIPLE... 4 HOW TO ORDER... 4 TECHNICAL DATA... 5 Table 1.1... 6 Table 1.2... 7 Table 1.3... 7 Straight pipelines lengths... 7 Conveying liquid...
More informationHorizontal Distribution Units - HDU Multi-port
Application Danfoss pre-fabricated HDU distribution units are made for distribution and measuring of waterbased heating in 2-pipe horizontal systems. A HDU is easily mounted on the apartment wall and connected
More informationWESAN WPV E ELECTRONIC METER WOLTMAN
APPLICATION Meter for measuring heavily fluctuating flow rates. FEATURES 4 Calibratable and exchangeable measuring insert in one unit, suitable for calibration comprising: measuring insert as main meter,
More informationMULTICAL 602. & ULTRAFLOW 14 Cooling. Cooling meter with unlimited communication
MULTICAL 602 & ULTRAFLOW 14 Cooling data sheet Complete range of communication modules High Power RadioRouter module Data loggers Info loggers Data backup in case of power failure Cooling meter with unlimited
More informationUltrasonic heat meter
Ultrasonic heat meter Installation and user guide Flow sensor-vmc-p Energy integrator Compact heat meter Temperature senor CONTENTS Kapitel Please read this manual prior to installation Page 3 2! T! Important
More informationSTUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600
STUF-280W Features: Wear-free ultrasonic measurement. No moving parts. No maintenance needed Proprietary robust sensor design. Not impacted by water impurity Counts each drop. Very low start flowrate Excellent
More informationDatasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.
Datasheet Ultrasonic Flow Sensors & Integrator Technical Overview Ultrasonic flow sensors have no moving parts in the volume flow, this makes them almost wear free and noiseless. They measure the flow
More informationInstallation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)
Installation & Maintenance Instructions MULTICAL 403 Supplied by.com Call us on +44 (0)118 916 9420 Email info@ Installation and user s guide MULTICAL 403 1 Information Permissible operating conditions
More informationWSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.
revision 04 2015 Woltmann type combined energy meter Woltmann flow meters for large nominal flows combined with calculator and temperature sensors. The WSTH and WPTH meters are designed for flow measurements
More informationF 90 Heat Meter Warmly recommended to cool-headed economisers
F 90 Heat Meter Warmly recommended to cool-headed economisers Available in three types for a multitude of job profiles. PICOTHERM 2e the economy heat meter without data outputs. PICOTHERM 2 the compact-size
More informationEW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS
EW10 Series Multijet Water Meters DN15 0 FOR COLD AND WARM POTABLE WATER APPLICATIONS CONTENTS PRODUCT DATA Fig. 1. EW100BM / EW101BM Contents... 1 General... 2 Application... 2 Features... 2 Design...
More informationDomestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features
Domestic Water Meter Elin Wasserwerkstechnik Contact Water Meter MTM for cold water Features Nominal diameter DN15 to DN50 Cold water up to 30 C (safe up to 50 C) Operating pressure up to 16 bar Control
More informationSITRANS FUE950 *085R9430* Energy calculator type SITRANS FUE950. Operating Manual Edition 09/ Revision 03
s Operating Manual Edition 09/2006 - Revision 03 SITRANS FUE950 Energy calculator type SITRANS FUE950 District heating application Chilled water application Combined cooling/heating application [ ] Order
More informationULTRASONIC METER FOR HEATING AND COOLING SKU-03
AB AXIS INDUSTRIES ULTRASONIC METER FOR HEATING AND COOLING SKU-03 BASIC TECHNICAL DESCRIPTION KAUNAS Contents SAFETY INFORMATION... 1.APPLICATION FIELD... 2.TECHNICAL DATA... 3.OPERATION PRINCIPLE...
More informationULTRASONIC FLOW SENSOR IFX-M4-01
ULTRASONIC FLOW SENSOR IFX-M4-01 TECHNICAL DESCRIPTION, OPERATING INSTRUCTION IFX-M4-01 2012-09-10 TABLE OF CONTENTS 1. APPLICATION... 3 2. TECHNICAL DATA... 4 3. PACKAGE CONTENT... 6 4. OPERATING PRINCIPLE...
More informationM-bus impeller type heat and heat/refrigeration meters
Metering M-bus impeller type heat and heat/refrigeration meters WF..5.. Electronic, mains-independent impeller type meters with optional refrigeration range to acquire heat or cooling energy consumption
More informationHeating and Cooling Catalog
Heating and Cooling Catalog KNOWLEDGE TO SHAPE YOUR FUTURE At Itron, the phrase «Knowledge to shape your future» is more than a simple slogan. It s a fundamental tenet of who we are, and it helps define
More informationULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2
AB AXIS INDUSTRIES ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2 TECHNICAL DESCRIPTION, INSTALLATION AND USER INSTRUCTIONS PESF2V01 KAUNAS Contents Page SAFETY INFORMATION... 1. APPLICATION FIELD... 2. TECHNICAL
More informationElectronic Heat Meters
5 333 WFQ2... WFM2... MEGATRON2 Electronic Heat Meters WFM2... WFQ2... Electronic, mains-independent meters to acquire heating energy consumption in autonomous heating and domestic hot water plants. Storage
More informationThermoPro TM Series TP10
MEASURE TODAY. ENSURE TOMORROW. ThermoPro TM Series TP10 Applications The TP10 thermal energy measurement meter is an ideal choice for a wide range of applications in HVAC, energy production, energy transfer,
More informationIsoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.
www.isomag.eu Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. 1 THE IDEAL FLOWMETERS FOR ANY APPLICATION from DN03 to DN2400 wide range of process
More informationResidential. Ultrasonic Cooling Meter ULTRACOLD T350 (2WR6...) A customer tailored cooling meter designed for residential needs and easy billing
Ultrasonic Cold Cooling Meters Meter Residential Ultrasonic Cooling Meter ULTRACOLD T350 (2WR6...) A customer tailored cooling meter designed for residential needs and easy billing T350 Highest measurement
More informationHeat Meter Integrator
Heat Meter Integrator Features Simply operation Integral wall and DIN-rail mounting bracket Pulsed or M-Bus output options Measures heating or cooling and heat/cooling Specification Product Codes Temperature
More informationWater Metering THE WORLD S MOST ACCURATE COMMERCIAL HYBRID METER
Water Metering THE WORLD S MOST ACCURATE COMMERCIAL HYBRID METER H5000: The World s Most Accurate Commercial Hybrid Meter The H5000 s true hybrid design has the widest measuring range of any water metering
More informationREQUIRED TOOLS 3 mm screw driver Wrench Crosstip screwdriver
MOUNTING AND OPERATING INSTRUCTIONS CF Echo II DELIVERY CF ECHO II Compact heat meter with removable calculator 1 connected fl ow meter 2 temperature sensors (optional) 1 wall mounting bracket 1 package
More informationCompact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:
Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation
More informationTRANSIT TIME FLOW METERS
TRANSIT TIME FLOW METERS TTFM100-F1-NG TTFM100-F2000-NG TTFM100-B-HH-NG TTFM100-F18-NG TTFM200-F3-NG TT100/8812NG RAFALLO PERCALIN CORPORATION Unit 10 MSA Prime Center, Prime St., Madrigal Business Park
More informationInstallation & User Guide. Multical 801. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)
Installation & User Guide Multical 801 (Heating & Cooling) Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Installation and User s Guide MULTICAL 801 www.kamstrup.com USER GUIDE MULTICAL
More informationSentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter
GE Measurement & Control Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas
More informationElectronic Water Meters in measuring cell design
5 343 SIEMECA Electronic Water Meters in measuring cell design WMC... WMH... Electronic, mains-independent meters to acquire water consumption in autonomous domestic water plants. Storage and display of
More informationMagFlux Q 8200 Series
MagFlux Q 8200 Series 3.06 ELECTROMAGNETIC FLOW METER General MagFlux Q Electromagnetic Flow Meter, created in composite materials, designed with an optimized construction which secures optimal performance.
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance
More informationWESAN WP 222. Bulk Water Meter Woltman
APPLICATION The bulk water meter WESAN WP can be used for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. FEATURES 4 For horizontal and vertical installation
More informationVZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side
VZ-01 Oil Counter for Light to Heavy Fuel Oil Description: Features / Mounting on pressure or suction side The VZ-01 series of volume counters are rotary piston meters that function without auxiliary electrical
More informationHeat meter (E1) θ: 2 C C. DK-0200-MI qp, p/l: See display. S/N: /K8/17 Type: 603C219. Pt500-EN Battery, 1 x D-cell
DK-0200-MI004-040 qp, p/l: See display TS 27.02 012 θhc: See display Installation and user s guide MULTICAL 603 Heat meter (E1) Cooling meter (E3) θ: 2 C...180 C θ: 2 C...180 C Θ: 3 K...178 K Θ: 3 K...178
More informationtekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement
Sensing the pulse of industry tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement tekflo sensors are proud to present their tekson TS Series ultrasonic water energy meter, which uniquely
More informationMULTICAL 602 & ULTRAFLOW
Installation and User Guide for MULTICAL 602 & ULTRAFLOW www.kamstrup.com MID designations Permissible operating conditions / measuring ranges: Calculator q: 2 C 180 C DΘ: 3K 170K Temperature sensor pair
More informationHeating Cost Allocation Valve with local acquisition of the flow temperature
2 823 SYNERGYR Heating Cost Allocation Valve with local acquisition of the flow temperature WRV83... Electronic metering and positioning unit. Measures the flow rate and the temperature differential, calculates
More informationTOPAS PMW-basic. Customer benefits. Product features
TOPAS PMW-basic The TOPAS PMW-basic product line covers a wide range of applications in hot water measurement. This innovative system offers all types of water measurement right up to data integration
More informationpremier product range
premier product range PREMIER is a full four quadrant metering platform for use in deregulated markets where data storage, multi utility and AMR facilities are important. PREMIER provides solutions from
More informationDatasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.
Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount
More informationMEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter
MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic
More informationSentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features
Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas flow applications such as: Custody transfer Transmission and distribution Underground storage
More informationNC State University Design and Construction Guidelines Division 23 Energy Management
1.1 Purpose A. The following guidelines provide the methodology and requirements to assure that designs meet NC State standards for campus utility metering. 2.1 General Requirements A. Meters shall have
More informationMULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF
MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF VERSION UF-5xx d INSTALLATION MANUAL ISO 9001:2008 CONTENTS Page INTRODUCTION... 3 1. SAFETY INSTRUCTIONS... 4 2. MOUNTING PREPARATION... 4 3. MOUNTING REQUIREMENTS...
More informationHand held ultrasonic flow meter
Hand held ultrasonic flow meter TDS-100H hand held ultrasonic flow meter is a battery power ultrasonic flow meter,the capability of a full size flow meter. it is carefully designed for portability and
More informationHeat / Chill Meter PolluCom M Installation and Operating Instructions. PolluCom M. Installation and Operating Instructions. M H 1210 INT, Page 1
PolluCom M Installation and Operating Instructions M H 1210 INT, Page 1 The compact meter PolluCom M is suitable for the measurement of energy consumption in heating or chilling plants filled with the
More informationHeating / Cooling Meter PolluCom E Installation and Operation Instructions
Our compact meter PolluCom E is used for measuring energy consumption in plants carrying water as heating or cooling liquid. These installation and operation instructions specify how to install and operate
More informationTemperature sensors. and accessories for heat and cooling measurement points. Applications. Benefits. Features
Temperature sensors and accessories for heat and cooling measurement points Applications Temperature sensors are metrological components for heat or cold measuring points. They are used in pairs and measure
More informationSeries description: Wilo-Stratos
Series description: Wilo-Stratos H/m 16 14 12 1 8 6 4 2 25(3,32,4,5)/1-1 25(3)/1-8 25(3)/1-6 25(3)/1-4 5/1-12 4/1-4 4/1-12 32/1-12 4(5)/1-8 3/1-12 4/1-16 5/1-9 65/1-9 65/1-12 Wilo-Stratos 65/1-16 5/1-16
More informationCONTOIL VZFA/VZOA , versions for higher requirements / applications
CONTOIL VZF/VZO 4...50, versions for higher requirements / applications For applications requiring an increased accuracy of ±0.5 % or better, such as: Measurement of L heating fuel or diesel in testing
More informationThermoPro TM Series TP10
MEASURE TODAY. ENSURE TOMORROW. ThermoPro TM Series TP10 Applications The TP10 thermal energy measurement meter is an ideal choice for a wide range of applications in HVAC, energy production, energy transfer,
More informationCRE A-F-A-E-HQQE 3x HZ
GRUNDFOS DATA BOOKLET CRE64-2-1 A-F-A-E-HQQE 3x4 6 HZ Grundfos pump 96123995 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cre64/96123995/cre-64-2-1-a-f-a-e-hqqe.html
More informationElectronic Water Meters
5 341 Electronic Water Meters WFC... WFH... Electronic, mains-independent meters to acquire water consumption in autonomous domestic water plants. Storage and display of the cumulated consumption values
More informationOPERATING INSTRUCTIONS Flow sensors with connecting flanges DN CE
OPERATING INSTRUCTIONS Flow sensors with connecting flanges DN 40 300 - CE Thank you for choosing our product, for your comfort we present you the operating instructions of flow sensors with connecting
More informationTurbine flowmeters Series TM
Turbine flowmeters Series TM Suitable for liquids Possibility of installation in all flow directions Special design for high pressure available Excellent relationship flow range / flowmeter size Low pressure
More informationULTRASONIC FLOWMETER / HEATMETER
TUF-000F SERIES ULTRASONIC FLOWMETER / HEATMETER www.tuf-000. TUF-000F www. tuf- 000. CONTENTS OVER 0 YEARS' EXPERIENCES SPECIALIZED IN ULTRASONIC FLOW METERS PROFILE 1 Fixed Mounted Inline Type Ultrasonic
More informationzelsius Installation and operating manual All that counts EnergyMetering
EnergyMetering zelsius Installation and operating manual Electronic compact heat meter M-Bus and 2 inputs/outputs optional Coaxial measuring capsule 2" q p 0.6/1.5/2.5 m³/h All that counts General information
More informationMagnetic-inductive flow measurement device Type VOLUMTEC - best performance
Version examples: VOUMTEC in compact version with process connection adapter, welding adapter for pipes according to DIN 11850 and VOUMTEC in separate version without process connection adapter CHARACTERISTICS
More informationElectromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids
Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement
More informationOscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids
Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions
More informationTechnical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis
Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control
More informationAutomated Precision Weighing
Automated Precision Weighing Designed for Automation Compact Precision Weighing High precision Designed to meet the most demanding customer specifications. The WMS is a high speed high accuracy weigh module
More informationCirculator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control
Type series booklet 1115.52/2-10 Riotec r /Riotec r Z Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control Riotec Riotec Z Energy efficiency class
More informationaquaconcept Product features Customer benefits
aquaconcept The unique aquaconcept modular design covers a wide range of water applications. This innovative system offers all types of water measurement right up to data integration into your specific
More informationElectronic Water Meters
5 328 SIEMECA Electronic Water Meters WFC WFH Electronic, mains-independent meters to acquire water consumption in autonomous domestic water plants. Storage and display of the cumulated consumption values
More informationLower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).
PRODUCT APPLICATIONS / APPLICATION QUALIFICATION DIMENSIONAL SPECIFICATIONS MECHANICAL DIMENSIONS: INCHES (mm) DOPPLER ULTRASONIC FLOW METER Carbonated liquids Mining slurry Drilling mud Coal-seam water
More informationFood & beverage. Oil & gas. Water & waste water
Overview MSS 2100 MC1 DN 50 to DN 150 (2 to 6 ) are suitable for accurate mass flow measurement for all kind of liquids and gases. The sensor offers superior performance in terms of flow accuracy, turn-down
More information