ASTM D4. Bitumen Content Qty. Model Description. Related Standards: ASTM D370, E177

Similar documents
ASTM D4. Bitumen Content Qty. Model Description. Related Standards: ASTM D370, E177

Geotechnical Testing Equipment

DMS-9202, Asphaltic Concrete Patching Material (Stockpile Storage)

DMS-9203, Asphaltic Concrete Patching Material (Containerized)

Section 4 DMS-9203, Asphaltic Concrete Patching Material (Containerized)

A SURVEY OF OUR KNOW-HOW : PETROLEUM GLASSWARE VISCOMETER TUBES

DMS ASPHALTIC CONCRETE PATCHING MATERIAL (STOCKPILE STORAGE)

Special Provision No. 111S12 July 2017

SECTION 118 ASPHALT MATERIAL

Penetration. Test Methods

Softening point by Ring & Ball. Density and relative density of liquids by Hubbart pycnometer

DRAFT Jamaican Standard Specification for Bituminous materials

SECTION 916 (Pages ) is deleted and the following substituted: SECTION 916 BITUMINOUS MATERIALS

DMS-9202 Asphaltic Concrete Patching Material (Stockpile Storage or Bagged)

MATERIAL SPECIFICATION FOR EMULSIFIED ASPHALT

MATERIAL SPECIFICATION FOR EMULSIFIED ASPHALT

Products for Asphalt Testing

product manual H-1240 & H F Electric Penetrometer with Digital Automatic Timer

Laboratory Certification For. Shakib Dastaggir Construction & Design Company (S-CAD) Laboratory

Tex-614-J, Testing Epoxy Materials

MATERIAL SPECIFICATION FOR EMULSIFIED ASPHALT

Superpave Asphalt Binders

Tex-614-J, Testing Epoxy Materials

Background. Asphalt Soluble in petroleum products. Tar Resistant to petroleum products Generally by-product of coke (from coal) production

Index for Labs under Civil Engineering

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CEMENT TEST EQUIPMENTS

U tube viscometer. Kinematic viscosity bath RASAYAN

Laboratory Equipment. Tel: +44 (0) u Fax: +44 (0) u

SECTION B ASPHALT BITUMEN PAVETEST

Geoscience Testing laboratory (Al Ain)

Heritage Research Group 940 N. Wynn Rd - Oregon, OH Phone (419) Fax (317)

( Group D ) Detailed Tender Notice No. DTE/PUR/14/ 328 Dated Civil Engineering Department. Kulgam. Anantnag

HA Thickness Gauge IS:2386 (part 1)- 1963

Oregon Department of Transportation Standard Specifications For Asphalt Materials 2004

Scientific glass blowing

TESIGNG OF FUELS: VISCOSITY OF LIQUID FUELS

EQUIPMENT AVAILABLE FOR KWRP SITE AS ON Sl.No

LABORATORY EQUIPMENT FOR CENTRAL MATERIALS LABORATORY AND UPCOUNTRY LABORATORIES FOR FY 2018/2019

- New Superpave Performance Graded Specification. Asphalt Cements

Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka

NEAT ASPHALTS 40-50, 60-70, , , , & Complies to ASTM D 946 & AASHTO M20, BS 3670 DIN 1995

General Apparatus. Petroleum Products Timers Clamps Frames Laboratory Jacks Set-up Frame Set.

SULFUR EXTENDED ASPHALT INVESTIGATION - LABORATORY AND FIELD TRIAL

For the fastest possible service, you can now reach Koehler via the Internet. On our website, you can:

MATERIAL SPECIFICATION FOR LIQUID ASPHALT USED IN SPRAYING, SEALING, AND PRIMING APPLICATIONS

Precision Thermometers for Material Testing

Section B BITUMEN - ASPHALT. section B BITUMEN - ASPHALT

Petroleum Testing Equipment

PETROLEUM TESTING EQUIPMENT N-WISSEN 2016

Section 5 Specification 5.7 Supply of Asphalt TABLE OF CONTENTS

ASTM THERMOMETERS, TEST SPECIMENS AND GLASSWARE

Crude Oil and E&P Testing Laboratory Instruments for quality control, analysis and calibration

Characterization of crude:

Petroleum Test Instruments Product Range

MATERIAL SPECIFICATION FOR LIQUID ASPHALT USED IN SPRAYING, SEALING, AND PRIMING APPLICATIONS

Stabinger Viscometer SVM 3001

Standard Test Method for Dropping Point of Lubricating Grease 1


ASTM-API Thermometers

L U B R I C A N T S & MATERIALS

POLYLAB Price List September

Competence in Plastic Labware

Vessels and Distillation Equipment

Supply of Services for Detailed OEB Crude Assay Analysis

TEST FACILITIES AT SQAE(GS), KOLKATA LAB STORES DTE Name of Estt with address, Name of Srl.No Nodal officer and contact No

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

Viscosity & Flash Point Standards For Reference, Validation, and Calibration

Certificate of Accreditation

ISO 3679 INTERNATIONAL STANDARD. Determination of flash point Rapid equilibrium closed cup method

DEPARTMENT OF CHEMICAL ENGINEERING University of Engineering & Technology, Lahore. Energy Engineering Lab

The Safest Heating Method!

USES FOR RECYCLED OIL

Viscosity & Flash Point Standards For Reference, Validation, and Calibration

DEPARTMENT OF CIVIL ENGINEERING SCHOOL OF ENGINEERING GAUTAM BUDDHA UNIVERSITY

Paragon Scientific Ltd Proficiency Testing Scheme Schedule

BILLING RATES - FY 18/19

BILLING RATES - FY 17/18

ISO 659 INTERNATIONAL STANDARD. Oilseeds Determination of oil content (Reference method)

Hari Shankar Singhania Elastomer & Tyre Research Institute, HASETRI, Plot No. 437, R&D Center, Hebbal Industrial Area, Mysuru, Karnataka

Manufacturer since


Foaming of Lubricating Oils (manual)

Manual Kinematic Viscosity Bath Tamson TV12

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles.

Faculty of Mechanical Engineering B.E. Automobile Engineering (R 2013) Semester III

Date and Time of Pre Bid Meeting November 22, 2016 at a.m

Tests conducted under the following industry standards for PermaFrost API ASHRAE ARI ASTM EPA ANSI UL. SINCE 1985 Quality Controlled Through Analysis

Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) 1

Lubricant Testing Solutions Laboratory Instruments for quality control, analysis and calibration

Rick Marinelli. Manager, Airport Engineering Division, AAS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

LUBRICATING GREASES. Test Methods

Memorandum. From: Date: Arports Regional Division Managers

एमआरप एल ग णव नय ण य गश ल उप दन व श:२०१७ MRPL QC LABORATORY

Production of Biodiesel from Used Groundnut Oil from Bosso Market, Minna, Niger State, Nigeria

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010. ASTM INTERNATIONAL 100 Barr Harbor Drive West Conshohocken, PA Amy Meacock

Bitumen and Petroleum Testing Equipment

Item Code Description Pack Size Unit Stock on Hand. LBS Filter paper Qualitative 240mm 100pcs EA

Transcription:

ASTM D4 Related Standards: ASTM D370, E77 Bitumen Content H-550 Bitumen soluble in organic solvents set H-550. Gooch crucible H-550.2 Crucible holder H-550.3 Buchner funnel H-550.8 Glass fiber filter H-255 Adapter, 3/8" threaded H-493.500 Flask, vented, 500 ml H-550.5 Stopper #7 Note: Also required but not part of basic set Drying oven, Bunsen burner or muffle furnace, analytical balance, suction pump, desiccator, evaporating dish and watch glasses. 2

ASTM D5 Related Standards: ASTM C670, D36, D244, E, E77, E37, E225; ANSI Standard: B46.); ISO Standard: 468 Penetration of Bituminous Materials H-200 H-240 H-250 Universal penetrometer (includes standard needle) Electric penetrometer (includes auto timer & standard needle) Portable penetrometer (includes standard needle) H-352 Transfer dish H-350.3 Sample Box w/lid, Tin 3028 (36 box) choose from: H-260.7C H-2600.7F H-260.63C H-2600.63F H-260.64C H-2600.64F ASTM Thermometer Note: Also required but not part of basic set Water bath; timing device on hand-operated models. For 220V-50/60Hz applications, substitute: H-240.4F Electric penetrometer with digital timer, 220V 50/60 Hz 3

Related Standards: ASTM C670, D92, D40, D346, E) ASTM D36 Softening Point of Bitumen (Ring-and-Ball Apparatus) H-569 H-570 Two ring assembly Four ring assembly choose from: H-2600.5F H-260.C H-2600.6F H-260.6C H-2600.3F H-260.3C ASTM Thermometer H-595 H-596 Single Softening Point Apparatus Set Single Softening Point Apparatus Set, Hot plate version For 220V-50/60Hz applications, substitute: H-596 with H-596.4F Single Softening Point Apparatus Set, Hot plate version, 220V 50/60 Hz 4

ASTM D70 Related Standards: ASTM C670, D40, D342, D3289, D43, E Density of Semi-Solid Bituminous Materials (Pycnometer Method) H-2640 H-2660 Hubbard 24ml specific gravity bottle Hubbard-Carmick 24ml specific gravity bottle H-260.63C Thermometer: -89 to 32 C H-49.600 Low form Griffin 600 ml glass beaker Note: Also required but not part of basic set Water bath capable of. C and Balance to.00g 5

ASTM D88 Related Standards: ASTM D93, D7, D40, D244, D445, D26, D270, D4057, D477, E, E, E02 Saybolt Viscosity H-265 Saybolt viscometer bath 2-4 2-4 H-27 H-272 H-273 H-274 Stainless steel viscometer tubes Brass viscometer tubes Stainless steel universal orifices Stainless steel Furol orifices H-275 Tube cleaner 0 2-4 H-276 Saybolt receiving flask, graduated 60ml H-2600.7F H-260.7C H-2600.8F H-260.8C H-2600.9F H-260.9C H-2600.20F H-260.20C H-2600.2F H-260.2C H-2600.22F H-260.22C Saybolt viscosity thermometer Saybolt viscosity thermometer Saybolt viscosity thermometer Saybolt viscosity thermometer Saybolt viscosity thermometer Saybolt viscosity thermometer Saybolt viscosity thermometer Saybolt viscosity thermometer Saybolt viscosity thermometer Saybolt viscosity thermometer Saybolt viscosity thermometer Saybolt viscosity thermometer Note: Also required but not part of basic set distilled water, or Mineral oil H-289, or Silicon oil H-299 (high temp) and Optional Thermometer support H-295 For 220V-50/60Hz applications, substitute: H-265 with H-265.4F Saybolt viscometer bath, 220V 50/60Hz23 6

ASTM D92 Related Standards: ASTM D93, D40, D30, D4057, D477, D4206, E, E300) (Related IP Standard: Specification for IP Standard Thermometers) (Related ISO Standards: Guide 34, Guide 35 Flash and Fire Points by Cleveland Open Cup Tester H-2085 Electric Cleveland open cup flash tester. (Includes heating plate, flash cup, and thermometer) H-2095 Natural Gas Cleveland flash and fire point tester H-200 Gas Cleveland flash and fire point tester Note: Also required but not part of basic sets Cleaning solvents, e.g., acetone or toluene For 220V 50/60Hz applications, substitute: H-2085 with H-2085.4F Electric Cleveland open cup flash tester, 220V 50/60Hz (Includes heating plate, flash cup, and thermometer). 7

ASTM D95 Related Standards: D244, D796, D4006, D4057, D477, D5854, E23) (Related API Standards: MPMS Chapters 8., 8.2, 8.3, 0.2, 0.6) Water in Petroleum Products and Bituminous Materials by Distillation H-2430 Dean-Stark electric apparatus for water in petroleum products H-2440 Dean-Stark gas-heated water in petroleum products apparatus H-2348 Still Cleaner Note: Also required but not part of basic set Solvent-carrier liquid depending on material being tested. For 230V applications, substitute: H-2430 with H-2430.5F Dean-Stark electric apparatus for water in petroleum products, 230V-50Hz 8

ASTM D97 Related Standards: ASTM D7, D396, D659, D2500, D3245, E, E77) (Related IP Standards: Specifications for IP Standard Thermometers) Pour Point of Petroleum Products H-2560 Cloud and Pour Point Apparatus Set H-2600.5F H-260.5C H-2600.6F H-260.6C ASTM E Thermometer -36 to 20 F ASTM E Thermometer -38 to 50 C ASTM E Thermometer -2 to 70 F ASTM E Thermometer -80 to 20 C Note: Also required but not part of basic set Low temperature bath solvents and melting point thermometer. 9

ASTM D3 Related Standards: ASTM D670, D5, D754, D2872, D6084, E, E. Ductility of Bituminous Materials H-050 H-068B H-260.63C ASTM Thermometer Ductility Testing Machine, 3-Speed. Ductility Testing Machine, 3-Speed w/temperature-control circulator for standard and forced tests. Note: Also recommended but not part of basic set H-068PC plastic cover for constant temperature control For 220V applications, substitute: H-050 with H-050.2F, 220V-60Hz or H-050.5F, 220V-50Hz Ductility Testing Machine, 3-Speed. or H-068B with H-068B.2F, 220V-60Hz or H-068B.5F, 220V-50Hz Ductility Testing Machine, 3-Speed w/temperature-control circulator for standard and forced tests. or, use: H-060A.2F, 220V-60Hz or H-060A.5F, 220V-50Hz Ductility Testing Machine, Refrigerated 0

ASTM D5 Related Standards: Many depending on property measured Testing Solvent Containing Varnishes Used for Electrical Insulation H-2640 Specific gravity bottle, 24 ml Note: Also required but not part of basic set numerous items specific to the test(s) being conducted.

ASTM D7 Related Standards: Many Guide for Sampling, Test Methods, and Specifications for Electrical Insulating Oils of Petroleum Origin H-2405B H-2405S Bacon Bomb sampler, 8-oz., brass Bacon Bomb sampler, 8-oz, stainless steel H-2560 Cloud and Pour Point apparatus set H-2085 H-2095 Electric Cleveland Flash and Fire Point tester Natural Gas Cleveland Flash and Fire Point tester Note: The above products represent only a small portion of items required. Please refer to the ASTM standard for a complete listing of the testing equipment required to carry out all test procedures used in the standard. For 220V applications, substitute: H-2085 with H-2085.4F, 220V-50/60Hz Electric Cleveland Flash and Fire Point tester 2

ASTM D39 Related Standards: ASTM C670, D40, D244, D270, E (Related IEC Standards: 60854) Float Test for Bituminous Materials H-400 Asphalt Viscosimeter Float Test Set H-2600.5F H-260.5C Low Softening Point thermometer Low Softening Point thermometer Note: Also required but not part of basic set Testing bath, water bath, thermocouple thermometer and brass pouring plate. 3

ASTM D89 Related Standards: ASTM D482, D524, D4046, D4057, D475, D477, D4530, E, E33 Conradson Carbon Residue of Petroleum Products H-2495 Conradson carbon residue apparatus Note: Also required but not part of basic set Weighing balance and timer 4

ASTM D27 Related Standards: ASTM CD937, D403 Cone Penetration of Lubricating Grease H-250 H-200 H-2520 H-2522 Grease Penetrometer Universal Penetrometer Hollow Brass Cone Hollow Stainless Steel Cone H-2535 Lever-operated grease worker H-2540 Grease cutter H-263D Dial thermometer H-240 Electric Penetrometer H-250 Portable Penetrometer Note: Also required but not part of basic sets Air or water bath at 25 +/-.5 C, and spatula. For 220V applications, substitute: H-240 with H-240.4F Electric Penetrometer, 220V-50/60Hz 5

Methods and Practices for Emulsified Asphalts ASTM D244 Related Standards: Many since the method covers tests for composition, consistency, stability and examination of residue. H-2430 Triple Beam Balance, 260g x 0.g Cap. with H-4609 Weight set H-2440 Pycnometer Top and Jar H-2450 Conical Mold and Tamper H-2600.9F H-260.9C ASTM thermometer ASTM thermometer H-2444 Stirring Rod, glass H-2452 Two particle charge meter plates H-495.250 Beaker, 250ml H-2285 Emulsified Asphalts Distillation Apparatus H-2290 Emulsified Asphalt Water Content Distillation Apparatus HB-40 Balance: 4,00g x.g H-265 Saybolt Viscometer Bath H-2600.7F H-260.7C H-2600.9F H-260.9C ASTM thermometer ASTM thermometer ASTM thermometer ASTM thermometer * Order H-273 if a weighing bench & top platform and low-cost scale H-4537WB is preferred. Note: Also required but not part of basic sets No. 20 sieve, vacuum pump, freezer, water bath and labware. For 220V applications, substitute: H-2430 with H-2430.4F Dean-Stark Electric Apparatus for Water in Petroleum Products, 220V, 50/60Hz H-265 with H-265.4F Saybolt Viscometer Bath, 220V, 50/60Hz H-2450 with H-2450.4F Particle Charge Meter, 220V, 50/60Hz 6

ASTM D270 Standard has been withdrawn Methods of Sampling 7

Related Standards: Many in list of test methods in this standard ASTM D333 Guide for Clear and Pigmented Lacquers H-530. No. Orifice for Ford Viscosity Cup H-530.2 No.2 Orifice for Ford Viscosity Cup H-530.3 No.3 Orifice for Ford Viscosity Cup H-530.4 No.4 Orifice for Ford Viscosity Cup H-530.5 No.5 Orifice for Ford Viscosity Cup H-2600.7F H-260.7C ASTM thermometer ASTM thermometer H-535 Viscosity cup stand HP-08 Stainless Steel Weight-per-gallon Cup Note: The above products represent only a small portion of items required. Please refer to the ASTM standard for a complete listing of the testing equipment required to carry out all test procedures used in the standard. 8

ASTM D365 Related Standards: Many depending on the test(s) being performed Guide for Nitrocellulose Based Solutions H-530. No. Orifice for Ford Viscosity Cup H-530.2 No.2 Orifice for Ford Viscosity Cup H-530.3 No.3 Orifice for Ford Viscosity Cup H-530.4 No.4 Orifice for Ford Viscosity Cup H-530.5 No.5 Orifice for Ford Viscosity Cup H-2600.7F H-260.7C ASTM thermometer ASTM thermometer H-535 Viscosity cup stand HP-08 Stainless Steel Weight-per-gallon Cup Note: The above products represent only a small portion of items required. Please refer to the ASTM standard for a complete listing of the testing equipment required to carry out all test procedures used in the standard. 9

ASTM D402 Related Standards: ASTM D86, D370, E, E33, E220; Related IP Standards: IP 2); Related British Standards: 658:989, & C.O.3 Distillation of Cut-Back Asphaltic (Bituminous) Products H-90 Distillation of cut-back asphaltic (bituminous) products Note: Also required but not part of basic set Balance or Scale and a 500ml flask. 20

ASTM D445 Related Standards: ASTM D446, D93, D27, D480, D48, D262, D270, D27, D6074, D667, E, E77); Related ISO Standards: 304, 305, 3696, 5725, 9000, 7025; Related NIST Standards: Tech Note 297, GMP, Special Pub. 89 Kinematic Viscosity of Transparent and Opaque Liquids (and the Calculation of Dynamic Viscosity) H-720 Constant Temperature Bath (Cannon Model CT-500) H-745 Vacuum manifold H-732 UBF Bath oil for use below 2 C H-730 Constant Temperature Bath (Cannon Model CT-000) H-735 Vacuum manifold H-733 High-temperature bath silicone for use above 35 C Note: Also required but not part of basic sets Glass capillary viscometer(s) depending on range & precision thermometer(s).. For 240V applications, substitute: H-720 with H-720.4F Constant Temperature Bath (Cannon Model CT-500), 240V 50-60Hz H-730 with H-730.4F Constant Temperature Bath (Cannon Model CT-000), 240V 50-60Hz 2

Related Standards: ASTM D27. ASTM D937 Cone Penetration of Petrolatum H-200 H-240 H-250 H-2520 H-2522 Universal penetrometer (includes standard needle) Electric penetrometer (includes auto timer & standard needle) Portable penetrometer (includes standard needle) Grease penetration cone, brass cone Grease penetration cone, stainless steel cone Note: Also required but not part of basic set Oven, water bath, sample containers and thermometer. For 220V applications, substitute: H-240 with H-240.4F Penetrometer with digital timer, 220V, 50/60Hz 22

ASTM D968 Related Standards: D823, D005, D86, D400, E; Related ANSI Standard: B74.2; Other related Standard: 42-GB-984-R993 FEPA Abrasion Resistance of Organic Coatings by Falling Abrasive HP-60 Falling Sand Abrasion Tester H-3820 Ottawa silica sand (applies to Method A) 23

ASTM D68 Related Standards: Hydrocarbon Waxes Used for Electrical Insulation H-200 H-240 H-250 Universal penetrometer (includes standard needle) Electric penetrometer (includes auto timer & standard needle) Portable penetrometer (includes standard needle) H-30 H-37 Hardened, stainless steel wax penetration needle Certified, to ASTM accuracy, Hardened, stainless steel wax penetration needle Note: Also required but not part of basic sets Spatula & thermometer. For 220V applications, substitute: H-240 with H-240.4F Penetrometer with digital timer, 220V, 50/60Hz 24

ASTM D9 Related Standards: Standard has been withdrawn and replaced by ASTM D5329 Concrete Joint Sealers 25

ASTM D200 Related Standards: ASTM E Viscosity by Ford Viscosity Cup H-530. No. Orifice for Ford Viscosity Cup H-530.2 No.2 Orifice for Ford Viscosity Cup H-530.3 No.3 Orifice for Ford Viscosity Cup H-530.4 No.4 Orifice for Ford Viscosity Cup H-530.5 No.5 Orifice for Ford Viscosity Cup H-2600.7F H-260.7C ASTM thermometer ASTM thermometer H-535 Viscosity cup stand HP-08 Stainless Steel Weight-per-gallon Cup Note: Also required but not part of basic set Timing device. 26

ASTM D30 Related Standards: ASTM D92, D343 Flash Point and Fire Point of Liquids by Tag Open Cup Apparatus H-990 Tag open-cup flash tester H-990.2 Leveling device H-990.3 Draft shield H-2600.9F H-260.9C ASTM thermometer ASTM thermometer H-995 Tag open-cup burner with gas burner Note: Also recommended but not part of basic sets Replacement Pyrex cup H-990. For 230V applications, substitute: H-990 with H-990.4F Tag open-cup flash tester, 230V, 50/60Hz 27

Related Standards: ASTM D8, D87, D27, D937, D938, E) ASTM D32 Needle Penetration of Petroleum Waxes H-200 H-240 H-250 Universal penetrometer (includes standard needle) Electric penetrometer (includes auto timer & standard needle) Portable penetrometer (includes standard needle) H-30 H-37 H-2600.64F H-260.64C Hardened, stainless steel wax penetration needle Certified, to ASTM accuracy, Hardened, stainless steel wax penetration needle ASTM Thermometer ASTM Thermometer Note: Also required but not part of basic set Brass cylinder mold & plate, water bath and test room. Timing Device is needed if Penetrometer chosen does not include built-in timer, H-226 recommended. For 220V applications, substitute: H-240 with H-240.4F Penetrometer with digital timer, 220V, 50/60Hz 28

ASTM D395 ASTM standard withdrawn, no replacement Abrasion Resistance of Clear Floor Coatings 29

Related Standards: D27, D475; IP Standard: IP 50 ASTM D403 Cone Penetration of Lubricating Grease Using One-Quarter and One-Half Scale Cone Equipment H-200 H-240 H-250 Universal penetrometer (includes standard needle) Electric penetrometer (includes auto timer & standard needle) Portable penetrometer (includes standard needle) H-259 Penetration cone for grease H-255 Micro Grease H-4907 Spatula For 220V applications, substitute: H-240 with H-240.4F Penetrometer with digital timer, 220V, 50/60Hz 30

ASTM D46 Related Standards: ASTM D244, D979 Moisture or Volatile Distillates in Bituminous Paving Mixtures H-2442.0 Distillation Apparatus for Moisture in Bituminous Paving Mixtures H-2348 Still Cleaner H-2442.25 Distillation Apparatus for Volatiles in Bituminous Paving Mixtures Note: Also required but not part of basic set Various aromatic solvents.. 3

ASTM D559 ASTM standard withdrawn, no replacement Related Standards: ASTM D6927 Resistance to Plastic Flow of Bituminous Mixtures Using Marshall Apparatus 32

ASTM D83 Related Standards: ASTM D27, D403, D475) Roll Stability of Lubricating Grease H-200 H-240 H-250 Universal penetrometer (includes standard needle) Electric penetrometer (includes auto timer & standard needle) Portable penetrometer (includes standard needle) H-259 Penetration cone for grease H-255 Micro Grease H-4907 Spatula Note: Also required but not part of basic set Roll stability tester and constant temperature bath or room. For 220V applications, substitute: H-240 with H-240.4F Penetrometer with digital timer, 220V, 50/60Hz 33

ASTM standard withdrawn, Replaced by: ASTM D5329 Jet Fuel Resistant Concrete Joint Sealer, Hot Poured Elastic Type ASTM D855 34

ASTM D856 Related Standards: ASTM C670, D96, D272, D2939, E Recovery of Asphalt From Solution by Abson Method H-857 Filterless centrifuge extractor H-2600.7F H-260.7C ASTM Thermometer ASTM Thermometer Note: Also required but not part of basic sets Carbon dioxide gas and reagent grade trichloroethylene. For 230V applications, substitute: H-857 with H-857.2F, 230V 60Hz or H-857.5F Vibrating Table, 230V 50Hz 35

ASTM standard withdrawn, no replacement Specific Gravity of Drying Oils, Varnishes, Resins and Related Material at 25/250 C ASTM D963 36

ASTM D204 Related Standards: ASTM C670, D979, D4753, E, E2; AASHTO T209, T283 for 6000g samples Theoretical Maximum Specific Gravity and Density of Bituminous Paving Mixtures H-750 H-750SS H-782 H-756A.3F Vacuum Pycnometer, aluminum, (Rice Test) Set Vacuum Pycnometer, stainless steel, (Rice Test) Set Orbital de-airing table Vibrating Apparatus for Pycnometer H-754D Digital Manometer H-749 Vacuum slow release valve H-763A High vacuum pump 5V,60Hz H-759 Indicating Drierite air drying unit Note: Also required but not part of basic sets Water bath, thermometers, drying oven and weighing balance. For 220V applications, substitute: H-782 with H-782.4F, 220V 50/60Hz H-763A with H-763A.4F, 220V 50/60H H-754D with H-750D.4F AASHTO 6000g Samples H-820 Vacuum Pycnometer, Large Capacity, (Rice Test) Set H-826A Vibrating Apparatus for Pycnometer, Large Capacity, H-754D Digital Manometer H-749 Vacuum slow release valve H-763A High vacuum pump 5V,60Hz H-759 Indicating Drierite air drying unit Note: Also required but not part of basic sets Water bath, thermometers, drying oven and weighing balance. For 220V applications, substitute: H-826 with H-826.4F, 220V 50/60Hz H-763A with H-763A.4F, 220V 50/60Hz H-754D with H-750D.4F 37

ASTM D2042 Related Standards: ASTM D4, D238, D2764, E77); AASHTO Standard: T44 Solubility of Asphalt Materials in Trichloroethylene H-550 Bitumen soluble in organic solvents set H-3005 Bench oven, forced air 5V 60Hz Note: Also required but not part of basic set Technical grade trichloroethylene. For 230V applications, substitute: H-3005 with H-3005.4F Bench oven, forced air, 220V 50/60Hz 38

ASTM D270 Related Standards: ASTM C670, D92, D34, D445, D446, D262, D2493, E, E77; Related IP Standard: 39/84 Kinematic Viscosity of Asphalts (Bitumens) H-746. through.0 Zeitfuchs Cross-Arm Viscometer and Holder H-2600.47F H-260.47C H-2600.0F H-260.0C ASTM Thermometer ASTM Thermometer ASTM Thermometer ASTM Thermometer Note: Entire series covers the range from.6 to 00,000 Centistokes Also required but not part of basic set Constant temperature bath (see D445) and timer. 39

ASTM D27 Viscosity of Asphalts by Vacuum Capillary Viscometer H-746. through.5 Zeitfuchs Cross-Arm Viscometer and Holder H-2600.47F H-260.47C H-74 Series ASTM Thermometer ASTM Thermometer Digital Vacuum Pressure Regulator Note: Entire series covers the range from 42 to 200,000 Poise. Also required, but not part of the basic set Constant temperature bath (see D445). a vacuum pump or aspirator and timer. 40

ASTM D272 Related Standards: ASTM C7, C28, C36, C670, D70, D604, D979, D46, D856, D2, D6368; Federal Spec.: O-T-634 Quantitative Extraction of Bitumen from Bituminous Paving Mixtures Test Method A H-45 H-452 H-456 H-460 H-46 H-466 H-464 H-465 H-47 H-473 H-474 500g Centrifuge Extractor, analog, 5V 60Hz 500g Centrifuge Extractor, analog, 5V 60Hz 500g Centrifuge Extractor, analog, 5V 60Hz 500g Centrifuge Extractor, digital, 5V 60Hz 500g Centrifuge Extractor, digital, 5V 60Hz 500g Centrifuge Extractor, analog, 5V 60Hz 3000g Centrifuge Extractor, digital, 5V 60Hz 3000g Centrifuge Extractor, digital, 5V 60Hz 3000g Centrifuge Extractor, analog, 5V 60Hz 3000g Centrifuge Extractor, analog, 5V 60Hz 3000g Centrifuge Extractor, analog, 5V 60Hz H-495 series Graduated cylinder H-4962 Desiccab Desiccator H-3005 Bench oven, forced air 5V 60Hz choose H-487.627 H-489.627 H-48.627 Replacement filter rings (00) Replacement filter rings (00) Replacement filter rings (00) Note: Also required but not part of basic sets Weighing balance, flat pan, reagent grade solvents, and vacuum source. For 220/230V applications, substitute: H-45 with H-45.4F 500g Centrifuge Extractor, analog, 220V 50/60Hz H-452 with H-452.4F 500g Centrifuge Extractor, analog, 220V 50/60Hz H-456 with H-456.4F 500g Centrifuge Extractor, analog, 220V 50/60Hz H-460 with H-460.4F 500g Centrifuge Extractor, digital, 220V 50/60Hz H-46 with H-46.4F 500g Centrifuge Extractor, digital, 220V 50/60Hz H-466 with H-466.4F 500g Centrifuge Extractor, analog, 220V 50/60Hz H-464 with H-464.4F 3000g Centrifuge Extractor, digital, 220V 50/60Hz H-465 with H-465.4F 3000g Centrifuge Extractor, digital, 220V 50/60Hz H-47 with H-47.4F 3000g Centrifuge Extractor, analog, 220V 50/60Hz H-473 with H-473.4F 3000g Centrifuge Extractor, analog, 220V 50/60Hz H-474 with H-474.4F 3000g Centrifuge Extractor, analog, 220V 50/60Hz H-3005 with H-3005.4F Bench oven, forced air 230V 50/60Hz 4

ASTM D272 Related Standards: ASTM C7, C28, C36, C670, D70, D604, D979, D46, D856, D2, D6368; Federal Spec.: O-T-634 Quantitative Extraction of Bitumen from Bituminous Paving Mixtures Test Method B H-495 H-499 000g Reflux extractor set, 5V 60Hz 2000g Reflux extractor set, 5V 60Hz H-495 series Graduated cylinder H-4962 Desiccab Desiccator H-3005 Bench oven, forced air 5V 60Hz choose H-497.63 H-498.63 Filter Paper, 33cm, (00) Filter Paper, 40cm, (00) Note: Also required but not part of basic sets Weighing balance, flat pan, reagent grade solvents, and vacuum source. For 220/230V applications, substitute: H-495 with H-495.4F 000g Reflux extractor set, 220V 50/60Hz H-499 with H-499.4F 2000g Reflux extractor set, 220V 50/60Hz H-3005 with H-3005.4F Bench oven, forced air 230V 50/60Hz 42

ASTM D246 Related Standards: ASTM D40, D89, D370, D245, E Coking Value of Tar and Pitch (Modified Conradson) H-2494 Porcelain crucible H-2497 Skidmore crucible and cover H-2496 Carbon residue apparatus hood H-2498 Nickel crucible with cover H-2505 Refractory block insulator ring H-3920FS30 Sieve, U.S. Standard No. 30 Note: Also required but not part of basic set Vertical electric furnace and pyrometer controller. 43

ASTM D2500 Related Standards: ASTM D500, E; Energy Institute Standard: Spec for IP Standard Thermometers Cloud Point of Petroleum Products H-2560 Cloud and Pour Point Apparatus Set H-2600.5F H-260.5C H-2600.6F H-260.6C ASTM E Thermometer, -35 to 20 F ASTM E Thermometer, -38 to 50 C ASTM E Thermometer, -2 to 70 F ASTM E Thermometer, -80 to 20 C Note: Also required but not part of basic set Low temperature bath and technical grade solvents. 44

ASTM D2872 Related Standards: ASTM D3, D27, E, E644, E37 Effect of Heat and Air on a Moving Film of Asphalt (Rolling Thin-Film Oven Test) H-30068.2F H-30068.5F Asphalt rolling thin film oven, 208-230V, 60Hz Asphalt rolling thin film over, 220V 50Hz H-260.3C ASTM E Thermometer, 55 to 70C Note: Also required but not part of basic set A stainless steel or aluminum cooling rack. 45

ASTM D343 Related Standards: ASTM D92, D30, E; Related IP Standard: IP 36 Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus H-995 Tag open-cup flash tester with gas burner H-990.2 Leveling device H-990.3 Draft shield H-260.9F H-260.9C ASTM E Thermometer, 20 to 230 F ASTM E Thermometer, -5 to 0 C Note: Also recommended but not part of basic set Replacement Pyrex cup, H-990.. 46

ASTM D423 ASTM standard withdrawn, no replacement, Related Standards: ASTM D4867 Indirect Tension Test for Resilient Modulus of Bituminous Mixtures 47

Related Standards: Many - for preparing and testing specimens ASTM D4867 Effect of Moisture on Asphalt Concrete Paving Mixtures H-750 Vacuum Pycnometer Set, Aluminum, 2kg Capacity H-756.3F Vibrating Table, Variable-Speed for H-750 Pycnometer, 0/220V 50/60Hz H-763A Vacuum Pump with Gauge, High, 5V 60Hz H-754D Manometer, Digital with AC Adapter, 0V 60Hz HM-327TSR TSR Loader, Automatic, Digital Display, 0V /60Hz Note: Also required but not part of basic set: Oven with temperature specification 230 +/- 0 F (0+/- 5 C), Water bath 77+/-2 F (25 +/- C) and thermometer to F (0.5 C). For 220V applications, substitute: H-763A with H-763A.4F Vacuum Pump with Gauge, High, 220V 50/60Hz H-754D with H-754D.4F Manometer, Digital with AC Adapter, 220V 50/60Hz HM-327TSR with HM-327TSR.5F TSR Loader, Automatic, Digital Display, 230V 50/60Hz 48

ASTM D5329 Related Standards: Many standards use these test methods, refer to the material specification of interest Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphaltic and Portland Cement Concrete Pavements H-200 H-240 H-250 Universal penetrometer (includes standard needle) Electric penetrometer (includes auto timer & standard needle) Portable penetrometer (includes standard needle) H-320 Resilience ball penetration tool H-790 Joint Bond tester Note: Also required but not part of basic set Items depend on the several tests that may be performed. For 220V applications, substitute: H-240 with H-240.4F Electric penetrometer with digital time, 220V, 50/60Hz 49

ASTM D558 Related Standards: ASTM C670, D559, E Resistance to Plastic Flow of Bituminous Mixtures Using Marshall Apparatus (6 inch-diameter Specimen) 9 H-367 Compaction mold for 6 Marshall samples H-363 Mold extractor, 6 inch H-394 Constant Temperature Water Bath, 0V 60Hz H-353A Hand-operated sample ejector H-366 Heavy-duty automatic single compactor H-362 Breaking head, 6" HM327MAR Marshall/TSR Loader with Load Cell, Strain Transducer and HMTS Marshall Module Software, 5V 60Hz H-384 Mixer, 5 Qt. ASTM-compliant H-4952 Heavy-duty hotplate Note: Also required but not part of basic sets Weighing balance, thermometers, various containers and labware. For 220V applications, substitute: H-394 with H-394.4F Constant Temperature Water Bath, 220V-50/60Hz. H-366 with H-366.4F Heavy-duty automatic single compactor, 220V-50/60Hz. H-384 with H-384.5F MIxer, 5Qt. ASTM-Compliant, 220V-50Hz. 50

ASTM D5892 Related Standards: ASTM D5, D36, D92, D3, D40, D754, D270, D2872, D4957, D5546, D6084, E) Type IV Polymer-Modified Asphalt Cement for Use in Pavement Construction 5

ASTM D6084 Related Standards: ASTM C670, D5, D3, E, E, E77, E220, E644 Elastic Recovery of Bituminous Materials by Ductilometer H-030 Ductility mold with straight sides H-050 Ductility Testing Machine, 3-Speed for standard tests H-2600.63F H-260.63C ASTM Thermometer ASTM Thermometer H-393FS20 No. 20 Sieve, 3 in dia. H-393FS50 No. 50 Sieve, 3 in. dia. H-068B Ductility Testing Machine, 3-Speed w/temperature-control 3 circulator Note: Also required but not part of basic set Scissors and optional H-068PC plastic cover for constant temperature control. For 220V applications, substitute: H-050 with H-050.5F Ductility Testing Machine, 3-Speed for standard tests, 220V 50Hz H-060 with H-060.5F Ductility Testing Machine, 3-Speed refrigerated/standard & forced tests, 220V 50Hz H-068 with H-068.5F Ductility Testing Machine, 3-Speed w/temperature-control circulator for standard and forced tests, 220V 50Hz 52

ASTM D6925 Related Standards: ASTM D88, D204, D2726, D4402, D4753; AASHTO Standards: PP35, T32, TP4 Preparation and Determination of Relative Density of Hot Mix Asphalt (HMA) by Means of the Superpave Gyratory Compactor 2 H-635 Superpave Gyratory Compactor H-635. 50mm mold assembly H-635.4 50mm paper disc Note: Also required but not part of basic set Thermometers, balance and ovens (2). For 220V applications, substitute: H-H-635 with H-H-635.4F Superpave Gyratory Compactor, 220V 50/60Hz 53

Related Standards: ASTM D27, D2493, D4402, E ASTM D6926 Preparation of Bituminous Specimens Using Marshall Apparatus 2 H-364 H-364R H-336D H-346D H-356D H-34A H-337 H-367 H-348 H-363 H-353A H-355 Heavy-duty automatic single compactor,5v 60Hz Heavy-duty automatic, rotating single compactor, 5V 60Hz Single Marshall automatic compactor, 5V 60Hz Double Marshall automatic compactor, 5V 60Hz Triple Marshall automatic compactor, 5V 60Hz Compaction mold for 4 (Stationary Base) Compaction mold for 4 (Rotating Base) Compaction mold for 6 (Rotating or Stationary Base) Mold extractor, 4 inch Mold extractor, 6 inch Hand-operated sample ejector Motorized sample ejector, 20V 60Hz H-390 Constant Temperature Water Bath, 0V 60Hz H-384 ASTM-compliant Mixer, 5Qt., 20V 60Hz H-4952 Heavy-duty Hotplate, 20V 60Hz H-3760 Triangular Trowel H-33 Marshall sample storage can Note: Also required but not part of basic set Weighing balance, thermometers, various containers and labware.. For 220V applications, substitute: H-364 with H-364.4F Heavy-duty automatic single compactor, 220V 50/60Hz H-364R with H-364R.4F Heavy-duty automatic single compactor, 220V 50/60Hz H-336D with H-336D.2F, 220V 60Hz or H-336D.5F, 220V 60Hz Automatic single compactor H-346D with H-346D.2F, 220V 60Hz or H-346D.5F, 220V 60Hz Automatic single compactor H-356D with H-356D.2F, 220V 60Hz or H-356D.5F, 220V 60Hz Automatic single compactor H-390 with H-390.4F Constant Temperature Water Bath, 220V 50/60Hz H-4952 with H-4952.4F Heavy-duty Hotplate, 220V 50/60Hz 54

ASTM D6927 ASTM C3 Related Standards: ASTM C670, D2726, D3549, D6926 Marshall Stability and Flow of Bituminous Mixtures H-303 Bench oven H-342 Breaking head, 4" HM-327MAR Marshall/TSR Loader with Load Cell, Strain Transducer and HMTS Marshall Module Software, 5V 60Hz H-390 Constant temperature water bath H-4952 Heavy-duty hotplate Note: Also required but not part of basic sets Thermometers and in case of cutback binder and air bath. For 220V applications, substitute: H-303 with H-303.4F Bench oven, 220V 50/60Hz HM-327MAR with HM-327MAR.5F, 220V 50Hz H-390 with H-390.4F Constant Temperature Water Bath, 220V 50/60Hz H-4952 with H-4952.4F Heavy-duty Hotplate, 220V 50/60Hz 55

.800.544.7220 www.humboldtmfg.com HUMBOLDT MFG. CO. 875 Tollgate Road Elgin, IL 6023