a Nexans company Medium voltage symmetrical separable connectors - Interface C -

a Nexans company Catalogue 2015

INTERFACE C MEDIUM VOLTAGE SYMMETRICAL SEPARABLE CONNECTORS CATALOGUE 2017

a Nexans company Catalogue 2009

THORNE & DERRICK UK TEL FAX TEL FAX

a Nexans company Catalogue 2007

a Nexans company Catalogue 2009

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

INTERFACE F MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

a Nexans company Catalogue 2011

a Nexans company Catalogue 2006

a Nexans company Catalogue 2012

Nexans Network Solutions Div. Euromold

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2007

THORNE & DERRICK UK TEL FAX TEL FAX

a Nexans company Catalogue 2008

Power cables accessories for use in potentially explosive atmospheres

a Nexans company Catalogue 2009

INTERFACE A MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

a Nexans company Catalogue 2015

ACCESSORIES. Application For use with connectors and bushings with an interface C as described by CENELEC EN and

Nexans Network Solutions Div. Euromold

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2008

global leader in cables

Shielded surge arresters

High Voltage Accessories up to 72.5 kv

(K),(M),(P)489TB/G Up to 42 kv

(K),(M)430TB/G Up to 36 kv

a Nexans company Catalogue 2012

power cable accessories

ENERGIE - KABELGARNITUREN ACCESSOIRES POUR CÂBLES D ÉNERGIE

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Cold-shrinkable Silicone 12 kv - 24 kv - 36 kv

Energy Division. PCA Single Column Polymeric Surge Arrester

Separable Connectors and Kits


H e a t s h r i n k P r o d u c t G u i d e

Cellplux Plug-in Technology

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )


NXPLUS C Single busbar. Maintenance-free for lifetime

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Medium Voltage. Joints & Terminations

TE S RAYCHEM RSTI-CC-58 SCREENED, SEPARABLE COUPLING SYSTEM

Power cable accessories catalogue

Completing the picture

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

Nexans Switzerland. Global expert in cables and cabling system. Cossonay Production Plant

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

600 A 15 kv class T-OP II deadbreak connector

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

3 TM Cold Applied Barrier Boot System

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Zinc Oxide Surge Arrester PEXLIM Q

ELASTIMOLD UNDERGROUND CABLE ACCESSORIES

Surge arrester POLIM-H..SD

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

Gas Insulated Switchgear

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

IEC Separable Connectors 17.5 kv/24 kv, 630A

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

Loadbreak Apparatus Connectors

8DJ. Maintenance-free for lifetime

ELB ES. Product Installation Instructions

Zinc-Oxide Surge Arrester TEXLIM Q-C

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

DURAREEL TRAILING REELING CABLE

Surge arrester POLIM-H.. ND

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

MEDIUM VOLTAGE NETWORKS

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Bowthorpe EMP LV/MV Outdoor Surge Arresters

INSTALLATION PRODUCTION TESTS

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

SERIES TAP-CHANGER

your Green Power WIND POWER SOLUTIONS only Greener

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

IS90750-ENG - 430TB/G-45/LCA 14 January 201 O - Revision 7 - Supersedes edition of 25 June 2009 Page 1 of 9

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Zinc Oxide Surge Arrester EXLIM R

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

3EK7 Medium Voltage Silicone Insulated Surge Arresters

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

Transcription:

a Nexans company Catalogue 2011

Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: premoulded EPDM rubber s for cables and epoxy bushings for transformers and switchgear, as well as a large range of coldshrinkable terminations and joints from 12 to 42 kv. Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group. ISO 9001 Certificate Since 1992, Euromold s commitment to quality is demonstrated by its ISO 9001 certification. International standards All our products meet the International standards like CENELEC HD 629.1, CENELEC EN 50180, IEC 60137, IEC 60502-4 or country specifications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are continuously performed in our test fields. Laboratory accreditation Since June 2000, Euromold s independent ELAB laboratory obtained the BELAC accreditation no.144-test conform with the European standards for laboratories ISO 17025 for electrical testing of low and medium voltage cable accessories according to the international standards EN 50393, IEC 60502-4, IEC 61442 and HD 629. While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as standards and technology evolve. 1

SEPARABLE CONNECTORS INTERFACE C Table of contents 430TB - tee 484TB - tee 300PBM - coupling 430TBM-P2/P3 - dual/triple cable arrangement 804PB - coupling 300SA - surge arrester 800SA - surge arrester 400TR and 800TR - test rod 400TK and 400SW installation tools Accessories Possible arrangements Dia. 56 ±0.2 Interface C1 & C2 Dimensions according to European CENELEC EN 50180 and 50181 (in mm). Dia. 46 ±0.2 M16 x 2-6H Dia. 22 min for C1 Dia. 32 nominal for C2 0 1.5-0.5 29 min. 90 ±0.2 11 min. Dia. 70 ±0.2 2

Connecting possibilities BUSHINGS / ACCESSORIES CONNECTION CONNECTORS / ACCESSORIES Equipment interface dead-ending of equipment (K)(M)400DR-B Dead-end receptacle (K)(M)400AR-3 Equipment bushing (K)(M)400AR-4 Equipment bushing (K)(M)400AR-5 Equipment bushing cable to equipment (K)(M)430TB/G Tee (K)(M)300PBM/G Coupling (K)(M)400AR-6 Equipment bushing (K)(M)400SFR-B Equipment bushing 300SA Surge arrester 400A-24B In-air bushing (K)(M)400SOP-B Stand-off plug cable isolation 400GP-B Earthing plug (K)400RTPA Reducing tap plug cable earthing tap-off /250A (K)(M)484TB/G Tee (K)(M)804PB/G Coupling (K)(M)400CP-SC Connecting plug in-line junction For information on our bushings please refer to our bushing catalogue. 800SA Surge arrester 3

Application Separable tee shape (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors,...). Also connects cable to cable when using the appropriate mating parts. Technical characteristics A thick conductive EPDM jacket provides a total safe to touch screen. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. 430TB INTERFACE C TEE CONNECTOR Up to kv A (800 A) 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 () kv 19/33 () kv Design Separable comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type C interface as described by CENELEC EN 50180 and 50181. 5. Conductor. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Clamping screw.. Earthing lead. The screen break design enables cable outer sheath testing without removing or dismantling the. 290 mm (350 mm for kv) 4 9 5 1 2 3 185 mm 8 6 Specifications and standards The 430TB separable meets the requirements of CENELEC HD 629.1. 7 Separable type Voltage Um (kv) Current Ir (A) Current Ir (A) When installed on an appropriate equipment Conductor sizes (mm 2 ) bushing and when using a copper (-11-2) or a bolted (-12-5 or -14-5) conductor contact min max 430TB/G K430TB/G M430TB/G 12 24 800 800 800 35 35 50 300 300 240 4

Kit contents The complete (K)(M)430TB/G tee kit comprises 3 x the following components: The kit also comprises silicone grease, field control mastic, installation rod, installation instructions and crimp chart. Conductor contact TMBC-X 3 x (K)(M)430TB/G-W-X kit Connector housing (K)(M)430BT/G Clamping screw 430TCS Conductor contact TBC-X Basic insulating plug (K)(M)300BIPA + rubber cap Cable reducer 430CA-W (411CA-W for kv) To order the tee, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Example: The cable is 24 kv, 150 mm 2 compact stranded copper with a diameter over core insulation of 27.5 mm. Order 3 x K430TB/G-18-95.240-14-5 tee kit. Table W Table X Ordering part number 3 x 430TB/G-11-X 3 x 430TB/G-16-X 3 x 430TB/G-18-X 3 x K430TB/G-11-X 3 x K430TB/G-16-X 3 x K430TB/G-18-X 3 x M430TB/G-11-X 3 x M430TB/G-15-X 3 x M430TB/G-19-X 3 x M430TB/G-22-X 3 x M430TB/G-25-X 3 x M430TB/G-27-X Voltage (Um) (kv) 12 12 12 24 24 24 Dia. over core insulation (mm) min 12.0 17.0 19.0 12.0 17.0 19.0 12.0 16.0 20.0 23.5 26.5 28.5 max 17.5 23.5 32.6 17.5 23.5 32.6 17.5 22.0 26.5 31.0 32.5 37.5 Conductor sizes (mm 2 ) Aluminium conductor DIN hexagonal Deep indent Aluminium and copper conductor Bolted Copper conductor DIN hexagonal 35 35(K)M--2 35KM--1 35(K)M-11-2 50 50(K)M--2 50(K)M--1 50(K)M-11-2 70 70(K)M--2 70(K)M--1 70(K)M-11-2 95 95(K)M--2 95(K)M--1 95(K)M-11-2 120 120(K)M--2 120(K)M--1 120(K)M-11-2 150 150(K)M--2 150(K)M--1 150(K)M-11-2 185 185(K)M--2 185(K)M--1 185(K)M-11-2 240 240(K)M--2 240(K)M--1 240(K)M-11-2 300 300(K)M--2 300(K)M-11-2 16.95-14-5 50.150-14-5 95.240-14-5 120.300-12-5 For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-226 cables. Please contact our representative. For use with easy strip semi-conductive screened cables. Order: Field control mastic (type MFC). For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. When installed on an appropriate equipment bushing: 800 A continuously 5

Application Separable tee shape (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors,...). Also connects cable to cable when using the appropriate mating parts. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. 484TB INTERFACE C TEE CONNECTOR Up to 42 kv A (1250 A) 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 () kv 19/33 () kv 20.8/ (42) kv Design Separable comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type C - interface as described by CENELEC EN 50180 and 50181. 5. Conductor. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Clamping screw.. Earthing lead. 0 mm 4 9 5 1 2 3 185 mm 8 6 The screen break design enables cable outer sheath testing without removing or dismantling the. Specifications and standards The 484TB separable meets the requirements of CENELEC HD 629.1. 7 Separable type 484TB/G K484TB/G M484TB/G P484TB/G Voltage Um (kv) 12 24 42 Current Ir (A) Current Ir (A) When installed on an appropriate equipment bushing 1250 1250 1250 1250 Conductor sizes (mm 2 ) min 50 35 35 35 max 6

Kit contents The complete (K)(M)(P)484TB/G tee kit comprises 3x the following components: The kit also comprises silicone grease, field control mastic, gloves, roll adhesive tape, installation instructions and crimp chart. Conductor contact TMBC-X (K)(M)(P)484TB/G-W-X kit Connector housing (K)(M)(P)484BT/G Clamping screw 430TCS Conductor contact TBC-X Basic insulating plug (K)(M)(P)800BIPA + rubber cap Cable reducer 611CA-W To order the tee, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv, add an 'M' for use up to kv, add a 'P' for use up to 42 kv. Table W Table X Ordering part number 3 x 484TB/G-15-X 3 x 484TB/G-19-X 3 x 484TB/G-22-X 3 x 484TB/G-27-X 3 x 484TB/G-32-X 3 x 484TB/G-37-X 3 x 484TB/G-43-X Dia. over core insulation (mm) min 16.0 20.0 23.5 28.5 34.0 39.0 45.5 max 22.0 26.5 31.0 37.5 42.5 48.5 56.0 Example: The copper wire screened cable is kv, 240 mm 2 stranded aluminium with a diameter over core insulation of 37.0 mm. Order 3 x M484TB/G-32-240(K)M-12-2 tee kit. Conductor sizes (mm 2 ) 35 50 70 95 120 150 185 240 Aluminium conductor DIN hexagonal 35(K)M-12-2 50(K)M-12-2 70(K)M-12-2 95(K)M-12-2 120(K)M-12-2 150(K)M-12-2 185(K)M-12-2 240(K)M-12-2 Deep indent 35KM-12-1 50KM-12-1 70KM-12-1 95KM-12-1 120KM-12-1 150KM-12-1 185KM-12-1 240KM-12-1 16.95-14-5 Aluminium and copper conductor 50.150-14-5 Bolted 95.240-14-5 120.300-12-5 Copper conductor DIN hexagonal 35(K)M-11-2 50(K)M-11-2 70(K)M-11-2 95(K)M-11-2 120(K)M-11-2 150(K)M-11-2 185(K)M-11-2 240(K)M-11-2 300 300(K)M-12-2 300KM-12-1 300(K)M-11-2 400 400(K)M-12-2 400KM-12-1 400(K)M-11-2 500 500(K)M-12-2 500KM-12-1 500(K)M-11-2 KM-12-1 (K)M-11-2 For use with copper tape screened cables. Order: Kit MT. For use with copper wire screened cables. No earthing device is necessary. For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. Components can be ordered individually. When installed on an appropriate equipment bushing: 1250 A continuously 7

Application Separable coupling (bolted type) for dual cable arrangement. It has been designed to be used with 430TB separable Tee. Technical characteristics A thick conductive EPDM jacket provides a total safe to touch screen. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. 300PBM COUPLING CONNECTOR FOR 430TB/G Up to kv A (1250 A) 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 () kv 19/33 () kv Design 1. Interface designed to fit 430TB. 2. Bus for 300PBM. 3. Conductive EPDM insert. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Conductive EPDM jacket. 6. Conductive EPDM cap. 7. Basic insulating plug (with VD point). 8. Conductor (hexagonal crimping, deep indent crimping or bolted). 9. Cable reducer.. Earthing lead. The screen break design enables cable outer sheath testing without removing or dismantling the. 290 mm (350 mm for kv) 1 430TB 290 mm 2 8 3 4 5 6 7 300PBM coupling Specifications and standards The 300PBM coupling meets the requirements of CENELEC HD 629.1. 9 5 mm Separable type Voltage Um (kv) Current Ir (A) Current Ir (A) When installed on an appropriate equipment Conductor sizes (mm 2 ) bushing and when using a copper (-11-2) or a bolted (-12-5 or -14-5) conductor contact min max 300PBM/G K300PBM/G M300PBM/G 12 24 1250 1250 1250 35 35 50 300 300 240 8

Kit contents The complete (K)(M)300PBM/G coupling kit comprises 3 x the following components: The kit also comprises silicone grease, field control mastic, installation rod, installation instructions and crimp chart. Conductor contact TMBC-X 3 x (K)(M)300PBM/G-W-X coupling kit Cable reducer 430CA-W Connector housing (K)(M)300BP/G Contact rod 300PB-CR Conductor contact TBC-X (411CA-W for kv) To order the coupling, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Example: The cable is 24 kv, 150 mm 2 compact stranded copper with a diameter over core insulation of 27.5 mm. Order 3 x K300PBM/G-18-95.240-14-5 coupling kit. Table W Table X Ordering part number 3 x 300PBM/G-11-X 3 x 300PBM/G-16-X 3 x 300PBM/G-18-X 3 x K300PBM/G-11-X 3 x K300PBM/G-16-X 3 x K300PBM/G-18-X 3 x M300PBM/G-11-X 3 x M300PBM/G-15-X 3 x M300PBM/G-19-X 3 x M300PBM/G-22-X 3 x M300PBM/G-25-X 3 x M300PBM/G-27-X Voltage (Um) (kv) 12 12 12 24 24 24 Dia. over core insulation (mm) min 12.0 17.0 19.0 12.0 17.0 19.0 12.0 16.0 20.0 23.5 26.5 28.5 max 17.5 23.5 32.6 17.5 23.5 32.6 17.5 22.0 26.5 31.0 32.5 37.5 Conductor sizes (mm 2 ) Aluminium conductor DIN hexagonal Deep indent Aluminium and copper conductor Bolted Copper conductor DIN hexagonal 35 35(K)M--2 35KM--1 35(K)M-11-2 50 50(K)M--2 50(K)M--1 50(K)M-11-2 70 70(K)M--2 70(K)M--1 70(K)M-11-2 95 95(K)M--2 95(K)M--1 95(K)M-11-2 120 120(K)M--2 120(K)M--1 120(K)M-11-2 150 150(K)M--2 150(K)M--1 150(K)M-11-2 185 185(K)M--2 185(K)M--1 185(K)M-11-2 240 240(K)M--2 240(K)M--1 240(K)M-11-2 300 300(K)M--2 300(K)M-11-2 16.95-14-5 50.150-14-5 95.240-14-5 120.300-12-5 For use with copper tape screened cables. Order: Kit MT. For use with fabric tape (graphite) screened cables. Order additional semi-conductive tape (type TSC). For use with easy strip semi-conductive screened cables. Order: Field control mastic (type MFC). For use with copper wire screened cables. No earthing device is necessary. For use with other cable types. Please contact our representative. For outdoor applications. Order: +MWS. 9

Application Separable s (bolted type) for dual (P2) and triple (P3) cable arrangements. Technical characteristics A thick conductive EPDM jacket provides a total safe to touch screen. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. 430TBM-P2/P3 DUAL/TRIPLE CABLE ARRANGEMENT FOR 430TB CONNECTOR Up to kv A (1250 A) 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 () kv 19/33 () kv Design 1. Type C interface as described by CENELEC EN 50180 and 50181. 2. Bus for 300PBM. 3. Conductive EPDM insert. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Conductive EPDM jacket. 6. Conductive EPDM cap. 7. Basic insulating plug (with VD point). 8. Conductor. 9. Cable reducer.. Earthing lead. The screen break design enables cable outer sheath testing without removing or dismantling the. Specifications and standards The 430TBM-P2/P3 s meet the requirements of CENELEC HD 629.1. 1 Non-size sensitive: 290 mm Size sensitive: 350 mm 430TBM 290 mm 2 8 3 4 5 9 5 mm 6 7 300PBM coupling Separable type Voltage Um (kv) Current Ir (A) Current Ir (A) When installed on an appropriate equipment Conductor sizes (mm 2 ) bushing and when using a copper (-11-2) or a bolted (-12-5 or -14-5) conductor contact min max 430TBM-P2/P3 K430TBM-P2/P3 M430TBM-P2/P3 12 24 1250 1250 1250 35 35 50 300 300 240

Kit contents The complete (K)(M)430TBM-P2 kit comprises 3 x the following components: 290 300BIPA basic insulating plug 300PBM coupling 430TB tee The complete (K)(M)430TBM-P3 kit comprises 3 x the following components: 395 300BIPA basic insulating plug 300PBM coupling s 430TB tee 1 5 1 5 5 In mm. To order the separable s for dual cable arrangement, use the tables beside to substitute for W and X in the formula: 3 x 430TBM-P2-W-X, for use up to 12 kv. Add a 'K' for use up to 24 kv: 3 x K430TBM-P2-W-X. Add an 'M' for use up to kv: 3 x M430TBM-P2-W-X. For triple cable arrangement: 3 x 430TBM-P3-W-X, for use up to 12 kv. Add a 'K' for use up to 24 kv: 3 x K430TBM-P3-W-X. Add an 'M' for use up to kv: 3 x M430TBM-P3-W-X. Example: The two cables are 24 kv, 150 mm 2 stranded aluminium with a diameter over core insulation of 27.5 mm. Order 3 x K430TBM-P2-22- 150(K)M--2. 1. From table W: select the symbol which gives the best centring of your core insulation diameter. 2. From table X: according to your conductor size and type, select the designation which completes the part number. Table X Conductor sizes (mm 2 ) Aluminium conductor DIN hexagonal Deep indent Table W Dia. over core insulation (mm) min 12.0 16.0 20.0 23.5 26.5 28.5 max 17.5 22.0 26.5 31.0 32.5 37.5 Aluminium and copper conductor Bolted W 11 15 19 22 25 27 Copper conductor DIN hexagonal 35 35(K)M--2 35KM--1 35(K)M-11-2 50 50(K)M--2 50(K)M--1 50(K)M-11-2 70 70(K)M--2 70(K)M--1 70(K)M-11-2 95 95(K)M--2 95(K)M--1 95(K)M-11-2 120 120(K)M--2 120(K)M--1 120(K)M-11-2 150 150(K)M--2 150(K)M--1 150(K)M-11-2 185 185(K)M--2 185(K)M--1 185(K)M-11-2 240 240(K)M--2 240(K)M--1 240(K)M-11-2 300 300(K)M--2 300(K)M-11-2 16.95-14-5 50.150-14-5 95.240-14-5 120.300-12-5 For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-226 cables. Please contact our representative. For use with other cable types. Please contact our representative. For use with easy strip semi-conductive screened cables. Order: Field control mastic (type MFC). For applications outdoors and in humid climate. Order: +MWS. When installed on an appropriate equipment bushing: 1250 A continuously 11

Application Separable coupling (bolted type) for dual cable arrangement. It has been designed to be used with 484TB separable Tee. Technical characteristics A thick conductive EPDM jacket provides a total safe to touch screen. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. 804PB COUPLING CONNECTOR FOR 484TB/G Up to 42 kv A (1250 A) 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 () kv 19/33 () kv 20.8/ (42) kv Design 1. Interface designed to fit 484TB. 2. Bus for 804PB. 3. Conductor (hexagonal crimping, deep indent crimping or bolted). 4. Conductive EPDM insert. 5. Conductive EPDM jacket. 6. Insulating EPDM layer moulded between the insert and the jacket. 7. Cable reducer. 8. Conductive EPDM cap. 9. Basic insulating plug (with VD point).. Earth lead. The screen break design enables cable outer sheath testing without removing or dismantling the. 0 mm 1 484TB 290 mm 2 3 4 5 6 8 9 Specifications and standards The 804PB coupling meets the requirements of CENELEC HD 629.1. 7 1 mm Separable type 804PB/G K804PB/G M804PB/G P804PB/G Voltage Um (kv) 12 24 42 Current Ir (A) Current Ir (A) When installed on an appropriate equipment bushing 1250 1250 1250 1250 Conductor sizes (mm 2 ) min 50 35 35 35 max 12

Kit contents The complete (K)(M)(P)804PB/G coupling kit comprises 3 x the following components: The kit also comprises silicone grease, field control mastic, gloves, roll adhesive tape, installation instructions and crimp chart. Conductor contact TMBC-X 3 x (K)(M)(P)804PB/G-W-X coupling kit Connector housing (K)(M)(P)804BP/G Contact rod and stud Conductor contact TBC-X Cable reducer 611CA-W To order the coupling, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv, add an 'M' for use up to kv, add a 'P' for use up to 42 kv. Table W Table X Ordering part number 3 x 804PB/G-15-X 3 x 804PB/G-19-X 3 x 804PB/G-22-X 3 x 804PB/G-27-X 3 x 804PB/G-32-X 3 x 804PB/G-37-X 3 x 804PB/G-43-X Dia. over core insulation (mm) min 16.0 20.0 23.5 28.5 34.0 39.0 45.5 max 22.0 26.5 31.0 37.5 42.5 48.5 56.0 Example: The copper wire screened cable is kv, 240 mm 2 stranded aluminium with a diameter over core insulation of 37.0 mm. Order 3 x M804PB/G-32-240(K)M-12-2 coupling kit. Conductor sizes (mm 2 ) 35 50 70 95 120 150 185 240 Aluminium conductor DIN hexagonal 35(K)M-12-2 50(K)M-12-2 70(K)M-12-2 95(K)M-12-2 120(K)M-12-2 150(K)M-12-2 185(K)M-12-2 240(K)M-12-2 Deep indent 35KM-12-1 50KM-12-1 70KM-12-1 95KM-12-1 120KM-12-1 150KM-12-1 185KM-12-1 240KM-12-1 16.95-14-5 Aluminium and copper conductor 50.150-14-5 Bolted 95.240-14-5 120.300-12-5 Copper conductor DIN hexagonal 35(K)M-11-2 50(K)M-11-2 70(K)M-11-2 95(K)M-11-2 120(K)M-11-2 150(K)M-11-2 185(K)M-11-2 240(K)M-11-2 300 300(K)M-12-2 300KM-12-1 300(K)M-11-2 400 400(K)M-12-2 400KM-12-1 400(K)M-11-2 500 500(K)M-12-2 500KM-12-1 500(K)M-11-2 KM-12-1 (K)M-11-2 For use with copper tape screened cables. Order: Kit MT. For use with copper wire screened cables. No earthing device is necessary. For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. Components can be ordered individually. When installed on an appropriate equipment bushing: 1250 A continuously 13

Application Surge arrester designed to protect 12, 24 and kv class components, including transformers, equipment, cable and accessories from high voltage surges resulting from lightning or switching. It has been designed to be used with the 430TB separable tee. Technical characteristics This surge arrester is a metal oxide varistor surge arrester in an elbow configuration. Each arrester is tested for AC withstand, partial discharge and critical voltage prior to leaving the factory. 300SA SURGE ARRESTER FOR 430TB CONNECTOR Up to kv 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 () kv 19/33 () kv Design Surge arrester comprising: 1. Interface designed to fit the 430TB/G tee. 2. Conductive EPDM insert. 3. Conductive EPDM jacket. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Receptacle for contact rod. 6. Metal oxide valve elements. 7. Steel cap. 8. Earth connection. 9. Earth lead. L2 1 5 2 3 170 mm 5 mm Dia. 75 mm 9 Specifications and standards The 300SA surge arresters meet the test requirements of IEC 60099-4. L1 4 6 Dia. 65 mm 7 8 Surge arrester type Nominal discharge current In (ka) Rated voltage Ur (kv) Max. continuous operating voltage Uc (kv) L1 Dimensions (mm) L2 300SA--15N 300SA--18N 300SA--22N 300SA--24N 300SA--30N 300SA--N 300SA--45N 15 18 22 24 30 45 12.0 14.4 17.6 19.2 24.0 28.8.0 250 250 250 350 350 350 450 290 290 290 390 390 390 490 14

Typical application and dimensions 290 mm 180 mm 7 mm To order the surge arrester, specify the surge arrester type, as described on previous page. Example: For a maximum continuous operating voltage (r.m.s.) of 24 kv and a nominal discharge current of ka. Order a 300SA--30N surge arrester. Type 300SA surge arrester Type 430TB tee Technical data Surge arrester type Steep current residual voltage @ ka [1/20 µs] (kv) Lightning current residual voltage [8/20 µs] (kv) Switching impulse residual voltage [/90 µs] (kv) @ 5 ka @ ka @ 20 ka @ 125 A @ 500 A High current impulse withstand (ka) 300SA--15N 300SA--18N 300SA--22N 300SA--24N 300SA--30N 300SA--N 300SA--45N 48.1 58.1 70.1 77.0 97.0 115.9 144.1 39.7 48.0 57.9 63.6 80.1 95.7 119.0 43.2 52.2 63.0 69.2 87.2 4.2 129.5 48.4 58.5 70.6 77.6 97.7 116.8 145.1 30.5.8 44.4 48.8 61.5 73.5 91.3 32.5 39.2 47.3 52.0 65.5 78.3 97.3 0 0 0 0 0 0 0 15

Application Surge arrester designed to protect 12, 24, and 42 kv class components, including transformers, equipment, cable and accessories from high voltage surges resulting from lightning or switching. It has been designed to be used with the 484TB separable tee. Technical characteristics This surge arrester is a metal oxide varistor surge arrester in an elbow configuration. Each arrester is tested for AC withstand, partial discharge and critical voltage prior to leaving the factory. 800SA SURGE ARRESTER FOR 484TB CONNECTOR Up to 42kV 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 () kv 19/33 () kv 20.8/ (42) kv Design Surge arrester comprising: 1. Interface designed to fit the 484TB tee. 2. Conductive EPDM insert. 3. Conductive EPDM jacket. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Receptacle for contact rod. 6. Metal oxide valve elements. 7. Steel cap. 8. Earth connection. 9. Earth lead. L2 1 5 2 170 mm 5 mm Dia. 75 mm 3 L1 9 Specifications and standards The 800SA surge arresters meet the test requirements of IEC 60099-4. 4 6 7 8 Dia. 65 mm Surge arrester type Nominal discharge current In (ka) Rated voltage Ur (kv) Max. continuous operating voltage Uc (kv) L1 Dimensions (mm) L2 800SA--15N 800SA--18N 800SA--22N 800SA--24N 800SA--30N 800SA--N 800SA--45N 15 18 22 24 30 45 12.0 14.4 17.6 19.2 24.0 28.8.0 250 250 250 350 350 350 450 290 290 290 390 390 390 490 16

Typical application and dimensions 290 mm 180 mm 1 mm To order the surge arrester, specify the surge arrester type, as described on previous page. Example: For a maximum continuous operating voltage (r.m.s.) of 24 kv and a nominal discharge current of ka. Order a 800SA--30N surge arrester. Type 484TB tee Type 800SA surge arrester Technical data Surge arrester type Steep current residual voltage @ ka [1/20 µs] (kv) Lightning current residual voltage [8/20 µs] (kv) Switching impulse residual voltage [/90 µs] (kv) @ 5 ka @ ka @ 20 ka @ 125 A @ 500 A High current impulse withstand (ka) 800SA--15N 800SA--18N 800SA--22N 800SA--24N 800SA--30N 800SA--N 800SA--45N 48.1 58.1 70.1 77.0 97.0 115.9 144.1 39.7 48.0 57.9 63.6 80.1 95.7 119.0 43.2 52.2 63.0 69.2 87.2 4.2 129.5 48.4 58.5 70.6 77.6 97.7 116.8 145.1 30.5.8 44.4 48.8 61.5 73.5 91.3 32.5 39.2 47.3 52.0 65.5 78.3 97.3 0 0 0 0 0 0 0 17

400TR and 800TR INTERFACE C TEST RODS Application The test rod can be used for: - cable fault location - cable testing - phasing checks, etc. Connections may be made with a cable lug, a 4 mm plug or spring clips. Technical characteristics The 400TR test rod can be used with 430TB s. The 800TR is for use with the 484TB. Design 1. Insulating shroud. 2. Threaded rod for test connection. 3. Two nuts M12. 4. Insulation. 5. Copper test rod stem. 6. Wing nut. An insulating shroud is provided to allow the application of test voltages when bushings are closely spaced. 1 2 3 400TR M12 40 1 2 3 800TR M12 Installation The test rod is mounted on to the clamping screw in the type C interface tee and coupling s. The test cable is connected to the threaded stem and the insulating shroud moved to its final position over the end of the test rod. 4 288 5 480 4 5 321,5 480 Simply specify: 400TR or 800TR test rod. In mm. Test rod type Maximum A.C. test voltage (50 Hz - 1 min) Maximum D.C. test voltage (8 x U 0-30 min) Impulse voltage (1.2 x 50 µs) min 400TR 800TR kv kv 96 kv 96 kv 95 kv 95 kv 18

400TK and 400SW INSTALLATION TOOL Application The box spanner and box spanner key are designed to facilitate assembly of 400TE, 400TB and 440TB s. The 400TK box spanner is used to install the 400TEF clamping pin contact or 400TCS clamping screw. The 400SW box spanner key fits on the hex nut of the 400BIPA basic insulating plug. 400TK 400SW Simply specify: - 400TK box spanner - 400SW box spanner key 19

ACCESSORIES INTERFACE C Application For use with s and bushings with an interface C as described by CENELEC EN 50180 and 50181. 400DR-B Dead-end receptacle Fits over a bushing with a type C interface to provide 'deadend' facility. 400SOP-B Stand-off plug Is designed to support and 'dead-end' s with a type C interface when removed from equipment. Technical characteristics All these products, except the earthing plugs, are tested for AC withstand and partial discharge prior to leaving the factory. Up to kv 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 () kv 19/33 () kv 20,8/ (42) kv Order 400DR-B for 12 kv, K400DR-B for 24 kv or M400DR-B for kv applications. The dead-end receptacle can be supplied with an earth lead. Order with suffix -/G. E.g. K400DR-B/G. Order 400SOP-B for 12 kv, K400SOP-B for 24 kv, M400SOP-B for kv or P400SOP-B for 42 kv applications. 400GP-B Earthing plug Is designed to support and earth s with a type C interface when removed from equipment. Order 400GP-B for 12, 24, or 42 kv applications. 300GP-B Earthing plug Is designed to earth the 430TB s when it is fixedmounted to the equipment (maintenance earthing). Order 300GP-B for 12, 24, or 42 kv applications. 20

800GP-B Earthing plug Is designed to earth the 484TB s when it is fixedmounted to the equipment (maintenance earthing). Order 800GP-B for 12, 24, or 42 kv applications. 400BIPA Basic insulating plug Acts as a tightening nut for the 400TB and 440TB tee kits. The plug contains a voltage detection point. The conductive rubber protection cap is included. Order 400BIPA for 12 kv, K400BIPA for 24 kv M400BIPA for kv or P400BIPA for 42 kv applications. Kit MT Earthing kit for copper tape screened cables Contains a tinned copper braid (25 mm² - L = 500 mm), a tinned copper wire for cleating and some water sealing mastic. Order Kit MT for 12 kv, 24 kv kv or 42 kv applications. 21

POSSIBLE ARRANGEMENTS INTERFACE C 430TB Single cable arrangement. Order 430TB for 12 kv, K430TB for 24 kv or M430TB for kv applications. 430TBM-P2 Dual cable arrangement. Order 430TBM-P2 for 12 kv, K430TBM-P2 for 24 kv or M430TBM-P2 for kv applications. 290 300BIPA basic insulating plug 300PBM coupling 430TB tee 1 5 430TBM-P3 Triple cable arrangement. Order 430TBM-P3 for 12 kv, K430TBM-P3 for 24 kv or M430TBM-P3 for kv applications. 430TBM-L3 3-way connection. Order 430TBM-L3 for 12 kv, K430TBM-L3 for 24 kv or M430TBM-L3 for kv applications. 395 425 300BIPA basic insulating plug 300PBM coupling s 400BIPA basic insulating plug 300BIPA basic insulating plug 300PBM coupling s 430TB tee 430TB tee 1 5 5 In mm. 22

484TB Single cable arrangement. Order 484TB for 12 kv, K484TB for 24 kv, M484TB for kv or P484TB for 42 kv applications. 185 800BIPA basic insulating plug 484TB-P2 Dual cable arrangement. Order 484TB-P2 for 12 kv, K484TB-P2 for 24 kv or M484TB-P2 for kv or P484TB-P2 for 42kV applications. 290 800BIPA basic insulating plug 484TB tee 804PB coupling 1 1 1 484TB tee 484TB-P2 + 800SA Dual cable arrangement with surge arrester. Order 484TB-P2+800SA for 12 kv, K484TB-P2+800SA for 24 kv, M484TB-P2+800SA for kv or P484TB-P2+800SA for 42 kv applications. 400 800BIPA basic insulating plug 800SA surge arrester 1 1 484TB tee 804PB coupling 23

Earthing plug on Order 300GP-B for 12 kv, 24 kv and kv applications. Order 800GP-B for 12 kv, 24 kv, kv or 42 kv applications. 800GP-B earthing plug 484TB tee Cable and equipment testing 800TR test rod insulating schroud 484TB tee 1 In mm. 24

Additional catalogue information on power cable accessories is available by contacting us at the address below: Distributed by: a Nexans company Nexans Network Solutions N.V. - Div. Euromold Zuid III, Industrielaan 12, B-9320 Erembodegem Tel.: +32 (0)53 85 02 11 Fax: +32 (0)53 83 13 www.nexans.com info.euromold@nexans.com Catalogue also available on CD-ROM