INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

Similar documents
INTERFACE F MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

a Nexans company Medium voltage symmetrical separable connectors - Interface C -

INTERFACE C MEDIUM VOLTAGE SYMMETRICAL SEPARABLE CONNECTORS CATALOGUE 2017

a Nexans company Catalogue 2011

a Nexans company Catalogue 2009

THORNE & DERRICK UK TEL FAX TEL FAX

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2007

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2015

a Nexans company Catalogue 2009

a Nexans company Catalogue 2007

THORNE & DERRICK UK TEL FAX TEL FAX

a Nexans company Catalogue 2012

INTERFACE A MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

a Nexans company Catalogue 2008

a Nexans company Catalogue 2015

a Nexans company Catalogue 2006

a Nexans company Catalogue 2009

Nexans Network Solutions Div. Euromold

Power cables accessories for use in potentially explosive atmospheres

Nexans Network Solutions Div. Euromold

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2008

Shielded surge arresters

ACCESSORIES. Application For use with connectors and bushings with an interface C as described by CENELEC EN and

(K),(M),(P)489TB/G Up to 42 kv

High Voltage Accessories up to 72.5 kv

(K),(M)430TB/G Up to 36 kv

global leader in cables

a Nexans company Catalogue 2012

power cable accessories

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

Energy Division. PCA Single Column Polymeric Surge Arrester

Cold-shrinkable Silicone 12 kv - 24 kv - 36 kv

Separable Connectors and Kits

H e a t s h r i n k P r o d u c t G u i d e

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

Zinc-Oxide Surge Arrester TEXLIM Q-C


Medium Voltage. Joints & Terminations

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

Zinc Oxide Surge Arrester EXLIM R

Cellplux Plug-in Technology

IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Power cable accessories catalogue

Completing the picture

Nexans Switzerland. Global expert in cables and cabling system. Cossonay Production Plant

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

Zinc Oxide Surge Arrester PEXLIM Q

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

Transformer bushings, type GOH. Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide


1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

IEC Separable Connectors 17.5 kv/24 kv, 630A

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

TE S RAYCHEM RSTI-CC-58 SCREENED, SEPARABLE COUPLING SYSTEM

M-0. M-0... series control, monitoring and signalling devices. Ex e

ELASTIMOLD UNDERGROUND CABLE ACCESSORIES

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

3 TM Cold Applied Barrier Boot System

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

Transformer bushings, type GOA 250. Installation and maintenance guide

Wind Power Solutions. Make Energy Renewable and Reliable!

BUSHINGS: GENERAL INFORMATION

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

Gas Insulated Switchgear

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Transformer bushings, type GSA-OA Technical guide

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Surge arrester POLIM-H..SD

Bushings for High Voltage AC Applications

Bushing Insulators according to DIN and UNEL Standards

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

3EK7 Medium Voltage Silicone Insulated Surge Arresters

Company Directive STANDARD TECHNIQUE: CA3V/3. Relating to Procedures for Making 33kV CableTerminations

Nexans WINDLINK connection system. Nexans Power Accessories Germany GmbH

NXPLUS C Single busbar. Maintenance-free for lifetime

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

INSTALLATION PRODUCTION TESTS

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

Transcription:

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

NEXANS NETWORK SOLUTIONS DIV. EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: premoulded EPDM rubber connectors for cables and epoxy bushings for transformers and switchgear, as well as a large range of coldshrinkable terminations and joints from 12 to 42 kv. Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group. International standards All our products meet the International standards like CENELEC HD 629.1, CENELEC EN 50180, IEC 60137, IEC 60502-4 or country specifications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are continuously performed in our test fields. Laboratory accreditation Since June 2000, Euromold s independent ELAB laboratory obtained the BELAC accreditation no.144-test conform with the European standards for laboratories ISO 17025 for electrical testing of low and medium voltage cable accessories according to the international standards EN 50393, IEC 60502-4, IEC 61442 and HD 629. ISO 9001 Certificate Since 1992, Euromold s commitment to quality is demonstrated by its ISO 9001 certification. While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as standards and technology evolve.

SEPARABLE CONNECTORS AND BUSHINGS INTERFACE E - 5/8" TABLE OF CONTENTS 784TB - tee connector 800PB-58 - coupling connector 804PB-58 - coupling connector 800SA-58 - surge arrester 750S1, 775S1 & 775T1 - equipment bushing Accessories Possible arrangements INTERFACE E - 5/8" Dimensions according to IEEE std. 386 (in mm, except where noted). Dia. 61.5 ±0.2 Dia. 39.9 ±0.2 Dia. 32 nominal 5/8"-11UNC-2B 0 1.5-0.5 25.4 min 31.75 ±0.4 3.7 ±0.2 14.8 min Dia. 76.2 ±0.2 In mm. 2 09/2017

CONNECTING POSSIBILITIES BUSHINGS / ACCESSORIES CONNECTION CONNECTORS / ACCESSORIES Equipment interface dead-ending of equipment 750BE or 775BE Bushing extender 750DP or 775DP Dead-end plug 750S1 or 775S1 Equipment bushing 750BE or 775BE Bushing extender 750CP or 775CP Connecting plug connector standing away from equipment one cable to 775T1 Equipment bushing equipment (K)(M)(P)800PB-58 Coupling connector in-line junction 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug dead-ending of connector (K)(M)(P)784TB/G Tee connector (K)(M)(P)804PB-58 Coupling connector 750SOP Stand-off plug cable isolation 800SA-58 Surge arrester cable earthing 750GP Earthing plug 3 09/2017

784TB FOR USE WITH BUSHINGS WITH ALUMINIUM CONTACT ROD INTERFACE E - 5/8" TEE CONNECTOR APPLICATION Separable tee shape connector (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors,...). Also connects cable to cable when using the appropriate mating parts. TECHNICAL CHARACTERISTICS The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory. DESIGN Separable connector comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type E 5/8" interface as described by IEEE 386. 5. Conductor contact. 6. Basic insulating plug 858 BIPA (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Stud/nut/washer 5/8".. Earthing lead. 360 mm 4 9 5 1 2 3 205 mm 8 6 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv 20.8/36 (42) kv Up to 42 kv Up to 800 A The screen break design enables cable outer sheath testing without removing or dismantling the connector. 7 SPECIFICATIONS AND STANDARDS The 784TB separable connector meets the requirements of CENELEC HD 629.1. Separable connector type 784TB/G K784TB/G M784TB/G P784TB/G Voltage Um (kv) 12 24 36 42 Current Ir (A) When installed on an appropriate equipment bushing 800 800 800 800 Conductor sizes (mm 2 ) min 50 35 35 35 max 09/2017 4

KIT CONTENTS The complete (K)(M)(P)784TB/G tee connector kit comprises 3x the following components: The kit also comprises silicone grease, field control mastic, gloves, wipers, roll adhesive tape, installation instructions, venting rod and crimp chart. Conductor contact TMBC-X 3 x (K)(M)(P)784TB/G- S-W-X connector kit Connector housing (K)(M)(P)784BT/G Stud+nut 5/8" +washer Conductor contact TBC-X Basic insulating plug (K)(M)(P)858BIPA + rubber cap Cable reducer 611CA-W ORDERING INSTRUCTIONS To order the tee connector, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv, add an 'M' for use up to 36 kv, add a 'P' for use up to 42 kv. TABLE W Ordering part number 3 x 784TB/G-S-15-X 3 x 784TB/G-S-19-X 3 x 784TB/G-S-22-X 3 x 784TB/G-S-27-X 3 x 784TB/G-S-32-X 3 x 784TB/G-S-37-X 3 x 784TB/G-S-43-X Dia. over core insulation (mm) min 16.0 20.0 23.5 28.5 34.0 39.0 45.5 max 22.0 26.5 31.0 37.5 42.5 48.5 56.0 EXAMPLE: The copper wire screened cable is 36 kv, 240 mm 2 stranded aluminium with a diameter over core insulation of 37.0 mm. Order 3 x M784TB/G-S-32-240AL2. TABLE X Conductor sizes (mm 2 ) 35 50 70 95 120 150 185 240 300 400 500 Aluminium conductor DIN hexagonal 35AL2 50AL2 70AL2 95AL2 120AL2 150AL2 185AL2 240AL2 300AL2 400AL2 500AL2 AL2 Deep indent 35AL1 50AL1 70AL1 95AL1 120AL1 150AL1 185AL1 240AL1 300AL1 400AL1 500AL1 AL1 16.95UN5 Aluminium and copper conductor 50.150UN5 Bolted 95.240UN5 120.300UN5 185.400UN5 400.UN5 Copper conductor DIN hexagonal 35UN2 50UN2 70UN2 95UN2 120UN2 150UN2 185UN2 240UN2 300UN2 400UN2 500UN2 UN2 For use with copper tape screened cables. Order: Kit MT. For use in potentially explosive atmospheres (for 12 kv max.). Order: -/ATEX. For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. Components can be ordered individually. Multiple cable arrangement possible. Please contact our representative. 5

784TB FOR USE WITH BUSHINGS WITH COPPER CONTACT ROD INTERFACE E - 5/8" TEE CONNECTOR APPLICATION Separable tee shape connector (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors,...). Also connects cable to cable when using the appropriate mating parts. TECHNICAL CHARACTERISTICS The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory. DESIGN Separable connector comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type E 5/8" interface as described by IEEE 386. 5. Conductor contact. 6. Basic insulating plug 858 BIPA (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Stud/nut/washer 5/8".. Earthing lead. 360 mm 4 9 5 1 2 3 205 mm 8 6 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv 20.8/36 (42) kv Up to 42 kv Up to 1250 A The screen break design enables cable outer sheath testing without removing or dismantling the connector. 7 SPECIFICATIONS AND STANDARDS The 784TB separable connector meets the requirements of CENELEC HD 629.1. Separable connector type 784TB/G K784TB/G M784TB/G P784TB/G Voltage Um (kv) 12 24 36 42 Current Ir (A) When installed on an appropriate equipment bushing 1250 1250 1250 1250 Conductor sizes (mm 2 ) min 50 35 35 35 max 09/2017 6

KIT CONTENTS The complete (K)(M)(P)784TB/G tee connector kit comprises 3x the following components: The kit also comprises silicone grease, field control mastic, gloves, wipers, roll adhesive tape, installation instructions, venting rod and crimp chart. Conductor contact TMBC-X 3 x (K)(M)(P)784TB/G- S-W-X connector kit Connector housing (K)(M)(P)784BT/G Stud+nut 5/8" +washer Conductor contact TBC-X Basic insulating plug (K)(M)(P)858BIPA + rubber cap Cable reducer 611CA-W ORDERING INSTRUCTIONS To order the tee connector, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv, add an 'M' for use up to 36 kv, add a 'P' for use up to 42 kv. TABLE W Ordering part number 3 x 784TB/G-S-15-X 3 x 784TB/G-S-19-X 3 x 784TB/G-S-22-X 3 x 784TB/G-S-27-X 3 x 784TB/G-S-32-X 3 x 784TB/G-S-37-X 3 x 784TB/G-S-43-X Dia. over core insulation (mm) min 16.0 20.0 23.5 28.5 34.0 39.0 45.5 max 22.0 26.5 31.0 37.5 42.5 48.5 56.0 EXAMPLE: The copper wire screened cable is 36 kv, 240 mm 2 stranded aluminium with a diameter over core insulation of 37.0 mm. Order 3 x M784TB/G-S-32-240(K)MBI2. TABLE X Conductor sizes (mm 2 ) 35 50 70 95 120 150 185 240 300 400 500 Aluminium conductor DIN hexagonal 35BI2 50BI2 70BI2 95BI2 120BI2 150BI2 185BI2 240BI2 300BI2 400BI2 500BI2 - Deep indent 35BI1 50BI1 70BI1 95BI1 120BI1 150BI1 185BI1 240BI1 300BI1 400BI1 500BI1 BI1 16.95UN5 Aluminium and copper conductor 50.150UN5 Bolted 95.240UN5 120.300UN5 185.400UN5 400.UN5 Copper conductor DIN hexagonal 35CU2 50CU2 70CU2 95CU2 120CU2 150CU2 185CU2 240CU2 300CU2 400CU2 500CU2 CU2 For use with copper tape screened cables. Order: Kit MT. For use in potentially explosive atmospheres (for 12 kv max.). Order: -/ATEX. For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. Components can be ordered individually. Multiple cable arrangement possible. Please contact our representative. 7

800PB-58 INTERFACE E - 5/8" COUPLING CONNECTOR FOR 784TB/G APPLICATION Separable coupling connector (bolted type) for dual cable arrangement. It has been designed to be used with 784TB separable tee connector. TECHNICAL CHARACTERISTICS A thick conductive EPDM jacket provides a total safe to touch screen. Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory. DESIGN 1. Interface designed to fit 784TB connector. 2. Contact rod type 5/8". 3. Conductor connector (hexagonal crimping, deep indent crimping or bolted). 4. Conductive EPDM insert. 5. Conductive EPDM jacket. 6. Insulating EPDM layer moulded between the insert and the jacket. 7. Cable reducer. 8. Conductive EPDM cap. 9. Basic insulating plug 858BIPA (with VD point).. Earthing lead. 1 360 mm 784TB connector 3 mm 2 3 4 6 5 7 8 9 800PB-58 coupling connector 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv 20.8/36 (42) kv Up to 42 kv 1250 A The screen break design enables cable outer sheath testing without removing or dismantling the connector. 1 mm SPECIFICATIONS AND STANDARDS The 800PB-58 coupling connector meets the requirements of CENELEC HD 629.1. Separable connector type 800PB-58/G K800PB-58/G M800PB-58/G P800PB-58/G Voltage Um (kv) 12 24 36 42 Current Ir (A) 1250 1250 1250 1250 Conductor sizes (mm 2 ) min 35 35 50 50 max 300 300 240 240 09/2017 8

KIT CONTENTS The complete (K)(M)(P) 800PB- 58/G coupling connector kit comprises 3 x the following components: The kit also comprises silicone grease, field control mastic, installation rod, gloves, wipers, roll adhesive tape, installation instructions and crimp chart. Conductor contact TMBC-X Cable reducer 430CA-W 3 x (K)(M)(P)800PB-58/G-S- W-X coupling connector kit Connector housing (K)(M)(P)800BP/G Contact rod 5/8" and stud 5/8" Conductor contact TBC-X ORDERING INSTRUCTIONS To order the coupling connector, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv, add an 'M' for use up to 36 kv, add a 'P' for use up to 42 kv. TABLE W TABLE X Ordering part number 3 x 800PB-58/G-S-11-X 3 x 800PB-58/G-S-16-X 3 x 800PB-58/G-S-18-X 3 x 800PB-58/G-S-27-X 3 x 800PB-58/G-S-30-X* * will include an adapted installation instruction Dia. over core insulation (mm) min 12.0 17.0 19.0 28.5 34.5 max 17.5 23.5 32.6 37.5 40.5 EXAMPLE: The cable is 24 kv, 150 mm 2 compact stranded copper with a diameter over core insulation of 27.5 mm. Order 3 x K800PB-58/G-S-18-95.240UN5 coupling connector kit. Conductor sizes (mm 2 ) Aluminium conductor DIN hexagonal Deep indent Aluminium and copper conductor Bolted Copper conductor DIN hexagonal 35 35BI2 35BI1 35CU2 50 50BI2 50BI1 50CU2 70 70BI2 70BI1 70CU2 95 95BI2 95BI1 95CU2 120 120BI2 120BI1 120CU2 150 150BI2 150BI1 150CU2 185 185BI2 185BI1 185CU2 240 240BI2 240BI1 240CU2 300 300BI2 300CU2 16.95UN5 50.150UN5 95.240UN5 120.300UN5 For use with copper tape screened cables. Order: Kit MT. For use with copper wire screened cables. No earthing device is necessary. For use with other cable types. Please contact our representative. For outdoor applications. Order: +MWS. For use in potentially explosive atmospheres (for 12 kv max). Add -/ATEX to part number. 9

804PB-58 INTERFACE E - 5/8" COUPLING CONNECTOR FOR 784TB/G APPLICATION Separable coupling connector for dual cable arrangement. It has been designed to be used with 784TB separable tee connectors. TECHNICAL CHARACTERISTICS A thick conductive EPDM jacket provides a total safe to touch screen. Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory. DESIGN 1. Interface designed to fit 784TB connector. 2. Contact rod type 5/8". 3. Conductor connector (hexagonal crimping, deep indent crimping or bolted). 4. Conductive EPDM insert. 5. Conductive EPDM jacket. 6. Insulating EPDM layer moulded between the insert and the jacket. 7. Cable reducer. 8. Conductive EPDM cap. 9. Basic insulating plug 858BIPA (with VD point).. Earthing lead. 360 mm 1 784TB connector 290 mm 2 3 4 5 6 7 8 9 800PB-58 coupling connector 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv 20.8/36 (42) kv Up to 42 kv 1250 A The screen break design enables cable outer sheath testing without removing or dismantling the connector. 1 mm SPECIFICATIONS AND STANDARDS The 804PB-58 coupling connector meets the requirements of CENELEC HD 629.1. Separable connector type 804PB-58/G K804PB-58/G M804PB-58/G P804PB-58/G Voltage Um (kv) 12 24 36 42 Current Ir (A) 1250 1250 1250 1250 Conductor sizes (mm 2 ) min 50 35 35 35 max 09/2017

KIT CONTENTS The complete (K)(M)(P)804PB- S-58/G coupling connector kit comprises 3 x the following components: The kit also comprises silicone grease, field control mastic, gloves, wipers, roll adhesive tape, installation instructions and crimp chart. Conductor contact TMBC-X 3 x (K)(M)(P)804PB-58/G- S-W-X coupling connector kit Connector housing (K)(M)(P)804BP/G Contact rod 5/8" and stud 5/8" Conductor contact TBC-X Cable reducer 611CA-W ORDERING INSTRUCTIONS To order the coupling connector, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv, add an 'M' for use up to 36 kv, add a 'P' for use up to 42 kv. TABLE W TABLE X Ordering part number 3 x 804PB-58/G-S-15-X 3 x 804PB-58/G-S-19-X 3 x 804PB-58/G-S-22-X 3 x 804PB-58/G-S-27-X 3 x 804PB-58/G-S-32-X 3 x 804PB-58/G-S-37-X 3 x 804PB-58/G-S-43-X Dia. over core insulation (mm) min 16.0 20.0 23.5 28.5 34.0 39.0 45.5 max 22.0 26.5 31.0 37.5 42.5 48.5 56.0 Example: The copper wire screened cable is 36 kv, 240 mm 2 stranded aluminium with a diameter over core insulation of 37.0 mm. Order 3 x M804PB-58/G-S-32-240BI2 coupling connector kit. Conductor sizes (mm 2 ) 35 50 70 95 120 150 185 240 300 400 500 Aluminium conductor DIN hexagonal 35BI2 50BI2 70BI2 95BI2 120BI2 150BI2 185BI2 240BI2 300BI2 400BI2 500BI2 Deep indent 35BI1 50BI1 70BI1 95BI1 120BI1 150BI1 185BI1 240BI1 300BI1 400BI1 500BI1 BI1 16.95UN5 Aluminium and copper conductor 50.150UN5 Bolted 95.240UN5 120.300UN5 185.400UN5 400.UN5 Copper conductor DIN hexagonal 35CU2 50CU2 70CU2 95CU2 120CU2 150CU2 185CU2 240CU2 300CU2 400CU2 500CU2 CU2 For use with copper tape screened cables. Order: Kit MT. For use with copper wire screened cables. No earthing device is necessary. For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. Components can be ordered individually. For use in potentially explosive atmospheres (for 12 kv max). Add -/ATEX to part number. 11

800SA-58 INTERFACE E - 5/8" SURGE ARRESTOR FOR 784TB/G APPLICATION Surge arrester designed to protect 12, 24, 36 and 42 kv class components, including transformers, equipment, cable and accessories from high voltage surges resulting from lightning or switching. It has been designed to be used with the 784TB separable tee connectors. TECHNICAL CHARACTERISTICS This surge arrester is a metal oxide varistor surge arrester in an elbow configuration. Each arrester is tested for AC withstand, partial discharge and critical voltage prior to leaving the factory. DESIGN Surge arrester comprising: 1. Interface designed to fit the 784TB tee connector. 2. Conductive EPDM insert. 3. Conductive EPDM jacket. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Receptacle for contact rod. 6. Metal oxide valve elements. 7. Steel cap. 8. Earth connection. 9. Earth lead. SPECIFICATIONS AND STANDARDS The 800SA-58 surge arresters meet the test requirements of IEC 60099-4. L2 1 5 2 7 8 170 mm 5 mm Dia. 75 mm 3 L1 9 4 6 Dia. 65 mm Surge arrester type Nominal discharge current In (ka) Rated voltage Ur (kv) Max. continuous operating voltage Uc (kv) Dimensions (mm) L1 L2 800SA-58--6N 800SA-58--9N 800SA-58--12N 800SA-58--15N 800SA-58--18N 800SA-58--22N 800SA-58--24N 800SA-58--30N 800SA-58--33N 800SA-58--36N 800SA-58--45N 800SA-58--51N 6 9 12 15 18 22 24 30 33 36 45 51 4.8 7.2 9.6 12.0 14.4 17.6 19.2 24.0 26.4 28.8 36.0 40.8 270 270 270 270 270 270 370 370 370 370 470 470 3 3 3 3 3 3 4 4 4 4 5 5 09/2017 12

TYPICAL APPLICATION AND DIMENSIONS 290 mm 180 mm 1 mm ORDERING INSTRUCTIONS To order the surge arrester, specify the surge arrester type, as described on previous page. EXAMPLE: For a maximum continuous operating voltage (r.m.s.) of 24 kv and a nominal discharge current of ka. Order a 800SA-58--30N surge arrester. Type 784TB tee connector Type 800SA-58 surge arrester NOTE: the surge arrester body needs to be positioned vertically after installation. For use in potentially explosive atmospheres (for 12 kv max). Add -/ATEX to part number. TECHNICAL DATA Surge arrester type Steep current residual voltage @ ka [1/20 µs] (kv) Lightning current residual voltage [8/20 µs] (kv) Switching impulse residual voltage [36/90 µs] (kv) @ 5 ka @ ka @ 20 ka @ 125 A @ 500 A High current impulse withstand (ka) 800SA-58--6N 800SA-58--9N 800SA-58--12N 800SA-58--15N 800SA-58--18N 800SA-58--22N 800SA-58--24N 800SA-58--30N 800SA-58--33N 800SA-58--36N 800SA-58--45N 800SA-58--51N 20.4 28.5 38.0 48.1 58.1 70.1 77.0 97.0 3.4 115.9 144.1 166.0 16.8 23.5 31.4 39.7 48.0 57.9 63.6 80.1 85.4 95.7 119.0 137.1 18.3 25.6 34.2 43.2 52.2 63.0 69.2 87.2 93.0 4.2 129.5 149.2 20.5 28.7 38.3 48.4 58.5 70.6 77.6 97.7 4.2 116.8 145.1 167.2 12.9 18.0 24.1 30.5 36.8 44.4 48.8 61.5 65.6 73.5 91.3 5.2 13.7 19.2 25.7 32.5 39.2 47.3 52.0 65.5 69.9 78.3 97.3 112.1 0 0 0 0 0 0 0 0 0 0 0 0 13

750S1, 775S1 & 775T1 INTERFACE E - 5/8" EQUIPMENT BUSHING APPLICATION For use in equipment insulated with oil fluid, typically for transformers, switchgear, capacitors... TECHNICAL CHARACTERISTICS Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. DESIGN The equipment bushing is a moulded epoxy insulated part in accordance with ANSI/IEEE 386 std. (5/8" threading system). 5/8-11UNC-2B stainless steel flange 1.5 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv SPECIFICATIONS AND STANDARDS The bolted type equipment bushings 750S1, 775S1 and 775T1 meet the requirements of IEC 60137. Minimum oil level: 75 mm Dia. 32 A B Up to 36 kv 800 A & 1250 A 32 ORDERING INSTRUCTIONS To order the equipment bushing, specify the type. Dia. 76 Dia. 114 5/8-11UNC-2A In mm. Equipment bushing type Voltage Ur (kv) Current Ir (A) Dimensions (mm) A B 750S1 775S1 775T1 36 36 36 800 1250 1250 75 75 221 235 235 378 09/2017 14

FIXINGS FOR EQUIPMENT BUSHINGS 750S1, 775S1 AND 775T1 BUSHINGS BUSHING FIXING FLANGE To order the bushing fixing flange, simply specify MK600-1. bushing interface fixing studs and nuts M fixing flange type : MK 600-1 (antimagnetic) equipment sealing gasket equipment connection 140 60 60 170 In mm. 15

ACCESSORIES APPLICATION For use with connectors and bushings with an INTERFACE E - 5/8" as described in IEEE std. 386. TECHNICAL CHARACTERISTICS All these products, except the earthing plug, are tested for AC withstand and partial discharge prior to leaving the factory. 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv Up to 36 kv 750CP & 775CP CONNECTING PLUG For connecting two or more connectors with a type E - 5/8" interface together, thus creating a separable cable joint or a multiple cable connection to equipment. ORDERING INSTRUCTIONS Order 750CP for 800 A or 775CP for 1250 A applications. 750BE & 775BE BUSHING EXTENDER Provides an extension piece to allow cables to stand away from equipment. Is used in conjunction with the connecting plug (750CP or 775CP). ORDERING INSTRUCTIONS Order 750BE for 800 A or 775BE for 1250 A applications. 750SOP STAND-OFF PLUG Is designed to support and 'deadend' connectors with a type E - 5/8" interface when removed from equipment. ORDERING INSTRUCTIONS Order 750SOP for 800 A and 1250 A applications. 09/2017 16

750GP EARTHING PLUG Is designed to support and earth connectors with a type E - 5/8" interface when removed from equipment. ORDERING INSTRUCTIONS Order 750GP for 800 A and 1250 A applications. KIT MT EARTHING KIT FOR COPPER TAPE SCREENED CABLES Contains a tinned copper braid (25 mm² - L = 500 mm), a tinned copper wire for cleating and water sealing mastic. ORDERING INSTRUCTIONS Order Kit MT for 800 A and 1250 A applications. 17

POSSIBLE ARRANGEMENTS 784TB Single cable arrangement. Order 784TB for 12 kv, K784TB for 24 kv, M784TB for 36 kv or P784TB for 42 kv applications. 195 784TB+800PB-58 Dual cable arrangement. Order 784TB+800PB-58 for 12 kv, K784TB+K800PB-58 for 24 kv, M784TB+M800PB-58 for 36 kv or P784TB+P800PB-58 for 42 kv applications. 300 858BIPA basic insulating plug 858BIPA basic insulating plug 800PB-58 coupling connector 784TB tee connector 784TB tee connector 125 125 5 750BE+784TB Connector standing away from equipment. Order 750BE+784TB for 12 kv, K750BE+K784TB for 24 kv or M750BE+M784TB for 36 kv applications. 475 784TB+800SA-58 Dead-ending. Order 784TB+800PB-58 for 12 kv, K784TB+K800SA-58 for 24 kv, M784TB+M800SA-58 for 36 kv or P784TB+P800SA-58 for 42 kv applications. 300 750BE bushing extender connecting plug 750CP or 775CP 784TB tee connector 405 In mm. 125 09/2017 18

CONNECTOR ON STAND- OFF PLUG Order 750SOP for 12 kv, K750SOP for 24 kv or M750SOP for 36 kv applications. CONNECTOR ON EARTHING PLUG Order 750GP for 12 kv, 24 kv or 36 kv applications. 750SOP stand-off plug 750GP earthing plug In mm. 19

NOTES 09/2017 20

21 09/2017

Nexans Network Solutions N.V. - Div. Euromold Zuid III, Industrielaan 12, B-9320 Erembodegem Tel.: +32(0)53 85 02 11 sales.euromold@nexans.com www.euromold.be Catalogue also available on Website and Mobile Apps Find out more about Nexans Power Accessories. 09/2017