a Nexans company Catalogue 2012

Similar documents
Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2006

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2007

a Nexans company Catalogue 2011

a Nexans company Medium voltage symmetrical separable connectors - Interface C -

a Nexans company Catalogue 2015

a Nexans company Catalogue 2009

THORNE & DERRICK UK TEL FAX TEL FAX

THORNE & DERRICK UK TEL FAX TEL FAX

a Nexans company Catalogue 2009

a Nexans company Catalogue 2007

a Nexans company Catalogue 2009

INTERFACE C MEDIUM VOLTAGE SYMMETRICAL SEPARABLE CONNECTORS CATALOGUE 2017

INTERFACE F MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

INTERFACE A MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

Nexans Network Solutions Div. Euromold

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2008

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

a Nexans company Catalogue 2015

Power cables accessories for use in potentially explosive atmospheres

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2008

ACCESSORIES. Application For use with connectors and bushings with an interface C as described by CENELEC EN and

global leader in cables

(K),(M),(P)489TB/G Up to 42 kv

(K),(M)430TB/G Up to 36 kv

a Nexans company Catalogue 2012

High Voltage Accessories up to 72.5 kv

Shielded surge arresters

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

Cold-shrinkable Silicone 12 kv - 24 kv - 36 kv

power cable accessories

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )


INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Medium Voltage. Joints & Terminations

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

ELASTIMOLD UNDERGROUND CABLE ACCESSORIES

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

H e a t s h r i n k P r o d u c t G u i d e

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

IEC Separable Connectors 17.5 kv/24 kv, 630A

Power cable accessories catalogue

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Nexans Switzerland. Global expert in cables and cabling system. Cossonay Production Plant

Completing the picture

600 A 15 kv class T-OP II deadbreak connector

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

3 TM Cold Applied Barrier Boot System

Nexans WINDLINK connection system. Nexans Power Accessories Germany GmbH

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

TE S RAYCHEM RSTI-CC-58 SCREENED, SEPARABLE COUPLING SYSTEM

Separable Connectors and Kits

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

Energy Division. PCA Single Column Polymeric Surge Arrester

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

Loadbreak Apparatus Connectors

Installation Instruction Heatshrink Termination For 3 Core Polymeric Cables 7.2kV to 36kV

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

INSTALLATION PRODUCTION TESTS

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

600 A 35 kv class BT-TAP deadbreak connector

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

Cellplux Plug-in Technology

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

(BUSINESS DAYS) 200A Separable Connectors

Cable category. B Multi-core cables for domestic/handheld equipment Rubber insulation PVC insulation TPE insulation 0.

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

Ethernet Buccaneer BUCCANEER DATA. bulgin

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

MMC RTX series EN3716

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

ABG Cable Glands Installation Procedure

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

IS90750-ENG - 430TB/G-45/LCA 14 January 201 O - Revision 7 - Supersedes edition of 25 June 2009 Page 1 of 9

Gas Insulated Switchgear

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

ELB ELB

General characteristics and technical data Series MCS

Transformer bushings, type GSA-OA Technical guide

ENERGIE - KABELGARNITUREN ACCESSOIRES POUR CÂBLES D ÉNERGIE

Installation Instructions

Transformer bushings, type GOH. Technical guide

It s time to get connected with

CATALOG. Underground cable accessories

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

CP Automatic capacitor bank

Air-insulated switchgear UniGear type ZS1

CLICK-FIT. High Voltage Accessories for Extruded Cables

Transcription:

a Nexans company Catalogue 2012

Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: premoulded EPDM rubber connectors for cables and epoxy bushings for transformers and switchgear, as well as a large range of coldshrinkable terminations and joints from 12 to 42 kv. Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group. ISO 9001 Certificate Since 1992, Euromold s commitment to quality is demonstrated by its ISO 9001 certification. International standards All our products meet the International standards like CENELEC HD 629.1, CENELEC EN 50180, IEC 60137, IEC 60502-4 or country specifications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are continuously performed in our test fields. Laboratory accreditation Since June 2000, Euromold s independent ELAB laboratory obtained the BELAC accreditation no.144-test conform with the European standards for laboratories ISO 17025 for electrical testing of low and medium voltage cable accessories according to the international standards EN 50393, IEC 60502-4, IEC 61442 and HD 629. 04/2012 While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as standards and technology evolve. 1

SEPARABLE CONNECTORS AND BUSHINGS INTERFACE B Table of contents LR - elbow connector TE - tee connector T1 - equipment bushing AR-1 - equipment bushing AR-2 - equipment bushing AR-8 - equipment bushing SFR-P - equipment bushing Accessories Possible arrangements Interface B Dimensions according to European CENELEC EN 50180 and 50181 (in mm). Dia. 56 ±0.2 Dia. 46 ±0.2 Dia. for pin 14 0-0.04 40 min 90 ±0.2 11 min Dia. 70 ±0.2 04/2012 2

Connecting possibilities BUSHINGS / ACCESSORIES CONNECTION CONNECTORS / ACCESSORIES Equipment interface dead-ending of equipment (K)(M)DR Dead-end receptacle (K)(M)T1 Equipment bushing (K)(M)AR-1 Equipment bushing one cable to equipment (K)(M)LR/G Elbow connector (K)(M)AR-2 Equipment bushing (K)(M)AR-8 Equipment bushing (K)(M)TE/G Tee connector (K)SFR-P Equipment bushing two cables to equipment (K)(M)SOP Stand-off plug cable isolation tap-off 630/250A (K)RTPA Reducing tap plug GP Earthing plug cable earthing in-line junction (K)(M)CP-SC Connecting plug 04/2012 3

LR INTERFACE B ELBOW CONNECTOR Application Separable elbow connector (plug-in type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors...). Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory. Up to 36 kv - A 6/10 (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv Design Separable connector comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type B - A interface as described by CENELEC EN 50180 and 50181. 5. Conductor connector. 6. Cable reducer. 7. Earthing lead. The screen break design enables cable outer sheath testing without removing or dismantling the connector. 365 mm 4 5 1 2 3 210 mm Specifications and standards The separable connector LR meets the requirements of CENELEC HD 629.1. 7 6 Separable connector type Voltage Um (kv) Current Ir (A) Conductor sizes (mm 2 ) min max LR/G KLR/G MLR/G 12 24 36 50 25 35 240 240 185 04/2012 4

Kit contents The complete (K)(M)LR/G elbow connector kit comprises the following components: The kit also comprises lubricant, wipers, installation instructions and crimp chart. (K)(M)LR/G-W-X connector kit Connector housing (K)(M)BLR/G Pin contact + hex. key LRF Conductor contact LRC-X Bail restraint BA Cable reducer 411CA-W Ordering instructions Select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type. Add a 'K' for use up to 24 kv and add an 'M' for use up to 36 kv. Table W Ordering part number LR/G-11-X LR/G-15-X LR/G-19-X LR/G-22-X LR/G-25-X LR/G-27-X Dia. over core insulation (mm) min max 12.0 17.5 16.0 22.0 20.0 26.5 23.5 31.0 26.5 32.5 28.5 37.5 Table X Conductor sizes (mm²) Aluminium Copper DIN hexagonal Deep indent DIN hexagonal Example: The copper wire screened cable is 12 kv, 150 mm 2 stranded copper with a diameter over core insulation of 23.5 mm. Order a LR/G-19-150(K)M- 11-2 elbow connector kit. 25 35 50 70 95 120 150 185 240-35(K)M-12-2 50(K)M-12-2 70(K)M-12-2 95(K)M-12-2 120(K)M-12-2 150(K)M-12-2 185(K)M-12-2 240(K)M-12-2 - 35KM-12-1 50(K)M-12-1 70(K)M-12-1 95(K)M-12-1 120(K)M-12-1 150(K)M-12-1 185(K)M-12-1 240(K)M-12-1 25(K)M-11-2 35(K)M-11-2 50(K)M-11-2 70(K)M-11-2 95(K)M-11-2 120(K)M-11-2 150(K)M-11-2 185(K)M-11-2 240(K)M-11-2 For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-226 cables. Please contact our representative. For use with fabric tape (graphite) screened cables. Order additional semi-conductive tape (type TSC). For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. Components can be ordered individually. 5

Application Separable tee connector (plugin type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors...). Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory. TE INTERFACE B TEE CONNECTOR Up to 36 kv - A 6/10 (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv Design Separable connector comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type B - A interface as described by CENELEC EN 50180 and 50181. 5. Conductor connector. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Clamping pin contact. 10. Bail restraint. 11. Earthing lead. 390 mm 4 9 5 1 2 3 255 mm 220 mm 10 6 8 The screen break design enables cable outer sheath testing without removing or dismantling the connector. 11 Specifications and standards The separable connector TE meets the requirements of CENELEC HD 629.1. 7 Separable connector type Voltage Um (kv) Current Ir (A) Conductor sizes (mm 2 ) min max TE/G KTE/G MTE/G 12 24 36 70 25 35 240 240 185 04/2012 6

Kit contents The complete (K)(M)TE/G elbow connector kit comprises the following components: The kit also comprises lubricant, wipers, installation instructions and crimp chart. (K)(M)TE/G-W-X connector kit Connector housing (K)(M)BT/G Clamping pin contact TEF Conductor contact TEC-X Basic insulating plug + rubber cap (K)(M)BIPA Bail restraint T-BA Cable reducer 411CA-W Ordering instructions Select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type. Add a 'K' for use up to 24 kv and add an 'M' for use up to 36 kv. Table W Ordering part number TE/G-11-X TE/G-15-X TE/G-19-X TE/G-22-X TE/G-25-X TE/G-27-X Dia. over core insulation (mm) min max 12.0 17.5 16.0 22.0 20.0 26.5 23.5 31.0 26.5 32.5 28.5 37.5 Table X Example: The copper wire screened cable is 24 kv, 240 mm 2 stranded aluminium with a diameter over core insulation of 32.1 mm. Order 3 x KTE/G-27-240(K)M-12-2 tee connector kit. Conductor sizes (mm²) 25 35 50 70 95 120 150 185 240 Aluminium Copper DIN hexagonal Deep indent DIN hexagonal - - 25(K)M-11-2 35(K)M-12-2 35KM-12-1 35(K)M-11-2 50(K)M-12-2 50(K)M-12-1 50(K)M-11-2 70(K)M-12-2 70(K)M-12-1 70(K)M-11-2 95(K)M-12-2 95(K)M-12-1 95(K)M-11-2 120(K)M-12-2 120(K)M-12-1 120(K)M-11-2 150(K)M-12-2 150(K)M-12-1 150(K)M-11-2 185(K)M-12-2 185(K)M-12-1 185(K)M-11-2 240(K)M-12-2 240(K)M-12-1 240(K)M-11-2 For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-226 cables. Please contact our representative. For use with fabric tape (graphite) screened cables. Order additional semi-conductive tape (type TSC). For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. Components can be ordered individually. 7

T1 /AR-1 /AR-2 INTERFACE B EQUIPMENT BUSHINGS Application For use in equipment insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. Up to 36 kv - A 6/10 (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv Specifications and standards The plug-in type equipment bushings are moulded epoxy insulated parts and meet the requirements of IEC 60137. The (K)(M)T1 also meets CENELEC EN 50180. C 10 133 Ordering instructions To order the equipment bushing, specify the type. The bushings are supplied with an earth jumper (/J) or an earth plate (/GS). This earth connection must be specified when ordering. E.g. KAR-1/J. Minimum oil level: - 12 kv: 40 mm - 24 kv: 50 mm - 36 kv: 75 mm Dia. H B A E Dia. 70 Dia. F Dia. G D In mm. Equipment bushing type Voltage Ur (kv) Current Ir (A) Dimensions (mm) A B C D E Dia. F Dia. G Dia. H T1 KT1 MT1 AR-1 KAR-1 MAR-1 AR-2 KAR-2 MAR-2 12 24 36 12 24 36 12 24 36 310 310 310 380 380 380 329 329 329 144 144 144 213 213 213 138 138 138 30 30 30 30 30 30 36 36 36 M12 M12 M12 M12 M12 M12 M16 M16 M16 22 22 22 22 22 22 40 40 40 88 88 88 74 74 74 100 100 100 128 128 128 128 128 128 150 150 150 16 16 16 16 16 16 30 30 30 04/2012 8

AR-2/GS Bushing AR-2/J Bushing FIXINGS FOR EQUIPMENT BUSHINGS AR-1/J and T1/J Bushings bushing interface fixing studs bushing interface fixing studs fixing flange fixing flange B DIN 42 538 NF C 52-053 claw clamp F DIN 42 538 stud clamp E DIN 42 538 stud clamp equipment sealing gasket equipment sealing gasket equipment connection equipment connection tabs for the bail restraint tabs for the bail restraint earth plate earth jumper earth jumper Bushing clamping kit To order the bushing clamping kit, according to NFC 52-053 standards, simply specify KBCNF- (for bushing type AR-2). Contents: - 4 x claw clamp NF - 1 x sealing gasket. Bushing clamping kit To order the bushing clamping kit, simply specify: KBCDS- B. Contents: - 1 x fixing flange - 6 x stud clamp F - 1 x sealing gasket. Bushing clamping kit To order the bushing clamping kit, according to DIN 42 538 standards, simply specify KBCD-B. Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket. Fixing dimensions standards NF C 52-053 French standards. Fixing dimensions Fixing dimensions standards DIN 42 538 German standards. M10 or M12 M12 M10 50 to 70 25 60 30 55 30 4 fixing studs Dia. 105 Dia. 171 6 fixing studs Dia. 105 Dia. 171 6 fixing studs Dia. 90 Dia. 140 In mm. 9

Application For use in equipment insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. AR-8 INTERFACE B EQUIPMENT BUSHING Up to 36 kv - 250 A 6/10 (12) kv 6,35/11 (12) kv 8,7/15 (17,5) kv 12/20 (24) kv 12,7/22 (24) kv 18/30 (36) kv Specifications and standards The plug-in type equipment bushings AR-8 are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180 and IEC 60137. Ordering instructions To order the equipment bushing, specify the type. The bushings can be supplied with an earth jumper (/J). E.g. MAR-8/J. Minimum oil level: - 12 kv: 40 mm - 24 kv: 50 mm - 36 kv: 75 mm Dia. 20 8.5 28 80 231.5 20 M10 Dia. 74 Dia. 110 In mm. Equipment bushing type Voltage Ur (kv) Current Ir (A) AR-8 KAR-8 MAR-8 12 24 36 250 250 250 04/2012 10

AR-8/J Bushing bushing interface 4 x fixing stud M10 FIXINGS FOR EQUIPMENT BUSHINGS Bushing clamping kit To order the bushing clamping kit, according to DIN 42 538 standards, simply specify: KBCD-200. Contents: - 1 x fixing flange A - 4 x stud clamp E - 1 x sealing gasket. A DIN 42 538 fixing flange E DIN 42 538 stud clamp equipment sealing gasket equipment connection Fixing dimensions standards DIN 42 538 German standards. tabs for the bail restraint M10 25 55 earth jumper 4 fixing studs Dia. 78 Dia. 123 In mm. 11

Application For use in equipment insulated with SF 6 gas. Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. SFR-P INTERFACE B EQUIPMENT BUSHING Up to 24 kv - A 6/10 (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv Design The equipment bushing is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN 50180. The SFR-P bushing has a shank outside this standard, adapted for use in SF 6 gas. Dia. 70 218 Specifications and standards The plug-in type equipment bushing SFR-P meets the requirements of CENELEC EN 50180 and IEC 60137. 33 Ordering instructions To order the equipment bushing, simply specify the type. 95 Dia. 25 Dia. 70 Dia. 109 M12 In mm. Equipment bushing type Voltage Ur (kv) Current Ir (A) SFR-P KSFR-P 12 24 04/2012 12

FIXINGS FOR EQUIPMENT BUSHINGS SFR-P Bushing for gas insulated switchgear UNMOUNTED 60 earth connection M4 60 60 30 83 M6 Dia. 91.5 Dia. 103.1 Dia. 4 equipment MOUNTED 97.5 Dia. 100 bail tab sealing O-ring gasket 6 fixing screws M6 equipment connection earth connection M4 In mm. 13

ACCESSORIES INTERFACE B Application For use with connectors and bushings with an interface B as described by CENELEC EN 50180 and 50181. Technical characteristics All these products, except the earthing plug, are tested for AC withstand and partial discharge prior to leaving the factory. Up to 24 kv 6/10 (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv DR Dead-end receptacle Fits over a bushing with a type B interface to provide 'deadend' facility. Is used with a BA restraint bail. Ordering instructions Order DR for 12 kv, KDR for 24 kv or MDR for 36 kv applications. Can be supplied with integral earth lead: add -/G. SOP Stand-off plug Is designed to support and 'dead-end' connectors with a type B interface when removed from equipment. Ordering instructions Order SOP for 12 kv, KSOP for 24 kv or MSOP for 36 kv applications. GP Earthing plug Is designed to support and earth connectors with a type B interface when removed from equipment. Ordering instructions Order GP for 12 kv, 24 or 36 kv applications. 04/2012 14

BIPA Basic insulating plug Acts as a tightening nut for the TE tee connector kit. The plug contains a voltage detection point. The conductive rubber protection cap is included. Ordering instructions Order BIPA for 12 kv, KBIPA for 24 kv or MBIPA for 36 kv applications. CP-SC Connecting plug For connecting a TE and one or more 430TB, TB or 440TB connectors, thus creating a multiple cable connection to equipment. Ordering instructions Order CP-SC for 12 kv, KCP-SC for 24 kv or MCP-SC for 36 kv applications. RTPA Reducing tap plug Provides a type A interface to a TE connector. A 'C' spanner, 600SW, is used to tighten the reducing tap plug on to its mating part. Ordering instructions Order RTPA for 12 kv or KRTPA for 24 kv applications. Order 600SW for the 'C' spanner. Kit MT Earthing kit for copper tape screened cables Contains a tinned copper braid (25 mm² - L=500 mm), a tinned copper wire for cleating and water sealing mastic. Ordering instructions Order Kit MT for 12 kv, 24 kv or 36 kv applications. 15

POSSIBLE ARRANGEMENTS INTERFACE B TE/G Single cable arrangement. Order TE/G for 12 kv, KTE/G for 24 kv or MTE/G for 36 kv applications. TE/G-P2 Dual cable arrangement. Order TE/G-P2 for 12 kv, KTE/G-P2 for 24 kv or MTE/G-P2 for 36 kv applications. 250 500 TCS clamping screw basic insulating plug connecting plug basic insulating plug 110 110 245 TE/G-P4 Single cable arrangement with tap-off. Order TE/G-P4 for 12 kv or KTE/G-P4 for 24 kv applications. 475 reducing tap plug type A separable connector 110 233 In mm. 04/2012 16

Connector on stand-off plug Order SOP for 12 kv, KSOP for 24 kv or MSOP for 36 kv applications. Connector on earthing plug Order GP for 12 kv, 24 kv and 36 kv applications. stand-off plug basic insulating plug basic insulating plug earthing plug Cable and equipment testing 600 TR test rod insulating shroud 110 In mm. 17

NOTES 04/2012 18

19

20

Additional catalogue information on power cable accessories is available by contacting us at the address below: Distributed by: a Nexans company Nexans Network Solutions N.V. - Div. Euromold Zuid III, Industrielaan 12, B-9320 Erembodegem Tel.: +32 (0)53 85 02 11 Fax: +32 (0)53 83 10 13 www.euromold.be sales.euromold@nexans.com 04/2012 Catalogue also available on CD-ROM