a Nexans company Catalogue 2009

Similar documents
a Nexans company Catalogue 2008

a Nexans company Catalogue 2015

INTERFACE A MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2012

a Nexans company Catalogue 2007

a Nexans company Catalogue 2006

Nexans Network Solutions Div. Euromold

Nexans Network Solutions Div. Euromold

THORNE & DERRICK UK TEL FAX TEL FAX

a Nexans company Catalogue 2009

a Nexans company Catalogue 2009

a Nexans company Catalogue 2007

THORNE & DERRICK UK TEL FAX TEL FAX

a Nexans company Catalogue 2011

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

a Nexans company Medium voltage symmetrical separable connectors - Interface C -

INTERFACE F MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

Nexans Network Solutions Div. Euromold

INTERFACE C MEDIUM VOLTAGE SYMMETRICAL SEPARABLE CONNECTORS CATALOGUE 2017

a Nexans company Catalogue 2015

Power cables accessories for use in potentially explosive atmospheres

a Nexans company Catalogue 2008

Nexans Network Solutions Div. Euromold

Shielded surge arresters

global leader in cables

High Voltage Accessories up to 72.5 kv

ACCESSORIES. Application For use with connectors and bushings with an interface C as described by CENELEC EN and

power cable accessories

(K),(M),(P)489TB/G Up to 42 kv

a Nexans company Catalogue 2012

(K),(M)430TB/G Up to 36 kv

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

Energy Division. PCA Single Column Polymeric Surge Arrester

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

Cold-shrinkable Silicone 12 kv - 24 kv - 36 kv

Medium Voltage. Joints & Terminations

Separable Connectors and Kits

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

Zinc-Oxide Surge Arrester TEXLIM Q-C

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

ELASTIMOLD UNDERGROUND CABLE ACCESSORIES

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

SEE PRODUCT GUIDE PG-PC-E FOR SURGE ARRESTER APPLICATIONS THREADED STUD 600 SERIES ELBOW THREADED STUD CONNECTING BUSHING EXTENDER COMPRESSION LUG

Zinc Oxide Surge Arrester EXLIM R

Power cable accessories catalogue


Bushings for High Voltage AC Applications

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

IEC Separable Connectors 17.5 kv/24 kv, 630A

Cellplux Plug-in Technology

CATALOG. Underground cable accessories

Completing the picture

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

Zinc Oxide Surge Arrester PEXLIM Q


1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Surge arresters Product overview

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

H e a t s h r i n k P r o d u c t G u i d e

Bushing Insulators according to DIN and UNEL Standards

Surge arrester POLIM-H..SD

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

BUSHINGS: GENERAL INFORMATION

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

Gas Insulated Switchgear

Item Code Description Unit Qty Total

INSTALLATION PRODUCTION TESTS

GROUP D. Switch & Protective device.

Nexans Switzerland. Global expert in cables and cabling system. Cossonay Production Plant

600 A 15 kv class T-OP II deadbreak connector

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

Transformer bushings, type GOH. Technical guide

DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5

MEDIUM VOLTAGE NETWORKS

3EP6 porcelain surge arrester

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

3 TM Cold Applied Barrier Boot System

Bowthorpe EMP LV/MV Outdoor Surge Arresters

3EK7 Medium Voltage Silicone Insulated Surge Arresters

Silicone Suspension/Tension Insulator 120kN. up to LIWV 450kV (BIL)

1500 kva Padmount Transformer delta Primary Voltage 208Y/120 Secondary Voltage

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

Surge arrester POLIM-C.. HD

Surge arrester POLIM-H.. ND

600 A 35 kv class BT-TAP deadbreak connector

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Transformer bushings, type GSA-OA Technical guide

(BUSINESS DAYS) 200A Separable Connectors

Transcription:

a Nexans company Catalogue 009

EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: pre-moulded EPDM or silicone rubber connectors, terminations and joints for cables and epoxy bushings for transformers and switchgear, as well as a large range of cold-shrinkable terminations and joints from to 4 kv. Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group. ISO 900 Certificate Since 99, Euromold s commitment to quality is demonstrated by its ISO 900 certification. International standards All our products meet the International standards like CENELEC HD 69., CENELEC EN 5080, IEC 6037, IEEE 386 & 404 or country specifications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are continuously performed in our test fields. Laboratory accreditation Since June 000, Euromold s independent ELAB laboratory obtained the BELTEST accreditation no.9-t-iso 705 conform with the European standards for laboratories ISO 705 for electrical testing of medium voltage cable accessories according to the International standards IEC 644 and HD 69. While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as standards and technology evolve. 09/009

SEPARABLE CONNECTORS AND BUSHINGS INTERFACE A Table of contents 58LR - elbow connector 5SR - straight connector 5SP - straight plug 56SA - surge arrester 80AR- /- /-3 and 80AR--G /-3-G - equipment bushings 50SFR-P - equipment bushing 80A-4P-O - in-air bushing PITO-E - plug-in termination Accessories Bail restraints Interface A Dimensions according to European CENELEC EN 5080 and 508 (in mm). 09/009 3

Connecting possibilities BUSHINGS / ACCESSORIES / CONNECTOR CONNECTION CONNECTORS / ACCESSORIES Equipment interface (K)80AR-(-G),- & -3(-G) Equipment bushing (K)50SFR-P Equipment bushing 80A-4P-O In-air bushing dead-ending of equipment two cables to equipment three cables to equipment one line to equipment one cable to equipment (K)50DR Dead-end receptacle (K)00T Tee connector (K)00X Cross connector (K)00T Tee connector in-line junction + tap-off PITO-E Plug-in termination (K)00X Cross connector in-line junction + tap-offs (K)50DP Dead-end plug (K)5SOP Stand-off plug 50GP Earthing plug (K)400RTPA Reducing tap plug (K)676RTPA Reducing tap plug cable insulation cable earthing tap-off 630/50 A tap-off 50/50 A disconnectable joint (K)5SR(/G) Straight connector (K)58LR(/G) Elbow connector (K)5SR(/G) Straight connector (K)5SP Straight plug in-line junction + tap-off (K)58LR(/G) Elbow connector (K)00T Tee connector in-line junction + tap-offs (K)00X Cross connector cable isolation (K)50DR Dead-end receptacle 4

58LR INTERFACE A ELBOW CONNECTOR Application Separable elbow connector designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors...). Also connects cable to cable, using the appropriate mating part. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory. Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design Separable connector comprising:. Conductive EPDM insert.. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type A - 50 A interface as described by CENELEC EN 5080 and 508. 5. Conductor connector. 6. Earthing lead (-/G version only). mm 4 5 3 60 mm Specifications and standards The separable connector 58LR meets the requirements of CENELEC HD 69.. 6 Separable connector type Voltage Um (kv) Current Ir (A) Conductor sizes (mm ) min max 09/009 58LR/G 58LR K58LR/G K58LR 4 4 50 50 50 50 6 70 6 5 70 95 5 95 5

Kit contents The complete (K)58LR or (K)58LR/G elbow connector kit comprises the following components: The kit also comprises lubricant, wipers, installation instructions and crimp chart. (K)58LR/G-W-X connector kit for Connector housing (K)58BLR/G-W Cable reducer CA smaller sizes Conductor contact 64LRC-X Pin contact + hex key 54LRF Bail restraint 50BA-B Connector housing (K)58BLR-W Cable adaptor TL (K)58LR-W-X+TL connector kit for larger sizes Select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type. Add a 'K' for use up to 4 kv. Example: The copper wire screened cable is 4 kv, 50 mm stranded aluminium with a diameter over core insulation of 0.4 mm. Order a K58LR-FG-50(K) M--+TL elbow connector kit. Table W Table X Conductor sizes (mm²) 6 5 35 50 70 95 Ordering part number 58LR/G--X 58LR/G-3-X 58LR-FB-X+TL 58LR-FG-X+TL 58LR-GA-X+TL 58LR-GAB-X+TL 58LR-GH-X+TL Aluminium Dia. over core insulation (mm) min.6 4.6 7.5 8.4 9.7.0 3. max 6. 8.7 0...5 3.8 6.4 Copper DIN hexagonal Deep indent DIN hexagonal - 5(K)M-- 35(K)M-- 50(K)M-- 70(K)M-- 95(K)M-- * - 5KM-- 35KM-- 50(K)M--* 70(K)M--* 95(K)M--* 6(K)M-- 5(K)M-- 35(K)M-- 50(K)M-- 70(K)M-- 95(K)M-- * The 58LR-FB is not compatible with these conductor contacts. For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-6 cables. Please contact our representative. For use with other cable types. Please contact our representative. For adapted bail restraints: see 'Bail restraints and typical applications'. For outdoor applications. Order: +MWS. Components can be ordered individually. 6

Application Separable straight connector designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors...). Also connects cable to cable, using the appropriate mating part. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory. 5SR INTERFACE A STRAIGHT CONNECTOR Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design Separable connector comprising:. Conductive EPDM insert.. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type A - 50 A interface as described by CENELEC EN 5080 and 508. 5. Conductor connector. 6. Earthing lead (-/G version only). 00 mm 6 55 mm Specifications and standards The separable connector 5SR meets the requirements of CENELEC HD 69.. 5 3 4 Separable connector type Voltage Um (kv) Current Ir (A) Conductor sizes (mm ) min max 09/009 5SR/G 5SR K5SR/G K5SR 4 4 50 50 50 50 6 70 6 5 70 95 5 95 7

Kit contents The complete (K)5SR or (K)5SR/G straight connector kit comprises the following components: The kit also comprises lubricant, wipers, installation instructions and crimp chart. (K)5SR/G-W-X connector kit for Connector housing (K)5SRH/G-W Cable reducer CA smaller sizes (K)5SR-W-X+TL connector kit for Conductor contact 5SRC-X Bail restraint 5BA Connector housing (K)5SRH-W Cable adaptor TL larger sizes Select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type. Add a 'K' for use up to 4 kv. Table W Ordering part number 5SR/G--X 5SR/G-3-X 5SR-FB-X+TL 5SR-FG-X+TL 5SR-GA-X+TL 5SR-GAB-X+TL 5SR-GH-X+TL Dia. over core insulation (mm) min max.6 6. 4.6 8.7 7.5 0. 8.4. 9.7.5.0 3.8 3. 6.4 Table X Example: The copper wire screened cable is 4 kv, 50 mm stranded aluminium with a diameter over core insulation of 0.4 mm. Order a K5SR-FG-50(K) M--+TL straight connector kit. Conductor sizes (mm²) 6 5 35 50 70 95 Aluminium Copper DIN hexagonal Deep indent DIN hexagonal - - 6(K)M-- 5(K)M-- 5KM-- 5(K)M-- 35(K)M-- 35KM-- 35(K)M-- 50(K)M-- 50(K)M--* 50(K)M-- 70(K)M-- 70(K)M--* 70(K)M-- 95(K)M-- * 95(K)M--* 95(K)M-- * The 5SR-FB is not compatible with these conductor contacts. For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-6 cables. Please contact our representative. For use with other cable types. Please contact our representative. For adapted bail restraints: see 'Bail restraints and typical applications'. For outdoor applications. Order: +MWS. Components can be ordered individually. 8

Application Separable straight plug designed to connect polymeric insulated cable to cable. Mates with the elbow, straight and branch joint connectors. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each straight plug is tested for AC withstand and partial discharge prior to leaving the factory. 5SP INTERFACE A STRAIGHT PLUG Up to 4 kv - 00 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design Separable connector comprising:. Conductive EPDM insert.. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type A interface as described by CENELEC EN 5080 and 508. 5. Conductor connector. 3 mm 5 3 4 Dia. 54 mm Separable plug type Voltage Um (kv) Current Ir (A) Conductor sizes (mm ) min max 09/009 5SP K5SP 4 00 00 6 6 95 95 9

Kit contents The complete (K)5SP straight plug kit comprises the following components: The kit also comprises lubricant, wipers, installation instructions and crimp chart. (K)5SP-W-X+TL straight plug kit Straight plug housing (K)5SPH-W Conductor contact 5SPC-X Cable adaptor TL Select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type. Add a 'K' for use up to 4 kv. Table W Ordering part number 5SP-A-X+TL-FA/FAB 5SP-B-X+TL-FB/FG 5SP-B-X+TL-GA/GAB 5SP-C-X+TL-GB/GH Dia. over core insulation (mm) min max 4.6 8.7 7.. 9.7 3.0. 6.4 Table X Example: The copper wire screened cable is kv, 50 mm stranded aluminium with a diameter over core insulation of 6.9 mm. Order a 5SP-A-50(K)M-- +TL-FA/FAB straight plug kit. Conductor sizes (mm²) 6 5 35 50 70 95 Aluminium Copper DIN hexagonal Deep indent DIN hexagonal - - 6(K)M-- 5(K)M-- 5KM-- 5(K)M-- 35(K)M-- 35KM-- 35(K)M-- 50(K)M-- 50(K)M-- 50(K)M-- 70(K)M-- 70(K)M-- 70(K)M-- 95(K)M-- 95(K)M-- 95(K)M-- For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-6 cables. Please contact our representative. For use with other cable types. Please contact our representative. For adapted bail restraints: see 'Bail restraints and typical applications'. For outdoor applications. Order: +MWS. Components can be ordered individually. 0

Application Surge arrester designed to protect and 4 kv class components, including transformers, equipment, cable and accessories from high voltage surges resulting from lightning or switching. Technical characteristics This surge arrester is a metal oxide varistor surge arrester in an elbow configuration. Each arrester is tested for AC withstand and partial discharge prior to leaving the factory. 56SA INTERFACE A SURGE ARRESTER Up to 4 kv 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design Surge arrester comprising:. Bail restraint.. Conductive EPDM insert. 3. Type A - 50 A interface as described by CENELEC EN 5080 and 508. 4. Pin contact. 5. Contact disc. 6. Copper shunt. 7. Metal oxide valve elements. 8. Aluminium spacer. 9. Steel cap. 0. Earth connection.. Insulating EPDM layer moulded between the insert and the jacket.. Conductive EPDM jacket. 5 3 4 5 6 7 8 6 9 0 Surge arrester type Nominal discharge current In (ka) Rated voltage Ur (kv) Max continuous operating voltage Uc (kv) Steep current residual voltage @ 5 ka [/0 µs] (kv) Lightning current residual voltage @ 5 ka [8/0 µs] (kv) High current impulse withstand (ka) 09/009 56SA- 56SA-5 56SA-8 56SA- 56SA-4 5 5 5 5 5 5 9 6 30.5 5.5 8.0.0 4.5 6.5 77.0 87.0 0.5 6.5 54.5 69.0 79.0 93.5 08.5 40 40 40 40 40

Typical application and dimensions In mm. To order the surge arrester, specify the surge arrester type, as described on previous page. Example: For a maximum continuous operating voltage (rms) of kv. Order a 56SA- surge arrester.

80AR- /80AR- /80AR-3 INTERFACE A EQUIPMENT BUSHINGS Application For use in equipment insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. Specifications and standards The plug-in type equipment bushings 80AR- meet the requirements of CENELEC EN 5080 and IEC 6037. Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design The equipment bushings are moulded epoxy insulated parts in accordance with CENELEC EN 5080. The 80AR- bushing has a length B outside this standard. The standard bushings, (K)80AR- /- /-3, are equipped with 6 tabs for the bail restraint. The (K)80AR--G and (K)80AR-3-G are equipped with 4 tabs and threaded inserts M6 (-G version). Type 80AR--G /-3-G Type 80AR- /- /-3 M6 8 8 A To order the equipment bushing, specify the type. The bushings are supplied with an earth jumper (/J) or an earth plate (/GS). This earth connection must be specified when ordering. E.g. K80AR-/J. Minimum oil level: - kv: 40 mm - 4 kv: 50 mm Dia. 6 Dia. 75 Dia. 0 M0 B 9 In mm. Equipment bushing type Voltage Ur (kv) Current Ir (A) A Dimensions (mm) B 09/009 80AR- K80AR- 80AR- K80AR- 80AR-3 K80AR-3 4 4 4 50 50 50 50 50 50 84 84 7 7 06 06 68 68 55 55 3

80AR-/GS 80AR--G/GS 80AR-/GS 80AR-3/GS and 80AR-3-G/GS Bushings FIXINGS FOR EQUIPMENT BUSHINGS 80AR-/J 80AR--G/J 80AR-/J 80AR-3/J and 80AR-3-G/J Bushings bushing interface fixing studs NF C 5-053 clamp E DIN 4 538 stud clamp equipment sealing gasket equipment connection tabs for bail restraint A DIN 4 538 fixing flange earth plate earth jumper Bushing clamping kit To order the bushing clamping kit, according to NFC 5-053 standards, simply specify KBCNF-00. Contents: - 3 x claw clamp NF - x sealing gasket. Fixing dimensions standards NF C 5-053 French standards. Bushing clamping kit To order the bushing clamping kit, according to DIN 4 538 standards, simply specify: KBCD-00. Contents: - x fixing flange A - 4 x stud clamp E - x sealing gasket. Fixing dimensions standards DIN 4 538 German standards. M8 or M0 M0 7 5 5 55 3 fixing studs Dia. 78 Dia. 6 4 fixing studs Dia. 78 Dia. 3 In mm. 4

Application For use in equipment insulated with SF 6 gas. Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 50SFR-P INTERFACE A EQUIPMENT BUSHING Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design The equipment bushing is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN 5080. The 50SFR-P bushing has a shank outside this standard, adapted to use in SF 6 gas. Dia. 70 Dia. 48.5 3 Specifications and standards The plug-in type equipment bushings 50SFR-P meet the requirements of CENELEC EN 5080 and IEC 6037. 95 74 To order the equipment bushing, simply specify the type. Dia. 70 Dia. 09 M0 Dia. 0 In mm. Equipment bushing type Voltage Ur (kv) Current Ir (A) 09/009 50SFR-P K50SFR-P 4 50 50 5

FIXINGS FOR EQUIPMENT BUSHINGS 50SFR-P Bushing for gas insulated switchgear UNMOUNTED 60 60 60 M4 83 M6 Dia. 9.5 Dia. 03. equipment MOUNTED bushing interface 6 fixing screws M6 sealing O-ring gasket earth connection M4 equipment connection In mm. 6

Application For use in equipment insulated with air, typically for dry type transformers, motors, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 80A-4P-O INTERFACE A IN-AIR BUSHING Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Specifications and standards The plug-in type equipment bushings 80A-4P-O are moulded epoxy insulated parts and meet the requirements of CENELEC EN 508, IEC 6007 and IEC 6037. To order the equipment bushing, specify the type. The bushings are supplied with an earth jumper. To include the ring clamp, add: /B, if per British standards /D, if per German standards /F, if per French standards. E.g. 80A-4P-O/F. In mm. Equipment bushing type Voltage Ur (kv) Current Ir (A) Creepage distance A-B (mm) 09/009 80A-4P-O 80A-4P-O 4 50 50 630 630 7

80A-4P-O In-air bushing bushing interface fixing studs and nuts M0 earth jumper FIXINGS FOR EQUIPMENT BUSHINGS equipment gasket equipment connection fixing flange BCA-B or BCA-D fixing flange BCA-F F tabs for bail restraint Dia. 94.5 Dia. 4 Dia. 0 Dia. 0 4 Dia. 94.5 Dia. 0 F 6 BS 56 stand.: 0 DIN 4 538 stand.: 3 Dia. 50 Type BCA-B : BS 56 British standards Type BCA-D : DIN 4 538 German standards Fixing dimensions standards DIN 4 538 German standards. M0 5 55 0 Dia. 50 Type BCA-F : NFC 5-053 French standards M8 or M0 7 5 Fixing dimensions standards NF C 5-053 French standards. 4 fixing studs 3 fixing studs Dia. 8 Dia. 3 Dia. 8 Dia. 6 In mm. 8

Application Separable termination designed to connect overhead lines or bus bars to equipment. Is suitable for indoor and outdoor use for medium polluted atmosphere. Technical characteristics Each plug-in termination is tested for AC withstand prior to leaving the factory. PITO-E PLUG-IN TERMINATION Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design The plug-in termination is a moulded epoxy insulated part. It meets the type A - 50 A interface as described in CENELEC EN 5080 and 508. Specifications and standards The separable termination PITO-E meets the requirements of IEC 6037. To order the plug-in termination for or 4 kv, specify PITO-E. The kit includes the bail restraint and brass nuts. In mm. Plug-in termination type Voltage Ur (kv) Current Ir (A) Creepage distance A-B (mm) 09/009 PITO-E PITO-E 4 50 50 50 50 9

ACCESSORIES INTERFACE A Application For use with connectors and bushings with an interface A as described by CENELEC EN 5080 and 508. Technical characteristics All these products, except the earthing plug, are tested for AC withstand and partial discharge prior to leaving the factory. Up to 4 kv 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv 50DR Dead-end receptacle Fits over a bushing with a type A interface to provide 'deadend' facility. Renders the assembly watertight. Order 50DR for kv or K50DR for 4 kv applications. The dead-end receptacle can be supplied with an earth lead. Order: -/G. E.g. K50DR/G. 50DP Dead-end plug Plugs into connectors or receptacles to provide 'deadend' facility. Renders the assembly watertight Order 50DP for kv or K50DP for 4 kv applications. 5SOP Stand-off plug Is designed to support and 'dead-end' connectors with a type A interface when removed from equipment. Order 5SOP for kv or K5SOP for 4 kv applications. 50GP Earthing plug Is designed to support and earth connectors with a type A interface when removed from equipment. Order 50GP for kv or 4 kv applications. 09/009 0

00T Separable tee connector Is designed to connect three cables of the same or varying sizes or two cables to equipment. For an adapted bail, please refer to the catalogue or contact our representative. Order 00T for kv or K00T for 4 kv applications. 00X Separable cross connector Is designed to connect four cables of the same or varying sizes or three cables to equipment. For an adapted bail, please refer to the catalogue or contact our representative. Order 00X for kv or K00X for 4 kv applications. 50J3-U-8 Three-way junction Provides a flexible means of connecting two or three cables of the same or varying sizes. For an adapted bail, please refer to the catalogue or contact our representative. Order 50J3-U-8 for kv or K50J3-U-8 for 4 kv applications. Kit MT Earthing kit for copper tape screened cables Contains a tinned copper braid (5 mm² - L=500 mm), a tinned copper wire for cleating and water sealing mastic. Order Kit MT for kv or 4 kv applications.

BAIL RESTRAINTS INTERFACE A Application For use with connectors, receptacles and bushings with an interface A as described by CENELEC EN 5080 and 508. The type of bail restraint is defined by its intended use with different types of connector, receptacle and/or bushing. To order the bail restraint, specify the type needed. 47BA. (K)5SR straight connector,. (K)00T tee connector and 3. (K)50DR dead-end receptacle. 49BA. (K)58LR elbow connector,. (K)00T tee connector and 3. (K)50DR dead-end receptacle. 3 3 48BA. (K)58LR elbow connector and. (K)50DP dead-end plug. 50BA-B. (K)58LR elbow connector and. an interface A equipment bushing (shown), 50GP earthing plug, (K)5SOP stand-off plug (shown) or (K)50J3-U-8 three-way junction. 09/009

50TB-. (K)00T tee connector and. an interface A equipment bushing (shown), 50GP earthing plug, (K)5SOP stand-off plug (shown) or (K)50J3-U-8 three way junction. 53BA. (K)5SR straight connector and. (K)50DP dead-end plug. 5BA. (K)5SR straight connector and. an interface A equipment bushing (shown), 50GP earthing plug, (K)5SOP stand-off plug (shown) or (K)50J3-U-8 three-way junction. 54BA-CS80. (K)5SP straight plug and. (K)50DR dead-end receptacle. 55BA-. x (K)5SR straight connector and. (K)00T tee connector. 5BA. (K)50DR dead-end receptacle and. an interface A equipment bushing (shown) or (K)50J3-U-8 three-way junction. 55BA- - CS80. (K)5SP straight plug and. (K)58LR elbow connector or 3. (K)00T tee connector. 3 3

56BA-. (K)00T tee connector and. (K)50DP dead-end plug. 59BA. x (K)58LR elbow connector and. (K)00T tee connector 57BA - CS8. (K)5SR straight connector and. (K)5SP straight plug. 00BA. (K)5SR straight connector and. (K)00X cross connector. 58BA. (K)5SR straight connector,. (K)00T tee connector and 3. (K)58LR elbow connector. 3 0BA. (K)58LR elbow connector and. (K)00X cross connector. 4

0BA. (K)5SR straight connector,. (K)00X cross connector and 3. (K)50DR dead-end receptacle. 3 06BA. (K)5SR straight connector,. (K)00X cross connector and 3. (K)58LR elbow connector. 3 03BA. (K)58LR elbow connector,. (K)00X cross connector and 3. (K)50DR dead-end receptacle. 3 07BA. x (K)58LR elbow connector and. (K)00X cross connector. 04BA. (K)00X cross connector and. (K)5SP straight plug. 08BA. (K)00X cross connector and. (K)50DR dead-end receptacle. 05BA. (K)00X cross connector and. x (K)5SR straight connector. 5

Additional catalogue information on power cable accessories is available by contacting us at the address below: Distributed by: Nexans Network Solutions N.V. - Div. Euromold Zuid III, Industrielaan, B-930 Erembodegem Tel.: +3 (0)53 85 0 Fax: +3 (0)53 83 0 3 www.nexans.com info.euromold@nexans.com 09/009 Catalogue also available on CD-ROM