Nexans Network Solutions Div. Euromold

Similar documents
a Nexans company Catalogue 2015

a Nexans company Catalogue 2009

INTERFACE A MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

a Nexans company Catalogue 2008

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2012

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2006

a Nexans company Catalogue 2007

THORNE & DERRICK UK TEL FAX TEL FAX

a Nexans company Catalogue 2009

THORNE & DERRICK UK TEL FAX TEL FAX

a Nexans company Catalogue 2009

a Nexans company Catalogue 2011

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

a Nexans company Medium voltage symmetrical separable connectors - Interface C -

a Nexans company Catalogue 2007

INTERFACE F MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

INTERFACE C MEDIUM VOLTAGE SYMMETRICAL SEPARABLE CONNECTORS CATALOGUE 2017

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2015

Power cables accessories for use in potentially explosive atmospheres

Shielded surge arresters

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2008

global leader in cables

High Voltage Accessories up to 72.5 kv

ACCESSORIES. Application For use with connectors and bushings with an interface C as described by CENELEC EN and

power cable accessories

a Nexans company Catalogue 2012

Nexans WINDLINK connection system. Nexans Power Accessories Germany GmbH

(K),(M),(P)489TB/G Up to 42 kv

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

Energy Division. PCA Single Column Polymeric Surge Arrester

(K),(M)430TB/G Up to 36 kv

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Completing the picture

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

Separable Connectors and Kits

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Medium Voltage. Joints & Terminations

ELASTIMOLD UNDERGROUND CABLE ACCESSORIES

Zinc-Oxide Surge Arrester TEXLIM Q-C

Cellplux Plug-in Technology

IEC Separable Connectors 17.5 kv/24 kv, 630A


Zinc Oxide Surge Arrester EXLIM R

Bushings for High Voltage AC Applications

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Cold-shrinkable Silicone 12 kv - 24 kv - 36 kv

CATALOG. Underground cable accessories

Bushing Insulators according to DIN and UNEL Standards

Surge arrester POLIM-H..SD

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

SEE PRODUCT GUIDE PG-PC-E FOR SURGE ARRESTER APPLICATIONS THREADED STUD 600 SERIES ELBOW THREADED STUD CONNECTING BUSHING EXTENDER COMPRESSION LUG

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

Surge arresters Product overview

IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

Zinc Oxide Surge Arrester PEXLIM Q

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Nexans Switzerland. Global expert in cables and cabling system. Cossonay Production Plant

Gas Insulated Switchgear

H e a t s h r i n k P r o d u c t G u i d e

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

Transformer bushings, type GOH. Technical guide

3EP6 porcelain surge arrester

Power cable accessories catalogue

(BUSINESS DAYS) 200A Separable Connectors

BUSHINGS: GENERAL INFORMATION

GROUP D. Switch & Protective device.

3EK7 Medium Voltage Silicone Insulated Surge Arresters

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC


Silicone Suspension/Tension Insulator 120kN. up to LIWV 450kV (BIL)

Surge arrester POLIM-C.. HD

Surge arrester POLIM-H.. ND

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3

DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

MEDIUM VOLTAGE NETWORKS

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

KEVA 24 Cxx(c) Indoor voltage sensors for NEXANS Instructions for installation, use and maintenance

Bowthorpe EMP LV/MV Outdoor Surge Arresters

Item Code Description Unit Qty Total

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

TE S RAYCHEM RSTI-CC-58 SCREENED, SEPARABLE COUPLING SYSTEM

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Transformer bushings, type GOA 250. Installation and maintenance guide

Contents. The RM6 range

Transcription:

Catalogue 0

Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: premoulded EPDM rubber connectors for cables and epoxy bushings for transformers and switchgear, as well as a large range of coldshrinkable terminations and joints from to 4 kv. Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group. ISO 900 Certificate Since 99, Euromold s commitment to quality is demonstrated by its ISO 900 certification. International standards All our products meet the International standards like CENELEC HD 69., CENELEC EN 5080, IEC 6037, IEC 6050-4 or country specifications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are continuously performed in our test fields. Laboratory accreditation Since June 000, Euromold s independent ELAB laboratory obtained the BELAC accreditation no.44-test conform with the European standards for laboratories ISO 705 for electrical testing of low and medium voltage cable accessories according to the international standards HD 63 and HD 69. While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as standards and technology evolve.

SEPARABLE CONNECTORS AND BUSHINGS INTERFACE A Table of contents 58LR - elbow connector 5SR - straight connector 5SP - straight plug 56SA - surge arrester 80AR- /- /-3 and 80AR--G /-3-G - equipment bushings 50SFR-P - equipment bushing 80A-4P-O - in-air bushing PITO-E - plug-in termination Accessories Bail restraints Interface A Dimensions according to European CENELEC EN 5080 and 508 (in mm). Dia. 3.5 ±0. Dia. 3 +0. - 0.3 Dia. for pin 7.9 +0.0-0.05 48 0-0. 9 min Dia. 48.5 ±0. -03-03

Connecting possibilities BUSHINGS / ACCESSORIES / CONNECTOR CONNECTION CONNECTORS / ACCESSORIES Equipment interface (K)80AR-(-G),- & -3(-G) Equipment bushing (K)50SFR-P Equipment bushing 80A-4P-O In-air bushing dead-ending of equipment two cables to equipment three cables to equipment one line to equipment one cable to equipment (K)50DR Dead-end receptacle (K)00T Tee connector (K)00X Cross connector (K)00T Tee connector in-line junction + tap-off PITO-E Plug-in termination (K)00X Cross connector in-line junction + tap-offs (K)50DP Dead-end plug (K)5SOP Stand-off plug 50GP Earthing plug (K)400RTPA Reducing tap plug (K)676RTPA Reducing tap plug cable insulation cable earthing tap-off 630/50 A tap-off 50/50 A disconnectable joint (K)5SR(/G) Straight connector (K)58LR(/G) Elbow connector (K)5SR(/G) Straight connector (K)5SP Straight plug in-line junction + tap-off (K)58LR(/G) Elbow connector (K)00T Tee connector in-line junction + tap-offs (K)00X Cross connector cable isolation (K)50DR Dead-end receptacle 0/0 Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com 3

Application Separable elbow connector designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors...). Also connects cable to cable, using the appropriate mating part. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory. 58LR INTERFACE A ELBOW CONNECTOR Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design Separable connector comprising:. Conductive EPDM insert.. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type A - 50 A interface as described by CENELEC EN 5080 and 508. 5. Conductor connector. 6. Voltage test point. 7. Earthing lead (-/G version only). mm 4 5 3 60 mm 6 7 Specifications and standards The separable connector 58LR meets the requirements of CENELEC HD 69.. Separable connector type Voltage Um (kv) Current Ir (A) Conductor sizes (mm ) min max 58LR/G 58LR K58LR/G K58LR 4 4 50 50 50 50 6 70 6 5 95 95 70 95-03-03 4

Kit contents The complete (K)58LR or (K)58LR/G elbow connector kit comprises the following components: Connector housing (K)58BLR/G-W The kit also comprises lubricant, wipers, installation instructions and crimp chart. Cable reducer CA (K)58LR/G-W-X connector kit for smaller sizes Conductor contact 64LRC-X or 64LRMC-X Pin contact + hex key 54LRF Bail restraint 50BA-B Connector housing (K)58BLR-W Cable adaptor TL (K)58LR-W-X+TL connector kit for larger sizes Select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type. Add a 'K' for use up to 4 kv. Example: The copper wire screened cable is 4 kv, 50 mm stranded aluminium with a diameter over core insulation of 0.4 mm. Order a K58LR-FG-50(K)M- -+TL elbow connector kit. For an option with a bolted conductor contact, specify the ordering part number below. Table W Table X Conductor sizes (mm²) 6 5 35 50 70 95 Ordering part number 58LR/G--X 58LR/G-3-X 58LR-FB-X+TL 58LR-FG-X+TL 58LR-GA-X+TL 58LR-GAB-X+TL 58LR-GH-X+TL Aluminium Copper DIN hexagonal Deep indent DIN hexagonal - 5(K)M-- 35(K)M-- 50(K)M-- 70(K)M-- 95(K)M-- * - 5KM-- 35KM-- 50(K)M--* 70(K)M--* 95(K)M--* * The 58LR-FB is not compatible with these conductor contacts. Dia. over core insulation (mm) min max.6 4.6 7.5 8.4 9.7.0 3.6 6. 8.7 0...5 3.8 6.4 6(K)M-- 5(K)M-- 35(K)M-- 50(K)M-- 70(K)M-- 95(K)M-- Ordering part number Dia. over core insulation (mm) Conductor sizes (mm²) 58LR/G-3-5.95-4-5 58LR-GAS-50.95-4-5+TL 4.6 -.7 9.7-5.4 35-70 5-95 For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-6 cables. Please contact our representative. For use with other cable types. Please contact our representative. For adapted bail restraints: see 'Bail restraints and typical applications'. For outdoor applications. Order: +MWS. Components can be ordered individually. Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com 5

Application Separable straight connector designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors...). Also connects cable to cable, using the appropriate mating part. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory. 5SR INTERFACE A STRAIGHT CONNECTOR Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design Separable connector comprising:. Conductive EPDM insert.. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type A - 50 A interface as described by CENELEC EN 5080 and 508. 5. Conductor connector. 6. Voltage test point. 7. Earthing lead (-/G version only). 00 mm 7 Specifications and standards The separable connector 5SR meets the requirements of CENELEC HD 69.. 55 mm 5 3 6 4 Separable connector type Voltage Um (kv) Current Ir (A) Conductor sizes (mm ) min max 5SR/G 5SR K5SR/G K5SR 4 4 50 50 50 50 6 70 6 5 70 95 5 95-03-03 6

Kit contents The complete (K)5SR or (K)5SR/G straight connector kit comprises the following components: Connector housing (K)5SRH/G-W The kit also comprises lubricant, wipers, installation instructions and crimp chart. Cable reducer CA (K)5SR/G-W-X connector kit for smaller sizes Conductor contact 5SRC-X or 5SRMC-X Bail restraint 5BA Connector housing (K)5SRH-W Cable adaptor TL (K)5SR-W-X+TL connector kit for larger sizes Select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type. Add a 'K' for use up to 4 kv. Example: The copper wire screened cable is 4 kv, 50 mm stranded aluminium with a diameter over core insulation of 0.4 mm. Order a K5SR-FG-50(K)M- -+TL straight connector kit. For an option with a bolted conductor contact, specify the ordering part number below. Table W Table X Conductor sizes (mm²) 6 5 35 50 70 95 Ordering part number 5SR/G--X 5SR/G-3-X 5SR-FB-X+TL 5SR-FG-X+TL 5SR-GA-X+TL 5SR-GAB-X+TL 5SR-GH-X+TL Aluminium Copper DIN hexagonal Deep indent DIN hexagonal - 5(K)M-- 35(K)M-- 50(K)M-- 70(K)M-- 95(K)M-- * - 5KM-- 35KM-- 50(K)M--* 70(K)M--* 95(K)M--* * The 5SR-FB is not compatible with these conductor contacts. Dia. over core insulation (mm) min max.6 4.6 7.5 8.4 9.7.0 3.6 6. 8.7 0...5 3.8 6.4 6(K)M-- 5(K)M-- 35(K)M-- 50(K)M-- 70(K)M-- 95(K)M-- Ordering part number Dia. over core insulation (mm) Conductor sizes (mm²) 5SR/G-3-5.95-4-5 5SR-GAS-50.95-4-5+TL 4.6 -.7 9.7-5.4 35-70 5-95 For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-6 cables. Please contact our representative. For use with other cable types. Please contact our representative. For adapted bail restraints: see 'Bail restraints and typical applications'. For outdoor applications. Order: +MWS. Components can be ordered individually. Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com 7

Application Separable straight plug designed to connect polymeric insulated cable to cable. Mates with the elbow, straight and branch joint connectors. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each straight plug is tested for AC withstand and partial discharge prior to leaving the factory. 5SP INTERFACE A STRAIGHT PLUG Up to 4 kv - 00 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design Separable connector comprising:. Conductive EPDM insert.. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type A interface as described by CENELEC EN 5080 and 508. 5. Conductor connector. 3 mm 5 3 4 Dia. 54 mm Separable plug type 5SP K5SP Voltage Um (kv) 4 Current Ir (A) 00 00 Conductor sizes (mm ) min max 6 95 6 95-03-03 8

Kit contents The complete (K)5SP straight plug kit comprises the following components: The kit also comprises lubricant, wipers, installation instructions and crimp chart. (K)5SP-W-X+TL straight plug kit Straight plug housing (K)5SPH-W Conductor contact 5SPC-X Cable adaptor TL Select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to the conductor size and type. Add a 'K' for use up to 4 kv. Table W Ordering part number 5SP-A-X+TL-FA/FAB 5SP-B-X+TL-FB/FG 5SP-B-X+TL-GA/GAB 5SP-C-X+TL-GB/GH Dia. over core insulation (mm) min max 4.6 8.7 7.. 9.7 3.0. 6.4 Table X Example: The copper wire screened cable is kv, 50 mm stranded aluminium with a diameter over core insulation of 6.9 mm. Order a 5SP-A-50(K)M-- +TL-FA/FAB straight plug kit. Conductor sizes (mm²) 6 5 35 50 70 95 Aluminium Copper DIN hexagonal Deep indent DIN hexagonal - - 6(K)M-- 5(K)M-- 5KM-- 5(K)M-- 35(K)M-- 35KM-- 35(K)M-- 50(K)M-- 50(K)M-- 50(K)M-- 70(K)M-- 70(K)M-- 70(K)M-- 95(K)M-- 95(K)M-- 95(K)M-- For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-6 cables. Please contact our representative. For use with other cable types. Please contact our representative. For adapted bail restraints: see 'Bail restraints and typical applications'. For outdoor applications. Order: +MWS. Components can be ordered individually. Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com 9

Application Surge arrester designed to protect and 4 kv class components, including transformers, equipment, cable and accessories from high voltage surges resulting from lightning or switching. Technical characteristics This surge arrester is a metal oxide varistor surge arrester in an elbow configuration. Each arrester is tested for AC withstand and partial discharge prior to leaving the factory. 56SA INTERFACE A SURGE ARRESTER Up to 4 kv 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design Surge arrester comprising:. Bail restraint.. Conductive EPDM insert. 3. Type A - 50 A interface as described by CENELEC EN 5080 and 508. 4. Pin contact. 5. Contact disc. 6. Copper shunt. 7. Metal oxide valve elements. 8. Aluminium spacer. 9. Steel cap. 0. Earth connection.. Insulating EPDM layer moulded between the insert and the jacket.. Conductive EPDM jacket. 5 3 4 5 6 7 6 8 9 0 Surge arrester type Nominal discharge current In (ka) Rated voltage Ur (kv) Max continuous operating voltage Uc (kv) Steep current residual voltage @ 5 ka [/0 μs] (kv) Lightning current residual voltage @ 5 ka [8/0 μs] (kv) High current impulse withstand (ka) 56SA- 56SA-5 56SA-8 56SA- 56SA-4 5 5 5 5 5 5 9 6 30.5 5.5 8.0.0 4.5 6.5 77.0 87.0 0.5 6.5 54.5 69.0 79.0 93.5 08.5 40 40 40 40 40-03-03 0

Typical application and dimensions 45 0 95 56 3 K400RTPA reducing tap plug K400TE/G, K400TB/G or K440TB/G connector Surge arrester 56SA-4 330 Note: the surge arrester body needs to be positioned vertically after installation. In mm. To order the surge arrester, specify the surge arrester type, as described on previous page. Example: For a maximum continuous operating voltage (r.m.s.) of kv. Order a 56SA- surge arrester. Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com

80AR- /80AR- /80AR-3 INTERFACE A EQUIPMENT BUSHINGS Application For use in equipment insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. Specifications and standards The plug-in type equipment bushings 80AR- meet the requirements of CENELEC EN 5080 and IEC 6037. Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design The equipment bushings are moulded epoxy insulated parts in accordance with CENELEC EN 5080. The 80AR- bushing has a length B outside this standard. The standard bushings, (K)80AR- /- /-3, are equipped with 6 tabs for the bail restraint. The (K)80AR--G and (K)80AR-3-G are equipped with 4 tabs and threaded inserts M6 (-G version). Type 80AR--G /-3-G Type 80AR- /- /-3 M6 8 8 A B To order the equipment bushing, specify the type. The bushings are supplied with an earth jumper (/J) or an earth plate (/GS). This earth connection must be specified when ordering. E.g. K80AR-/J. Minimum oil level: - kv: 40 mm - 4 kv: 50 mm Dia. 6 Dia. 75 Dia. 0 M0 9 In mm. Equipment bushing type Voltage Ur (kv) Current Ir (A) A Dimensions (mm) B 80AR- K80AR- 80AR- K80AR- 80AR-3 K80AR-3 4 4 4 50 50 50 50 50 50 84 84 7 7 06 06 68 68 55 55-03-03

80AR-/GS 80AR--G/GS 80AR-/GS 80AR-3/GS and 80AR-3-G/GS Bushings FIXINGS FOR EQUIPMENT BUSHINGS 80AR-/J 80AR--G/J 80AR-/J 80AR-3/J and 80AR-3-G/J Bushings bushing interface fixing studs NF C 5-053 clamp E DIN 4 538 stud clamp equipment sealing gasket equipment connection tabs for bail restraint A DIN 4 538 fixing flange earth plate earth jumper Bushing clamping kit To order the bushing clamping kit, according to NFC 5-053 standards, simply specify KBCNF-00. Contents: - 3 x claw clamp NF - x sealing gasket. Fixing dimensions standards NF C 5-053 French standards. Bushing clamping kit To order the bushing clamping kit, according to DIN 4 538 standards, simply specify: KBCD-00. Contents: - x fixing flange A - 4 x stud clamp E - x sealing gasket. Fixing dimensions standards DIN 4 538 German standards. M8 or M0 M0 5 30 55 30 3 fixing studs Dia. 78 Dia. 6 4 fixing studs Dia. 78 Dia. 3 In mm. Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com 3

Application For use in equipment insulated with SF 6 gas. Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 50SFR-P INTERFACE A EQUIPMENT BUSHING Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design The equipment bushing is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN 5080. The 50SFR-P bushing has a shank outside this standard, adapted to use in SF 6 gas. Dia. 70 Dia. 48.5 3 Specifications and standards The plug-in type equipment bushings 50SFR-P meet the requirements of CENELEC EN 5080 and IEC 6037. 95 74 To order the equipment bushing, simply specify the type. Dia. 70 Dia. 09 M0 Dia. 0 In mm. Equipment bushing type 50SFR-P K50SFR-P Voltage Ur (kv) 4 Current Ir (A) 50 50-03-03 4

FIXINGS FOR EQUIPMENT BUSHINGS 50SFR-P Bushing for gas insulated switchgear UNMOUNTED 60 earth connection M4 60 60 30 83 M6 Dia. 9.5 Dia. 03. Dia. 4 equipment MOUNTED 53.5 88.5 bail tab sealing O-ring gasket 6 fixing screws M6 equipment connection earth connection M4 In mm. Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com 5

80A-4P-O INTERFACE A IN-AIR BUSHING Application For use in equipment insulated with air, typically for dry type transformers, motors, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Specifications and standards The plug-in type equipment bushings 80A-4P-O are moulded epoxy insulated parts and meet the requirements of CENELEC EN 508, IEC 6007 and IEC 6037. A Dia. 70 Dia. 0 59 0 To order the equipment bushing, specify the type. The bushings are supplied with an earth jumper. To include the ring clamp, add: /B, if per British standards /D, if per German standards /F, if per French standards. E.g. 80A-4P-O/F. 50 35 Dia. 6 0 B Dia. 80 M0 In mm. Equipment bushing type 80A-4P-O 80A-4P-O Voltage Ur (kv) 4 Current Ir (A) 50 50 Creepage distance A-B (mm) 630 630-03-03 6

80A-4P-O In-air bushing bushing interface fixing studs and nuts M0 earth jumper FIXINGS FOR EQUIPMENT BUSHINGS equipment gasket equipment connection fixing flange BCA-B or BCA-D fixing flange BCA-F tabs for bail restraint Dia. 94.5 4 Dia. 0 Dia. 0 Dia. 94.5 4 Dia. Dia. 0 F 6 BS 56 stand.: 0 DIN 4 538 stand.: 3 Dia. 50 Type BCA-B : BS 56 British standards Type BCA-D : DIN 4 538 German standards Fixing dimensions standards DIN 4 538 German standards. 0 Dia. 50 Type BCA-F : NFC 5-053 French standards Fixing dimensions standards NF C 5-053 French standards. M0 M0 55 0 5 0 4 fixing studs 3 fixing studs Dia. 8 Dia. 3 Dia. 8 Dia. 6 Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com In mm. 7

Application Separable termination designed to connect overhead lines or bus bars to equipment. Is suitable for indoor and outdoor use for medium polluted atmosphere. Technical characteristics Each plug-in termination is tested for AC withstand prior to leaving the factory. PITO-E PLUG-IN TERMINATION Up to 4 kv - 50 A 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv Design The plug-in termination is a moulded epoxy insulated part. It meets the type A - 50 A interface as described in CENELEC EN 5080 and 508. Specifications and standards The separable termination PITO-E meets the requirements of IEC 6037. To order the plug-in termination for or 4 kv, specify PITO-E. The kit includes the bail restraint and brass nuts. In mm. Plug-in termination type PITO-E PITO-E Voltage Ur (kv) 4 Current Ir (A) 50 50 Creepage distance A-B (mm) 50 50-03-03 8

ACCESSORIES INTERFACE A Application For use with connectors and bushings with an interface A as described by CENELEC EN 5080 and 508. Technical characteristics All these products, except the earthing plug, are tested for AC withstand and partial discharge prior to leaving the factory. Up to 4 kv 6/0 () kv 6.35/ () kv 8.7/5 (7.5) kv /0 (4) kv.7/ (4) kv 50DR Dead-end receptacle Fits over a bushing with a type A interface to provide 'deadend' facility. Renders the assembly watertight. Order 50DR for kv or K50DR for 4 kv applications. The dead-end receptacle can be supplied with an earth lead. Order: -/G. E.g. K50DR/G. 50DP Dead-end plug Plugs into connectors or receptacles to provide 'deadend' facility. Renders the assembly watertight. Order 50DP for kv or K50DP for 4 kv applications. 5SOP Stand-off plug Is designed to support and 'dead-end' connectors with a type A interface when removed from equipment. Order 5SOP for kv or K5SOP for 4 kv applications. 0/0 50GP Earthing plug Is designed to support and earth connectors with a type A interface when removed from equipment. Order 50GP for kv or 4 kv applications. 9

00T Separable tee connector Is designed to connect three cables of the same or varying sizes or two cables to equipment. For an adapted bail, please refer to the catalogue or contact our representative. Order 00T for kv or K00T for 4 kv applications. 00X Separable cross connector Is designed to connect four cables of the same or varying sizes or three cables to equipment. For an adapted bail, please refer to the catalogue or contact our representative. Order 00X for kv or K00X for 4 kv applications. 50J3-U-8 Three-way junction Provides a flexible means of connecting two or three cables of the same or varying sizes. For an adapted bail, please refer to the catalogue or contact our representative. Order 50J3-U-8 for kv or K50J3-U-8 for 4 kv applications. Kit MT Earthing kit for copper tape screened cables Contains a tinned copper braid (5 mm² - L=500 mm), a tinned copper wire for cleating and water sealing mastic. Order Kit MT for kv or 4 kv applications. 0/0 0 Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com

BAIL RESTRAINTS INTERFACE A Application For use with connectors, receptacles and bushings with an interface A as described by CENELEC EN 5080 and 508. The type of bail restraint is defined by its intended use with different types of connector, receptacle and/or bushing. To order the bail restraint, specify the type needed. 47BA. (K)5SR straight connector,. (K)00T tee connector and 3. (K)50DR dead-end receptacle. 49BA. (K)58LR elbow connector,. (K)00T tee connector and 3. (K)50DR dead-end receptacle. 3 3 48BA. (K)58LR elbow connector and. (K)50DP dead-end plug. 50BA-B. (K)58LR elbow connector and. an interface A equipment bushing (shown), 50GP earthing plug, (K)5SOP stand-off plug (shown) or (K)50J3-U-8 three-way junction. 0/0

50TB-. (K)00T tee connector and. an interface A equipment bushing (shown), 50GP earthing plug, (K)5SOP stand-off plug (shown) or (K)50J3-U-8 three way junction. 53BA. (K)5SR straight connector and. (K)50DP dead-end plug. 5BA. (K)5SR straight connector and. an interface A equipment bushing (shown), 50GP earthing plug, (K)5SOP stand-off plug (shown) or (K)50J3-U-8 three-way junction. 54BA-CS80. (K)5SP straight plug and. (K)50DR dead-end receptacle. 55BA-. x (K)5SR straight connector and. (K)00T tee connector. 5BA. (K)50DR dead-end receptacle and. an interface A equipment bushing (shown) or (K)50J3-U-8 three-way junction. 55BA- - CS80. (K)5SP straight plug and. (K)58LR elbow connector or 3. (K)00T tee connector. 3 0/0 Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com

56BA-. (K)00T tee connector and. (K)50DP dead-end plug. 59BA. x (K)58LR elbow connector and. (K)00T tee connector. 57BA - CS8. (K)5SR straight connector and. (K)5SP straight plug. 00BA. (K)5SR straight connector and. (K)00X cross connector. 58BA. (K)5SR straight connector,. (K)00T tee connector and 3. (K)58LR elbow connector. 3 0BA. (K)58LR elbow connector and. (K)00X cross connector. 0/0 Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com 3

0BA. (K)5SR straight connector,. (K)00X cross connector and 3. (K)50DR dead-end receptacle. 3 06BA. (K)5SR straight connector,. (K)00X cross connector and 3. (K)58LR elbow connector. 3 03BA. (K)58LR elbow connector,. (K)00X cross connector and 3. (K)50DR dead-end receptacle. 3 07BA. x (K)58LR elbow connector and. (K)00X cross connector. 04BA. (K)00X cross connector and. (K)5SP straight plug. 08BA. (K)00X cross connector and. (K)50DR dead-end receptacle. 05BA. (K)00X cross connector and. x (K)5SR straight connector. 0/0 4 Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com

Additional catalogue information on power cable accessories is available by contacting us at the address below: Distributed by: Nexans Power Accessories Germany GmbH Ferdinand-Porsche-Str. 9508 Hof/Saale Tel.: +49 98 8306-0 E-Mail: kundenzentrum.hof@nexans.com www.nexans-power-accessories.com 0/0 Catalogue also available on CD-ROM