a Nexans company Catalogue 2015

Similar documents
Nexans Network Solutions Div. Euromold

a Nexans company Medium voltage symmetrical separable connectors - Interface C -

INTERFACE C MEDIUM VOLTAGE SYMMETRICAL SEPARABLE CONNECTORS CATALOGUE 2017

a Nexans company Catalogue 2009

THORNE & DERRICK UK TEL FAX TEL FAX

INTERFACE E - 5/8" MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

a Nexans company Catalogue 2007

a Nexans company Catalogue 2009

INTERFACE F MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

a Nexans company Catalogue 2012

a Nexans company Catalogue 2011

a Nexans company Catalogue 2006

Nexans Network Solutions Div. Euromold

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2007

a Nexans company Catalogue 2008

INTERFACE A MEDIUM VOLTAGE SEPARABLE CONNECTORS AND BUSHINGS CATALOGUE 2017

THORNE & DERRICK UK TEL FAX TEL FAX

a Nexans company Catalogue 2015

a Nexans company Catalogue 2009

Power cables accessories for use in potentially explosive atmospheres

Nexans Network Solutions Div. Euromold

ACCESSORIES. Application For use with connectors and bushings with an interface C as described by CENELEC EN and

Nexans Network Solutions Div. Euromold

a Nexans company Catalogue 2008

global leader in cables

Shielded surge arresters

High Voltage Accessories up to 72.5 kv

(K),(M)430TB/G Up to 36 kv

(K),(M),(P)489TB/G Up to 42 kv

a Nexans company Catalogue 2012

power cable accessories

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

ENERGIE - KABELGARNITUREN ACCESSOIRES POUR CÂBLES D ÉNERGIE

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

Cold-shrinkable Silicone 12 kv - 24 kv - 36 kv

H e a t s h r i n k P r o d u c t G u i d e

Energy Division. PCA Single Column Polymeric Surge Arrester

Power cable accessories catalogue


Separable Connectors and Kits

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

Medium Voltage. Joints & Terminations

Cellplux Plug-in Technology

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:


COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

Cable Accessories. Product Catalogue

NXPLUS C Single busbar. Maintenance-free for lifetime

Nexans Switzerland. Global expert in cables and cabling system. Cossonay Production Plant

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

Installation Instruction Heatshrink Termination For 3 Core Polymeric Cables 7.2kV to 36kV

TE S RAYCHEM RSTI-CC-58 SCREENED, SEPARABLE COUPLING SYSTEM

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

ABG Cable Glands Installation Procedure

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

22kV 425 AMP KA STYLE COUPLER 224BKA - Range

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Completing the picture

Nexans WINDLINK connection system. Nexans Power Accessories Germany GmbH

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

3 TM Cold Applied Barrier Boot System

Zinc Oxide Surge Arrester PEXLIM Q

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

INSTALLATION PRODUCTION TESTS

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Gas Insulated Switchgear

Direct-acting 3/2 way plunger valve

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Zinc-Oxide Surge Arrester TEXLIM Q-C

600 A 15 kv class T-OP II deadbreak connector

I nstallation I nstruction Heatshrink Term ination For 3 Core Polym eric Cables 7.2 kv to 3 6 kv

DURAREEL TRAILING REELING CABLE

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

M-0. M-0... series control, monitoring and signalling devices. Ex e

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

8DJ. Maintenance-free for lifetime

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

IEC Separable Connectors 17.5 kv/24 kv, 630A

Zinc Oxide Surge Arrester EXLIM R

Surge arrester POLIM-H..SD

ELASTIMOLD UNDERGROUND CABLE ACCESSORIES

QT-III Cold Shrink Silicone Rubber

600 A 35 kv class BT-TAP deadbreak connector

3EK7 Medium Voltage Silicone Insulated Surge Arresters

ELB ES. Product Installation Instructions

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Loadbreak Apparatus Connectors

Transcription:

a Nexans company Catalogue 2015

Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: premoulded EPDM rubber s for cables and epoxy bushings for transformers and switchgear, as well as a large range of coldshrinkable terminations and joints from 12 to 42 kv. Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group. ISO 9001 Certificate Since 1992, Euromold s commitment to quality is demonstrated by its ISO 9001 certification. International standards All our products meet the International standards like CENELEC HD 629.1, CENELEC EN 50180, IEC 60137, IEC 60502-4 or country specifications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are continuously performed in our test fields. Laboratory accreditation Since June 2000, Euromold s independent ELAB laboratory obtained the BELAC accreditation no.144-test conform with the European standards for laboratories ISO 17025 for electrical testing of low and medium voltage cable accessories according to the international standards EN 50393, IEC 60502-4, IEC 61442 and HD 629. While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as standards and technology evolve. /2013 1

SEPARABLE CONNECTORS INTERFACE C Table of contents 430TB - tee 484TB - tee 489TB - tee 300PBM - coupling 430TBM-P2/P3 - dual/triple cable arrangement 804PB - coupling 809PB - coupling 450SR - straight 300SA - surge arrester 800SA - surge arrester 400TR and 800TR - test rod 400TK and 400SW installation tools Accessories Possible arrangements T-HSTBK - Three core heat-shrink breakout kit Dia. 56 ±0.2 Dia. 46 ±0.2 Interface C1 & C2 Dimensions according to European CENELEC EN 50180 and 50181 (in mm). M16 x 2-6H Dia. 22 min for C1 Dia. 32 nominal for C2 0 1.5-0.5 29 min 90 ±0.2 11 min In mm. Dia. 70 ±0.2 /2013 2

Connecting possibilities BUSHINGS / ACCESSORIES CONNECTION CONNECTORS / ACCESSORIES Equipment interface dead-ending of equipment (K)(M)400DR-B Dead-end receptacle (K)(M)400AR-3 Equipment bushing (K)(M)400AR-4 Equipment bushing (K)(M)400AR-5 Equipment bushing cable to equipment (K)(M)430TB/G Tee (K)(M)300PBM/G Coupling (K)(M)400AR-6 Equipment bushing (K)(M)400SFR-B Equipment bushing 300SA Surge arrester 400A-24B In-air bushing (K)(M)400SOP-B Stand-off plug cable isolation (K)(M)484TB/G Tee (K)(M)804PB/G Coupling 400GP-B Earthing plug cable earthing (K)400RTPA Reducing tap plug tap-off /250A (K)(M)400CP-SC Connecting plug in-line junction 800SA Surge arrester For information on bushings please refer to our bushing catalogue. (K)(M)489TB/G Tee (K)(M)809PB/G Coupling (K)450SR Straight /2013 3

Application Separable tee shape (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors,...). Also connects cable to cable when using the appropriate mating parts. Technical characteristics A thick conductive EPDM jacket provides a total safe to touch screen. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. 430TB INTERFACE C TEE CONNECTOR Up to 36 kv A - A 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv Design Separable comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type C interface as described by CENELEC EN 50180 and 50181. 5.. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Clamping screw.. Earthing lead. 290 mm 4 9 5 1 2 3 185 mm 8 6 The screen break design enables cable outer sheath testing without removing or dismantling the. Specifications and standards The 430TB separable meets the requirements of CENELEC HD 629.1. 7 Separable type Voltage Um (kv) Current Ir (A) Current Ir (A) When using a copper (-11-2) or sizes (mm 2 ) a bolted (14-5) conductor contact and when installed on an appropriate equipment bushing min max 430TB/G K430TB/G M430TB/G 12 24 36 35 35 50 300 300 300 /2013 4

Kit contents The complete (K)(M)430TB/G tee kit comprises 3 x the following components: The kit also comprises silicone grease, field control mastic, installation rod, installation instructions and crimp chart. contact TMBC-X 3 x (K)(M)430TB/G-W-X kit Connector housing (K)(M)430BT/G Clamping screw 430TCS contact TBC-X Basic insulating plug (K)(M)300BIPA + rubber cap Cable reducer 430CA-W To order the tee, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv, add an 'M' for use up to 36 kv. Table W Table X Ordering part number 3 x 430TB/G-11-X 3 x 430TB/G-16-X 3 x 430TB/G-18-X 3 x 430TB/G-27-X 3 x 430TB/G-30-X Dia. over core insulation (mm) min 12.0 17.0 19.0 28.5 36.0 max 17.5 23.5 32.6 37.5 40.5 Example: The cable is 24 kv, 150 mm 2 compact stranded copper with a diameter over core insulation of 27.5 mm. Order 3 x K430TB/G-18-95.240-14-5 tee kit. sizes (mm 2 ) Aluminium conductor DIN hexagonal Deep indent Aluminium and copper conductor Bolted Copper conductor DIN hexagonal 35 35(K)M--2 35KM--1 35(K)M-11-2 50 50(K)M--2 50(K)M--1 50(K)M-11-2 70 70(K)M--2 70(K)M--1 70(K)M-11-2 95 95(K)M--2 95(K)M--1 95(K)M-11-2 120 120(K)M--2 120(K)M--1 120(K)M-11-2 150 150(K)M--2 150(K)M--1 150(K)M-11-2 185 185(K)M--2 185(K)M--1 185(K)M-11-2 240 240(K)M--2 240(K)M--1 240(K)M-11-2 300 300(K)M--2 300(K)M-11-2 16.95-14-5 50.150-14-5 95.240-14-5 120.300-14-5 For use with copper tape screened cables. Order: Kit MT. For use in potentially explosive atmospheres (for 12 kv max). Add -/ATEX to part number. Up to 24 kv this product can also be installed using a 300BIPR (without VD point) Order: BIPR. For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. This product can also be installed using a 411 CA. Please contact our representative. 5

Application Separable tee shape (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors,...). Also connects cable to cable when using the appropriate mating parts. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. 484TB INTERFACE C TEE CONNECTOR Up to 42 kv A - A 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv 20.8/36 (42) kv Design Separable comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type C - interface as described by CENELEC EN 50180 and 50181. 5.. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Clamping screw.. Earthing lead. 360 mm 4 9 5 1 2 3 185 mm 8 6 The screen break design enables cable outer sheath testing without removing or dismantling the. Specifications and standards The 484TB separable meets the requirements of CENELEC HD 629.1. 7 Separable type 484TB/G K484TB/G M484TB/G P484TB/G Voltage Um (kv) 12 24 36 42 Current Ir (A) When installed on an appropriate equipment bushing sizes (mm 2 ) min 50 35 35 35 max /2013 6

Kit contents The complete (K)(M)(P)484TB/G tee kit comprises 3x the following components: The kit also comprises silicone grease, field control mastic, gloves, roll adhesive tape, installation instructions and crimp chart. contact TMBC-X (K)(M)(P)484TB/G-W-X kit Connector housing (K)(M)(P)484BT/G Clamping screw 430TCS contact TBC-X Basic insulating plug (K)(M)(P)800BIPA + rubber cap Cable reducer 611CA-W To order the tee, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv, add an 'M' for use up to 36 kv, add a 'P' for use up to 42 kv. Table W Table X Ordering part number 3 x 484TB/G-15-X 3 x 484TB/G-19-X 3 x 484TB/G-22-X 3 x 484TB/G-27-X 3 x 484TB/G-32-X 3 x 484TB/G-37-X 3 x 484TB/G-43-X Dia. over core insulation (mm) min 16.0 20.0 23.5 28.5 34.0 39.0 45.5 max 22.0 26.5 31.0 37.5 42.5 48.5 56.0 Example: The copper wire screened cable is 36 kv, 240 mm 2 stranded aluminium with a diameter over core insulation of 37.0 mm. Order 3 x M484TB/G-32-240(K)M-12-2 tee kit. sizes (mm 2 ) 35 50 70 95 120 150 185 240 300 400 500 Aluminium conductor DIN hexagonal 35(K)M-12-2 50(K)M-12-2 70(K)M-12-2 95(K)M-12-2 120(K)M-12-2 150(K)M-12-2 185(K)M-12-2 240(K)M-12-2 300(K)M-12-2 400(K)M-12-2 500(K)M-12-2 Deep indent 35KM-12-1 50KM-12-1 70KM-12-1 95KM-12-1 120KM-12-1 150KM-12-1 185KM-12-1 240KM-12-1 300KM-12-1 400KM-12-1 500KM-12-1 KM-12-1 16.95-14-5 Aluminium and copper conductor 50.150-14-5 Bolted 95.240-14-5 120.300-14-5 185.400-14-5 400.-14-5 Copper conductor DIN hexagonal 35(K)M-11-2 50(K)M-11-2 70(K)M-11-2 95(K)M-11-2 120(K)M-11-2 150(K)M-11-2 185(K)M-11-2 240(K)M-11-2 300(K)M-11-2 400(K)M-11-2 500(K)M-11-2 (K)M-11-2 For use with copper tape screened cables. Order: Kit MT. For use with copper wire screened cables. No earthing device is necessary. For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. Components can be ordered individually. For use in potentially explosive atmospheres (for 12 kv max). Add -/ATEX to part number. 7

Application Separable tee shape (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switchgear, motors,...). Also connects cable to cable when using the appropriate mating parts. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. 489TB INTERFACE C TEE CONNECTOR Up to 42 kv A - A 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv 20.8/36 (42) kv Design Separable comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type C - interface as described by CENELEC EN 50180 and 50181. 5.. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Stud+nut.. Earthing lead. 460 mm 4 9 5 1 2 3 185 mm 8 6 The screen break design enables cable outer sheath testing without removing or dismantling the. 7 Specifications and standards The 489TB separable meets the requirements of CENELEC HD 629.1. Separable type 489TB/G K489TB/G M489TB/G P489TB/G Voltage Um (kv) 12 24 36 42 Current Ir (A) When installed on an appropriate equipment bushing sizes (mm 2 ) min max 1200 1200 1200 1200 /2013 8

Kit contents The complete (K)(M)(P)489TB/G tee kit comprises 3x the following components: The kit also comprises silicone grease, field control mastic, gloves, roll adhesive tape, installation instructions and crimp chart. contact TMBC-X (K)(M)(P)489TB/G-S-W-X kit Connector housing (K)(M)(P)489BT/G Stud+nut contact TBC-X Basic insulating plug (K)(M)(P)800BIPA + rubber cap Cable reducer 911CA-W To order the tee, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv, add an 'M' for use up to 36 kv, add a 'P' for use up to 42 kv. Table W Ordering part number 3 x 489TB/G-S-37-X 3 x 489TB/G-S-43-X 3 x 489TB/G-S-50-X 3 x 489TB/G-S-53-X 3 x 489TB/G-S-56-X 3 x 489TB/G-S-59-X Dia. over core insulation (mm) min 40 46 53 56 59 62 max 48 54 59 62 65 68 Example: The copper wire screened cable is 36 kv, 00 mm 2 stranded aluminium with a diameter over core insulation of 52 mm. Order 3 x M489TB/G-S-43-00(K) M-12-1 tee kit. Table X sizes (mm 2 ) 800 00 Aluminium conductor Deep indent KM-12-1 800KM-12-1 00KM-12-1 Aluminium and copper conductor Bolted 400.-14-5 800.00-14-5 Copper conductor DIN hexagonal (K)M-11-2 800(K)M-11-2 00(K)M-11-2 1200 1200KM-12-1 - - For use with copper tape screened cables. Order: Kit MT. For use with copper wire screened cables. No earthing device is necessary. For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. Components can be ordered individually. When installed on an appropriate equipment bushing: A continuously 9

Application Separable coupling (bolted type) for dual cable arrangement. It has been designed to be used with 430TB separable tee. Technical characteristics A thick conductive EPDM jacket provides a total safe to touch screen. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. 300PBM COUPLING CONNECTOR FOR 430TB Up to 36 kv 800 A 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv Design 1. Interface designed to fit 430TB. 2. Bus for 300PBM. 3. Conductive EPDM insert. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Conductive EPDM jacket. 6. Conductive EPDM cap. 7. Basic insulating plug (with VD point). 8. (hexagonal crimping, deep indent crimping or bolted). 9. Cable reducer.. Earthing lead. The screen break design enables cable outer sheath testing without removing or dismantling the. 290 mm 1 430TB 290 mm 2 8 3 4 5 6 7 300PBM coupling Specifications and standards The 300PBM coupling meets the requirements of CENELEC HD 629.1. 9 5 mm Separable type Voltage Um (kv) Current Ir (A) sizes (mm 2 ) min max 300PBM/G K300PBM/G M300PBM/G 12 24 36 800 800 800 35 35 50 300 300 240 /2013

Kit contents The complete (K)(M)300PBM/G coupling kit comprises 3 x the following components: The kit also comprises silicone grease, field control mastic, installation rod, installation instructions and crimp chart. contact TMBC-X 3 x (K)(M)300PBM/G-W-X coupling kit Cable reducer 430CA-W Connector housing (K)(M)300BP/G Contact rod 300PB-CR contact TBC-X To order the coupling, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv, add an 'M' for use up to 36 kv. Table W Ordering part number 3 x 300PBM/G-11-X 3 x 300PBM/G-16-X 3 x 300PBM/G-18-X 3 x 300PBM/G-27-X Dia. over core insulation (mm) min 12.0 17.0 19.0 28.5 max 17.5 23.5 32.6 37.5 Example: The cable is 24 kv, 150 mm 2 compact stranded copper with a diameter over core insulation of 27.5 mm. Order 3 x K300PBM/G-18-95.240-14-5 coupling kit. Table X sizes (mm 2 ) Aluminium conductor DIN hexagonal Deep indent Aluminium and copper conductor Bolted Copper conductor DIN hexagonal 35 35(K)M--2 35KM--1 35(K)M-11-2 50 50(K)M--2 50(K)M--1 50(K)M-11-2 70 70(K)M--2 70(K)M--1 70(K)M-11-2 95 95(K)M--2 95(K)M--1 95(K)M-11-2 120 120(K)M--2 120(K)M--1 120(K)M-11-2 150 150(K)M--2 150(K)M--1 150(K)M-11-2 185 185(K)M--2 185(K)M--1 185(K)M-11-2 240 240(K)M--2 240(K)M--1 240(K)M-11-2 300 300(K)M--2 300(K)M-11-2 16.95-14-5 50.150-14-5 95.240-14-5 120.300-14-5 For use with copper tape screened cables. Order: Kit MT. For use in potentially explosive atmospheres (for 12 kv max). Add -/ATEX to part number. For use with copper wire screened cables. No earthing device is necessary. For use with other cable types. Please contact our representative. For outdoor applications. Order: +MWS. This product can also be installed using a 411 CA. Please contact our representative. 11

Application Separable s (bolted type) for dual (P2) and triple (P3) cable arrangements. Technical characteristics A thick conductive EPDM jacket provides a total safe to touch screen. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. 430TBM-P2/P3 DUAL/TRIPLE CABLE ARRANGEMENT FOR 430TB CONNECTOR Up to 36 kv A - A 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv Design 1. Type C interface as described by CENELEC EN 50180 and 50181. 2. Bus for 300PBM. 3. Conductive EPDM insert. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Conductive EPDM jacket. 6. Conductive EPDM cap. 7. Basic insulating plug (with VD point). 8.. 9. Cable reducer.. Earthing lead. The screen break design enables cable outer sheath testing without removing or dismantling the. Specifications and standards The 430TBM-P2/P3 s meet the requirements of CENELEC HD 629.1. 1 Non-size sensitive: 290 mm 430TB 290 mm 2 8 3 4 5 9 5 mm 6 7 300PBM coupling Separable type Voltage Um (kv) Current Ir (A) Current Ir (A) When using a copper (-11-2) or sizes (mm 2 ) a bolted (14-5) conductor contact and when installed on an appropriate equipment bushing min max 430TBM-P2/P3 K430TBM-P2/P3 M430TBM-P2/P3 12 24 36 35 35 50 300 300 240 /2013 12

Kit contents The complete (K)(M)430TBM-P2 kit comprises 3 x the following components: 290 300BIPA basic insulating plug 300PBM coupling 430TB tee The complete (K)(M)430TBM-P3 kit comprises 3 x the following components: 395 300BIPA basic insulating plug 300PBM coupling s 430TB tee 1 5 1 5 5 In mm. To order the separable s for dual cable arrangement, use the tables beside to substitute for W and X in the formula: 3 x 430TBM-P2-W-X, for use up to 12 kv. Add a 'K' for use up to 24 kv: 3 x K430TBM-P2-W-X. Add an 'M' for use up to 36 kv: 3 x M430TBM-P2-W-X. 1. From table W: select the symbol which gives the best centring of your core insulation diameter. 2. From table X: according to your conductor size and type, select the designation which completes the part number. Table X Table W Dia. over core insulation (mm) min 12.0 17.0 19.0 28.5 max 17.5 23.5 32.6 37.5 W 11 16 18 27 For triple cable arrangement: 3 x 430TBM-P3-W-X, for use up to 12 kv. Add a 'K' for use up to 24 kv: 3 x K430TBM-P3-W-X. Add an 'M' for use up to 36 kv: 3 x M430TBM-P3-W-X. Example: The two cables are 24 kv, 150 mm 2 stranded aluminium with a diameter over core insulation of 27.5 mm. Order 3 x K430TBM-P2-18- 150(K)M--2. sizes (mm 2 ) Aluminium conductor DIN hexagonal Deep indent Aluminium and copper conductor Bolted Copper conductor DIN hexagonal 35 35(K)M--2 35KM--1 35(K)M-11-2 50 50(K)M--2 50(K)M--1 50(K)M-11-2 70 70(K)M--2 70(K)M--1 70(K)M-11-2 95 95(K)M--2 95(K)M--1 95(K)M-11-2 120 120(K)M--2 120(K)M--1 120(K)M-11-2 150 150(K)M--2 150(K)M--1 150(K)M-11-2 185 185(K)M--2 185(K)M--1 185(K)M-11-2 240 240(K)M--2 240(K)M--1 240(K)M-11-2 300 300(K)M--2 300(K)M-11-2 16.95-14-5 50.150-14-5 95.240-14-5 120.300-14-5 For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-226 cables. Please contact our representative. For use with other cable types. Please contact our representative. Up to 24 kv this product can also be installed using a 300BIPR (without VD point) Order: BIPR. For applications outdoors and in humid climate. Order: +MWS. For use in potentially explosive atmospheres (for 12 kv max). Add -/ATEX to part number. 13

Application Separable coupling (bolted type) for dual cable arrangement. It has been designed to be used with 484TB and 489TB separable tee s. Technical characteristics A thick conductive EPDM jacket provides a total safe to touch screen. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. 804PB COUPLING CONNECTOR FOR 484TB/G Up to 42 kv A 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv 20.8/36 (42) kv Design 1. Interface designed to fit 484TB and 489TB. 2. Bus for 804PB. 3. (hexagonal crimping, deep indent crimping or bolted). 4. Conductive EPDM insert. 5. Conductive EPDM jacket. 6. Insulating EPDM layer moulded between the insert and the jacket. 7. Cable reducer. 8. Conductive EPDM cap. 9. Basic insulating plug (with VD point).. Earth lead. The screen break design enables cable outer sheath testing without removing or dismantling the. Specifications and standards The 804PB coupling meets the requirements of CENELEC HD 629.1. Separable type 804PB/G K804PB/G M804PB/G P804PB/G Voltage Um (kv) 12 24 36 42 Current Ir (A) sizes (mm 2 ) min 50 35 35 35 max /2013 14

Kit contents The complete (K)(M)(P)804PB/G coupling kit comprises 3 x the following components: The kit also comprises silicone grease, field control mastic, gloves, roll adhesive tape, installation instructions and crimp chart. contact TMBC-X 3 x (K)(M)(P)804PB/G-W-X coupling kit Connector housing (K)(M)(P)804BP/G Contact rod and stud contact TBC-X Cable reducer 611CA-W To order the coupling, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv, add an 'M' for use up to 36 kv, add a 'P' for use up to 42 kv. Table W Table X Ordering part number 3 x 804PB/G-15-X 3 x 804PB/G-19-X 3 x 804PB/G-22-X 3 x 804PB/G-27-X 3 x 804PB/G-32-X 3 x 804PB/G-37-X 3 x 804PB/G-43-X Dia. over core insulation (mm) min 16.0 20.0 23.5 28.5 34.0 39.0 45.5 max 22.0 26.5 31.0 37.5 42.5 48.5 56.0 Example: The copper wire screened cable is 36 kv, 240 mm 2 stranded aluminium with a diameter over core insulation of 37.0 mm. Order 3 x M804PB/G-32-240(K)M-12-2 coupling kit. sizes (mm 2 ) 35 50 70 95 120 150 185 240 300 400 500 Aluminium conductor DIN hexagonal 35(K)M-12-2 50(K)M-12-2 70(K)M-12-2 95(K)M-12-2 120(K)M-12-2 150(K)M-12-2 185(K)M-12-2 240(K)M-12-2 300(K)M-12-2 400(K)M-12-2 500(K)M-12-2 Deep indent 35KM-12-1 50KM-12-1 70KM-12-1 95KM-12-1 120KM-12-1 150KM-12-1 185KM-12-1 240KM-12-1 300KM-12-1 400KM-12-1 500KM-12-1 KM-12-1 16.95-14-5 Aluminium and copper conductor 50.150-14-5 Bolted 95.240-14-5 120.300-14-5 185.400-14-5 400.-14-5 Copper conductor DIN hexagonal 35(K)M-11-2 50(K)M-11-2 70(K)M-11-2 95(K)M-11-2 120(K)M-11-2 150(K)M-11-2 185(K)M-11-2 240(K)M-11-2 300(K)M-11-2 400(K)M-11-2 500(K)M-11-2 (K)M-11-2 For use with copper tape screened cables. Order: Kit MT. For use with copper wire screened cables. No earthing device is necessary. For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. Components can be ordered individually. For use in potentially explosive atmospheres (for 12 kv max). Add -/ATEX to part number. 15

809PB COUPLING CONNECTOR FOR 484TB/G AND 489TB/G Application Separable coupling (bolted type) for dual cable arrangement. It has been designed to be used with 484TB and 489TB separable tee s. Technical characteristics A thick conductive EPDM jacket provides a total safe to touch screen. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. Up to 42 kv A 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv 20.8/36 (42) kv Design 1. Interface designed to fit 484TB and 489TB. 2. Bus for 809PB. 3. (hexagonal crimping, deep indent crimping or bolted). 4. Conductive EPDM insert. 5. Conductive EPDM jacket. 6. Insulating EPDM layer moulded between the insert and the jacket. 7. Cable reducer. 8. Conductive EPDM cap. 9. Basic insulating plug (with VD point).. Earth lead. The screen break design enables cable outer sheath testing without removing or dismantling the. Specifications and standards The 809PB coupling meets the requirements of CENELEC HD 629.1. Separable type 809PB/G K809PB/G M809PB/G P809PB/G Voltage Um (kv) 12 24 36 42 Current Ir (A) sizes (mm 2 ) min max 1200 1200 1200 1200 /2013 16

Kit contents The complete (K)(M)(P)809PB/G coupling kit comprises 3 x the following components: The kit also comprises silicone grease, field control mastic, gloves, roll adhesive tape, installation instructions and crimp chart. contact TMBC-X 3 x (K)(M)(P)809PB/G-S-W-X coupling kit Connector housing (K)(M)(P)809BP/G Contact rod and stud contact TBC-X Cable reducer 911CA-W To order the coupling, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv, add an 'M' for use up to 36 kv, add a 'P' for use up to 42 kv. Table W Table X Ordering part number 3 x 809PB/G-S-37-X 3 x 809PB/G-S-43-X 3 x 809PB/G-S-50-X 3 x 809PB/G-S-53-X 3 x 809PB/G-S-56-X 3 x 809PB/G-S-59-X Dia. over core insulation (mm) min 40 46 53 56 59 62 max 48 54 59 62 65 68 Example: The copper wire screened cable is 36 kv, 00 mm 2 stranded aluminium with a diameter over core insulation of 52 mm. Order 3 x M809PB/G-S-43-00(K)M-12-1 coupling kit. sizes (mm 2 ) 800 00 1200 Aluminium conductor Deep indent KM-12-1 800KM-12-1 00KM-12-1 1200KM-12-1 Aluminium and copper conductor Bolted 400.-14-5 800.00-14-5 - Copper conductor DIN hexagonal (K)M-11-2 800(K)M-11-2 00(K)M-11-2 - For use with copper tape screened cables. Order: Kit MT. For use with copper wire screened cables. No earthing device is necessary. For use with Alupe or C 33-226 cables. Please contact our representative. For use with other cable types. Please contact our representative. For applications outdoors and in humid climate. Order: +MWS. Components can be ordered individually. 17

Application Separable straight designed to connect polymeric insulated cable to equipment (transformers, switch gear, motors...). Also connects cable to cable, using the appropriate mating part. Technical characteristics The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. Each separable is tested for AC withstand and partial discharge prior to leaving the factory. 450SR INTERFACE C STRAIGHT CONNECTOR Up to 24 kv - A 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv Design Separable comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type C - A interface as described by CENELEC EN 50180 and 50181. 5. assembly. 6. Retaining ring. 7. Cable reducer. 4 1 2 5 6 3 7 380 mm Specifications and standards The separable 450SR meets the requirements of CENELEC HD 629.1 S1. Dia. 78 mm Separable type Voltage Um (kv) Current Ir (A) size (mm 2 ) min. max. 450SR K450SR 12 24 50 25 300 300 /2013 18

Kit contents The complete (K)450SR straight kit comprises the following components: The kit also comprises lubricant, wipers, installation instructions and crimp chart. Type 1 + + + or + + = (K)450SR-W-X+11TL kit Type 2 Connector housing (K)450SRH Locking disc 450SRD Retaining ring + hex key 400RR-X Contact assembly 450SRC-X-Assy Cable reducer 450CA-W Cable adaptor 11TL To order the straight, select the ordering part number which gives you the best centring of your core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kv. Table W Ordering part number 450SR-06-X+11TL 450SR-08-X+11TL 450SR--X+11TL 450SR-12-X+11TL 450SR-14-X+11TL Dia. over core insulation (mm) min. max. 16.5 21.5 19.9 24.4 23.2 28.0 26.1 31.0 30.0 36.1 Table X size (mm 2 ) contact type (DIN standards only) Type 1 Type 2 Aluminium Copper Aluminium Copper Example: The copper wire screened cables are 24 kv, 240 mm 2 stranded aluminium with a diameter over core insulation of 32.2 mm. Order 3 x K450SR-14-240KM- 12-2+11TL straight kit. 25 35 50 70 95 120 150 185 240 300 35KM-12-2 50KM-12-2 70KM-12-2 95KM-12-2 120KM-12-2 150KM-12-2 185KM-12-2 240KM-12-2 300KM-12-2 25KM-11-2 35KM-11-2 50KM-11-2 70KM-11-2 95KM-11-2 120KM-11-2 150KM-11-2 185KM-11-2 240KM-11-2 300KM-11-2 35KM-12-2-L 50KM-12-2-L 70KM-12-2-L 95KM-12-2-L 120KM-12-2-L 35KM-11-2-L 50KM-11-2-L 70KM-11-2-L 95KM-11-2-L 120KM-11-2-L For use with copper tape screened cables. Order: Kit MT. For use with Alupe or C 33-226 cables. Please contact our representative. For use with fabric tape (graphite) screened cables. Order additional semi-conductive tape (type TSC). For use with other cable types. Please contact our representative. For outdoor applications. Order: +MWS. Components can be ordered individually. 19

Application Surge arrester designed to protect 12, 24 and 36 kv class components, including transformers, equipment, cable and accessories from high voltage surges resulting from lightning or switching. It has been designed to be used with the 430TB separable tee. Technical characteristics This surge arrester is a metal oxide varistor surge arrester in an elbow configuration. Each arrester is tested for AC withstand, partial discharge and critical voltage prior to leaving the factory. 300SA SURGE ARRESTER FOR 430TB CONNECTOR Up to 36 kv 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv Design Surge arrester comprising: 1. Interface designed to fit the 430TB tee. 2. Conductive EPDM insert. 3. Conductive EPDM jacket. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Receptacle for contact rod. 6. Metal oxide valve elements. 7. Steel cap. 8. Earth connection. 9. Earth lead. L2 L1 1 5 2 3 4 170 mm 5 mm Dia. 75 mm 9 6 Specifications and standards The 300SA surge arresters meet the test requirements of IEC 60099-4. 7 8 Dia. 65 mm Surge arrester type Nominal discharge current In (ka) Rated voltage Ur (kv) Max. continuous operating voltage Uc (kv) L1 Dimensions (mm) L2 300SA--6N 300SA--9N 300SA--12N 300SA--15N 300SA--18N 300SA--22N 300SA--24N 300SA--30N 300SA--33N 300SA--36N 300SA--45N 300SA--51N 6 9 12 15 18 22 24 30 33 36 45 51 4.8 7.2 9.6 12.0 14.4 17.6 19.2 24.0 26.4 28.8 36.0 40.8 250 250 250 250 250 250 350 350 350 350 450 450 290 290 290 290 290 290 390 390 390 390 490 490 /2013 20

Typical application and dimensions 290 mm 180 mm 7 mm To order the surge arrester, specify the surge arrester type, as described on previous page. Example: For a maximum continuous operating voltage (r.m.s.) of 24 kv and a nominal discharge current of ka. Order a 300SA--30N surge arrester. Type 300SA surge arrester Type 430TB tee Note: the surge arrester body needs to be positioned vertically after installation. For use in potentially explosive atmospheres (for 12 kv max). Add -/ATEX to part number. Technical data Surge arrester type Steep current residual voltage @ ka [1/20 µs] (kv) Lightning current residual voltage [8/20 µs] (kv) Switching impulse residual voltage [36/90 µs] (kv) @ 5 ka @ ka @ 20 ka @ 125 A @ 500 A High current impulse withstand (ka) 300SA--6N 300SA--9N 300SA--12N 300SA--15N 300SA--18N 300SA--22N 300SA--24N 300SA--30N 300SA--33N 300SA--36N 300SA--45N 300SA--51N 20.4 28.5 38.0 48.1 58.1 70.1 77.0 97.0 6.3 115.9 144.1 166.0 16.8 23.5 31.4 39.7 48.0 57.9 63.6 80.1 83.1 95.7 119.0 137.1 18.3 25.6 34.2 43.2 52.2 63.0 69.2 87.2 90.5 4.2 129.5 149.2 20.5 28.7 38.3 48.4 58.5 70.6 77.6 97.7 1.4 116.8 145.1 167.2 12.9 18.0 24.1 30.5 36.8 44.4 48.8 61.5 63.8 73.5 91.3 5.2 13.7 19.2 25.7 32.5 39.2 47.3 52.0 65.5 68.0 78.3 97.3 112.1 0 0 0 0 0 0 0 0 0 0 0 0 21

Application Surge arrester designed to protect 12, 24, 36 and 42 kv class components, including transformers, equipment, cable and accessories from high voltage surges resulting from lightning or switching. It has been designed to be used with the 484TB and 489TB separable tee s. Technical characteristics This surge arrester is a metal oxide varistor surge arrester in an elbow configuration. Each arrester is tested for AC withstand, partial discharge and critical voltage prior to leaving the factory. 800SA SURGE ARRESTER FOR 484TB CONNECTOR Up to 42 kv 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv 20.8/36 (42) kv Design Surge arrester comprising: 1. Interface designed to fit the 484TB and 489TB tee. 2. Conductive EPDM insert. 3. Conductive EPDM jacket. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Receptacle for contact rod. 6. Metal oxide valve elements. 7. Steel cap. 8. Earth connection. 9. Earth lead. L2 1 5 2 170 mm 5 mm Dia. 75 mm 3 L1 9 4 Specifications and standards The 800SA surge arresters meet the test requirements of IEC 60099-4. 6 7 8 Dia. 65 mm Surge arrester type Nominal discharge current In (ka) Rated voltage Ur (kv) Max. continuous operating voltage Uc (kv) L1 Dimensions (mm) L2 800SA--15N 800SA--18N 800SA--22N 800SA--24N 800SA--30N 800SA--33N 800SA--36N 800SA--45N 800SA--51N 15 18 22 24 30 33 36 45 51 12.0 14.4 17.6 19.2 24.0 26.4 28.8 36.0 40.8 250 250 250 350 350 350 350 450 450 290 290 290 390 390 390 390 490 490 /2013 22

Typical application and dimensions 290 mm 180 mm 1 mm To order the surge arrester, specify the surge arrester type, as described on previous page. Example: For a maximum continuous operating voltage (r.m.s.) of 24 kv and a nominal discharge current of ka. Order a 800SA--30N surge arrester. Type 484TB tee Type 800SA surge arrester Note: the surge arrester body needs to be positioned vertically after installation. For use in potentially explosive atmospheres (for 12 kv max). Add -/ATEX to part number. Technical data Surge arrester type Steep current residual voltage @ ka [1/20 µs] (kv) Lightning current residual voltage [8/20 µs] (kv) Switching impulse residual voltage [36/90 µs] (kv) @ 5 ka @ ka @ 20 ka @ 125 A @ 500 A High current impulse withstand (ka) 800SA--15N 800SA--18N 800SA--22N 800SA--24N 800SA--30N 800SA--33N 800SA--36N 800SA--45N 800SA--51N 48.1 58.1 70.1 77.0 97.0 6.3 115.9 144.1 166.0 39.7 48.0 57.9 63.6 80.1 83.1 95.7 119.0 137.1 43.2 52.2 63.0 69.2 87.2 90.5 4.2 129.5 149.2 48.4 58.5 70.6 77.6 97.7 1.4 116.8 145.1 167.2 30.5 36.8 44.4 48.8 61.5 63.8 73.5 91.3 5.2 32.5 39.2 47.3 52.0 65.5 68.0 78.3 97.3 112.1 0 0 0 0 0 0 0 0 0 23

400TR and 800TR INTERFACE C TEST RODS Application The test rod can be used for: - cable fault location - cable testing - phasing checks, etc. Connections may be made with a cable lug, a 4 mm plug or spring clips. Technical characteristics The 400TR test rod can be used with 430TB s. The 800TR is for use with the 484TB. Design 1. Insulating shroud. 2. Threaded rod for test connection. 3. Two nuts M12. 4. Insulation. 5. Copper test rod stem. 400TR 800TR An insulating shroud is provided to allow the application of test voltages when bushings are closely spaced. 1 2 3 M12 40 1 2 3 M12 Installation The test rod is mounted on to the clamping screw in the type C interface tee and coupling s. The test cable is connected to the threaded stem and the insulating shroud moved to its final position over the end of the test rod. 4 288 5 480 4 5 321,5 480 Simply specify: 400TR or 800TR test rod. In mm. Test rod type Maximum A.C. test voltage (50 Hz - 1 min) Maximum D.C. test voltage (8 x U 0-30 min) Impulse voltage (1.2 x 50 µs) min 400TR 800TR 36 kv 36 kv 96 kv 96 kv 95 kv 95 kv /2013 24

400TK and 400SW INSTALLATION TOOL Application The box spanner and box spanner key are designed to facilitate assembly of 400TE, 400TB and 440TB s. The 400TK box spanner is used to install the 400TEF clamping pin contact or 400TCS clamping screw. The 400SW box spanner key fits on the hex nut of the 400BIPA basic insulating plug. 400TK 400SW Simply specify: - 400TK box spanner - 400SW box spanner key 03/2013 25

ACCESSORIES INTERFACE C Application For use with s and bushings with an interface C as described by CENELEC EN 50180 and 50181. 400DR-B/G Dead-end receptacle Fits over a bushing with a type C interface to provide 'deadend' facility. The dead-end receptacle is supplied with an earth lead. Technical characteristics All these products, except the earthing plugs, are tested for AC withstand and partial discharge prior to leaving the factory. Up to 36 kv 6/ (12) kv 6.35/11 (12) kv 8.7/15 (17.5) kv 12/20 (24) kv 12.7/22 (24) kv 18/30 (36) kv 19/33 (36) kv 20,8/36 (42) kv Order 400DR-B/G for 12 kv, K400DR-B/G for 24 kv or M400DR-B/G for 36 kv applications. 400SOP-B Stand-off plug Is designed to support and 'dead-end' s with a type C interface when removed from equipment. Order 400SOP-B for 12 kv, K400SOP-B for 24 kv, M400SOP-B for 36 kv or P400SOP-B for 42 kv applications. 400GP-B Earthing plug Is designed to support and earth s with a type C interface when removed from equipment. Order 400GP-B for 12, 24, 36 or 42 kv applications. Order 400GP-SBT for a version with a straight bolt terminal. /2013 26

300GP-B Earthing plug Is designed to earth the 430TB, 300PB s when it is fixed-mounted to the equipment (maintenance earthing). Order 300GP-B for 12, 24 or 36 kv applications. Order 300GP-SBT for a version with a straight ball terminal. 800GP-B Earthing plug Is designed to earth the 484TB and 804PB s when it is fixed-mounted to the equipment (maintenance earthing). Order 800GP-B for 12, 24, 36 or 42 kv applications. Order 800GP-SBT for a version with a straight ball terminal. 400BIPA Basic insulating plug Acts as a tightening nut for the 400TB and 440TB tee kits. The plug contains a voltage detection point. The conductive rubber protection cap is included. Order 400BIPA for 12 kv, K400BIPA for 24 kv M400BIPA for 36 kv or P400BIPA for 42 kv applications. Kit MT Earthing kit for copper tape screened cables Contains a tinned copper braid (25 mm² - L = 500 mm), a tinned copper wire for cleating and some water sealing mastic. Order Kit MT for 12 kv, 24 kv, 36 kv or 42 kv applications. 27

POSSIBLE ARRANGEMENTS INTERFACE C 430TB Single cable arrangement. Order 430TB for 12 kv, K430TB for 24 kv or M430TB for 36 kv applications. 185 300BIPA basic insulating plug 430TB tee 430TBM-P2 Dual cable arrangement. Order 430TBM-P2 for 12 kv, K430TBM-P2 for 24 kv or M430TBM-P2 for 36 kv applications. 290 300BIPA basic insulating plug 300PBM coupling 430TB tee 1 1 5 430TBM-P3 Triple cable arrangement. Order 430TBM-P3 for 12 kv, K430TBM-P3 for 24 kv or M430TBM-P3 for 36 kv applications. 430TBM-L3 3-way connection. Order 430TBM-L3 for 12 kv, K430TBM-L3 for 24 kv or M430TBM-L3 for 36 kv applications. 395 425 300BIPA basic insulating plug 300PBM coupling s 400BIPA basic insulating plug 300BIPA basic insulating plug 300PBM coupling s 430TB tee 430TB tee 1 5 5 In mm. /2013 28

484TB Single cable arrangement. Order 484TB for 12 kv, K484TB for 24 kv, M484TB for 36 kv or P484TB for 42 kv applications. 185 800BIPA basic insulating plug 484TB-P2 Dual cable arrangement. Order 484TB-P2 for 12 kv, K484TB-P2 for 24 kv or M484TB-P2 for 36 kv or P484TB-P2 for 42kV applications. 290 800BIPA basic insulating plug 484TB tee 804PB coupling 1 1 1 484TB tee 484TB-P2 + 800SA Dual cable arrangement with surge arrester. Order 484TB-P2+800SA for 12 kv, K484TB-P2+800SA for 24 kv, M484TB-P2+800SA for 36 kv or P484TB-P2+800SA for 42 kv applications. 400 800BIPA basic insulating plug 800SA surge arrester 1 1 484TB tee 804PB coupling In mm. 29

489TB Single cable arrangement. Order 489TB for 12 kv, K489TB for 24 kv, M489TB for 36 kv or P484TB for 42 kv applications. 185 489TB-P2 Dual cable arrangement. Order 489TB-P2 for 12 kv, K489TB-P2 for 24 kv or M489TB-P2 for 36 kv or P489TB-P2 for 42kV applications. 800BIPA basic insulating plug 489TB tee 1 In mm. 30

Earthing plug on Order 300GP-B for 12 kv, 24 kv and 36 kv applications. Order 800GP-B for 12 kv, 24 kv, 36 kv or 42 kv applications. 800GP-B earthing plug 484TB tee Cable and equipment testing 800TR test rod insulating shroud 484TB tee 1 In mm. 31

T-HSBK THREE CORE HEAT-SHRINK BREAKOUT KIT Application For sealing of three core polymeric insulated cable crutches and earthing of the metallic screens and armour. For use with Euromold separable s with ground lead (/G) or with terminations. Technical characteristics The installed breakout fullfills the requirements of IP54. The armouring and screen connection systems have short circuit rating (Isc) of up to 5,1 ka/1s. Design The three core heat-shrink breakout kit consists of (depending on cable type): a heat-shrinkable breakout, 3 sleeves of 500 mm, earth braid and roll springs, hose clamp, water sealing mastic and installation instructions. To order the 3-core kit, select the part number, which gives you the best centering over the cable core insulation diameter and substitute X using table X, according to your cable type. For tail lengths up to 700 mm Ordering part number Typical use sizes (mm²) 12, 17 & 24 kv 36 kv Diameter over core isolation (mm) Diameter over armour (mm) T-HSBK-20-X 16-95 - 12-23 50-70 T-HSBK-30-X 95-240 16-95 19-31 60-80 T-HSBK-40-X 185-400 95-240 24-35 70-90 T-HSBK-50-X - 185-400 32-40 80-0 Table X X depending on cable type X Unarmoured, individual copper tape screen Unarmoured, individual copper wire screen Unarmoured, common copper wire screen Armoured, individual copper tape or wire screen Armoured, common copper wire screen DR1K DR2K DR3K DR1F/DR2F DR3F /2013 32

Additional catalogue information on power cable accessories is available by contacting us at the address below: Distributed by: a Nexans company Nexans Network Solutions N.V. - Div. Euromold Zuid III, Industrielaan 12, B-9320 Erembodegem Tel.: +32 (0)53 85 02 11 sales.euromold@nexans.com www.euromold.be 05/2015 Catalogue also available on CD-ROM, Website and Mobile Apps