Catalog HY13-1552-001/N,EU Vertical ower Units Volume Control Hydraulic ower Units D, H and V-ak Series Catalog 2600-500-1/US 15 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Vertical ower Units Volume Control 16 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Introduction Vertical ower Units Volume Series D, Control H, V-aks Quick Reference Data Chart ump ank Size ump Flow Electrical Maximum * Model No. Gallon (Liters) GM (LM) @ 1725 RM Motors SI (ar) D-aks 5 (18.9) 0.9-2.7 (2.2-10.2).5 H.. - 3 H.. 3000 (207) H-aks 10 (37.9), 20 (75.7), 30 (113.6), 40 (151.4) 0.9-12.7 (2.2-48.0).5 H.. - 20 H.. 3000 (207) V-aks 10 (37.9), 20 (75.7), 30 (113.6), 40 (151.4) 2.0-15.6 (7.6-59.1) 2 H.. - 20 H.. 3000 (207) * See pump/motor combination, maximum pressure charts. 17 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU echnical Information Vertical ower Units Volume Series D, Control H, V-aks Warranty he hydraulic components on these arker ower Units are warranteed for one year. his warranty may be extended to two years by using and properly maintaining arker filters. Installation Data: See Installation/Maintenance Manual for specific recommendations pertaining to start-up, system cleanliness, fluids, temperature and other important factors relative to proper installation and use of these power units. Standard Features Vertical Design Submerged ump Spare Return orts recision ump Mounting dapters Suction Strainer Glycerine Filled ressure Gage with Shut Off Oil Level Gage with hermometer Relief Valve reather and Fill Cap SE Drain lug arker Connector echnology Schematic Symbol (Hydraulic Schematic - asic Unit) O OION MNIFOLD enefits Saves Floor Space Quieter Operation, Elimination of otential Leak oint Longer ump Life rotects ump from Contamination Improved Diagnostics Helps to Maintain rouble-free erformance rotects gainst System Shock Easy o Fill Reservoir revents Leaks O OION MNIFOLD SE -12 M SRE REURN D & H-K SIC UNI NO OIONS OR CCESSORIES O OION MNIFOLD SE -12 M OMI OION COM CONROL SRE REURN V-K SIC UNI NO OIONS OR CCESSORIES OMI OION UM COMENSOR O OION MNIFOLD 18 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Installation Information Vertical ower Units Volume Series D-aks Control Dimensions - asic D-ak (5 Gallon ank) Millimeter equivalents for inch dimensions are shown in (**). Option Reference SRE REURN OR 1/2" NF WIH DRO IE.75 (19.1) 1.25 (31.8) 15.0 (381.0) 13.5 (342.9) 12.5 (317.5).56 DI. MOUNING HOLES - 4 LCES 10.0 (254.0) SRE REURN OR 1/2" NF WIH DRO IE ELECRIC MOOR O & S3 OION MNIFOLD ( & LOCK & D03 SINGLE SION) SHOWN WIH OION O REURN FILER 12.5 (317.5) SYSEM RELIEF VLVE.9 (22.9) O & S3 OION MNIFOLD ( & LOCK & D03 SINGLE SION) SIC UNI RESSURE GGE WIH NEEDLE VLVE SRE REURN OR 1/2" NF WIH DRO IE O ( & LOCK) OR S3 ( D03 SULE) SHOWN-SEE MNIFOLD OIONS FILLER REHER 10.36 (263.1) 1.5 (38.1) 12.12 (307.9) OIL LEVEL SIGH GGE NK DRIN SE-12 (LUGGED).12 (3.1) M3* OION MNIFOLD (MULI-SION D03 MNIFOLD) SHOWN WIH OION O REURN FILER Motor Motor Description Dimension H-RM-Frame-hase G U1.5-1725-145CZ-1 10.62 (269.75) C1.75-1725-145CZ-1 11.62 (295.15) 1 1-1725-145CZ-1 11.62 (295.15) 3 1-1725-145CZ-3 10.18 (258.57) F 1.5-1725-145CZ-3 11.18 (283.97) G 2-1725-145CZ-3 12.06 (306.32) K 3-1725-145CZ-3 13.44 (341.38) 19 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Installation Information Vertical ower Units Volume Series H, Control V-aks Dimensions - asic H1 & V1 (10 Gallon ank) Millimeter equivalents for inch dimensions are shown in (**)..75 (19.1) 1.31 (33.3) 19.00 (482.6) 17.50 (444.5) 16.63 (422.4).56 DI. MOUNING HOLES - 4 LCES Option Reference SRE REURN OR 3/4" NF WIH DRO IE SRE REURN OR 3/4" NF WIH DRO IE 14.00 (355.6) ELECRIC MOOR 16.63 (422.4) SYSEM RELIEF VLVE FOR H-KS SFEY RELIEF VLVE FOR V-KS O & S5 OION MNIFOLD ( & LOCK & D05 SINGLE SION) SHOWN WIH OION O REURN FILER.9 (22.9) O & S5 OION MNIFOLD ( & LOCK & D05 SINGLE SION) SIC UNI UM COMENSOR CONROL FOR V-KS (NO INCLUDED ON H-KS) ROION RROW RESSURE GGE WIH NEEDLE VLVE -D03 -D05 -D03 -D05 O ( & LOCK) OR S5 ( D05 SULE) SHOWN-SEE MNIFOLD OIONS FILLER REHER SRE REURN OR 3/4" NF WIH DRO IE -D03 -D05 -D03 -D05 OIL LEVEL SIGH GGE 15.36 (390.1) NK DRIN SE-12 (LUGGED) 1.5 (38.1) 16.12 (409.5).12 (3.1) Motor Motor Description Dimension H-RM-Frame-hase U1.5-1725-56C-1 10.50 (266.70).75 (19.05) C1.75-1725-56C-1 11.00 (279.40).75 (19.05) 1 1-1725-56C-1 11.75 (298.45).75 (19.05) 3 1-1725-56C-3 10.50 (266.70).75 (19.05) F 1.5-1725-56C-3 10.75 (273.05).75 (19.05) G 2-1725-56C-3 11.75 (298.45).75 (19.05) K 3-1725-56C-3 12.62 (320.55).75 (19.05) L 5-1725-184C-3 14.38 (365.25) 1.13 (28.70) M 7.5-1725-213C-3 16.00 (406.40) 2.63 (66.80) N 10-1725-215C-3 16.28 (413.51) 2.63 (66.80) 20 M5* OION MNIFOLD (MULI-SION D05 MNIFOLD) SHOWN WIH OION O REURN FILER G arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Installation Information Vertical ower Units Volume Series H, Control V-aks Dimensions - asic H2, 3, 4 & V2, 3, 4 (20, 30, 40 Gallon ank) Millimeter equivalents for inch dimensions are shown in (**). Option Reference SRE REURN OR 3/4" NF WIH DRO IE 22.5 (571.5) 21.0 (533.4) 20.0 (508.0) OU 1.5 (38.1).56 DI. MOUNING HOLES - 4 LCES IN 20.0 (508.0) 17.0 (431.8) SRE REURN OR 3/4" NF WIH DRO IE ELECRIC MOOR UM REFILL OR FOR V-KS (8-15 GM ONLY) SYSEM RELIEF VLVE FOR H-KS SFEY RELIEF VLVE FOR V-KS O & S5 OION MNIFOLD ( & LOCK & D05 SINGLE SION) SHOWN WIH OION N REURN FILER.9 (22.9) O & S5 OION MNIFOLD ( & LOCK & D05 SINGLE SION) SIC UNI UM COMENSOR CONROL FOR V-KS (NO INCLUDED ON H-KS) ROION RROW RESSURE GGE WIH NEEDLE VLVE -D03 -D05 -D03 -D05 O ( & LOCK) OR S5 ( D05 SULE) SHOWN-SEE MNIFOLD OIONS FILLER REHER -D03 -D05 -D03 -D05 LIF EYES - 3 LCES SRE REURN OR 3/4" NF WIH DRO IE OIL LEVEL SIGH GGE OU C NK DRIN SE-12 (LUGGED) IN 1.5 (38.1) 19.5 (495.3) Motor Motor Description Dimension H-RM-Frame-hase.12 (3.1) U1.5-1725-56C-1 10.50 (266.70).75 (19.05) C1.75-1725-56C-1 11.00 (279.40).75 (19.05) 1 1-1725-56C-1 11.75 (298.45).75 (19.05) 3 1-1725-56C-3 10.50 (266.70).75 (19.05) F 1.5-1725-56C-3 10.75 (273.05).75 (19.05) G 2-1725-56C-3 11.75 (298.45).75 (19.05) K 3-1725-56C-3 12.62 (320.55).75 (19.05) L 5-1725-184C-3 14.38 (365.25) 1.13 (28.70) M 7.5-1725-213C-3 16.00 (406.40) 1.38 (35.05) N 10-1725-215C-3 16.28 (413.51) 1.38 (35.05) 15-1725-254C-3 17.63 (447.80) 3.35 (85.09) S 20-1725-256C-3 19.38 (492.25) 3.35 (85.09) Reservoir Reservoir Dimension Size C H2 or V2 H3 or V3 H4 or V4 20 Gallon 30 Gallon 40 Gallon 19.36 (491.74) 23.62 (599.95) 28.86 (733.04) M5* OION MNIFOLD (MULI-SION D05 MNIFOLD) SHOWN WIH OION N REURN FILER G 21 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU echnical Information Vertical ower Units Volume Series D, Control H, V-aks Manifold Options Millimeter equivalents for inch dimensions are shown in (**). SULY OR SE-10 REURN OR SE-10 SULY OR SE-10 REURN OR SE-10 REURN OR SE-10 D03 COVER LE OR SE-8 OR SE-8 3.44 (87.4) 2.06 (52.3) REURN OR SE-10 D03 MNG SURFCE OR SE-8 OR SE-8 1.25 (31.8) UM SULY 1.75 (44.2) UM SULY 3.38 (85.9) 1.88 (47.8).87 (22.0) 1.75 (44.5) O MNIFOLD OION FOR SULY & REURN CONNECIONS (5 GL. RESERVOIR UNIS) S3 SULE OION FOR USE WIH D1VW VLVE (NF D03) SULY OR SE-12 REURN OR SE-12 SULY OR SE-12 REURN OR SE-12 REURN OR SE-12 REURN OR SE-12 UM SULY D05 COVER LE OR SE-10 OR SE-10 1.75 (44.5) 2.12 (53.8) 1.75 (44.5) REURN OR SE-12 REURN OR SE-12 UM SULY D05 MNG SURFCE OR SE-10 OR SE-10 1.25 (31.8) 4.12 (104.6) -D03 -D05 -D03 -D05 1.50 (38.1) -D03 -D05 -D03 -D05.69 (17.5) 2.12 (53.8) O MNIFOLD OION FOR SULY & REURN CONNECIONS (10, 20, 30, 40 GL. RESERVOIR UNIS) S5 SULE OION FOR USE WIH D3W VLVE (NF D05) 22 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU echnical Information Vertical ower Units Volume Series D, Control H, V-aks Manifold Options Millimeter equivalents for inch dimensions are shown in (**). REURN OR SE-12 REURN OR SE-12 SULY OR SE-12 UM SULY REURN OR SE-12-4 Y Y -4 D05H(E) RNS LE OR SE-10 OR SE-10 1.25 (31.8) G SE-6 G UM SULY REURN OR SE-10 D03 MNG SURFCE & ORS SE-8 (U O 5 SIONS) 1.31 (33) - DO5HE Y - DO5H - DO5H Y - DO5HE 2.13 (54.1) ER SION -D03 -D05 -D03 -D05 1.50 (38.1) 4.25 (107.9) U O 5 SIONS G 2.12 (53.8).69 (17.5) 2.12 (53.8).88 (22.4) 1.75 (44.5) 1.06 (26.9) S6 SULE OION FOR USE WIH D31VW VLVE (NF D05H(E) WIH & Y ORS) M3* MULISION MNIFOLD OION FOR USE WIH D1VW VLVE (NF D03) REURN OR SE-12 REURN OR SE-16 G SE-6 G D05 MNG SURFCE & ORS SE-8 (U O 5 SIONS) 1.25 (31.8) G SE-6 G D05H MNG SURFCE & ORS SE-12 (U O 5 SIONS) 1.32 (33.5) UM SULY UM SULY 3.25 (82.6) ER SION 3.25 (82.5) ER SION 6.50 (165.1) U O 5 SIONS G 3.25 (82.6) 6.50 (165.1) U O 5 SIONS G 3.25 (82.5) 1.56 (39.6) 1.62 (41.1).69 (17.5) 2.12 (53.8).63 (16.0) 2.25 (57.2) M5* MULISION MNIFOLD OION FOR USE WIH D3W VLVES (NF D05) M6* MULISION MNIFOLD OION FOR USE WIH D31VW VLVES (NF D05H, NO & Y ORS) (20, 30, 40 GLLON UNIS) 23 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
UM COMENSOR CONROL Catalog HY13-1552-001/N,EU echnical Information Vertical ower Units Volume Series V-aks Control V-ak Compensator Options OMI OION SINGLE RESSURE REMOE COMENSOR OION SINGLE RESSURE REMOE COMENSOR W/LOW RESS. SNDY HIGH SI LOW SI LOW SOL SNDY SE -6 HIGH SOL SOLENOID IS 120 VC (LOW W) WIH DIN. 43650 CONNECOR ND MNUL OVERRIDE U. VEN OR (SE-6) UM COMENSOR CONROL DJUSMEN LOW RESS. SNDY (N.O.) ENERGIZE O UILD RESSURE UM COMENSOR CONROL DJUSMEN HI SOL LO SOL LO HI C OION I-RESSURE REMOE COMENSOR HIGH SI LOW SI D OION I-RESSURE REMOE COMENSOR W/LOW RESS. SNDY HIGH SI LOW SI LOW SOL SNDY HIGH SOL HIGH SOL SOLENOID IS 120 VC (LOW W) WIH DIN. 43650 CONNECOR ND MNUL OVERRIDE HIGH RESS. SOLENOID (N.O.) ENERGIZE FOR HIGH RESSURE UM COMENSOR HIGH RESS. CONROL SOLENOID IS 120 VC (LOW W) WIH DIN. 43650 CONNECOR ND MNUL OVERRIDE HIGH RESS. SOLENOID (N.O.) ENERGIZE FOR HIGH RESSURE LOW RESS. SNDY (N.O.) ENERGIZE FOR LOW RESSURE HI SOL LO SOL HI SOL LO SOL LO HI LO HI UM COMENSOR LOW RESS. CONROL UM COMENSOR HIGH RESSURE CONROL UM COMENSOR LOW RESSURE CONROL E OION ELECROHYDRULIC RESSURE CONROL INU RESSURE SIGNL M F OION ROVISION FOR CUSOMER SULIED REMOE COMENSOR SE -6 37 FLRE SE -6 UM COMENSOR RESSURE (INLE) OR DRIVER CRD CH OIN SOLENOID REQUIRES 24 VDC, 30 W OWER SULY (DIN 43650 CONNECOR) UM COMENSOR NK (REURN) OR SE-6 37 FLRE & ORS CH OINS FOR CUSOMER SULIED REMOE COMENSOR 24 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU echnical Information Vertical ower Units Volume Series D, Control H, V-aks ccessory Options D & H-KS Option Option C Option D Option E Option H Option J Option K Return Line ir/oil Heat (1 or 2) Return Line Water/Oil Heat Return Line Water/Oil Heat Water Line emperature Control Valve ressure Immersion Heater Check Valve ump Outlet W SEE MNIFOLD OIONS Option L Check Valve Return Line ypass Option M Return Line Option N Return Line Option O Return Line Option R Combination emp/level Switch (R1 or R2) Option V Return Line Option W ressure Switch (W1 or W2) Option Z emperature Switch SE-10 SE-6 H L MN O V SE-10 3/4" N SRE REURN M K C D E Z R J SE-12 V-KS Option Option Option C Option D Option E Option H Option J ump Case Heat Return Line ir/oil Heat (1 or 2) Return Line Water/Oil Heat Return Line Water/Oil Heat Water Line emperature Control Valve ressure Immersion Heater W SEE MNIFOLD OIONS Option K Check Valve ump Outlet Option L Check Valve Return Line ypass Option M Return Line Option N Return Line Option O Return Line Option R Combination emp/level Switch (R1 or R2) Option V Return Line Option W ressure Switch (W1 or W2) Option Z emperature Switch SE-10 SE-6 H L MN O V SE-10 K C D 3/4"N SRE REURN M SEE COMENSOR OIONS E Z R J SE-12 CONNEC O REURN LINE WIH OION 25 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU echnical Information Vertical ower Units Volume Series D-aks Control Dimensions - D-ak (5 Gallon ank) ccessories Millimeter equivalents for inch dimensions are shown in (**). SRE REURN OR 1/2" NF WIH DRO IE SRE REURN OR 1/2" NF WIH DRO IE (NO SHOWN) OU.78 (19.8) OION C WER/OIL HE ECHNGER (1" NF ORS) 3.0 (76.2) 4.4 (111.8) OION E WER EMERURE MODULING VLVE (3/4" NF ORS) 1.7 (43.2) 5.1 (129.5) REF. OION J IMMERSION HEER (1/2" ELEC. CONN.) IN OION W1 OR W2 RESSURE SWICH (DIN 43650 CONN.) OION M OR O REURN FILER OION 1 IR/OIL HE ECHNGER 2.6 (66.0) OION M OR O REURN FILER OION R1 OR R2 FLO/EM SWICH (1/2" ELEC. CONN.) DIM REF OION H RESSURE FILER FLO 1/2" ELOW LOW LEVEL 4.0 (101.6) 4.88 (124.0) 1.25 (31.8) 1.4 (35.6) 1.5 2.6 (38.1) (66.0) 5.8 (147.3) 26 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU echnical Information Vertical ower Units Volume Series H, Control V-aks Dimensions - H1 & V1 (10 Gallon ank) ccessories Millimeter equivalents for inch dimensions are shown in (**). 1.6 (40.6) SRE REURN OR 3/4" NF WIH DRO IE OION M, N, O OR V REURN FILER OION 1 IR/OIL HE ECHNGER 2.7 (68.6) SRE REURN OR 3/4" NF WIH DRO IE OION M, N, O OR V REURN FILER 2.0 (50.8) OU 6.4 (162.6) 3.2 (81.3) OION C WER/OIL HE ECHNGER (1" NF ORS) OION E WER EMERURE MODULING VLVE (3/4" NF ORS) 3.5 (88.9) IN 2.8 (71.1) OION UM CSE HE ECHNGER (USED ON V-KS ONLY) 4.2 3.53 (106.7) (89.6) 3.53 (89.6) DIM REF OION W1 OR W2 RESSURE SWICH (DIN 43650 CONN.) OION R1 OR R2 FLO/EM. SWICH (1/2" ELEC. CONN.) DIM REF OION H RESSURE FILER -D03 -D05 -D03 -D05 2.2 (55.8) -D03 -D05 -D03 -D05 OION J IMMERSION HEER (3/4" ELEC CONN.) OION Z EMERURE SWICH (1/2" ELEC. CONN.) 6.4 (162.6) 3.6 (91.4) FLO 2" ELOW LOW LEVEL 6.0 (152.4) 1.5 (38.1) 1.4 (35.6) 2.6 (66.0) 7.7 (195.6) 1.4 (35.6) 1.5 (38.1) 6.8 (172.7) 27 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU echnical Information Vertical ower Units Volume Series H, Control V-aks Dimensions - H2, 3, 4 & V2, 3, 4 (20, 30, 40 Gallon ank) ccessories Millimeter equivalents for inch dimensions are shown in (**). 4.1 (104.1) 2.1 (53.3).75 (19.1) OION M, N, O OR V REURN FILER SRE REURN OR 3/4" NF WIH DRO IE OU IN SRE REURN OR 3/4" NF WIH DRO IE OION 2 IR/OIL HE ECHNGER 5.0 6.6 (127.0) (167.6) 6.5 (165.1) 3.2 (81.3) OION M, N, O OR V REURN FILER OION D WER/OIL HE ECHNGER (3/4" NF ORS) OION E WER EMERURE MODULING VLVE (3/4" NF ORS) OU IN 2.3 (58.4) 5.1 (129.5) 4.9 (124.5) 3.53 (89.7) OION IR/OIL HE ECHNGER (USED ON V-CKS ONLY) DIM REF OION W1 OR W2 RESSURE SWICH (DIN 43650 CONN.) OION R1 OR R2 FLO/EM. SWICH (1/2" ELEC. CONN.) DIM REF -D03 -D05 -D03 -D05 -D03 -D05 -D03 -D05 OION H RESSURE FILER OION J IMMERSION HEER 3/4" ELEC. CONN.) 6.0 (152.4) 2.2 (55.9) OION Z EMERURE SWICH (1/2" ELEC.CONN.) 7.6 (193.0) 6.7 (170.2) FLO 2" ELOW LOW LEVEL 7.50 (190.5) 1.5 (38.1) 1.5 (38.1) 4.62 (117.4) 9.5 (241.3) 1.4 (35.6) 1.50 (38.1) 28 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU echnical Information Vertical ower Units Volume Series D, Control H, V-aks erformance Data Maximum Working ressures **** Represents maximum operating pressure with pump/motor combination. his will be the maximum relief valve or compensator setting. **** Represents maximum operating pressure with pump/motor combination. When used on power unit products this will represent a 3000 SI relief valve or compensator setting. D & H-ak - ump/motor Combinations Maximum Operating ressure ump Motor Horsepower Flow at.5.75 1 1.5 2 3 5 7.5 10 15 20 1725 RM Max Operating ressure (heoretical) 0.9 810 1220 1620 2430 3240 1.3 580 870 1160 1730 2310 3470 1.8 430 640 860 1280 1720 2570 4280 2.3 330 500 670 1000 1340 2010 3350 2.7 290 440 580 870 1170 1750 2920 4370 3.2 230 350 460 700 930 1400 2330 3500 4.5 160 250 330 490 660 1000 1670 2500 3320 5.1 150 220 300 440 590 890 1480 2220 2960 4430 6.3 120 180 240 360 480 720 1200 1800 2400 3600 8.1 90 140 180 270 360 540 910 1360 1820 2720 3640 9.4 80 120 160 240 310 470 780 1180 1570 2350 3130 12.3 60 90 120 170 230 350 580 870 1160 1740 2320 V-ak - ump/motor Combinations Maximum Operating ressure Motor Horsepower ump GM @ 1725 RM 2 3 5 7.5 10 15 20 V16 2.0 1050 1570 2600 3860 V16 2.5 930 1370 2250 3370 V16 3.0 830 1230 2000 3000 V16 3.5 750 1100 1800 2680 3570 V16 4.0 680 1000 1650 2440 3240 V16 4.5 630 920 1500 2230 2970 4430 V16 5.0 580 850 1400 2060 2740 4080 V16 5.5 550 800 1300 1920 2540 3790 V16 6.0 510 750 1210 1790 2370 3540 V16 6.5 480 700 1130 1680 2220 3310 V16 7.0 450 660 1070 1580 2100 3120 V33 8.0 600 960 1420 1880 2800 3700 V33 8.5 570 930 1350 1790 2650 3520 V33 9.0 540 880 1290 1700 2530 3350 V33 9.5 520 840 1230 1630 2410 3200 V33 10.0 500 800 1180 1550 2310 3000 V33 10.5 480 770 1130 1490 2210 2940 V33 11.0 460 740 1090 1430 2130 2820 V33 11.5 450 710 1050 1380 2050 2710 V33 12.0 430 690 1010 1330 1970 2610 V33 12.5 420 670 970 1280 1900 2520 V33 13.0 410 650 940 1240 1840 2430 V33 13.5 390 630 910 1200 1780 2350 V33 14.0 380 610 880 1160 1720 2280 V33 14.5 370 590 860 1130 1670 2210 V33 15.0 360 570 830 1090 1620 2140 29 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU echnical Information Vertical ower Units Volume Series D, Control H, V-aks erformance Data umps V16 @ 1800 RM Volumetric Efficiency 20 20 Standard umps 100 30 50 V33 @ 1800 RM Volumetric Efficiency 100 16 16 Overall Efficiency 80 24 40 Overall Efficiency 80 Delivery GM 12 8 0 Horsepower H 12 8 4 4 Outlet Flow 0 0 0 1000 2000 3000 ressure - SI Input Horsepower at Full Flow Compensated Horsepower 60 40 20 Efficiency - % Delivery GM 18 12 0 Horsepower H 30 20 6 10 Outlet Flow Input Horsepower at Full Flow Compensated Horsepower 0 0 0 1000 2000 3000 ressure - SI 60 40 20 Efficiency - % NOE: he efficiencies and data in the graph are good only for pumps running at 1800 RM and stroked to maximum. o calculate approximate horsepower for the other conditions, use the following formula: [ ] H = Q x (SI) N + (CHp) x 1714 1800 ctual GM is directly proportional to drive speed and maximum volume setting. Flow loss, however, is a function of pressure only. WHERE: Q = ctual Output Flow in GM SI = ressure t ump Outlet CHp = Input Horsepower @ Full compensation @ 1800 RM (from graph read at operating pressure) N = Drive Speed in RM Horsepower Limited umps 8 V16 @ 1800 RM 20 V33 @ 1800 RM Outlet Flow (GM) 6 4 2 0 C D E C 0 1000 2000 3000 ressure - SI F D E F 12 10 8 6 4 2 0 Horsepower H 500 400 300 200 100 0 Input orque (In.-Lb.) Outlet Flow (GM) 15 10 5 0 C D E 0 1000 2000 3000 ressure - SI D E C 30 25 20 15 10 5 0 Horsepower H 1000 800 600 400 200 0 Input orque (In.-Lb.) V16 FULL SROKE MOOR H 2 3 5 7.5 10 15 Compensator Setting (SI) 1400 1950 2500 3000 3000 3000 V33 FULL SROKE MOOR H 5 7.5 10 15 20 Compensator Setting (SI) 1900 2400 2900 3000 3000 ump Control Option H with V16 Horsepower Limiting Factory Compensator Settings ump Control Option H with V33 Horsepower Limiting Factory Compensator Settings 30 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU echnical Information Vertical ower Units Volume Series D, Control H, V-aks erformance Data Heat s 2 ir/oil Heat s, 1 & 2 used with 1800 RM EFC Motors Horsepower Removed y Cooler 1.5 1.8.6.5.4.3 1* 1 2 0 - ump Case H. E. with 56C-256C Motors 1* - Return Line H. E. (D5 ower Units Only) 1 - Return Line H. E. with 56C-184C Motors 2 - Return Line H. E. with 213C-256C Motors.3 Heat removal is based on 40 F differential between transfer medium..4.5.6.8 1 1.5 2 3 4 5 6 8 10 15 20 25 Oil Flow - GM Oil ressure Drop at 100 SSU = 5 SI = 10 SI = 20 SI 10 Water/Oil Heat s C (1:1 Oil/Water Ratio) D (2:1 Oil/Water Ratio) 8 7 Horsepower Removed y Cooler 6 5 4 3 2 C D 1.5 C - Return Line H. E. (9 GM Max.) D - Return Line H. E. (4.5 GM Min.) Heat removal is based on 40 F differential between transfer medium, using 85 F cooling water. he Oil/Water ratio of 2:1 means that for every 2 gallons of oil through the cooler, a minimum of 1 gallon of 85 F water must be circulated to achieve curve results. 1.5 2 3 4 5 6 8 10 15 20 25 30 Oil Flow - GM Oil ressure Drop at 100 SSU = 5 SI = 10 SI Horsepower Removed y Reservoir H REMOVL RESERVOIR SIZE (GLLONS) 5 10 20 30 40 0.2 0.38 0.58 0.68 0.81 Heat removal is based on static ambient air at 85 F and max. oil temperature of 135 F. 31 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Information Vertical ower Units Volume Series D-aks Control D-aks Omit If Not Required W Omit If Not Required Reservoir ressure ump No Motor Electric Manifold Control Flow (See Note) Motor ** Reservoir Size (Gallons) D5 5 Omit ressure Control Description System ressure Relief Valve Only System ressure Relief Valve with Unloading Valve (2-Way 120VC) N.O. (Energize coil to close) Note: wo and three pressure control options with unloading valve available, consult factory. Motor Description (H-RM-Frame-hase) U1.5-1725 - 145CZ - 1 C1.75-1725 - 145CZ - 1 1 1-1725 - 145CZ - 1 3 1-1725 - 145CZ - 3 F 1.5-1725 - 145CZ - 3 G 2-1725 - 145CZ - 3 K 3-1725 - 145CZ - 3 Single phase electric motors are rated as follows: 115/230V, 1H, EFC - 60 Hertz 1800 RM hree phase electric motors are rated as follows: 200-230/460V, 3H, EFC - 60 Hertz 1800 RM 190-220/380-440V, 3H, EFC - 50 Hertz 1500 RM Consult factory for other motor speeds (RM) and voltages. ** Use W prefix when no motor is required on unit. When ordering, W must be followed by motor model code equivalent. Motor coupling will have interface for a 56C frame motor. ump Used 0.9 G5050020 Comments 1.3 G5050020 vailable With.5H 1.8 G5050040 hru 3 H Motors Only 2.3 G5050050 2.7 G5050060 orting lock/subplate Supply/Return ort or Manifold ype or ctuator ort Size O Other ressure and Return ort lock & orts Convertible to with Safety Relief Valve SE-10 Str. hr d S3 Option S3 M3 * D03 Single Station Subplate & orts Spare & with Safety Relief Valve SE-8 Str. hr d SE-10 orts D03 Multistation arallel Circuit Manifold & orts Spare G ort with Safety Relief Valve SE-8 Str. hr d SE-6 * When ordering Multi-Station Manifolds, the number of stations must be specified. If more than 5 stations required, consult factory. If valves are to be mounted, specify the valves and sequence. If the model code exceeds 25 digits, utilize the special ordering code. Example: D5 1. 2 1 M33 NOE: = 3 Station Manifold Manifolds are mounted vertically. Station #1: ottom station is number 1. Station #2: Station #3: C4 32 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Information Vertical ower Units Volume Series D-aks Control D-aks Omit If Not Omit If Not Omit If Not Omit If Not Not Required Required Required Required Required When Directional Manapak ccessories Special Modifications Design Series Control Valve Control Valves Indicates Special Modification Has een Specified 1 3 5 7 Valve NF Nominal Function Model Mounting Flow Number ad (GM) Flow Control ilot Operator Check ort Check ort ressure RM225KN Reducing (150-3000) FM2DDKN D03 7 COM2DDN D03 7 CM2N D03 7 D03 6 Valve NF Nominal Solenoid Model Mounting Flow Operator Number ad (GM) -110 VC D1VW20NYCF D03 7 D1VW1CNYCF D03 7 C D1VW4CNYCF D03 7 D D1VW20DNYCF D03 7 S D1VW2CNYCF D03 7 D1VW8CNYCF D03 7 Single (Spr. Ret) (Detent) (Spr. Ctr.) (Spr. Ctr.) Circuit Symbol Circuit Symbol Function Model echnical Number Data 1* ir/oil:.7h Return Heat RM-08-2-2 Rejection @ 3 GM (5 SI Diff. @ 3 GM) Oil/Water (1:1): 3H C* Return Heat Rej. @ 3 GM N40140 (9 GM Max.) (5 SI Diff. @ 3 GM) Water emp. 75 F to 135 F dj. Range E Modulating V47C-6 Cross mbient Sensing Valve 3/4" N Inlet H J K L M ressure Immersion Heater Check Valve ump Outlet ypass Check (On Heat Exch.) Return 15110RS E2-251-L D370MOMF05 C1020S65 Microglass Element Vis. Ind. - 50 SI ypass (2 SI Diff. @ 3 GM) 250 Watt, 120 V, 1H, 120 F Fixed hermostat NEM 4 (2.1 mps) 5 SI Cracking ressure (7 SI Diff. @ 3 GM) 65 SI Cracking ressure 15CN110 Microglass Element (3 SI Diff. Visual 25 SI Indicator @ 3 GM) O 1210C Cellulose Element Return (12 GM Ind. Gage - 15 SI ypass Max. Oil Flow) Combination Fixed emp at 149 F R1 Float/emp. SW 876782-01 Close @ Low Level N.O. Float Up nd/or 149 F (N.O.) Combination Fixed emp at 150 F R2 Float/emp. SW 876782-02 Open @ Low Level N.O. Float Up nd/or 150 F (N.C.) W1 W2 ressure Switch 90-700 SI ressure Switch 700-3000 SI N.O. & N.C. Contacts 876731-01 (SD Switch) DIN 43650 Connector 5 @ 125/250VC Induct 876731-02 7 @ 12/25VDC Induct * Heat rejection based on flow given with a 40 F differential between transfer medium. Units less valves will be supplied with station cover plates installed. 33 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Information Vertical ower Units Volume Series H-aks Control H-aks Omit If Not Required W Omit If Not Required Reservoir ressure ump No Motor Electric Manifold Control Flow (See Note) Motor ** Reservoir Size (Gallons) H1* 10 H2 20 H3 30 H4 40 * vailable up to 10H motor only. Omit ressure Control Description System ressure Relief Valve Only System ressure Relief Valve with Unloading Valve (2-Way 120VC) N.O. (Energize coil to close) Note: wo and three pressure control options with unloading valve available, consult factory. ump Used 0.9 G5050020 1.3 G5050030 1.8 G5050040 2.3 G5050050 2.7 G5050060 3.2 G5110070 4.5 G5110100 5.1 G5110110 6.3 G5110140 8.1 G5110180 9.4 G5110210 12.3 G5110280 vailable with H2, H3, H4 anks Only Motor Description (H-RM-Frame-hase) U1.5-1725 - 56C - 1 C1.75-1725 - 56C - 1 1 1-1725 - 56C - 1 3 1-1725 - 56C - 3 F 1.5-1725 - 56C - 3 G 2-1725 - 56C - 3 K 3-1725 - 56C - 3 L 5-1725 - 184C - 3 M 7.5-1725 - 213C - 3 N 10-1725 - 215C - 3 15-1725 - 254C - 3 S 20-1725 - 256C - 3 Single phase electric motors are rated as follows: 115/230V, 1H, EFC-60 Hertz 1800 RM. hree phase electric motors are rated as follows: 208-230/460V, 3H, EFC-60 Hertz 1800 RM. Consult factory for other motor speeds (RM) and voltages. ** Use W prefix when no motor is required on unit. When ordering, W must be followed by motor model code equivalent to frame size of motor to be used. vailable with H2, H3, H4 anks Only. orting lock/subplate Supply/Return ort or Manifold ype ctuator ort Size Other O ressure and Return ort lock & orts Convertible to with Safety Relief Valve SE-12 Str. hr d S3, S5, S6 Option S3 D03 Single Station Subplate & orts Spare & with Safety Relief Valve SE-8 Str. hr d SE-10 orts S5 D05 Single Station Subplate & orts Spare & with Safety Relief Valve SE-10 Str. hr d SE-12 orts S6 D05H/D05HE Single Station Subplate & orts & Y orts with Safety Relief Valve SE-10 Str. hr d SE-4 (H & HE) M3 * D03 Multistation arallel Circuit Manifold & orts Spare G ort with Safety Relief Valve SE-8 Str. hr d SE-6 M5 * D05 Multistation arallel Circuit Manifold & orts Spare G ort with Safety Relief Valve SE-8 Str. hr d SE-6 M6 * D05H Multistation arallel Circuit Manifold & orts Spare G SE-6 with Safety Relief Valve SE-12 Str. hr d No & Y orts * When ordering Multi-Station Manifolds, the number of stations must be specified. If more than 5 stations required, consult factory. If valves are to be mounted, specify the valves and sequence. If the model code exceeds 25 digits, utilize the special ordering code. Example: H2 6.3 N M53 NOE: = 3 Station Manifold Manifolds are mounted vertically. Station #1: E ottom station is number 1. Station #2: F Station #3: G4 vailable with H2, H3, H4 only. 34 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Information Vertical ower Units Volume Series H-aks Control H-aks Omit If Not Omit If Not Omit If Not Omit If Not Not Required Required Required Required Required When Directional Manapak ccessories Special Modifications Design Series Control Valve Control Valves Indicates Special Modification Has een Specified 1 2 3 4 5 6 7 8 Valve NF Nominal Function Model Mounting Flow Number ad (GM) Flow Control Flow Control ilot Operator Check ilot Operator Check ort Check ort Check ort ressure RM225KN Reducing (150-3000) Valve NF Nominal Solenoid Model Mounting Flow Operator Number ad (GM) -110 VC D1VW20NYCF D03 7 D1VW1CNYCF D03 7 C D1VW4CNYCF D03 7 D D1VW20DNYCF D03 7 E D3W1NYCF D05 12 F D3W1CNYCF D05 12 G D3W4CNYCF D05 12 H D3W1DNYCF D05 12 J D31VW204NYCF D05H 20 K D31VW1C4NYCF D05H 20 L D31VW4C4NYCF D05H 20 M D31VW20D4NYCF D05H 20 S D1VW2CNYCF D03 7 D1VW8CNYCF D03 7 V D3W2CNYCF D05 12 W D3W8CNYCF D05 12 FM2DDKN D03 7 FM3DDKN D05 12 COM2DDN D03 7 COM3DDN D05 12 CM2N D03 7 CM3N D05 12 D03 6 ort ressure RM325KN D05 12 Reducing Units less valves will be supplied with station cover plates installed. Single (Spr. Ret) (Detent) Single (Spr. Ret) (Detent) Single (Spr. Ret) (Detent) Circuit Symbol Circuit Symbol Function Model echnical Number Data 1* Return Heat RM-08-1-2 ir/oil:.7h Rejection @ 7 GM ( 1 /2-5H Motors Only) 2* ir/oil: 1.5H Return Heat RM-190-1-2 Rejection @ 7 GM (7.5-15H Motors Only) Oil/Water (1:1): 5H C* Return Heat Rej. @ 7 GM N40140 (9 GM Max.) (9 SI Diff. @ 7 GM) Oil/Water (2:1): 4H D* Return Heat Rej. @ 7 GM N7016F (25 GM Max.) (3 SI Diff. @ 7 GM) Water emp. 75 F to 135 F dj. Range E Modulating V47C-6 Cross mbient Sensing Valve 3/4" N Inlet H J K L M N ressure Immersion Heater Check Valve ump Outlet ypass Check (On Heat Exch.) Return Return 15110RS GS79J6-W1 D & C Series C1220S65 15CN110 40CN110 Microglass Element Vis. Ind. - 50 SI ypass (4 SI Diff. @ 7 GM) 1 KW, 120/240 V, 1H, 30-110 F hermostat NEM 4 (23 W/Sq.In.) 5 SI Cracking ressure (25 SI Diff. @ 15 GM) 65 SI Cracking ressure Microglass Element Visual 25 SI Indicator (5 SI Diff. @ 7 GM) Microglass Element Visual 25 SI Indicator (3 SI Diff. @ 7 GM) O 1210C Cellulose Element Return (12 GM Max. Ind. Gage - 15 SI ypass Oil Flow) Combination Fixed emp at 149 F R1 Float/emp. SW 876782-01 Close @ Low Level N.O. Float Up nd/or 149 F (N.O.) Combination Fixed emp at 150 F R2 Float/emp. SW 876782-02 Open @ Low Level N.O. Float Up nd/or 150 F (N.C.) V W1 W2 Z Return ressure Switch 90-700 SI ressure Switch 700-3000 SI emperature 837-4 Switch NEM 1 5010C Cellulose Element (35 GM Max. Ind. Gage - 15 SI ypass Oil Flow) N.O. & N.C. Contacts 876731-01 (SD Switch) DIN 43650 Connector 5 @ 125/250VC Induct 876731-02 7 @ 12/25VDC Induct 60 F-190 F djust. Differential N.O. & N.C. Contacts * Heat rejection based on flow given with a 40 F differential between transfer medium. 35 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Information Vertical ower Units Volume Series V-aks Control V-aks 2 thru 7 GM Omit If Not Omit If Not Omit If Not Required Required Required 7 OR Reduced W Flow Reservoir Remote ump ump No Motor Electric Manifold Compensator Control Flow (See Note) Motor Options ** Omit C D E* F Reservoir Size (Gallons) V1* 10 V2 20 V3 30 V4 40 * vailable up to 10H motor. Compensator Description Single ressure Remote Compensator Single ressure Remote Compensator With Low ressure Standby I-ressure Remote Compensator I-ressure Remote Compensator With Low ressure Standby Electrohydraulic ressure Control rovision For Customer Supplied Remote Control Relief Valve * Consult factory for driver card options. Omit * H** ump Control Option Std. Remote Compensator Load Sense (Flow Control) Horsepower Limiting NOE: For shaded options & H, lead time is four weeks. * Unless otherwise specified, a SE-6 sense port line will be supplied in topplate. When shuttle check option (9 or 0) is specified on D03 or D05 manifold, sense line will be plumbed to shuttle check. **Unless otherwise specified, horsepower setting will be at max. flow & pressure obtainable with motor selected. Reference ump H curves on page 18. O S3 S5 S6 M3 * M5 * M6 * G K L M N Motor Description (H-RM-Frame) 2-1725 - 56C 3-1725 - 56C 5-1725 - 184C 7.5-1725 - 213C 10-1725 - 215C 15-1725 - 254C S 20-1725 - 256C Electric motors are 208-230/460V, 60Hz, 3H 1800 RM. EFC consult factory for other motor speeds (RM) and voltages. ** Use W prefix when no motor is required on unit. When ordering, W must be followed by motor model code equivalent to frame size of motor to be used. ump Flow Rate ump Used and Description @ 1800 RM 7 7.8 V16 - Std. Remote Compensator * Specify in GM Destroked Max. Volume (2 GM Min.) * Unless otherwise specified, units are shipped at max. flow rate (7.8 GM) at 1800 RM. When reduced flow setting is required, specify pump setting in.5 GM increments. Example: 5, 5.5, 6, 6.5 with a 2 GM minimum flow. If horsepower limiting pump (H) control is required to be destroked, utilize the special ordering code. Example: V*5**-- = Std. ump Destroked to 5 GM V*4.5**-- = Load Sense ump Destroked to 4.5 GM ump Control/Mounting Supply/Return ort ctuator ort Size Other ressure and Return ort lock & ort Convertible to with Safety Relief Valve SE-12 Str. hr d S3, S5, S6 Option D03 Single Station Subplate & orts Spare & with Safety Relief Valve SE-8 Str. hr d SE-10 orts D05 Single Station Subplate & orts Spare & with Safety Relief Valve SE-10 Str. hr d SE-12 orts D05H/D05HE Single Station Subplate & orts & Y orts with Safety Relief Valve SE-10 Str. hr d SE-4 (H & HE) D03 Multistation arallel Circuit Manifold & orts Spare G ort with Safety Relief Valve SE-8 Str. hr d SE-6 D05 Multistation arallel Circuit Manifold & orts Spare G ort with Safety Relief Valve SE-8 Str. hr d SE-6 D05H Multistation arallel Circuit Manifold & orts Spare G SE-6 with Safety Relief Valve SE-12 Str. hr d No & Y orts * When ordering Multi-Station Manifolds, the number of stations must be specified. If more than 5 stations required, consult factory. If valves are to be mounted, specify the valves and sequence. If the model code exceeds 25 digits, utilize the special ordering code. Example: V2 7 N M33 NOE: = 3 Station Manifold Manifolds are mounted vertically. Station #1: ottom station is number 1. Station #2: Station #3: C24 vailable with V2, V3, V4 only. 36 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Information Vertical ower Units Volume Series V-aks Control V-aks 2 thru 7 GM Omit If Not Omit If Not Omit If Not Omit If Not Not Required Required Required Required Required When Directional Manapak ccessories Special Modifications Design Series Control Valve Control Valves Indicates Special Modification Has een Specified 1 2 3 4 5 6 7 8 9* Valve NF Nominal Function Model Mounting Flow Number ad (GM) Flow Control Flow Control ilot Operator Check ilot Operator Check ort Check ort Check ort ressure Reducing ort ressure Reducing Shuttle Check (Load Sense) FM2DDKN D03 7 FM3DDKN D05 12 COM2DDN D03 7 COM3DDN D05 12 CM2N D03 7 CM3N D05 12 RM2-25KN RM3-25KN D03 6 D05 12 D03 Circuit Symbol Shuttle Check 0* D05 (Load Sense) * Use in combination with load sense pump type (7) and flow control valve option (1 or 3). Valve NF Nominal Solenoid Model Mounting Flow Operator Number ad (GM) -110 VC D1VW20NYCF D03 7 D1VW1CNYCF D03 7 C D1VW4CNYCF D03 7 D D1VW20DNYCF D03 7 E D3W1NYCF D05 12 F D3W1CNYCF D05 12 G D3W4CNYCF D05 12 H D3W1DNYCF D05 12 Units less valves will be supplied with station cover plates installed. Single (Spr. Ret) (Detent) Single (Spr. Ret) (Detent) Circuit Symbol LS LS Function Model echnical Number Data ump Case ir/oil:.7h * Heat RM-08-4-2 Rejection @.5 GM (2-15H Motors) 1* ir/oil:.7h Return Heat RM-08-1-2 Rejection @ 7 GM (2-5H Motors Only) 2* ir/oil: 1.5H Return Heat RM-190-1-2 Rejection @ 7 GM (7.5-15H Motors Only) Oil/Water (1:1): 5H C* Return Heat Rej. @ 7 GM N40140 (9 GM Max.) (9 SI Diff. @ 7 GM) Oil/Water (2:1): 4H D* Return Heat Rej. @ 7 GM N7016F (25 GM Max.) (3 SI Diff. @ 7 GM) Water emp. 75 F to 135 F dj. Range E Modulating V47C-6 Cross mbient Sensing Valve 3/4" N Inlet H J K L M N ressure Immersion Heater Check Valve ump Outlet ypass Check (On Heat Exch.) Return Return 15110RS GS79J6-W1 D750MOMF05 C1220S65 15CN110 40CN110 Microglass Element Vis. Ind. - 50 SI ypass (4 SI Diff. @ 7 GM) 1 KW, 120/240 V, 1H, 30-110 F hermostat NEM 4 (23 W/Sq.In.) 5 SI Cracking ressure (8 SI Diff. @ 7 GM) 65 SI Cracking ressure Microglass Element Visual 25 SI Indicator (5 SI Diff. @ 7 GM) Microglass Element Visual 25 SI Indicator (3 SI Diff. @ 7 GM) O 1210C Cellulose Element Return (12 GM Max. Ind. Gage - 15 SI ypass Oil Flow) Combination Fixed emp at 149 F R1 Float/emp. SW 876782-01 Close @ Low Level N.O. Float Up nd/or 149 F (N.O.) Combination Fixed emp at 150 F R2 Float/emp. SW 876782-02 Open @ Low Level N.O. Float Up nd/or 150 F (N.C.) V W1 W2 Z Return ressure Switch 90-700 SI ressure Switch 700-3000 SI emperature 837-4 Switch NEM 1 5010C Cellulose Element (35 GM Max. Ind. Gage - 15 SI ypass Oil Flow) N.O. & N.C. Contacts 876731-01 (SD Switch) DIN 43650 Connector 5 @ 125/250VC Induct 876731-02 7 @ 12/25VDC Induct 60 F-190 F djust. Differential N.O. & N.C. Contacts * Heat rejection based on flow given with a 40 F differential between transfer medium. 37 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Information Vertical ower Units Volume Series V-aks Control V-aks 8 thru 15 GM Omit If Not Omit If Not Omit If Not Required Required Required 15 OR Reduced W Flow Reservoir Remote ump ump No Motor Electric Manifold Compensator Control Flow (See Note) Motor Options ** Omit C D E* F Reservoir Size (Gallons) V2 20 V3 30 V4 40 Compensator Description Single ressure Remote Compensator Single ressure Remote Compensator With Low ressure Standby i-ressure Remote Compensator i-ressure Remote Compensator With Low ressure Standby Electrohydraulic ressure Control rovision For Customer Supplied Remote Control Relief Valve * Consult factory for driver card options. Omit * H** ump Control Option Std. Remote Compensator Load Sense (Flow Control) Horsepower Limiting NOE: For shaded options & H, lead time is four weeks. * Unless otherwise specified, a SE-6 sense port line will be supplied in topplate. When shuttle check option (9 or 0) is specified on D03 or D05 manifold, sense line will be plumbed to shuttle check. ** Unless otherwise specified, horsepower setting will be at max. flow & pressure obtainable with motor selected. Reference ump H curves on page 18. L M N Motor Description (H-RM-Frame) 5-1725 - 184C 7.5-1725 - 213C 10-1725 - 215C 15-1725 - 254C S 20-1725 - 256C Electric motors are 208-230/460V, 60Hz, 3H 1800 RM. EFC consult factory for other motor speeds (RM) and voltages. ** Use W prefix when no motor is required on unit. When ordering, W must be followed by motor model code equivalent to frame size of motor to be used. orting lock/subplate Supply/Return ort or Manifold ype or ctuator ort Size O S3 S5 ump Flow Rate @ 1800 RM ump Used and Description 15 15.6 V33 - Std. Remote Compensator * Specify in GM Destroked Max. Volume (8 GM Min.) * Unless otherwise specified, units are shipped at max. flow rate (15.6 GM) at 1800 RM. When reduced flow setting is required, specify pump setting in.5 GM increments. Example: 11, 11.5, 12, 12.5 with a 8 GM minimum flow. If horsepower limiting pump (H) control is required to be destroked, utilize the special ordering code. Example: V*12**-- = Std. ump Destroked to 12 GM V*11.5**-- = Load Sense ump Destroked to 11.5 GM Other ressure and Return ort lock & orts Convertible to with Safety Relief Valve SE-12 Str. hr d S3, S5, S6 Option D03 Single Station Subplate & orts Spare & with Safety Relief Valve SE-8 Str. hr d SE-10 orts D05 Single Station Subplate & orts Spare & with Safety Relief Valve SE-10 Str. hr d SE-12 orts S6 M3 * M5 * M6 * D05H/D05HE Single Station Subplate & orts & Y orts with Safety Relief Valve SE-10 Str. hr d SE-4 (H & HE) D03 Multistation arallel Circuit Manifold & orts Spare G ort with Safety Relief Valve SE-8 Str. hr d SE-6 D05 Multistation arallel Circuit Manifold & orts Spare G ort with Safety Relief Valve SE-8 Str. hr d SE-6 D05H Multistation arallel Circuit Manifold & orts Spare G SE-6 with Safety Relief Valve SE-12 Str. hr d No & Y orts * When ordering Multi-Station Manifolds, the number of stations must be specified. If more than 5 stations required, consult factory. If valves are to be mounted, specify the valves and sequence. If the model code exceeds 25 digits, utilize the special ordering code. Example: V3 11 N M53 NOE: = 3 Station Manifold Manifolds are mounted vertically. Station #1: E ottom station is number 1. Station #2: F Station #3: G4 38 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Information Vertical ower Units Volume Series V-aks Control V-aks 8 thru 15 GM Omit If Not Omit If Not Omit If Not Omit If Not Not Required Required Required Required Required When Directional Manapak ccessories Special Modifications Design Series Control Valve Control Valves Indicates Special Modification Has een Specified 1 2 3 4 5 6 7 8 9* Valve NF Nominal Function Model Mounting Flow Number ad (GM) Flow Control Flow Control ilot Operator Check ilot Operator Check ort Check ort Check ort ressure RM225KN Reducing (150-3500) ort ressure Reducing Shuttle Check (Load Sense) FM2DDKN D03 7 FM3DDKN D05 12 COM2DDN D03 7 COM3DDN D05 12 CM2N D03 7 CM3N D05 12 RM3-25KN D03 6 D05 12 D03 Circuit Symbol Shuttle Check 0* D05 LS (Load Sense) * Use in combination with load sense pump type (15) and flow control valve option (1 or 3). Valve NF Nominal Solenoid Model Mounting Flow Operator Number ad (GM) -110 VC D1VW20NYCF D03 7 D1VW1CNYCF D03 7 C D1VW4CNYCF D03 7 D D1VW20DNYCF D03 7 E D3W1NYCF D05 12 F D3W1CNYCF D05 12 G D3W4CNYCF D05 12 H D3W1DNYCF D05 12 J D31VW204NYCF D05H 20 K D31VW1C4NYCF D05H 20 L D31VW4C4NYCF D05H 20 M D31VW20D4NYCF D05H 20 Single (Spr. Ret) (Detent) Single (Spr. Ret) (Detent) Single (Spr. Ret) (Detent) Units less valves will be supplied with station cover plates installed. Circuit Symbol LS Function Model echnical Number Data ump Case ir/oil:.7h * Heat RM-08-4-2 Rejection @.5 GM (2-20H Motors) 1* Return Heat RM-08-1-2 ir/oil:.7h Rejection @ 15 GM (2-5H Motors Only) 2* ir/oil: 1.7H Return Heat RM-190-1-2 Rejection @ 15 GM (7.5-20H Motors Only) Oil/Water (2:1): 6.5H D* Return Heat Rej. @ 15 GM N7016F (25 GM Max.) (3 SI Diff. @ 15 GM) Water emp. 75 F to 135 F dj. Range E Modulating V47C-6 Cross mbient Sensing Valve 3/4" N Inlet H J K L M N ressure Immersion Heater Check Valve ump Outlet ypass Check (on Heat Exch.) Return Return 15110RS GS79J6-W1 Microglass Element Vis. Ind. - 50 SI ypass (12 SI Diff. @ 15 GM) 1 KW, 120/240 V, 1H, 30-110 F hermostat NEM 4 (23 W/Sq.In.) 5 SI D750MOMF05 Cracking ressure (25 SI Diff. @ 15 GM) C1220S65 15CN110 40CN110 65 SI Cracking ressure Microglass Element Visual 25 SI Indicator (9 SI Diff. @ 15 GM) Microglass Element Visual 25 SI Indicator (5 SI Diff. @ 15 GM) O 1210C Cellulose Element Return (12 GM Ind. Gage - 15 SI ypass Max. Oil Flow) Combination Fixed emp at 149 F R1 Float/emp. SW 876782-01 Close @ Low Level N.O. Float Up nd/or 149 F (N.O.) Combination Fixed emp at 150 F R2 Float/emp. SW 876782-02 Open @ Low Level N.C. Float Up nd/or 150 F (N.C.) V W1 W2 Z Return ressure Switch 90-700 SI ressure Switch 700-3000 SI emperature 837-4 Switch NEM 1 5010C Cellulose Element (35 GM Ind. Gage - 15 SI ypass Max. Oil Flow) N.O. & N.C. Contacts 876731-01 (SD Switch) DIN 43650 Connector 5 @ 125/250VC Induct 876731-02 7 @ 12/25VDC Induct 60 F-190 F djust. Differential N.O. & N.C. Contacts * Heat rejection based on flow given with a 40 F differential between transfer medium. 39 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU Installation Information Vertical ower Units Volume Series D, Control H, V-aks Operating Notes Jog the electric motor once and verify that the electric motor is rotating in the same direction as the arrow on the electric motor housing. If direction is incorrect, reverse two of the three leads on a 3-phase electric motor. D & H-ak power units are tested and relief valve is set at maximum pressure of the pump/motor combination. V-ak power units are tested and pressure control valves are factory preset. If adjustments are needed, follow the procedure below: egin adjusting relief valve and pump compensator control valve to increase pressure gradually. (NOE: lways set relief valve 250 SI higher than pump compensator pressure control valve or severe overheating will occur.) If pump fails to prime, vent pump discharge to atmosphere to establish fluid flow. Reservoir temperature should not exceed 150 F. System reliability and component service life will be reduced when system is operated at higher temperature. Clean fluid = improved system reliability and longer component service life, change filter elements whenever filter indicators indicate a dirty element condition. It is recommended that every 4,000 operating hours or once a year, whichever occurs first, the filler/ breather cap and suction strainer should be replaced. Fluid Recommendations remium quality hydraulic oil with a viscosity range between 150-250 SSU (30-50 cst.) at 100 F (38 C). Normal operating viscosity range between 80-1000 SSU (17-180 cst.). Maximum start-up viscosity is 4000 SSU (1000 cst.). NOE: Consult arker when exceeding 160 F (71 C) operation. Oil should have maximum anti-wear properties, rust and oxidation treatment. Filtration For maximum pump and system component life, the system should be protected from contamination at a level not to exceed 125 particles greater than 10 microns per milliliter of fluid. (SE Class 4 / ISO 16/13.) Due to the nature of variable displacement pumps, variations in pump inlet conditions, fluid acceleration losses, system aeration, and duty cycle must be carefully considered before specifying suction line filtration. Contact your arker representative for assistance. NOE: For additional information refer to ulletin No. IG-2600-550-001M1. 40 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU echnical Information Vertical ower Units Volume ump Mounting Control dapters he totally enclosed pump mounting bracket offers precision shaft alignment and safety from the rotating shafts and coupling. he bracket is designed to mount on the motor face with the motor coupling half secure to the shaft. hen the pump, with its coupling half secure on the pump shaft, is mounted and the coupling halves are engaged. his will require proper spacing of the coupling prior to installation and a coupling with an outside diameter less than dimension. If the coupling selected cannot be assembled this way, both coupling halves must be installed on the motor shaft. Next, mount the adapter on the motor. hen the pump can be mounted and the coupling secured to the pump by using the access slot to tighten the pump shaft coupling set screw. Dimensions* ump Mounting dapter SYLE 1 DER (SEE CHR FOR MOUNING ORIENION) CCESS SLO M DI HRU EQULLY SCED ON C1 DI..C. (4 LCES) 45 CCESS SLO SYLE 2 DER (VERICL MOUN ONLY) M DI HRU EQULLY SCED ON C2 DI..C. (4 LCES) 45 DI. D DI. DI. DI. G G DI. D DI. DI. DI. G G FCE O FCE FCE O FCE (56C FRME) H HRED 2 LCES FCE O FCE M DI HRU EQULLY SCED ON C1 DI..C. (4 LCES) H HRED 2 LCES Model ump Motor Face to Vertical Horizontal C1 C2 D G H M Number Mounting Mounting Face Mounting Mounting Style Weight 876631 SE 56C 6.7 5.0 5.88 N/ 4.50 3.50 1.63 3/8-16 0.44 2.00 YES YES 1 3 lb. 876632 SE 182C/256C 9.0 5.3 7.25 N/ 8.50 5.00 1.63 3/8-16 0.56 2.00 YES YES 1 4 lb. 876633 SE 56C 6.7 5.0 5.88 N/ 4.50 4.25 2.10 3/8-16 0.44 3.25 YES YES 1 4 lb. 876634 SE 182C/256C 9.0 5.3 7.25 N/ 8.50 5.00 2.10 3/8-16 0.56 3.25 YES YES 1 4 lb. 876635 SE 182C/256C 9.0 5.3 7.25 N/ 8.50 5.88 2.10 3/8-16 0.56 3.25 YES YES 1 5 lb. 875343 SE 182C/256C 11.4 9.0 7.25 10.25 8.50 5.75 2.88 1/2-13 0.53 4.00 YES NO 2 7 lb. 875344 SE 182C/256C 11.4 9.0 7.25 10.25 8.50 6.81 2.88 1/2-13 0.53 4.00 YES NO 2 8 lb. 876683 SE 182C/256C 9.0 8.8 7.25 N/ 8.50 6.38 2.88 1/2-13 0.53 4.00 NO YES 1 7 lb. 876684 SE C 182C/256C 9.0 9.3 7.25 N/ 8.50 6.69 3.56 5/8-11 0.53 5.00 NO YES 1 20 lb. * ll dimensions are in inches. NOE: It is the responsibility of the user to check the listed dimensions to ensure suitability of mounting adapter with pump/coupling/motor combination. 41 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee
Catalog HY13-1552-001/N,EU pplication Formulas 1 GM at 1500 SI = 1 H (General Rule) 1 Gallon = 231 Cubic Inches (3.7854 Liters) 1 Gallon Oil = 7.08 Lbs. 1 bar = 14.5 SI 25.4mm = 1 Inch Vertical ower Units Volume Conversion Control Equations 1 H = 42.4 U/Min. 1 Gallon = 3.7854 Liters H = GM x SI 1714 x ump Efficiency SI = 1714 x ump Efficiency x H GM GM = 1714 x ump Efficiency x H SI H = orque (in.-lbs.) x RM 63025 orque = H x 63025 RM RM = H x 63025 orque Motor Information t 440V 3-hase Motor Draws 1.25 M/H t 220V 3-hase Motor Draws 2.5 M/H t 110V Single hase Motor Draws 10 M/H 42 arker Hannifin Corporation Hydraulic ump/motor Division Greeneville, ennessee