LRM/5540/M, Roundline cylinder > > 3... 00 mm > > Clean line design > > Low friction, long life seals > > Standard magnetic piston for full control system versatility > > Non-lube operation > > Shock and vibration tested to EN 6373, Category, class A and B +80 C (+76 F) EN 6373-40 C (-40 F) Technical features Medium: Compressed air, filtered, lubricated or non-lubricated Operation: Double acting, magnetic piston, adjustable cushioning Operating pressure:... 0 bar (4... 45 psi) Cylinder diameters: 3... 00 mmm Strokes: See page below Non-standard strokes: On request Operating temperature: -40 C... +80 C (-40... +76 F) Air supply must be dry enough to avoid ice formation at temperatures below + C (+35 F). Materials: Barrel and end covers: anodized aluminium Piston rods: stainless steel (martensitic) Piston and piston rod seals: PUR O -rings: NBR Technical data Cylinder (mm) 3 40 50 63 80 00 Port size G /8 G /4 G /4 G 3/8 G 3/8 G / Piston rod (mm) 6 0 0 5 5 Piston rod thread M0x,5 Mx,5 M6x,5 M6x,5 M0x,5 M0x,5 Cushion length (mm) 9 4 4 7 34 Theoretical thrusts at 6 bar outstroke (N) 48 754 78 870 306 470 Theoretical thrusts at 6 bar instroke (N) 44 633 990 680 7 446 Air consumption at 6 bar outstroke (l/cm) 0,056 0,088 0,37 0,8 0,35 0,55 Air consumption at 6 bar instroke (l/cm) 0,048 0,074 0,4 0,95 0,3 0,5 Standard strokes Cylinder (mm) Strokes length (mm) 5 50 80 00 5 60 00 50 300 3 40 50 63 80 00 without notice, the specifications given in this document. (0 - B08B) 05 Norgren GmbH RW/en.5.073.0
RM/5540/M, Roundline cylinder Option selector Piston rod material Substitute Stainless steel martensitic R (standard) Hard chromium plated C Stainless steel austenitic S Cylinder (mm) Substitute 3 33 40 4 50 5 63 64 80 8 00 L M/554 / / Strokes (mm) 3000 max. Variants (magnetic piston) Standard Double ended piston rod Extended piston rod M/554/MU// Substitute M JM MU Extension (mm) RW/en.5.073.0 without notice, the specifications given in this document. (0 - B08B) 05 Norgren GmbH
RM/5540/M, Roundline cylinder Mountings 3... 63 mm 3 9 3 8 7 6 80... 00 mm 9 3 8 7 6 Cyl. AK B, G C F H L 7 8 3 3 QM/805/38 QM/553/ QM/553/ QM/805/5 QM/553/8 QM/553/4 40 QM/8040/38 QM/5540/ QM/5540/ QM/8040/5 QM/5540/8 QM/5540/4 50 QM/8050/38 QM/5550/ QM/5550/ QM/8050/5 QM/5550/8 QM/5550/4 63 QM/8050/38 QM/5563/ QM/5563/ QM/8050/5 QM/5563/8 QM/5563/4 80 QM/8080/38 QM/55480/ QM/55480/ QM/8080/5 QM/55480/8 QM/55480/4 00 QM/8080/38 QM/5540/ QM/5540/ QM/8080/5 QM/5540/8 QM/5540/4 Cyl. N UF Switch mounting Magnetically operated switches Service kit 3 6 9 3 M/P954 QM/805/3 QM/50/43/ LQM/55433/00 40 M/P955 QM/8040/3 QM/50/440/ LQM/5544/00 50 M/P956 QM/8050/3 QM/50/450/ LQM/5545/00 63 M/P956 QM/8050/3 QM/50/463/ LQM/55464/00 80 M/P34806 QM/8080/3 QM/50/480/ LQM/5548/00 00 M/P34806 QM/8080/3 QM/50/00/ LQM/554/00 without notice, the specifications given in this document. (0 - B08B) 05 Norgren GmbH RW/en.5.073.03
RM/5540/M, Roundline cylinder Basic dimensions 3... 63 mm WF ZB + D BF PL PL LB TC AM KW VD VA BG KW ø MM h9 ø B h9 ø BA h9 RT 80 and 00 mm KV SW WF L XH PL KV ZB + XL + D TC BF PL øtg AM VD VA BG FB KW ø MM h9 ø B h9 ø BA h9 RT KV SW L XH XL + BG # Stroke Cushion screw AM B/BA h9 BF BG BG D FB KV KV KW KW LB 3 30 M 30 x,5 30 6 36,5 G /8 M 0 x,5 7 36 5 8 4 40 4 38 M 38 x,5 35 8 45,5 G /4 M x,5 9 46 6 0 6 50 3 45 M 45 x,5 38 9,5 55,5 G /4 M 6 x,5 4 55 8 0 8 63 3 45 M 45 x,5 38 0 69,5 G 3/8 M 6 x,5 4 55 8 0 8 80 40 55 M 55 x,5 45 4 7,5 87,5 G 3/8 M8 M 0 x,5 30 0 00 40 55 M 55 x,5 45 4,5 07,5 G / M0 M 0 x,5 30 0 L MM h9 PL RT SW TC TG VA/ WF XH XL ZB kg at kg per Model VD 0 mm 00 mm 3 5,5 9 M 8 x 0 35 3 38 47 3 3 0,40 0,4 LRM/55433/ 40 7,5 6 M 0 x 3 44 3 45 57 4 54 0,83 0,7 LRM/5544/ 50 8,5 0 M x,5 7 54 3 50 6 5 64,30 0,3 LRM/5545/ 63 8,5 0 3 M 4 x,5 7 67 3 5 64 59 7,60 0,38 LRM/55464/ 80,5 5 5 M 6 x,5 85,5 70 5 6 76 96 3,0 0,59 LRM/5548/ 00,5 5 8,5 M 0 x,5 05,5 80 5 6 79,5 00,5 9 4,60 0,68 LRM/554/ Please insert stroke length. Cylinder variants RM/5540/JM Double ended piston rod L8 ZM Model 3 94 70 LRM/55433/JM/ 40 09 99 LRM/5544/JM/ 50 4 4 LRM/5545/JM/ 63 3 LRM/5546/JM/ 80 50 7 LRM/5548/JM/ 00 58 80 LRM/554/JM/ Please insert standard stroke length. ZM + x # L8 + # # Stroke Cushion screw RW/en.5.073.04 without notice, the specifications given in this document. (0 - B08B) 05 Norgren GmbH
RM/5540/M, Roundline cylinder Mountings Piston rod swivel AK Rear flange B, front flange G 3 4 MF UF TF 4 4 B F AH L L B F L L kg Model (AK) 3 4 3 M0x,5 5 6 73 0 9 7 30 0,0 QM/805/38 40 Mx,5 6 6 77 4 9 9 30 0,0 QM/8040/38 50/63 M6x,5 8 34 06 3 30 9 4 4 0,65 QM/8050/38 80/00 M0x,5 0 4 40 30 9 30 4 0,7 QM/8080/38 Foot C Piston rod clevis F Conforms to DIN ISO 840 CE LE RK CL CM CL FB R E AH E FB MF R TF UF kg Model 3 8 49 7 4 8 5 66 0, QM/553/ 40 33 58 9 5 30 60 80 0,9 QM/5540/ 50 40 70 9 5 40 70 90 0,5 QM/5550/ 63 45 80 9 5 50 76 96 0,33 QM/5563/ 80 56 00 8 0 50 0,8 QM/55480/ 00 66 0 4 8 30 70,0 QM/5540/ AT AH E ø CK h AU AO ø AB TR ER UF Z AB AH AO AT AU E TR UF kg Model 3 7 8 7 4 4 49 5 66 0,5 QM/553/ 40 9 33 0 5 0 58 60 80 0,44 QM/5540/ 50 9 40 0 5 0 70 70 90 0,59 QM/5550/ 63 9 45 0 5 0 80 76 96 0,73 QM/5563/ 80 56 5 5 45 00 63 90 0,67 QM/55480/ 00 4 66 0 5 45 0 75 3,00 QM/5540/ CE CK h CL CM ER LE RK kg Model (F) 3 M0x,5 40 0 0 0 6 0 8 0,09 QM/805/5 40 Mx,5 48 4 9 4 3 0,3 QM/8040/5 50/63 M6x,5 64 6 3 6 5 3 4,5 0,33 QM/8050/5 80/00 M0x,5 80 0 40 0 3 40 50 0,67 QM/8080/5 End cover trunnion H Rear hinge L G UT TL Z H CA ø TDh9 ø S K G4 G K G3 LH TDh9 TL UT kg Model 3 0 8 5 5 0,0 QM/553/8 40 9,5 63 6 0,03 QM/5540/8 50 4 76 6 0,05 QM/5550/8 63 6 3 93 8 0,07 QM/5563/8 80 8 3,5 8 0,09 QM/55480/8 00 0 3 3,5 0 0,5 QM/5540/8 CA G 3 4 S H K LH Z Model 3 35 0 4 40 8 7 4 0 46,5 59,5 0 36 QM/553/4 40 40 7 30 50 0 9 5 8 56,5 7 97 33 QM/5540/4 50 45 30 34 54 0 9 5 36 68,5 83 96 3 QM/5550/4 63 50 34 35 65 5 9 5 4 8,5 99 9 5 QM/5563/4 80 65 47,5 55 80,5 6 55 0,5 5,5 93 7 QM/55480/4 00 77 63 70 00 5 6 70,5 45,5 9 7 QM/5540/4 without notice, the specifications given in this document. (0 - B08B) 05 Norgren GmbH RW/en.5.073.05
RM/5540/M, Roundline cylinder Nose nut N Universal piston rod eye UF Conforms to DIN ISO 839 CN H 7 CE EN -0, KW Z Z ER LE AX KW kg Model 3 M30 x,5 36 8 0,03 M/P954 40 M38 x,5 46 0 0,06 M/P955 50/63 M45 x,5 55 0 0,08 M/P956 80/00 M55 x,5 60 3 0,5 M/P34806 Thread AX CE CN H7 EN- 0, ER LE Z kg Model 3 M0x,5 0 43 0 4 4 5 3 0,09 QM/805/3 40 Mx,5 50 6 6 7 3 0,3 QM/8040/3 50/63 M6x,5 8 64 6 5 0,33 QM/8050/3 80/00 M0x,5 33 77 0 5 5 6 5 0,67 QM/8080/3 Switch mounting QM/50/XXX/ 0 5 R 0 Magnetically operated switch Switch mounting bracket R max. Model 3 9 QM/50/43/3 40 33,5 QM/50/440/3 50 38,5 QM/50/450/3 63 45,5 QM/50/463/3 80 54,5 QM/50/480/3 00 64,5 QM/50/40/3 Technical data - Solid state - additional informations see data sheet N/en 4.3.007 Symbol pnp + BN BU A BK Voltage (V d.c.) Current maximum (ma) Function Operating temperature ( C) LED Protection class Plug Cable length (m) Cable type Weight (g) Model 0... 30 50 PNP -40... +80 IP67, 5 or 0 PVC 3 x 0, 37 M/50/EAP/V npn BU + BN A BK 0... 30 50 NPN -40... +80 IP67, 5 or 0 PVC 3 x 0, 37 M/50/EAN/V Insert cable length; ) Plug-in connector below; Color code: BK = black, BN = brown, BU = blue Drawings M/50/EAP/V, M/50/EAN/V Cable length L =, 5 or 0 m A-B 5, 30 A L +30 4 ±4 ø 6,4,5 B Warning These products are intended for use in industrial compressed air and rail transport systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. Fixing screw Color code: BK = black; BN = brown; BU = blue The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. RW/en.5.073.06 without notice, the specifications given in this document. (0 - B08B) 05 Norgren GmbH