CREEK Technical Services, LLC

Similar documents
CREEK Technical Services, LLC

PRODUCT EVALUATION Effective Date: July 1, 2014 RC-20

CREEK Technical Services, LLC

Product Evaluation Report

Code Compliance Research Report CCRR-0258

Equivalency Evaluation to 2010 FBC


William R. Heiden III, P.E.

Equivalency Evaluation to 2010 FBC

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: VELUX AMERICA LLC POST OFFICE 5001 GREENWOOD, SOUTH CAROLINA 29648

MAJESTIC SLATE CLASS A ECOSTAR GOLD STAR ROOF SYSTEM SPECIFICATIONS

PERFORMANCE TEST REPORT. Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent

Submittal Requirements for Product Evaluation - Doors

MAJESTIC NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM

TECHNICAL DATA SHEET Artisan Lap Siding

REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS INC ELM AVENUE FONTANA, CALIFORNIA EVALUATION SUBJECT:

Originally Issued: 09/26/2012 Revised: 09/29/2017 Valid Through: 09/30/2018

SENECA SHAKE TILES ECOSTAR GOLD STAR ROOF SYSTEM

3.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

Originally Issued: 09/09/2014 Revised: 09/13/2017 Valid Through: 09/30/2018

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: ITW BUILDEX

MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued May 1, Legacy report on the 1997 Uniform Building Code

MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: 2100 REXFORD ROAD CHARLOTTE, NORTH CAROLINA EVALUATION SUBJECT:

%"!#!#%&'!# %##(%)"&#%$!!%'"%!'*%% SW 26 Street, Room 208,%! '#%# - '

Maximum Span Tables. for Joists and Rafters. MSR Lumber. for Performance. Figure provided courtesy of the American Forest & Paper Association

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: NATURAL LIGHT ENERGY SYSTEMS

4.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology

ESR ICC Evaluation Service, Inc. Issued December 1, 2006 This report is subject to re-examination in one year.

EMPIRE NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM

STREAMLINED SOLAR CHECKLIST Owner Name:

National Evaluation Service, Inc.

REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9050 CENTRE POINTE DRIVE, SUITE 400 WEST CHESTER, OHIO EVALUATION SUBJECT:

Allowable Holes in VERSA-LAM Beams

Artisan Siding with Lock Joint System

EMPIRE SLATE ECOSTAR GOLD STAR ROOF SYSTEM

Clips, Bearing Plates and Fasteners for Standing Seam Panel Attachment

Clips, Bearing Plates and Fasteners for Standing Seam Panel Attachment

SFI SPECIFICATION 32.1 EFFECTIVE: MARCH 24, 2009 *

western for products manufactured in White City, Oregon

No clips required for this panel system

New Gateway 101/I.S.2/A440

MODEL 151B FIRE DAMPER

Inspection Services Design Appraisal Document

continuous mounting flange intended for direct attachment to roofing substrate.

Not to be distributed outside of FM Approvals and its affiliates except by Customer

Number: 161. Originally Issued: 06/24/2010 Revised: 08/03/2017 Valid Through: 06/30/2018

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: CONSOLIDATED SYSTEMS, INC. (CSi )

2.0 RAIL FREE SOLAR ROOF MOUNT. Utilizes EcoFasten Solar s patented technology

Quick Selection Guide

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

FLEMING-BARON DOOR PRODUCTS 101 Ashbridge Circle Woodbridge, Ontario L4L 3R5 UL CERTIFIED HURRICANE RESISTANT DOOR & FRAME PRODUCT

SFI SPECIFICATION 6.3 EFFECTIVE: FEBRUARY 26, 2014 *

ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

OV-1 STANDING SEAM OVERVIEW. Temple Architectural Products 638 Moore Rd Avon Lake, OH 44012

SFI SPECIFICATION 4.2 EFFECTIVE: OCTOBER 26, 1994*

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

SFI SPECIFICATION 6.1 EFFECTIVE: FEBRUARY 26, 2014 *

SFI SPECIFICATION 28.3 EFFECTIVE: APRIL 21, 2014 *

GENERAL PROVISIONS: Furnish and install one steel multi-platform motor truck scale and associated electronic controls.

ESR-1414 Reissued October 1, 2011 This report is subject to renewal in one year.

Trusted ICC ES. Conformity! Look. Evaluation. ICC-ES Evaluation

REVEAL SERIES ARCHITECTURAL DECK PRODUCTS

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

AFG501 ALUMINUM FEMA 361 LOUVER LOUVER TYPE RECOMMENDED SPECIFICATION

DIVISION: METALS SECTION: COLD-FORMED METAL FRAMING REPORT HOLDER: WARE INDUSTRIES D/B/A MARINO\WARE

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877)

Solar Power. Michael Arnold, LEED AP. ACI-NA Environmental Committee Meetings June 27, 2011

REVEAL SERIES ARCHITECTURAL DECK PRODUCTS CANADA

REVEAL SERIES ARCHITECTURAL DECK PRODUCTS UNITED STATES

EcoStar Majestic Slate Roofing System

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 *

This product is no longer manufactured.

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR'S OFFICE CONSTRUCTION SAFETY AND HEALTH STANDARD STANDARDS

SFI SPECIFICATION 39.2 EFFECTIVE: August 25, 2017 *

SOUTH AFRICAN NATIONAL STANDARD

DEPARTMENT OF TRADE AND INDUSTRY NO APRIL 2016

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 *

Purlins and Girts. A division of Canam Group

MM-L-751H August 13, 1970 SUPERSEDING Int. Fed. Spec. MM-L-00751G(Army-ME) July 3, 1967 and Fed. Spec. MM-L-751C May 20, 1942 FEDERAL SPECIFICATION

POWER RAIL TM P8. Assembly Instructions. step-by-step assembly and installation. Version 2, Rev A SP PCN

AlumaView AV200. A. Section Metal Fabrications: Miscellaneous for steel supports.

2507 (IBC 2006 ONLY) 3054 (IBC 2006 ONLY) Supreme Framing System Product Catalog

ESR-2408 Reissued August 2014 This report is subject to renewal August 2015.

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

EURO VISTA FOLD. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT

SOUTH AFRICAN NATIONAL STANDARD

SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 *

SOUTH AFRICAN NATIONAL STANDARD

PERFORMANCE SPECIFICATION SHEET BATTERY, RECHARGEABLE, NICKEL CADMIUM, VENTED, 1.2-VOLT, 13 AMPERE- HOUR, BB-475/A CELL

Applicable Requirements - NSPS Subpart JJJJ

DRYER EXHAUST VENT FLASHINGS

Transcription:

a Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6 TH EDITION (2017) Manufacturer: Issued March 19, 2018 2145 NW 115 th Street Miami, FL 33172 (305) 414-2705 www.alucom.com Manufacturing Plants: Quality Assurance: San Pedro Sula, Honduras Keystone Certifications, Inc. (QUA1824) SCOPE Category: Roofing Subcategory: Metal Roofing Code Sections: 1504.3 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) ALCM-015-02-01 TAS 125 2003 PRI Construction Materials Technologies (TST5878) ALCM-015-02-01 UL 580 2006 PRI Construction Materials Technologies (TST5878) ALCM-015-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST5878) ALCM-016-02-01 UL 580 2006 PRI Construction Materials Technologies (TST5878) ALCM-016-02-01 UL 1897 2012 LIMITATIONS 1. This evaluation is not for use in the HVHZ. 2. Fire classification is not within the scope of this evaluation. 3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC 4. The minimum roof slope shall be 3:12 or greater. 5. Reroofing shall be in accordance with FBC Section 1511. 6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7. Panels shall be installed in horizontal courses starting at the eave of the roof. Side laps shall be staggered between courses. 8. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. ALCM14001.4 FL15734-R6 Page 1 of 10

370mm[14.57in.] A PRODUCT DESCRIPTION Profile: Description: Material: Terrbella Shake Preformed, fastened, stone-coated steel panels Min. 26 ga.; min. F y = 40 ksi; ASTM A 792 or ASTM A 653 G90; Shall conform with FBC Section 1507.4.3 Profile: Description: Material: Terrabella Shingle Preformed, fastened, stone-coated steel panels Min. 26 ga.; min. F y = 40 ksi; ASTM A 792 or ASTM A 653 G90; Shall conform with FBC Section 1507.4.3 1340mm[52.75in.] 415mm[16.34in.] 1258mm[49.52in.] ALCM14001.4 FL15734-R6 Page 2 of 10

APPROVED ASSEMBLIES Terrabella Shake over plywood (Direct-to-Deck) Detail SA-A Maximum Design Pressures: Installed in accordance with FBC Nine (9) 0.131-inch x min. 2-3/8 ring shank nails per panel secured along back flange and nine (9) 0.131-inch x min. 2-3/8 ring shank nails per panel secured through the nose of the panel at the panel overlap as shown below. Fasteners shall be of sufficient length to penetrate through the deck a min. 3/8-inch and shall be corrosion resistant in accordance with sections 1507.4.4 and 1506.6. -67.5 psf D 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 30 ft B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 50 ft 40 ft NA C 60 ft 60 ft 60 ft 60 ft 40 ft 25 ft NA NA NA D 60 ft 60 ft 60 ft 40 ft 15 ft NA NA NA NA B 60 ft 60 ft 60 ft 50 ft 30 ft NA NA NA NA C 60 ft 50 ft 25 ft NA NA NA NA NA NA D 50 ft 20 ft NA NA NA NA NA NA NA Notes: 1) category for the structure location shall be as defined in the Florida Building Code 2) Limitations are based ALCM14001.4 FL15734-R6 Page 3 of 10

Terrabella Shake over plywood (Direct-to-Deck) Detail SA-B Maximum Design Pressures: Installed in accordance with FBC Six (6) #9-15 x min. 2-1/2 HWH wood screws per panel secured along back flange and six (6) #9-15 x min. 2-1/2 HWH wood screws per panel secured through the nose of the panel at the panel overlap as shown below. Fasteners shall be of sufficient length to penetrate through the deck a min. 3/8-inch and shall be corrosion resistant in accordance with sections 1507.4.4 and 1506.6. -71.25 psf D 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 40 ft B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 40 ft 30 ft C 60 ft 60 ft 60 ft 60 ft 60 ft 30 ft 15 ft NA NA D 60 ft 60 ft 60 ft 50 ft 25 ft NA NA NA NA B 60 ft 60 ft 60 ft 60 ft 40 ft NA NA NA NA C 60 ft 60 ft 30 ft 15 ft NA NA NA NA NA D 60 ft 30 ft NA NA NA NA NA NA NA Notes: 1) category for the structure location shall be as defined in the Florida Building Code 2) Limitations are based ALCM14001.4 FL15734-R6 Page 4 of 10

Terrabella Shake over plywood (Direct-to-Deck) Detail SA-C Maximum Design Pressures: Installed in accordance with FBC Eight (8) #9-15 x min. 2-1/2 HWH wood screws per panel secured along back flange and eight (8) #9-15 x min. 2-1/2 HWH wood screws per panel secured through the nose of the panel at the panel overlap as shown below. Fasteners shall be of sufficient length to penetrate through the deck a min. 3/8-inch and shall be corrosion resistant in accordance with sections 1507.4.4 and 1506.6. -112.5 psf D 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft D 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 40 ft 25 ft B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 40 ft C 60 ft 60 ft 60 ft 60 ft 60 ft 40 ft 25 ft 15 ft NA D 60 ft 60 ft 60 ft 60 ft 30 ft 15 ft NA NA NA Notes: 1) category for the structure location shall be as defined in the Florida Building Code 2) Limitations are based ALCM14001.4 FL15734-R6 Page 5 of 10

Terrabella Shake over wood battens Detail SA/B-A Battens: Maximum Design Pressures: Installed in accordance with FBC Nominal 1x4 No.2 SYP wood battens shall be installed continuously (end-to-end) and parallel to eave, starting at the eave with two (2) 0.131-inch x min. 2-1/2-inch ring shank nails secured a maximum 12-inch o.c. while ensuring attachment into the truss/rafter at each intersection. Battens shall be spaced 14.5-inch o.c. up the slope of the roof. Fasteners shall be corrosion resistance in accordance with sections 1507.4.4 and 1506.6. Nine (9) 0.131-inch x 2-3/8-inch ring shank nails per panel secured along back flange and nine (9) 0.131-inch 2-3/8-inch ring shank nails per panel secured through the nose of the panel at the panel overlap into wood battens as shown below. Fasteners shall be corrosion resistant in accordance with section 1507.4.4. -82.5 psf Continued on Next Page ALCM14001.4 FL15734-R6 Page 6 of 10

Terrabella Shake over wood battens Detail SA/B-A (Continued) D 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 50 ft C 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 30 ft 20 ft NA D 60 ft 60 ft 60 ft 60 ft 60 ft 30 ft 15 ft NA NA B 60 ft 60 ft 60 ft 60 ft 60 ft 40 ft 30 ft NA NA C 60 ft 60 ft 60 ft 30 ft 15 ft NA NA NA NA D 60 ft 60 ft 30 ft NA NA NA NA NA NA Notes: 1) category for the structure location shall be as defined in the Florida Building Code 2) Limitations are based ALCM14001.4 FL15734-R6 Page 7 of 10

Terrabella Shingle over plywood (Direct-to-Deck) Detail SI-A Maximum Design Pressures: Installed in accordance with FBC Eight (8) #9-15 x min. 2-1/2 HWH wood screws per panel secured along back flange and eight (8) #9-15 x min. 2-1/2 HWH wood screws per panel secured through the nose of the panel at the panel overlap as shown below. Fasteners shall be of sufficient length to penetrate through the deck a min. 3/8-inch and shall be corrosion resistant in accordance with sections 1507.4.4 and 1506.6. -67.5 psf D 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 30 ft B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 50 ft 40 ft NA C 60 ft 60 ft 60 ft 60 ft 40 ft 25 ft NA NA NA D 60 ft 60 ft 60 ft 40 ft 15 ft NA NA NA NA B 60 ft 60 ft 60 ft 50 ft 30 ft NA NA NA NA C 60 ft 50 ft 25 ft NA NA NA NA NA NA D 50 ft 20 ft NA NA NA NA NA NA NA Notes: 1) category for the structure location shall be as defined in the Florida Building Code 2) Limitations are based ALCM14001.4 FL15734-R6 Page 8 of 10

Terrabella Shingle over plywood (Direct-to-Deck) Detail SI-B Installed in accordance with FBC Six (6) #9-15 x min. 2-1/2 HWH wood screws per panel secured along back flange and six (6) #9-15 x min. 2-1/2 HWH wood screws per panel secured through the nose of the panel at the panel overlap. Fasteners shall be of sufficient length to penetrate through the deck a min. 3/8-inch and shall be corrosion resistant in accordance with sections 1507.4.4 and 1506.6. Maximum Design Pressures: -97.5 psf D 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft C 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 50 ft 30 ft D 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 40 ft 20 ft NA B 60 ft 60 ft 60 ft 60 ft 60 ft 60 ft 50 ft 30 ft NA C 60 ft 60 ft 60 ft 60 ft 40 ft 20 ft NA NA NA D 60 ft 60 ft 60 ft 30 ft 15 ft NA NA NA NA Notes: 1) category for the structure location shall be as defined in the Florida Building Code 2) Limitations are based ALCM14001.4 FL15734-R6 Page 9 of 10

COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6 th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT ALCM14001.4 FL15734-R6 Page 10 of 10