AFG501 ALUMINUM FEMA 361 LOUVER LOUVER TYPE RECOMMENDED SPECIFICATION
|
|
- Gordon Cameron
- 5 years ago
- Views:
Transcription
1 LOUVER TYPE AFG501 ALUMINUM FEMA 361 LOUVER Visible Mullion Louver Type... AFG501 Blade Material... Extruded Aluminum, Alloy 6061-T6 Blade in. (6.35 mm) Frame Material... Formed Aluminum, Alloy 5052-H32 Frame in. (6.35 mm) Louver Depth in. (139.7 mm) Free Area 4 ft. x 4 ft. Unit sq. ft. (0.70 m 2 ) Percent Free Area % Free Area Velocity at Beginning Point of Water Penetration 0.01 oz H 2 O/sq. ft. Free Area.... 2,002 fpm (10.17 m/s) Air Volume Flow Rate at Beginning Point of Water Penetration 4 ft. x 4 ft. Unit ,115 cfm (7.13 m 3 /s) Pressure Drop at Beginning Point of Water Penetration in. H 2 O (0.027 kpa) Maximum Qualified Wind Design Load*.... ± 250 PSF (11.97 kpa) Bird Screen in. flattened expanded aluminum Construction....Welded Shown as channel frame recessed/flush mount (default) RECOMMENDED SPECIFICATION *Width and height dimensions undersized 1 /2 inch unless configured actual size. (Actual size selection only available on recessed/flush mount configuration) GENERAL Furnish and install where indicated on plans or described in schedules FEMA Louver Type AFG501 as designed and manufactured by The Airolite Company LLC, Schofield, Wisconsin. Louvers shall be AMCA certified and tested per FEMA , FEMA and ICC for depbirs impact only. Furnish louvers with bird screen, installation hardware and finishes as specified and as required for a complete installation. SUBMITTALS Manufacturer shall submit shop drawings incorporating key plans, elevations, sections and details showing profiles, angles and spacing of louver blades and frames; unit dimensions related to wall openings and construction; and, anchorage details and locations. For each type of product specified, submit free area, air performance, water penetration ratings. Provide samples of manufacturer s finish and color charts showing the standard colors available. PRODUCTS Louvers shall be FEMA Louver Type AFG501 with visible mullions and shall be AMCA Certified and tested to FEMA , FEMA and ICC standards for storm shelter and safe rooms for debris impact only, which simulates a 15 lb 2x4 travling at 100 mph. Louvers shall be 5.5-inches (139.7 mm) deep and assembled entirely from extruded and formed aluminum components. Blades and frames shall be 0.25-inch (6.35 mm) thick. Blades shall be horizontal, inverted-vtype. WELDED ASSEMBLY Join stationary blade, head, sill and jamb frames with welds concealed from view. Louver blades shall be joined to each jamb frame with fillet welds produced with the Pulsed Gas Metal Arc Welding (GMAW/Mig) process. STRUCTURAL DESIGN CRITERIA Manufacturer shall design and furnish all supports required to withstand a wind force of not less than 250 pounds per square foot and tested to FEMA , FEMA and ICC standards for storm shelter and safe rooms for debris impact only. FEMA Grilles larger than 84.5-inches (215 cm) wide x inches (306 cm) high or inches (306 cm) wide x 84.5-inches (215 cm) high will be fabricated and installed in multiple sections. Louver blades, frames, mullions and anchorages shall be demonstrated to withstand the specified wind design load. PERFORMANCE RATINGS FREE AREA: 7.55 Square Feet (0.70 m 2 ) MINIMUM FREE AREA VELOCITY at Beginning Point of Water Penetration: 2,002 fpm (10.17 m/s) MINIMUM AIR VOLUME FLOW RATE at Beginning Point of Water Penetration: 15,115 cfm (7.13 m 3 /s) MAXIMUM STATIC PRESSURE at Beginning Point of Water Penetration: 0.11 in. H 2 O (0.027 kpa) See page 13 for complete finish options
2 LOUVER TYPE AFG501 PRODUCT DESCRIPTION & DETAILS AIROLITE LOUVER TYPE AFG501 is a 5.5-inch (140 mm) deep, severe duty extruded aluminum louver designed to protect exterior wall penetrations on FEMA 320 or 361 compliant storm shelters or safe rooms. Louver type AFG501 may be installed in any exterior wall penetration that requires protection. Design incorporates inverted V style blades which lend high free area and very little airflow resistance while providing maximum protection against extremely high wind loads and wind-borne debris. Louver Type AFG501 withstands wind loads up to ±250 PSF (11.97 kpa) and tested per FEMA , FEMA , and ICC for debris impact only, which simulates a 15 lb. 2 x 4 traveling at 100 MPH. Airolite Louver Type AFG501 has AMCA Licensed air performance and water penetration ratings that enable designers to select and specify this product with confidence. Please contact your local Airolite representative or the factory for assistance. INSTALLATION DETAILS - CHANNEL FRAME RECESSED/FLUSH MOUNT (DEFAULT) Minimum Rough Opening Section Size: 12 in. (30 cm) W x 12 in. (30 cm) H Maximum Rough Opening Section Size: in. (306 cm) W x in. (306 cm) H (one dimension limited to 84.5 in.) INSTALLATION DETAILS - FLANGE FRAME RECESSED/FLUSH MOUNT Minimum Rough Opening Section Size: 12 in. (30 cm) W x 12 in. (30 cm) H Maximum Rough Opening Section Size: in. (306 cm) W x 112 in. (285 cm) H (one dimension limited to 76 in.)
3 LOUVER TYPE AFG501 PRODUCT DETAILS RECESSED/FLUSH MOUNT
4 LOUVER TYPE AFG501 PRODUCT DETAILS RECESSED/FLUSH MOUNT
5 LOUVER TYPE AFG501 PRODUCT DETAILS RECESSED/FLUSH MOUNT
6 LOUVER TYPE AFG501 PRODUCT INSTALLATION DETAILS
7 LOUVER TYPE AFG501 PRODUCT INSTALLATION DETAILS RECESSED/FLUSH MOUNT
8 LOUVER TYPE AFG501 PRODUCT INSTALLATION DETAILS RECESSED/FLUSH MOUNT
9 LOUVER TYPE AFG501 PRODUCT DETAILS INSTALLATION DETAILS - CHANNEL FRAME CANTILEVERED Minimum Rough Opening Section Size: 12 in. (30 cm) W x 12 in. (30 cm) H Maximum Rough Opening Section Size: 117 in. (297 cm) W x 76 in. (193 cm) H or 76 in. (193 cm) W x 112 in. (285 cm) H
10 LOUVER TYPE AFG501 PRODUCT DETAILS CANTILEVER MOUNT
11 LOUVER TYPE AFG501 PRODUCT INSTALLATION DETAILS
12 Louver Height Inches LOUVER TYPE AFG501 PERFORMANCE RATINGS FREE AREA CHART - in square feet Louver Width Inches The Airolite Company LLC certifies that the AFG501 louvers shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. Airflow Resistance (Standard Air lb/ft 3 ) Water Penetration (Test Size 48 in. x 48 in. Test Duration of 15 min.) Model AFG501 resistance to airflow (pressure drop) varies depending on louver application (air intake or air exhaust). Free area velocities (shown) are higher than average velocity through the overall louver size. (Tested to AMCA Figure 5.5) The AMCA Water Penetration Test provides a method for comparing various louver models and designs as to their efficiency in resisting the penetration of rainfall under specific laboratory test conditions. The beginning point of water penetration is defined as that velocity where the water penetration curve projects through 0.01 oz. of water (penetration) per sq. ft. of louver free area. *The beginning point of water penetration for Model AFG501 is 634 fpm free area velocity. These performance ratings do not guarantee a louver to be weather-proof or stormproof and should be used in combination with other factors including good engineering judgement in selecting louvers.
13 LOUVER TYPE AFG501 FASTENER CHART SUBSTRATE REQUIREMENTS (by others): Substrate Min. Type Min. Thickness Min. Edge Distance Min. Embedment Steel A36, Fy 36 ksi [248 MPa] 12 Ga [2.65 mm] If Nut Not Used: 0.11 in [2.84 mm] 2x Fastener diameter Aluminum Fy 9.5 ksi [65.5 Mpa] 1/4" [6.35 mm] If Nut Not Used: 0.25 in [6.35 mm] Concrete 2000 psi [13.8 MPa] 6" [152 mm] 3" [76 mm] or 5" [127 mm] Block Grade N, Type 2, ASTM C90 6" [152 mm] 2.5" [6.35 mm] CMU 5" [76 mm] Grout 2000 psi [13.8 MPa] Fill Block Cavity FASTENER REQUIREMENTS: Substrate Flush Mount Fastener Type Flange Mount Fastener Type Steel & Aluminum Concrete & Grout Filled CMU 3/8 16 Gr 5 ZP Bolt/Nut or 1/2 13 SS Bolt/Nut 1/2" [12.7 mm] Plated or SS Red Head LDT or Equivalent FASTENER ON CENTER REQUIREMENTS: Mount Style Max On Center Head & Sill Mount 8" [203 mm] between 1st and 2nd hole, and 12" [305 mm] thereafter Jamb Mount 12" [305 mm] Equation Value MULLION CHANNEL DEPTH CHART: Equation = (Nom Height in inches)*(square Root of the Nominal Width Per Section in inches)/144 Mullion Channel Overall Depth 5.5" [140 mm] 8.0" [203 mm] 10.5" [267 mm] 13.0" [330 mm] 15.5" [394 mm] 18.0" [457 mm] 21.25" [540 mm] 3/8 16 Gr 5 ZP Bolt/Nut or 3/8 16 SS Bolt/Nut 1/2" [12.7 mm] Plated or SS Redhead LDT or Equivalent FINISHES (Select one of the following) ACRYLIC ENAMEL: Louvers shall be cleaned, pretreated and Finished with an oven-cured thermosetting acrylic enamel finish that meets or exceeds the performance requirements of AAMA 2603, Voluntary Specification Performance Requirements and Test Procedures for Pigmented Organic Coatings. 2-COAT FLUOROPOLYMER: Louvers shall be cleaned, pretreated and Finshed with an inhibitive primer and oven-cured Kynar 500 / Hylar 5000 resin coating with minimum 1.2 mils dry-film coating thickness that meets or exceeds the performance requirements of AAMA 2605, Voluntary Specification, Performance Requirements and Test Procedures for Superior Performance Organic Coatings on Aluminum Extrusions and Panels. 3-COAT FLUOROPOLYMER: Louvers shall be cleaned, pretreated and Finished with an inhibitive primer and oven-cured Kynar 500 / Hylar 5000 resin coating with minimum 2.0 mils dry-film coating thickness that meets or exceeds the performance requirements of AAMA 2605, Voluntary Specification, Performance Requirements and Test Procedures for Superior Performance Organic Coatings on Aluminum Extrusions and Panels. Submittal AFG501 September 2017 Copyright 2017 The Airolite Company, LLC The Airolite Company, LLC reserves the right to make product changes.
AFL-501. Aluminum FEMA 361 Louver Chevron Blade Application and Design
FEMA 361 Louver Chevron Blade Application and Design is an aluminum louver designed to protect exterior wall penetrations on FEMA 361 or FEMA 320 compliant storm shelters or safe rooms. Design incorporates
More informationFSG-801. Fabricated Steel FEMA 361 Grille Chevron Blade. Application and Design. Standard Construction
FEMA 361 Grille Chevron Blade Application and Design is a severe duty fabricated steel grille designed to protect exterior wall penetrations on FEMA 320 or 361 compliant storm shelters or safe rooms. Most
More informationMODEL OAL. Water Penetration. Water Penetration. Free Area OAL PERFORMANCE REGISTERS GRILLES &
MODEL OAL The OAL series of etruded aluminum stationary louvers is manufactured for installation in eterior wall openings. They are designed to allow fresh air and ehaust air to flow into/out of the building
More informationSTATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS
STATIONARY LOUVERS 14 15 STATIONARY LOUVER STATIONARY LOUVER SSL - 100 SSL SERIES SSL SERIES [SSL - 100, SSL - 110, SSL - 120] Air Performance Pressure Drop SSL - 100 Stationary Louver is a weather louver
More informationInsulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.
R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and
More informationInsulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel
Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and
More informationModel VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.
Model Application The is a low leakage high performance control damper with extruded aluminum airfoil blades. Blades are completely contained within the frame allowing the damper to be directly mounted
More informationBaked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)
Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure
More informationInsulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)
R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken blade to eliminate the transfer of heat or cold penetration and reduced
More informationModel VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options
Application The series is a general purpose control damper for applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. A wide range of electric
More informationSECTION DUCTWORK ACCESSORIES
SECTION 15910 DUCTWORK ACCESSORIES PART 1- GENERAL SCOPE This sections includes accessories used in the installation of duct systems. Included are the following topics: PART 1- GENERAL Related Work Reference
More informationThermal Isolation. Break
Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade will minimize the transfer of thermal energy and reduces condensation.it
More informationSD-1250 and SD-1600 Series Smoke Dampers
SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke
More informationLouver Products Severe Duty, Stationary, Operable
Louver Products Severe Duty,, Operable November 2017 Louver Selection Guide In an effort to help located and select the louver you need, this catalog organizes the more than 100 standard Greenheck louver
More informationModel VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options
Application and Design The series is a general purpose, low leakage control damper intended for application in low pressure and velocity systems. atings Pressure: 2 in. wg (.5 kpa) - pressure differential.
More informationAir Louvers OFAL 300 SERIES
Fresh / Exhaust Model : OFAL GI 359 Description: Stationary Louvers is designed to provide air intake and air exhaust openings in building exterior walls to protect against the direct ingress of rain.
More informationModel CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I
Application and Design Model is a combination fire smoke damper that is UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model s operational ratings
More informationThermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed
Application The is a low leakage thermally insulated damper with extruded airfoil blades. features broken blade which minimized the transfer of thermal energy and reduce condensation. It s also IECC (International
More informationModel DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating
Application Model is a multi-blade fire damper with 3V style blades. The has been qualified to 4000 fpm (20.3 m/s) and 10 in. wg (2.5 kpa) for dynamic closure in emergency fire situations. Model may be
More informationModel VCD-43 Extruded Airfoil Blade Control Damper
Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure
More informationWD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.
Application The WD200 series are electrically motorized backdraft dampers that open when energized and spring return close when deenergized. The WD200 series are for horizontal or vertical mounting. Primary
More informationCONTROL DAMPERS. Models 1810 & Model Model Model 1370
CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and
More informationSP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type
1 SUBMITTAL DATA Series 1000 Air-Foil Control Damper SP Standard Profile 2" 50.8 mm In Duct or Flanged to Duct Install Types 4" 101.6 mm 6.4" 162.6 mm blades fully open 1" 25.4 mm Extended Rear Flange
More informationVCD-23. Flange Options. Size Limitations
Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators
More informationSMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.
Application Model is a leakage rated modulating smoke damper with 3V style blades. The has been qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operational closure in emergency smoke control
More informationCentrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved
Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability
More informationPC-125x Counter-Balanced Backdraft Damper
PC-15x Counter-Balanced Backdraft Damper Product Bulletin Code No. LIT-101180 Issued April 7, 015 Refer to the QuickLIT Web site for the most up-to-date version of this document. Since 1885, Johnson Controls
More informationWD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.
Application and Design The WD300 series dampers are designed to prevent reverse airflow in horizontal exhaust applications. The WD300 features a pressure sensitive blade design that opens and remains open
More informationCentrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved
Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the
More informationFBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.
Application and Design The is a vertical style face and bypass low leakage damper. This model is intended for application in medium to high pressure and velocity systems. Smooth profile extruded aluminum
More informationModel VCD-20 3V CONTROL DAMPER
R Application and Design The series is a ruggedly built general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium
More informationModel SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.
Model Application The is a leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper
More informationSECTION AXIAL HVAC FANS
SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationHCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationHCD-230 Industrial Control Damper
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationCONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7
CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy
More informationVCD-23. Low Leakage CONTROL DAMPER
Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators
More informationTED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 APPLICATION Ruskin model TED50XT is a low leak, thermally efficient damper with insulated extruded aluminum blades specially
More informationModel SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating
R Model Application Model is a 304SS combination fire smoke damper with 3V style blades. The is qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa). This damper may be installed vertically (with blades
More informationModel FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.
Application Model is a combination fire smoke damper with 3V style blades. This model is designed for operation and dynamic closure in emergency fire smoke situations. It is rated for airflow and leakage
More informationSMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.
Application Model is a leakage rated smoke damper with 3V style blades. The has been qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operational closure in emergency smoke control situations.
More informationModel SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation
Application and Design The is a severe environment 316SS ultra low leakage control damper with rugged stainless steel airfoil blades designed to meet the highest standards established for commercial control
More informationBC 08. Sand Trap Louvers STL-AB-11A LISTED
BC 08 Sand Trap Louvers STL-AB-11A Table Of Contents S. No Description Page No 1 General Information 1 2 Various Models 2 3 STL - B-10 Series 4 STL - BC-20 Series 3 4 5 6 STL - B-30 Series STL - B-40 Series
More informationModel FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features
Application Model is a high performance combination fire smoke damper with Class I leakage. High strength airfoil blades ensure the lowest resistance to airflow in HVAC systems with velocities to 4000
More informationVCD-23 Low Leakage CONTROL DAMPER
Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric actuators are available.
More informationModel SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features
Model Application The is a leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper and smoke
More informationModel VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.
Application and Design The Series is a ruggedly built low leakage control damper with thermally insulated blades. The is intended for application in medium pressure and velocity systems. This model also
More informationPositive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS
BACKDRAFT DAMPERS BLADE OPTION: SR: 0.016-0.020 roll formed aluminum with vinyl gasket - used with fan motors under 1 HP SE: 0.05 extruded aluminum with vinyl gasket - used with fan motors over 1 HP Positive
More informationModel FSD-212. Combination FIRE SMOKE DAMPERS
R APPLICATION Model is a combination fire smoke damper with 3V style blades. The has been qualified to 2000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operation and dynamic closure in emergency fire smoke
More informationArchitectural Louvers
Architectural Louvers Introduction AWV is headquartered in Holland, Ohio and is part of the Mestek Architectural Group. In addition to AWV, Mestek s Architectural activities include Linel and a strategic
More informationARROW INDUSTRIAL PRODUCTS
IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products
More informationAMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options
Application and Design The combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that both measures and regulates airflow volumes
More informationModel FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating
R APPLICATION Model FSD-211 is a combination fire smoke damper with 3V style blades. The FSD-211 has been qualified to 2000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operation and dynamic closure in emergency
More informationFSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD60, FSD60LP CoMINAtIoN FIRe AND SMoKe DAMPeR 1 1 /2 HoUR UL555 RAteD, UL555S LeAKAge CLASS 1 APPLICAtIoN Ruskin FSD60 Series
More informationAMD-33 Air Measuring Station with VCD-33 Control Damper
Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized
More informationModel FSD-331 Combination Fire Smoke Dampers
R APPLICATION Model is a high performance combination fire smoke damper with class I leakage. High strength airfoil blades ensure the lowest resistance to airflow in HVAC systems with velocities to 4000
More informationBlast Protection Damper
Protection Damper plate shown as transparent height width 250mm wide 6.35mm thick blast plate bolted to damper frame 178mm 250mm standard depth 76mm standard flange Application The damper is designed for
More informationAD-1251 Probe with Differential Pressure Transducer
AD-1251 Probe with Differential Pressure Transducer Product Bulletin Code No. LIT-12011473 Issued October 31, 2011 Supersedes September 6, 2011 The AD-1251 Probe with Differential Pressure Transducer (DPT)
More informationVCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:
Application and Design is a low leakage damper with vertical blade orientation designed to meet the highest standards established for commercial control dampers. The is intended for application in medium
More informationA. This Section includes the following types of sectional overhead doors:
SECTION 08361 - SECTIONAL OVERHEAD DOORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationAMD-42V Air Measuring Station with VCD-42V Control Damper
Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade
More informationAMD-42 Air Measuring Station with VCD-42 Control Damper
Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple
More informationModel VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.
Application and Design The series is a vertical blade general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium
More informationLINEAR DIFFUSERS AND BAR GRILLES
49-240 48LL1 49-280 49-480 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance. Linear bar grilles offer a choice
More informationOutside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL
Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL OHCL Outside Horizontal Closable Louvers - mm Curved Profile 226-228F OHCL 124 Outside Horizontal Closable Louvers
More informationSpecifications... Quick Spec Guide...
TABLE OF CONTENTS Specifications........................................... Quick Spec Guide....................................... Elevations/Sizes: 1/4" Scale Full Awning Units..................................
More informationTubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct
Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-
More informationFSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD36, FSD36LP COMINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2 APPLICATION Ruskin FSD36 Series
More informationSubmittal Requirements for Product Evaluation - Doors
TEXAS DEPARTMENT OF INSURANCE Engineering Services / MC 103-3A 333 Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 322-2212 Fax No. (512) 463-6693 Submittal Requirements for Product
More informationModel VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations
Application and Design The series is an ultra low leakage damper with rugged steel airfoil blades designed to meet the highest standards established for commercial control dampers. The airfoil shape reduces
More informationHVAC Control & Balancing Dampers
HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* 1June 2017 Design and Construction Features Bearing Shaft Extension Jamb Seal Commercial Control Dampers
More informationAlumaView AV200. A. Section Metal Fabrications: Miscellaneous for steel supports.
AlumaView AV200 PART 1 GENERAL 1.1 SECTION INCLUDES A. Commercial sectional doors. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Miscellaneous for steel supports. B. Section 08710 - Door
More informationAMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options
Application and Design Thermal Dispersion Air Measuring Station with VCD-42 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage
More informationFiltered Kitchen Supply Packaged Ventilator
Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................
More informationAD-1250 Airflow Measuring Station
AD-1250 Airflow Measuring Station Product Bulletin Code No. LIT-12011472 Issued March 2016 Refer to the QuickLIT website for the most up-to-date version of this document. The AD-1250 Airflow Measuring
More informationCentrifugal Filtered Supply Roof Blowers
CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................
More informationAir Measuring Products AMD AMS IAQ
Air Measuring Products AMD AMS IAQ January 1 2012 Air Measuring Products Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. By measuring the
More informationBlast Protection Damper
height width 250mm standard 76mm standard flange Application The damper is designed for protection against sudden blasts and instantaneous pressure changes. Vertical and horizontal mounting applications
More informationRM-1200 Slim Round Control Damper
RM-1200 Slim Round Control Damper Product Bulletin Code No. LIT-12011358 Issued June 16, 2008 Since 1905, Johnson Controls has developed and refined air control products by providing the highest quality
More informationAir Measuring Products. AMS Thermal Dispersion Pressure Differential
Air Measuring Products AMS Thermal Dispersion Pressure Differential August 2014 1 Airflow Measuring Technologies Greenheck airflow measuring products are available with either differential pressure based
More informationDimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty
Submittal Data Model PELV-100 Penthouse Elevator Vented Hood Application and Design The PELV-100 Penthouse Elevator Vented Hood is a gravity ventilator penthouse with an 18" x 18" gasketed access door
More informationA Complete Line of Quality Products for Marine Applications
american warming and ventilating A Mestek Company A Complete Line of Quality Products for Marine Applications 1 About AWV Marine Dampers At American Warming and Ventilating, we are committed to design
More informationPremium Correctional Air Distribution. The First Name in Air Diffusion.
Premium Correctional Air Distribution The First Name in Air Diffusion www.anemostat.com PRODUCT DIRECTORY APPLICATIONS Stainless Steel S-Vent MAXIMUM SECURITY GRILLES NEW CONSTRUCTION page 16 page 4 &
More informationAMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers
AMCA MEMBER American Warming and Ventilating A Mestek Company Quality Air Control Dampers Over a century of dedication to quality products and customer satisfaction has enabled American Warming and Ventilating
More informationSliding Patio Doors Flat Casing Vinyl
TABLE OF CONTENTS Specifications... 5-2 QuickSpecGuide... 5-3 Elevations/Sizes: 1/4 Scale 2-PanelSlidingPatioDoors... 5-4 2-PanelSlidingPatioDoorswithTransoms... 5-5 Transoms... 5-7 Sidelights... 5-9 SectionDetails...
More informationMOTORIZED VOLUME DAMPER
MOTORIZED VOLUME DAMPER 1 a perfect partner in performance... Our Product Ranges Dampers 1 Fire Dampers 2 Fire / Smoke Dampers 3 Volume Control Dampers 4 Motorized Control Dampers 5 Pressure Relief Dampers
More informationMancoolers Models MCY, MCB, MCP
Mancoolers s MCY, MCB, MCP October 2007 Mancoolers Greenheck MC Mancooler fans are direct drive, tube axial fans designed for applications where localized air direction and circulation are required. Mancoolers
More informationF. VAV hoods shall have a restricted bypass plate.
1.01 SUMMARY A. Section Includes: 1. Laboratory fume hoods. B. Related Sections: 1. Section 6500 Laboratory casework 2. Section 15 Mechanical: Furnishing and installation of plumbing utilities and final
More informationInline and Roof Mounted Fans
CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive
More informationTwin City Fan & Blower
Twin City Fan & Blower BULLETIN 4050 November 2009 DOWNBLAST ROOF EXHAUSTERS TYPE DCRD / BCRD (Spun Aluminum Housing) TYPE BCRD-E (Endurex Polymeric Housing) Downblast Roof Exhausters Twin City Fan & Blower
More informationGeneral Information SECTION DIRECTORY
SECTION DIRECTORY General Information Product Summary... V-AW-2 Product Selection Guide... V-AW-3 Size and Performance Data... V-AW-3 Features and Options... V-AW-3 Sound Transmission Class and Outdoor-Indoor
More informationEXTRUDED ALUMINUM BALANCED DOORS AND ENTRANCES
WIKK INDUSTRIES, INC. MasterFormat 95 SECTION 08480 MasterFormat 04 SECTION 08 42 36 EXTRUDED ALUMINUM BALANCED DOORS AND ENTRANCES PART 1 GENERAL 1.1 DESCRIPTION A. Work included: Entrance and vestibule
More informationK SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS
K Series Direct Drive K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS SPECIFICATIONS Fans shall be direct drive propeller type with integral motorside OSHA style guard. Propeller construction shall be of
More informationDAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING
PUB. NO. 732-3 DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING The most widely used dampers in commercial HVAC applications Control Dampers - Extruded Aluminum
More informationRC/RR MODEL FLAP GATES GENERAL DESCRIPTION DESIGN CONSTRUCTION
GENERAL DESCRIPTION The Orbinox model RC and RR Flap Gates are designed for discharge lines such as levees, sewer lines and drainage conduits. The flap stays closed preventing water back-flow, and it opens
More informationEXTRUDED ALUMINUM TEMPERED GLASS BALANCED DOORS AND ENTRANCES
WIKK INDUSTRIES, INC. MasterFormat 95 SECTION 08480 MasterFormat 04 SECTION 08 42 36 EXTRUDED ALUMINUM TEMPERED GLASS BALANCED DOORS AND ENTRANCES PART I GENERAL 1.1 DESCRIPTION A. Work included: Entrance
More informationEX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.
25 YEARS OF EX C E L L E N C E ISO 9001 CERTIFIED COMPANY 3.0 INDEX ISO 9001 CERTIFIED COMPANY SECTION TOPIC PAGE 3.1 Double deflection linear bar grille ASLG 3 3.2 Double deflection linear bar register
More informationControl Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.
Insulated Control Dampers 2 Volume 1 - March 2010 6 Non-Insulated Control Dampers 8 Framing Accessories 9 Jack Shaft Steel Control Dampers Fire Dampers 10 11 Control Dampers and Fire Dampers 3900 Insulated
More informationTube Axial Inline Fans
Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the
More informationConstruct Compressed Air Building Near Bldg SECTION OVERHEAD COILING DOORS 07/07
SECTION 08 33 23 OVERHEAD COILING DOORS 07/07 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
More information