FSG-801. Fabricated Steel FEMA 361 Grille Chevron Blade. Application and Design. Standard Construction

Size: px
Start display at page:

Download "FSG-801. Fabricated Steel FEMA 361 Grille Chevron Blade. Application and Design. Standard Construction"

Transcription

1 FEMA 361 Grille Chevron Blade Application and Design is a severe duty fabricated steel grille designed to protect exterior wall penetrations on FEMA 320 or 361 compliant storm shelters or safe rooms. Most frequently is installed in front of wall louvers, but may be installed in front of any exterior wall penetration that requires protection. Design incorporates inverted V style blades which lend high free area and very little airflow resistance while providing maximum protection against extremely high wind loads and wind-borne debris. The is tested to FEMA , FEMA and ICC standards for storm shelters and safe rooms for debris impact only, which simulates a 15 lb. 2 x 4 traveling at 100 MPH. Model is a wind-storm rated assembly allowing the design professional to select and apply with confidence. Shown as head & sill mount configuration Standard Construction Mounting......Cantilever style Frame in. x 0.25 in. hot rolled steel, frame flanges located at top and bottom or sides Single section assembly customer specify flange configuration Multiple section wide assembly flanges located at top and bottom only Multiple section high assembly flanges located at sides only Blades Inverted V Style, 0.25 in. hot rolled steel Construction... Welded Screen ½ in. x 18 gauge expanded stainless steel Finish Powder paint, 24 standard colors available, (1 yr. finish warranty) Minimum Size..12 in. W x 12 in. H Maximum Single Section Size in. W x 76 in. H or 76 in. W x 120 in. H Shown as jamb mount configuration Maximum Overall Width Unlimited, may only be 1 section high Maximum Overall Height Unlimited, may only be 1 section wide Approx. wt lbs./sq. ft. (removeable lifting lugs provided) Options (at additional cost) Flush/recessed mounting configuration Deep sleeve *Width and height dimensions furnished actual size. Actual size does not include top and bottom flanges or side flanges.

2 PERFORMANCE DATA Free Area Chart (Sq. ft.) Louver Height Inches Airflow Resistance (Standard Air lb/ft 3 ) Louver Width Inches Model resistance to airflow (pressure drop) varies depending on louver application (air intake or air exhaust). Free area velocities (shown) are higher than average velocity through the overall louver size.

3 INSTALLATION DETAILS JAMB MOUNT Maximum Size and Installation Information Maximum single section size for model is 96 in. W x 76 in. H or 76 in W x 120 in H when applying the jamb mount configuration. Larger opening sizes may be constructed of multiple panels high. When installed in accordance with the methods shown within the attached submittal data sheets model will withstand wind-loads up to 248 PSF and is tested to FEMA , FEMA and ICC standards for storm shelters and safe rooms for debris impact only.

4 PRODUCT DETAILS JAMB MOUNT Anchor/Fastener Requirements-Jamb Mount Substrate Type Anchor/ Fastener Type Min. Edge Distance Min. Embedment Concrete (min psi) 1/2 in. Red Head SS LDT 3.25 in. 2.5 in. CMU (grout-filled, min psi) 1/2 in. Red Head SS LDT 3.25 in. 2.5 in. Steel (min. Fy 65,000 psi) 1/2 in. SS Bolt (tap or nut) 1.00 in in. Anchors or fasteners into building substrate are not supplied by Greenheck. Anchors or fasteners into building substrate are to be located on 12 in. centers or 9 in. centers if panels width exceeds 84 in.

5 INSTALLATION DETAILS HEAD & SILL MOUNT Maximum Size and Installation Information Maximum single section size for model is 96 in W x 76 in. H or 76 in W x 120 in H when applying the head and sill mount configuration. Larger opening sizes may be constructed of multiple panels wide. When installed in accordance with the methods shown within the attached submittal data sheets model will withstand wind-loads up to 248 PSF and is tested to FEMA , FEMA and ICC standards for storm shelters and safe rooms for debris impact only.

6 PRODUCT DETAILS HEAD & SILL MOUNT Anchor/Fastener Requirements-Head & Sill Mount Substrate Type Concrete (min psi) CMU (grout-filled, min psi) Anchor/ Fastener Type 3/4 in. SS Thread Rod in Red Head C6 Epoxy 3/4 in. SS Thru Bolt & Plate Washer Min. Edge Distance Min. Embedment 3.25 in in in. All Steel (min. Fy 65,000 psi) 1/2 in. SS Bolt (tap or nut) 1.00 in in. Anchors or fasteners into building substrate are not supplied by Greenheck. Anchors or fasteners into building substrate are to be located on 24 in. centers or 18 in. centers if both width is greater than 60 in. AND height is greater than 76 in.

7 OPTIONAL FLUSH/RECESSED MOUNT Size Restrictions and Installation Details Greenheck can also offer the grille in a recessed/flush mounting configuration should the standard cantilever style mount configuration not be suitable. The size restrictions and/or installation details referenced herein that pertain to the cantilever mounting configuration(s) are applicable for the recessed/flush mounting configuration. If desired, Greenheck can also factory install nearly any Greenheck louver model within the flush/recessed mount optional deep sleeve. September 2017 Copyright 2017 Greenheck Fan Corporation Greenheck Fan Corporation reserves the right to make product changes without notice.

AFL-501. Aluminum FEMA 361 Louver Chevron Blade Application and Design

AFL-501. Aluminum FEMA 361 Louver Chevron Blade Application and Design FEMA 361 Louver Chevron Blade Application and Design is an aluminum louver designed to protect exterior wall penetrations on FEMA 361 or FEMA 320 compliant storm shelters or safe rooms. Design incorporates

More information

AFG501 ALUMINUM FEMA 361 LOUVER LOUVER TYPE RECOMMENDED SPECIFICATION

AFG501 ALUMINUM FEMA 361 LOUVER LOUVER TYPE RECOMMENDED SPECIFICATION LOUVER TYPE AFG501 ALUMINUM FEMA 361 LOUVER Visible Mullion Louver Type... AFG501 Blade Material... Extruded Aluminum, Alloy 6061-T6 Blade... 0.25 in. (6.35 mm) Frame Material... Formed Aluminum, Alloy

More information

VCD-23. Flange Options. Size Limitations

VCD-23. Flange Options. Size Limitations Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators

More information

MODEL OAL. Water Penetration. Water Penetration. Free Area OAL PERFORMANCE REGISTERS GRILLES &

MODEL OAL. Water Penetration. Water Penetration. Free Area OAL PERFORMANCE REGISTERS GRILLES & MODEL OAL The OAL series of etruded aluminum stationary louvers is manufactured for installation in eterior wall openings. They are designed to allow fresh air and ehaust air to flow into/out of the building

More information

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction. Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options Application The series is a general purpose control damper for applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. A wide range of electric

More information

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating Application Model is a multi-blade fire damper with 3V style blades. The has been qualified to 4000 fpm (20.3 m/s) and 10 in. wg (2.5 kpa) for dynamic closure in emergency fire situations. Model may be

More information

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation Application and Design The is a severe environment 316SS ultra low leakage control damper with rugged stainless steel airfoil blades designed to meet the highest standards established for commercial control

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in. R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options. Application and Design The Series is a ruggedly built low leakage control damper with thermally insulated blades. The is intended for application in medium pressure and velocity systems. This model also

More information

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178) R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken blade to eliminate the transfer of heat or cold penetration and reduced

More information

HCD-230 Industrial Control Damper

HCD-230 Industrial Control Damper Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

Louver Products Severe Duty, Stationary, Operable

Louver Products Severe Duty, Stationary, Operable Louver Products Severe Duty,, Operable November 2017 Louver Selection Guide In an effort to help located and select the louver you need, this catalog organizes the more than 100 standard Greenheck louver

More information

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I Application and Design Model is a combination fire smoke damper that is UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model s operational ratings

More information

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178) Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure

More information

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed Application The is a low leakage thermally insulated damper with extruded airfoil blades. features broken blade which minimized the transfer of thermal energy and reduce condensation. It s also IECC (International

More information

VCD-23. Low Leakage CONTROL DAMPER

VCD-23. Low Leakage CONTROL DAMPER Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators

More information

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options Application and Design The series is a general purpose, low leakage control damper intended for application in low pressure and velocity systems. atings Pressure: 2 in. wg (.5 kpa) - pressure differential.

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options. Model Application The is a low leakage high performance control damper with extruded aluminum airfoil blades. Blades are completely contained within the frame allowing the damper to be directly mounted

More information

Thermal Isolation. Break

Thermal Isolation. Break Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade will minimize the transfer of thermal energy and reduces condensation.it

More information

Model VCD-20 3V CONTROL DAMPER

Model VCD-20 3V CONTROL DAMPER R Application and Design The series is a ruggedly built general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium

More information

Air Louvers OFAL 300 SERIES

Air Louvers OFAL 300 SERIES Fresh / Exhaust Model : OFAL GI 359 Description: Stationary Louvers is designed to provide air intake and air exhaust openings in building exterior walls to protect against the direct ingress of rain.

More information

VCD-23 Low Leakage CONTROL DAMPER

VCD-23 Low Leakage CONTROL DAMPER Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric actuators are available.

More information

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations. Application Model is a leakage rated modulating smoke damper with 3V style blades. The has been qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operational closure in emergency smoke control

More information

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper. Application The WD200 series are electrically motorized backdraft dampers that open when energized and spring return close when deenergized. The WD200 series are for horizontal or vertical mounting. Primary

More information

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations. Application and Design The is a vertical style face and bypass low leakage damper. This model is intended for application in medium to high pressure and velocity systems. Smooth profile extruded aluminum

More information

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations Application and Design The series is an ultra low leakage damper with rugged steel airfoil blades designed to meet the highest standards established for commercial control dampers. The airfoil shape reduces

More information

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-43 Extruded Airfoil Blade Control Damper Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure

More information

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure: Application and Design is a low leakage damper with vertical blade orientation designed to meet the highest standards established for commercial control dampers. The is intended for application in medium

More information

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating R Model Application Model is a 304SS combination fire smoke damper with 3V style blades. The is qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa). This damper may be installed vertically (with blades

More information

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations. Application and Design The WD300 series dampers are designed to prevent reverse airflow in horizontal exhaust applications. The WD300 features a pressure sensitive blade design that opens and remains open

More information

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating. Application Model is a combination fire smoke damper with 3V style blades. This model is designed for operation and dynamic closure in emergency fire smoke situations. It is rated for airflow and leakage

More information

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations. Application Model is a leakage rated smoke damper with 3V style blades. The has been qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operational closure in emergency smoke control situations.

More information

ARROW INDUSTRIAL PRODUCTS

ARROW INDUSTRIAL PRODUCTS IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products

More information

TO BE USED FOR MAINTENANCE MICHIGAN DEPARTMENT OF TRANSPORTATION. 2 3/16" x 2 3/16" x 10 Ga. 12" 15.5" 1 1/2" x 1 1/2" x 12 Ga.

TO BE USED FOR MAINTENANCE MICHIGAN DEPARTMENT OF TRANSPORTATION. 2 3/16 x 2 3/16 x 10 Ga. 12 15.5 1 1/2 x 1 1/2 x 12 Ga. 2 3/16" x 2 3/16" x 10 Ga. TOP VIEW 18" 1" 7/16" Hole 1 1/2" x 1 1/2" x 12 Ga. two sides only steel tubing 1 1/2" x 1 1/2" x 12 Ga. @ 18" long steel angle 15.5" 12" TRAFFIC 3/8" Hex head grade 5 steel

More information

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options. Application and Design The series is a vertical blade general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium

More information

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations. Model Application The is a leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper

More information

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model FSD-212. Combination FIRE SMOKE DAMPERS R APPLICATION Model is a combination fire smoke damper with 3V style blades. The has been qualified to 2000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operation and dynamic closure in emergency fire smoke

More information

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating R APPLICATION Model FSD-211 is a combination fire smoke damper with 3V style blades. The FSD-211 has been qualified to 2000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operation and dynamic closure in emergency

More information

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional. Application Model FD-50 is a static rated fire damper approved for use in walls and partitions with fire resistance ratings of hours or more. This model carries a hour UL fire damper label. UL555 classifies

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 474916 HBS Series Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or

More information

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features Model Application The is a leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper and smoke

More information

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features Application Model is a high performance combination fire smoke damper with Class I leakage. High strength airfoil blades ensure the lowest resistance to airflow in HVAC systems with velocities to 4000

More information

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS 14 15 STATIONARY LOUVER STATIONARY LOUVER SSL - 100 SSL SERIES SSL SERIES [SSL - 100, SSL - 110, SSL - 120] Air Performance Pressure Drop SSL - 100 Stationary Louver is a weather louver

More information

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options Application and Design The combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that both measures and regulates airflow volumes

More information

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-33 Air Measuring Station with VCD-33 Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CUSTOMIZED PANEL OPTIONS

CUSTOMIZED PANEL OPTIONS Four-Fold Doors CUSTOMIZED PANEL OPTIONS Four-Fold doors can be customized to match any building design! Choose from vision lites, grilles, decorative paneling, pass door and wood/composite cladding. HURRICANE

More information

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-331 Combination Fire Smoke Dampers R APPLICATION Model is a high performance combination fire smoke damper with class I leakage. High strength airfoil blades ensure the lowest resistance to airflow in HVAC systems with velocities to 4000

More information

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty Submittal Data Model PELV-100 Penthouse Elevator Vented Hood Application and Design The PELV-100 Penthouse Elevator Vented Hood is a gravity ventilator penthouse with an 18" x 18" gasketed access door

More information

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade

More information

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

Fusible Link (replaceable) Horizontal Mount

Fusible Link (replaceable) Horizontal Mount Application Model SSFD-50 is a static rated fire damper approved for use in walls and partitions with fire resistance ratings less than hours. This model carries a 2 hour UL fire damper label. UL555 classifies

More information

HVAC Control & Balancing Dampers

HVAC Control & Balancing Dampers HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* 1June 2017 Design and Construction Features Bearing Shaft Extension Jamb Seal Commercial Control Dampers

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Sidewall Propeller Fans Direct Drive. Exhaust / Supply Sidewall Propeller Fans Direct Drive / February 2009 Sidewall Propeller Fans Greenheck s sidewall propeller fan line is the ideal choice for factory and warehouse applications where high volumes of air

More information

Air Measuring Products AMD AMS IAQ

Air Measuring Products AMD AMS IAQ Air Measuring Products AMD AMS IAQ January 1 2012 Air Measuring Products Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. By measuring the

More information

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features Application Model is approved for use in walls, floors, and partitions with fire resistance ratings less than 3 hours. This model carries a 1 1 2 hour UL fire damper label. UL555 classifies dynamic rated

More information

Ford Fabricated Steel Products

Ford Fabricated Steel Products Ford Fabricated Steel Products Section N2 12/2000 The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 219/563-3171 FAX: 1-800-826-3487 Overseas

More information

SECTION DUCTWORK ACCESSORIES

SECTION DUCTWORK ACCESSORIES SECTION 15910 DUCTWORK ACCESSORIES PART 1- GENERAL SCOPE This sections includes accessories used in the installation of duct systems. Included are the following topics: PART 1- GENERAL Related Work Reference

More information

HVAC Control & Balancing Dampers

HVAC Control & Balancing Dampers HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* August 1 2013 HVAC Control and Balancing Dampers Commercial Control Dampers are used in buildings to regulate

More information

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features Application Model is approved for use in walls, floors, and partitions with fire resistance ratings less than 3 hours. This model carries a 1 1 2 hour UL fire damper label. UL555 classifies dynamic rated

More information

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features Application Model is approved for use in walls, floors, and partitions with fire resistance ratings of hours or more. This model carries a hour UL fire damper label. UL 555 classifies dynamic rated fire

More information

WALL MOUNTING KIT ASSEMBLY INSTRUCTIONS MODELS: TXBW & TXDW

WALL MOUNTING KIT ASSEMBLY INSTRUCTIONS MODELS: TXBW & TXDW Wall Opening Wall Mounting Adaptor (Optional) Support Strap E WALL MOUNTING KIT ASSEMBLY INSTRUTIONS MODELS: TXBW & TXDW The centrifugal power roof ventilators model TXB (belt drive) and TXD (direct drive)

More information

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems Medium Pressure Axial Fans Model TBI-FS Levels 3, 4 & 5 with Fabricated Steel Propeller Belt Drive Inline or Roof Mounted Upblast Clean Air or Fume Exhaust High Temperature Process Exhaust Emergency Smoke

More information

FILTERED AIR SUPPLY FANS

FILTERED AIR SUPPLY FANS BULLETIN 664-B September 2004 FILTERED AIR SUPPLY FANS Wall Mounted Roof Mounted Catalog Numbering System To identify a specific fan for ordering or engineering specification, it is necessary to show

More information

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation

More information

Climas y Proyectos Leyco, S.A. de C.V.

Climas y Proyectos Leyco, S.A. de C.V. GENERAL DESCRIPTION : FURNISH AND INSTALL MULTI COMPONENT ROOF MOUNTED LEYCO, MODEL CAH CUSTOM AIR HANDLER MADE SELF-CONTAINED, WEATHER RESISTANT, AIR HANDLING UNITS PER MODEL NUMBER, AND PERFORMANCE DATA

More information

GRAVITY VENTILATORS SIZING

GRAVITY VENTILATORS SIZING GRAVITY VENTILATORS SIZING RCXII (sizes 6-20) RCXII (sizes 24-36) RCXII-SF BGH RLX Sizing The tables shown offer quick selections at common static pressure points. Selection choices vary widely due to

More information

2. Backward inclined / backward curved centrifugal wheel fans. 3. Axial / backward curved mixed flow impeller bifurcated fans.

2. Backward inclined / backward curved centrifugal wheel fans. 3. Axial / backward curved mixed flow impeller bifurcated fans. SECTION 23 34 43 LABORATORY HIGH PLUME EXHAUST FANS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Motorized Fire Dampers

Motorized Fire Dampers Model : OMFD-611 (Fusible link and spring return actuator) GI steel sheet construction In accordance with UL555 & UL555S suitable for installation in walls and partitions having rating 2 Hrs. Static and

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4050 November 2009 DOWNBLAST ROOF EXHAUSTERS TYPE DCRD / BCRD (Spun Aluminum Housing) TYPE BCRD-E (Endurex Polymeric Housing) Downblast Roof Exhausters Twin City Fan & Blower

More information

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options Application Thermal Dispersion Air Measuring Station with VCD-23 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage control

More information

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options Application and Design Thermal Dispersion Air Measuring Station with VCD-42 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage

More information

StarFlex series 5000 Double-Ball Flexible Expansion Joint for the Protection of Water Wastewater, and Industrial Pipelines

StarFlex series 5000 Double-Ball Flexible Expansion Joint for the Protection of Water Wastewater, and Industrial Pipelines Joint Restraint Products StarFlex series 5000 Double-Ball Flexible Expansion Joint for the Protection of Water Wastewater, and Industrial Pipelines INFORMATION StarFlex Flexible Expansion Joints can deflect

More information

Blast Protection Damper

Blast Protection Damper Protection Damper plate shown as transparent height width 250mm wide 6.35mm thick blast plate bolted to damper frame 178mm 250mm standard depth 76mm standard flange Application The damper is designed for

More information

Outside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL

Outside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL OHCL Outside Horizontal Closable Louvers - mm Curved Profile 226-228F OHCL 124 Outside Horizontal Closable Louvers

More information

Fusible Link (replaceable) Horizontal Mount

Fusible Link (replaceable) Horizontal Mount Application Model FD-50 is a static rated fire damper approved for use in walls and partitions with fire resistance ratings less than hours. This model carries a /2 hour UL fire damper label. UL 555 classifies

More information

PC-125x Counter-Balanced Backdraft Damper

PC-125x Counter-Balanced Backdraft Damper PC-15x Counter-Balanced Backdraft Damper Product Bulletin Code No. LIT-101180 Issued April 7, 015 Refer to the QuickLIT Web site for the most up-to-date version of this document. Since 1885, Johnson Controls

More information

Installation, Operation, and Maintenance Instructions

Installation, Operation, and Maintenance Instructions Document Number 463384 VCD, FBH & FBV MODELS Vertical and Horizontal Mount Installation, Operation, and Maintenance Instructions This manual is the property of the owner, and is required for future maintenance.

More information

Premium Correctional Air Distribution. The First Name in Air Diffusion.

Premium Correctional Air Distribution. The First Name in Air Diffusion. Premium Correctional Air Distribution The First Name in Air Diffusion www.anemostat.com PRODUCT DIRECTORY APPLICATIONS Stainless Steel S-Vent MAXIMUM SECURITY GRILLES NEW CONSTRUCTION page 16 page 4 &

More information

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7 CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS 834.1 DESCRIPTION: This item shall consist of fire hydrant installations using joint restraints in accordance

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS 834.1 DESCRIPTION: This item shall consist of fire hydrant installations using joint restraints in accordance

More information

Steel Fabricated Coupling

Steel Fabricated Coupling Steel Fabricated Coupling Straight Connection IMPORTANT LINKS Click appropriate words to go to: Standard Limited Warranty Sales Terms & Conditions Freight Policy Returns Policy Corrosion & Product Selection

More information

S i o u x S t e e l G r a i n s y s t e m s. C o m m e r c i a l. G r a i n S y s t e m s

S i o u x S t e e l G r a i n s y s t e m s. C o m m e r c i a l. G r a i n S y s t e m s S i o u x S t e e l G r a i n s y s t e m s C o m m e r c i a l G r a i n S y s t e m s Engineered Using The Latest Technology For Your Grain Storage Needs Our roof has reached new heights. High capacity

More information

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-

More information

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-14

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-14 COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY Convectors STEAM AND HOT WATER RADIATION CC-1 Sterling Convectors are engineered for both forced hot water and two-pipe steam heating system installation with

More information

Tube Axial Inline Fans

Tube Axial Inline Fans Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the

More information

AlumaView AV200. A. Section Metal Fabrications: Miscellaneous for steel supports.

AlumaView AV200. A. Section Metal Fabrications: Miscellaneous for steel supports. AlumaView AV200 PART 1 GENERAL 1.1 SECTION INCLUDES A. Commercial sectional doors. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Miscellaneous for steel supports. B. Section 08710 - Door

More information

When Time is Everything... We Manufacture in Days - Not Weeks!

When Time is Everything... We Manufacture in Days - Not Weeks! When Time is Everything... We Manufacture in Days - Not Weeks! DAMPERS ACCESS DOORS LOUVERS July 2014 Specializing In Products For The HVAC Industry 763-783-7173 fax: 763-785-6977 1-800-297-9360 Customer:

More information

RC/RR MODEL FLAP GATES GENERAL DESCRIPTION DESIGN CONSTRUCTION

RC/RR MODEL FLAP GATES GENERAL DESCRIPTION DESIGN CONSTRUCTION GENERAL DESCRIPTION The Orbinox model RC and RR Flap Gates are designed for discharge lines such as levees, sewer lines and drainage conduits. The flap stays closed preventing water back-flow, and it opens

More information

Installation Instructions

Installation Instructions Installation Instructions READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step as

More information

ARROW UNITED INDUSTRIES

ARROW UNITED INDUSTRIES IP-3R ARROW UNITED INDUSTRIES Building Tomorrow s Ventilation Today Heavy Duty Dampers Industrial, Power Plant & Commercial Applications ARROW UNITED INDUSTRIES has specialized in the design and manufacturing

More information

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Positive Seal Damper Blades with Vinyl Gaskets 2.5 SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS BACKDRAFT DAMPERS BLADE OPTION: SR: 0.016-0.020 roll formed aluminum with vinyl gasket - used with fan motors under 1 HP SE: 0.05 extruded aluminum with vinyl gasket - used with fan motors over 1 HP Positive

More information

Architectural Louvers

Architectural Louvers Architectural Louvers Introduction AWV is headquartered in Holland, Ohio and is part of the Mestek Architectural Group. In addition to AWV, Mestek s Architectural activities include Linel and a strategic

More information

TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System

TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System 1.01 Typical Installation Scope TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System Section 1- General Furnish labor, equipment, tools and material to install the PPB-300 Steel Piers as

More information

SD-1250 and SD-1600 Series Smoke Dampers

SD-1250 and SD-1600 Series Smoke Dampers SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke