ELECTRONIC HID BALLASTS
|
|
- Brook Clark
- 5 years ago
- Views:
Transcription
1 ELECTRONIC HID S CONTENTS How to Read a Table Ceramic Discharge Metal Halide Ballasts Dimensions and Wiring Diagrams Cross Reference Guide Specifications
2 HOW TO READ AN ELECTRONIC HID TABLE NUMBER OF LAMPS Indicates the number of lamps the ballast will operate. INPUT VOLTS Voltage required from a power supply for proper ballast operation. PRODUCT CODE Abbreviated product description can also be used for ordering. INPUT POWER Total power input to the ballast which includes lamp watts and ballast losses. MAX IGNITION PULSE Maximum voltage pulse provided by the ignitor to initiate an electrical discharge in a gas filled tube. FACTOR Ratio of the lamp s lumen output on the specified ballast to the lamp s lumen output when operated by a reference ballast. WIRING DIAGRAM References the wiring diagram to use. DIMENSIONS Specifies ballast overall length, width, and height. No. of Lamps Volts Product Number Product Code (Watts) Nominal Line Amps Max Ignition Pulse Ballast Fig Width Height Total Ballast Weight (lbs) Wiring Diagram 20 Watt CDM Lamp, ANSI Code C56 or M C56/20E/MV/BE C56/20E/MV/SE kv N kv E LAMP TYPE Indicates the type of lamp that the ballast will operate. PRODUCT NUMBER Use this number when placing an order. NOMINAL LINE AMPS Ballast s rated line current. Typically the middle of an acceptable range. FIGURE Representation of the ballast. TOTAL CASE WEIGHT Total weight of ballast to include case. POWER FACTOR Watts to volt amps ratio, which measures efficiency of a ballast s power usage. TOC
3 Ceramic Discharge Metal Halide No. of Lamps Volts Product Number Product Code (Watts) Nominal Line Amps Max Ignition Pulse Ballast Fig Width Height Total Ballast Weight (lbs) Wiring Diagram 20 Watt CDM Lamp, ANSI Code C56 or M C56/20E/MV/BE kv N C56/20E/MV/SE kv E Watt CDM Lamp, ANSI Code C30 or M C30/35E/MV/BE kv N C30/35E/MV/SE kv E Watt CDM Lamp, ANSI Code C43 or M43; C39 or M39; C98 or M C39/70E/MV/BE kv N C39/70E/MV/SE kv E Drawing # (L) Width (W) Height(H) Mounting (M) Mounting (M2) E " M E N " H N2 4.5" 4.5" 3.0".6" 2.00" 0.26" W L E M H W L N Wiring Diagram BLACK WHITE GREEN ORANGE BROWN LAMP -22 Halco Lighting Technologies halcolighting.com TOC 229
4 Cross Reference Guide HALCO ADVANCE UNIVERSAL/ MAGNETEK M02/50HX/4T/K 7A D M50MLTLC3M500K M050-7C-52-K M0/50HX/4T/K 7A59-00D M50MLTLC3M500K M C-5-K M4/000CWA/4T/K 7A P000MLTAC5M500K M000-7C-62-K M4/000CWA/5T/K 7A D P000ML5AC5M500K M000-8C-6-K M49/750CWA/4T/K 7A64F2-00D P750MLTAC5M500K M0750-7C-62-K M49/750CWA/5T/K 7A D P750ML5AC5M500K M0750-8C-62-K M3/350CWA/4T/K 7A D P350MLTAC4M500K M0350-7C-6E4-K M3/350CWA/5T/K 7A D P350ML5AC4M500K - M32/320CWA/4T/K 7A D P320MLTAC4O500K M0320-7C-6E4-K M32/320CWA/5T/K 7A D P320ML5AC4L500K - M35/400CWA/4T/K 7A D P400MLTAC4L500K M0400-7C-6E3-K M35/400CWA/5T/K - P400ML5AC4M500K - M38/250CWA/4T/K 7A D P250MLTAC4L500K M0250-7C-6-K M38/250CWA/5T/K - P250ML5AC4M500K - M50/25CWA/4T/K HOWARD M90/00HX/4T/K 7A D M00MLTLC3M500K M000-7C-52-K M98/70HX/4T/K 7A D M70MLTLC3M500K M0070-7C-5-K TOC 230 Halco Lighting Technologies halcolighting.com
5 Specifications SPECIFICATIONS Ballast shall be furnished with integral, color-coded leads. Ballast shall tolerate sustained variations of +/- 0% of supply voltage with no damage to the ballast. Ballast shall operate in the range of 50-60Hz input frequency. Ballast shall operate at a maximum of 6 feet remote mounting distance. Ballast shall be microprocessor controlled. Ballast shall have integrated thermal, transient and end-of-life protection. Ballast shall be thermally protected to shut off when operating temperatures reach unacceptable levels. Ballast shall have an Underwriters Laboratories certification for operation in the US and either an Underwriters Laboratories or Canadian Standards Association certification for operation in Canada. Ballast shall comply with EMI and RFI limits of the code of Federal Regulations, Title 47, Part 8C for Non-Consumer equipment. Ballast shall have a Lamp Current Crest of <.7. Ballast shall provide the lamp with a low frequency square wave form to minimize visible flicker and increase lamp life. Ballast shall be Sound Rated Class A. Ballast input current shall have a Total Harmonic Distortion of <5%. Ballast shall have a greater than 90%. Ballast shall have a lamp end-of-life detection and shut down circuit. Ballast shall not contain PCBs. Manufacturer shall provide written warranty against defects in material or workmanship for 3 years from date of manufacture. Halco Lighting Technologies halcolighting.com TOC 23
Input Current (Amps) Input Power (ANSI Watts)
ICN-2S28-T@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (ANSI Watts) Ballast MAX THD % Power MAX Lamp Current Crest F14T5 1 14 0/-18 0.14 17 1.07
More informationInput Power (Watts) (min/max)
IZT-4PSP32-G@120V Input Voltage 120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor
More informationInput Current (Amps) Input Power (ANSI Watts)
ICN-2S54-90C-T@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (ANSI Watts) Ballast MAX THD % Power MAX Lamp Current Crest F54T5/HO 1 54-20/-29 0.53
More informationInput Power (Watts) (min/max)
IZT-2S26-M5-BS@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor CFQ13W/G24Q 1
More informationInput Power (Watts) (min/max)
IZT3PSP32SC@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor F17T8 3 17 50/10
More informationInput Current (Amps) Input Power (ANSI Watts)
ICF-2S42-M2-BS@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (ANSI Watts) Ballast MAX THD % Power MAX Lamp Current Crest * CFQ26W/G24Q 2 26 0/-18
More informationInput Current (Amps) Input Power (ANSI Watts)
Electrical Specifications HCN4S5490C2LSG@347 Brand Name CENTIUM T5 Ballast Type Electronic Starting Method Programmed Start Lamp Connection Series/Parallel Input Voltage 347 Input Frequency 50/60 HZ Status
More informationInput Power (Watts) (min/max)
IZT-2T42-M5-BS@120 Lamp Type Num. of Lamps Rated Lamp Watts M Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor CFTR32W/GX24Q 2
More informationInput Power (Watts) (min/max)
IZT-128-D@120V Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor F14T5 1 14 50/10
More informationInput Power (Watts) (min/max)
IZT-4PSP32-G@120V Input Voltage 120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor
More informationICN2S40N35I Ele Ballast (2) F40T V
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ICN2S40N35I Ele Ballast (2) F40T12 120-277V Philips Advance Catalog Number Manufacturer Description Weight per unit Product
More informationInput Power (Watts) (min/max)
IZT-2S32-SC@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor F17T8 2 17 50/10
More informationELECTROMAGNETIC HID BALLASTS
ELECTROMGNETIC HID BLLSTS CONTENTS 234 235 239 242 245 246 247 249 How to Read a Table Pulse Start Metal Halide Ballasts Standard Metal Halide Ballasts High Pressure Sodium Ballasts Guide Guide Cross Reference
More informationRELB2S40N35I (2)F40T12 120V Ele BLST
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 RELB2S40N35I (2)F40T12 120V Ele BLST Philips Advance Catalog Number Manufacturer Description Weight per unit Product Category
More informationReduce Maintenance Costs *
Reduce Maintenance Costs * Philips Advance programmed start parallel Optanium ballasts for T8 lamps helps lower maintenance costs with independent lamp operation. Philips Advance Optanium high-efficiency
More informationELECTRONIC HID BALLASTS
Overview Just as electronic ballast technology enhanced fluorescent lighting systems, electronic HID ballasts bring significant performance improvements to HID lighting systems: Higher efficiency Greater
More informationInput Current (Amps) Input Power (ANSI Watts)
Electrical Specifications ICN4S5490C2LSG@120 Brand Name CENTIUM T5 Ballast Type Electronic Starting Method Programmed Start Lamp Connection Series/Parallel Input Voltage 120-277 Input Frequency 50/60 HZ
More informationHigh performance for high ceilings
High performance for high ceilings Philips Advance Optanium programmed start parallel ballasts for T5HO and T8 lamps offers improved efficiency-saving on both energy and maintenance costs. Our new addition
More informationOptanium. High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps DESIGN HIGHLIGHTS: APPLICATIONS:
Optanium High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps P R O D U C T O V E R V I E W : Advance expands a new family of Smart Solutions for T8 lighting systems Optanium.
More informationELECTRONIC HID BALLASTS
ELECTRONIC HID BALLASTS Precision. Perfect Light. Remote Transformers Linear Fluorescents Sign Ballasts Electronic HID LED Drivers Electronic HID Ballasts Electronic HID ballasts have been designed from
More informationTVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts
TVE Overview Eco-0TM TVETM 0% TVE () 02.9.04 The (Eco-0) TVE is a 0% fluorescent dimming ballast for applications using a 0-0V control. TVE ballasts are also designed to work seamlessly with 0-0V lighting
More informationVEL2S40SC35I 2 F34T12 277V Electronic Ballast
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEL2S40SC35I 2 F34T12 277V Electronic Ballast Philips Advance Catalog VEL2S40SC35I Manufacturer Philips Advance Description
More informationVEL2P75S35I 2-F96T12 277V Electronic Ballast
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEL2P75S35I 2-F96T12 277V Electronic Ballast Philips Advance Catalog Number VEL2P75S35I Manufacturer Philips Advance Description
More informationMasterColor CDM-R111 70W/830 10D 1CT
MasterColor CDM-R111 70W/830 10D 1CT Product family description Philips MasterColor CDM-R111 combines the trendy look of the 111mm aluminum reflector halogen lamps with the long life, high energy efficiency
More informationINTRODUCING THE NEW MINI INVERTERS BY READY-LITE
INTRODUCING THE NEW MINI INVERTERS BY READY-LITE RELIABILITY THROUGH TECHNOLOGY FOR ECONOMICAL, RELIABLE POWER IN AN EMERGENCY, DEPEND ON MINI INVERTERS LED technology in emergency lighting systems has
More informationELECTRONIC HID BALLASTS
ELECTRONIC HID BALLASTS Precision Power. Perfect Light. Ballasts, Drivers, Transformers & Lamps For All Lighting Applications Electronic HID Ballasts Hatch Electronic HID ballasts have been designed from
More informationCompact SE Overview. High-Performance Dimming. Ballast
Compact SE Overview CompactSE 01.10.10 For designs requiring the energy savings and aesthetic appeal of dimmed T4 compact fluorescent or T5 twin-tube lamps, Compact SE dimming ballasts are your solution.
More informationRELIABILITY THROUGH TECHNOLOGY
INTRODUCING THE NEW MINI INVERTERS BY LUMACELL RELIABILITY THROUGH TECHNOLOGY MAXIMIZE EFFICIENCY AND RELIABILITY WITH MINI INVERTER EMERGENCY POWER As LED technology increases the efficacy of emergency
More informationConstant wattage for high intensity discharge (HID) lamps
onstant wattage for high intensity discharge (HID) lamps Index page Introduction 143 onstant wattage control equipment 144 onstant wattage application 145 onstant wattage mercury vapour and metal halide
More informationUnderstanding Electronic UltraMax HID Ballasts
Understanding Electronic UltraMax HID Ballasts GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID, like electronic fluorescent systems that preceded it, significantly
More informationThe Power Behind Energy
CONTENTS HID ELECTRONIC BALLASTS Page 1 HID DIMMABLE ELECTRONIC BALLASTS Page 6 Copyright DNA UK LTD 11 HID ELECTRONIC BALLASTS Product Features Options of dimmable ballasts via 1-10V or IPM (Intelligent
More informationUnderstanding Electronic UltraMax HID Ballasts
Understanding Electronic UltraMax HID Ballasts GE offers a complete line of electronic ballasts for HID lighting systems. Electronic HID, like electronic fluorescent systems that preceded it, significantly
More informationGECAP24400V0 Capacitor For 400W MH BLST
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 GECAP24400V0 Capacitor For 400W MH BLST G.E. Lighting (blst) Catalog Number Manufacturer Description per unit Product
More informationCompact SE Overview. High-Performance Dimming. Ballast
allast Compact SE Overview CompactSE- 03.08.04 or designs requiring the energy savings and aesthetic appeal of dimmed T4 compact fluorescent or T5 twin-tube lamps, Compact SE dimming ballasts are your
More informationLighting The Way. Ballast Specification Guide
Lighting The Way To Energy Savings Ballast Specification Guide Ballast Specification Guide Welcome to the American Ballast family of products and services In six short years, American Ballast has built
More informationICN3P32SC35I 3-F32T8 120/277V Electronic Ballast
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ICN3P32SC35I 3-F32T8 120/277V Electronic Philips Advance Manufacturer Description Weight per unit Product Category Features
More informationUL AND CODE COMPLIANCE
BAL500 FLUORESCENT EMERGENCY BALLAST 500 Lumens APPLICATION The BAL500 fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures into emergency
More informationBallasts For High Intensity Discharge Lamps
Ballasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity
More informationBallasts For High Intensity Discharge Lamps
Ballasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity
More informationLucalox PSL. GE Lighting DATASHEET. Lucalox PSL Tubular Clear 230V 250W, 400W, 600W and 750W Lucalox PSL Tubular Clear 400V 600W and 750W
GE Lighting Lucalox PSL Lucalox PSL Tubular Clear 23V 25W, 4W, 6W and 75W Lucalox PSL Tubular Clear 4V 6W and 75W Superb performance and high reliability DATASHEET GE s advanced sodium resistant ceramic
More informationBallasts For High Intensity Discharge Lamps
Ballasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity
More informationLighting Tables for Existing/Base Equipment 4/15/2011
T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031
More informationBallast Selector Guide
Selector Guide T8 Lamp Input Volts Catalog Nbr Family Start Type Also Operates F25T8 F17T8 F40T8 F32T8ES F28T8 F32T8 & F32T8/U 1 2 3 F32T8 & F32T8/U F32T8 & F32T8/U F32T8 & F32T8/U B132IRH-A Std Electronic
More information3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps
3-Wire Control, 220/240 Volt T-8 Linear, rev hi-220-240-1b 1.10.02 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) HOT DIMMED HOT NEUTRAL Hi-lume Power Control Dimming Ballast Lamps DESCRIPTION Continuous,
More informationSV14 technical specifications
aluminum weld in underwater light SV14 T he Sea Vision SV14 weld in model for aluminum hulls can be installed in the transom or the hull, it utilizes a 150 watt HID metal halide lamp and 110-230 volt AC
More informationGC SERIES HORTICULTURAL LIGHTING SYSTEM
It s the RIGHT Choice GC SERIES HORTICULTURAL LIGHTING SYSTEM US ER MANU A L & I NS T R U C TI ONS GC-630NS Advanced Low Frequency Square Wave Technology 315W CMH Grow Lamps Included PACKAGE INCLUDES 2
More informationMMagneTek ELECI RONIC FLUORESCENT BALLAST R'!AiB Tria d ' loiiiiiitrlllll-..lhod Now'lodloologv. Univefsal Voltage.
ELECI RONIC FLUORESCENT BALLA MATRIX Lamp Type "R" educed "H" armonic (THO< 20%) Low Profile Oly Voltage Instant Start Standard can Programmed Rapid Instant Start Start AccuStartTM Univefsal Voltage Low
More informationLighting Tables for Existing/Base Equipment 4/15/2011
T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031
More information1,2,3... As easy as. Mark 10 Powerline. For Compact Fluorescent Lamps
s easy as 1,2,3... Mark 10 Powerline immable allasts Listed 704G Philips dvance Mark 10 Powerline immable allasts make converting your existing fixtures easy. For companies looking to make their fixed-output
More informationLucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 50W, 70W, 100W, 150W, 250W, 400W & 600W
GE Lighting Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear W, W, W, 1W, 2W, W & W DATA SHEE T Lucalox TM XO Elliptical Diffuse W, W, W, 1W, 2W & W Product information
More informationGEM400ML5AA45 400W MH Core & Coil Ballast Multi Volt
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 GEM400ML5AA45 400W MH Core & Coil Ballast Multi Volt G.E. Lighting (blst) Catalog Number Manufacturer Description per
More informationThe power behind today s lighting designs
The power behind today s lighting designs Electronic HID: Driving performance in specification Unlocking the performance potential Electronic high intensity discharge (ehid) lighting is becoming an increasingly
More informationFDBT S 32W120V DM Bal
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-794 ax: 936-560-4685 llenwatson@elliottelectric.com DT430S 3W0V DM al Catalog Number Manufacturer Description Weight per unit Product Category
More informationLess energy. Enhanced performances.
ehid ess energy. Enhanced performances. Experience significant energy savings and increased lumen output vs. halogen lamps with Electronic High Intensity Discharge (HID) ballasts from Universal ighting
More informationArcstream Double Ended
GE Lighting Arcstream Double Ended Metal Halide lamps 7W, 15W and 25W Product Information High brightness, high quality white and coloured light with good colour rendition, excellent colour consistency
More informationModel ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase
Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible
More informationGE Lighting DATA SHEET. Product information. Features. Applications
GE Lighting Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 5W, 7W, W, 15W, 25W, 4W & 6W Lucalox TM XO Elliptical Diffuse 5W, 7W, W, 15W, 25W & 4W DATA SHEET
More informationBAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination
BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination APPLICATION The BAL1400 fluorescent emergency ballast works in conjunction with the AC ballast to convert
More informationGC SERIES HORTICULTURAL LIGHTING SYSTEM
It s the RIGHT Choice 5008685 GC SERIES HORTICULTURAL LIGHTING SYSTEM US ER MANU A L & I NS T R U C TI ONS GC-1000 HPS/MH/CMH A dva n c e d U lt r a Hig h Frequency Technology Compatibe with 1000W DE HPS
More informationFL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC
PC BASIC, 4 28 W PC BASIC Product description CELMA Energy Efficiency Index A2 / A3 Nominal life-time up to 50,000 h (at max. ta with a failure rate max. 0.2 % per 1,000 h) Large temperature range (for
More informationThe New York University Concourse Project. New York City. Existing Electrical Conditions
The New York University Concourse Project New York City Technical Report TWO Existing Electrical Conditions Kevin Hsia Lighting/Electrical Option Advisor: Professor T. Dannerth November 4, 2008 Executive
More informationQUICKTRONIC ICE Universal Voltage Systems
QUICKTRONIC ICE Universal Voltage Systems Electrodeless Fluorescent Systems Lamp / Ballast Guide lamp: ICE 40W QT1x40ICE/UNV lamp: ICE 70W QT1x100ICE/UNV lamps: ICE 100W QT1x100ICE/UNV QT1x150ICE/UNV lamp:
More informationHIGH FREQUENCY ELECTRONIC BALLASTS
HIGH FREQUENCY S Introduction High efficiency, high frequency electronic ballasts offer enhanced lighting performance and energy savings. The Electric Research Institute estimates that lighting consumes
More informationCity of Ottawa Street Lighting. HID Shoebox Style Luminaire
TITLE: Engineering Specification RECOMMENDED: S. Edey NO: 1 REV: APPROVED: D. O Keefe. LLS0002 OF REV. DATE: 2010-01-07 9 4 City of Ottawa Street Lighting HID Shoebox Style Luminaire For City of Ottawa
More informationBALLAST SELECTOR GUIDE
BALLAST SELECTOR GUIDE Universal Lighting Technologies is a member of the Panasonic Group. T8 s F32T8 & F32T8/U 2 3 F32T8 & F32T8/U F32T8 & F32T8/U F32T8 & F32T8/U Volts Catalog Nbr Family 20 347 F32T8ES
More informationLUNERA BALLASTLED TECHNOLOGY AND POWER FACTOR
LUNERA BALLASTLED TECHNOLOGY AND POWER FACTOR Replacing metal halide lamps in magnetic ballast-driven fi xtures with the Lunera MH HID LED Gen 2, a LED plug-and-play replacement, causes the ballast to
More informationLighting Tables for New Equipment 7/16/2008
T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH 2' F17T8 1 18 200 9.00 --- --- 2 32 201 9.00 --- --- 3 48 202 15.00 --- --- 4 57 203 15.00 --- --- F17T8 with Reflectors 1
More informationLighting Tables for New Equipment 2/24/2015
T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00 --- --- 2 32 207 11.00 --- --- 3 48 208 18.00 --- --- 4 57 209 18.00 --- ---
More informationT5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps
T5 versus T8 Fluorescent Lamps The good, the bad, & the ugly about T8 and T5 lamps Association of Energy Engineers- Cleveland Chapter Tuesday, February 22, 2005 Presented by: Lewis S. Sternberg, LC Consultants
More informationTECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT
TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT 1.0 PURPOSE: 1. To charge the battery bank through Solar PV source and AC supply. 2. To invert and produce utility quality sine wave. 3. Inverters
More informationEcoSystem Multiple Control Input Ballasts
Eco Multiple Control s Eco s 1 06.25.10 Digital electronic dimming ballasts maximize the benefi ts of a lighting management system. Eco s offer 100% to 10% dimming; ideal for use where saving energy, increasing
More informationSSX-180ST. SolarMaxx 180 Illuminator Service Manual
SSX-180ST SolarMaxx 180 Illuminator Service Manual 6018 Bowdendale Avenue Jacksonville, FL 32216 Customer Service: 904 731-5869 FAX 904 733 0012 Toll Free 800-684-6404 (English) Page 1 of 12 TABLE OF CONTENTS
More information3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube
3-Wire Control, 120, 277 Volt, T4 Quad Tube and T4 Triple Tube rev hi-compact-1a 3.7.01 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) T4 - One Lamp 3.00 w (76mm) x 1.00 h (25mm) x4.90 l (124mm) T4 - Two
More informationEATON 9315 UPS 200 TO 300 KVA Specifications
EATON 9315 UPS 200 TO 300 KVA Specifications Input Voltage Range See table below Frequency Range (60Hz) 57-64 Hz (50Hz) 47-53 Hz Surge Protection Meets ANSI C62.41, Category A & B EN 50091-2 and EN50082-2
More informationHi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming
Hi-lume LED Overview Hi-lume LED 1 12.11.9 Hi-lume LED is a high-performance, constant current driver that provides energy-efficient dimming for LED lighting. With industry-leading full-range % to 1% dimming,
More informationELECTRONIC FLUORESCENT BALLASTS
ELECTRONIC FLUORESCENT ALLASTS Fluorescent allasts AmbiStar SmartMate Standard T5HO PureVOLT 1 Lighting s Atlas -11 ELECTRONIC FLUORESCENT ALLASTS Fluorescent allasts Fluorescent allasts - - High-efficiency
More informationOkSolar LED Outdoor Luminaires
OkSolar 488500 LED Outdoor Luminaires 1.0 PURPOSE The purpose of this specification is to provide the minimum performance requirements for the LED Outdoor Luminaire Fixture. This specification refers to
More informationLighting Tables for New Equipment 3/9/2016
T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts (Fixtures or lamps with integrated occupancy sensors may be eligible for an additional sensor rebate - see page 7) LENGTH DESCRIPTION
More informationLUNERA BALLASTLED TM TECHNOLOGY AND POWER FACTOR
LUNERA BALLASTLED TM TECHNOLOGY AND POWER FACTOR Replacing metal halide lamps in magnetic ballast-driven fi xtures with the Lunera Susan Lamp, a LED plug-and-play replacement, causes the ballast to have
More informationREDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.
REDI-LINE ELECTRIC GENERATORS USER'S GUIDE Rugged, Reliable, DC to AC Power Conversion KARAM A.L. www.alternatorstarter.com 1-888-515-2726 REDI-LINE ELECTRIC GENERATOR MODEL INPUT ACTUAL OUTPUT ACTUAL
More informationBallasts For High Intensity Discharge Lamps
allasts For High Intensity Discharge Lamps Universal Means Higher Expectations In High Intensity Discharge Universal Lighting Technologies ( Universal ) offers a wide array of ballasts for High Intensity
More informationL I G H T W A V UV Electronic Ballast E 2010
L I G H T W A V UV Electronic Ballast 2010 E LIGHTWAVE High Frequency Electronic Ballast Function of an UV ballast To provide the proper voltage and current such that a steady plasma can be established
More informationSPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks
Project Type Model # Remarks Description: Firehorse Emergency Ballast for use with or without AC ballast designed to add emergency lighting when main AC power is interrupted for minimum of 90 minutes at
More informationHSI-HX / HSI-THX SA HSI-THX 400W 4K E40 SLV PRODUCT OVERVIEW DATA TABLE. Optical data
Range Features HX family of metal halide lamps for use with a mercury ballast with soft ignitor HX family can also be operated on SHP control gear, resulting in both different output and colour temperature
More informationPhilips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies
Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies Bob Trate - CPMR Philips/Advance Ballasts April 20, 2010 Fluorescent Ballast Overview There are several generations and design
More informationLighting Tables for Existing/Base Equipment 1/1/2014
T12 Fluorescent Lamps and Fixtures LENGTH Lighting Tables for Existing/Base Equipment OF CODE WATTS LENGTH OF CODE WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO
More informationBAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination
BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination APPLICATION The BAL3000 fluorescent emergency ballast works in conjunction with an AC
More informationSpy pocket Jeepmeter ope rati ng instructions
Spy pocket Jeepmeter ope rati ng instructions picltd.com PIPELINE INSPECTION COMPANY welcome Thank you for purchasing the SPY Model PJM Pocket JeepMeter. Pipeline Inspection Company and our SPY brand of
More informationWARNINGS, CAUTIONS AND NOTES
Welcome Please read this manual thoroughly before installing and operating your new Power Bright Power Inverter. This manual contains information you need to obtain the performance required for your application.
More informationBallast Selector Guide
Selector Guide Universal Lighting Technologies is a member of the Panasonic Group. T8 s F32T8 & F32T8/U 1 2 3 4 F32T8 & F32T8/U F32T8 & F32T8/U F32T8 & F32T8/U F32T8 & F32T8/U Volts Catalog Nbr Family
More informationLamps CERAMIC METAL HALIDE
s CERAMIC METAL HALIDE CERA ARC EX / Outdoor CERA ARC PRO / Indoor Long up to 24000 hrs Low maintenance s need to be changed less often, therefore saving on maintenance costs, reducing waste, and lessening
More informationCompact designs, unlimited possibilities
Lighting Compact designs, unlimited possibilities Low frequency electronic HID ballasts such as the Philips Advance e-vision line constantly measure and adjust the wattage, optimizing delivery of the ceramic
More informationConstantColor CMH MR16 Ultra
GE Lighting ConstantColor CMH MR16 Ultra New Generation of Reflector Ceramic Metal Halide Lamps 35W DATA SHEET Product information GE s low watt CMH lamps have opened new possibilities for lighting design,
More informationConstantColor CMH Supermini Ultra
GE Lighting ConstantColor CMH Supermini Ultra New Generation of Single Ended Ceramic Metal Halide Lamps 35W DATA SHEET Product information GE s low watt CMH lamps have opened new possibilities for lighting
More informationELECTRONIC FLUORESCENT BALLASTS
ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Optanium mbistar SmartMate Standard T5HO PureVOLT 1 ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Fluorescent allasts - - Optanium High-efficiency electronic
More informationSSX-300ST SolarMaxx 300 Illuminator
SSX-300ST SolarMaxx 300 Illuminator Service Manual 6018 Bowdendale Avenue Jacksonville, FL 32216 Customer Service: 904 731 5869 FAX 904 733 0012 Toll Free 800 684 6404 (English) TABLE OF CONTENTS Page
More informationLighting Tables for New Equipment 1/1/2018
T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts - REBATES are 50% of fixture/lamp cost, up to maximum amounts shown below LAMP LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00
More informationLucalox Standard Tubular Clear Product Code * * 11678* LU150/100/ HO/T/E40 LU150 /100/40
GE Lighting Lucalox Standard High Pressure Sodium lamps Tubular Clear & Elliptical Diffuse 70W, 100W, 150W, 250W, 400W and 1000W DATA SHEET Product information From GE s invention of HPS lighting in 1965
More informationEnergy Solutions LED Accelerator Program
Energy Solutions LED Accelerator Program Product Qualification Statement I hereby certify that the LED lighting product (Product) listed below meets all applicable general and specific criteria for qualification
More informationLucalox Standard. GE Lighting. Product information. Applications areas
GE Lighting Lucalox Standard High Pressure Sodium lamps Tubular Clear & Elliptical Diffuse 70W, 100W, 150W, 250W, 400W and 1000W DATA SHEET Product information From GE s invention of HPS lighting in 1965
More information