Do not touch rotating parts! ZONA CENTRO. c/ Oltra, Madrid Tel Fax:
|
|
- Bertina Paul
- 5 years ago
- Views:
Transcription
1 ELECTRIC SUBMERSIBLE PUMPS FOR WASTE WATER Presentation: FG CHIPER This manual is composed as follows: - Generalities - Transport and storage - Description of the pump - Installation/Assembly - Start up - Maintenance and conservatio n - Faults: causes and solutions - Relative literature Warning on safety: Symbols in this manual - In the pump: General warning! Danger! Danger of physical harm! Do not touch rotating parts! Electrical Danger! Peligro eléctrico! Attention! CE conformity symbol! SEDE CENTRAL Crta Molins de Rei a Rubí, km Rubí (Barcelona) Tel: Fax: info@elias.es ZONA CENTRO c/ Oltra, Madrid Tel Fax: rgonzalez@elias.es ZONA SUR Tel Fax: jorge@elias.es Manual - ELECTRIC SUBMERSIBLE PUMPS FOR WASTE WATER Page: 1
2 1.- Generalities General safety instructions - Before using the equipment, carefully read through this manual, it is necessary for your understanding and correct use of the pump and assures maximum performance whilst considering the safety of the worker. - Use the pump only for the intended use and under controlled conditions. - Do not stay near rotating parts. - Clean the pump before their maintenance and inspection. - Observe local regulations when working with harsh chemicals, corrosive, toxic, flammable and explosive. - Never remove safety symbols, keep them clean. - Always connect the ground. - The electric part of the pump should be handled with the pump stopped and WITHOUT TENSION, the terminals box should be closed. - Use a proper handle to lift and handle the pump. - Do not leave excess cable in the well (the pump may be damaged). - Avoid leaving the top of the cable in the water as it could go inside the engine, causing a fault Environment The main intention was to produce a product for ecological applications. In addition, the use of notoxic lubricating oil to help prevent environmental pollution. The parts that are replaced during repair, maintenance or renewal, may contain materials harmful to the environment. That's why we ask careful when disposing of these parts. Follow local environmental regulations in this regard. The electric pumps can not be used for fuel or other chemicals and explosives (except equipment ATEX) Safety Standards A. Operators who work in pumping stations of wastewater should be alert to the risk of diseases in the handling wounds. To avoid them, wear shoes, appropriate clothing, gloves, goggles and a gas mask if necessary. B. It is advised not to work a single operator. C. Mark the work area, especially if there is traffic. D. Ensure that the well or pit has enough oxygen. E. Ensure the electrical disconnection of the pumps before handling. F. Check that there is no risk of explosion before doing any welding Tips for good installation The electrical equipment must be outside of the pit, protected from weather and possible leakage of gas from the pit. Manual - ELECTRIC SUBMERSIBLE PUMPS FOR WASTE WATER Page: 2
3 The dimensions of the pit (volume) should allow not exceed the number of starts per hour recommended for each pump. ELECTRICAL CONNECTION An electrical test performed by the technician before installing the pump, will verify that all are respected security measures, according to current standards. The electrical connection must be grounded installed according to the rules, and to provide a motor voltage to ±10% of the value of the plate. Perform calibration of protective relays whose value must be greater than the figure for the electric board of more than 5%. Once you put the engine running, check that the value of current (amps) does not exceed the figure of the plate. Not consent to the pump in pools and tubs of water, unless it is mounted a safety contactor. Request information from a qualified technician. Electrical connections must be protected from moisture. If there is the risk of flooding, the connections must be transferred to a protected area. If necessary extend the power cable, must be checked that it is of good quality and appropriate section in relation to length and engine power. The union should be done by competent personnel and material to ensure the perfect insulation between conductors, the tightness and impermeability in time. The single phase pump is equipped as standard with a built-in thermal protection to protect it from voltage surges and possible blockages. For three-phase version is the responsibility of the user. In the single-phase version is also incorporated condenser. In the case of unemployment due to overheating, the pump is put back up after a cooling time of 15 minutes (while eliminating the causes of overheating), only single-phase model. 2. TECHNICAL INFORMATION 2.1 General The submersible pumps are designed primarily for pumping sewage. Construction details: - High efficiency motor, insulation class F (up to 155 º C). - Two independent mechanical seals in oil bath, forming an effective barrier between the pump and motor (depending on model). See product catalog, other models mechanical seal and lip seal. - Greased bearings for heavy duty long life. Manual - ELECTRIC SUBMERSIBLE PUMPS FOR WASTE WATER Page: 3
4 3. START After unpacking the pump and before installation, perform the following checkpoints: 1. Checki ng delivery: Check for any possible damage in transport, especially if the cable has been cut or damaged. Check the delivery of the entire pack. In the case of an incomplete delivery or damaged, please contact us immediately. 2. Oil Level: Check the oil level as indicated below. (Depending on model) 3. Power supply: Before making the electrical connections, check that the voltage and frequency correspond to the data line of the plate. Connect the pump according to the wiring diagram starter. For examples of wiring diagrams and wire codes, see appendixes. 4. Thermal switches: If the pump is single phase is equipped with thermal switch. When the pump does not work, contacts are normally closed. 5. Cable entry: Verify that the entry of the cable is tight, especially when the pump has been stored for long periods of time. If necessary, tighten the entry. 6. Motor Protection: The pump must always be connected to the line through a suitable circuit breaker motor protection. If the pump is started directly on line (DOL), protection circuit breakers must correspond to the current nameplate of the pump. For star-delta starter is a good practice to install an overcurrent relay directly after the main contactor. In this case, the pump is also adequately protected-star connection. The maximum setting of overcurrent is 0.6 x the current given on the plate. 7. Checking the engine: If there is any doubt about the condition of the motor or cable, you should test Megger motor winding against the cable outlet. The phase to ground resistance should be at least 1 Mohm. Turn the impeller by hand clockwise by means of a key "T" appropriate and do not use excessive force (Fig. 1). If necessary, remove the outlet elbow. With this process, you release the cemented surfaces of mechanical seals. 8. Pieces of the installation: Make sure all parts have been delivered. See also Chapter Control the direction of rotation: In the single-phase models is not necessary control the direction of rotation. In the three-phase version before starting the pump, check the rotation acting with maximum safety in the following way: Start the pump by observing the amount of water supplied. Stop it, and reversing each of the two phase conductors. Run it another time and compare the new capacity of water compared to the preceding observation. The correct direction of rotation corresponds to the increased capacity provided by the operation. We do not recommend turning the pump in reverse for longer than 3 minutes. Be careful! The recoil may be strong! (Fig. 2). Stay away from rotating parts! 10. Verification of current: Note the max current on the plate. Apply an ammeter to one of the phases during normal operation. Verify that the current is not higher than the value at the plate. If so, check: - Voltage (too low)? - Specific gravity or viscosity of the fluid (too high)? - Impeller clogged? - Direction of rotation correct? Manual - ELECTRIC SUBMERSIBLE PUMPS FOR WASTE WATER Page: 4
5 If the problem can't be solved, contact us. 11. Average Temperature / Load max. Engine: When the average temperature is higher than 40 C, reduce the maximum engine load. The classification between average temperature and maximum motor current draw is listed below. Compare the data on the plate with the ammeter reading data. If the motor current consumption exceeds the max. of table motor, the pump is not adequate or should reduce the consumption of the engine. Consumption can be reduced by installing a smaller impeller. In this case you have to ask us. Temperature ºC Current max. of motor % Starting frequency: When the pump is controlled by faders, ON and OFF levels should be adjusted so that the pump does not make more than 20 starts per hour. 13. Immersion depth min. and max.: The body of the motor must be submerged at least 2 / 3 for continuous operation at full load (Fig. 3) submerged pump. It is good practice. When possible, keep the engine body completely under water. Not applicable if the pump has a refrigeration system. The maximum immersion depth is 20 m. 4.INSTALLATION OPTIONS On submerged pumps, the following installations are available: V - Installation semisubmerged stationary with guides type V F - Installation semisubmerged, free fixing T - Installation transportable semisubmerged A - Submersible stationary Installation type V: Installation type V semisubmerged stationary. The pump is automatically coupled to the impulsion. Apart from the pump the following components are required: 1. Lower elbow, rubber joint and coupling adapter 2. A guide (not supplied) 3. Upper arm, 2 mounted inside the opening of the well 4. Level regulators to start, stop and alarm signals 5. Suspension level regulators and power cables 6. Pipe, valve, discharge elbows, etc.. Manual - ELECTRIC SUBMERSIBLE PUMPS FOR WASTE WATER Page: 5
6 Points to check before operation: - Both guides should be standing vertically (tolerance max. 3 º). - The installation angle should be about (Fig. 4). If necessary, this angle can be changed by altering the position of the lifting book on the suspension arm on top of the motor. - Adjusting the start and stop so that the engine achieves no more than 20 starts per hour. - Check that the engine is cooled properly. The average minimum is 2/3 of the motor body (Fig. 5). Fig. 4 Fig Installation type F Free collocation: semi-submerged and semi-permanent installation. The main accessories are: 1. Elbow hose connection or screw fixed to the pump. 2. Flexible hose or tubing. 3. Level regulators to start and stop, alarm signals. Points to check before operation: Fig. 6 - Adjusting the start and stop so that the engine achieves no more than 20 starts per hour. - Check that the engine is cooled properly. The average minimum is 2/3 of the motor body (Fig. 6) Installation type T Semisubmerged transportable installation without coupling: The main accessories are: 1. Elbow hose connection or screw fixed to the pump. 2. Flexible hose. Points to check before operation: fig. 7 - Do not let the pump from sinking into the mud. - Do not leave cable in the hole because it could be damage d by the pump. - Check that the engine is cooled properly. The average minimum is 2/3 of the motor body (Fig. 7). Manual - ELECTRIC SUBMERSIBLE PUMPS FOR WASTE WATER Page: 6
7 5. MAINTENANCE General Always disconnect the pump from the mains before inspecting or disassembling. Clean the pump (totally). The body of the motor could be hot right off the pump Projected maintenance (for mod. FLIP, FG, KV, FGT-600) After the first 20 hours of operation: - Check the oil level. - If more than a few drops of water in oil, contact us. Every 6 months or 500 hours of operation: - Check the oil level. - If more than a few cm ³ of water in oil, contact us. Change the oil every year or when it is not clear Lubricants - The bearings are greased for all life and they not require greasing again. - The oil chamber is filled with oil TELLUS 46 or equivalent. It is an organic oil to safeguard the environment but can also be mixed with mineral type of oil. Viscosity: cst. - The quantity of oil for the grinder pumps is 0.6 liters. The pump ELIAS, can be equipped with the automatic version with float switch (buoy). However, if necessary to lengthen or shorten the distance between the point of attachment of the float and the float itself, ensure that in the minimum water level the switch stops the pump. Attention! The distance between the gripper and the float point should not be less than 10 cm. OPERATION The pump must never run dry. Connect the plug into an outlet. The electric pumps with buoy are provided automatically as soon reached the maximum water level and stop when the level is minimal. MAINTENANCE AND REPAIR: Unplug the pump before starting any maintenance job. Should the electric pump work incorrectly it is necessary to exclusively address a specialised workshop, authorised to make repairs. To open and modify the electric pump is allowed only under authorisation of the manufacturer. Only original spare parts should be used. Manual - ELECTRIC SUBMERSIBLE PUMPS FOR WASTE WATER Page: 7
8 It should be remembered that we do not take any responsibility whatsoever for any damage to our electric pump if it has been opened and manipulated without our authorisation or that of an authorised workshop. The same goes for any non original spare parts that have been unduly assembled. The same conditions are valid for any eventual accessories supplied with the electric pump. Should the electric pump be used with liquids that leave deposits, it is recommended to effect frequent washing with clean water. To avoid eventual problems to the electric pump after long periods of use, we recommend a yearly control, always in a specialised workshop. The following parts should be controlled during maintenance: CONTROL Deterioration of the watertight joints Deterioration of the impeller Deterioration of O rings SOLUTION Substitute for new ones Substitute for a new one Substitute for new ones. Never use damaged O rings. FAULTS: CAUSES AND SOLUTIONS CAUSE SOLUTION The pump does not start up Control that it is plugged in and that there is tension on the Lack of tension line. Dismount the grid and verify that the impeller turns freely Blocked impeller without dismounting it Manually activate the float and check that it rises in a The float is not working normal way The pump turns but the amount of water supplied is almost nil or nil Low speed due to insufficient tension Stop the pump. Control the tension and the electric installation The water level is under the minimum of Stop the pump. Control the float on the automatic version the suction Blocked suction grid Clean the grid and eventually the hydraulic part Blocked discharge pipe Dismount the pipe and clean it The pump stops due to overheating and the consequent intervention of the motor thermal protection The electric supply does not conform to Unplug. The pump cannot be used on the existing the data on the motor plaque installation. Something solid has blocked the Control the hydraulic part hydraulic part If the pump has not been damaged, after 15 min. the The pump has operated dry. The pump pump will automatically start up. has worked with very hot water Eliminate whatever caused the overheating Manual - ELECTRIC SUBMERSIBLE PUMPS FOR WASTE WATER Page: 8
9 Departamento/Département/Department/Abteilung DECLARACIÓN C.E. DE CONFORMIDAD DÉCLARATIÓN C.E. DE CONFORMITÉ E.C. CONFORMITY DECLARATION E.G. KONFORMITÄTSERKLÄR UNG DIRECCIÓN TÉCNICA DIRECTION TECHNIQUE TECHNICAL MANAGEMENT TECHISCHE LEITUNG DECLARAMOS bajo nuestra única responsabilidad que el equipo de trabajo: NOUS DÉCLARONS sous notre unique responsabilité que l equipe de travail: WE DECLARE, under our sole responsibility, that the product: WIR ERKLÄREN hiermit unter Verantwortung, dass die produkt: Marca/Marque/Make/Marke Bomba Elias Tipo/Type/Type/Typ Sumergida Modelo/Modèle/Model/Modell C, CHIPER, FK, FG, FGt, FLIP Nº Serie/nº Série/Serial Nº/Seriennummer Año construcción/année de construction/year of manufacture/baujahr 2011 se adapta a las normas: /s adapte aux normes: / accords with the regulatión: /den folgenden Normen entspricht: ha sido construido y es conforme con los requisitos esenciales de las Directivas: elle a été construite en conformité avec les conditions essentielles des Directives: has been built in agreement with the essential requirements of the Directives: ist nach den wesentlichen Anforderungen der folgenden Richtlinien konstruiert worden: Directiva de referencia: Directiva de Máquinas 2006/42/CE Norma EN 809 (Seguridad de Máquinas) Directiva de Baja Tensión 2006/95/CE Directiva EMC 2004/108/CE (Compatibilidad electromagnética) Norma armonizada: EN Aplicada en particular EN Directive of reference: Machinery Directive 2006/42/CE Standard EN 809 (Machinery Safety) Low Voltage Directive 2006/95/CE Electromagnetic Compatibility EMC 2004/108/CE Harmonised standard: EN Applied in particular: EN Con exclusión de responsabilidades sobre las partes o componentes adicionados o montados por el cliente. Avec exclusion de responsabilités concernant les parties ou les groupes ajoutés ou montés par le client. With no liability for the parts or components added or assembled by the customer. Unter Haftungsausschlus für die vom Kunden beigestellten oder angebauten Teile order Baugruppen. El fabricante / Le fabricant / The manufacturer / Der Hersteller c.e. mar-11 Fabricado por BOMBA ELIAS Ctra. Molins de Rei a Rubí, km. 8, RUBI (BARCELONA) Teléfono: 34-(93) / Fax: info@elias.es / página web: Francisco Elias Administrador / Administrator Manual - ELECTRIC SUBMERSIBLE PUMPS FOR WASTE WATER Page: 9
VOLUMETRIC PUMPS. BOMBA ELIAS has developed the volumetric for clean water suitable for small flow rates and average height.
VOLUMETRIC PUMPS NIZA PISCIS Introduction: BOMBA ELIAS has developed the volumetric for clean water suitable for small flow rates and average height. NIZA series are technopolymers volumetric pumps, and
More informationDry installed pump type LANDY BTP.
OPERATION & MAINTENANCE MANUAL Dry installed pump type LANDY BTP. Landustrie Sneek BV Pieter Zeemanstraat 6 Tel. 0031 515-486888 P.O. BOX 199 Fax. 0031 515-412398 NL-8600 AD Sneek info@landustrie.nl The
More informationOperation & Maintenance Manual
Operation & Maintenance Manual Submersible pumps type LANDY DTP. Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199 info@landustrie.nl 8600 AD Sneek, Holland
More informationOperation & Maintenance Manual
Operation & Maintenance Manual Submersible pumps type LANDY DWP & Submersible pumps type LANDY DNP Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398
More informationRoboSterz. Automatic Management of Steering Without Operator ITA. Mod. V.
RoboSterz Automatic Management of Steering Without Operator ITA Mod. V. INDEX 1. What is it "RoboSterz"... 6 1.1. Benefits... 6 1.2. Installation... 6 2. Use of RoboSterz... 7 2.1. Use of the Robosterz
More informationOperation & Maintenance Manual
Operation & Maintenance Manual Submersible mixers type LANDY DWM & Submersible mixers type LANDY DNM Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199 info@landustrie.nl
More information& AL RC-SERIES GB HSC 09-W13 Edition 5. T +31 (0) F +31 (0)
OPERATION & MAINTENANCE ANCE MANUAL AL -SERIES 782-050-GB HSC 09-W13 Edition 5 Contents... page 1. FOREWORD... 4 2. GUARANTEE... 4 3. SAFETY AND ENVIRONMENT... 5 3.1 Symbols... 5 3.2 General safety instructions...
More informationOperation & Maintenance Manual
Operation & Maintenance Manual Submersible cutter pumps type DSP22 WETTERFRETTER 2.0 Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199
More informationUser Manual. PBA428 Weighing platform
User Manual PBA428 Weighing platform Service XXL Congratulations on choosing the quality and precision of METTLER TOLEDO. Proper use according to these instructions and regular calibration and maintenance
More informationDRAINAGE PUMPS Type RLV
DRAINAGE PUMPS Type RLV Owner s manual Identification Each pump has his code engraved on the nameplate. Type Serial V Pn-kW A Q l/1 O IP H mo µf RPM Hz kg Year fabriquant Type Code Serial Serial V nominal
More informationTPHK Series Immersible Pump
TPHK Series Immersible Pump Instruction Manual ISO 9001 Certified WALRUS PUMP CO., LTD. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No.83-14, Dapiantou, Sanzhi Dist., New
More informationTPHK Series Immersible Pump
TPHK Series Immersible Pump Instruction Manual ISO 9001 Certified Walrus America Inc 234867 EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No. 83-14, Dapiantou, Sanjhih Township,
More information& AL RW-SERIES GB HSC 08-W36 Edition 4. T +31 (0) F +31 (0)
OPERATION & MAINTENANCE ANCE MANUAL AL -SERIES 782-001-GB HSC 08-W36 Edition 4 Contents... page 1. FOREWORD... 4 2. GUARANTEE... 4 3. SAFETY AND ENVIRONMENT... 5 3.1 Symbols... 5 3.2 General safety instructions...
More informationOperation & Maintenance Manual
Operation & Maintenance Manual Submersible pumps type LANDY DTP Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199 info@landustrie.nl
More informationUser manual / 230 V. Electronically controlled motor, constant torque with intermediate reverse
User manual 16800-115 / 230 V Electronically controlled motor, constant torque with intermediate reverse TABLE OF CONTENTS Chap. Description Page 1 GENERALITY 1 2 Recommendations and percautions before
More informationDragone Pump DROPSA SpA In conformity with section 1.7.4, app. I, EEC Dir. 98/37/CE
INSTRUCTIONS FOR USE Dragone Pump DROPSA SpA In conformity with section 1.7.4, app. I, EEC Dir. 98/37/CE Company Name DROPSA SpA Address via Croce 1, 20090 Vimodrone (Mi), Italy Model DRAGONE pump Year
More informationInstruction Manual. * We reserve the right to amend specification without prior notice.
An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP INDRA HYDR TECH PUMPS PVT. LTD. 16, 1st Floor, th Cross, 4th Phase, Peenya Industrial Area, Bengaluru
More information77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product
77014 / 65041 Submersible Water Pumps Automatic Users Manual Carefully read this entire Instruction Manual before using this product Please read these operating instructions carefully and ensure they are
More informationInstruction Manual. Sewage lifting station compli 300
Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803
More informationPlunger Heads Use and Maintenance Manual
Plunger Heads Use and Maintenance Manual UK Positive displacement dosing pump Type PDP Series A-I 175 A-I 250 A-I 350 General instructions We thank you for choosing this product and recommend you read
More informationTPAK Series COOLANT PUMP
TPAK Series COOLANT PUMP Instruction Manual ISO 9001 Certified WALRUS PUMP CO., LTD. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No.83-14, Dapiantou, Sanzhi Dist., New Taipei
More informationY8USE - 09, 12, 18, 24-5R
Y8USE - 09, 12, 18, 24-5R by johnson controls Ref: E-IOM-W1104 GB Window unit Installation, Operating and Maintenance Instructions Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT
More information2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE
2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to
More informationSubmersible Effluent Pump
ME45 Submersible Effluent Pump INSTALLATION, OPERATION, & PARTS MANUAL SAFETY INFORMATION Carefully read and follow all safety instructions in this manual or on pump. This is the safety alert symbol. When
More informationHardware User s Manual
Hardware User s Manual. Behavioral chambers References: LE100-26 (76-0159) Version: V04/11/2014 Panlab, s.l.u C/Energía, 112 08940 Cornellà de Ll.(Barcelona) Spain www.panlab.com International Calls: +34
More informationInstruction Manual. * We reserve the right to amend specification without prior notice.
An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP Declaration of Conformity Company Name Indra Hydro Tech Pumps Pvt. Ltd. Address 16, 4th Phase, th Cross,
More informationBELT CONVEYOR CB/M5 Series
BELT CONVEYOR CB/M5 Series User and maintenance manual 1 DECLARATION OF CONFORMITY The company: Tel. +39-0444 450 620-451 520 Fax +39-0444 671 840 declares under its own responsibility that the machine
More informationDISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS
(Rev. 2.0_10-2010) DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS TRVK 2003 to 5003 TRSK 2005 to 5005 INTRODUCTION These instructions are for the maintenance staff in case of repair
More information1/2 HP SUMP PUMP OWNER'S MANUAL
TM 1/2 HP SUMP PUMP OWNER'S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
More informationBELT CONVEYOR PNL/4 Series User and maintenance manual
BELT CONVEYOR PNL/4 Series User and maintenance manual 1 DECLARATION OF CONFORMITY CE In conformity with the 2006/42/CE Machine Directives, Enclosure II, section A The company: VIRGINIO NASTRI S.r.l. Tel.
More informationSAUTER TVO Version /2014 GB
Sauter GmbH Tel.: +49-[0]7433-9933-199 Fax: +49-[0]7433-9933-149 Internet: www.sauter.eu Instruction Manual Motorized Vertical Test Stand SAUTER TVO Version 1.3 11/2014 GB PROFESSIONAL MEASURING TVO-BA-e-1413
More informationIP 900 W/KS & IP 900 D/KS
B W/KS & D/KS Installation and operating instructions We reserve the right to make modifications in the interest of technical development (4) 15975178 GB 04/05 1 pplication reas The submersible waste-water
More informationInstallation & Operating Manual
Installation & Operating Manual VN Series Non-Clog Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump 10/15 Edition Its Quality is unsurpassed in material and workmanship and has been
More informationUS - UP2/OIL 12V US - UP2/OIL 24V
SELF PRIMING ELECTRIC PUMP FOR TRANSFERRING LUBRICATING OILS OR VISCOUS FLUIDS INSTRUCTIONS FOR USE 164 220 12-US - UP2/OIL 12V 164 220 13-US - UP2/OIL 24V 15/05/14 Rev.02 A PRODUCT DESCRIPTION Self-priming
More informationINSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS AMP-22 MODEL
INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS This manual forms an integral part of the pump and must accompany it until its demolition. The series FMP peristaltic pump is a machine destined to work
More informationSARGON S - M - L. All rights reserved INSTALLATION MANUAL
INSTALLATION MANUAL Our compliments for your excellent choice. SARGON LINE S (300mm) M (400mm) and L (600mm) electro-mechanical gear motor has been produced for reliability and high quality. This Manual
More informationOWNERS MANUAL ECODIVER
OWNERS MANUAL ECODIVER ECO-DIVER Powerful multistage submersible pumps ideal for rain water systems, operating sprinklers, pumping water from tanks, cisterns, ponds and wells and other applications that
More informationSUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL
SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200
More informationSUBMERSIBLE WATER PUMPS
SUBMERSIBLE WATER PUMPS Model Nos. CS85S - CS85SA CS120S - CS120SA CS185S - CS185SA CS240S - CS240SA CS305S - CS305SA OPERATING & MAINTENANCE INSTRUCTIONS 1000 CONTENTS Warranty conditions... 3 Safety
More informationPump Manual. Model Numbers: SP240VDFS57LPM SP240VDFS80LPM. Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min
Pump Manual Model Numbers: SP240VDFS57LPM SP240VDFS80LPM Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min Copyright: Scintex Fuel Depot 2012[Type text] Page 1 WARNING:
More informationTriScroll TM 300 Series Dry Scroll Vacuum Pump
vacuum technologies TriScroll TM 300 Series Dry Scroll Vacuum Pump MODULE REPLACEMENT MANUAL idealvac.com Manual No. 699904285 Revision E May 2003 (505)872-0037 idealvac.com Varian TriScroll 300 Dry Scroll
More informationINSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70
INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70 This manual forms an integral part of the pump and must accompany it until its demolition. The series FMP peristaltic pump is a machine destined
More informationOperating and Maintenance Manual 6 to 8 rewound submersible motors
Operating and Maintenance Manual 6 to 8 rewound submersible motors Assembly and user manual Information about the manual... 3. Warnings and symbols... 3.2 Indications and accentuated text... 3 2 Safety...
More informationNo: Revision Operation & maintenance manual. BRAVO SLURRY PUMPS
No: 90 072 01 Revision 1 2005.07 Operation & maintenance manual SLURRY PUMPS www.grindex.com BRAVO Your choice of a submersible pump from Grindex has given you a pump that will serve you well for a long
More informationMod: KLD6-12/35XLAS-N
12/2011 Mod: KLD6-12/35XLAS-N Production code: 1914070 INSTRUCTION MANUAL LOGIC LINE PLUS HOOD Reseller Stamp for Warranty Dear customer, Above all, thank you for choosing our product and we would like
More informationSUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2
SUBMERSIBLE WATER PUMP Model Nos. CSE400A Part No. 7231100 0917 iss 2 OPERATING & MAINTENANCE INSTRUCTIONS Thank you for purchasing this Clarke Submersible Pump. This highly efficient pump is designed
More informationInstallation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps
Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps EI-700-008 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to Operation
More informationUnilift KP 150, KP 250, KP 350
GRUNDFOS INSTRUCTIONS Unilift KP 150, KP 250, KP 350 Installation and operating instructions DRAINAGE PUMP 1Z28 LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted
More informationOperating manual FP-2. Index
Operating manual FP-2 Index 1 Introduction... 2 2 Technical data... 2 3 Maintenance... 2 4 Directions of safety... 2 5 Starting... 3 6 Exhaustion... 4 7 Searching for an error... 4 8 Spare parts... 5 9
More informationGENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability
Diaphragm interposed fluid head Use and maintenance manual Model Model BR Model UK Positive displacement metering pump PDP Series Type B I 250 I 350 SD GENERAL WARNING General instructions We thank you
More informationc-go 24V/6A 24V/8A 24V/12A
c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...
More informationHeavy duty slurry pumps
USER S MANUAL Heavy duty slurry pumps TOYO PUMPS EUROPE Edition 27.07.2007 SAFETY INSTRUCTIONS TOYO PUMPS EUROPE User s manual for Toyo pumps type «GR..-2 3~10HP» This user s manual will help you to maintain
More informationOWNER S MANUAL SUBMERSIBLE UTILITY PUMP
Model 51101-0 OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475
More informationRental Industry Safety Tester Safe Check 5s
Rental Industry Safety Tester Safe Check 5s Feb 2006 2006 Clare Instruments Inc. Issue 2.0 Firmware Version : 1.2a Limited Warranty & Limitation of Liability Clare Instruments Inc, guarantees this product
More informationRescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference
Please dispose of Packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationFITTING AND CONNECTION INSTRUCTIONS
LEPUS is an oil-bathed motor-reducer created for sliding gates automation. The motor-reducer irreversibility allows a perfect and safe gate closing avoiding the setup of an electrolock and in case of power
More informationCrane fork KGM/KGA and KGQ/KGL
Crane fork KGM/KGA and KGQ/KGL Operating manual This equipment must not be installed, operated or maintained by any person who has not read and understood all the contents of this manual - 1 - Table of
More informationSDS Enclosed Star-Delta Starter User Guide
SDS Enclosed Star-Delta Starter User Guide (7.5kW~90kW) V2.0.0 PLEASE NOTE: AS STANDARD AND UNLESS OTHERWISE SPECIFIED, THIS PRODUCT IS EQUIPPED WITH A BASIC LOW INTEGRITY EMERGENCY STOP CIRCUIT STOPPING
More informationTBP SERIES PUMPS OPERATION & PARTS MANUAL
TBP SERIES PUMPS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements
More informationTension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!
Tension Meter FT Series S C H M I D T c o n t r o l i n s t r u m e n t s Edition FT 03.E Model FT Instruction Manual Valid as of: 01.09.2011 Please keep the manual for future reference! Contents 1 Warranty
More informationcause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.
Be sure to thoroughly read and understand the SAFETY PRES given in this section before using the equipment in order to operate the equipment correctly. The precautionary measures described in this section
More informationSUBMERSIBLE WATER PUMP
SUBMERSIBLE WATER PUMP MODEL NO: CSV1A, CSV2A PART NO: 7230582, 7230602 OPERATION & MAINTENANCE INSTRUCTIONS 0608 INTRODUCTION Thank you for purchasing this CLARKE Submersible Water Pump. This pump is
More informationELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010
ELECTRIC HOIST MODEL NO: CH2500B, CH4000B PART NO: 7630386, 7630391 OPERATION & MAINTENANCE INSTRUCTIONS LS1010 INTRODUCTION Thank you for purchasing this CLARKE Electric Hoist. Before attempting to use
More informationInstallation and Operating Instructions Electric Vibrators HV/VFL Series
Installation and Operating Instructions Electric Vibrators HV/VFL Series Original Instruction Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821 463081 Telefax +49 821 463084
More informationOperating Manual Includes Pumps: PG-9000 Part #R809606
Operating Manual Includes Pumps: PG-9000 Part #R809606 Introduction Thank you for selecting the PG Series Pumps from Lifegard Aquatics. Before using this pump please take a moment to review this manual.
More informationOperating instructions for PXFLOW sewage pumps
Operating instructions for PXFLOW sewage pumps Standard units PAPANTONATOS S.A. Roumelis & Kapetan Zacharia (ex. Afon Ntouna) 1 13677 Acharnes Attiki - Greece Tel: (+30) 210 2431111, FAX: (+30) 210 2431601
More informationOperating Instructions
Beuler Höhe 11, D-45525 Hattingen Tel. +49(0)2324/55515 info@stephandahlmann.de www.stephandahlmann.com Operating Instructions Contents Page 1. Designation and Illustration of the Machine 1 2. EC Declaration
More informationSUBMERSIBLE WATER PUMP
SUBMERSIBLE WATER PUMP MODEL No: IVP14A Part No: 7230095 OPERATION & MAINTENANCE INSTRUCTIONS 08/08 INTRODUCTION Thank you for purchasing this CLARKE water pump. This highly efficient centrifugal pump
More informationHardware User s Manual
Hardware User s Manual º Air puff control Treadmill TS References: LE8700TSAP 76-0920 Air-puff accessory for LE8700TS treadmill LE8708TSAP 76-0921 Air-puff accessory for LE8708 TS treadmill LE8706TSAP
More informationSUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514
SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514 INTRODUCTION Thank you for purchasing this CLARKE submersible pump. Before attempting to use the pump, please read this manual thoroughly
More informationSUBMERSIBLE DIRTY WATER PUMP
FOR USE WITH A 110V SUPPLY ONLY SUBMERSIBLE DIRTY WATER PUMP MODEL NO: DWP210A PART NO: 7230102 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Submersible
More informationThis manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding
Installation, Operating, Maintenance & Safety Instruction for M PUMPS CM MAG-M SERIES Centrifugal light Mag-Drive pumps (CM MAG-M06/1/2/3/4) This manual presents installation, servicing, troubleshooting,
More informationHydraPump Submersible Owner s Guide
HydraPump Submersible Owner s Guide USAGE GUIDE NOTE: This HydraPump has been designed to operate on 110-120 Volt, 60 Hz exclusively. Using any other voltage or Hz adversely affects performance. IMPORTANT:
More informationOPERATION & MAINTENANCE INSTRUCTIONS
400W SUBMERSIBLE PUMP WITH FOLDING BASE AND FLOAT SWITCH MODEL NO: PSV6A PART NO: 7230695 OPERATION & MAINTENANCE INSTRUCTIONS LS0315 INTRODUCTION Thank you for purchasing this CLARKE 400W Submersible
More informationTYPE 41LA MINING LED LUMINAIRE EXPLOSION PROOF LUMINAIRE WITH FLAMEPROOF PROTECTION (TYPE d)
Victor Products Ltd New York Way New York Industrial Park Newcastle upon Tyne NE27 0QF ENGLAND Tel : +44(0)191 2808000 Fax : +44(0)191 2808080 0518 Making Hazardous Environments Work TYPE 41LA MINING LED
More informationCH / H Series. Installation, Operation & Maintenance Manual. Project: Installation:
CH / H Series Installation, Operation & Maintenance Manual Project: Installation: Pump Model: Serial Number: HOMA Pump Technology, Inc. 390 Birmingham Boulevard Ansonia, CT 06401 GENERAL INSTRUCTIONS:
More informationW/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1
Pump Installation and Service Manual W/D/V-A1 Submersible Sump Pump W-A1 D-A1 V-A1 NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible
More informationPressure relief valve
Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0
More informationSUBMERSIBLE PUMP HSE RANGE
SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0806 SPECIFICATIONS Model No. HSE120* HSE200 HSE300*/ HSE360*/ HSEC400* HSE301 HSE361 Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2 50/2 50/2
More informationIM205 ITT. Wastewater. Vortex Series. Installation, Operation and Maintenance Instructions. Engineered for life
IM205 ITT Wastewater Vortex Series Installation, Operation and Maintenance Instructions Engineered for life 2 Vortex Installation, Operation and Maintenance Manual Table of Contents Table of Contents Introduction
More informationVADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY
PRODUCT OVERVIEW The VADA V75-S submersible pumps are suitable for installation in traditional wells, water deposits, collection tanks, clear watercourses, lakes etc. The V75-S provides a hydraulic system
More informationESE Series Cast Iron Sewage Pumps
Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................
More informationoriginal operating manual Operating manual Translation of the Item-No.: ,
Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty
More informationGARDEN HOSE UTILITY PUMP
GARDEN HOSE UTILITY PUMP MODEL #HPP360, HPP12V, 473707 MODEL #HPP360, 473707 MODEL #HPP12V ATTACH YOUR RECEIPT HERE Purchase Date SAFETY INFORMATION Please read and understand this entire manual before
More informationInstallation Manual for DC Injection Brake Units
Power Drive Services INJ Series DC brake modules PDS 11-30-100A Page 1 of 17 Issue 15 Contents. 1. Safety. 2. Installation. 3. Setting Up. 4. Wiring Diagrams. 5. Specifications. 6. Selection. 7. Timing
More informationSUBMERSIBLE WATER PUMP
SUBMERSIBLE WATER PUMP MODEL NO: CSV1A, CSV2A PART NO: 7230582, 7230602 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS 05/14 iss 4 INTRODUCTION Thank you for purchasing this CLARKE Submersible
More informationOpen Chassis Star-Delta Starter User Guide
Open Chassis Star-Delta Starter User Guide (7.5kW~90kW) V2.0.1 Contents 1 Safety information... 1 2 Technical Data... 2 3 Supply & Motor Connections & Circuit Diagrams... 5 4 Control Connections & Operation...
More informationHIB Enclosed Inverter User Guide
HIB Enclosed Inverter User Guide (0.75kW~22kW) V1.2.0 Contents 1 Safety information...1 2 Technical Data...2 3 Motor Connection...4 4 Operation...5 5 Single phase circuit diagram...7 6 Three phase circuit
More informationDIAPHRAGM PUMPS: Instruction Manual
INTRODUCTION DIAPHRAGM PUMPS: Instruction Manual Congratulations for choosing a product Imovilli Pompe, the result of a careful manufacturing process supported by over fifty years of specific experience
More informationQWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: 6.10.065 Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication.
More informationOperating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA
5.52.714.00.1.0 Edition 03.2004 GB Operating and Maintenance Manual for HADEF overhead crane as jointed crane TA Subject to changes. 1 HADEF Table of Contents 1 General Page 3 2 Product description Page
More informationInstallation and Operating Guidelines Battery Back-up Pump System
Installation and Operating Guidelines Battery Back-up Pump System www.tritonsystems.co.uk 1 Contents 1.0 Product Summary... 3 2.0 Installation Guidelines... 3 3.0 Technical Specification... 4 4.0 Dimensions...
More informationPro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationSUBMERSIBLE PUMP HSE RANGE
SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0707 SPECIFICATIONS HSE300* HSE360* Model No. HSE130* HSE200A HSE300A HSE360A HSEC400* HSE301A HSE361A Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2
More informationSubmersible Tank Pump
Submersible Tank Pump Applications: Silent household pressure systems, garden irrigation, or water transfer. Performance Outline Pump Features High efficiency moulded impellers Stainless steel construction,
More informationTB SERIES PUMPS TBS OPERATION & PARTS MANUAL
TB SERIES PUMPS TBS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements
More informationCompact System NRGS 11-2 NRGS Original Installation Instructions English
Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive
More informationOperating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7
EBL 208, Art.-No 911.430 Seite 1 / 7 Contents 1. Description 2. Safety Information 3. Operating Instructions 4. Transport, Storage, Installation 5. Electrical Installation 6. Power-Up, Shut-Down, Maintenance
More informationM Series Condensate Recovery Unit
0898050/3 IM-P089-29 ST Issue 3 M Series Condensate Recovery Unit Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Wiring diagram
More information.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.
Issued 2005/06/01 Section 15440 Plumbing Pumps Page 1 of 9 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3 Section 01780 Closeout
More information