Label Information: FPS75 FPS80 Cranking Warning Label
|
|
- Kenneth Boyd
- 5 years ago
- Views:
Transcription
1 FLAMEPROOF STARTER MOTOR FPS75 & FPS80 PRODUCT DATA SHEET: PDS ISSUE 4 DESCRIPTION FPS75 & FPS80 starter motors are suitable for Zone 1 hazardous areas where explosive gases occur (ATEX directive 94/9/EC). The units are supplied in a robust mild steel flameproof casing. The unit includes 3m of supply cable wired through Exd glands. The units have double pole wiring which is insulated from chassis. THIS EQUIPMENT MUST BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH BS EN AND 17. FAILURE TO OBSERVE ANY INSTRUCTIONS IN THIS DATA SHEET MAY INVALIDATE ANY WARRANTY AGREEMENT. TECHNICAL DATA Label Information: FPS75 FPS80 Cranking Warning Label Type of Protection Flameproof Standards of compliance EN : 2012 EN : 2007 Ambient Temperature Weight Nominal Power -20 o C to +45 o C 45kg 8.0kW (24V DC) Type No FPS75 FPS80 Part Numbers SAE Nose Housing Page1
2 INSTALLATION AND ELECTRICAL CONNECTIONS Installation should be carried out in accordance with EN or other national standards. Under no circumstances should the weight of the unit be supported by its cables. The unit is heavy (45kg), use appropriate lifting equipment. Shoulder Bolts (Ex Special) M10 for FPS75 5/8-11 UNC for FPS80 M6 Screws Fitting the Starter: The unit is fitted to the flywheel housing via the 3off shoulder bolts (M10 or 5/8-11 UNC, see above), however these are not accessible without removing the motor cover, so the following procedure should be followed: Loosen the cable glands and remove the M6 screws shown above. Slide the flameproof cover back while feeding the cable through the glands carefully. Lift the motor into place (sling and crane) and fix using the M10 or 5/8-11 UNC shoulder bolts provided. These bolts have controlled diameters that make a flameproof joint and must not be changed except for exact replacements. Pyroban does not make recommendations on starter mounting bolt torque, as the flywheel housing material may vary. Re-fit the cover taking care in feeding the cable through the glands. Re-fit the M6 screws and tighten to 12Nm Check the cover is secured fully with no flange gap by using a 0.15mm feeler gauge. Re-fit if the gauge penetrates the joint. Re-tighten the cable glands (hand tight + ½ turn). Fit the cranking warning label near the ignition key/button. Electrical Connection: The unit is provided with 3m leads. Where practical, the 35mm² power cables should be shortened to optimise cranking performance. These cables are marked + for positive and for negative and need to be connected to a suitable 24V battery supply. All the cables are to be terminated in a correctly rated enclosure with appropriate terminals. The 2 core cable only uses the brown (or no1) core as a trigger line and should be connected via a current limiting device protecting it to 26A. The blue (or no 2) line is unused and should be capped. Cables leading to the starter motor must be clamped to prevent twisting or pulling. Page2
3 Wiring Diagram: OPERATION The surface temperatures rely on limited operator cranking, hence the following instructions must be followed: If the engine fails to start within 30 seconds, release the start button/ignition switch. Wait for two minutes in order to allow the starter motor to cool before attempting to re-start. The starter motor should not be cranked more than 6 times per 30 minutes. INSPECTION AND MAINTENANCE Maintenance may not take place in a hazardous area. The starter contains no user serviceable parts. A record must be kept of all maintenance and repairs to BS EN monthly: Check for mechanical damage. Check the starter is mounted securely. Check the conditions of the leads, ensuring they are still fixed in position. Check gland tightness. Should the unit suffer impact or damage, the casing must be checked for permanent deformation. Should flameproof joints be damaged, the unit must be sent back to Pyroban for repair or replacement. Should the glands or blanking plug be damaged, they must be replaced with a suitable flameproof gland or blanking plug and the entry threads of the casing checked. A record must be kept of all maintenance and repairs to BS EN The minimum grade of the M6 cap screws in the motor casing, the M10 or 5/8-11 UNC shoulder screws and the M8 cap screws on the starter nose cone are all grade 12.9 should they need replacing. Page3
4 FPS75 DIMENSIONS FPS80 Page4
5 PERFORMANCE GRAPH (BOTH UNITS) Page5
6 REMOVAL FROM SERVICE AND DISPOSAL Using information provided in this data sheet advice should be obtained from the waste regulation authority whether special waste regulations apply. ORDERING SPARE PARTS Use only genuine Pyroban parts. Order spares or replacement parts directly from Pyroban quoting the Pyroban Part Number. Note that fitting of incorrect parts may invalidate certification. DECLARATION OF CONFORMITY We, Pyroban Limited, Dolphin Road, Shoreham-by Sea, Sussex, BN43 6QG, UK, declare that the component mentioned in this data sheet has been designed and manufactured in accordance with the essential heath and safety requirements of Directive 94/9/EC(ATEX) inclusive of subsequent amendments. Compliance with these Directives is established by meeting the technical requirements of the relevant CEN and CENELEC standards. Dario Bussandri Engineering Manager OTHER INFORMATION Nothing contained in this brochure is intended to extend any warranty or representation, expressed or implied, regarding the products described herein. Any such warranties or other terms and conditions of sale of products shall be in accordance with Pyroban s standard terms and conditions of sale for such products, which are available upon request. Specifications and machinery may be altered without notice at any time. CONTACTS Pyroban Limited Dolphin Road Shoreham-by-Sea W. Sussex BN43 6QG United Kingdom Telephone: +44 (0) info@pyroban.com Pyroban Benelux BV Grotenoord LT P.O. Box AE AEHendrik Ido Ambacht Nederland Telephone: +31 (0) info@pyroban.com Pyroban Suzhou Workshop B2 North Lou Zhong Lu Suzhou Industrial Park Suzhou Jiangsu Province P.R.China Telephone: +86(0) info@pyroban.com Page6
EVZ Series (Small body) Explosion protected luminaire Operating Instructions
EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East
More informationILED Aquarius Illuminated Windsock. User Manual
Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description...
More informationExplosion protected terminal boxes type, GHG 72.
1 Technical data 1.1 Plastic terminal boxes GHG 721... ATX type examination certificate BVS 13 ATX 013 X Marking acc. to 94/9/G and standard ATX x (d e mb) II T5* -55 T amb +55 Gb x (d e mb) II T6* -55
More informationOperating Instructions
Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety
More informationOperating Instructions
Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More information2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions
2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions 2562179B REV. B 818 Printed in USA 2013-2018 Federal Signal Corporation. All rights reserved. Limited Warranty
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical
More informationOperating Instructions
Operating Instructions Repair Light > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage and Disposal...6
More informationZone 1 Linear Range - Installation Guide
Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text
More informationILED Dorado. User Manual
10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...
More informationINSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS
INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS Address all communications and shipments to: FEDERAL SIGNAL CORPORATION Industrial Systems Group 2645 Federal
More informationProduct manual cable glands type IR and IB. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands
Product manual cable glands type IR and IB INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these instructions
More informationOperating Instructions
Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL
More informationVALIADIS S.A. HELLENIC MOTORS
Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe
More informationSafety Switches Series 8537
Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3
More informationEuromech 2G. Operator Manual TO BE HELD BY END USER
Euromech 2G Operator Manual TO BE HELD BY END USER Pyroban your partner in Explosion Protection Thank you for choosing Pyroban to explosion protect your materials handling equipment. We have been converting
More informationELECTRICALLY OPERATED TORQUE WRENCH (VC-RAD) USER GUIDE
ELECTRICALLY OPERATED TORQUE WRENCH (VC-RAD) USER GUIDE Ref: WCOI.055 Issue: 5 Date: June 2015 CONTENTS Page Description 1 Introduction 2 Training Requirements General Safety 3 Accessories Available VC-RAD
More informationRescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference
Please dispose of Packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationEx m Solenoid Operator Type 0519
nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for
More informationHEAVY DUTY PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE
HEAVY DUTY PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE Ref: WCOI.041 Date: June 2015 Issue: 4 Page Description CONTENTS 1 Introduction Training Requirements 2 General Safety 3 C-RAD Wrench Models Covered
More information10 Load and Motor Switchgear
10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,
More informationPNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE
PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE Ref: WCOI.031 Date: Mar 2017 Issue: 10 Page Description CONTENTS 1 Introduction Training Requirements 2 General Safety 3 C-RAD Wrench Models Covered By Manual
More informationIQL Helios Area-/Streetlight. User Manual
Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description... 5 5. Specifications... 6 5.1 General... 6 5.2 Dimensions... 6 6. Installation...
More informationSpecial Radial piston pumps Type SRK-ATEX
Special Radial piston pumps Type SRK-ATEX Features High volumetric efficiency Self-priming and venting Low pulsation Low noise level Design Radial piston pump of modular design With valve controlled pump
More informationEC MACHINE DIRECTIVE COMPLIANCE DECLARATION
EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the 770
More informationControl and Terminal Box Type A21-**-*****
e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de
More informationInstruction Manual. Q Series 2 Motor Control Modules - OEM
A382-21-880 Issue B Instruction Manual Q Series 2 Motor Control Modules - OEM Pump/ Q Motor Control Module Item Number pumping system Electrical supply 24 V d.c. control 24 V a.c. control QDP40 200-230
More informationFlameproof Alternator
Flameproof Alternator Installation, Operation and Maintenance Alternator Types ASX-400 ASX-401 CE242 (6) ASX_0210 DESCRIPTION Twelve pole rotating field coil type externally excited alternators designed
More informationApparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components
E X - D D I S T R I B U T I O N S with metal EJ enclosures for gases in explosion group IIB Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures.
More informationTANKERS OPERATING & SAFETY INSTRUCTIONS FOR SPARE PARTS GO TO
TANKERS OPERATING & SAFETY INSTRUCTIONS FOR SPARE PARTS GO TO WWW.MARSHALL-TRAILERS.CO.UK FOR MODELS: ST1200, ST1400, ST1600, ST1800, ST2000, ST2300, ST2550 CHARLES J. MARSHALL (ABERDEEN) LTD CHAPEL WORKS,
More informationTAKING SAFETY FURTHER
TAKING SAFETY FURTHER DIESEL ENGINES AND EQUIPMENT FOR HAZARDOUS AREAS CAT EXPLOSION PROTECTION SAFEGUARD BUSINESS AS USUAL INTRODUCING CAT EXPLOSION PROTECTION In 2011 Caterpillar Inc. acquired the Pyroban
More informationSynergEX Panelboards. Installation & Maintenance Information IF Panelboards for Hazardous Locations SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
SynergEX Panelboards Panelboards for Hazardous Locations Installation & Maintenance Information IF 1659 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CAUTION Read these operating instructions and all other
More informationHermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858
Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858 Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO
More informationSelf-Exciting Flameproof Alternator
Self-Exciting Flameproof Alternator Model ASX-310 Application l For use use in in hazardous hazardous areas areas classified classified as as Zone 1, For Zone 1, Gas Group IIB, T4 and Dust Group IIIC,
More informationEC MACHINE DIRECTIVE COMPLIANCE DECLARATION
770 EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the
More informationINSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS SOLAS LED Luminaire ATEX & IECEx
IOM SOLAS - ZONE 1 Luminaire (ATEX & IECEx) Issue 01 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS SOLAS LED Luminaire ATEX & IECEx Important: Please read these instructions carefully before installing
More informationSwitching DC Power Supply
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary
More informationROM Series. Established Leaders in Flow Control. Installation Manual. Valve Actuators
ROM Series Installation Manual Valve Actuators Established Leaders in Flow Control Contents Section Page Health and Safety 3 Storage 4 Mounting the actuator 4 Setting the actuator stop bolts 5 Cable connections
More informationInstruction Manual. Ex-Time 40 / 50
Instruction Manual Ex-Time 40 / 50 Contents 1. Introduction 13 2. Safety Advice 13 3. Faults and Damage 13-14 4. Safety Regulations 14 5. Ex-Data 14-15 6. Technical Data 15-16 7. Use and Application /
More informationPOWER CONNECTOR TERMINATION / HOOK UP PROCEDURE
Power POWER CONNECTOR TERMINATION / HOOK UP PROCEDURE (AI365 Rev 7 15Nov16) Hawke International UK Office, Oxford Street West, Ashton-under-Lyne, Lancashire. OL7 0NA. UK Sales: +44 (0) 161 830 6698 Technical:
More informationFloodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - D D S T R B U T O N S with metal EJ enclosures for gases in explosion group B Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures.
More informationSynergEX Panelboards for Hazardous Locations
SynergEX Panelboards for Hazardous Locations Installation & Maintenance Information 1. APPLICATION SynergEX panelboards provide short circuit protection for feeder or branch circuits to control lighting,
More informationCertificate of Incorporation (Typical)
Certificate of Incorporation (Typical) Declaration We Varley Pump Limited hereby declare that the following machinery has been designed to be safely incorporated into other machinery and must not be put
More informationFlameproof Alternator
Flameproof Alternator Models ASX-400, ASX-401 Application l For use in hazardous areas classified as Zone 1, Group IIB, T4 l Suitable for local ambient temperature range -30 C to +50 C l Designed as a
More informationInstallation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7
Please read these Installation and Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunction or to clutch failure, resulting in damage to other
More informationFigure 1 Figure 2 Double Acting Actuator Spring Return Actuator
ACCORD CONTROLS Aviator II Valve Controller Installation Operation Maintenance FCD ACENIOM0100-02 Mechanical Installation: Installation is best performed with the NAMUR mounting kits. These kits allow
More informationElmdene International Ltd
1 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44(0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk 13.8Vdc Switch Mode Power Supply GEN3-08-y
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE
More informationPro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationResistance Thermometers Model TR217, with Spring-Loaded Probe Tip
Electrical Temperature Measurement Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip WIKA Data Sheet TE 60.22 Applications Temperature measurement at bearings of: T Pumps T Gears T Motors
More informationHR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators
abc GB HR25 Solo Installation and User Instructions Models:- HR25 Solo HR25 Solo L HR25 Solo H HR25 Solo LH Through the Wall Heat Recovery Ventilators PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.
More informationZB0050 / ZB0051 ZB0070 / ZB0071
Operating instructions Safety Rope Emergency Stop Switches UK ZB0050 / ZB0051 ZB0070 / ZB0071 7390877 / 02 08/2013 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4 2.2
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationBROCHURE. Low voltage motors and drives for applications in explosive atmospheres
BROCHURE Low voltage motors and drives for applications in explosive atmospheres 2 ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS IN EXPLOSIVE ATMOSPHERES ABB LOW VOLTAGE MOTORS AND DRIVES FOR APPLICATIONS
More informationOPERATION AND MAINTENANCE INSTRUCTIONS
ATEX LED WORKLITE WL-85, WL-80 OPERATION AND MAINTENANCE INSTRUCTIONS CONTENTS EU Declaration of Conformity 3 Approval Codes/Certification 3 IECEx Scheme Certification 3 Special Conditions of Use (X Condition)
More information11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**
Assembly Instructions for: S1 Assembly to S Junction Instructions Boxes for: MS1 to MS Junction Boxes Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully before commencing
More informationGuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4
1. Introduction: This instruction manual contains important information regarding the safety instructions, installation, operation, maintenance and storage of the Guardbox limit switch boxes. The limit
More information11 Control Panels, Distribution Panels and Components
Control Panels, Distribution Panels and Components Motor Switches Explosion protection to CENELEC IEC For use in Zone and Zone Isolator Motor switching capacity Rated working voltage up to Rated working
More informationAccessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600
Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Installation Guide WBP-Box-IEN103320 IMEN-WBP-BOX Version 2.0 EN SMA Solar Technology AG Table of Contents Table of Contents
More informationThreaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35
Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 WIKA data sheet TE 60.03 for further approvals see page 7 Applications Machinery,
More informationPOWER FOR TOMORROW. Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service
POWER FOR TOMORROW TODAY The Eternity Technologies range is built using only the highest quality and most efficient production processes at our state-of-the-art manufacturing centre in the UAE. It is this
More informationMV Series Motors Operation & Parts Manual
MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US For use with M3V s/n 101057 & below, M3V-UK s/n 103013 & below, M5V & M5V-US s/n 102972 & below. EU Declaration of Conformity Finish Thompson
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL BC.
INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL ORBINOX SPAIN PolInd s/n-20270 ANOETA Tel:+34 943 698030 Fax:+34 943 653066 e-mail:orbinox@orbinoxcom ORBINOX CANADA, ORBINOX USA,, ORBINOX BRAZIL, ORBINOX
More informationHST -LS Interlocking device (Translation of Original Manual)
Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image
More informationDimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,
Assembly Instructions for junction boxes type: Assembly Instructions for: S1 to S / SFI1 to SFI / SFE1 to SFE S1 to S Junction Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully
More informationPAB Atex-certified centrifugal pumps
1 6036 EN PAB Atex-certified centrifugal pumps Technical data Delivery rate Q max = 305 l/min Delivery head H max = 20 m Temperature range 0 C to +60 C Quality Management DIN EN ISO 9001: 2008 Environmental
More informationUSER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..
d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer
More informationControl Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België
Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part
More informationAXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour
1.0 Introduction The Nuaire Axus range of Long Cased Axial Flow Fans are produced in sixteen case sizes from 315mm dia. to 1600mm dia. with duties up to 65m3/s. Impellers are manufactured in aluminium
More information3. Operating instructions: Minor 200
1. Technical specifications 3. Operating instructions: Minor 200 Copyright 2015 by Endecotts Ltd. 13 1. Setting up Technical specifications SIEVE SHAKER MODEL: Minor 200 General Information The Minor 200
More informationAppendix: Operation of Explosion- Protected Motors acc. to ATEX 100a
Page 1 of 8 Spare parts phone: 069 / 86 000 3-721 fax: 069 / 86 000 3-777 Motors Vibrators Type DV Operating Instructions Contents Page 1 Mounting and commissioning... 2 2 Electrical connection, characteristics...
More informationL: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L
Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:
More informationOperating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX
ATEX Type Certification marking for type L1X-EX, T1X-EX, T2X-EX Type of protection "d" explosion-proof enclosure Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX
More informationToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION
ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION II 2 G I M2 Ref. ID 2310, Rev. A Email: sales@cord-ex.com www.cordexinstruments.com CONTENTS 1. READ THIS FIRST 1. READ THIS FIRST 1 Liability 1 Trademark
More informationAEROSTAT HP-N-Ex Ionising Air Blower
SIMCO (Nederland) B.V. Postbus 71 NL-7240 AB Lochem Telefoon + 31-(0)573-288333 Telefax + 31-(0)573-257319 E-mail general@simco-ion.nl Internet http://www.simco-ion.nl Traderegister Apeldoorn No. 08046136
More informationROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators
ROM Series Installation Manual Valve Actuators Keeping the World Flowing Contents Section Page Health and safety 3 Storage 4 Mounting the actuator 4 Setting the actuator stop bolts 5 Cable connections
More informationMetal Position Switch Series 8074
> Dimensions and characteristic values according to EN 50041 > Replaceable contact element in flameproof enclosure > Positive opening contacts > Wide range of actuators > All actuators can be displaced
More informationEnglish. 1 of 5. Parts Supplied:
English Fitting Instructions: Daytona 675, Street Triple, Street Triple R, Tiger 800 and Tiger 800XC A96809 - Daytona 675 up to VIN 874, Street Triple and Street Triple R (79 kw models only) A96807 - Daytona
More informationTechnical Data PR VALVE PRESSURE REGULATING VALVE
Technical Data PR VALVE PRESSURE REGULATING VALVE Applies to the following models only: - PR Please read carefully before commencing installation HYTEK (GB) LIMITED, Delta House, Green Street, Elsenham,
More informationUniprep 2 Rotary scraping tool for pipes mm
Operating instructions and specifications for Uniprep 2 Rotary scraping tool for pipes 125-500mm Products by innovation not imitation Helping you make the right connections Models covered by this manual:
More informationLoad and Motor Switches, Load-Break Switches Series 8544
www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Alligator clip Auxiliary
More informationIBExU Institut für Sicherheitstechnik GmbH
[1] EC-TYPE EXAMINATION CERTIICATE according to Directive 94/9/EC, Annex 111 [2] Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres, Directive 94/9/EC [3] EC-Type Examination
More informationClarius EP PLUS LED FLOODLIGHT Installation Guide
Clarius Clarius EP PLUS LED FLOODLIGHT Installation Guide CERTIFICATION: SIRA09ATEX5159X AND IECEx SIR 09.0064X AND ABS 11-LD801943-PDA II 2 G D Ex emb IIC T4 Gb Ex t IIIC T103oC Db IP66/67 T4-20 oc to
More informationEdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION
EdgeLED TM Range THIS FITTING SHOULD NOT BE USED IN AREAS EXCEEDING 25 C AMBIENT AIR TEMPERATURE This fitting must be installed by a qualified electrician and wired in accordance with the latest edition
More informationSeries 500. Liquid Level Transmitters. Instruction Manual
Series 500 Liquid Level Transmitters Instruction Manual Contents Section Content Page 1 Introduction 1.1 General Overview 3 1.2 Mounting Options 3 2 Installation Notes 2.1 Transmitters 4 2.1.1 Model 510
More informationThe cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals
E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in
More informationLOG CHOP. Hydraulic Wood Guillotine. Owners Illustrated Instruction Book & Parts List
LOG CHOP Hydraulic Wood Guillotine Owners Illustrated Instruction Book & Parts List Grovebury Road, Leighton Buzzard, Bedfordshire. LU7 4UX. UK. Tel:01525 375157. Fax:01525 385222. Email: enquires@brownsagricultural.co.uk
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationIS1 I/O-Modules. BusRail Series General Information. Symbols. Conformity to Standards. Safety instructions. Function/Characteristics
Backplane bus for the IS1 system, constisting of data bus, PowerBus and address circuits For 2 or 4 modules Installation on 35 mm DIN rails NS 35/15 The BusRail can be interconnected for up to 18 modules
More information0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd
0CV2 0CV2 series dust explosion-proof three-phase asynchronous motor INSTRUCTIONS Siemens Standard Motors Ltd. 2017.02 1.0 Overview 0CV2 0CV2 series dust explosion-proof three-phase asynchronous motor
More informationIntegrated Valve Assemblies FORAC
The F-Series + Integrated Valve Assemblies De-pressurised Pneumatics The single piston has only one dynamic sealing ring under pressure. This single seal has a short stroke thus minimising frictional wear.
More informationInstallation and Service Instructions for EX Series Explosion-proof Switches
Installation and Service Instructions for EX Series Explosion-proof Switches ISSUE 4 50009662 WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application
More informationLED Emergency Luminaires
LED Emergency Luminaires THIS FITTING SHOULD NOT BE USED IN AREAS EXCEEDING 25 C AMBIENT AIR TEMPERATURE This fitting must be installed by a qualified electrician and wired in accordance with the latest
More informationTemperature controller- and limiters
65189 WIESBADEN Rüdigerstrasse 15 Telefon (0611) 761393 Telefax (0611) 711462 Temperature controller- and limiters For the assembly within the ex range after ATEX ZELM03ATEX0171 ZELM03ATEX0172X 0344 Type
More information320iB Mark II/436LiB, 525iB/536LiB, 530iBX
540-001 - 04.10.2018 Workshop manual 320iB Mark II/436LiB, 525iB/536LiB, 530iBX From S/N 20180100002 English Contents 1 Introduction 1.1 Document description... 3 1.2 Target group...3 1.3 Revisions...3
More information