1 MAYO COUNTY COUNCIL KILLALA WASTE WATER DISCHARGE LICENCE APPLICATION ATTACHMENT C C.1 Operational Information C.2 Outfall Design and Construction Dwg. Title Dwg. No. Location of Proposed Primary Discharge Point 10 Details of Proposed Primary Discharge Point 11 Ballycastle Road Proposed Pumping Station 12 Ballina Road Proposed Pumping Station 13
2 Killala Waste Water Discharge Application Attachment C.2 C.1 Operational Information C.1.1 Storm Water Overflows There are no existing or proposed storm water overflow points on the Killala wastewater collection network. C.1.2 Pumping Stations Existing Crossmolina Road Pumping Station This pumping station serves 55 County Council houses at Woodview Housing Estate. The pump operates for less than 2 hours per day and there is little or no variation in flow during wet weather, indicating that there is no stormwater draining to the sump. This station incorporates two 2950RPM, 4.05kW Pelger submersible pumps (duty & standby) which pump against a head of 7.6m. This rising main from this station is 100mm in diameter, 130m long and discharges to an existing manhole on the collection network. There is no emergency overflow from this pumping station. Ballina Road Pumping Station This pumping station was built to serve two factories on the Ballina Road, but only domestic sewage is discharged as both industries are dry operations. A current workforce of about 60 people is employed at the two factories. Pumping hours amount to 1 hour every 2 days. This pumping station incorporates two 1450RPM, 1.1kW HOMA submersible pumps. The rising main from this pumping station discharges into an existing higher manhole on the collection network. There is no emergency overflow from this pumping station. C.1/1
3 Killala Waste Water Discharge Application Attachment C.2 This pumping station will be replaced by a gravity sewer under the proposed Killala Sewerage Scheme. Quay Road Pumping Station Combined flows from part of the town centre and the south of the town drain to this pump sump. The pumps operate for as little as 4 hours a day during dry weather and can run for 24 hours during periods of heavy prolonged rainfall. This pumping station incorporates 2 No RPM, 6.5kW Zenit submersible pumps, which pump against a head of 11.4m. These pumps can act as dual or duty/standby pumps. A storm water holding tank is also provided in this pumping station to provide extra storage in the event of large flows. There is a total storage of 30m 3 provided. An emergency discharge located just under the roof slab drains, via a chamber which is fitted with a flap valve, to the foreshore. The 150mm dia. rising main discharges to an existing manhole higher up on the collection network. From there it flows by gravity to the primary outfall. Proposed It is proposed to construct two additional pumping stations under the Killala Sewerage Scheme; one on the Ballina Road and another larger station on the Ballycastle Road. As mentioned above, the existing Ballina Rd pumping station is to be designed out. Ballycastle Road Pumping Station This is to be the main pumping station on the proposed scheme pumping the effluent from the entire Killala sewerage scheme collection network, with the exception of the Ballina Road extension, through a new rising main to the proposed treatment works site. C.1/2
4 Killala Waste Water Discharge Application Attachment C.2 This is a large pumping station with a storage capacity of 140m 3. This is comprised of 88m 3 in the storm water holding tank, and the remaining 52m 3 in the wet well. It is proposed to have three pumps sitting in a dry well, two duty and one standby. The emergency overflow from this pumping will utilise the existing primary discharge outfall pipe as this will be superseded by the construction of the proposed treatment plant on the Ballina road. This overflow will only be active if the storm water storage tank is at capacity and it will be screened before discharge. The Ballina Road Pumping Station The pumping station on the Ballina Road will serve a number of houses on the Ballina Road, which are currently outside the boundary of the existing collection network. The rising main from the Ballina Road pumping station will discharge into a junction on the larger rising main (from Ballycastle road pumping station) rather than back into the main gravity collection network. This pumping station will only have a foul flow, which means the quantity of effluent will not vary greatly. It will only serve a relatively small catchment. This proposed pumping station will have a storage capacity of 23m 3 in the wet well, with no storm water holding tank. There will be two pumps sitting in a dry well, in a duty/standby configuration. There will be an emergency overflow incorporated into this pumping station however as the catchment is relatively small and it will only be pumping foul flow, it will only overflow in the event of a prolonged power failure. C.1/3
5 Killala Waste Water Discharge Application Attachment C.2 C.2 Outfall Design and Construction Wastewater Treatment Works Outfall Existing, SW1 (P) Waste water collected by the existing waste water collection network is not treated. It is discharged freely, unscreened, to mud flats in the Townplots West area of the town. At low tide there is only a small flow going from this area out to Killala Bay. The existing primary discharge outfall pipe is 450mm diameter and is fitted with a non return flap valve. Proposed, SW3 (P) It is proposed to use the former Asahi Synthetic Fibres Ltd outfall to discharge treated effluent from the new Wastewater Treatment Works to Killala Bay. This existing outfall pipe is approximately 5.3km in length. The outfall consists of; On shore section consisting of 577m of 600mm dia. and 2031m of 750mm dia. concrete pipe. Foreshore section consisting of 200m of 750mm dia. concrete pipe. In-shore section consisting of 1626m of 750mm dia. glass reinforced plastic (GRP) pipe. Off-shore section consisting of 157m of 750mm dia. GRP and 705m of 750m dia. steel pipe, at the end of which are 46 No. diffuser ports. CCTV surveys of the land section of the pipeline, and external survey of the marine section initially indicated that the pipe is in good condition. Some repairs may however need to be carried out before it is brought back into daily use. This rehabilitation will be included in the Civil Works Contract for the proposed scheme. C.2/1
6 Killala Waste Water Discharge Application Attachment C.2 Details of the proposed outfall are shown on drawing number 11. Secondary Discharge Points Existing There is only one secondary discharge point on the existing sewerage collection network. This is an emergency overflow from the Quay Road pumping station. When the capacity of the storm water holding tank in the pumping station has been reached, the effluent overflows through this high level pipe. This pipe extends into Killala Bay and is thought to be fitted with a non-return valve. Proposed Under the Killala Sewerage Scheme it is proposed to construct two pumping stations. Each of these pumping stations will include emergency overflows which will alleviate the problem of surcharging in the event of a power failure or abnormally high flow rates. In the case of the Ballycastle Road pumping station the emergency overflow will discharge when the stormwater holding tank is at capacity. It will then overflow into the pipeline currently being used as the primary outfall. As there is 140m 3 of storage incorporated into this pumping station the secondary discharge would only be active is rare circumstances (less than one per year). The secondary discharge point from the Ballina Road pumping station is to discharge into a stream on site, and eventually into Killala Bay. This secondary discharge will also only occur in rare circumstances as the 23m 3 of storage in this pumping station is adequate for the small sub-catchment it serves. Also this is not part of a combined system so rainfall does not affect this pumping station. C.2/2
7 Co en t ns of co For py in rig sp ht ect ow ion ne pu r r rp eq os ui es re o d nl fo y. ra ny he ru ot se.
8 EPA Export :01:39:48
9 EPA Export :01:39:48 Co en t ns of co For py in rig sp ht ect ow ion ne pu r r rp eq os ui es re o d nl fo y. ra ny he ru ot se.
10 EPA Export :01:39:48
Troqueer WwTW is located on the banks of the River Nith and serves the market town of Dumfries. The works
Troqueer WwTW 10m scheme to deliver capital maintenance, growth and odour control by Malcolm Robertson Bsc (Hons) Troqueer WwTW is located on the banks of the River Nith and serves the market town of Dumfries.
More informationFuel and Oil Separators
Fuel and Oil Separators PREMIERTECHAQUA.CO.UK Premier Tech Aqua UK s range of Conder Fuel and Oil Separators are for use with surface water drainage systems and are designed to prevent hydrocarbons (e.g.
More informationELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS. Ranges MX, V, K Discharge Size DN 80 - DN 150
ELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS Ranges MX, V, K Discharge Size DN 80 - DN 150 T h e s o u r c e f o r h i g h e f f i c i e n c y High Performance in Waste Water Pumping HOMA submersible waste
More informationAppendix B-6. Mechanical Equipment Design Calculation
Appendix B-6 Mechanical Equipment Design Calculation APPENDIX B.6 Mechanical Equipment Calculation (1) Design Flow 1. Design Conditions M3/day M3/hour M3/min M3/sec Design Maximum Daily Flow Design Maximum
More informationRELN Septic & Holding Tanks
RELN Septic & Holding Tanks New, Improved Tanks RELN s complete range of purpose designed black water tanks take quality and flexibility to the next level, with: Unique stepped ribs for greater strength
More informationThe Pump Matic Range
The Below Ground packaged pumping Stations Ideal for - Sewage, Wastewater, Stormwater Pump Technology Ltd, manufactures its own pumping station tanks. We have complete control over the construction, quality
More informationSECTION 12: TRAFFIC. For inspection purposes only.
SECTION 12: TRAFFIC 121 INTRODUCTION 12.1.1 Background This chapter of the Environmental Impact Statement (EIS) has been prepared by WSP Ireland Ltd and reviews the impact of the proposed Inert Soil Recovery
More informationENVIRONMENTAL & ENGINEERING SERVICES DEPARTMENT
CITY OF LONDON ENVIRONMENTAL & ENGINEERING SERVICES DEPARTMENT WASTEWATER TREATMENT OPERATIONS VAUXHALL WASTEWATER TREATMENT PLANT 2013 ANNUAL REPORT FEBRUARY 2014 Vauxhall Wastewater Treatment Plant 2013
More informationTodd Carlson Program Coordinator Engineering MMSD PP I/I Summit 2.0 October 15,
Todd Carlson Program Coordinator Engineering MMSD PP I/I Summit 2.0 October 15, 2015 1 North Shore of Lake Superior 883 feet of Elevation Aging Sanitary/Storm Sewer System dating back to 1880 s Second
More informationBacteria TMDLs for Brays Bayou November 11, 2008
Bacteria TMDLs for Brays Bayou November 11, 2008 PARSONS Outline Watershed Overview Pollutant Pollutant Source Assessment Technical Approach: Load Duration Curves TMDL TMDL Calculations Brays Bayou Watershed
More informationCSO/STORMWATER MANAGEMENT. Hydrovex VHV / SVHV Vertical Vortex Flow Regulator
CSO/STORMWATER MANAGEMENT Hydrovex VHV / SVHV Vertical Vortex Flow Regulator HYDROVEX VHV / SVHV VERTICAL VORTEX FLOW REGULATOR INTRODUCTION One of the major problems of urban wet weather flow management
More informationATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING
ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING 1.0 General 1.1 The work covered by this section consists of providing all labor, equipment, material and supplies, insurance, accessories, tools, transportation,
More information2. Katikati. 2.1 Infrastructure Schedule. Katikati Utilities. Project Number. Project Construction Year. Funding Source (percentage) Costs 2015 ($)
2. Katikati 2.1 Infrastructure Schedule Katikati Utilities Number Proposed Construction Year Costs 2015 ($) Funding Source (percentage) WS2 WS3 WS4 WS5 WS 9 WS 10 New Water supply (200mm dia) Tetley Rd
More informationDIRECTIONS ISSUED TO LICENSED PROVIDERS PURSUANT TO STANDARD LICENCE CONDITION B1 THE WATER INDUSTRY COMMISSION FOR SCOTLAND.
DIRECTIONS ISSUED TO LICENSED PROVIDERS PURSUANT TO STANDARD LICENCE CONDITION B1 BY THE WATER INDUSTRY COMMISSION FOR SCOTLAND 17 May 2007 1 DEFAULT SERVICES, STANDARDS AND MAXIMUM TARIFFS FOR WATER AND
More informationCONTENT OIL/WATER SEPARATOR TANKS FOR ALL INDUSTRIES FIBREGLASS. 1. General Information. 2. Important features. 3. Areas of applications
FIBREGLASS OIL/WATER SEPARATOR TANKS FOR ALL INDUSTRIES CONTENT 1. General Information 2. Important features 3. Areas of applications 4. Principle of oil separator 5. Choice of oil/water separator 6. Sizing
More informationAPPENDIX B FUNCTIONAL DESIGN SPECIFICATIONS (Sequence of Operation)
APPENDIX B FUNCTIONAL DESIGN SPECIFICATIONS (Sequence of Operation) B.1 WATER SUPPLY FACILITIES 1. General A. The tag number of the equipment comprise three designations (W10 CM 01), where the three designations
More informationCUYAHOGA COUNTY, OHIO ADDENDUM NUMBER 2 FOR THE CLEANING AND TELEVISING OF SEWERS IN VARIOUS COMMUNITIES FOR A TWO-YEAR PERIOD,
CUYAHOGA COUNTY, OHIO ADDENDUM NUMBER 2 FOR THE CLEANING AND TELEVISING OF SEWERS IN VARIOUS COMMUNITIES FOR A TWO-YEAR PERIOD, 2017-2018 FOR THE CUYAHOGA COUNTY DEPARTMENT OF PUBLIC WORKS RQ# 39104 BIDS
More informationABS lifting station Synconta
15975187GB (03/2006) 106800 GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions 601 801 901 901L 902 902L Contents 1 General... 3 1.1 Application areas...
More informationCITY OF WESTON, a municipal corporation SEWERAGE AND SEWAGE DISPOSAL SERVICE
P.S.C. W. Va. Tariff No. 16 Canceling P.S.C. W. Va. TariffNo. 15 CITY OF WESTON, a municipal corporation OF WESTON, WEST VIRGINIA RATES, RULES AND REGULATIONS FOR FURNISHING SEWERAGE AND SEWAGE DISPOSAL
More informationRosedale Sanitary Sewer Feasibility Review Report
Rosedale Sanitary Sewer Feasibility Review Report Submitted by: WEDLER ENGINEERING LLP 201 9300 Nowell Street Chilliwack BC V2P 4V7 Phone: 604 792 0651 Wedler File No: C13 5032/A December 6, 2013 STATEMENT
More informationBypass Pumping Brian Lee Municipal Sales Rev Bypass Pumping
Bypass Pumping Brian Lee Municipal Sales Rev. 2018 1 Bypass Pumping 2 1 Bypass Pumping 3 Bypass Pumping 2 Bypass Pumping Bypass Pumping 6 3 Topics Covered Definition of bypass Evaluation of an application
More informationRAS & WAS Pumps (FLYGT Pump)
RAS/WAS Pumping Pumping of sludge from the secondary clarifiers to the aeration tanks maintains active biomass in the aeration tanks This is referred to as return activated sludge (RAS) pumping RAS pumps
More informationSTRUCTURE 5A PURPOSE
STRUCTURE 5A This structure is a six unit pumping plant located on the south side of U.S. Highway 441 and Canal 51 (West Palm Beach Canal) between the canal and the borrow canals of Levees 7 and 40 about
More informationANGLIAN WATER SERVICES LTD. Great Billing Wastewater Treatment Works Odour Management Plan
ANGLIAN WATER SERVICES LTD. Great Billing Wastewater Treatment Works Odour Management Plan Document Approval Graham Hackney- (AWS) Catchment Manager Pat Green- (AWS) Odour Practitioner Group Date This
More informationCapital Improvement Plan Review
City of Manhattan Beach Public Works Department Fiscal Year 2014/2015 2018/2019 Capital Improvement Plan Review Community Meeting: April 10, 2014 Objectives Creating the Capital Improvement Plan Funding
More informationGrease Inspection Program
Grease Inspection Program Dublin San Ramon Services District (DSRSD) must comply with federal and state pretreatment regulations. The Publicly Owned Treatment Work s (POTWs) are charged with enforcing
More informationSUBMERSIBLE ELECTRIC PUMPS FOR FOUL WASTE WATER (VORTEX) in cast iron
) Submersible electric pumps for foul waste water, cast iron. APPLICATIONS Evacuation of civil and industrial waste water Effluent treatment Draining underground areas Handling fluids containing suspended
More informationFlygt N-Pumps 3085, 3102 & 3127
Flygt N-Pumps 3085, 3102 & 3127 For reliable and efficient wastewater handling The ConCepT Flygt N-Pump series Reduced pumping efficiency, high energy and maintenance costs shouldn t be a fact of life
More informationCAPITAL EXPENDITURE. Community Facilities. Community Services. District Planning & Regulatory Services. 2024/25 LTP Budget. 2018/19 LTP Budget
Community Facilities Local Govt Centre - Library/LGC extension scoping/plans 100 100 Local Govt Centre - Library / LGC extension 1,400 100 Local Govt Centre - Office revamp 30 100 Local Govt Centre - Carpet
More informationBacteria TMDLs for Halls Bayou November 10, 2008
Bacteria TMDLs for Halls Bayou November 10, 2008 PARSONS Outline Watershed Overview Pollutant Pollutant Source Assessment Technical Approach: Load Duration Curves TMDL TMDL Calculations Halls Bayou Watershed
More informationSewerage Services.
Sewerage Services jballosewage@gmail.com www.jballosewage.com JB ALLO SEWAGE The experience you need and quality you deserve Pumping Services Grease Trap Sump Pit Lift Station Septic Tank Sewage Tank Holding
More informationCity of Grand Forks Staff Report
City of Grand Forks Staff Report Committee of the Whole December 1, 016 City Council December 19, 016 Agenda Item: Bids for City Project No. 7551 Lift Station No. 17 & 17A Rehabilitation Submitted by:
More informationAQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual
AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual For Single-Wall and Double-Wall Fibreglass Underground Storage Tanks This Aquator Commercial Oil Water Separator (OWS)
More informationSeptic Tank. Installation Guidelines
Septic Tank Installation Guidelines INSTALLATION GUIDELINES FOR WPL SEPTIC TANKS These guidelines represent Best Practice for the installation of spherical SEPTIC tanks. It must be noted, however that
More informationAQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual
AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual This Aquator Commercial Oil Water Separator (OWS) Operating and Maintenance Manual gives instructions for single-wall
More informationHOMA Product Range. Electric Submersible Sewage Pumps Ranges K, KX. The source for world wide pump technology. Discharge Size DN 200 up to DN 400
The source for world wide pump technology HOMA Product Range Electric Submersible Sewage Pumps Ranges K, KX Submersible drainage pumps Contractor pumps Drainage pumps for emergency application Deepwell
More informationD-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features
PN 16 / 25 Wastewater Combination Air Valve for Wastewater PATENTED EuroC-D023SWG-15-2 Description The D-023 Combination Air Valve combines an air & vacuum component and an air release component in a single
More informationB2. Fueling Operations
B2. Fueling Operations Commercial / Industrial / Institutional & Municipal Pollution Prevention Goal: Prevent or reduce the risk of discharge of pollutants to stormwater from vehicle and equipment fueling
More informationSecondary Digester Cleaning to Meet Ohio Sludge Rules. Timothy McCann AECOM Keith Bovard Rocky River WWTP
Timothy McCann AECOM Keith Bovard Rocky River WWTP Agenda Rocky River WWTP Background Ohio Sludge Rules EPA Request for Alternative Digester Cleaning Project Page 2 Rocky River WWTP Background and History
More informationELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS. Rangess AK, KXAKX Discharge Size DN 200 DN
ELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS Rangess AK, KXAKX Discharge Size DN 200 DN 500 T h e s o u r c e f o r h i g h e f f i c i e n c y High Performance in Waste Water Pumping HOMA submersible waste
More informationVehicle and Equipment Fueling
Vehicle and Equipment Fueling SC-20 Objectives Cover Contain Educate Reduce/Minimize Description Spills and leaks that occur during vehicle and equipment fueling can contribute hydrocarbons, oil and grease,
More informationMYERS MODELS 4RC AND 4RCX
3450 RPM 1150 and 1750 RPM MYERS MODELS 4RC AND 4RCX SOLIDS HANDLING WASTEWATER PUMPS (4RCX only) STANDARD (4RC) AND HAZARDOUS LOCATION (4RCX) CONSTRUCTION WWW.FEMYERS.COM MYERS MODELS 4RC AND 4RCX Solids
More informationAppendix C Capital Improvement Program Project Descriptions and Details
Appendix C Capital Improvement Program Project Descriptions and Details GIG HARBOR WW COMP PLAN DRAFT CAPITAL IMPROVEMENT PROGRAM LIFT STATION COST ESTIMATE Lift Station 1 Item Qty Units Unit Cost Extended
More informationPublic Information Centre
Junction Street Wastewater Pumping Station & Forcemain Schedule B Municipal Class Environmental Assessment Study Public Information Centre June 28, 2017. 6:00 to 8:00 pm. The Burlington Performing Arts
More information28th February, 2003 Statutory Instruments 75 GOVERNMENT OF ZAMBIA. The Water Supply and Sanitation Act (Act No. 28 of 1997)
28th February, 2003 Statutory Instruments 75 GOVERNMENT OF ZAMBIA STATUTORY INSTRUMENT NO. 26 OF 2003 The Water Supply and Sanitation Act (Act No. 28 of 1997) The Water Supply and Sanitation (Transfer
More informationBettendorf City Council Joint Use Sewer Administrative Consent Order February 4, 2013
Bettendorf City Council Joint Use Sewer Administrative Consent Order February 4, 2013 History/Timeline Interceptor Sewers/Locations (approximately 13 miles) Strategy for Financial Plan, Plan of Action
More informationSpecifier s Document. Features and Benefits. Construction
Specifier s Document The Dump-Ezy product has evolved out of a need to provide a mechanism for dealing with waste from portable toilets in all sorts of mobile vehicles and boats. The more sophisticated
More informationGCG ASSOCIATES, INC. PROFESSIONAL CIVIL ENGINEERS AND LAND SURVEYORS 84 Main Street Wilmington, Massachusetts 01887
GCG ASSOCIATES, INC. PROFESSIONAL CIVIL ENGINEERS AND LAND SURVEYORS 84 Main Street Wilmington, Massachusetts 01887 Phone: (978) 657-9714 Fax: (978) 657-7915 December 31,2.012 Mr. Charles Aspinwall Town
More informationOIL & GAS FIELD SYSTEMS
OIL & GAS FIELD SYSTEMS Washing + CONTAINMENT + TREATMENT = ground water protection The Solution is Clear with Riveer SM Engineered Wash Water Recovery Systems OIL & GAS Washing + Containment + Treatment
More informationForest Hill Street Clutter study
1 Local Fund and Street Clutter London Borough of Lewisham Forest Hill Street Clutter study Colin Davis Associates Traffic and Urban Design consultants January 2010 020 8398 7837 colinjdavis@aol.com www.publicrealm.info
More informationMYERS MODELS 4V AND 4VX
MYERS MODELS 4V AND 4VX SOLIDS HANDLING WASTEWATER PUMPS STANDARD (4V) AND HAZARDOUS LOCATION (4VX) CONSTRUCTION WWW.FEMYERS.COM MYERS MODELS 4V AND 4VX Solids Handling Wastewater Pumps The Right Choice
More informationSUBMERSIBLE PUMPS Lifting of wastewater containing little pollution 50 Hz
OPerating limits Flows rates up to : 1 m 3 /h Heads up to : m Temperature range : + 3 to 35 C Free passage : 10 mm ND of discharge orifice R1 1/ SBS--0 JETSON SUBMERSIBLE PUMPS Lifting of wastewater containing
More informationMYERS MODELS 6VC & 6VCX
MYERS MODELS 6VC & 6VCX 6" SOLIDS HANDLING WASTEWATER PUMPS STANDARD (6VC) AND HAZARDOUS LOCATION (6VCX) CONSTRUCTION WWW.FEMYERS.COM MYERS MODELS 6VC & 6VCX Solids Handling Wastewater Pumps High Operating
More informationBID FORM PART A. Total Quantity 1 LS $ - 2a Surveying, Layout, and Field Staking 1 LS $ - 2b Maintenance of Traffic 1 LS $ -
BID FORM PART A Name & Category Unit Unit Cost (B) Cost (AxB) GENERAL REQUIREMENTS 1 Mobilization (Maximum 3.0% of the total Contract Price) 1 LS $ - 2a Surveying, Layout, and Field Staking 1 LS $ - 2b
More informationBaltimore City Opportunities The Year Ahead
Opportunities The Year Ahead Presented By: Azzam Ahmad, Acting Chief Office of Engineering and Construction November 7, 2017 FY 2018 Capital Improvement Program Summary (Millions) 6 Solid Waste Program
More informationWaste Water Solutions
Waste Water Solutions Mono is a leading name in the design, manufacture and supply of progressing cavity pumps, parts, grinders, screens and packaged solutions, worldwide. We have 7 international sites
More informationRAINWATER HARVESTING INSTALLATION GUIDE RH High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application
RAINWATER HARVESTING INSTALLATION GUIDE RH9521-12 High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application RH9521-12 Vortex Filter Operation and Maintenance Overview The RH9521-12
More informationTHE USE OF SUBMERSIBLE PUMPS TO IMPROVE EDUCTIONS FROM SEWER PUMPING STATIONS. Ian Syer. us Utility Services
THE USE OF SUBMERSIBLE PUMPS TO IMPROVE EDUCTIONS FROM SEWER PUMPING STATIONS Paper Presented by : Ian Syer Authors: Ian Syer, Senior Sewerage Coordinator, Warren Roberts, Senior Mech Coordinator, us Utility
More informationMYERS MODELS 4VC & 4VCX
MYERS MODELS 4VC & 4VCX 4" SOLIDS HANDLING WASTEWATER PUMPS STANDARD (4VC) AND HAZARDOUS LOCATION (4VCX) CONSTRUCTION WWW.FEMYERS.COM MYERS MODELS 4VC & 4VCX Solids Handling Wastewater Pumps Cut Your Pumping
More informationRain Harvesting Pty Ltd
WATER DIVERTER Available from: PO015/3 Rain Harvesting Pty Ltd 28-34 Reginald Street Rocklea Q 4106 Australia info@rainharvesting.com.au Tel: (07) 3248 9600 Fax: (07) 3248 9699 Prevents contaminated water
More informationGREASE INTERCEPTOR REQUIREMENTS
CALAVERAS COUNTY WATER DISTRICT GREASE INTERCEPTOR REQUIREMENTS HANDOUT 05 Calaveras County Water District Water and Sewer Building Service Standards GREASE INTERCEPTOR REQUIREMENTS GENERAL The following
More informationMYERS MODELS 4R AND 4RX
MYERS MODELS 4R AND 4RX SOLIDS HANDLING WASTEWATER PUMPS STANDARD (4R) AND HAZARDOUS LOCATION (4RX) CONSTRUCTION WWW.FEMYERS.COM MYERS MODELS 4R AND 4RX Solids Handling Wastewater Pumps The Right Choice
More informationCONCEPTUAL UTILITY REPORT FOR THE CANYONS PHASE 1 CITY OF CASTLE PINES, CO
CONCEPTUAL UTILITY REPORT FOR THE CANYONS PHASE 1 CITY OF CASTLE PINES, CO PREPARED FOR: SHEA HOMES 9380 STATION ST., SUITE 600 LONE TREE, CO 80124 PHONE: 303-791-8180 CONTACT: RYAN MCDERMED PREPARED BY:
More informationCSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve
CSO/STORMWATER MANAGEMENT HYDROVEX CCV Check Valve HYDROVEX CCV CIRCULAR CHECK VALVE APPLICATION The HYDROVEX CCV Check Valve is designed for use in water and sewage. It has no reinforcement and is especially
More informationSection 5 - Operations and Maintenance Program
Section 5 - Operations and Maintenance Program A. Introduction The intent of this section of the SSMP is to describe the current operation of the City s wastewater collection system. There are five areas
More informationChapter 8.0 PROPOSED CAPITAL IMPROVEMENT PROGRAM
Chapter 8.0 PROPOSED CAPITAL IMPROVEMENT PROGRAM This chapter presents the proposed Capital Improvement Program (CIP) for the District based on the findings of this Master Plan. The Master Plan primarily
More informationSouthern Nevada Water Authority Lake Mead Intake No. 3. The Last Straw?
Southern Nevada Water Authority Lake Mead Intake No. 3 The Last Straw? WESTCAS October 29, 2015 Underlying Intake No. 3 Factors Lake Mead is the primary water source for So. Nevada 90% of supply No guarantees
More informationDGN. Set-back vortex impeller. submersible pumps PRODUCT CATALOGUE General characteristics
submersible pumps PRODUC CAALOGUE 0 Set-back vortex impeller All product images are indicative only General characteristics Set-back vortex impeller motor power poles discharge free max flow rate max head,
More informationIndustries. Septic Tanks
Industries Septic Tanks South Australia s leading manufacturer of pre-cast concrete products including Ri Treat waste water treatment, trades waste arrestors, septic tanks and rainwater tanks www.ri-industries.com.au
More informationMultilift M, MD, MDV, and MD1 ranges
Multilift_front.qxd 19-05-2006 13:32 Side 1 GRUNDFOS WASTEWATER Multilift M, MD, MDV, and MD1 ranges 303_616_br_lifting_uk.qxd 22/02/05 8:46 Side 2 Grundfos Lifting Stations Reduced costs and optimised
More informationFlygt Packaged Pumping Stations A comprehensive range of products to suit many applications
Flygt Packaged Pumping Stations A comprehensive range of products to suit many applications Packaged Pumping Stations As we build in more remote and inaccessible areas, the need to pump wastewater to treatment
More informationfirst flust water diverters water quality first downpipe, post/wall mounted and in-ground diverters
water quality first downpipe, post/wall mounted and in-ground diverters Available in kit form just add PVC pipe Simple, effective and easy to install Includes Slow Release Control Valve - empties after
More informationCity Hall 539 Phoenix Street South Haven, Michigan Telephone (269) Fax (269)
City of South Haven City Hall 539 Phoenix Street South Haven, Michigan 49090-1499 Telephone (269) 637-0700 Fax (269) 637-5319 Dunkley and Black River Infrastructure Improvements Dunkley - Dyckman Avenue
More informationCONTRACT TERM: APRIL 28, 2018 THROUGH APRIL 27, 2020 RES. NO
CONTRACT AWARD AB2018-04 SLUDGE AND SEPTAGE REMOVAL AND SEWER LINE CLEANING FOR THE COUNTY OF MERCER FOR A PERIOD OF TWO (2) YEARS BID OPENING DATE: APRIL 5, 2018 CONTRACT TERM: APRIL 28, 2018 THROUGH
More informationWaste Water Solutions
Waste Water Solutions Mono is a leading name in the design, manufacture and supply of progressing cavity pumps, parts, grinders, screens and packaged solutions, worldwide. We have 7 international sites
More informationRULES FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSIONS CHAPTERS APPROACH
PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSIONS TITLE 47 SUPPLY VESSELS SECTION 6 PIPING CHAPTERS A B C D E F G H T APPROACH MATERIALS AND MANUFACTURE - See
More informationINSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS
INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS CONTENTS Introduction Safety Operating Principle System Installation Initial Startup System Operations Troubleshooting Maintenance
More informationACO Water Management: Civils + Infrastructure
ACO Water Management: Civils + Infrastructure Uniclass JR12/JR23 L731 CI/SfB (52.7) ACO Q-Brake Vortex Vortex flow controls ACO Q-Brake Vortex Introduction to the ACO Group Throughout the world, the ACO
More informationCity of St. Pete Beach Model Capacity Report Addendum
Model Capacity Report - Addendum City of St. Pete Beach Model Capacity Report Addendum Prepared for: City of St. Pete Beach 155 Corey Avenue St. Pete Beach, FL 33706 Prepared By: Kimley-Horn and Associates,
More informationEnvironment Restoration Operations Solid Waste Management Unit (SWMU) 52: Filling Tanks 2 and 4 with a Permanent Insoluble Material - September 2013
University of New Mexico UNM Digital Repository Environmental Restoration Sandia National Labs/NM Technical Reports 10-9-2013 Environment Restoration Operations Solid Waste Management Unit (SWMU) 52: Filling
More informationMANHOLE INDEX INDEX CONCRETE MANHOLE SPECIFICATIONS ASTM SPECIFICATIONS
MANHOLE INDEX INDEX M1...STANDARD STORM MANHOLE ASSEMBLY A1 M2...STANDARD MANHOLE ASSEMBLY A2 M3...CONICAL MANHOLE ASSEMBLY A3 M4...CONICAL MANHOLE ASSEMBLY A4 M5...CONICAL MANHOLE ASSEMBLY A5 M6...CONICAL
More informationCATALOGUE SEWAGE MANHOLES
CATALOGUE SC SEWAGE MANHOLES Table of contents TABLE OF CONTENTS Introduction 4 Inspection chamber, type 315 7 Inspection chamber, type 400 10 Inspection chamber, type 425 14 Assembly instruction 19 Catch
More informationWater Treatment Plant Historical Timeline
Water Treatment Plant Historical Timeline 1874 The citizens of the the Village of Evanston, with a population of 3500, started to build a communal water system. The system consisted of a 16 inch intake
More informationMODEL 7ASX-8 SPECIFICATION
MODEL 7ASX-8 SPECIFICATION 1.0 General Specifications There shall be furnished one (1) one only Grind Hog TM Model 7ASX-8 HEAVY DUTY Comminutor as manufactured by G.E.T. Industries Inc. with rotation in
More informationDRD - DRS - DRF. SUBMERSIBLE ELECTRIC PUMPS FOR SEWAGE in cast iron
DRD Cast iron submersible electric pumps for sewage with impeller with several channels APPLICATIONS Moving sewage, foul liquids in general Emptying seepage water Emptying cesspits Draining excavations
More informationSUBMERSIBLE ELECTRIC PUMPS FOR FOUL WASTE WATER (SINGLE CHANNEL) in cast iron
Submersible electric pumps for foul water. APPLICATIONS Evacuation of civil and industrial waste water Effluent treatment Draining underground areas Handling fluids containing suspended solids / filaments
More information/ /
This document is brought to you by 01371 850537 / info@ohel.co.uk / www.ohel.co.uk Domestic Wastewater Treatment SOLIDO The Natural Solution The SOLIDO. A simple and professional solution for domestic
More informationOPERATIONS AND MAINTENANCE PLAN
OPERATIONS AND MAINTENANCE PLAN FOR LAKES HIGHWAY DISTRICT PREPARED BY: LAKES HIGHWAY DISTRICT ERIC W. SHANLEY, P.E. DISTRICT ENGINEER Table of Contents Executive Summary... 4 Identification... 4 Scope...
More informationFor inspection purposes only.
6 Section D.1.3 Line Maintenance. Process Description The Line Maintenance Division, located primarily on the ramp at Dublin Airport provides aircraft turnaround, and aircraft maintenance support to contracted
More informationWestern Virginia Water Authority Schedule of Monthly Water Rates Roanoke City and Roanoke County Customers
Schedule of Monthly Water Rates Volume Charge per 1,000 Gallons All Customers Current Rate Proposed Rate First Tier $3.00 $3.00 Second Tier $3.75 $4.00 Third Tier $4.00 $4.25 Irrigation $3.75 $4.00 Base
More informationWASH SYSTEM. Instructions for Use
WASH SYSTEM Instructions for Use COMPONENTS LIST THESE SYSTEMS MUST BE CORRECTLY INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF REGULATORY WATER AUTHORITY PRIOR TO USE Pre-Filter / Release Valve Outlet Water
More informationWater-Monitoring Report, November 19, 2008
Water-Monitoring Report, November 19, 2008 Below is a copy of the sampling report update for Hempstead Harbor through November 5 for the 2008 water-monitoring season. The narrative and data are provided
More informationOil Water Separators Product Range
Industrial Water Treatment and Recycling Specialists Oil Water Separators Product Range 1800 353 788 www.cleanawater.com.au Oil Separators Total Range Cleanawater provide the largest range of oil water
More informationSMX. Self-priming magnetic drive pumps Magnetic drive pumps with an excellent balance of features and performance GFRPP
SMX s e r i e s Self-priming magnetic drive pumps Magnetic drive pumps with an excellent balance of features and performance Self-priming magnetic drive pumps Main material GFRPP The SMX is a horizontal
More information3) The water conductor system consisting of RCC, partly cut and cover, conduit of size 10.5m x 7m and m long to lead the water to the forebay.
Project: Mannapitlu Mini Hydel Scheme - 15 MW Overview: Mannapitlu Mini Hydel Scheme is the first of the 4 cascading Mini Hydro Electric Projects planned on Gurupur river in Dakshina Kannada District of
More informationSelecting Grease Haulers and Treatment Facilities
A F A C T S H E E T F O R Selecting Grease Haulers and Treatment Facilities Grease Goblin Fats, Oils and Grease (FOG) are commodities that if handled properly can be treated as a valuable resource. P 2
More informationPORTER TOWNSHIP CASS COUNTY, MICHIGAN PUBLIC WORKS SECTION PART 60 SEPTAGE RECEIVING ORDINANCE ORDINANCE #
PORTER TOWNSHIP CASS COUNTY, MICHIGAN PUBLIC WORKS SECTION PART 60 SEPTAGE RECEIVING ORDINANCE ORDINANCE # 8-02-11 An ordinance to provide for the disposal of septage waste at a licensed facility; authorize
More informationThere was an excessive accumulation of grease in the 820 Pump Station.
June 19, 2009 Barrett Harrison, Mayor Blytheville WWTP - West P.O. Box 1784 Blytheville, AR 72315 RE: Sanitary Sewer Overflow Inspection - West AFIN: 47-00145 NPDES Permit No.: AR0022560 Dear Mr. Harrison:
More informationThis Chapter provides a technical description of the proposed facility and also provides an overview of the planned Project activities and location.
4 PROJECT DESCRIPTION This Chapter provides a technical description of the proposed facility and also provides an overview of the planned Project activities and location. 4.1 LOCATION The Eastern Mole
More informationREGULATION- PM 10: Ships Ballast Water Management
REGULATION- PM 10: Ships Ballast Water Management 10.1. General Requirements 10.2 Ships Precaution for Loading Ballast 10.3 Ballast Water Management Plan 10.4 Reporting of Ballast water Reporting Form
More information