System User Interface

Size: px
Start display at page:

Download "System User Interface"

Transcription

1 System User Interface

2 System UI Configurations Run Screen Items Tools Setup Items Auxiliary Inputs Calibrations

3 Configuration Flexibility

4 Machine support Supports up to two base machine configurations Each base configuration supports a machine type of: Sprayer Liquid Fertilizer Toolbar Anhydrous Ammonia Toolbar User Interface and functionality is specific to machine type

5 Profiles Each base machine can support up to four profiles Allow for machines that have multiple boom setups Examples: 90 /120 roll over booms Nozzles on 20 center, drops on 30

6 Machine Dependent UI Sprayer Particle size monitoring Min/Max pressure warnings Solution pump speed monitoring Spray nozzles support Predefined ISOBUS nozzles Up to 50 custom nozzles Nh3 toolbar Liquid/Vapor state monitoring Nh3 temperature monitoring Container fills/edits by tank %

7 Run Screen Content GUI boom state to show Switch on, section spraying Switch on, section off by AutoSwath Switch off GUI container level Fluid level changes as container empties Color changes when countdown threshold is reached

8 Sprayer Run Screen GUI pressure gauge with integrated droplet size monitor Configurable pressure gauge range to make specific to current spray activity GUI display of spray nozzle in use Quick access to: Nozzle configuration Controller settings System diagnostics

9 Run Screen Items

10

11 Density Conversion

12 Target Rate

13 Ground Speed

14 Actual Rate

15 Container Settings

16 Nozzle Settings

17 Pressure Settings

18 Totals

19 Tools

20 Tools Boom Prime Allows operator to set a prime pressure and easily prime the boom to the set pressure Maintains the prime pressure when all sections are off Requirements Pressure sensor must be installed and calibrated If a pressure sensor is not being used the system still has PWM Standby Used for PWM Control Valve types only

21 Tools Nh3 Tube Check Allows the operator to check for plugged knives with the toolbar raised Requirements Operator has to accept a warning Section valve switches must be turned on Operator has to hold the tube check button Section valves open and control valve increments open to start dispensing product When operator releases button valves close

22 Setup Items

23

24 Manage Profiles

25 Manage Nozzles

26 Servo Control Valve

27 PWM Control Valve

28 PWM Settings Tool

29 Look Aheads

30 Alarm Settings

31 System Settings

32 Nozzle Attribute Setup

33 Particle Size Classification

34 Pressure Gauge for AI11004

35 Auxiliary Input Setup

36 Switch Assignments

37 Calibrations

38 Calibrations All calibrations have been removed from the configuration A single menu to access for all calibrations Pressure (Up to 3 sensors) Flow Meter Pump Speed Ground Speed

39

40 Pressure Sensor Calibrations

41 Pressure Sensor Manual Calibration Manually Enter mv/bar or Use Calculator

42 Multiple Set Point

43 Flow Meter Calibrations

44 Manual Calibration Manual Calibration Manually Enter pulses/liter

45 Static Dispense Volume

46 Field Dispense Volume

47 Nozzle Catch Method

48 Pump Sensor Calibration

49 Pump Sensor Calibration Manually enter number of pulses/revolution of the pump speed sensor

50 Ground Speed Calibration

51 Ground Speed Sensor Manual Calibration Manually Enter Pulses/Meter Distance Calibration

52 Task Controller

53 AGL Task Controller Task Controller allows the following: Integration with the Display s map screen Automatic Swath Control Prescription Rate Control Data logging to the.agdata file Display handles products/mixes

54 Questions

CFX-750 Display with the Field-IQ System: Spraying /Strip Till/Anhydrous Application Quick Reference Card

CFX-750 Display with the Field-IQ System: Spraying /Strip Till/Anhydrous Application Quick Reference Card CFX-750 Display with the Field-IQ System: Spraying /Strip Till/Anhydrous Application Quick Reference Card RUN SCREEN The Trimble CFX-750 display is a touchscreen display that is configured and run by tapping

More information

Installation Instructions ISOBUS Liquid ECU

Installation Instructions ISOBUS Liquid ECU Installation Instructions ISOBUS Liquid ECU Liquid Fertilizer & Ammonia Display Screen Sprayer Display Screen Last Update: 3/1/2018 SW Version Liquid v.01.00.04.00 - ECU HW: 1.6-1.7 SW Version Liquid v.02.00.01.00

More information

CONTROL SYSTEMS FOR PRECISION FARMING. IntelliAg puts the future of application control in your cab providing state-ofthe-art

CONTROL SYSTEMS FOR PRECISION FARMING. IntelliAg puts the future of application control in your cab providing state-ofthe-art CONTROL SYSTEMS FOR PRECISION FARMING IntelliAg puts the future of application control in your cab providing state-ofthe-art communication between implement and tractor. INTELLIAG CONTROL SYSTEMS Compatible

More information

Full screen alarms identify abnormal or failed operation on all enabled system components/controls

Full screen alarms identify abnormal or failed operation on all enabled system components/controls The world s most versatile controller IntelliAg puts the future of application control in your cab, providing state-of-the-art communication between implement and tractor. This precision farming system

More information

ISOBUS Product Control Installation & Operation Manual. Manual No Rev. F 7/16 E28148

ISOBUS Product Control Installation & Operation Manual. Manual No Rev. F 7/16 E28148 ISOBUS Product Control Installation & Operation Manual Manual No. 016-0171-362 Rev. F 7/16 E28148 Copyright 2016 Disclaimer While every effort has been made to ensure the accuracy of this document, Raven

More information

RADION Automatic sprayer control Software version 1.07

RADION Automatic sprayer control Software version 1.07 RADION 8140 U S E R G U I D E Automatic sprayer control Software version 1.07 Safety information TeeJet Technologies is not responsible for damage or physical harm caused by failure to adhere to the following

More information

OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD. PART NUMBER Rev.

OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD. PART NUMBER Rev. 8160 OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD PART NUMBER 39300030 Rev. E Table of Contents 1 TABLE OF TITLE CONTENTS 39300030 Rev.

More information

Topcon. The Leading Provider of Optical and Positioning Solutions

Topcon. The Leading Provider of Optical and Positioning Solutions Topcon The Leading Provider of Optical and Positioning Solutions Topcon Founded in 1932 Major shareholder: Toshiba Topcon business units: Topcon Positioning Systems Topcon Medical Topcon Industrial & Optics

More information

Diagnostic Trouble Code (DTC) List

Diagnostic Trouble Code (DTC) List Diagnostic Trouble Code (DTC) List The following trouble codes may be displayed by the Hawkeye nozzle control system and should help the operator to identify and correct issues with system during field

More information

Module 13 Rate-controller functions and settings Getting the best out of the functions available

Module 13 Rate-controller functions and settings Getting the best out of the functions available SPRAY APPLICATION MANUAL FOR GRAIN GROWERS Module 13 Rate-controller functions and settings Getting the best out of the functions available Graham Betts and Bill Gordon PAGE 2 Key points A rate controller

More information

SENTRY ISOBUS Tip Flow Monitor. Software Version 1.00

SENTRY ISOBUS Tip Flow Monitor. Software Version 1.00 SENTRY 6141 U S E R M A N U A L ISOBUS Tip Flow Monitor Software Version 1.00 Copyrights 2016 TeeJet Technologies. All rights reserved. No part of this document or the computer programs described in it

More information

Display Quick Reference Guide

Display Quick Reference Guide Display Quick Reference Setup Summary Universal Terminal Camera Operating Configuration Selection Tillage Planting Application Harvest Water Management Guidance Case IH MX 290, 24r Equipment Name Vehicle

More information

Population pre-def ned Every Row Population. For other pre-def ned are made to the system or if options are added to the base planter.

Population pre-def ned Every Row Population. For other pre-def ned are made to the system or if options are added to the base planter. The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference Operar s manual for installation

More information

Optimizing and Calibrating Sprayers

Optimizing and Calibrating Sprayers Field: Agroproduction Optimizing and Calibrating Sprayers content Author: Dr. Fatih BARUTÇU 2017 Boosting Adult System Education In Agriculture - AGRI BASE Erasmus+ K2 Action Strategic Partnership AGRIBASE.

More information

APPLICATION EQUIPMENT

APPLICATION EQUIPMENT C 3 H A P TE R APPLICATION EQUIPMENT LEARNING OBJECTIVES After completely studying this chapter, you should: Know the various pesticide application methods and the factors that influence your choice of

More information

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro STEP 1: Pre-Programming Preparation: The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference

More information

Quick Setup Guide for IntelliAg Model YP Air Pro

Quick Setup Guide for IntelliAg Model YP Air Pro STEP 1: Pre-Programming Preparation: The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference

More information

Boom Sprayer Calibration

Boom Sprayer Calibration www.stma.org Boom Sprayer Calibration A tractor- or utility vehicle-mounted boom sprayer applies fertilizers and pesticides to large turfgrass areas. Materials are mixed and continuously agitated in a

More information

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt Note: Indented items indicate parts included in an assembly listed above. Part Name/Description Part Number Quantity Direct Command Kit 4100514 1 Installation Instructions 2005690 1 CAN Y-Splice 4000137

More information

Calibration of herbicide sprayers

Calibration of herbicide sprayers Calibration of herbicide sprayers Guy Kyser, Plant Sciences Department, UC Davis Broadcast applications Directed treatments Why calibrate? Underapplication Overapplication Broadcast application - Usually

More information

CONTENTS 1.0 INTRODUCTION SAFETY... 5

CONTENTS 1.0 INTRODUCTION SAFETY... 5 Contents CONTENTS 1.0 INTRODUCTION........................... 3 2.0 SAFETY.................................. 5 3.0 SETUP................................... 7 AccuShot System Screen ICON Description.....

More information

System Background and Operation

System Background and Operation Pty Limited 1/48 Racecourse Road RUTHERFORD NSW 2320 Telephone: (02) 4932 0111 Facsimile: (02) 4932 0222 E-mail:hyden@hydeneng.com.au ABN: 17 129 010 902 ENVIROSPRAY Manual Manual Number: 06500976A Manual

More information

2. AGRICULTURAL CROP SPRAYERS

2. AGRICULTURAL CROP SPRAYERS 2. AGRICULTURAL CROP SPRAYERS Introduction A sprayer is often used to apply different spray materials, such as pre-emergent and postemergence herbicides, insecticides and fungicides. A change of nozzles

More information

SECTION II - SPRAYER CALIBRATION

SECTION II - SPRAYER CALIBRATION SECTION II - SPRAYER CALIBRATION Proper sprayer calibration is an extremely important step in the application of herbicides. Often, sprayers are not calibrated properly, which results in poor weed control

More information

All machines one language

All machines one language All machines one language Soil tillage Electronics Sowing Intelligent crop production F ertilisin g El e c t r o n ic s Pla nt prote ctio n AMATRON + is the universal operator platform for all my AMAZONE

More information

SureFire Drives and Harnesses for use with John Deere Dry Rate Controller

SureFire Drives and Harnesses for use with John Deere Dry Rate Controller 396-001640 SureFire Drives and Harnesses for use with John Deere Dry Rate Controller & SureFire Dry Fertilizer Control Components 396-001640 John Deere Rate Controller Dry Instructions Page 1 02/23/2012

More information

Sidekick Pro ICD 1 to 40 oz./ min and 5 to 200 oz/min Installation and Operation Manual. P/N Rev. B 8/17/16 E28277

Sidekick Pro ICD 1 to 40 oz./ min and 5 to 200 oz/min Installation and Operation Manual. P/N Rev. B 8/17/16 E28277 Sidekick Pro ICD 1 to 40 oz./ min and 5 to 200 oz/min Installation and Operation Manual P/N 016-0171-605 Rev. B 8/17/16 E28277 Copyright 2016 Disclaimer While every effort has been made to ensure the accuracy

More information

Quick Setup Guide for IntelliAg Model YP

Quick Setup Guide for IntelliAg Model YP STEP 1: Pre-Programming Preparation: Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings. If errs are detected (e.g., failed senss,

More information

& PumpRight for PWM Control. Maximum Pump Flow and Application Rates. Max Flow GPM

& PumpRight for PWM Control. Maximum Pump Flow and Application Rates. Max Flow GPM 396-001070 PumpRight Fertilizer System for John Deere GS2 2600 & GS3 2630 & PumpRight for PWM Control Maximum Pump Flow and Application Rates Number of Diaphragms Max Flow GPM Max GPA on 40 at 6 MPH Max

More information

SharpShooter With Rate Sync for Turf

SharpShooter With Rate Sync for Turf SharpShooter With Rate Sync for Turf 75 40 Actual (psi) 40 Target (psi) Run Duty Cycle (%) Run/Hold Operator and Maintenance Manual APPLICATION SYSTEMS FOR PROFESSIONALS www.capstanag.com How Can We Help?

More information

TASC-6100 LIQUID/GRANULAR APPLICATION CONTROL SYSTEM USER GUIDE PN R2 Software Version 1.30

TASC-6100 LIQUID/GRANULAR APPLICATION CONTROL SYSTEM USER GUIDE PN R2 Software Version 1.30 Alt.-Rate Standard Rate OFF MIDWEST TECHNOLOGIES, INC. TASC-6100 LIQUID/GRANULAR APPLICATION CONTROL SYSTEM USER GUIDE PN - Software Version 1.30 MPH MID-TECH ON OPERATE INC. OFF SET- UP DEC. %Rate Product

More information

Quick Setup Guide for IntelliAg Model YP Twin Row

Quick Setup Guide for IntelliAg Model YP Twin Row STEP 1: Pre-Programming Preparation: The Quick Guide assumes the Virtual Terminal, Master Switch, Wking Set Master, Wking Set Member, and all senss have been connected and properly installed. Reference

More information

Hardi. Precision Defined. precision Spray Height Control

Hardi.   Precision Defined. precision Spray Height Control Hardi Precision Defined Spraying Refined precision Spray Height Control NORAC OFFERS a superior product. It s faster, it s accurate and it maintains boom height, making my life easier in the sprayer. -

More information

Endeavor Fertilizer Controler" Electric Pump Fertilizer System for John Deere GS2 with Servo Control

Endeavor Fertilizer Controler Electric Pump Fertilizer System for John Deere GS2 with Servo Control Endeavor Fertilizer Controler" Electric Pump Fertilizer System for John Deere GS with Servo Control We Can Also Interface with These Popular Third Party Controllers: Trimble - EZ Boom & Field IQ Ag Leader

More information

TR 300 ECONOMY TRAILER SPRAYER HAMILTON # 20, BOOMJET #10, BOOM XT & 8 ROW BOOM HYPRO 8 ROLLER PUMP

TR 300 ECONOMY TRAILER SPRAYER HAMILTON # 20, BOOMJET #10, BOOM XT & 8 ROW BOOM HYPRO 8 ROLLER PUMP OWNERS MANUAL TR 300 ECONOMY TRAILER SPRAYER HAMILTON # 20, BOOMJET #10, BOOM XT & 8 ROW BOOM HYPRO 8 ROLLER PUMP TR 300 ECONOMY SPRAYER AG SPRAY EQUIPMENT OWNER S MANUAL Congratulations on purchasing

More information

AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE

AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE where precision meets the soil... AgXcel GX5 Install Guide for Integration into Trimble PO Box 1611 Kearney, NE 68848 877.218.1981 www.agxcel.com where precision meets the soil... AgXcel Integration into

More information

Calibration Worksheet

Calibration Worksheet Calibration Worksheet Boom Sprayer Follow this step-by-step procedure to calibrate a sprayer. All liquid volumes are in litres (L), but you can use either metric or imperial units for distance and area

More information

Spray Height Controller

Spray Height Controller Spray Height Controller UC5 SERVICE MANUAL AGCO North America Printed in Canada Copyright 2013 by NORAC Systems International Inc. Reorder P/N: UC5 SERVICE MANUAL AGCO NA Rev A NOTICE: NORAC Systems International

More information

OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD. PART NUMBER Rev.

OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD. PART NUMBER Rev. 8150 OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD PART NUMBER 393-000-015 Rev. C Table of Contents 1 TABLE OF TITLE CONTENTS 393-000-015

More information

MICRONAIR SPRAY EQUIPMENT IN FORESTRY

MICRONAIR SPRAY EQUIPMENT IN FORESTRY MICRONAIR SPRAY EQUIPMENT IN FORESTRY Micron Sprayers Limited UK based and owned Established 45 years Inventor of CDA using rotary atomisers 50 employees Sales to over 90 countries Micronair Division on

More information

CALIBRATION LEARNING OBJECTIVES

CALIBRATION LEARNING OBJECTIVES C H A P TE R 4 CALIBRATION LEARNING OBJECTIVES After completely studying this chapter, you should: Understand the purpose of calibration and why it is an essential process. Know the basic tools needed

More information

Equipment CHAPTER 21

Equipment CHAPTER 21 Equipment CHAPTER 21 Learning Objectives Understand and be able to describe application methods covered in this chapter Be able to describe components of each (i.e. nozzles for sprayers), Know how to select

More information

4.1 Flow Rate Verification and Adjustment

4.1 Flow Rate Verification and Adjustment 4.1 Flow Rate Verification and Adjustment Once the pressure verification is complete (see Chapter 3), the gas flow rate should be verified. Accurate gas flow through the nozzle is critical for achieving

More information

Sprayer/Spreader Control Systems

Sprayer/Spreader Control Systems Sprayer/Spreader Control Systems Land Manager Operator's Troubleshooting Manual Table of Contents Topic 1 - Common Operating Questions... 1 Anhydrous System... 1 Granular System... 2 Liquid System...

More information

Creating intelligent technologies for land and water based industries

Creating intelligent technologies for land and water based industries Creating intelligent technologies for land and water based industries Summary ISO standards ASABE and ASTM standards (US) Protocols What is missing for helping assure our data from one country can be considered

More information

Gresen GRS32 Calibration (also see the MnDOT Salt and Sander Calibration Guide for general calibration reference)

Gresen GRS32 Calibration (also see the MnDOT Salt and Sander Calibration Guide for general calibration reference) Gresen GRS32 Calibration (also see the MnDOT Salt and Sander Calibration Guide for general calibration reference) 12/21/2009 Page 1 Gresen Calibration Guide for Mn/DOT by EVS Gresen GRS32 Calibration Table

More information

Calibrating Chemical Application Equipment

Calibrating Chemical Application Equipment Calibrating Chemical Application Equipment PURPOSE To determine if the proper amount of chemical is being applied, the operator must measure the output of the application equipment. This technique is known

More information

Calibrating. Pesticide. Application. Ground. Equipment

Calibrating. Pesticide. Application. Ground. Equipment L-5304 6-00 Calibrating Pesticide Application Ground Equipment Bryan Shaw Assistant Professor and Extension Agricultural Engineering Specialist, The Texas A&M University System. Calibrating Pesticide Application

More information

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro STEP 1: Pre-Programming Preparation: Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings. If errors are detected (e.g., failed

More information

Calibration of Chemical Applicators Used in Vegetables1

Calibration of Chemical Applicators Used in Vegetables1 HS12 Calibration of Chemical Applicators Used in Vegetables1 M. R. Miller and P. J. Dittmar2 includes information about calibration to help growers properly apply pesticides. Definition of Terms GPA: Gallons

More information

MI0559A OXY-BEVEL OPERATIONS MANUAL: Oxy-fuel contouring beveling head with manual tilt function.

MI0559A OXY-BEVEL OPERATIONS MANUAL: Oxy-fuel contouring beveling head with manual tilt function. Page 1 3/21/2014 MI0559A OXY-BEVEL OPERATIONS MANUAL: Oxy-fuel contouring beveling head with manual tilt function. Torches: There are 5 torches total that make up the beveling system. There are two bevel

More information

a. Remove the jack screw: c. Replace the jack screw. d. Reassemble and adjust the limit switch.

a. Remove the jack screw: c. Replace the jack screw. d. Reassemble and adjust the limit switch. 4.2.3 Drawhead Maintenance Refer to the drawings on page for part names and numbers. 1. Lubricate the jack screw when the grease becomes dirty or dried out. NOTE: Remove the limit switch on the bottom

More information

factsheet Field Sprayer Calibration Introduction Pre-Calibration Checklist Using a Calibration Bottle

factsheet Field Sprayer Calibration Introduction Pre-Calibration Checklist Using a Calibration Bottle Field Sprayer Calibration Introduction It is important to properly calibrate your sprayer for maximum performance. Improper spray application can be costly in terms of poor pest control, crop injury and

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

Calibration of Herbicide Applicators 1

Calibration of Herbicide Applicators 1 SS-AGR-102 Calibration of Herbicide Applicators 1 R. Cromwell, J. A. Tredaway, and D. L. Colvin 2 There are two primary reasons to calibrate a sprayer: pressure would have to be increased four times to

More information

844-E Sprayer Control. Installation, Programming and Operating

844-E Sprayer Control. Installation, Programming and Operating 844-E Sprayer Control User MANUAL Installation, Programming and Operating Table of Contents Chapter 1 - introduction 1 Chapter 2 - Mounting Sprayer Components 2 Pressure Regulator in Bypass Mode... 2 Pressure

More information

ACCURACY. PRODUCTIVITY. RELIABILITY.

ACCURACY. PRODUCTIVITY. RELIABILITY. ACCURACY. PRODUCTIVITY. RELIABILITY. Precision Air 4955 cart. YOU ASKED FOR IT. WE BUILT IT. Introducing the new Case IH Precision Air 5 series air carts with new features and systems designed to meet

More information

VisiFlo Hollow Cone Spray Tips

VisiFlo Hollow Cone Spray Tips VisiFlo Hollow Cone Tips See selection guide on page 5 for for ConeJet tips. n VisiFlo color-coded versions consist of stainless steel or ceramic orifice in a polypropylene body. Maximum operating pressure

More information

SCS 440 SERIAL INTERFACE INSTALLATION AND SERVICE MANUAL

SCS 440 SERIAL INTERFACE INSTALLATION AND SERVICE MANUAL SCS 440 SERIAL INTERFACE INSTALLATION AND SERVICE MANUAL N O T I C E The use of the suspension type fertilizers and lime slurries will significantly reduce the life of the plastic parts in the Flow Meter

More information

Spray Height Controller

Spray Height Controller Spray Height Controller UC5 SERVICE MANUAL 2012 Printed in Canada Copyright 2012 by NORAC Systems International Inc. Reorder P/N: UC5 SERVICE MANUAL 2012 Rev B NOTICE: NORAC Systems International Inc.

More information

Air-Cooled Eddy Current Engine Dynamometers

Air-Cooled Eddy Current Engine Dynamometers Air-Cooled Eddy Current Engine Dynamometers Mustang s ED Series Air-Cooled Engine Dynamometers are the answer for ED Series Engine due Dynamometers most engine Air-Cooled testing applications to their

More information

Tanktronic Installation Guide

Tanktronic Installation Guide Tanktronic Installation Guide Notes keraflo.co.uk 2 Contents Introduction... 4 Quick Start... 5 Levels... 8 Valves... 10 - Tanktronic Servo Ceramic Valve (SCV)... 10 - Tanktronic Control Valve... 13 -

More information

Seed Rate Controller Operators Manual

Seed Rate Controller Operators Manual Seed Rate Controller Operators Manual Part Number A2678 Rev. 1.41 Copyright Topcon Precision Agriculture December, 2007 All contents in this manual are copyrighted by Topcon. All rights reserved. The information

More information

Operating instructions

Operating instructions Operating instructions Sprayer Controller Midi Last update: V3.20120222 30322321-02-US Read and follow this operating instructions. Keep this operating instructions for future reference. Legal notice Document

More information

Pneumatic control units. SeleJet Pneumatic on/off and control valves

Pneumatic control units. SeleJet Pneumatic on/off and control valves SeleJet Pneumatic on/off and control valves NEW SeleJet NEW Quick fit nozzle holders for individual nozzle shut-off with flow-stop Four-way or two-way nozzle holders with individual pneumatic nozzle shut-off.

More information

Leaders in precision application components, control system technology, and application data management.

Leaders in precision application components, control system technology, and application data management. Catalog 51-M Leaders in precision application components, control system technology, and application data management. www.teejet.com Table of Contents Selection Guide TeeJet Broadcast Nozzle Selection

More information

MEYCO ME3. Concrete Spraying Mobile for medium sized tunnels

MEYCO ME3. Concrete Spraying Mobile for medium sized tunnels MEYCO ME3 Concrete Spraying Mobile for medium sized tunnels VERSATILE CONCRETE SPRAYING APPLICATION EXPERTISE UNIFIED FOR HIGH QUALITY, ECONOMICAL AND SAFE APPLICATION OF SPRAYED CONCRETE. MAIN BENEFITS

More information

John Deere AutoTrac Control ler- Reichhardt PFP11784

John Deere AutoTrac Control ler- Reichhardt PFP11784 John Deere AutoTrac Control ler- Reichhardt PFP11784 About This Document This User Guide will help you learn how to perform common tasks with your John Deere AutoTrac Controller - Reichhardt. It is a supplement

More information

Ag Leader Technology InSight/Ag Leader Integra. OptRx OptRx Remote Sensor Kit

Ag Leader Technology InSight/Ag Leader Integra. OptRx OptRx Remote Sensor Kit : Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Master Module Kit 4100804 1 Master Module 4001821 1 Cable - Master 4001904-10 1 Cable - CAN

More information

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES TRIMOD HE UPS MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES TRIMOD HE HIGH performance HIGH efficiency LOW environmental impact DEVELOPMENTS

More information

SPRAYER PRICE LIST 2016

SPRAYER PRICE LIST 2016 SPRAYER PRICE LIST 2016 TRACTOR MOUNTED SPRAYERS ECO MEC & MEC BDM 200ltr to 1300ltr Total Emptying Tank Single nozzle bodies Manual Control Unit Diaphragm Pump (2cyl 70lt/min up to 600lt, 3cyl 135lt/min

More information

Warm Melt Supply Systems. For warm melt materials and temperature conditioning applications

Warm Melt Supply Systems. For warm melt materials and temperature conditioning applications Warm Melt Supply Systems For warm melt materials and temperature conditioning applications Advanced Technology with a Modular Approach Precision temperature control Designed specifically for warm melt

More information

Free-Standing Bulk Storage Tanks (Hoops Required)

Free-Standing Bulk Storage Tanks (Hoops Required) December 2014 Free-Standing Bulk Storage Tanks (Hoops Required) PART # CAPACITY WEIGHT DIMENSIONS LID FITTING PRICING FS1005-48 1005 Gallon 342 48 x 130 16" 2" $1,004.47 FS1005-HP 1005 Gal Hoops Set of

More information

Technical Training GEN I

Technical Training GEN I Technical Training GEN I Air Flow & Hose Routing The centerline of the goose neck arms hitch point (center of balls or knuckle hitch bolts) to the furthest back part of the row unit or bar attachment can

More information

Crankcase scavenging.

Crankcase scavenging. Software for engine simulation and optimization www.diesel-rk.bmstu.ru The full cycle thermodynamic engine simulation software DIESEL-RK is designed for simulating and optimizing working processes of two-

More information

WP8: Engine Integrated SCR and combined SCR and DPF

WP8: Engine Integrated SCR and combined SCR and DPF WP8: Engine Integrated SCR and combined SCR and DPF Objectives Engine Integrated SCR Investigation of High Pressure SCR process; injection, mixing, decomposition and flow distribution with the aim of making

More information

Calibrating Boom Sprayers

Calibrating Boom Sprayers Calibrating Boom Sprayers John W. Slocombe, reviewer (2014), Professor, Ag and Forage Machinery Safety, Kansas State University Robert E. Wolf, Extension Specialist, Biological and Agricultural Engineering,

More information

Presented by. Navistar Education 2015

Presented by. Navistar Education 2015 Presented by Navistar Education 2015 1.2 Overview This course is intended to provide parts specialists with a description of Diesel Exhaust Fluid, or DEF, part number configuration, ordering and distribution

More information

Fine Tuning a Sprayer with Ounce Calibration Method

Fine Tuning a Sprayer with Ounce Calibration Method Publication 442-453 Fine Tuning a Sprayer with Ounce Calibration Method Robert Grisso, Extension Engineer, Biological Systems Engineering Department, Virginia Tech Mike Weaver, Extension Pesticide Programs

More information

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor Product manual Oil Streak Sensor INTRODUCTION Oil streak sensors are designed to detect traces of oil travelling through air tubes, down to flows as low as 5mm 3 /min. The product utilizes a master and

More information

AutoGlideXR Installation Procedures for Bestway Sprayer (Can be used for universal fitment)

AutoGlideXR Installation Procedures for Bestway Sprayer (Can be used for universal fitment) AutoGlideXR Installation Procedures for Bestway Sprayer (Can be used for universal fitment) AutoGlideXR systems ship 1 of 4 ways. In figure 1 you will see a base 2-sensor (70802XR) system with all the

More information

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016 PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS v1.1 Revised Table of Contents 1 Common Alarms and Warnings... 1 2 Common Issues... 6 2.1 Communication problems... 6 2.1.1 Controller communication

More information

TOPCON APOLLO ISOBUS SEEDER CONTROLLER OPERATOR S MANUAL

TOPCON APOLLO ISOBUS SEEDER CONTROLLER OPERATOR S MANUAL TOPCON APOLLO ISOBUS SEEDER CONTROLLER OPERATOR S MANUAL Apollo Serial No: Software Verson: Software Upgrade Log Date Version Notes Simplicity Australia Part No 198515318 Apollo ISOBUS UT Seeder Operator

More information

PRECISION APPLICATION

PRECISION APPLICATION PRECISION APPLICATION NUTRI-PRO SPRAYERS www.greatplainsag.com Great Plains Precision Application implements ensure optimal crop performance with the precise placement of nutrient, weed, and pest control

More information

BE 20 IMI Cornelius Orange Juice Dispenser Model Quest Elite QLT 2000

BE 20 IMI Cornelius Orange Juice Dispenser Model Quest Elite QLT 2000 BEVERAGE EQUIPMENT BE 20 IMI Cornelius Orange Juice Dispenser Model Quest Elite QLT 2000 Daily maintenance tasks BE 20 D1 Flush orange juice system Weekly maintenance tasks BE 20 W1 Sanitize orange juice

More information

TomTom WEBFLEET Contents. Let s drive business TM. Release note

TomTom WEBFLEET Contents. Let s drive business TM. Release note TomTom WEBFLEET 2.17 Release note Contents Extended WEBFLEET Reporting 2 Reporting Diagnostic Trouble Codes 3 Security features 5 Invoice only interface 7 Default trip mode 8 Navigation map information

More information

Advanced User Manual

Advanced User Manual Advanced User Manual Banks SpeedBrake For use with Palm Tungsten E2 2004-2005 Chevy/GMC 6.6L (LLY) Turbo-Diesel Pickup THIS MANUAL IS FOR USE WITH KITS 55419 & 55421 Gale Banks Engineering 546 Duggan Avenue

More information

How important is Calibrating your sprayer on a regular basis?

How important is Calibrating your sprayer on a regular basis? Sprayer Calibration How important is Calibrating your sprayer on a regular basis? If you spend $50,000.00 dollars per year on chemical! We divide that cost by the number of nozzles on your sprayer. For

More information

BOOM HEIGHT CONTROL PRECISION DEFINED SPRAYING REFINED

BOOM HEIGHT CONTROL PRECISION DEFINED SPRAYING REFINED WWW.NORAC.CA BOOM HEIGHT CONTROL PRECISION DEFINED SPRAYING REFINED The NORAC system is very reliable. It has auto-everything and I don t have to worry about a thing. - Blair Gerein NORAC OFFERS BEST IN

More information

Spray Tip Guide HIGH QUALITY SPRAY TIPS FOR EVERY SPRAYING NEED. w w w. h y p r o p u m p s. c o m

Spray Tip Guide HIGH QUALITY SPRAY TIPS FOR EVERY SPRAYING NEED. w w w. h y p r o p u m p s. c o m Spray Tip Guide HIGH QUALITY SPRAY TIPS FOR EVERY SPRAYING NEED w w w. h y p r o p u m p s. c o m Table of Contents Selecting the Right Spray Tip....................................2-4 Spray Tip Maintenance..........................................5

More information

Calibration & Operation Manual

Calibration & Operation Manual Calibration & Operation Manual ISO AutoBoom Software Version 6.0 & Newer Disclaimer While every effort has been made to ensure the accuracy of this document, Raven Industries assumes no responsibility

More information

INSTALLATION INSTRUCTIONS ALL JOHN DEERE SYSTEMS

INSTALLATION INSTRUCTIONS ALL JOHN DEERE SYSTEMS 2 3 6 7 1 REAR 4 5 HELPFUL TOOLS Drill and Drill Bit for 3/8 Bolt 3/8 Ratchet with 9/16 Socket NEED HELP? Call our Product Support team at 888-512-4890. STEP 1 PREPARE BASE UNIT Slide the boom height base

More information

Ohio State University Extension. Boom Sprayer Calibration, AEX Food, Agricultural and Biological Engineering

Ohio State University Extension. Boom Sprayer Calibration, AEX Food, Agricultural and Biological Engineering Page 1 of 7 Ohio State University Extension Food, Agricultural and Biological Engineering 590 Woody Hayes Dr., Columbus, Ohio 43210 Boom Sprayer Calibration AEX-520-92 H. Erdal Ozkan Professor and Extension

More information

DICKEY-john Sales DICKEY-john Technical Support

DICKEY-john Sales DICKEY-john Technical Support 5200 DICKEY-john Road Auburn, IL 62615 www.dickey-john.com DICKEY-john Sales 800-637-2952 agsales@dickey-john.com DICKEY-john Technical Support 800-637-3302 service@dickey-john.com 2008 DICKEY-john Corporation

More information

834 Sprayer Control L2.12 User Guide R1

834 Sprayer Control L2.12 User Guide R1 834 Sprayer Control L2.12 User Guide 98-70019-R1 TECHNOLOGES Table of Contents 834 Sprayer Control Programming Guidelines 3 Start 4 System Setup Mode 5 ensity 5 Speed Sensor Calibration 6 Auto Calibration

More information

Installation and Operation Manual Flo-Sense NH 3 Flow Indicator System

Installation and Operation Manual Flo-Sense NH 3 Flow Indicator System Installation and Operation Manual Flo-Sense NH 3 Flow Indicator System September 2013 Form FVC098 - Rev 02 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER. 1. Contact with

More information

Air Spray Proportioning Valve

Air Spray Proportioning Valve Instruction Sheet P/N Air Spray Proportioning Valve. Installation The air spray proportioning valve provides close regulation of air spray characteristics for air spray versions of the Pro-Flo dispensing

More information

Web/SNMP Management Card Event Support Chart

Web/SNMP Management Card Event Support Chart Web/SNMP Management Card Event Support Chart 0x0001 System: Coldstart. 0x0002 System: Warmstart. 0x0003 System: SNMP configuration change. System: Detected an unauthorized user attempting to access the

More information

T ls T ys. 120 Foot Boyd Aluminum Booms on a 3 Point Hitch Bob Tail Center Rack (Photo: Northern Equipment)

T ls T ys. 120 Foot Boyd Aluminum Booms on a 3 Point Hitch Bob Tail Center Rack (Photo: Northern Equipment) T ls T ys 120 Foot Boyd Aluminum Booms on a 3 Point Hitch Bob Tail Center Rack (Photo: Northern Equipment) Dr. Jason Deveau OMAFRA Application Technology Specialist Winter 2015 Working to reduce pesticide

More information

BOOMLESS NOZZLES FIELDJET TFW TURBO FLOODJET BOOMLESS NOZZLES WITH EXTRA-WIDE FLAT SPRAY PROJECTION

BOOMLESS NOZZLES FIELDJET TFW TURBO FLOODJET BOOMLESS NOZZLES WITH EXTRA-WIDE FLAT SPRAY PROJECTION BOOMLESS NOZZLES FIELDJET BOOMLESS NOZZLES WITH EXTRAWIDE FLAT SPRAY PROJECTION The KLC Fieldjet nozzle is typically used to spray areas not accessible with a boom sprayer. Its onepiece design projects

More information